9100/f9100 series concealed vertical rod exit device

23
INSTALLATION INSTRUCTIONS 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE I9100-6 8/06 1135-26

Upload: others

Post on 01-Feb-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

INSTALLATION INSTRUCTIONS

9100/F9100 SERIESCONCEALED VERTICAL ROD EXIT DEVICE

I9100-6 8/061135-26

Page 2: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

2

RHR LHR

LHRRHR RHR LHRRHR LHR

HANDING

TYPICAL INSTALLATIONS

SCREW CHART

9100SeriesDevice

9300SeriesDevice

9100SeriesDevice

9500SeriesDevice

9100SeriesDevice

9100SeriesDevice

9100SeriesDevice

R.H.P.T.S.

R.H.P.M.S.

R.H.P.M.S.

F.H.P.M.S.

O.H.P.M.S.

F.H.P.U.C.M.S.

F.H.P.T.S.

All Screws Are Phillips Head

Round Head Phillips Machine Screw x Thru Bolt

Flat Head Phillips Undercut Machine Screw

Round Head Phillips Tapping Screw

Round Head Phillips Machine Screw

Flat Head Phillips Machine Screw

Oval Head Phillips Machine Screw

Flat Head Phillips Tapping Screw

Page 3: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

ba c

c2c1

b1

3

1

40 5/16"(1024 mm)

2 3/4" (70 mm)

2

FINISHED FLOOR OR THRESHOLD

RERERENCEDIMENSION FROM OUTSIDE DOOR EDGE

RERERENCEDIMENSION FROM OUTSIDE DOOR EDGE

2 3/4" (70 mm)

LHRB

2 3/4" (70 mm) From Edge Of Door

4 3/16" (106 mm) MINIMUM STILE

1 1/2" (38 mm) MINIMUM

1 1/2" (38 mm) MINIMUM

CUTOUT

HORIZONTALREF. LINE

VERTICAL REF. LINE

Installation

Door preperation

Read the entire instruction sheet prior to installation.

Before Installing Hardware:

1. Device should be installed and preliminary adjustments made prior to hanging door(s) in frame. (Door typically lying on saw horses at this time).

2. Verify door width, with carton label for correct exit device length.

3. For hand reversal of chassis assembly see Step 3.

4. For hand reversal of trim assembly see Step 4.

Note: If device is to be installed over glass lite panels, shim kit may be required, order No. GK9000.

Note: Device shipped standard for 8' (2438 mm) high door opening. For doors up to but not over 10' (3048 mm) order "ETR" (Extended to rod) device.

Page 4: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

4

g h

k

3

i

j bc

d

f

e

a

4

21/32" (17 mm) min

5/16" (8 mm) - 11/32" (9 mm)

1 1/8" (29 mm) min

RHR LHRNOTE: Spindle mustbe installed with drivepin in vertical positionas shown.

Note: For specific trim functions, cylindertype, and handing information; see additionalinstructions packed with trim.

Standard "K" Trim

Standard "C" Trim

Standard "R" TrimStandard "V" Trim Standard "T" Trim

Standard "Y" Trim

LHRB(Left Hand Reverse Bevel)

NOTE:Longer leg down.

RHRB(Right Hand Reverse Bevel)

If hand reversal of chassis is required follow steps below in alphabetical sequence.

Rotate chassis180 Degrees

Handing of trim, and cylinder specifications and installation.

Page 5: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

6

5

a b

b

a

b

cd

Drill Jig (Supplied)

gCotter pin

Sleeve

Upper Internal Rod

Upper External Rod

Mounting Angles

e

8-32 x 1/4 F.H.P.M.S.

f

e

Adjusting Bolt

1/2

5

Locking Screw

around tube as shown.Bend legs of cotter pin

Optional mounting bracket(Aluminum Door)

"ETR" Top Connecting Rod

9' (2743 mm)

10' (3048 mm)Door

Door

(44-57 mm)1 3/4" - 2 1/4"

(191 mm)7 1/2"

(635-1219 mm)

(38 mm)1 1/2"

25" - 48"

HORIZONTAL REF.

VERTICAL REF.

Top latch mounting bracket and drawbar assembly

Refer to carton label for model and trim number prior to drilling.

Refer to Template T9100, located at rear of instruction bookletfor specific hole locations, drill size and screw sizes.

NOTE: Holes must be parrellon opposite side of door.

Top and bottom rods are shipped standard for 8' (2438 mm)door openings. Top rod is 36 1/2" (927 mm) in length. Bottomrod is 21 1/2" (546 mm) in length. For doors over 8' (2438 mm)but not over 10' (3048 mm) a special "ETR" top connectingrod is used (See Below.)

If cutting is required, deduct required door opening height fromstandard 96" (2438 mm) height, 120" (3048) with "ETR". Cut difference from top rod, do not cut threaded end.

NOTE:Drilling of hole for cotter pin is required for all door openings.

Thread upper external rod all of the way on to adjusting bolt, to ensure that it rotates freely. Add lubricant if neccessary. Then rotate it about half way back down to complete installation.

Slide drill jig (supplied) over rod and drill7/64" (3 mm) DIA. hole thru rod. Removedrill jig and insert sleeve into rod. Usingpreviously drilled hole as guide, drill same size hole through sleeve.

Cotter pin should be inserted thru last hole. If additional length is required during preliminary adjustment, move cotter pin to next hole. This will give an additional 1/2" (13 mm) of length to drawbar assembly.

Page 6: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

8-32 x 1/4 F.H.P.M.S.

Lower External Rod

Sleeve

Cotter ping

e

c

Adjusting Bolt

b

Lower Internal Rod

6

f

e 1/2

Mounting Anglesa

7

Drill Jig (Supplied)d

Optional Pullman Latch

8-32 x 1/4 F.H.P.M.S.

Locking Screw

Bend legs of cotter pinaround tube as shown.

Optional mounting bracket(Aluminum Door)

Thread lower external rod all of the way on to adjusting bolt, to ensure that it rotates freely. Add lubricant if neccessary. Then rotate it about half way back down to complete installation.

Slide drill jig (supplied) over rod and drill7/64" (3 mm) DIA. hole thru rod. Removedrill jig and insert sleeve into rod. Usingpreviously drilled hole as guide, drill same size hole through sleeve.

Cotter pin should be inserted thru last hole. If additional length is required during preliminary adjustment, move cotter pin to next hole. This will give an additional 1/2" (13 mm) of length to drawbar assembly.

Top and bottom rods are shipped standard for 8' (2438 mm)door openings. Top rod is 36 1/2" (927 mm) in length. Bottomrod is 21 1/2" (546 mm) in length.

If cutting is required, deduct required door opening height fromstandard 96" (2438 mm) height. Cut difference from top rod, donot cut threaded end.

Bottom rod should not have to be cut , unless horizontal referenceline is moved down from recommended 40 5/16" (1024 mm) height.

NOTE:Drilling of hole for cotter pin is required for all door openings.

Bottom slide bolt or latch mounting bracketand drawbar assembly

Page 7: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

CLOF LATCH

(NOT DOOR)

1 1/8"(29 mm)

CLOF LATCH

7/16"(11 mm)

TOP VIEW OF DOOR

8

7

Connecting Link Assemblya

Locking Screw

Upper Drawbar Assembly

b

c

Vertical Reference Line

a

b

c

d

d

e

(2) 10-32 x 1/4" (6 mm) F.H.P.M.S.

f

Attach mounting bracket with

Attach Mounting BracketWith (6) 10-32 x 3/8" F.H.P.M.S.Or (6) #10 x 1" (25 mm) F.H.P.T.S.

Connecting Link Arm

Door Cutout (Top & Bottom)

For Wood Doors.(Opptional Aluminum Door Bracket)

(10 mm)(19 mm)3/4" 3/8"

(84 mm)(38 mm)1 1/2" 3 5/16"

(Aluminum Door Only)

DRILL & TAP FOR

TOP & BOTTOM.10-32 (6) PLACES

OF DOOR.FROM INSIDE FACEMAINTAIN DIMENSION

5/16"(8 mm)

2 3/4"(70 mm)

3/4"(19 mm)

7/8"(22 mm)

1 1/2"(38 mm)

1 7/16"(37 mm)

Push up on bottom of drawbar assembly.Top latch should retract and remain retracted,captured by tripping lever.

Proceed to next page.

As connecting link arm nears cutout in face of door,insert finger through cutout and guide connecting link through.

Holding connecting link in full up position, tighten lockingscrew as shown.

Loosen locking screw in upper drawbar assembly as shown. Connecting link arm should move up anddown freely.

With connecting link arm in down position, guide upperdrawbar assembly down through opening in top of door.

Installation of top latch and drawbar assembly

Page 8: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

9

8

Attach mounting bracket with

Locking Screw

Lower Drawbar Assembly

Vertical Reference Line

a

b

(2) 10-32 x 1/4" (6 mm) F.H.P.M.S.With (6) 10-32 x 3/8" F.H.P.M.S.Attach Mounting Bracket

c

c

d

d

c

Connecting Link Assembly

Connecting Link Arm

a

b

For Wood Doors.Or (6) #10 x 1" (25 mm) F.H.P.T.S.

(Optional Aluminum Door Bracket)

As connecting link arm nears cutout in face of door,insert finger through cutout and guide connecting linkthrough.

Holding connecting link in full up position, tighten lockingscrew as shown.

Both connecting links should be in the up right position atthis time, secured by locking screws.

Loosen locking screw in lower drawbar assembly as shown. Connecting link arm should move up anddown freely.

With connecting link arm in down position, guide lowerdrawbar assembly up through opening in bottom of door.

Installation of bottom latch and drawbar assembly

Page 9: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

a1 (Wood)

12-24 x 1 1/4" R.H.P.M.S.

a4 ("Y" Trim)(25 mm)1" DIA.

(10 mm)3/8" DIA.

12-24 Tap

12-24 x 1 1/4" R.H.P.M.S.

3/8" DIA.(10 mm)

12-24 x 1 1/4" R.H.P.M.S.

a2 (Metal)

12-24 x 1 1/4" R.H.P.M.S.

a3 (Thru Bolts)

a5 ( "CV" Trim)

#12 x 1 1/4" R.H.P.T.S.

3/8" DIA.(10 mm)

10

(No Trim) (No Trim) (Wood or Metal)(No Trim)

Bell crank

8-32 x 1/2" P.P.H.M.S.

Connecting Link

Connecting Link

9

1" DIA.(25 mm)

Guide top connecting link through cutout in top chassis assembly. Slide bell crank up if neccessary and guide bottom connecting link through cutout in bottom of chassis. Attach connecting links to bell crank with (2) 8-32 x 1/2" (13 mm) P. P. H. M. S.

Proceed to mount chassis to door using one of the proper methods shown below.

Detailed chassis installation

Chassis installation. If using GK9000 install shims under chassis at this time

Page 10: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

11

Connecting Link

10

Locking Screw

Top Rod Adjusting Screw

Bottom Rod Adjusting Screw

Locking ScrewConnecting Link

Tripping Lever

a

Bell crank

b

(continued on following page)

Bell crank should be all the way down in slot.

Push down on top latch bolt. Boltshould not retract. It should deadlock. If latch bolt moves in, ad-ditional adjustment will be requried.

Depress tripping lever allowinglatch bolt to extend.

Preliminary rod adjustment (door still on saw horses)

Page 11: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

12

11

a

b

c

c

d

If latch bolt was able to be depressed,top rod is too long and will have to be adjusted. Follow steps below.

Rotate adjusting screw clockwise (right)to shorten rod assembly. Medium flat bladescrewdriver required.

Recheck adjustment after each half turn onadjusting screw. Do this by attempting to pushin on top latch bolt and then pushing in on trip-ping lever to release bolt. Adjust only until deadlatching of top latch bolt is achieved. (Latch boltwill not retract when pushed.)

Tighten locking screw when complete.

NOTE:Check outside trim operation and maked adjustmentsin the same manner as before, except use outside trimfunction instead of touch bar assembly to retract thelatchbolts.

Loosen locking screw intop connecting link. No. 2phillips head screwdriverrequired.

Preliminary rod adjustment (continued): If latch bolt dead latched proceed to next page.NOTE: If outside trim is being used adjust rod to function properly with it.

Page 12: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

"L" = "X" - 2 1/2" (64 mm)

b

a

13

"L"

12

c

1 13/16" (46 mm)

"X"

"L"

14

a2

a18-32 x 3/8" P.H.P.M.S.

8-32 x 3/8" P.H.P.M.S.

Cutting touch bar to length

Installation of touch bar to chassis

NOTE:Chassis screws areshipped in chassisassembly.

NOTE:For optional "Filler" installationssee "Options" pages at rear.

NOTE: Use caution when cuttingtouchbar to size on units with "ES","MS", "BPA", "BPAR", "LM", "MD" ,"DE" or "DWA" options."DO NOT CUT WIRES."

SIZE A:Will fit 48" (1219 mm) door opening without cutting.Can be cut to fit a 34" (864 mm) minimum door opening.SIZE B:Will fit 36" (914 mm) door opening without cutting.Can be cut to fit a 28" (711 mm) minimum door opening.SIZE C:Will fit 30" (762 mm) door opening without cutting.Can be cut to fit a 25" (635 mm) minimum door opening.

IMPORTANT

Page 13: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

LC

CL

15

13

b1a

a

*

b

c

*

c

16

3/4" (19 mm)

439 Strike

17

Standard installation of end cap mounting bracket

5/16" DIA. (8 mm)

3/8" (10 mm) Dia. (Thru bolts)No. 14 Drill - 12-24 Tap (Metal)

ES (Electric Latch Retraction)ADDITIONAL HOLE REQUIRED:

See "OPTIONS" pages

1/8" (3 mm) Drill 1" (25 mm) Deep (Wood)

DWA (Direct Wired Alarm)

for additional information.

LM (Latch Monitor)MS (Micro Switch)

OPTIONAL INSTALLATIONS

Hang door in frame

0F LATCH

FINISHED FLOOR

DRILL 13/16" DIA. HOLE 1" DEEP

OF STRIKE

1" INSIDE FACE OF DOOR

MD (Magnetic Dogging)

1/4" REF.(6 mm)

(25 mm)(21 mm)

(25 mm)

Standard 439 strike installation: Optional bottom strikes on following page

Page 14: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

2"

1"

2"

1"

LC

18

14

340 Strike

19

3/8" (10 mm)

1 1/2" (38 mm)

431 Strike

1 1/2" (38 mm)

1 3/8" (35 mm)

5/16" (8 mm)

Optional pullman latch No. 431 strike installation

STEEL ANCHORS

1/4"-20 x 1" R.H.P.M.S.

FINISHED FLOOR

INSIDE FACE OF DOOR

OF STRIKE

NOTE: DRILL 5/8" (16 mm)

(13 mm) DEEP MINIMUM.DIA. HOLE 1/2"

& 12 X 1" F.H.P.T.S.

FOR SURFACE STRIKEDRILL (2) 5/16" (8 mm) DIA. HOLES X 1" (25 mm)DEEP FOR LEAD ANCHORS

Optional slide bolt No. 340 strike installation

(51 mm)

(25 mm)1/4" REF.(6 mm)

(22 mm)7/8"

(51 mm)

(25 mm)

3/8" Dia. (10 mm) holex 2" (51 mm) Deep(2) Places

NOTE: 1 5/16" (33 mm) Min. to 1 5/8" (41 mm) Max. Square cut out for recessed strike, 1" (25 mm) Deep.

Page 15: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

15/16"

1/8" (3 mm)

1 13/16"

9/16"

13/16"3/4" 1 1/2"

2"

1/2"

13/16"

1 3/16"

1 1/2"

19/32"

1 5/8"

13/16"

3/4"

1 5/8"2"

1 5/8"

3/4"13/16"

1 1/2"

2"15/16"

13/16"

2 3/4"

LC

CL

LCLC

LC

CL

CL

20

15

21

Standard No. 418 top strike installation

Optional prep for No. 419 top strike in wood frame

EDGE OF STOP

OF STRIKE

DOORSTOP

REINFORCEMENT

9100F9100

OF STRIKE

CUTOUT IN STOP.

NOTE: 1/2" x 2" x 1/16"

EDGE OF STOP

NO. 419

OF STRIKE

TOP EDGE OF STOP

STOPDOOR

WOOD JAMB

OF STRIKECUT OUT DIMENSIONS

REINFORCEMENT

MOUNTED STRIKE

OF STRIKE

NO. 418

#10-32 TAP (2 PLACES)FOR 10-32 x 3/8" F.H.P.U.C.M.S.

(24 mm)

(13 mm x 51 mm x 2 mm)

(24 mm)

(19 mm)

(46 mm)

(14 mm)

(21 mm)

(51 mm)

(38 mm)

15/16"

(13 mm)

(21 mm)

(30 mm)

(51 mm)

(38 mm)

(15 mm)

(21 mm)

(41 mm)

(19 mm)

(41 mm)

(19 mm)

(41 mm)

(21 mm)

(51 mm)

(38 mm)

(24 mm)

(21 mm)

(70 mm)

Page 16: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

22

16

aDepress and release touch bar

If instructions were followed during thepreliminary adjustment steps, the top latchshould remain retracted. You may onlyhave to adjust the bottom latch.

Top latch must go fully inand remain in the retractedposition, held by the trip-ping lever.

Bell crank should be infull up position.

Bottom slide bolt or pullman latchshould be flush across bottom ofdoor and bracket.

Final adjustments of device and rod assemblies

Door to be blocked open to check adjustments.

Page 17: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

23

17

Locking screw

Adjusting screwTo adjust bottom slide bolt orlatch follow steps below.

Top latch should be in the capturedor retracted position.

Loosen locking screw on bottomconnecting link assembly.

Rotate adjusting screw clockwise (right)to shorten and counter-clockwise (left) tolengthen.With top latch retracted, adjust bottom roduntil slide bolt or latch is flush across thebottom of the door.

Re-tighten the locking screw.

Re-check outside trim operation.

Top latch and rod assembly MUST always beadjusted first. If latch remained retracted anddead latches when tripping lever is tripped, youmay proceed to adjust the bottom latch if re-quired.

Final adjustments continued

Door to be blocked open to check adjustments.

Page 18: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

24

18

Depress tripping lever allowing latch bolts to extend.

Check to see that top latch is dead latched, bottom bolt or latch extended (Note: If pullman latch is usedin place of slide bolt on bottom, it too will dead latchwhen fully extended and adjusted properly.) and seethat bell crank is completely down.

Depress touch bar slowly. Check to see that bell crankis all the way up and latches are fully retracted and re-main retracted, held by tripping lever when touch bar is released.

If outside trim is installed, its function must be checkedat this time as well. Additional adjustment to rods maybe required for proper function of outside trim .

Rotate knob, lever or depress thumb piece. Bell crankshould travel upward retracting latches. Latches shouldbe captured by tripping lever when outside trim is re-leased. And dead latch when tripping lever is tripped andlatches are extended. If latches do not remain retractedor if top latch does not dead latch when extended, youwill have to re adjust the top rod assembly.

If latch does not dead latch, turn adjusting screw one (1)turn to the right (clockwise) and re-check. Check for deadlatch after each turn on adjusting screw.

If latch does not retract fully or is not captured by thetripping lever, turn adjusting screw one (1) turn to the left (counter-clockwise). Re-check after each turn bydepressing tripping lever and then operating outside trim.

NOTE: Bell crank may not sit in full up position whenlatches are held retracted after adjustments have been made for outside trim operation.

Once outside trim and inside exit operation are achievedrecheck bottom bolt or latch. Re-adjust if neccessary.

Close door and check for proper alignment of strikes andalignment of tripping lever with top stop.

Check entrance and exit operation of door and hardware.

Final adjustment continued

Page 19: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

25

b 8-32 x 1/4" F.H.P.U.C.M.S.

8-32 x 1/4" F.H.P.U.C.M.S.a

26

a

bc

19

ExtendedRetracted

Standard hex key dogging

NOTE:If carton label lists: "ES", "BPA", "BPAR","DWA", "CD", "MS", "LM", "MD", "DE" or "LM/MS-BP" prefix, see "Options" pagesat rear, prior to installing the end cap.

Installation of covers

GENERAL MAINTENANCE NOTES: The DORMA 9000 Series Exit Devices are designed to give years of trouble free service, however, depending on the installation, location, climate conditions etc. routine maintenance is recommended in all latch bolt locations. The device should be periodically cleaned and re lubricated to ensure proper function and operation of all moving parts.

Page 20: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

a

b3

*b1

*b2

c

*

a2

a1

c1c2

b

12-24 x 3/4" R.H.P.M.S.

8-32 x 1/4" F.H.P.U.C.M.S.

20

23/32" Min(18 mm)

Note: Cylinder not supplied.

5/16" - 11/32"(8 mm) - (9 mm)

1" (25 mm) Min.

1 1/8" (29 mm) Max.to

"CD" (CYLINDER DOGGING) OPTION: "LM" (LATCH MONITOR) OPTION:

"BPA" & "BPAR" (ALARM) OPTION:(STANDARD INSTALLATION)

OPTIONS

BlackCommon

SIZE A:Will fit 48" (1219 mm) door opening without cutting.Can be cut to fit a 39" (991 mm) minimum door opening.SIZE B:Will fit 36" (914 mm) door opening without cutting.Can be cut to fit a 33" (838 mm) minimum door opening.SIZE C:Will fit 36" (914 mm) door opening without cutting.Can be cut to fit a 30" (762 mm) minimum door opening.

To replace batteryremove endcap.

See additional sheetIAL9000, packed withdevice for alarmed exitdevice operation.

NOTE: Touch bar mustbe in dogged down po-sition, to remove the rear filler panel.

NOTE: Touch bar mustbe in dogged down po-sition, to remove the rear filler panel.

(Standard mortisecylinder supplied.)

To install customersupplied cylinder, seecylinder dogging optionat top of page.

*NOTE: Use caution when cutting touch bar and rail tolength.

BPA: Battery powered alarm, sounds continuous or until disarmed.

BPAR: Battery powered alarm, soundsfor 4 minutes, automatically resets.

"Alarm mode set at factory."

RedNormally Closed

GreenNormally Open

SPDT, .5 amp@ 28VDC max.

*NOTE: Use caution when cutting touch bar and rail tolength.

Latch monitor: Monitors movement oflatch bolt, with or without depressingof touch bar.Can be wired normally open or normallyclosed.

Useable Cams

Cylinder dogging installation instructions & cylinder speci-fications. (Requires astandard mortise cylinder.)

001Std. (Yale)C136A0212667-3SC1SC1 4200-82-2002 Std.13-0664 or 13-06600012160

ArrowAssaBestCorbin/RusswinFalconIlco/UnicanLoriSargentSchlageYale

Page 21: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

c2

d

b2 e

c1b1

af

*

12-24 x 3/4" R.H.P.M.S.

8-32 x 1/4" F.H.P.U.C.M.S.

c

b

a

d e

21

"ES" (ELECTRIC LATCH RETRACTION) OPTION:

"MS" (MICRO SWITCH) OPTION:

"DWA" (DIRECT WIRED ALARM) OPTION:

OPTIONS

(Non-polarized)

GreenWhite

Black Red

18 GA. Wire Minimum

*NOTE: Use caution when cutting touch bar and rail tolength.

Electrically retracts latchbolt(s) when energized by power supply.

REQUIRES DORMA PS-501 POWER SUPPLY, WILL NOT OPERATE FROM OTHER MANUFACTURES POWER SUPPLIES.

PS-501 Will operate (2) "ES" 9100 exitdevices. By adding a second "ES2" logic card, (2) additional "ES" 9100 exit devices may be

used.

NOTE: Touch bar mustbe in dogged down po-sition, to remove the rear filler panel.

DWABattery Eliminator

See additional sheetIAL9000 packed with device for alarmed exitdevice operation.

(Standard mortisecylinder supplied.)

Connected to outside power source.12-24 Volt AC/DC Power Supply.i.e. DORMA Step down transformer,Contact DORMA for other powersupplies available.

*NOTE: Use caution when cutting touch bar and rail tolength.

SPDT, .5 amp@ 28VDC max.

GreenNormally Open

BlackCommon

RedNormally Closed

*NOTE: Use caution when cutting touch bar and rail tolength.

"MS" option allows monitoring of touch bar during normal operation, or can be used as a signal switch for horn, light etc. Come standard with(2) two micro switches. Both can be wired either Normally Open or Normally Closed. Can be added to device after installation.

Page 22: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

22

"MD" (MAGNETIC DOGGING) OPTION:

"DE" (DELAYED EGRESS) OPTION:

BlackRed

OPTIONS

NegativePositive

+-

* For wiring to electric hinge or power transfer.

DE9100

SOUN

DS. D

OOR CA

N BE

OPENED IN

15 SEC

ONDS.

PUSH UNTIL ALARM

SIZE A:Will fit 48" (1219 mm) door opening without cutting.Can be cut to fit a 40 1/2" (1029 mm) minimum door opening.SIZE B:Will fit 36" (914 mm) door opening without cutting.Can be cut to fit a 34 1/2" (876 mm) minimum door opening.

REQUIRES DORMA PS-510 POWER SUPPLY.

Easily accessible slide in and out electronics.Meets UL & ANSI/BHMA requirements.

85 decibel Alarm - Standard

LED Status Indicator - Standard

Nuisance Alarm - Standard

Key Switch Control - Standard

Remote Authorized Egress - Standard

Remote Re-arm - Standard

Remote Bypass - Standard

Door Position Input - Standard

Note: Refer to 9000 Series Installation Instructions for templating and installation of device. These are additional instructions for installation and operation of the "Delayed Egress" unit.

WIRE 18AWG 16AWG 14AWG 12AWGFEET 25 50 75 100

Maximum Wire Length From Power Supply To Device In Feet x Wire Gage/Size *

.25 AMP CURRENT DRAW @ 24VDC

REQUIRES DORMA PS-545 POWER SUPPLYCAPABLE OF POWERING 1 - 4 "MD" DEVICES.THE USE OF A POWER TRANSFER (ie ES105) OR AN ELECTRIC HINGE IS RECOMMENDED.

FITS "STANDARD" TOUCH BAR AND RAIL ASSEMBLIES ON BOTH THE 5000 AND9000 SERIES EXIT DEVICES. NOT AVAILABLE ON DEVICES SUCH AS "ES", "DE", "AL" ETC.

MAXIMUM HOLDING FORCE 40# - 60#.IMMEDIATE RELEASE UPON REMOVAL OF POWER.

*NOTE: Use caution when cutting touch bar and rail tolength.

Electrically dogs touch bar when energized by power supply, then depressed. Releases upon interuption of power.

Page 23: 9100/F9100 SERIES CONCEALED VERTICAL ROD EXIT DEVICE

TYP

13 17/32"

TYP

3 3/4" TYP

7/32"

1 3/8"

3/4"

2 3/16" TYP

E

C

VE

RT IC

AL R

EF. L IN

E B

AS

ED

ON

2 3/4" FRO

M O

UT S

IDE

DO

OR

ED

GE

40 5/16" FROM

HORIZONTAL

FINISHED FLOOR

REFERENCE

FOR

WO

OD

DO

OR

8 1/8" x 2 3/8" x 3/4" DE

EP

MIN

.

DDD

JK

5/16" (8mm) DIA. THRU DOOR - C08, R08 & K082 1/8" (54mm) DIA. THRU DOOR - C08, R08 & K08

HF

C

F

C

E

G

C 3/8" (10 mm) DIA. THRU

3/8" (10 mm) DIA. THRU

SIDE FACE ONLY FOR "O5" & "22" FUNCTION

3/8" (10 mm) DIA. THRU

1" (25.4 mm) DIA. THRU FOR "08" FUNCTION

2 1/4" (57 mm) x 8" (203 mm) CUTOUT OUT-

1 1/4" (32 mm) DIA. THRU FOR "03" FUNCTION

1 3/8" (35 mm) DIA. THRU FOR "03" FUNCTION

2" (51 mm) DIA. OUTSIDE FACE "08" FUNCTION

D 3/8" (10 mm) DIA. THRU

B

JK

NO. 14 DRILL 12-24 TAP

5/16" (8mm) DIA. THRU DOOR - C08, R08 & K082 1/8" (54mm) DIA. THRU DOOR - C08, R08 & K08

EF

C

F

C

E

C

AB

1/8" (3 mm) DIA. DRILL 1" (25 mm) DEEP

1" (25.4 mm) DIA. THRU FOR "08" FUNCTION

3/8" (10 mm) DIA. THRUNO. 14 DRILL 12-24 TAP

3/8" (10 mm) DIA. THRU

3/8" (10 mm) DIA. THRU

1 1/4" (32 mm) DIA. THRU FOR "03" FUNCTION

1 3/8" (35 mm) DIA. THRU FOR "03" FUNCTION1" (25.4 mm) DIA. THRU FOR "05" FUNCTION

D

T9100 WEB 8/06

J

J

K

J

K

J

H

FF

E

Cut out top and bottom1" (25 mm) Wide x 1 5/8" (41 mm) High

INSIDE DOOR PREP

OUTSIDE DOOR PREP

G

B

CA

D

B

CA

DRILL CHART

B

CAC

B

A

C

C

C

E

3/8" (10 mm) DIA. THRU

DRILL CHART

DO NOT SCALEDRAWING