9f20 ver. 9/28/2020 appendix
TRANSCRIPT
9F20 Ver. 9/28/2020 Based on the 2020 BCNYS, FCNYS, PCNYS, ECCCNYS
APPENDIX
Student Exercises and Supplemental Material Commercial Building Plan Review
NEW YORK STATE, DEPARTMENT OF STATE Division of Building Standards and Codes One Commerce Plaza 99 Washington Avenue Albany, NY 12231-0001 Phone: (518) 474-4073 Fax: (518) 474-5788 www.dos.ny.gov
Table of Contents Building Permit Application Lesson 4 - Rated wall UL design Lesson 4 - Rated floor ceiling assembly UL design Lesson 4 - Rated tube steel UL design Lesson 4 - Elevator exercise Lesson 7 - Fire Alarm component exercise Lesson 6 - Roof shingles. manufacturer’s information Lesson 6: Structural load documentation Lesson 6: Seismic documentation Lesson 6 - Structural Detail - masonry Lesson 8 - Plumbing fixture count exercise Lesson 8: Plumbing supply size exercise Lesson 8: Plumbing drainage size exercise Lesson 8 - Plumbing plan review worksheets Commercial Occupancies Review Guide Commercial Documentation Review Guide Commercial Documentation Review Guide - structural Commercial Documentation Review Guide - energy
Page Appendix 2 Appendix 3 Appendix 4 Appendix 5 Appendix 6 Appendix 7 Appendix 11-12 Appendix 13 Appendix 14 Appendix 15 Appendix 16 Appendix 16 Appendix 17-18 Appendix 19 Appendix 20 Appendix 21 Appendix 22
Appendix
Appendix - 2
Appendix
Appendix - 3
Appendix
Appendix - 4
Appendix
Appendix - 5
Appendix
Lesson 4 - Elevator Requirements : Chapter 30
Using Chapter 30 and the information on the elevator found on sheet A5 – 1, list those items that should be included in the proposed building. Be sure to site the appropriate section and be prepared to support your conclusions.
1. _______________________________________
2.
_________________________________________
3.
_________________________________________
4.
_________________________________________
5.
_________________________________________
6.
_________________________________________
Appendix - 6
Appendix
Appendix - 7
Lesson 7 - Fire Protection Equipment Fire Alarm Components
Using Sheets E-4, E-6 and E-7 identify and locate the following. Give sheet number and room name:
1. Fire Alarm control panel: __________________________
2. Fire Alarm sub-control panel: _______________________
3. Duct mount smoke detector: _______________________
4. Tamper switch: __________________________________
5. Wall mount strobe: _______________________________
6. Annunciator panel: _______________________________
Appendix
Appendix - 8
Appendix
Structural Documentation
Appendix - 19
Appendix
Structural Documentation
Appendix - 110
Chapter 16: Design submittals
Topic Information required
Designer documentation
Local conditions
1(a) 1603.1.1 Floor Live
Uniform distributed
Concentrated
Impact
1st floor – 100 psf 2nd floor – 80 psf
3rd floor – 50 psf
Concentrated – all
3,000 psf
Table 1607.1
1607.9
1(b) 1603.1.2
Roof live
None
1(c) 1603.1.3
Roof snow
Ground snow Pg
Flat roof Pf
Pf = .7 PgCeICt
Exosure Ce
Importance I
Thermal Ct Drift surcharge load Pd
Width of snow drift
45 psf
45 psf
Fig 1608.2
ASCE 7 Sec. 7.3
Table 7-2 Table 7-4 Table 7-3
Appendix
Structural Documentation
Appendix - 12
Chapter 16: Design submittals
Topic Information required Designer documentation
Local conditions
1(d) 1603.1.4
Wind loads Wind speed Vult
Vasd
Risk Category
Importance factor Exposure
Surface roughness
Exposure categories Internal pressure
Components, Cladding
90 mph fastest mile
Category 2
None Manufacturer’s inst’
Fig 1609 Table 1604.5
ASCE 7, Table 6-1
1609.4
1609.4.2
1609.4.3
1609.6.4.4.1
Table 1613.2.5 (1) & (2)
Appendix
Structural Documentation
Appendix - 13
Chapter 21: Masonry
Appendix
Structural Documentation
Appendix - 14
Appendix
Appendix - 15
Lesson 8 - Plumbing Plan Review Required Plumbing Fixtures
Using the provided floor plans and the Plumbing Code, (Table 403.1 ) determine if there are enough fixtures provided in the building.
Fixture Type Business
Water Closet
Male
Female
Lavatories
Male
Female
Drinking Fountains
Service sink
Appendix
Student Activity Table 604.5 Plumbing Supply Size
Code plans
Water closet ____ ____
Lavatory ____ ____
Drinking fountain ____ ____
Service sink ____ ____
Shower ____ ____
Student Activity
DFU count Table 709.1
Code Total per branch
Water closet ____ ______
Lavatory ____ drain size
Drinking fountain ____ _______
Service sink ____ vent size
Shower ____ _______
Appendix - 16
Appendix
Lesson 8 - Plumbing Plan Review Drainage Pipe sizing
Example: Drainage stack #1 - Using Sections 709 and 710 of the Plumbing Code and Page P – 4 of the assigned plans, we will determine if the proposed drainage piping is adequate.
Appendix - 17
Appendix
Lesson 8 - Plumbing Plan Review Drainage Pipe sizing
Using Sections 709 and 710 of the Plumbing Code and Page P – 4 of the assigned plans, determine if the proposed drainage piping is adequate for the building drain.
Appendix - 18
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 1 of 11
NYS UNIFORM FIRE PREVENTION AND BUILDING CODE 2020 BCNYS COMMERCIAL OCCUPANCIES REVIEW CHECKLIST 2020 FCNYS 2020 PCNYS Owner/Project: 2020 MCNYS Building location: 2020 FGCNYS
Date: 2020 ECCCNYS Reviewer:
No Topic Section Required or Allowed Actual
1 Occupancy
Classification Use
B-302
2 Type of Construction
Materials Comb/Non
Fire Resistance
Structural Frame
Bearing walls
Floors
Roof construction
B-602
B-Table 601
3 Building Height & Area
Height (feet)
Height (story)
Allowable area (square feet)
B-503
B-Table 504.3
B-Table 504.4
B-Table 506.2
Cumulative max
Max per story
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 2 of 11
No Topic Section Required or Allowed Actual
4 Area Determination
Single occupancy, 1 story
Mixed occupancy, 1 story
Single occupancy, Multiple story
Multiple occupancy, Multiple Story
Mixed Occupancy
Non-separated
Separated uses
B-506.2.1
Equation 5-1
B-506.2.2
Equation 5-1
B-506.2.3
Equation 5-2
B-506.2.4
Equation 5-3
B-508.3 B-508.4
If no frontage increase, use tabular values At Aa = At + (NS × If)
Aa = At + (NS × If)
Aa = [At + (NS × If)] x Sa
Aa = [At + (NS × If)]
5 Area Modifications Area increase formulas Frontage Increase
(P) perimeter of building (F) frontage of building (W) average yard width
Unlimited area
Total Area Allowed
B-506.3.3
Equation 5-5
Equation 5-4
B- 507
If = [F/P - 0.25]W/30 Min 20' Max 30' W = (L1 x W1 + L2 x W2 + L3 …
6 Multiple Use Building
Incidental Use Areas
Mixed Occupancy Accessory Occupancy
Non-separated
Separated Uses Rating required
B-509 B-Table 509
B-508.2 B-508.2.3
B-508.3
B-508.4 B-Table 508.4
Separate/Protect
< 10%, no effect on area
Most restrictive height and building area
Sum of Ratios < 1
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 3 of 11
No Topic Section Required or Allowed Actual
7 Location on Property
Fire Separation Distance Wall rating
Exterior Wall Openings
B-Table 602
B-Table 705.8
8 Interior Finishes Wall and Ceiling
Textiles Wall Ceiling
Floor finishes
B-803.1
B-Table 803.13
B- 803.1.2
B- 803.1.3
B-804
9 Interior Environment
Ventilation
Light
Min. Rm. Dimensions
Min. Ceiling Height
B-1202.1
B-1204.1
B-1207.1
B-1207.2
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 4 of 11
No Topic Section Required or Allowed Actual
10 Atriums
Sprinkler Protection
Fire Alarm System
Smoke Control
Enclosure
Interior Finish
Travel Distance
Interior exit stairways
B- 404
B- 404.3
B- 404.4
B- 404.5
B- 404.6
B- 404.8
B-404.9
B-404.10
Class B min
Max 50% through Atrium
11 Fire Rated Construction Exterior Walls Projections
Fire Walls Separate Buildings Party Wall
Ratings
Fire Barrier Fire Areas Supporting Construction
Fire Partition
Smoke Barriers
Shaft Enclosure Fire rating Penetrations
Opening Protectives
Concealed Spaces Fire Blocking Draft Stopping
B-705 B-Tbl 705.2
B-706 B-706.1 B-706.1.1 B-Table 706.4
B-707 B-Tbl 707.3.10 B-707.5.1
B-708
B-709
B-713 B-713.4
B-714
B-Table 716.1(2)
B-718
B-718.2 B-718.3 Floors B-718.4 Attics
Min of barrier rating
Min 1 hr
< 4 stories 1 hr min 4 or more stories 2 hr min
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 5 of 11
No Topic Section Required or Allowed Actual
12 Fire Protection Equipment Supervisory Service
Sprinkler Systems Where required
Alternate Extinguishing Systems Commercial cooking
Standpipe Systems
Fire Extinguishers
Fire Alarm Systems Where required
Smoke Alarms
Occupant notification
Visible Alarms
Installation/Monitoring
Smoke Control System
Smoke and Heat Removal Fire Department Connections Carbon Monoxide Detection
B-901.6
F/B-903 F/B-903.2
F/B-904 F/B-904.12 F-607
F/B-905
F/B-906
F/B-907 F/B-907.2
F/B-907.2.10
F/B- 907.5
F/B-907.5.2.3
F/B-907.6
F/B-909
F/B-910 F/B-912 F/B-915
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 6 of 11
No Topic Section Required or Allowed Actual
13 (a)
Means of Egress
Ceiling Height
Occupant Load
Egress Width (per occupant)
Number of Exits Spaces with one Min exits per story
Egress Illumination Emergency Power Exit Signs - where Emergency Power
B-1003.2
B-Tbl 1004.5
B- 1005.2 B- 1005.3
B- 1006 B- Tbl 1006.2.1 B- Tbl 1006.3.2
B- 1008.2 B-1008.3 B- 1013.1 B- 1013.6.3
13 (b)
Egress Components Doors Size Swing Operation Hardware Panic / Fire Hardware
Stairways Width Headroom Tread /Riser Landings Vertical Rise
Handrails
Luminous Egress marking
B- 1010.1.1 B- 1010.1.2 B- 1010.1.9 B- 1010.1.9.1 B- 1010.1.10
B- 1011 B-1011.2 B-1011.3 B-1011.5 B- 1011.6 B-1011.8
B-1014
B- 1025 High Rise A, B, E, I-1, M, R1
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 7 of 11
No Topic Section Required or Allowed Actual
13 (c)
Exit Access
Remoteness
Travel Distance
Spaces w/1 Exit
Story w/1 Exit
Corridors
Fire Rating
Width
Dead ends
B-1007.1.1
B- Tbl 1017.2
B-Tbl 1006.2.1
B – Tbl 1006.3.3(2)
B-1020.1
B- Tbl 1020.1
B- Tbl 1020.2
B-1020.4
14 ACCESSIBILITY
Exempt Spaces
Route Multistory exception
Public Entrances
Parking
Access Aisles
Group I
Group R Dwelling/sleeping units
Special Occupancies Other Facilities
Signage
B-1103.2
B-1104.1 B-1104.4 items #1 - 4
B-1105.1
1106.1.1 B-Tbl 1106.1
B-1106.1.1
B-1107.5
B- 1107.6 1107.6.4 B-Tbl 1107.6.1.1
B-1108 B- 1109
B- 1111.1
60% accessible
8’ minimum access aisle
R-4 accessible and type B
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 8 of 11
15 Exterior Wall Water resistive barrier
Vapor retarders
Flashing
Combustible Finishes Min fire separation
Balconies & projections
B-1404.2
B-1404.3
B-1404.4
B-1405.1 B-Tbl 1405.1.1.1.2
B-705.2.3.1
16 Roof Assemblies
Performance Requirements
Gravel/Stone limitation
Installation by Material
Chapter 15
Section 1504
B-1504.8
B-Tab 1504.8
B-1506
17 Structural Documentation – see Commercial Structural Documentation Checklist
18 Special Inspections - see Commercial Structural Documentation Checklist
19 Energy – see Commercial Energy checklist
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 9 of 11
20 Masonry Mortar
Method
Seismic Design Allowable Stress
Strength of Masonry
Empirical Design
Glass Masonry Masonry Fireplaces
Footing / Foundations
Seismic reinforcement
Seismic anchorage
Firebox walls
Firebox dimensions
Hearth and Extension
Fireplace clearance
Fireplace fireblocking
Exterior air
Masonry Heaters
Masonry Chimneys
2103.2
2106 and
2107 and
2108 and
2109 and
2109.1.1
2110 and 2111
2113.2
2111.3
2111.5
2111.6
2111.7
2111.10
2111.12
2111.13
2111.14
2112
2113 2114
Compliance
Ch 7, TMS 402/ACI 530/ASCE 5 2106; Ch 8,TMS 402/ACI 530/ASCE 5 2106; TMS 402/ACI 530/ASCE 5 Appdx A, TMS 402/ACI 530/ASCE 5 Never Risk Category IV structures Never where Vasd >110mph
Ch 13, TMS 402/ACI 530/ASCE 5
Minimum 12” thick, 6” wider than fireplace
SDC C or D SDC E or F
At every floor, ceiling roof line
Min 20” depth; throat min 8” above opening Min 2” combustibles; back 4”
Minimum thickness
required
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 10 of 11
21 Plumbing Code General Requirements Pipe freezing Structural safety Pipe support Tests / inspections
Fixture Count
Water Supply Service Pipe Size Fixture Pipe Size
Pipe Material
Valves required
Sanitary Drainage/Vent DWV Pipe Material Cleanouts Drain Fixture Units Building Drain Sizes
Stack and Branch size Waste vents Size & length
Air Admittance Valves
Storm Drainage
P- 305.4 P-307 P-Tbl 308.5
P-312
P-Tbl 403.1
P-603.1 P-Tbl 604.5 P-Tbl 605.4
P-606.1, 606.2
P-702 P-708 P-Tbl 709. P-Tbl 710.1(1)
P-Tbl 710.1(2)
P-Tbl 906.1
P-918
P-1106
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 11 of 11
22 Mechanical Code Ventilation required Mechanical ventilation
Propane Ventilation
Dryer Exhaust
Kitchen Exhaust Kitchen Hoods Kitchen Make-Up Air Cooking Fire Suppression
Plenums Fire & Smoke Dampers
Combustion Air Chimney / Vents
M-401.2 M-403.2 M- Tbl 403.3.1.1 M-502.9.10 M-504
M-506 M-507 M-508 M-509
M-602 M-607.5
M-701 M-801
R2, R3, R4 req mech
23 Fuel Gas Code
Appliance Location
Combustion Air
Clearance to combustibles
Access
Pipe Material
Shut Off Valves
Chimney Termination
Gas Vent Termination
Vent Termination Location
Clothes Dryer Exhaust
Unvented Room Heater
Cooking Appliances
FG-303
FG-304.1
FG-305.8
FG-306
FG-403
FG-409
FG-503.5.4
FG-Fig. 503.6.5
FG-503.8
FG-614
FG-621 FG-623
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
NYS UNIFORM FIRE PREVENTION AND BUILDING CODE 2020 BCNYS COMMERCIAL OCCUPANCIES REVIEW CHECKLIST 2020 FCNYS 2020 PCNYS Owner/Project: 2020 MCNYS Building location: 2020 FGCNYS
Date: 2020 ECCCNYS
Reviewer:
No Code / item Section Topic Req Actual
1 Building Code B302 Occupancy
Use
1(a) Special Detailed Use B402.3 Covered/Open Malls
Lease plan
1(a) Occupant load increase B1004.5.1 Floor diagram required
1(a) Rooftop assemblies B1504.1.1
B1505.6
B1505.8
B1506
Wind resistance
Asphalt shingles labeled for compliance w/ ASTM7158 or 3161
Fire resistance
Wood shakes bundles labeled with:
-manufacturer
-classification of material
-treating company
Building integrated PV
-listed / labeled fire classification
Materials
-packages bear mfg markings / test info
1(a) Structural Use Commercial structural guide
1(a) Concrete Use Commercial structural guide
Page 1 of 2
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Appendix - 20
No Code / item Section Topic Req Actual
1(a) Steel Use Commercial structural guide
1(a) Wood Use Commercial structural guide
1(a) Masonry Use Commercial structural guide
1(a) Temporary structures B3103.2 Construction documents: -site plan with location, means of egress and occupant load
1(a) Safeguards B3303.1 Construction documents and schedule
2 Plumbing Code P-303.4
P-312.1
P-316.1.2
P-715
P-716.7
3rd party certification
Required Tests
Alternate system submittal
Vacuum drainage system
Pipe bursting post-inspection
3 Mechanical Code
M-301.5
M-301.7
M-312.1
M-403.2
M-407
M-504.8.4.2
M-508.1.2
3rd Party Certification
Listed & Labeled
Heating Load Calculations
Outdoor Air Required
I-2 / Ambulatory care vent
Clothes dryer exhaust – Manuf
Commercial hood air balance
4 Energy code Use Commercial energy code guide
Page 2 of 2
ubmitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate
Page 1 of 8
NYS UNIFORM FIRE PREVENTION AND BUILDING CODE COMMERCIAL DOCUMENTATION REVIEW CHECKLIST- Structural
Owner/Project: Building location: Date: Reviewer: 2020 BCNYS
Topic Information required Designer documentation
Required/Local conditions
1(a) 1603.1.1 Floor Live
Uniform distributed
Concentrated
Impact
Table 1607.1
1607.8
1(b) 1603.1.2 Roof live
1607.13
1(c) 1603.1.3 Roof snow
Ground snow Pg
Flat roof Pf (Pf = .7 PfCeICt) Exposure Ce Importance I Thermal Ct
Drift surcharge load. Pd
Width of snow drift where the sum of Pd & Pf exceeds 20 psf
Fig 1608.2
ASCE 7 Sec. 7.3
Table 7-2 Table 7-4 Table 7-3
1(d) 1603.1.4 Wind loads
Wind speed Vult
Vasd
Risk Category Importance factor I
Exposure Surface roughness Exposure categories Internal pressure Components, Cladding
Fig 1609.3(1) through 1609.3(4) Tab 1604.5 ASCE 7, Tab 6-1
1609.4 1609.4.2 1609.4.3
B- 1609.6.4.4.1
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 2 of 8
Topic Information required Designer documentation
Required/Local conditions
1(e)
Information Required___
1603.1.5 Earthquake design
Ss and S1
Risk Category
Soils/Site Class
Sds and Sd1
Seismic Design Category
Force resisting system
Design base shear
Response coefficient, CS
Response factor(s), R Analysis procedure
Table 1604.5: _____________
Zip __________ Ss ______ S1 ______ SDC per Tables 1613.2.5 (1)&(2) Completed by CEO
Site Sds
Sd1
SDC
I&II III IV
A
B
C
D
E
1(f) Geotechnical
1603.1.6
Design load bearing value of soils
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 3 of 8
Topic Information required Designer documentation
Required/Local conditions
1(g) 1603.1.7
Flood load
1612.3
Flood Hazard Y/N
Elevation lowest floor
Elevation dry
floodproof
High velocity wave
Y/N
Elevation lowest horizontal member
FIRM/FBFM map date
1(h) 1603.1.8
Special Loads
1(i) Special Loads
1603.1.8.1
Rooftop Photovoltaic panel system – dead load
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 4 of 8
Topic Information required Designer documentation
Required/Local conditions
2(a) Special inspections B1703.1
B1703.1.1
B1703.1.2
B1703.1.3
B1703.2
B1703.4
B1703.6
B1703.6.2
B1704.2.1
B1704.3
B1704.5
B1704.6
B1705
Approved Agency: - No conflict of interest - Adequate equipment - Experienced personnel Written approval submitted of required tests / reports Performance of product, material, assembly meets code requirements Evaluation – prefab assembly Necessary test / special inspection records Special inspector qualifications Statement of Special Inspections Submittals to the code official Structural Observations
-Seismic observations -Wind requirements Vasd > 110 mph Required Special Inspections Steel Concrete Masonry Wood Soils Driven deep foundations Cast in place deep foundations Helical Pile foundations Fabricated items Wind resistance Seismic resistance Sprayed fire resistant materials Mastic / Intumescent fire retardant coatings Fire resistant penetrations / joints
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 5 of 8
Topic Information required Designer documentation
Required/Local conditions
2(b) Special Inspections
Approved Agency Written approval Special Inspector Qualifications Spec Insp Statement Spec Insp Statement Wind Seismic Structural Observation Seismic Wind Special Inspection Topic Steel Constr Concrete Constr Masonry Constr Wood Constr Soils Driven Deep Found Cast in Place Found Helical Pile Found Fabricated items Spec Insp for Wind Spec insp for Seismic Testing / Seismic resist Spray Fire Resist Mastic / Intumescent coatings
Ext Insulation / Finish Fire Resist Penetrations/Joints Smoke Control Test
Appliance, equip, system
Applicant
Design professional Design professional
B-1703.1 B-1703.2 B-1704.2.1
B-1704.2.3 B-1704.3 B-1704.3.2 B-1704.3.3
B-1704.6.1 B-1704.6.2
B-1705.2
B-1705.3 B-1705.4 B-1705.5 B-1705.6 B-1705.7 B-1705.8
B-1705.9
B-1705.10 B-1705.11 B-1705.12 B-1705.13 B-1705.14
B-1705.15
B-1705.16 B-1705.17
B-1705.18
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 6 of 8
Topic Information required Designer documentation
Required/Local conditions
3 Concrete B1901.5
1907.1
Construction documents:
-compressive strength of concrete
-strength / grade of reinforcement
-size / location of reinforcement / anchors
-provision for dimensional changes
-magnitude of prestressing forces
-anchorage length of
reinforcement
-type / location of reinforce splices
-details / location of isolation joints
-Min compress strength –
posttension
-stressing sequences – poststress
tendons
-SDC D, E or F – is slab on grade
designed as a structural
diaphragm
Minimum slab Thickness
Vapor barrier
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 7 of 8
Topic Information required Designer documentation
Required/Local conditions
4 Masonry Allowable Stress design
Masonry Fireplaces
2107.1 / 2106 TMS 402/ACI 530/ASCE 5
B2111.2 Fasteners
Corbelling
Fireplace drawings: Construction documents location size construction Materials thickness characteristics clearances from walls ceilings partitions
5 Steel B2203.1
Structural
Steel joists
SDC B - F
Cold formed steel
Cold formed light frame
2211 structural walls
Steel Truss
2207.2
2207.4
Identification of steel
AISC 360
SJI
seismic design per ASCE 7
AISI S100
AISI S200 / S220
AISI S211 / S100
AISI S214
NYS SED Law
Special loads
Steel joist drawings
6 Wood B2303.1.1
B2303.4.1.1
Certificate of quality of sawn lumber
Truss design drawings NYS SED Law
Page 8 of 8
NYS UNIFORM FIRE PREVENTION AND BUILDING CODE COMMERCIAL DOCUMENTATION CHECKLIST- ENERGY
2020 ECCCNYS
Owner/Project:
Building location: Date: Reviewer:
No Code Section Topic Req Actual
1(a) Energy Code
Climate Zone Compliance Path Commercial
☐ ASHRAE 90.1 - 2016
☐ Prescriptive
☐ Additional Eff Package
☐ Total Performance (Mandatory issues)
☐ ComCheck
E-Tbl C301.1
ASHRAE 90.1 - 2016
E-C402 – C405 &C408
E-C406
E-C407.2
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 9 of 11
1(b) Energy Code Climate Zone Compliance Path Residential
☐ Prescriptive
☐ Simulated Performance
☐ ERI
☐ ResCheck
E-Tbl R301.1
E-R401 – R404
E-R405 R401 – R404 items E-R406
Mandatory items
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 10 of 11
No Code Section Topic Req Actual
2(a) Energy Code Prescriptive
Building Envelope Commercial
Opaque elements R value
U factor
Fenestration
Air Leakage
Building Mechanical System
All mechanical systems
Equip sizing
HVAC perform required
Economizers
Refrig equip efficiency
Service Water Heating
Lighting and Power
Controls
Additional Efficiency Package Options
Commissioning
E- C402
E- Tbl [NY]C402.1.3 E-Tbl [NY]C402.1.4
E- C402.4
E- C402.5
E-C403
E- C403.3.1
E- C403.3.2
E- C403.5
E -C403.10
E- C404
E- C405
E C405.2
E C406 E C406.2
E C406.3
E C406.4
E C406.5
E C406.6
E C406.7
E C406.8
EC406.9
E- C408
Must choose at least one More efficient HVAC
Reduced LPD
Enhanced light controls
On-site renewable energy Dedicated outdoor air
Reduced energy use water heating Enhanced Envelope Reduced air infiltration
This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement
Page 11 of 11
No Code Section Topic Req Actual
2 (b) Energy Code Prescriptive
Building Envelope Residential
Insulation / fenestration
Fenestration
Air leakage
Systems
Controls
Ducts
Piping Insulation
Service Hot Water
Mech Ventilation
Equip Sizing / Efficiency
Lighting and Power
Existing buildings
E-4502
E-Tbl R402.1.2
E- R402.1.2
E – R402.3
R402.4
E-R403
E- R403.1
E- R403.3
E- R403.4
E- R403.5
E- R403.6
E- R403.7
E- R404
E- R501