Alcatel-Lucent GSM

9125 Transcoder Alarm Dictionary

BSC & TC Document

Reference Guide

Release B10

3BK 21265 AAAA PCZZA Ed.02

Status RELEASED

Short title TC Alarm Dico

All rights reserved. Passing on and copying of this document, useand communication of its contents not permitted without writtenauthorization from Alcatel-Lucent.

BLANK PAGE BREAK

2 / 110 3BK 21265 AAAA PCZZA Ed.02

Contents

Contents

Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.2 A1353-RA AS Alarm Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81.3 LMT Alarm Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.4 Alarm Information Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

2 Class 66: TSC_TRUNK Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172.1 [66,22] LOOP-TO-EQUIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182.2 [66,50] TWO-MB-MISSING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192.3 [66,66] AIS-2-MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212.4 [66,81] FRAME-ALIGNMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232.5 [66,86] CRC-MFRAME-ALGN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252.6 [66,99] BER-10E-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272.7 [66,100] BER-10E-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292.8 [66,102] BER-10E-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312.9 [66,176] FAR-END-ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332.10 [66,210] TRANS-FLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352.11 [66,211] LOSS-OF-CLK-2M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372.12 [66,231] E1-AIS-2-MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 392.13 [66,232] E1-FRAME-ALIGNMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412.14 [66,233] E1-CRC-MFRAME-ALGN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432.15 [66,234] E1-BER-10E-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 452.16 [66,235] E1-BER-10E-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 472.17 [66,236] E1-RAI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 492.18 [66,237] E1-BER-10E-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

3 Class 102: TC_TRANS Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 533.1 [102,210] SFP_UNEQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 543.2 [102,211] RS_LOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 553.3 [102,212] RS_LOF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 563.4 [102,214] MS_AIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 573.5 [102,215] MS_RDI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 583.6 [102,216] MS_SF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 593.7 [102,217] MS_SD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 603.8 [102,221] AU_LOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 613.9 [102,222] AU_AIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 623.10 [102,223] SFP_WRONGTYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 633.11 [102,231] HP_UNEQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643.12 [102,232] HP_PLM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 653.13 [102,233] HP_RDI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 663.14 [102,234] HP_LOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

4 Class 103: TC_IF Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

4.1 [103,0] RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 704.2 [103,1] TAKEOVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 714.3 [103,2] TAKEOVER_REFUSED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 724.4 [103,4] ACCESS_FAIL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 734.5 [103,6] UNPLUGGED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 744.6 [103,7] HOST_FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 754.7 [103,10] HW_FAULT_FATAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 764.8 [103,11] TEMPERATURE_FATAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 774.9 [103,12] TEMPERATURE_MAJOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 784.10 [103,13] TEMPERATURE_MINOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 804.11 [103,14] VOLTAGE_FATAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

3BK 21265 AAAA PCZZA Ed.02 3 / 110

Contents

4.12 [103,15] VOLTAGE_MAJOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 834.13 [103,16] VOLTAGE_MINOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 854.14 [103,17] RLC_OV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 874.15 [103,19] OBC_OVERLOADING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 894.16 [103,20] PROCESS_TERMINATION_FATAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 914.17 [103,23] HSI_FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 924.18 [103,24] FAN_FAILURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 944.19 [103,28] INTERNAL_CLOCK_INCONSYSTENCY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 954.20 [103,29] POWER_SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96

5 Class 105: TRANSCODER Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 975.1 [105,000] POWER-SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 985.2 [105,128] EQUIPMENT-FAULT(2nd or more DSP faulty - loop test) . . . . . . . . . . . . . . . . . . . . . 995.3 [105,130] MEMORY-FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1015.4 [105,136] FIRST-DSP-FAIL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1035.5 [105,148] RESET (1st DSP faulty, 2nd or more DSP faulty- HW watchdog- HW failure- more

than 3 autoresets in 24 hours.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1055.6 [105,210] TRANS-FLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1065.7 [105,211] LOSS-OF-CLK-2M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1085.8 [105,216] RESTART (DSP restart OTP restart) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110

4 / 110 3BK 21265 AAAA PCZZA Ed.02

Preface

Preface

Purpose The purpose of the alarm dictionary is to provide the operator with a structuredmethod for handling alarm messages generated and reported by the 9125Transcoder.

This document contains a list of all 9125 Transcoder reported, and the actionsrequired to nullify them.

Alarms are displayed at the OMC-R terminal and at the LMT to inform theoperator of system faults.

Note: When a fault occurs, a number of alarms can be generated simultaneously.These alarms must be analyzed as a group to determine the precise fault.

What’s New In Edition 02The following alarms have been added:

[66,22] LOOP-TO-EQUIP (Section 2.1)

[66,50] TWO-MB-MISSING (Section 2.2)

[66,66] AIS-2-MB (Section 2.3)

[66,237] E1-BER-10E-6 (Section 2.18)For alarm class 66, alarms from 231 to 237 and for alarm class 105 theperceived security field was completed.

In Edition 01First official release of document.

3BK 21265 AAAA PCZZA Ed.02 5 / 110

Preface

Audience This document is aimed at telecommunications operators responsible forperforming O&M fault handling and troubleshooting tasks.

Assumed Knowledge The operator must be familiar with the following:

Alcatel-Lucent O&M concepts for the BSS

MO scenario

Fault management

Use of OMC-R and BSC terminals

SBL hierarchies of the BTS, BSC and TC

Telecommunications techniques including line transmission and switching.

6 / 110 3BK 21265 AAAA PCZZA Ed.02

1 Introduction

1 Introduction

This section describes the structure of alarm messages.

3BK 21265 AAAA PCZZA Ed.02 7 / 110

1 Introduction

1.1 OverviewThis alarm dictionary provides additional information that is not displayed in thealarm messages sent to the OMC-R, BSC or TC terminals.

The dictionary contains alarm definitions for each alarm type produced bythe BSS.

Each definition describes the:

Alarm definition

Alarm description

Impact on System

Methods for further fault isolation

Corrective actions.

1.2 A1353-RA AS Alarm InformationIn the A1353-RA OMC-R, Alarm Surveillance provides an efficient means tocontrol, supervise and manage equipment problems in the BSS.

Alarms or Alarm notifications consist of messages sent by network resourcesthat have detected problems or failures in the network. These alarms aredisplayed in lists while alarm counters keep track of statistics. By clicking on analarm in the list, the operator gets detailed information. AS displays informationas described below.

1.2.1 Object Identification

The Object Identification identifies the resource that raised the alarm.

Object identification gives information about:

The resource type (Object Class)

The resource name (Friendly Name). For a board, the Friendly Name alsoshows the board’s location by rack, shelf and slot.

8 / 110 3BK 21265 AAAA PCZZA Ed.02

1 Introduction

1.2.2 Alarm Type

The Alarm Type identifies the type of problem the alarm refers to.

This information is sub-divided into:

eventType. Table 1 describes the five eventTypes.

probableCause

perceivedSeverity: gives the severity level of the alarm. Table 2 describesthe severity levels.

eventType Indicates...

Communication a problem with a procedure or process used to convey information fromone point to another in the network.

Quality of Service degradation in the quality of service in the network.

Processing Error a software or processing fault.

Equipment an equipment fault.

Environmental a problem in the enclosure containing the equipment.

Table 1: Event Types

Severity Level Indicates...

Critical a serious fault condition which requires immediate correction. Example: amanaged object goes out of service.

Major a fault condition which requires urgent corrective action. Example: severedegradation in the operation of a managed object.

Minor a fault condition which does not affect service but corrective action shouldbe taken to avoid a more serious fault.

Warning detection of a potential fault condition. Action should be taken to diagnoseand correct the problem to avoid a more serious fault condition.

Indeterminate the severity level cannot be defined by the resource which raised the alarm.

Cleared the alarm was cleared by the resource which raised the alarm.

Table 2: Alarm Severity Levels

In addition to the Object Identification and Alarm Type information, all alarmsalways give the date and time of the alarm. An alarm may also contain optionalinformation, such as the notification id. Refer to the AS on-line help for moredetailed information on AS.

3BK 21265 AAAA PCZZA Ed.02 9 / 110

1 Introduction

1.3 LMT Alarm MessagesThe format of Alarms displayed at a LMT differs from that in the OMC -R.

Depending on the type of alarm and where it is viewed, an alarm messagecontains all or most of the parameters listed in this section.

1.3.1 Message Identity

The identity number given to the alarm message stored in the OMC-R database.

1.3.2 Event Time

The time the message was issued at its source or received at the OMC-R.

1.3.3 Location

The origin of the alarm, consisting of:

Network element - the BSS identity

Unit type:

bts

bsc

tcsm

bie

tsc

bss.

Unit number:

0 or 1 for a tcsm

0 to 40 for a bie

1 for a bsc, tsc or bss

1 to 40 for a bts.

SBL type

SBL number and subnumber, if appropriate. For example, RTS (3, 4) is RTSnumber 4 of FU3 (the parent SBL).

10 / 110 3BK 21265 AAAA PCZZA Ed.02

1 Introduction

1.3.4 Classification

The characteristics of the alarm, consisting of:

Alarm Class name and number - as shown in the Contents list of the

Alarm Dictionary

Alarm Type name and number - as shown in the Contents list of the Alarm

Dictionary

Alarm Number - dependent on the Alarm Class and Type. See theappropriate dictionary entry for the valid alarm numbers for a particular alarm

Alarm Condition - has one of the following values:

begin - alarm on. For fatal failures, the affected SBL changes state to

FLT or FOS. For non-fatal failures, the affected SBL changes state to FIT

end - alarm off. Indicates the successful recovery of the system. The

affected SBL may not change state if other alarms related to theSBL are on

event - occurrence of anomaly. No action is required unless it occurs

frequently. Event alarms are of short duration and the affected SBLdoes not change state. The system retry/recovery mechanism has

cleared the fault.

If a fatal alarm occurs and the affected SBL changes state to FOS, the systemisolates the faulty equipment if it cannot be initialized. After a repair action, theoperator normally initializes the equipment.

If a fatal alarm occurs and the affected SBL changes state to FLT, the systemresets the faulty equipment. When the alarm ceases, the system automaticallyinitializes the equipment.

If a non-fatal alarm or event occurs, the affected SBL’s are put into the FIT state.In the worst situation, the equipment operates in a degraded mode.

3BK 21265 AAAA PCZZA Ed.02 11 / 110

1 Introduction

1.3.5 SBL States

An SBL has one of the following (current) states:

IT

FIT

Faulty

EF

FOS

OPR

SOS

WTC

UT

NEQ

MSD

MSD AUTO.

Refer to the Operations & Maintenance Principles for a description of the states.

1.3.6 RIT List

The information for the suspected RIT(s) is displayed if the system is able todetermine the location of the fault.

The information consists of:

Unit type - bts, bsc, tscm, bie, tsc or bss

Unit number -

0 or 1 for a tcsm

0 to 40 for a bie

1 for a bsc, tsc or bss

1 to 40 for a bts.

Physical location - the position of the RIT board within the cabinet. For

example, [A, 4, 21] indicates the board in slot 21 of rack 4 of cabinet A.For BSC and BTS equipment, the cabinets are identified as 1, 2, 3, etc.

instead of A, B, C, etc.

RIT type - the name of the RIT board.

If more than one RIT is shown in the list, the RIT most likely to be causing thefault is indicated. Replace this RIT first and initialize it. If the fault persists,replace another RIT from the list and initialize it.

12 / 110 3BK 21265 AAAA PCZZA Ed.02

1 Introduction

1.4 Alarm Information FormatEach alarm definition and description in the dictionary is structured as follows:

1.4.1 Alarm Definition

MO format LMT format

Banner Banner

specificProblems Alarm Class & [number] - Alarm Type & [number]

eventType -

probableCause -

perceived Severity Category

SBL SBL

Table 3: Alarm Definition:

1.4.2 Alarm Description

The Alarm description is structured as follows:

Alarm Description

Impact on System

Failure Identification Strategy (if applicable)

Corrective Actions.

1.4.3 Alarm Definition

1.4.3.1 BannerEach BSS alarm definition starts with an identification banner which allows thelocation of the appropriate definition. It takes the form:

[36, 7] TRUNK - LOS

1.4.3.2 eventTypeThe eventType attribute identifies the basic type of the alarm. Table 1 describesthe event Types.

1.4.3.3 specificProblemsThe specificProblems provides the alarm class name.

1.4.3.4 probableCauseThis attribute provides additional information as to the probable cause ofthe alarm. Its value belongs to a set of possible values either defined inrecommendation X.721 (for those that have a wide applicability) or defined fora particular TMN project.

3BK 21265 AAAA PCZZA Ed.02 13 / 110

1 Introduction

1.4.3.5 perceivedSeverityThis attribute gives the severity level of the alarm. Table 2 describes theseverity level.

The table below provides a mapping between the severity level shown inAS and at the LMT.

MO Severity LMT Category

Critical VPMA, SA

Major PMA

Minor DMA

Warning MI

Table 4: Mapping of MO Perceived Severity to LMT Category

1.4.4 Alarm Description

1.4.4.1 Alarm DescriptionThe Alarm Description describes the alarm and, where appropriate, thedifferences to the default perceived severities.

1.4.4.2 Impact on TelecomThis field describes the impact on the Telecom system behavior. It alsocontains a table indicating which part of the system is affected by the fault interms of loss, degradation or none.

For example, if a cell is affected, the cell column in the table contains a tick ( ) ineither the Loss or Degradation row. The tick can be doubled in any one column( ), indicating the primary impact of the alarm. If the column has a tick in theNone row, that part of the system is unaffected by the fault. For different impactcases (redundancy, diversity, etc.) more symbols, like ladders (#), are used.

The table indicates the worst case, even though redundancy may be provided.

1.4.4.3 Impact on SystemThe impact on the system is defined in terms of Telecom and/or O&M.;

14 / 110 3BK 21265 AAAA PCZZA Ed.02

1 Introduction

1.4.4.4 Failure Identification StrategySometimes more information is necessary to determine the precise fault. TheFailure Identification Strategy lists the checks and tests to perform to obtainthis information.

The additional data is gathered from:

Diagnosis/tests to be applied - appropriate on-site or remote diagnostic and

test procedures to perform

Complex system alarm correlation - other checks that can provide moreinformation about the fault.

Checks that determine whether:

The failure is provoked by a problem external to the reporting unit

Multiple or repetitive failures are reported by one or more similar SBLs

The performance of the affected subsystem is degraded. Newperformance measurements can be compared with previous

measurements.

Resource and data verification - checks that determine whether:

Hardware is serviceable or available. The items checked are passive

items, such as cables, links and boards that do not report their state, andempty slots in subracks

Software versions and parameter settings are correct.

1.4.4.5 Corrective ActionsA description of the recovery actions to be performed by the operator ormaintenance staff. The recovery actions are based on the information providedby the alarm message or the results of diagnostic actions.

To solve the alarm, a graphical flowchart is used. It shows the required checks,tests and actions to be performed to determine the fault and to solve thealarm. The figure below shows an example of a flowchart and describesthe different flowchart fields.

Click on a dedicated action field to display the detailed description of the task.

Some alarms provide additional information. If it is displayed as a text message,the original information from the BSS has been decoded.

3BK 21265 AAAA PCZZA Ed.02 15 / 110

1 Introduction

[32,0] CONV

Alarmsolved

yesConverteroperational?

no

On−site

ContactSystem Support

Restart faulty converter by disengaging/engaging RIT

Identify the faulty DC/DC converter indicated by red illuminated LED.

On−site

On−site

Replace BSC RIT

Alarmsolved

yesConverteroperational?

no

Start field with alarm numberand alarm name

On−site action fields

Decision field

On−site action fields

Decision field

End Field

Figure 1: Graphical Flowchart for Corrective Actions

If the additional information is not decoded, it is displayed as pairs ofhexadecimal digits. At the BSC terminal, the additional information consistsof numbers in the range 0 to 255. Each number represents the contentsof one pair of digits.

Decoding Additional Information from AlarmsDecoding BSC additional information must only be attempted by Alcatel-Lucentsystem support personnel.If a fault persists after corrective actions have been taken, send a copy of thealarm message containing the additional information to the Alcatel-LucentSystem Support office.

16 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2 Class 66: TSC_TRUNK Alarms

This section defines the BSC alarms for the Class 66: TSC_TRUNK alarmclass.

3BK 21265 AAAA PCZZA Ed.02 17 / 110

2 Class 66: TSC_TRUNK Alarms

2.1 [66,22] LOOP-TO-EQUIP

specificProblems TSC_TRUNK [66] LOOP-TO-EQUIP [22]

Event Type equipment

probableCause equipmentUnderTest

perceivedSeverity major

Alarm Description An external loop is closed on an interface

Applicability MT120

Impact on System See Consequences of an SBL State ChangeIT - The link between thetwo submultiplexers is functioning correctly.FLT - Loss of link betweenthe two submultiplexers.OPR The alarm reporting on the transmissionlink is disabled.

Impact BSS O&M; Capabilities

Loss Yes Yes

Degradation – –

2.1.1 Corrective Action

[66,22] LOOP−TO−EQUIP

Remove the loopback settings, though normal conditions return

after a preset control timeout.

Alarmsolved

yes

Alarm persists?

no

ContactSystem Support

18 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.2 [66,50] TWO-MB-MISSING

specificProblems TSC_TRUNK [66] TWO-MB-MISSING [50]

Event Type communication

probableCause lossOfSignal

perceivedSeverity major

Alarm Description Loss of Incoming Signal

Applicability MT120

Impact on System See Consequences of an SBL State ChangeIT - The link between thetwo submultiplexers is functioning correctly.FLT - Loss of link betweenthe two submultiplexers.OPR - The alarm reporting on the transmissionlink is disabled.

Impact BSS O&M; Capabilities

Loss Yes Yes

Degradation – –

3BK 21265 AAAA PCZZA Ed.02 19 / 110

2 Class 66: TSC_TRUNK Alarms

2.2.1 Corrective Action

[66,50] TWO−MB−MISSING

Solve thatalarm(s) first

Solve that alarm(s)

ContactSystem Support

ABIS/APCM/ATER alarm

events?

no

yes

Repair/replace Receiver

2M link−related

alarm events?

no

yes

On−site

Alarmsolved

Alarm persists?

noyes

Alarm persists?

no

yes

Receiver operational?

no yes

Solve that alarm(s)Related

receiver alarm events?

no

yes

Local trunk cabling

OK?

no

yes

Trigger remote signal path and transmitter tests on MSC side

20 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.3 [66,66] AIS-2-MB

specificProblems TSC_TRUNK [66] AIS-2-MB [66]

Event Type communication

probableCause localNodeTransmissionError

perceivedSeverity minor

Alarm Description 2 Mbit/s interface is receiving AIS signal (All ones Indication)

Applicability MT120

Impact on System See Consequences of an SBL State ChangeIT - The link between thetwo submultiplexers is functioning correctly.FLT - Loss of link betweenthe two submultiplexers.OPR - The alarm reporting on the transmissionlink is disabled.

Impact BSS O&M; Capabilities

Loss Yes Yes

Degradation – –

3BK 21265 AAAA PCZZA Ed.02 21 / 110

2 Class 66: TSC_TRUNK Alarms

2.3.1 Corrective Action

[66,66] AIS−2−MB

Remove loop

Solve that alarm(s)

Contact

System Support

ABIS/

APCM/ATER alarm

events?

no

yes

Loop

activated?

no

yes

Alarm

solved

Alarm

persists?

no

yes

Alarm

solved

Alarm

persists?

no

yes

Trigger remote signal

path and transmitter

tests on MSC side

22 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.4 [66,81] FRAME-ALIGNMENT

specificProblems TSC_TRUNK [66] FRAME-ALIGNMENT [81]

Event Type communication

probableCause lossOfFrame

perceivedSeverity major

Alarm Description Loss of frame alignment

Applicability MT120

Impact on System See Consequences of an SBL State ChangeIT - The telecom linkbetween the TC and the MSC is functioning correctly.FIT - Degradationin the telecom and O&M link between the TC and the MSC.FLT - Lossof telecom and O&M link between the TC and the MSC.OPR - Thealarm reporting on the transmission link is disabled.

Impact BSS O&M; Capabilities

Loss Yes Yes

Degradation – –

3BK 21265 AAAA PCZZA Ed.02 23 / 110

2 Class 66: TSC_TRUNK Alarms

2.4.1 Corrective Action

[66,81] FRAME−ALIGNMENT

Correct timeslot 0 settings

Solve that alarm(s)

ContactSystem Support

ABIS/APCM/ATER alarm

events?

no

yes

Timeslot 0 settings

OK?

no

yes

Alarm persists?

no

Alarmsolved

Alarm persists?

no

yes

Trigger remote signal path and transmitter tests on MSC side

yes

24 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.5 [66,86] CRC-MFRAME-ALGN

specificProblems TSC_TRUNK [66] CRC-MFRAME-ALGN [86]

Event Type communication

probableCause lossOfFrame

perceivedSeverity major

Alarm Description Loss of CRC multiframe alignment

Applicability MT120

Impact on System See Consequences of an SBL State ChangeIT - The link between thetwo submultiplexers is functioning correctly.FLT - Loss of link betweenthe two submultiplexers.OPR - The alarm reporting on the transmissionlink is disabled.

Impact BSS O&M; Capabilities

Loss Yes No

Degradation – –

3BK 21265 AAAA PCZZA Ed.02 25 / 110

2 Class 66: TSC_TRUNK Alarms

2.5.1 Corrective Action

[66,86] CRC−MFRAME−ALIGNMENT

Correct timeslot 0 CRC settings

ContactSystem Support

Timeslot 0 CRC settings

OK?

no

yes

Alarm persists?

no

yes

Alarmsolved

Alarm persists?

no

yes

Trigger tests of remote CRC activation on MSC side

26 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.6 [66,99] BER-10E-3

specificProblems TSC_TRUNK [66] BER-10E-3 [99]

Event Type communication

probableCause degradedSignal

perceivedSeverity major

Alarm Description Error rate > E-3

Applicability MT120

Impact on System See Consequences of an SBL State ChangeIT - The link between thetwo submultiplexers is functioning correctly.FLT - Loss of link betweenthe two submultiplexers.OPR - The alarm reporting on the transmissionlink is disabled.

Impact BSS O&M; Capabilities

Loss Yes No

Degradation – –

3BK 21265 AAAA PCZZA Ed.02 27 / 110

2 Class 66: TSC_TRUNK Alarms

2.6.1 Corrective Action

[66,99] BER−10E−3

Solve thatalarm(s) first

Solve that alarm(s)

ContactSystem Support

ABIS/APCM/ATER alarm

events?

no

yes

Repair/replace Receiver

Link−relatedalarm events?

no

yes

On−site

Alarm persists?

noyes

Alarmsolved

Alarm persists?

no

yes

Receiver operational?

no yes

Solve that alarm(s)

Related receiver alarm

events?

no

yes

Local trunk cabling

OK?

no

yes

Trigger remote signal path and transmitter tests on MSC side

28 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.7 [66,100] BER-10E-4

specificProblems TSC_TRUNK [66] BER-10E-4 [100]

Event Type communication

probableCause degradedSignal

perceivedSeverity minor

Alarm Description Error rate > E-4

Applicability MT120

Impact on System See Consequences of an SBL State ChangeIT - The link between thetwo submultiplexers is functioning correctly.FLT - Loss of link betweenthe two submultiplexers.OPR - The alarm reporting on the transmissionlink is disabled.

Impact BSS O&M; Capabilities

Loss No No

Degradation – –

3BK 21265 AAAA PCZZA Ed.02 29 / 110

2 Class 66: TSC_TRUNK Alarms

2.7.1 Corrective Action

[66,100] BER−10E−4

Solve thatalarm(s) first

Solve that alarm(s)

ContactSystem Support

ABIS/APCM/ATER alarm

events?

no

yes

Repair/replace Receiver

Link−relatedalarm events?

no

yes

On−site

Alarm persists?

noyes

Alarmsolved

Alarm persists?

no

yes

Receiver operational?

no yes

Solve that alarm(s)Related

receiver alarm events?

no

yes

Localtrunk cabling

OK?

no

yes

Trigger remote signal path and transmitter tests on MSC side

30 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.8 [66,102] BER-10E-6

specificProblems TSC_TRUNK [66] BER-10E-6 [102]

Event Type communication

probableCause degradedSignal

perceivedSeverity minor

Alarm Description Error rate > E-6

Applicability MT120

Impact on System See Consequences of an SBL State ChangeIT - The link between thetwo submultiplexers is functioning correctly.FLT - Loss of link betweenthe two submultiplexers.OPR - The alarm reporting on the transmissionlink is disabled.

Impact BSS O&M; Capabilities

Loss No No

Degradation – –

3BK 21265 AAAA PCZZA Ed.02 31 / 110

2 Class 66: TSC_TRUNK Alarms

2.8.1 Corrective Action

[66,102] BER−10E−6

Solve thatalarm(s) first

Solve that alarm(s)

ContactSystem Support

ABIS/APCM/ATER alarm

events?

no

yes

Repair/replace Receiver

Link−relatedalarm events?

no

yes

On−site

Alarm persists?

noyes

Alarmsolved

Alarm persists?

no

yes

Receiver operational?

no yes

Solve that alarm(s)Related

receiver alarm events?

no

yes

Local trunk cabling

OK?

no

yes

Trigger remote signal path and transmitter tests on MSC side

32 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.9 [66,176] FAR-END-ALARM

specificProblems TSC_TRUNK [66] FAR-END-ALARM [176]

Event Type communication

probableCause localNodeTransmissionError

perceivedSeverity minor

Alarm Description Remote Alarm Indication

Applicability MT120

Impact on System See Consequences of an SBL State Change.IT - The link between thetwo submultiplexers is functioning correctly.FLT - Loss of link betweenthe two submultiplexers.OPR - The alarm reporting on the transmissionlink is disabled.

Impact BSS O&M; Capabilities

Loss Yes No

Degradation – –

3BK 21265 AAAA PCZZA Ed.02 33 / 110

2 Class 66: TSC_TRUNK Alarms

2.9.1 Corrective Action

[66,176] FAR−END−

ALARM

Solve that alarm(s)

Contact

System Support

ABIS/

APCM/ATER alarm

events?

no

yes

Alarm

solved

Alarm

persists?

no

yes

Solve that alarm(s)

Related

receiver alarm

events?

no

yes

Trigger remote signal

path and transmitter

tests on MSC side

34 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.10 [66,210] TRANS-FLT

specificProblems TSC_TRUNK [66] TRANS-FLT [210]

Event Type equipment

probableCause equipmentMalfunction

perceivedSeverity indeterminate

Alarm Description For each PCM event, a counter is increased

Applicability MT120

Impact on System See Consequences of an SBL State Change.IT - The telecom linkbetween the TC and the MSC is functioning correctly.FIT - Degradationin the telecom and O&M link between the TC and the MSC.FLT - Lossof telecom and O&M link between the TC and the MSC.OPR - Thealarm reporting on the transmission link is disabled.

Impact BSS O&M; Capabilities

Loss No No

Degradation – –

3BK 21265 AAAA PCZZA Ed.02 35 / 110

2 Class 66: TSC_TRUNK Alarms

2.10.1 Corrective Action

[66,210] TRANS−FLT

Solve thatalarm(s) first

Solve that alarm(s)

ContactSystem Support

ABIS/APCM/ATER alarm

events?

no

yes

Repair/replace Receiver

Link−relatedalarm events?

no

yes

On−site

Alarm persists?

noyes

Alarmsolved

Alarm persists?

no

yes

Receiver operational?

no yes

Solve that alarm(s)Related

receiver alarm events?

no

yes

Local trunk cabling

OK?

no

yes

Trigger remote signal path and transmitter tests on MSC side

36 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.11 [66,211] LOSS-OF-CLK-2M

specificProblems TSC_TRUNK [66] LOSS-OF-CLK-2M [211]

Event Type equipment

probableCause timingProblem

perceivedSeverity minor

Alarm Description Loss of clock 2Mhz. The next clock source is selected if available

Applicability MT120

Impact on System See Consequences of an SBL State Change.IT - The telecom linkbetween the TC and the MSC is functioning correctly.FIT - Degradationin the telecom and O&M link between the TC and the MSC.FLT - Lossof telecom and O&M link between the TC and the MSC.OPR - Thealarm reporting on the transmission link is disabled.

Impact BSS O&M; Capabilities

Loss Yes No

Degradation – –

3BK 21265 AAAA PCZZA Ed.02 37 / 110

2 Class 66: TSC_TRUNK Alarms

2.11.1 Corrective Action

[66,211] LOSS−OF−CLOCK−2M

Solve thatalarm(s) first

Solve that alarm(s)

ContactSystem Support

ABIS/APCM/ATER alarm

events?

no

yes

Repair/replace Receiver

Link−relatedalarm events?

no

yes

On−site Alarm persists?

noyes

Alarmsolved

Alarm persists?

no

yes

Receiver operational?

no yes

Solve that alarm(s)Related

receiver alarm events?

no

yes

Local trunk cabling

OK?

no

yes

Trigger remote signal path and transmitter tests on MSC side

38 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.12 [66,231] E1-AIS-2-MB

specificProblems TSC_TRUNK [66] E1-AIS-2-MB [231]

Event Type communication

probableCause remoteAlarmInterface

perceivedSeverity minor

Alarm Description Alarm Indication Signal

Applicability STM-1

Impact on System See Consequences of an SBL State ChangeIT - The link between thetwo submultiplexers is functioning correctly.FLT - Loss of link betweenthe two submultiplexers.OPR - The alarm reporting on the transmissionlink is disabled.

Impact BSS O&M; Capabilities

Loss Yes No

Degradation No No

3BK 21265 AAAA PCZZA Ed.02 39 / 110

2 Class 66: TSC_TRUNK Alarms

2.12.1 Corrective Action

[66, 231] AIS−2−MB

Remove loop

Solve that alarm(s)

ContactSystem Support

ABIS/APCM/ATER alarm

events?

no

yes

Loop activated?

no

yes

Alarmsolved

Alarm persists?

no

yes

Alarmsolved

Alarm persists?

no

yes

Trigger remote signal path and transmitter tests on MSC side

40 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.13 [66,232] E1-FRAME-ALIGNMENT

specificProblems TSC_TRUNK [66] E1-FRAME-ALIGNMENT [232]

Event Type communication

probableCause lossOfFrame

perceivedSeverity major

Alarm Description Loss of Frame Alignment

Applicability STM-1

Impact on System See Consequences of an SBL State ChangeIT - The link between thetwo submultiplexers is functioning correctly.FLT - Loss of link betweenthe two submultiplexers.OPR - The alarm reporting on the transmissionlink is disabled.

Impact BSS O&M; Capabilities

Loss Yes No

Degradation No No

3BK 21265 AAAA PCZZA Ed.02 41 / 110

2 Class 66: TSC_TRUNK Alarms

2.13.1 Corrective Action

[66, 232] E1 FRAME−ALIGNMENT

Correct timeslot 0 settings

Solve that alarm(s)

ContactSystem Support

ABIS/APCM/ATER alarm

events?

no

yes

Timeslot 0 settings

OK?

no

yes

Alarm persists?

no

Alarmsolved

Alarm persists?

no

yes

Trigger remote signal path and transmitter tests on MSC side

yes

42 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.14 [66,233] E1-CRC-MFRAME-ALGN

specificProblems TSC_TRUNK [66] E1-CRC-MFRAME-ALGN [233]

Event Type communication

probableCause lossOfMultiFrame

perceivedSeverity major

Alarm Description Loss of CRC-4 Multiframe Alignment

Applicability STM-1

Impact on System See Consequences of an SBL State ChangeIT - The link between thetwo submultiplexers is functioning correctly.FLT - Loss of link betweenthe two submultiplexers.OPR - The alarm reporting on the transmissionlink is disabled.

Impact BSS O&M; Capabilities

Loss Yes No

Degradation No No

3BK 21265 AAAA PCZZA Ed.02 43 / 110

2 Class 66: TSC_TRUNK Alarms

2.14.1 Corrective Action

[66, 233] E1 CRC−MFRAME−ALIGNMENT

Correct timeslot 0 CRC settings

ContactSystem Support

Timeslot 0 CRC settings

OK?

no

yes

Alarm persists?

no

yes

Alarmsolved

Alarm persists?

no

yes

Trigger tests of remote CRC activation

on MSC side

44 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.15 [66,234] E1-BER-10E-3

specificProblems TSC_TRUNK [66] E1-BER-10E-3 [234]

Event Type communication

probableCause degradedSignal

perceivedSeverity major

Alarm Description Bit Error Rate 10E-3

Applicability STM-1

Impact on System See Consequences of an SBL State ChangeIT - The telecom linkbetween the TC and the MSC is functioning correctly.FIT - Degradationin the telecom and O&M link between the TC and the MSC.FLT - Lossof telecom and O&M link between the TC and the MSC.OPR - Thealarm reporting on the transmission link is disabled.

Impact BSS O&M; Capabilities

Loss Yes No

Degradation No No

3BK 21265 AAAA PCZZA Ed.02 45 / 110

2 Class 66: TSC_TRUNK Alarms

2.15.1 Corrective Action

[66, 234] E1 BER−10E−3

Solve thatalarm(s) first

Solve that alarm(s)

ContactSystem Support

ABIS/APCM/ATER alarm

events?

no

yes

Repair/replace Receiver

Link−relatedalarm events?

no

yes

On−site

Alarm persists?

noyes

Alarmsolved

Alarm persists?

no

yes

Receiver operational?

no yes

Solve that alarm(s)Related

receiver alarm events?

no

yes

Local trunk cabling

OK?

no

yes

Trigger remote signal path and transmitter tests on MSC side

46 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.16 [66,235] E1-BER-10E-4

specificProblems TSC_TRUNK [66] E1-BER-10E-4 [235]

Event Type communication

probableCause degradedSignal

perceivedSeverity minor

Alarm Description Bit Error Rate 10E-4

Applicability STM-1

Impact on System See Consequences of an SBL State ChangeIT - The link between thetwo submultiplexers is functioning correctly.FLT - Loss of link betweenthe two submultiplexers.OPR - The alarm reporting on the transmissionlink is disabled.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3BK 21265 AAAA PCZZA Ed.02 47 / 110

2 Class 66: TSC_TRUNK Alarms

2.16.1 Corrective Action

[66, 235] E1 BER−10E−4

Solve thatalarm(s) first

Solve that alarm(s)

ContactSystem Support

ABIS/APCM/ATER alarm

events?

no

yes

Repair/replace Receiver

Link−relatedalarm events?

no

yes

On−site

Alarm persists?

noyes

Alarmsolved

Alarm persists?

no

yes

Receiver operational?

no yes

Solve that alarm(s)Related

receiver alarm events?

no

yes

Localtrunk cabling

OK?

no

yes

Trigger remote signal path and transmitter tests on MSC side

48 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.17 [66,236] E1-RAI

specificProblems TSC_TRUNK [66] E1-RAI [236]

Event Type communication

probableCause remoteAlarmInterface

perceivedSeverity minor

Alarm Description Remote Alarm Indication

Applicability STM-1

Impact on System Whenever a failure occurs, the trunk is autonomously disabled.Blockingand release of all associated A-channels is carried out.RAI is the signalsent on the E1 by a remote transmission node as a response to thedetection of a fatal transmission fault (AIS, LIS, LFA.).This is the TCview of transmission, please check for transmission alarms.

Impact BSS O&M; Capabilities

Loss – –

Degradation Yes No

2.17.1 Corrective Action

[66, 236] E1−RAI

ContactSystem Support

Alarmsolved

Alarm persists?

no

yes

Check transmission alarms (AIS, LIS, LFA)

3BK 21265 AAAA PCZZA Ed.02 49 / 110

2 Class 66: TSC_TRUNK Alarms

2.18 [66,237] E1-BER-10E-6

specificProblems TSC_TRUNK [66] E1-BER-10E-6 [237]

Event Type communication

probableCause degradedSignal

perceivedSeverity minor

Alarm Description Bit Error Rate 10E-6

Applicability STM-1

Impact on System See Consequences of an SBL State ChangeIT - The telecom linkbetween the TC and the MSC is functioning correctly.FIT - Degradationin the telecom and O&M link between the TC and the MSC.FLT - Lossof telecom and O&M link between the TC and the MSC.OPR - Thealarm reporting on the transmission link is disabled.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

50 / 110 3BK 21265 AAAA PCZZA Ed.02

2 Class 66: TSC_TRUNK Alarms

2.18.1 Corrective Action

[66, 237] E1 BER−10E−6

Solve thatalarm(s) first

Solve that alarm(s)

ContactSystem Support

ABIS/APCM/ATER alarm

events?

no

yes

Repair/replace Receiver

Link−relatedalarm events?

no

yes

On−site

Alarm persists?

noyes

Alarmsolved

Alarm persists?

no

yes

Receiver operational?

no yes

Solve that alarm(s)Related

receiver alarm events?

no

yes

Local trunk cabling

OK?

no

yes

Trigger remote signal path and transmitter tests on MSC side

3BK 21265 AAAA PCZZA Ed.02 51 / 110

2 Class 66: TSC_TRUNK Alarms

52 / 110 3BK 21265 AAAA PCZZA Ed.02

3 Class 102: TC_TRANS Alarms

3 Class 102: TC_TRANS Alarms

This section defines the BSC alarms for the Class 102: TC_TRANS alarm class.

3BK 21265 AAAA PCZZA Ed.02 53 / 110

3 Class 102: TC_TRANS Alarms

3.1 [102,210] SFP_UNEQ

specificProblems TC_TRANS [102] SFP_UNEQ [210]

Event Type communication

probableCause equipmentMalfunction

perceivedSeverity major

Alarm Description Small Form-Factor Pluggable not equipped

Applicability STM-1

Impact on System APS switching (the redundant STM1 link will become active)

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3.1.1 Corrective Action

[102, 210] SFP_UNEQ

Check and repair the standby STM1 link.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

54 / 110 3BK 21265 AAAA PCZZA Ed.02

3 Class 102: TC_TRANS Alarms

3.2 [102,211] RS_LOS

specificProblems TC_TRANS [102] RS_LOS [211]

Event Type communication

probableCause lossOfSignal

perceivedSeverity major

Alarm Description Section Loss Of Signal

Applicability STM-1

Impact on System APS switching (the redundant STM1 link will become active)

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3.2.1 Corrective Action

[102, 211] RS_LOS

Check and repair the standby STM1 link.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

3BK 21265 AAAA PCZZA Ed.02 55 / 110

3 Class 102: TC_TRANS Alarms

3.3 [102,212] RS_LOF

specificProblems TC_TRANS [102] RS_LOF [212]

Event Type communication

probableCause lossOfFrame

perceivedSeverity major

Alarm Description Section Loss Of Frame

Applicability STM-1

Impact on System APS switching (the redundant STM1 link will become active)

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3.3.1 Corrective Action

[102, 212] RS_LOF

Check and repair the standby STM1 link.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

56 / 110 3BK 21265 AAAA PCZZA Ed.02

3 Class 102: TC_TRANS Alarms

3.4 [102,214] MS_AIS

specificProblems TC_TRANS [102] MS_AIS [214]

Event Type communication

probableCause localNodeTransmissionError

perceivedSeverity major

Alarm Description Multiplex Section Alarm Indication Signal

Applicability STM-1

Impact on System APS switching (the redundant STM1 link will become active)

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3.4.1 Corrective Action

[102, 214] MS_AIS

Check and repair the standby STM1 link.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

3BK 21265 AAAA PCZZA Ed.02 57 / 110

3 Class 102: TC_TRANS Alarms

3.5 [102,215] MS_RDI

specificProblems TC_TRANS [102] MS_RDI [215]

Event Type communication

probableCause remoteNodeTransmissionError

perceivedSeverity major

Alarm Description Multiplex Section Remote Defect Indication

Applicability STM-1

Impact on System Physical layer error indicator. STM-1 TTP isunlocked/enabled/degraded. No APS switching foreseen.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3.5.1 Corrective Action

[102, 215] MS_RDI

Check and repair the STM1 link.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

58 / 110 3BK 21265 AAAA PCZZA Ed.02

3 Class 102: TC_TRANS Alarms

3.6 [102,216] MS_SF

specificProblems TC_TRANS [102] MS_SF [216]

Event Type communication

probableCause degradedSignal

perceivedSeverity major

Alarm Description Multiplex Section signal failed Bit Error Rate 10-3

Applicability STM-1

Impact on System APS switching (the redundant STM1 link will become active)

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3.6.1 Corrective Action

[102, 216] MS_SF

Check and repair the standby STM1 link.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

3BK 21265 AAAA PCZZA Ed.02 59 / 110

3 Class 102: TC_TRANS Alarms

3.7 [102,217] MS_SD

specificProblems TC_TRANS [102] MS_SD [217]

Event Type communication

probableCause degradedSignal

perceivedSeverity major

Alarm Description Multiplex Section signal degraded Bit Error Rate 10-6

Applicability STM-1

Impact on System Physical layer error indicator. STM-1 TTP isunlocked/enabled/degraded. No APS switching foreseen.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3.7.1 Corrective Action

[102, 217] MS_SD

Check and repair the STM1 link.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

60 / 110 3BK 21265 AAAA PCZZA Ed.02

3 Class 102: TC_TRANS Alarms

3.8 [102,221] AU_LOP

specificProblems TC_TRANS [102] AU_LOP [221]

Event Type communication

probableCause lossOfPointer

perceivedSeverity major

Alarm Description Administrative Unit 4 Loss of Pointer

Applicability STM-1

Impact on System STM-1 Interface is unlocked/disable/failed.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3.8.1 Corrective Action

[102, 221] AU_LOP

Check and repair the standby STM1 link.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

3BK 21265 AAAA PCZZA Ed.02 61 / 110

3 Class 102: TC_TRANS Alarms

3.9 [102,222] AU_AIS

specificProblems TC_TRANS [102] AU_AIS [222]

Event Type communication

probableCause degradedSignal

perceivedSeverity major

Alarm Description Administrative Unit 4 Alarm Indication Signal

Applicability STM-1

Impact on System STM-1 Interface is unlocked/disable/failed.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3.9.1 Corrective Action

[102, 222] AU_AIS

Check and repair the STM1 link.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

62 / 110 3BK 21265 AAAA PCZZA Ed.02

3 Class 102: TC_TRANS Alarms

3.10 [102,223] SFP_WRONGTYPE

specificProblems TC_TRANS [102] SFP_WRONGTYPE [223]

Event Type equipment

probableCause equipmentMalfunction

perceivedSeverity major

Alarm Description A SFP different from type 1 has been plugged in

Applicability STM-1

Impact on System STM-1 TTP is unlocked/disable/failed. APS switching.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3.10.1 Corrective Action

[102, 223]SFP_WRONGTYPE

Change the SFP connector type with a type 1.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

3BK 21265 AAAA PCZZA Ed.02 63 / 110

3 Class 102: TC_TRANS Alarms

3.11 [102,231] HP_UNEQ

specificProblems TC_TRANS [102] HP_UNEQ [231]

Event Type communication

probableCause equipmentMalfuncton

perceivedSeverity major

Alarm Description High Order Path Unequipped

Applicability STM-1

Impact on System STM-1 Interface is unlocked/disabled/failed.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3.11.1 Corrective Action

[102, 231]HP_UNEQ

Check and repair the STM1 link.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

64 / 110 3BK 21265 AAAA PCZZA Ed.02

3 Class 102: TC_TRANS Alarms

3.12 [102,232] HP_PLM

specificProblems TC_TRANS [102] HP_PLM [232]

Event Type communication

probableCause pathTraceMismatch

perceivedSeverity major

Alarm Description High Order Path Payload Label Mismatch

Applicability STM-1

Impact on System STM-1 Interface is unlocked/disable/failed.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3.12.1 Corrective Action

[102, 232] HP_PLM

Check and repair the STM1 link.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

3BK 21265 AAAA PCZZA Ed.02 65 / 110

3 Class 102: TC_TRANS Alarms

3.13 [102,233] HP_RDI

specificProblems TC_TRANS [102] HP_RDI [233]

Event Type communication

probableCause remoteAlarmInterface

perceivedSeverity major

Alarm Description High Order Path Remote Defect Indication

Applicability STM-1

Impact on System STM-1 Interface is unlocked/enabled/degraded.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3.13.1 Corrective Action

[102, 233] HP_RDI

Check and repair the STM1 link.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

66 / 110 3BK 21265 AAAA PCZZA Ed.02

3 Class 102: TC_TRANS Alarms

3.14 [102,234] HP_LOM

specificProblems TC_TRANS [102] HP_LOM [234]

Event Type communication

probableCause lossOfFrame

perceivedSeverity major

Alarm Description High Order Path Loss of Multiframe

Applicability STM-1

Impact on System STM-1 Interface is unlocked/disable/failed.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3.14.1 Corrective Action

[102, 234] HP_LOM

Check and repair the STM1 link.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

3BK 21265 AAAA PCZZA Ed.02 67 / 110

3 Class 102: TC_TRANS Alarms

68 / 110 3BK 21265 AAAA PCZZA Ed.02

4 Class 103: TC_IF Alarms

4 Class 103: TC_IF Alarms

This section defines the BSC alarms for the Class 103: TC_IF alarm class.

3BK 21265 AAAA PCZZA Ed.02 69 / 110

4 Class 103: TC_IF Alarms

4.1 [103,0] RESET

specificProblems TC_IF [103] RESET [0]

Event Type processingError

probableCause softwareError

perceivedSeverity indeterminate

Alarm Description TCIF board reset. An autonomous reset of a TCIF board occurred.

Applicability TCIF

Impact on System The SBL state remains unchanged.The impact depends on the type ofTCIF state.Standby TCIF: O&M functions are not affected. Telecomfunctions are not affected.Active TCIF: A takeover occurs if the standbyTCIF is IT; the standby TCIF now becomes active. Communicationwith the OMC-R is lost for someseconds. Telecom functions are notaffected.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

4.1.1 Corrective Action

None. The TCIF returns to service automatically.

70 / 110 3BK 21265 AAAA PCZZA Ed.02

4 Class 103: TC_IF Alarms

4.2 [103,1] TAKEOVER

specificProblems TC_IF [103] TAKEOVER [1]

Event Type processingError

probableCause softwareProgramAbnormallyTerminated

perceivedSeverity indeterminate

Alarm Description TCIF Takeover was triggered. There has been a change in the activeTCIF board in the case of an active/standby board pair. The previouslyactive TCIF goes into standby mode. This event is generated onlywhen a takeover occurs.This event is generated also for the STM1takeover in the case of working/protected STM1 pair.

Applicability TCIF

Impact on System The SBL state remains unchanged.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

4.2.1 Corrective Action

None. The TCIF function returns to service automatically.

3BK 21265 AAAA PCZZA Ed.02 71 / 110

4 Class 103: TC_IF Alarms

4.3 [103,2] TAKEOVER_REFUSED

specificProblems TC_IF [103] TAKEOVER_REFUSED [2]

Event Type equipment

probableCause softwareProgramAbnormallyTerminated

perceivedSeverity indeterminate

Alarm Description Sent when the takeover cannot take place because the standby isnot available (failed also, or in unstable state) or because of otherproblems. This event is generated for both TCIF and STM1 cases.

Applicability TCIF

Impact on System The active TCIF will be reset, if the takeover is refused for the Tcifboard. In case of STM1 takeover refused, the traffic is lost for thatSTM1 interface.

Impact BSS O&M; Capabilities

Loss No No

Degradation Yes Yes

4.3.1 Corrective Action

[103, 2] TAKEOVER REFUSED

Check and repair the status of the

Stanby TCIF board.

Alarmsolved

yes

Alarm persists?

no

ContactSystem Support

72 / 110 3BK 21265 AAAA PCZZA Ed.02

4 Class 103: TC_IF Alarms

4.4 [103,4] ACCESS_FAIL

specificProblems TC_IF [103] ACCESS_FAIL [4]

Event Type equipment

probableCause softwareProgramAbnormallyTerminated

perceivedSeverity indeterminate

Alarm Description Communication problem between the active and the standby TCIFboards

Applicability TCIF

Impact on System Contact with the standby TCIF has been lost.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

4.4.1 Corrective Action

[103, 4] ACCESS FAIL

Test both TCIF internal ethernet connections.

Alarmsolved

yes

Alarm persists?

no

ContactSystem Support

3BK 21265 AAAA PCZZA Ed.02 73 / 110

4 Class 103: TC_IF Alarms

4.5 [103,6] UNPLUGGED

specificProblems TC_IF [103] UNPLUGGED [6]

Event Type equipment

probableCause equipmentUnplugged

perceivedSeverity major

Alarm Description TCIF board unplugged. The board was removed from the shelf. Alarmwill be cleared after board re-insertion.

Applicability TCIF

Impact on System There is no system impact if the board is the standby TCIF. If the boardis the active TCIF, then a takeover is triggered.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

4.5.1 Corrective Action

None. The board is unplugged.

74 / 110 3BK 21265 AAAA PCZZA Ed.02

4 Class 103: TC_IF Alarms

4.6 [103,7] HOST_FAILURE

specificProblems TC_IF [103] HOST_FAILURE [7]

Event Type processingError

probableCause equipmentMalfunction

perceivedSeverity critical

Alarm Description TCIF control function failure

Applicability TCIF

Impact on System TCIF internal processes are affected. If the alarm is raised on theactive TCIF, the O&M function of the TCIF to supervise the MT120boards is lost (for all the MT120 boards supervised by this TCIF)

Impact BSS O&M; Capabilities

Loss No Yes

Degradation No Yes

4.6.1 Corrective Action

[103, 7] HOST_FAILURE

Reset TCIF board.

Alarmsolved

yes

Alarm persists?

no

ContactSystem Support

3BK 21265 AAAA PCZZA Ed.02 75 / 110

4 Class 103: TC_IF Alarms

4.7 [103,10] HW_FAULT_FATAL

specificProblems TC_IF [103] HW_FAULT_FATAL [10]

Event Type equipment

probableCause equipmentMalfunction

perceivedSeverity critical

Alarm Description Fatal HW failure on TCIF

Applicability TCIF

Impact on System A fatal HW failure occurs.The impacted TCIF SBL state is changed toFOS. If the alarm appears on the active TCIF a takeover is triggered.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

4.7.1 Corrective Action

[103, 10] HW_FAULT_FATAL

Replace the faulty board.

Alarmsolved

yes

Alarm persists?

no

ContactSystem Support

76 / 110 3BK 21265 AAAA PCZZA Ed.02

4 Class 103: TC_IF Alarms

4.8 [103,11] TEMPERATURE_FATAL

specificProblems TC_IF [103] TEMPERATURE_FATAL [11]

Event Type equipment

probableCause temperatureUnacceptable

perceivedSeverity critical

Alarm Description Fatal temperature over-heat. Hardware or environmental fatal alarm.Temperature of the unit is over the "critical" threshold.

Applicability TCIF

Impact on System The board is powered off and the impacted SBL is set to FOS. A TCIFtakeover occurs, if the alarm appears on the active TCIF board. Thereis no other system impact.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

4.8.1 Corrective Action

[103, 11] TEMPERATURE_FATAL

Check the FAN module integrity and environment.

Alarmsolved

yes

Alarm persists?

no

ContactSystem Support

3BK 21265 AAAA PCZZA Ed.02 77 / 110

4 Class 103: TC_IF Alarms

4.9 [103,12] TEMPERATURE_MAJOR

specificProblems TC_IF [103] TEMPERATURE_MAJOR [12]

Event Type equipment

probableCause temperatureUnacceptable

perceivedSeverity major

Alarm Description High temperature over-heat. Hardware or environmental major alarm.Temperature of the unit is over the "major" threshold. That may impactthe functional status.

Applicability TCIF

Impact on System The impacted SBL is set to FLT. A takeover occurs, if the alarmsappears on the active Tcif board. The faulty board is reset.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

78 / 110 3BK 21265 AAAA PCZZA Ed.02

4 Class 103: TC_IF Alarms

4.9.1 Corrective Action

[103, 12] TEMPERATURE_MAJOR

Check the FAN module integrity and environment.

Alarmsolved

yes

Alarm persists?

no

ContactSystem Support

Reset the board.

Alarm persists?

no

yes

3BK 21265 AAAA PCZZA Ed.02 79 / 110

4 Class 103: TC_IF Alarms

4.10 [103,13] TEMPERATURE_MINOR

specificProblems TC_IF [103] TEMPERATURE_MINOR [13]

Event Type equipment

probableCause temperatureUnacceptable

perceivedSeverity minor

Alarm Description Non-Fatal temperature over-heat. Hardware or environmental minoralarm. Temperature of the unit is over the "minor" threshold. Thefunctional status is not impacted.

Applicability TCIF

Impact on System The impacted SBL is set to FIT. There is no other system impact.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

4.10.1 Corrective Action

[103, 13] TEMPERATURE_MINOR

Check the FAN module integrity and environment.

Alarmsolved

yes

ContactSystem Support

Alarm persists?

no

80 / 110 3BK 21265 AAAA PCZZA Ed.02

4 Class 103: TC_IF Alarms

4.11 [103,14] VOLTAGE_FATAL

specificProblems TC_IF [103] VOLTAGE_FATAL [14]

Event Type equipment

probableCause powerProblem

perceivedSeverity critical

Alarm Description Power supply voltage is over critical threshold. The functional status isimpacted and the board is powered off.

Applicability TCIF

Impact on System The board is powered off and the impacted SBL is set to FOS. A TCIFtakeover occurs, if the alarm appears on the active TCIF board. Thereis no other system impact.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3BK 21265 AAAA PCZZA Ed.02 81 / 110

4 Class 103: TC_IF Alarms

4.11.1 Corrective Action

[103, 14] VOLTAGE_FATAL

Check the TC rack breaker.

Alarmsolved

yes

ContactSystem Support

Alarm persists?

no

Replace the TCIF board

Alarm persists?

no

yes

82 / 110 3BK 21265 AAAA PCZZA Ed.02

4 Class 103: TC_IF Alarms

4.12 [103,15] VOLTAGE_MAJOR

specificProblems TC_IF [103] VOLTAGE_MAJOR [15]

Event Type equipment

probableCause powerProblem

perceivedSeverity major

Alarm Description Power supply voltage is over major threshold. The functional statusmay be impacted.The power status is severely degraded.

Applicability TCIF

Impact on System The impacted SBL is set to FLT. A takeover occurs in case of faultyactive Tcif and the faulty board is reset.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3BK 21265 AAAA PCZZA Ed.02 83 / 110

4 Class 103: TC_IF Alarms

4.12.1 Corrective Action

[103, 15] VOLTAGE_MAJOR

Check the TC rack breaker.

Alarmsolved

yes

ContactSystem Support

Alarm persists?

no

Replace the TCIF board

Alarm persists?

no

yes

84 / 110 3BK 21265 AAAA PCZZA Ed.02

4 Class 103: TC_IF Alarms

4.13 [103,16] VOLTAGE_MINOR

specificProblems TC_IF [103] VOLTAGE_MINOR [16]

Event Type equipment

probableCause powerProblem

perceivedSeverity minor

Alarm Description Power supply voltage is over minor threshold. The functional status isnot impacted. The power status is degraded.

Applicability TCIF

Impact on System The impacted SBL is set to FIT. There is no other system impact.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3BK 21265 AAAA PCZZA Ed.02 85 / 110

4 Class 103: TC_IF Alarms

4.13.1 Corrective Action

[103, 16] VOLTAGE_MINOR

Check the TC rack breaker.

Alarmsolved

yes

ContactSystem Support

Alarm persists?

no

Replace the TCIF board

Alarm persists?

no

yes

86 / 110 3BK 21265 AAAA PCZZA Ed.02

4 Class 103: TC_IF Alarms

4.14 [103,17] RLC_OV

specificProblems TC_IF [103] RLC_OV [17]

Event Type processingError

probableCause softwareError

perceivedSeverity critical

Alarm Description The board has reset more then 3 times in 1 hour

Applicability TCIF

Impact on System The board is powered off and the impacted SBL is set to FOS.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3BK 21265 AAAA PCZZA Ed.02 87 / 110

4 Class 103: TC_IF Alarms

4.14.1 Corrective Action

[103, 17] RLC_OV

Unplug and Plug again the faulty TCIF board.

Alarmsolved

yes

ContactSystem Support

Alarm persists?

no

Replace the TCIF board

Alarm persists?

no

yes

88 / 110 3BK 21265 AAAA PCZZA Ed.02

4 Class 103: TC_IF Alarms

4.15 [103,19] OBC_OVERLOADING

specificProblems TC_IF [103] OBC_OVERLOADING [19]

Event Type processingError

probableCause equipmentMalfunction

perceivedSeverity minor

Alarm Description TCIF OnBoardControler processor overloaded

Applicability TCIF

Impact on System The impacted TCIF SBL state is changed to FIT.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

3BK 21265 AAAA PCZZA Ed.02 89 / 110

4 Class 103: TC_IF Alarms

4.15.1 Corrective Action

[103, 19] OBC_OVERLOADING

Reset the board.

Alarmsolved

yes

ContactSystem Support

Alarm persists?

no

Replace the TCIF board

Alarm persists?

no

yes

90 / 110 3BK 21265 AAAA PCZZA Ed.02

4 Class 103: TC_IF Alarms

4.16 [103,20] PROCESS_TERMINATION_FATAL

specificProblems TC_IF [103] PROCESS_TERMINATION_FATAL [20]

Event Type processingError

probableCause softwareProgramAbnormallyTerminated

perceivedSeverity indeterminate

Alarm Description TCIF fatal process termination

Applicability TCIF

Impact on System The impacted Tcif will be reset.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

4.16.1 Corrective Action

[103, 20] PROCESS_TERMINATION_FATAL

Check and repair the status of the

TCIF board.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

3BK 21265 AAAA PCZZA Ed.02 91 / 110

4 Class 103: TC_IF Alarms

4.17 [103,23] HSI_FAILURE

specificProblems TC_IF [103] HSI_FAILURE [23]

Event Type communication

probableCause softwareError

perceivedSeverity major

Alarm Description Failure on the HSI link between the Tcif and the MT120 boards

Applicability TCIF

Impact on System HSI links toward MT120 boards are down.

Impact BSS O&M; Capabilities

Loss No Yes - lost for theO&M actions on thesupervised MT120boards

Degradation No Yes

92 / 110 3BK 21265 AAAA PCZZA Ed.02

4 Class 103: TC_IF Alarms

4.17.1 Corrective Action

[103, 23] HSI_FAILURE

Check the integrity of the HSI connectors and HSI cables

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

Reset TCIF board.

Alarm persists?

no

Reset TCIF board.

Alarm persists?

no

yes

yes

3BK 21265 AAAA PCZZA Ed.02 93 / 110

4 Class 103: TC_IF Alarms

4.18 [103,24] FAN_FAILURE

specificProblems TC_IF [103] FAN_FAILURE [24]

Event Type equipment

probableCause equipmentMalfunction

perceivedSeverity major

Alarm Description TCIF Fan failure. One of the chassiss fan units has failed. The platformis still running.

Applicability TCIF

Impact on System The impacted SBL is set to FLT. There is no other system impact.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

4.18.1 Corrective Action

[103, 24] FAN_FAILURE

Replace the impacted FAN

module.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

94 / 110 3BK 21265 AAAA PCZZA Ed.02

4 Class 103: TC_IF Alarms

4.19 [103,28] INTERNAL_CLOCK_INCONSYSTENCY

specificProblems TC_IF [103] INTERNAL_CLOCK_INCONSYSTENCY [28]

Event Type equipment

probableCause timingProblem

perceivedSeverity minor

Alarm Description Internal TCIF clock inconsistencies

Applicability TCIF

Impact on System Impacted SBLs are in FIT.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

4.19.1 Corrective Action

[103, 28] INTERNAL_CLOCK_INCONSYSTENCY

Reset the TCIF board.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

3BK 21265 AAAA PCZZA Ed.02 95 / 110

4 Class 103: TC_IF Alarms

4.20 [103,29] POWER_SUPPLY

specificProblems TC_IF [103] POWER_SUPPLY [29]

Event Type environment

probableCause powerProblem

perceivedSeverity major

Alarm Description Power problem

Applicability TCIF

Impact on System One power suply is down.

Impact BSS O&M; Capabilities

Loss No No

Degradation No No

4.20.1 Corrective Action

[103, 29] POWER_SUPPLY

Check the TC rack breaker.

Alarmsolved

ContactSystem Support

Alarm persists?

no

yes

96 / 110 3BK 21265 AAAA PCZZA Ed.02

5 Class 105: TRANSCODER Alarms

5 Class 105: TRANSCODER Alarms

This section defines the BSC alarms for the Class 105: TRANSCODER alarmclass.

3BK 21265 AAAA PCZZA Ed.02 97 / 110

5 Class 105: TRANSCODER Alarms

5.1 [105,000] POWER-SUPPLY

specificProblems TRANSCODER [105] POWER-SUPPLY [000]

Event Type environment

probableCause powerProblem

perceivedSeverity major

Alarm Description One of both power suply is in fault

Applicability TC G2.5

Impact on System If the power supply fails and the OBC is not working on any board, thepower supply alarm may not be sent.

Impact BSS O&M; Capabilities

Loss No No

Degradation – No

5.1.1 Corrective Action

[105, 0] POWER−SUPPLY

Check the TC power breaker.

Alarmsolved

yes

Alarm persists?

no

ContactSystem Support

98 / 110 3BK 21265 AAAA PCZZA Ed.02

5 Class 105: TRANSCODER Alarms

5.2 [105,128] EQUIPMENT-FAULT(2nd or more DSP faulty - looptest)

specificProblems TRANSCODER [105] EQUIPMENT-FAULT(2nd or more DSP faulty -loop test) [128]

Event Type equipment

probableCause InternalDSPproblem

perceivedSeverity major

Alarm Description Internal fault has been detected on

Applicability MT120

Impact on System See Consequences of an SBL State Change.ACH IT Gain of aterrestrial traffic channel to the MSC. The channel can be used fortraffic.ACH FLT/FOS Causes loss of a terrestrial traffic channel to theMSC. The channel will no longer be used for traffic.

Impact BSS O&M; Capabilities

Loss No No

Degradation Yes No

3BK 21265 AAAA PCZZA Ed.02 99 / 110

5 Class 105: TRANSCODER Alarms

5.2.1 Corrective Action

[105, 128] EQUIPMENT−FAULT(2nd or more

DSP faulty − loop test)

Reset corresponding JBMTE board.

Alarmsolved

yes

Alarm persists?

no

ContactSystem Support

Replace corresponding JBMTE board.

yes

Alarm persists?

no

100 / 110 3BK 21265 AAAA PCZZA Ed.02

5 Class 105: TRANSCODER Alarms

5.3 [105,130] MEMORY-FAULT

specificProblems TRANSCODER [105] MEMORY-FAULT [130]

Event Type processingError

probableCause corruptData

perceivedSeverity major

Alarm Description Fault in memory (unsuccessful write to FLASH memory)

Applicability MT120

Impact on System See Consequences of an SBL State Change.ACH IT - Gain of aterrestrial traffic channel to the MSC. The channel can be used fortraffic.ACH FLT/FOS - Causes loss of a terrestrial traffic channel to theMSC. The channel will no longer be used for traffic.

Impact BSS O&M; Capabilities

Loss No No

Degradation Yes No

3BK 21265 AAAA PCZZA Ed.02 101 / 110

5 Class 105: TRANSCODER Alarms

5.3.1 Corrective Action

105,130] MEMORY−FAULT

Analyze alarm number

Solve that alarm(s)BIU

alarm events?

no

yes

Alarmsolved

Reset MT120

Replace MT120

Alarm persists?

Alarm persists?

ContactSystem Support

no

no

yes

On−site

102 / 110 3BK 21265 AAAA PCZZA Ed.02

5 Class 105: TRANSCODER Alarms

5.4 [105,136] FIRST-DSP-FAIL

specificProblems TRANSCODER [105] FIRST-DSP-FAIL [136]

Event Type equipment

probableCause equipmentMalfunction

perceivedSeverity major

Alarm Description For the 1st time, there is a DSP failure. The MT120 works in degradedmode

Applicability MT120

Impact on System See Consequences of an SBL State Change.ACH IT - Gain of aterrestrial traffic channel to the MSC. The channel can be used fortraffic.The DSP chanel recobery procedure is aplied.

Impact BSS O&M; Capabilities

Loss No No

Degradation Yes No

3BK 21265 AAAA PCZZA Ed.02 103 / 110

5 Class 105: TRANSCODER Alarms

5.4.1 Corrective Action

[105,136] FIRST−DSP−FAIL

ContactSystem Support

Alarmsolved

Alarm persists?

no

yes

On−site

Replace MT120

Alarmsolved

yes

Alarm persists?

no

Reset MT120

104 / 110 3BK 21265 AAAA PCZZA Ed.02

5 Class 105: TRANSCODER Alarms

5.5 [105,148] RESET (1st DSP faulty, 2nd or more DSP faulty-HW watchdog- HW failure- more than 3 autoresets in 24hours.)

specificProblems TRANSCODER [105] RESET (1st DSP faulty, 2nd or more DSP faulty-HW watchdog- HW failure- more than 3 autoresets in 24 hours.) [148]

Event Type processingError

probableCause softwareError

perceivedSeverity indeterminate

Alarm Description Equipment reset, A Reset_Restart buffer is available

Applicability MT120

Impact on System See Consequences of an SBL State Change.ACH IT - Gain of aterrestrial traffic channel to the MSC. The channel can be used fortraffic.ACH FLT/FOS - Causes loss of a terrestrial traffic channel to theMSC. The channel will no longer be used for traffic.

Impact BSS O&M; Capabilities

Loss Yes No

Degradation – No

5.5.1 Corrective Action

None - this alarm reports the autonomous load of the BTS_ADAPT only.

3BK 21265 AAAA PCZZA Ed.02 105 / 110

5 Class 105: TRANSCODER Alarms

5.6 [105,210] TRANS-FLT

specificProblems TRANSCODER [105] TRANS-FLT [210]

Event Type communication

probableCause degradedSignal

perceivedSeverity indeterminate

Alarm Description For each PCM event, a counter is increased and when threshold isexceeded, this alarm is generated.The PCM event counter thresholdvalue is exceeded on one ATER interface, which results in thegeneration of this 2 Mbit/s alarm.

Applicability MT120

Impact on System See Consequences of an SBL State Change.ACH IT - Gain of aterrestrial traffic channel to the MSC. The channel can be used fortraffic.ACH FLT/FOS - Causes loss of a terrestrial traffic channel to theMSC. The channel will no longer be used for traffic.

Impact BSS O&M; Capabilities

Loss No No

Degradation – No

106 / 110 3BK 21265 AAAA PCZZA Ed.02

5 Class 105: TRANSCODER Alarms

5.6.1 Corrective Action

[105,210] ATER−TRANS−FLT

Solve thatalarm(s) first

Solve that alarm(s)

ContactSystem Support

PCM/ATER alarm events?

no

yes

Repair/replace Ater interface

Other Ater alarm

events?

no

yes

On−site

Alarm persists?

noyes

Alarmsolved

Alarm persists?

no

yes

Ater interface

operational?

no yes

Solve that alarm(s)Ater

interface alarm events?

no

yes

Local Ater cabling

OK?

no

yes

Trigger remote signal path and transmitter tests on MSC side

3BK 21265 AAAA PCZZA Ed.02 107 / 110

5 Class 105: TRANSCODER Alarms

5.7 [105,211] LOSS-OF-CLK-2M

specificProblems TRANSCODER [105] LOSS-OF-CLK-2M [211]

Event Type equipment

probableCause timingProblem

perceivedSeverity major

Alarm Description Loss of clock 2Mhz. The next clock source is selected if available

Applicability MT120

Impact on System See Consequences of an SBL State Change.ACH IT - Gain of aterrestrial traffic channel to the MSC. The channel can be used fortraffic.ACH FLT/FOS - Causes loss of a terrestrial traffic channel to theMSC. The channel will no longer be used for traffic.

Impact BSS O&M; Capabilities

Loss No No

Degradation – No

108 / 110 3BK 21265 AAAA PCZZA Ed.02

5 Class 105: TRANSCODER Alarms

5.7.1 Corrective Action

[105,211] LOSS−OF−CLOCK−2M

Solve thatalarm(s) first

Solve that alarm(s)

ContactSystem Support

APCM alarm events?

no

yes

Repair/replace Receiver

Link related alarm

events?

no

yes

Alarm persists?

noyes

Alarmsolved

Alarm persists?

no

yes

Receiver operational?

no yes

Solve that alarm(s)Related

receiver alarm events?

no

yes

Local trunk cabling

OK?

no

yes

Trigger remote signal path and transmitter tests on MSC side

3BK 21265 AAAA PCZZA Ed.02 109 / 110

5 Class 105: TRANSCODER Alarms

5.8 [105,216] RESTART (DSP restart OTP restart)

specificProblems TRANSCODER [105] RESTART (DSP restart OTP restart) [216]

Event Type processingError

probableCause softwareError

perceivedSeverity indeterminate

Alarm Description (Equipment Restart,a Reset_Restart buffer is available)

Applicability MT120

Impact on System See Consequences of an SBL State Change.ACH IT - Gain of aterrestrial traffic channel to the MSC. The channel can be used fortraffic.ACH FLT/FOS - Causes loss of a terrestrial traffic channel to theMSC. The channel will no longer be used for traffic.

Impact BSS O&M; Capabilities

Loss Yes for DSP restart No

Degradation – Yes of OTP restart

5.8.1 Corrective Action

None. This alarm reports an autonomous restart.