9f20 ver. 9/28/2020 appendix

41
9F20 Ver. 9/28/2020 Based on the 2020 BCNYS, FCNYS, PCNYS, ECCCNYS APPENDIX Student Exercises and Supplemental Material Commercial Building Plan Review NEW YORK STATE, DEPARTMENT OF STATE Division of Building Standards and Codes One Commerce Plaza 99 Washington Avenue Albany, NY 12231-0001 Phone: (518) 474-4073 Fax: (518) 474-5788 www.dos.ny.gov Table of Contents Building Permit Application Lesson 4 - Rated wall UL design Lesson 4 - Rated floor ceiling assembly UL design Lesson 4 - Rated tube steel UL design Lesson 4 - Elevator exercise Lesson 7 - Fire Alarm component exercise Lesson 6 - Roof shingles. manufacturer’s information Lesson 6: Structural load documentation Lesson 6: Seismic documentation Lesson 6 - Structural Detail - masonry Lesson 8 - Plumbing fixture count exercise Lesson 8: Plumbing supply size exercise Lesson 8: Plumbing drainage size exercise Lesson 8 - Plumbing plan review worksheets Commercial Occupancies Review Guide Commercial Documentation Review Guide Commercial Documentation Review Guide - structural Commercial Documentation Review Guide - energy Page Appendix 2 Appendix 3 Appendix 4 Appendix 5 Appendix 6 Appendix 7 Appendix 11-12 Appendix 13 Appendix 14 Appendix 15 Appendix 16 Appendix 16 Appendix 17-18 Appendix 19 Appendix 20 Appendix 21 Appendix 22

Upload: others

Post on 21-Apr-2022

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 9F20 Ver. 9/28/2020 APPENDIX

9F20 Ver. 9/28/2020 Based on the 2020 BCNYS, FCNYS, PCNYS, ECCCNYS

APPENDIX

Student Exercises and Supplemental Material Commercial Building Plan Review

NEW YORK STATE, DEPARTMENT OF STATE Division of Building Standards and Codes One Commerce Plaza 99 Washington Avenue Albany, NY 12231-0001 Phone: (518) 474-4073 Fax: (518) 474-5788 www.dos.ny.gov

Table of Contents Building Permit Application Lesson 4 - Rated wall UL design Lesson 4 - Rated floor ceiling assembly UL design Lesson 4 - Rated tube steel UL design Lesson 4 - Elevator exercise Lesson 7 - Fire Alarm component exercise Lesson 6 - Roof shingles. manufacturer’s information Lesson 6: Structural load documentation Lesson 6: Seismic documentation Lesson 6 - Structural Detail - masonry Lesson 8 - Plumbing fixture count exercise Lesson 8: Plumbing supply size exercise Lesson 8: Plumbing drainage size exercise Lesson 8 - Plumbing plan review worksheets Commercial Occupancies Review Guide Commercial Documentation Review Guide Commercial Documentation Review Guide - structural Commercial Documentation Review Guide - energy

Page Appendix 2 Appendix 3 Appendix 4 Appendix 5 Appendix 6 Appendix 7 Appendix 11-12 Appendix 13 Appendix 14 Appendix 15 Appendix 16 Appendix 16 Appendix 17-18 Appendix 19 Appendix 20 Appendix 21 Appendix 22

Page 2: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Appendix - 2

Page 3: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Appendix - 3

Page 4: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Appendix - 4

Page 5: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Appendix - 5

Page 6: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Lesson 4 - Elevator Requirements : Chapter 30

Using Chapter 30 and the information on the elevator found on sheet A5 – 1, list those items that should be included in the proposed building. Be sure to site the appropriate section and be prepared to support your conclusions.

1. _______________________________________

2.

_________________________________________

3.

_________________________________________

4.

_________________________________________

5.

_________________________________________

6.

_________________________________________

Appendix - 6

Page 7: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Appendix - 7

Lesson 7 - Fire Protection Equipment Fire Alarm Components

Using Sheets E-4, E-6 and E-7 identify and locate the following. Give sheet number and room name:

1. Fire Alarm control panel: __________________________

2. Fire Alarm sub-control panel: _______________________

3. Duct mount smoke detector: _______________________

4. Tamper switch: __________________________________

5. Wall mount strobe: _______________________________

6. Annunciator panel: _______________________________

Page 8: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Appendix - 8

Page 9: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Structural Documentation

Appendix - 19

Page 10: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Structural Documentation

Appendix - 110

Chapter 16: Design submittals

Topic Information required

Designer documentation

Local conditions

1(a) 1603.1.1 Floor Live

Uniform distributed

Concentrated

Impact

1st floor – 100 psf 2nd floor – 80 psf

3rd floor – 50 psf

Concentrated – all

3,000 psf

Table 1607.1

1607.9

1(b) 1603.1.2

Roof live

None

1(c) 1603.1.3

Roof snow

Ground snow Pg

Flat roof Pf

Pf = .7 PgCeICt

Exosure Ce

Importance I

Thermal Ct Drift surcharge load Pd

Width of snow drift

45 psf

45 psf

Fig 1608.2

ASCE 7 Sec. 7.3

Table 7-2 Table 7-4 Table 7-3

Page 11: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Structural Documentation

Appendix - 12

Chapter 16: Design submittals

Topic Information required Designer documentation

Local conditions

1(d) 1603.1.4

Wind loads Wind speed Vult

Vasd

Risk Category

Importance factor Exposure

Surface roughness

Exposure categories Internal pressure

Components, Cladding

90 mph fastest mile

Category 2

None Manufacturer’s inst’

Fig 1609 Table 1604.5

ASCE 7, Table 6-1

1609.4

1609.4.2

1609.4.3

1609.6.4.4.1

Table 1613.2.5 (1) & (2)

Page 12: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Structural Documentation

Appendix - 13

Chapter 21: Masonry

Page 13: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Structural Documentation

Appendix - 14

Drobysh, John (DOS)
1609.6 deleted in it’
Page 14: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Appendix - 15

Lesson 8 - Plumbing Plan Review Required Plumbing Fixtures

Using the provided floor plans and the Plumbing Code, (Table 403.1 ) determine if there are enough fixtures provided in the building.

Fixture Type Business

Water Closet

Male

Female

Lavatories

Male

Female

Drinking Fountains

Service sink

Richter, Adam (DOS)
Need to change tables 1613.5.6 to 16.2.5
Page 15: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Student Activity Table 604.5 Plumbing Supply Size

Code plans

Water closet ____ ____

Lavatory ____ ____

Drinking fountain ____ ____

Service sink ____ ____

Shower ____ ____

Student Activity

DFU count Table 709.1

Code Total per branch

Water closet ____ ______

Lavatory ____ drain size

Drinking fountain ____ _______

Service sink ____ vent size

Shower ____ _______

Appendix - 16

Page 16: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Lesson 8 - Plumbing Plan Review Drainage Pipe sizing

Example: Drainage stack #1 - Using Sections 709 and 710 of the Plumbing Code and Page P – 4 of the assigned plans, we will determine if the proposed drainage piping is adequate.

Appendix - 17

Page 17: 9F20 Ver. 9/28/2020 APPENDIX

Appendix

Lesson 8 - Plumbing Plan Review Drainage Pipe sizing

Using Sections 709 and 710 of the Plumbing Code and Page P – 4 of the assigned plans, determine if the proposed drainage piping is adequate for the building drain.

Appendix - 18

Page 18: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 1 of 11

NYS UNIFORM FIRE PREVENTION AND BUILDING CODE 2020 BCNYS COMMERCIAL OCCUPANCIES REVIEW CHECKLIST 2020 FCNYS 2020 PCNYS Owner/Project: 2020 MCNYS Building location: 2020 FGCNYS

Date: 2020 ECCCNYS Reviewer:

No Topic Section Required or Allowed Actual

1 Occupancy

Classification Use

B-302

2 Type of Construction

Materials Comb/Non

Fire Resistance

Structural Frame

Bearing walls

Floors

Roof construction

B-602

B-Table 601

3 Building Height & Area

Height (feet)

Height (story)

Allowable area (square feet)

B-503

B-Table 504.3

B-Table 504.4

B-Table 506.2

Cumulative max

Max per story

Page 19: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 2 of 11

No Topic Section Required or Allowed Actual

4 Area Determination

Single occupancy, 1 story

Mixed occupancy, 1 story

Single occupancy, Multiple story

Multiple occupancy, Multiple Story

Mixed Occupancy

Non-separated

Separated uses

B-506.2.1

Equation 5-1

B-506.2.2

Equation 5-1

B-506.2.3

Equation 5-2

B-506.2.4

Equation 5-3

B-508.3 B-508.4

If no frontage increase, use tabular values At Aa = At + (NS × If)

Aa = At + (NS × If)

Aa = [At + (NS × If)] x Sa

Aa = [At + (NS × If)]

5 Area Modifications Area increase formulas Frontage Increase

(P) perimeter of building (F) frontage of building (W) average yard width

Unlimited area

Total Area Allowed

B-506.3.3

Equation 5-5

Equation 5-4

B- 507

If = [F/P - 0.25]W/30 Min 20' Max 30' W = (L1 x W1 + L2 x W2 + L3 …

6 Multiple Use Building

Incidental Use Areas

Mixed Occupancy Accessory Occupancy

Non-separated

Separated Uses Rating required

B-509 B-Table 509

B-508.2 B-508.2.3

B-508.3

B-508.4 B-Table 508.4

Separate/Protect

< 10%, no effect on area

Most restrictive height and building area

Sum of Ratios < 1

Page 20: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 3 of 11

No Topic Section Required or Allowed Actual

7 Location on Property

Fire Separation Distance Wall rating

Exterior Wall Openings

B-Table 602

B-Table 705.8

8 Interior Finishes Wall and Ceiling

Textiles Wall Ceiling

Floor finishes

B-803.1

B-Table 803.13

B- 803.1.2

B- 803.1.3

B-804

9 Interior Environment

Ventilation

Light

Min. Rm. Dimensions

Min. Ceiling Height

B-1202.1

B-1204.1

B-1207.1

B-1207.2

Page 21: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 4 of 11

No Topic Section Required or Allowed Actual

10 Atriums

Sprinkler Protection

Fire Alarm System

Smoke Control

Enclosure

Interior Finish

Travel Distance

Interior exit stairways

B- 404

B- 404.3

B- 404.4

B- 404.5

B- 404.6

B- 404.8

B-404.9

B-404.10

Class B min

Max 50% through Atrium

11 Fire Rated Construction Exterior Walls Projections

Fire Walls Separate Buildings Party Wall

Ratings

Fire Barrier Fire Areas Supporting Construction

Fire Partition

Smoke Barriers

Shaft Enclosure Fire rating Penetrations

Opening Protectives

Concealed Spaces Fire Blocking Draft Stopping

B-705 B-Tbl 705.2

B-706 B-706.1 B-706.1.1 B-Table 706.4

B-707 B-Tbl 707.3.10 B-707.5.1

B-708

B-709

B-713 B-713.4

B-714

B-Table 716.1(2)

B-718

B-718.2 B-718.3 Floors B-718.4 Attics

Min of barrier rating

Min 1 hr

< 4 stories 1 hr min 4 or more stories 2 hr min

Page 22: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 5 of 11

No Topic Section Required or Allowed Actual

12 Fire Protection Equipment Supervisory Service

Sprinkler Systems Where required

Alternate Extinguishing Systems Commercial cooking

Standpipe Systems

Fire Extinguishers

Fire Alarm Systems Where required

Smoke Alarms

Occupant notification

Visible Alarms

Installation/Monitoring

Smoke Control System

Smoke and Heat Removal Fire Department Connections Carbon Monoxide Detection

B-901.6

F/B-903 F/B-903.2

F/B-904 F/B-904.12 F-607

F/B-905

F/B-906

F/B-907 F/B-907.2

F/B-907.2.10

F/B- 907.5

F/B-907.5.2.3

F/B-907.6

F/B-909

F/B-910 F/B-912 F/B-915

Page 23: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 6 of 11

No Topic Section Required or Allowed Actual

13 (a)

Means of Egress

Ceiling Height

Occupant Load

Egress Width (per occupant)

Number of Exits Spaces with one Min exits per story

Egress Illumination Emergency Power Exit Signs - where Emergency Power

B-1003.2

B-Tbl 1004.5

B- 1005.2 B- 1005.3

B- 1006 B- Tbl 1006.2.1 B- Tbl 1006.3.2

B- 1008.2 B-1008.3 B- 1013.1 B- 1013.6.3

13 (b)

Egress Components Doors Size Swing Operation Hardware Panic / Fire Hardware

Stairways Width Headroom Tread /Riser Landings Vertical Rise

Handrails

Luminous Egress marking

B- 1010.1.1 B- 1010.1.2 B- 1010.1.9 B- 1010.1.9.1 B- 1010.1.10

B- 1011 B-1011.2 B-1011.3 B-1011.5 B- 1011.6 B-1011.8

B-1014

B- 1025 High Rise A, B, E, I-1, M, R1

Page 24: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 7 of 11

No Topic Section Required or Allowed Actual

13 (c)

Exit Access

Remoteness

Travel Distance

Spaces w/1 Exit

Story w/1 Exit

Corridors

Fire Rating

Width

Dead ends

B-1007.1.1

B- Tbl 1017.2

B-Tbl 1006.2.1

B – Tbl 1006.3.3(2)

B-1020.1

B- Tbl 1020.1

B- Tbl 1020.2

B-1020.4

14 ACCESSIBILITY

Exempt Spaces

Route Multistory exception

Public Entrances

Parking

Access Aisles

Group I

Group R Dwelling/sleeping units

Special Occupancies Other Facilities

Signage

B-1103.2

B-1104.1 B-1104.4 items #1 - 4

B-1105.1

1106.1.1 B-Tbl 1106.1

B-1106.1.1

B-1107.5

B- 1107.6 1107.6.4 B-Tbl 1107.6.1.1

B-1108 B- 1109

B- 1111.1

60% accessible

8’ minimum access aisle

R-4 accessible and type B

Page 25: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 8 of 11

15 Exterior Wall Water resistive barrier

Vapor retarders

Flashing

Combustible Finishes Min fire separation

Balconies & projections

B-1404.2

B-1404.3

B-1404.4

B-1405.1 B-Tbl 1405.1.1.1.2

B-705.2.3.1

16 Roof Assemblies

Performance Requirements

Gravel/Stone limitation

Installation by Material

Chapter 15

Section 1504

B-1504.8

B-Tab 1504.8

B-1506

17 Structural Documentation – see Commercial Structural Documentation Checklist

18 Special Inspections - see Commercial Structural Documentation Checklist

19 Energy – see Commercial Energy checklist

Page 26: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 9 of 11

20 Masonry Mortar

Method

Seismic Design Allowable Stress

Strength of Masonry

Empirical Design

Glass Masonry Masonry Fireplaces

Footing / Foundations

Seismic reinforcement

Seismic anchorage

Firebox walls

Firebox dimensions

Hearth and Extension

Fireplace clearance

Fireplace fireblocking

Exterior air

Masonry Heaters

Masonry Chimneys

2103.2

2106 and

2107 and

2108 and

2109 and

2109.1.1

2110 and 2111

2113.2

2111.3

2111.5

2111.6

2111.7

2111.10

2111.12

2111.13

2111.14

2112

2113 2114

Compliance

Ch 7, TMS 402/ACI 530/ASCE 5 2106; Ch 8,TMS 402/ACI 530/ASCE 5 2106; TMS 402/ACI 530/ASCE 5 Appdx A, TMS 402/ACI 530/ASCE 5 Never Risk Category IV structures Never where Vasd >110mph

Ch 13, TMS 402/ACI 530/ASCE 5

Minimum 12” thick, 6” wider than fireplace

SDC C or D SDC E or F

At every floor, ceiling roof line

Min 20” depth; throat min 8” above opening Min 2” combustibles; back 4”

Minimum thickness

required

Page 27: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 10 of 11

21 Plumbing Code General Requirements Pipe freezing Structural safety Pipe support Tests / inspections

Fixture Count

Water Supply Service Pipe Size Fixture Pipe Size

Pipe Material

Valves required

Sanitary Drainage/Vent DWV Pipe Material Cleanouts Drain Fixture Units Building Drain Sizes

Stack and Branch size Waste vents Size & length

Air Admittance Valves

Storm Drainage

P- 305.4 P-307 P-Tbl 308.5

P-312

P-Tbl 403.1

P-603.1 P-Tbl 604.5 P-Tbl 605.4

P-606.1, 606.2

P-702 P-708 P-Tbl 709. P-Tbl 710.1(1)

P-Tbl 710.1(2)

P-Tbl 906.1

P-918

P-1106

Page 28: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 11 of 11

22 Mechanical Code Ventilation required Mechanical ventilation

Propane Ventilation

Dryer Exhaust

Kitchen Exhaust Kitchen Hoods Kitchen Make-Up Air Cooking Fire Suppression

Plenums Fire & Smoke Dampers

Combustion Air Chimney / Vents

M-401.2 M-403.2 M- Tbl 403.3.1.1 M-502.9.10 M-504

M-506 M-507 M-508 M-509

M-602 M-607.5

M-701 M-801

R2, R3, R4 req mech

23 Fuel Gas Code

Appliance Location

Combustion Air

Clearance to combustibles

Access

Pipe Material

Shut Off Valves

Chimney Termination

Gas Vent Termination

Vent Termination Location

Clothes Dryer Exhaust

Unvented Room Heater

Cooking Appliances

FG-303

FG-304.1

FG-305.8

FG-306

FG-403

FG-409

FG-503.5.4

FG-Fig. 503.6.5

FG-503.8

FG-614

FG-621 FG-623

Page 29: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

NYS UNIFORM FIRE PREVENTION AND BUILDING CODE 2020 BCNYS COMMERCIAL OCCUPANCIES REVIEW CHECKLIST 2020 FCNYS 2020 PCNYS Owner/Project: 2020 MCNYS Building location: 2020 FGCNYS

Date: 2020 ECCCNYS

Reviewer:

No Code / item Section Topic Req Actual

1 Building Code B302 Occupancy

Use

1(a) Special Detailed Use B402.3 Covered/Open Malls

Lease plan

1(a) Occupant load increase B1004.5.1 Floor diagram required

1(a) Rooftop assemblies B1504.1.1

B1505.6

B1505.8

B1506

Wind resistance

Asphalt shingles labeled for compliance w/ ASTM7158 or 3161

Fire resistance

Wood shakes bundles labeled with:

-manufacturer

-classification of material

-treating company

Building integrated PV

-listed / labeled fire classification

Materials

-packages bear mfg markings / test info

1(a) Structural Use Commercial structural guide

1(a) Concrete Use Commercial structural guide

Page 1 of 2

Page 30: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Appendix - 20

No Code / item Section Topic Req Actual

1(a) Steel Use Commercial structural guide

1(a) Wood Use Commercial structural guide

1(a) Masonry Use Commercial structural guide

1(a) Temporary structures B3103.2 Construction documents: -site plan with location, means of egress and occupant load

1(a) Safeguards B3303.1 Construction documents and schedule

2 Plumbing Code P-303.4

P-312.1

P-316.1.2

P-715

P-716.7

3rd party certification

Required Tests

Alternate system submittal

Vacuum drainage system

Pipe bursting post-inspection

3 Mechanical Code

M-301.5

M-301.7

M-312.1

M-403.2

M-407

M-504.8.4.2

M-508.1.2

3rd Party Certification

Listed & Labeled

Heating Load Calculations

Outdoor Air Required

I-2 / Ambulatory care vent

Clothes dryer exhaust – Manuf

Commercial hood air balance

4 Energy code Use Commercial energy code guide

Page 2 of 2

Page 31: 9F20 Ver. 9/28/2020 APPENDIX

ubmitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate

Page 1 of 8

NYS UNIFORM FIRE PREVENTION AND BUILDING CODE COMMERCIAL DOCUMENTATION REVIEW CHECKLIST- Structural

Owner/Project: Building location: Date: Reviewer: 2020 BCNYS

Topic Information required Designer documentation

Required/Local conditions

1(a) 1603.1.1 Floor Live

Uniform distributed

Concentrated

Impact

Table 1607.1

1607.8

1(b) 1603.1.2 Roof live

1607.13

1(c) 1603.1.3 Roof snow

Ground snow Pg

Flat roof Pf (Pf = .7 PfCeICt) Exposure Ce Importance I Thermal Ct

Drift surcharge load. Pd

Width of snow drift where the sum of Pd & Pf exceeds 20 psf

Fig 1608.2

ASCE 7 Sec. 7.3

Table 7-2 Table 7-4 Table 7-3

1(d) 1603.1.4 Wind loads

Wind speed Vult

Vasd

Risk Category Importance factor I

Exposure Surface roughness Exposure categories Internal pressure Components, Cladding

Fig 1609.3(1) through 1609.3(4) Tab 1604.5 ASCE 7, Tab 6-1

1609.4 1609.4.2 1609.4.3

B- 1609.6.4.4.1

Page 32: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 2 of 8

Topic Information required Designer documentation

Required/Local conditions

1(e)

Information Required___

1603.1.5 Earthquake design

Ss and S1

Risk Category

Soils/Site Class

Sds and Sd1

Seismic Design Category

Force resisting system

Design base shear

Response coefficient, CS

Response factor(s), R Analysis procedure

Table 1604.5: _____________

Zip __________ Ss ______ S1 ______ SDC per Tables 1613.2.5 (1)&(2) Completed by CEO

Site Sds

Sd1

SDC

I&II III IV

A

B

C

D

E

1(f) Geotechnical

1603.1.6

Design load bearing value of soils

Page 33: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 3 of 8

Topic Information required Designer documentation

Required/Local conditions

1(g) 1603.1.7

Flood load

1612.3

Flood Hazard Y/N

Elevation lowest floor

Elevation dry

floodproof

High velocity wave

Y/N

Elevation lowest horizontal member

FIRM/FBFM map date

1(h) 1603.1.8

Special Loads

1(i) Special Loads

1603.1.8.1

Rooftop Photovoltaic panel system – dead load

Page 34: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 4 of 8

Topic Information required Designer documentation

Required/Local conditions

2(a) Special inspections B1703.1

B1703.1.1

B1703.1.2

B1703.1.3

B1703.2

B1703.4

B1703.6

B1703.6.2

B1704.2.1

B1704.3

B1704.5

B1704.6

B1705

Approved Agency: - No conflict of interest - Adequate equipment - Experienced personnel Written approval submitted of required tests / reports Performance of product, material, assembly meets code requirements Evaluation – prefab assembly Necessary test / special inspection records Special inspector qualifications Statement of Special Inspections Submittals to the code official Structural Observations

-Seismic observations -Wind requirements Vasd > 110 mph Required Special Inspections Steel Concrete Masonry Wood Soils Driven deep foundations Cast in place deep foundations Helical Pile foundations Fabricated items Wind resistance Seismic resistance Sprayed fire resistant materials Mastic / Intumescent fire retardant coatings Fire resistant penetrations / joints

Page 35: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 5 of 8

Topic Information required Designer documentation

Required/Local conditions

2(b) Special Inspections

Approved Agency Written approval Special Inspector Qualifications Spec Insp Statement Spec Insp Statement Wind Seismic Structural Observation Seismic Wind Special Inspection Topic Steel Constr Concrete Constr Masonry Constr Wood Constr Soils Driven Deep Found Cast in Place Found Helical Pile Found Fabricated items Spec Insp for Wind Spec insp for Seismic Testing / Seismic resist Spray Fire Resist Mastic / Intumescent coatings

Ext Insulation / Finish Fire Resist Penetrations/Joints Smoke Control Test

Appliance, equip, system

Applicant

Design professional Design professional

B-1703.1 B-1703.2 B-1704.2.1

B-1704.2.3 B-1704.3 B-1704.3.2 B-1704.3.3

B-1704.6.1 B-1704.6.2

B-1705.2

B-1705.3 B-1705.4 B-1705.5 B-1705.6 B-1705.7 B-1705.8

B-1705.9

B-1705.10 B-1705.11 B-1705.12 B-1705.13 B-1705.14

B-1705.15

B-1705.16 B-1705.17

B-1705.18

Page 36: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 6 of 8

Topic Information required Designer documentation

Required/Local conditions

3 Concrete B1901.5

1907.1

Construction documents:

-compressive strength of concrete

-strength / grade of reinforcement

-size / location of reinforcement / anchors

-provision for dimensional changes

-magnitude of prestressing forces

-anchorage length of

reinforcement

-type / location of reinforce splices

-details / location of isolation joints

-Min compress strength –

posttension

-stressing sequences – poststress

tendons

-SDC D, E or F – is slab on grade

designed as a structural

diaphragm

Minimum slab Thickness

Vapor barrier

Page 37: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 7 of 8

Topic Information required Designer documentation

Required/Local conditions

4 Masonry Allowable Stress design

Masonry Fireplaces

2107.1 / 2106 TMS 402/ACI 530/ASCE 5

B2111.2 Fasteners

Corbelling

Fireplace drawings: Construction documents location size construction Materials thickness characteristics clearances from walls ceilings partitions

5 Steel B2203.1

Structural

Steel joists

SDC B - F

Cold formed steel

Cold formed light frame

2211 structural walls

Steel Truss

2207.2

2207.4

Identification of steel

AISC 360

SJI

seismic design per ASCE 7

AISI S100

AISI S200 / S220

AISI S211 / S100

AISI S214

NYS SED Law

Special loads

Steel joist drawings

6 Wood B2303.1.1

B2303.4.1.1

Certificate of quality of sawn lumber

Truss design drawings NYS SED Law

Page 38: 9F20 Ver. 9/28/2020 APPENDIX

Page 8 of 8

NYS UNIFORM FIRE PREVENTION AND BUILDING CODE COMMERCIAL DOCUMENTATION CHECKLIST- ENERGY

2020 ECCCNYS

Owner/Project:

Building location: Date: Reviewer:

No Code Section Topic Req Actual

1(a) Energy Code

Climate Zone Compliance Path Commercial

☐ ASHRAE 90.1 - 2016

☐ Prescriptive

☐ Additional Eff Package

☐ Total Performance (Mandatory issues)

☐ ComCheck

E-Tbl C301.1

ASHRAE 90.1 - 2016

E-C402 – C405 &C408

E-C406

E-C407.2

Page 39: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 9 of 11

1(b) Energy Code Climate Zone Compliance Path Residential

☐ Prescriptive

☐ Simulated Performance

☐ ERI

☐ ResCheck

E-Tbl R301.1

E-R401 – R404

E-R405 R401 – R404 items E-R406

Mandatory items

Page 40: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 10 of 11

No Code Section Topic Req Actual

2(a) Energy Code Prescriptive

Building Envelope Commercial

Opaque elements R value

U factor

Fenestration

Air Leakage

Building Mechanical System

All mechanical systems

Equip sizing

HVAC perform required

Economizers

Refrig equip efficiency

Service Water Heating

Lighting and Power

Controls

Additional Efficiency Package Options

Commissioning

E- C402

E- Tbl [NY]C402.1.3 E-Tbl [NY]C402.1.4

E- C402.4

E- C402.5

E-C403

E- C403.3.1

E- C403.3.2

E- C403.5

E -C403.10

E- C404

E- C405

E C405.2

E C406 E C406.2

E C406.3

E C406.4

E C406.5

E C406.6

E C406.7

E C406.8

EC406.9

E- C408

Must choose at least one More efficient HVAC

Reduced LPD

Enhanced light controls

On-site renewable energy Dedicated outdoor air

Reduced energy use water heating Enhanced Envelope Reduced air infiltration

Page 41: 9F20 Ver. 9/28/2020 APPENDIX

This document is not intended to be all inclusive but rather as a guide for documentation required to be submitted to the local code official as related to the commercial building construction process. Those item in Italics are referenced from the appropriate supplement

Page 11 of 11

No Code Section Topic Req Actual

2 (b) Energy Code Prescriptive

Building Envelope Residential

Insulation / fenestration

Fenestration

Air leakage

Systems

Controls

Ducts

Piping Insulation

Service Hot Water

Mech Ventilation

Equip Sizing / Efficiency

Lighting and Power

Existing buildings

E-4502

E-Tbl R402.1.2

E- R402.1.2

E – R402.3

R402.4

E-R403

E- R403.1

E- R403.3

E- R403.4

E- R403.5

E- R403.6

E- R403.7

E- R404

E- R501