96RACK5-ST-R1-AR5
Function Test Report
Initiated by Jeff Wang Approved by River Lin
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 2 of 16
Revision History:
Date Revision Description Creator
2014/10/28 V1.0 The First version released. Jeff Wang
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 3 of 16
Test Results Definition:
Criteria Definition
PASS Test result pass and function work perfectly.
Fail Test fail or can not meet the spec requirement.
Limitation There are no plans to fix this function.
N/A Spec not support or driver not ready.
Check Next Version HW modified circuit and solution verfied, and check the function result has
pass. Need to check next version.
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 4 of 16
Test Results Summary:
Num. Test Item Result Remark
Chapter 1 Function Test
1.01 LCD Display Information Pass
Chapter 2 Software Compatibility Test
2.01 Microsoft Operation System Pass
2.02 Microsoft Server Operation System Pass
Chapter 3 Hardware Compatibility Test
3.01 SATA2 Devices Compatibility Test Pass
3.02 SATA3 Devices Compatibility Test Pass
Chapter 4 System Reliability Test
4.01 PassMark BurnIn Test–Disk Test Pass
Chapter 5 System Performance Test
5.01 SATA3 Performance Test Pass
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 5 of 16
Table of Contents
Revision History: ........................................................................................................................................................ 2
Test Results Definition: ............................................................................................................................................. 3
Test Results Summary: .............................................................................................................................................. 4
Table of Contents .......................................................................................................................................................... 5
Product Specification: ............................................................................................................................................... 6
System Configuration: ................................................................................................................................................. 9
Test Programs: ............................................................................................................................................................ 10
Chapter 1:Function Test ......................................................................................................................................... 11
1.01 LCD Display Information .......................................................................................................................... 11
1.01.01 LCD Display information check ........................................................................................................................... 11
Chapter 2:Software Compatibility Test ................................................................................................................. 12
2.01 Microsoft Operation System ...................................................................................................................... 12
2.01.01 O.S & Driver Installation Test .............................................................................................................................. 12
2.02 Microsoft Server Operation System .......................................................................................................... 13
2.02.01 Server O.S & Driver Installation Test ................................................................................................................... 13
Chapter 3:Hardware Compatibility Test .............................................................................................................. 14
3.01 SATA2 Devices Compatibility Test ........................................................................................................... 14
3.02 SATA3 Devices Compatibility Test ........................................................................................................... 14
Chapter 4:System Reliability Test .......................................................................................................................... 15
4.01 PassMark BurnIn Test-Disk Test .............................................................................................................. 15
Chapter 5:System Performance Test ..................................................................................................................... 16
5.01 SATA3 Performance Test .......................................................................................................................... 16
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 6 of 16
Product Specification:
ARAID 5000 Specification
Advantech P/N 96RACK5-ST-R1-AR5
Host Interface SATA III (6.0Gbps), compatible with SATA II (3.0Gbps)
Hard Driver Interface 3.5 inch SATA III (6Gbps) x2
RAID Level RAID 1 or RAID 0 (User can set manually)
Front Panel LCD Displays status of system, hard drive, cooling fan and temperature information
LED Indicator Shows hard disks READ or WRITE status
Hard Drive Fail Alert LCD, LED, Buzzer, Email and SNMP Trap Notifications
Single/Dual Switch Mirror-on-Demand function, rebuild disk manually, which can protect
Standby hard disk accidental data deletion and anti-virus function
Cooling Fan 6cm powerful and silent cooling fan (Made in Japan)
No Driver Yes
HDD Hot-Swap Yes
OS Support Windows, Linux, Mac, Solaris, SCO Unix, NetWare, DOS etc.
Dimension Internal Model: standard 5.25” drive bay x 2.146 mm(W) x 86 mm(H) x 195 mm(D)
External Model: 183 mm(W) x 156 mm(H) x 24 mm(D)
Weight (without HDD) Internal Model: approx. 0.7kg
External Model: approx. 2.68kg
Power Consumption Internal model (without HDD): approx. 5.14W ~ 7.32W (depend on models).
External model: 63W
Power Supply
Internal Model: Dual Power (Traditional Large 4-pin Power Socket x 1 & SATA
Power Socket x1)
External Model: AC 100V ~ 240V
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 7 of 16
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 8 of 16
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 9 of 16
System Configuration:
Item. Description.
M/B Name AIMB-584
PCB Version. A101-2
BIOS Version. AIMB W584X036
CPU Model/Info Intel Xeon E3-1275 v3 (3.5GHz)
Memory Type/Info/Size Transcend 1G DDR3-1333 x2
Chipset SB: Intel C226
Graphic Controller Intel HD Graphics P4600/P4700
Power Supply Model ADVANTECH FSP250-70PFU
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 10 of 16
Test Programs:
Test Program Version
HD Tune Pro V5.50
PassMark Burn-In Test Pro V8.0 build 1012
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 11 of 16
Chapter 1:Function Test
1.01 LCD Display Information
1.01.01 LCD Display information check
1.01.01.01 Test Purpose:
The purpose of this test is to validate and ensure the functional of the LCD Display.
1.01.01.02 Test Data:
Test Item Description Result Remark
RAID 0 single HDD Single HDD with RAID 0 level Pass
RAID 0 dual HDD Dual HDD with RAID 0 level Pass
RAID 1 single HDD Single HDD with RAID 1 level Pass
RAID 1 dual HDD Dual HDD with RAID 1 level Pass
RAID 1 rebuild HDD Start disk rebuild on RAID 1 level Pass
FAN Failure Cooling FAN failure Pass
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 12 of 16
Chapter 2:Software Compatibility Test
2.01 Microsoft Operation System
2.01.01 O.S & Driver Installation Test
2.01.01.01 Test Purpose:
The purpose of this test is to ensure the OS compatibility of the RAID Level.
2.01.01.02 Test Data:
RAID Level:RAID-0 & RAD-1
Test Item Description Result Remark
Win7 Ultimate SP1 x86
OS Installation – English. Pass
Seagate ST4000VX000
WD WD10PURX-64D85Y0
WD WD40PURX-64GVNY0
WD WD2003FYYS-02W0B1
Driver Installation. Pass
Device Management Check. Pass
Win7 Ultimate SP1 x64
OS Installation – English. Pass
Driver Installation. Pass
Device Management Check. Pass
Win8.1 Pro X86 with
Update
OS Installation – English. Pass
Driver Installation. Pass
Device Management Check. Pass
Win8.1 Pro X64 with
Update
OS Installation – English. Pass
Driver Installation. Pass
Device Management Check. Pass
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 13 of 16
2.02 Microsoft Server Operation System
2.02.01 Server O.S & Driver Installation Test
2.03.02.01 Test Purpose:
The purpose of this test is to ensure the Server OS compatibility of the RAID Level.
2.03.02.02 Test Data:
RAID Level:RAID-0 & RAID-1
Test Item Description Result Remark
Win Server_2008 R2
SP1 Enterprise_x86
OS Installation – English. Pass
Seagate ST4000VX000
WD WD10PURX-64D85Y0
WD WD40PURX-64GVNY0
WD WD2003FYYS-02W0B1
Driver Installation. Pass
Device Management Check. Pass
Win Server_2008 R2
SP1 Enterprise_x64
OS Installation – English. Pass
Driver Installation. Pass
Device Management Check. Pass
Win Server 2012
Standard_x64
OS Installation – English. Pass
Driver Installation. Pass
Device Management Check. Pass
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 14 of 16
Chapter 3:Hardware Compatibility Test
3.01 SATA2 Devices Compatibility Test
3.01.01.01 Test Purpose:
The purpose of this test is to validate and ensure the SATA2 compatibility of the araid 5000-GP.
3.01.01.02 Test Data:
SATA2 Devices - 3.5"
Test
Item Description
Result Remark Brand
Name Model Type
Capacity/
Speed Mode Advantech PN
WD WD2003FYYS 3.5" SATA HDD 2000GB SATA II 96HD2000G-ST-WD7K Pass
3.02 SATA3 Devices Compatibility Test
3.02.01.01 Test Purpose:
The purpose of this test is to validate and ensure the SATA3 compatibility of the araid 5000-GP.
3.02.01.02 Test Data:
SATA3 Devices - 3.5"
Test Item Description
Result Remark Brand
Name Model Type
Capacity/
Speed Mode Advantech PN
WD WD10PURX 3.5" SATA HDD 1000GB SATAIII 96HD1TB-ST-WD5KA Pass
WD WD40PURX 3.5" SATA HDD 4000GB SATAIII Pass
Seagate ST4000VX000 3.5" SATA HDD 4000GB SATAIII Pass
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 15 of 16
Chapter 4:System Reliability Test
4.01 PassMark BurnIn Test-Disk Test
4.01.01.01 Test Purpose:
The purpose of this test is to ensure the araid 5000-GP reliability.
4.01.01.02 Test Data:
RAID Level:RAID-0
Test Item Description OS Result Remark
Disk(s) – 12Hrs.
Default preference:
Test mode: Default (Cyclic)
Slow drive threshold: NA
File size: 15 (% of disk space)
Win7 Ultimate SP1 x64 Pass
Win8.1 Pro X64 with Update Pass
Win Server_2008 R2 SP1
Enterprise_x64 Pass
Win Server 2012
Standard_x64 Pass
RAID Level:RAID-1
Test Item Description OS Result Remark
Disk(s) – 12Hrs.
Default preference:
Test mode: Default (Cyclic)
Slow drive threshold: NA
File size: 15 (% of disk space)
Win7 Ultimate SP1 x86 Pass
Win8.1 Pro X86 with Update Pass
Win8.1 Pro X64 with Update Pass
Win Server_2008 R2 SP1
Enterprise_x86 Pass
Win Server 2012
Standard_x64 Pass
Drawings and specifications herein are property of Advantech and shall not be reproduced or copied or used without prior written permission.
Page 16 of 16
Chapter 5:System Performance Test
5.01 SATA3 Performance Test
5.01.01.01 Test Purpose:
The purpose of this test is to ensure the SATA3 performance of the araid 5000-GP.
5.01.01.02 Test Data:
SATA3 Performance (OS: Win7 Ultimate SP1 X86_X64)
Test
Item HD Tune Pro 5.5 WD2003FYYS WD40PURX ST4000VX000 WD10PURX Remark
RAID-0
Burst Speed / (MB/s) 250.5 275 315.7 276.7
Transfer Rate - Min.
(MB/s) 1.4 127.9 150.5 42.5
Transfer Rate - Max.
(MB/s) 273.3 289.6 310.1 297.4
Transfer Rate - Average.
(MB/s) 204.5 216.3 259.2 223.4
Access Time (ms) 17.2 21 16.1 20.1
CPU Utilization (%) 2.7 2.8 3.6 2.9
RAID-1
Burst Speed / (MB/s) 176.6 255.2 234.1 237.4
Transfer Rate - Min.
(MB/s) 60.3 56.7 55.3 41
Transfer Rate - Max.
(MB/s) 137 148.6 172.8 150
Transfer Rate - Average.
(MB/s) 109.1 109.8 132.9 117.7
Access Time (ms) 12.4 21.5 15.4 21.4
CPU Utilization (%) 3 3.6 3.9 2.3