90 % cd - f.t. james...aeed, advanced energy engineering & design, inc chattanooga, tn 37405...
TRANSCRIPT
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
71
4 ch
erry stre
et, ch
atta
no
og
a, te
nn
esse
e 3
74
02
p.4
23
6
34
0
80
6 f.4
23
7
52
8
49
9 w
ww
.rive
r-st-a
rch
ite
ctu
re
.co
m
Release Date:
Project No.:
3/3
1/2
01
5 1
0:1
7:2
4 A
M
12055 G
AT
EW
AY
W
ES
T B
LV
D, E
L P
AS
O , T
X
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZA
RA
GO
ZA
H
OT
EL P
AR
TN
ER
S, LLC
FIRE PROTECTION
FP0.1
COVER SHEET
FIRE PROTECTION GENERAL NOTES
ABBREVIATIONS
AFC - ABOVE FINISHED CEILING
AFF - ABOVE FINISHED FLOOR
AFG - ABOVE FINISHED GRADE
ALV - ALARM VALVE
BMS - BUILDING MANAGEMENT SYSTEM
Cr - CROSS
DPV - DRY PIPE VALVE
E - 90 DEGREE ELBOW
FACP- FIRE ALARM CONTROL PANEL
FBO - FURNISHED BY OTHERS
FP - FIRE PUMP
GV - GATE VALVE
JP - JOCKEY PUMP
NTS - NOT TO SCALE
FA - FIRE ALARM
EE - 45 DEGREE ELBOW
BFP - BACK FLOW PREVENTER
BFG - BELOW FINISH GRADE
AHJ - AUTHORITY HAVING JURISDICTION
BV - BUTTERFLY (wafer) CHECK VALVE
CV - SWING CHECK VALVE
DeL V - DELUGE VALVE
(E) - EXISTING
FS - FLOW SWITCH
GC - GENERAL CONTRACTOR
NIC - NOT IN CONTRACT
IAW - IN ACCORDANCE WITH
PAV - PREACTION VALVE
PIV - POST INDICATOR VALVE
FLEXIBLE CONNECTION
SYMBOLS
RECESSED PENDANT SPRINKLER (RESIDENTIAL TYPE)
Lt.E - LONG TURN ELBOW
PA - PUBLIC ADDRESS
OS&Y - OUTSIDE SCREW & YOKE
OC - ON CENTER
St - STRAINER
T- TEE-FLOW TURNED 90 DEGREES
TS - TAMPER SWITCH
UG - UNDERGROUND
UNO - UNLESS NOTED OTHERWISE
WCV - BUTTERFLY (wafer) CHECK VALVE
HORIZONTAL SIDEWALL SPRINKLER
FIRE PROTECTION LEGEND
UPRIGHT SPRINKLER
1. SCOPE OF WORK
A. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIALS, AND LABOR REQUIRED TO SATISFY A COMPLETE WORKING SYSTEM
WHETHER SPECIFIED OR IMPLIED.
B. THE WORK IS TO BE PERFORMED IN STRICT COMPLIANCE WITH NFPA 13 (2002 EDITION), ALL CODES AND OTHER NFPA REGULATIONS
GOVERNING WORK OF THIS NATURE.
C. THE CONTRACTOR SHALL EXAMINE THE PROPOSED SITE AND SHALL DETERMINE FOR HIMSELF THE CONDITIONS THAT MAY EFFECT THE
WORK BEFORE SUBMITTING ANY PROPOSAL. NO ALLOWANCE SHALL BE MADE IF THE CONTRACTOR FAILS TO MAKE SUCH
EXAMINATIONS.
D. ALL EQUIPMENT AND MATERIALS SHALL BE AS SPECIFIED OR AN "APPROVED EQUAL" BY THE ENGINEER OR ARCHITECT.
2. PERMITS
A. THE CONTRACTOR SHALL SECURE ALL PERMITS OR APPLICATIONS AND PAY ANY AND ALL FEES.
B. THE CONTRACTOR SHALL BE A LICENSED FIRE SPRINKLER CONTRACTOR.
3. SHOP DRAWINGS
A. SUBMIT A MATERIAL LIST AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE ARCHITECT/ENGINEER AND STATE FIRE MARSHALL
FOR APPROVAL. THE CONTRACTOR SHALL SUBMIT SIX SETS OF SHOP DRAWINGS AND THEY SHALL BE CLEARLY LABELED.
4. SPRINKLER HEADS
A. WHERE SPRINKLER HEADS ARE INSTALLED IN ACOUSTICAL CEILING TILES, HEADS SHALL BE CENTERED IN THE TILE.
B. SPRINKLER HEADS ARE TO BE PROVIDED IN THE STYLE AND COLOR/FINISH AS SPECIFIED ON THE DRAWING. HOWEVER, CONTRACTOR
TO CONFIRM WITH OWNER/ARCHITECT PRIOR TO PURCHASE THAT THE SPECIFIED COLOR/FINISH IS ACCEPTABLE.
5. SPRINKLER PIPING
A. PIPE SHALL BE MADE TO ANY OF THE SPECIFICATIONS LISTED. WELDING WILL NOT BE PERMITTED IF THERE ARE ANY SPRINKLERS
CONNECTED THERETO.
ASTM A53
ASTM A120
ASTM A135
B. PIPING MATERIAL MAY BE SCHEDULE 10 (THINWALL) PROVIDED JOINTS ARE MADE BY ROLL-GROOVE COUPLING. THREADING WILL NOT
BE PERMITTED ON SCHEDULE 10 (THINWALL).
C. PIPING MATERIAL MAY BE SCHEDULE 40 WITH FLANGED, ROLL-GROOVED COUPLINGS, OR THREADED JOINTS.
D. DRY SPRINKLER PIPING SHALL BE SLOPED TO DRAIN. LOW POINT DRAINS SHALL BE PROVIDED AT ANY CHANGE IN PITCH.
6. PIPE SUPPORTS
A. ALL HANGERS MUST BE AN NFPA 13 APPROVED TYPE. NO SPRINKLER PIPING IS TO BE SUPPORTED FROM ANY MECHANICAL OR
ELECTRICAL DEVICES.
B. ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE IN A NEAT AND WORKMANLIKE MANNER. VERTICAL RISERS SHALL BE
SUPPORTED AT EACH FLOOR LEVEL WITH STEEL PIPE CLAMPS. THE USE OF WIRE OR STRAP METAL HANGERS TO SUPPORT PIPES WILL
NOT BE PERMITTED. HANGING PIPES FROM OTHER PIPES WILL NOT BE PERMITTED. PIPING SHALL BE CAREFULLY COORDINATED
BEFORE INSTALLATION WITH OTHER SYSTEMS AND EQUIPMENT IN CHASES AND OTHER CONGESTED AREAS.
C. SEISMIC PERFORMANCE: FIRE-SUPPRESSION PIPING BRACING SHALL BE IN ACCORDANCE TO NFPA 13.
7. WORKING PLANS
A. THE DRAWINGS INCLUDED AS PART OF THIS SET OF CONSTRUCTION DOCUMENTS ARE TO PROVIDE ENGINEERING DESIGN INTENT.
THE CONTRACTOR SHALL PREPARE WORKING DRAWINGS (AS DEFINED BE NFPA 13) WHICH SHALL INCLUDE HYDRAULIC CALCULATIONS
AND WILL BE SUBMITTED TO THE ENGINEER AND FIRE MARSHALL FOR APPROVAL.
8. TESTS
A. ACCEPTANCE AND HYDROSTATIC TESTS TO BE PERFORMED IN ACCORDANCE WITH CHAPTER 10 OF NFPA 13.
9. MISCELLANEOUS
A. DO NOT SCALE THIS DRAWING FOR EXACT DIMENSIONS. VERIFY ALL FIGURES, CONDITIONS, AND DIMENSIONS AT THE JOB SITE.
B. THE SPRINKLER PLANS ARE INTENDED TO BE DIAGRAMATIC. THEY ARE NOT INTENDED TO SHOW EVERY ITEM IN ITS EXACT LOCATION.
10. GUARANTEE
A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR PERIOD OF ONE(1) YEAR FROM DATE OF ACCEPTANCE.
DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THE SPRINKLER CONTRACTOR'S EXPENSE.
HAZARD CLASSIFICATIONS
A. OFFICES AND CONFERENCE AREAS: LIGHT HAZARD
B. GUEST ROOMS: LIGHT HAZARD
C. MECHANICAL EQUIPMENT ROOMS: ORDINARY HAZARD, GROUP 2
D. LAUNDRY ROOM: ORDINARY HAZARD, GROUP 1
E. PORTE COCHERE ORDINARY HAZARD, GROUP 1
F. ELECTRICAL ROOM: ORDINARY HAZARD, GROUP 1
FLOW TEST DATA
DATA PROVIDE BY: EL PASO FIRE DEPARTMENT
DATE: 12-30-2014
TEST PERFORMED BY: CHRISTOPHER TIJERINA
TEST HYDRANT: 10835
STATIC PRESSURE: 145 PSI
RESIDUAL PRESSURE: 143 PSI
FLOW: 787 GPM
REQUIRED CONDITIONS:
DESIGN AREA #1: 70 PSI @ 641 GPM (W/ 250 GPM HOSE ALLOWANCE)
DESIGN AREA #2: 50 PSI @ 148 GPM (W/ 100 GPM HOSE ALLOWANCE)
DESIGN AREA #3: 50 PSI @ 176 GPM (W/ 100 GPM HOSE ALLOWANCE)
SAFETY FACTOR: 109% (MINIMUM 10% REQUIRED)
ADEQUATE WATER SERVICE AVAILABLE: YES
DRY SYSTEM VOLUME: 73 GALLONS
FLOW SWITCH
FLOOR CONTROL VALVEPENDANT SPRINKLER
UPRIGHT SPRINKLER
STANDPIPE
DDCA - DOUBLE DETECTOR CHECK VALVE ASSEMBLY
FDC - FIRE DEPARTMENT CONNECTION
RECESSED PENDANT SPRINKLER (COMMERCIAL TYPE)
FP0.1 FIRE PROTECTION - COVER SHEET
FP1.2 FIRE PROTECTION - 2ND FLOOR PLAN
04/27/15
P
R
O
G
R
E
S
S
S
E
T
x
FIRE PROTECTION SHEET INDEX
TITLE#
DATE
FP1.1 FIRE PROTECTION - 1ST FLOOR PLAN
FP1.3 FIRE PROTECTION - 3RD FLOOR PLAN
FP1.4 FIRE PROTECTION - 4TH FLOOR PLAN
FIRE PROTECTION - DETAILSFP2.1
ISSUE LOG
x
x
x
x
x
9
0
%
C
D
x
x
x
x
x
x
05/20/15
x
x
x
x
x
x
1
0
0
%
R
E
V
I
E
W
S
E
T
06/25/15
S
S
S
S S
S
S
SS
GYP-1
GYP-1
GYP-1
ACT-1
GYP-1
ACT-3
GYP-1
GYP-1
GYP-1
ACT-1
ACT-1
ACT-1
ACT-3
ACT-3
LAUNDRY
150
BREAK ROOM
143
MEN
141
WOMEN
140
CORRIDOR
144
CORRIDOR
1000
LINEN
149
WORK ROOM
153
ACT-1
ACT-3
OFFICE
148
ENGINEER
145
KING
133
KING
131
QQ - HEARING
129
KING
128
KING
130
KITCHEN
166
S BAR
165
LOBBY
163
MEETING ROOM
167
RECEPTION
162
MARKET
VESTIBULE
160
PBX
152
SWITCH GEAR
151
KING - HEARING
107
ACC. QQ -
SHOWER
105
103
KING
101
102
ACC. KING -
SHOWER
104
CT-2HR
WATER /
MECHANICAL
146
L54
L54L54
L54
L54
L54
L54
L54L54
L54 L54
L54 L54
L54L54
L54 L54
L54 L54
L54 L54
L31
L57
L57 L57
L10 L10 L10
L10 L10 L10 L10
L10L10L10L10
L10 L10
L10
L29
L10
L10
L10 L10
L31
L31
L31
L31
L22
L22
L22
L22
L22
L22L22
L22
L57
L57
L60 L60
L60
L57
D04
L60
L60
L54
L54
L54
L54
L54
L54
L57
L57L57 L57 L57L57L57
L60 L60 L60
L60L60
D04 D04
L60
L33
L33
L33L33L33
L33L33L33
L33
L33
L33 L33
L33
L29 L29
L29L29
L33
L33
L31
L29
L22
L22
L33L33L33L33
L33 L33
L33L33
L31L31
L33 L33
ACT-1
ACT-1
ACT-1
ACT-1
GYP-1
GYP-1
GYP-1
D93
GYP-EX
GYP-EX
GYP-EX
GYP-1
GYP-1
GYP-1
ACT-1
L33
L33
A0.7
GYP-EX
GYP-EX
GYP-EX
GYP-EX
GYP-EX
GYP-EX
GYP-EX
GYP-EX
GYP-EX
GYP-EX
409
GYP-1
ACT-1
ACT-1
ACT-1
400
408
400
400
409
L57
L31
L31
GYP-1
L57
GYP-1
D93
FIRE MAIN ENTERS BUILDING
SEE SHEET FP2.1 FOR RISER DETAIL
ELECTRONIC ALARM BELL
4" CLASS 1
COMBINATION RISER
4" CLASS 1 MANUAL WET
STANDPIPE
DRY PENDANTS FOR WALK-IN
COOLER AND FREEZER
FIRE MAIN (SEE CIVIL FOR CONTINUATION AND
LOCATION OF DDCA, PIV, AND FDC.)
SLEEVE PIPE WALL-PENETRATION WATERTIGHT
DESIGN AREA 1
SLEEVE PIPE WALL-PENETRATION
WATERTIGHT
DESIGN AREA 4
FP1.1
1
SCALE: 1/8"= 1'-0"
FIRE PROTECTION - SPRINKLER - 1ST FLOOR
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
71
4 ch
erry stre
et, ch
atta
no
og
a, te
nn
esse
e 3
74
02
p.4
23
6
34
0
80
6 f.4
23
7
52
8
49
9 w
ww
.rive
r-st-a
rch
ite
ctu
re
.co
m
Release Date:
Project No.:
3/3
1/2
01
5 1
0:1
7:2
4 A
M
12055 G
AT
EW
AY
W
ES
T B
LV
D, E
L P
AS
O , T
X
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZA
RA
GO
ZA
H
OT
EL P
AR
TN
ER
S, LLC
FIRE PROTECTION
FP1.1
SPRINKLER
1ST FLOOR
FIRE PROTECTION PLAN NOTES
1. ALL TAMPER AND FLOW SWITCHES MUST BE CONNECTED TO A MONITORED FIRE
ALARM SYSTEM.
2. FIRE PROTECTION CONTRACTOR TO OBTAIN OWNER/ARCHITECT APPROVAL OF
SPRINKLER TYPE AND FINISH PRIOR TO PURCHASING.
3. FIRE PROTECTION CONTRACTOR TO PROVIDE COVERAGE AS INDICATED ON
DRAWING.
4. SEE ARCHITECTURAL DRAWINGS FOR SMOKE AND FIRE RATED WALLS.
5. SPRINKLER SYSTEMS SHALL BE EQUIPPED WITH FLOOR CONTROL VALVE
ASSEMBLIES ( SEE SHEET FP2.1 FOR DETAIL) AT ALL CONNECTIONS TO RISERS.
SPRINKLER HEAD SCHEDULE (FOR THIS SHEET)
SYMBOL
QTY
MFG. SIN TYPE RESPONSE TEMPERATURE K-FACTOR DESCRIPTION
39 VICTAULIC V2740 PENDANT
QUICK
155 °F 4.9
WHITE, SEMI-RECESSED PENDANT SPRINKLER (RESIDENTIAL TYPE)
130 VICTAULIC V2707 PENDANT
QUICK
155 °F 5.6
WHITE, SEMI-RECESSED PENDANT SPRINKLER (COMMERCIAL TYPE)
22 VICTAULIC V3608 PENDANT
QUICK
175 °F 8.0
BRASS, DRY PENDANT SPRINKLER
1 VICTAULIC V2707 PENDANT
QUICK
155 °F 5.6
BRASS, LAUNDRY CHUTE PENDANT SPRINKLER
8 VICTAULIC V2703 UPRIGHT
QUICK
155 °F 5.6
BRASS, UPRIGHT SPRINKLER
4 VICTAULIC V3410 SIDEWALL
QUICK
155 °F 8.0
WHITE, SIDEWALL SPRINKLER
KING
201
203
205
KING
207
KING
209
KING
211
KING
213
KING
215
217
219
KING
221
KING
223
KING
225
227
229
KING
231
KING
233
KING
230
KING
228
226
KING
224
KING
222
220
218
ACC. QQ INLINE
SUITE
216
KING
210
KING
208
KING
206
ACC. KING
204
202
KING
214
ELECTRICAL
2005
LINEN
2004
COMPUTER/
COMM ROOM
GYP-1
ACT-1
ICE
D04
L60L60
L60
L57
L60 L60
L57
L60 L60
D04
L57
L60 L60
L60L60
D04
L57
L60 L60
L60 L60
D04
L60 L60
L60
L57
L60
L54
L54
L54
L54
L54
L54
L57
L60L60
L60 L60
D04
GYP-1
L60 L60
L57
L60 L60
D04
L60
L57
L60 L60
L60
D04
L60
L57
L57
L57
L29 L29
L33
L33 L33
L33
L31
L31
ACT-1ACT-1ACT-1ACT-1
GYP-1
GYP-1
ACT-1ACT-1ACT-1ACT-1ACT-1ACT-1ACT-1ACT-1ACT-1 ACT-1 ACT-1
4" CLASS 1 MANUAL WET
STANDPIPE
4" CLASS 1
COMBINATION RISER
FP1.2
1
SCALE: 1/8"= 1'-0"
FIRE PROTECTION - SPRINKLER - 2ND FLOOR
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
71
4 ch
erry stre
et, ch
atta
no
og
a, te
nn
esse
e 3
74
02
p.4
23
6
34
0
80
6 f.4
23
7
52
8
49
9 w
ww
.rive
r-st-a
rch
ite
ctu
re
.co
m
Release Date:
Project No.:
3/3
1/2
01
5 1
0:1
7:2
4 A
M
12055 G
AT
EW
AY
W
ES
T B
LV
D, E
L P
AS
O , T
X
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZA
RA
GO
ZA
H
OT
EL P
AR
TN
ER
S, LLC
FIRE PROTECTION
FP1.2
SPRINKLER
2ND FLOOR
FIRE PROTECTION PLAN NOTES
1. ALL TAMPER AND FLOW SWITCHES MUST BE CONNECTED TO A MONITORED FIRE
ALARM SYSTEM.
2. FIRE PROTECTION CONTRACTOR TO OBTAIN OWNER/ARCHITECT APPROVAL OF
SPRINKLER TYPE AND FINISH PRIOR TO PURCHASING.
3. FIRE PROTECTION CONTRACTOR TO PROVIDE COVERAGE AS INDICATED ON
DRAWING.
4. SEE ARCHITECTURAL DRAWINGS FOR SMOKE AND FIRE RATED WALLS.
5. SPRINKLER SYSTEMS SHALL BE EQUIPPED WITH FLOOR CONTROL VALVE
ASSEMBLIES ( SEE SHEET FP2.1 FOR DETAIL) AT ALL CONNECTIONS TO RISERS.
SPRINKLER HEAD SCHEDULE (FOR THIS SHEET)
SYMBOL
QTY
MFG. SIN TYPERESPONSE TEMPERATURE K-FACTOR DESCRIPTION
109 VICTAULIC V2740 PENDANT
QUICK
155 °F 4.9
WHITE, SEMI-RECESSED PENDANT SPRINKLER (RESIDENTIAL TYPE)
27 VICTAULIC V2707 PENDANT
QUICK
155 °F 5.6
WHITE, SEMI-RECESSED PENDANT SPRINKLER (COMMERCIAL TYPE)
1 VICTAULIC V2707 PENDANT
QUICK
155 °F 5.6
BRASS, LAUNDRY CHUTE PENDANT SPRINKLER
4 VICTAULIC V2703 UPRIGHT
QUICK
155 °F 5.6
BRASS, UPRIGHT SPRINKLER
KING
301
303
305
KING
307
KING
309
KING
311
KING
313
KING
315
317
319
KING
321
KING
323
KING
325
327
329
KING
331
KING
333
KING
330
KING
328
326
KING
324
KING
322
320
318
ACC. QQ INLINE
SUITE
316
KING
310
KING
308
KING
306
ACC. KING
304
302
KING
314
ELECTRICAL
3005
LINEN
3004
COMPUTER/
COMM ROOM
GYP-1
ACT-1
ICE
D04
L60L60
L60
L57
L60 L60
L57
L60 L60
D04
L57
L60 L60
L60L60
D04
L57
L60 L60
L60 L60
D04
L60 L60
L60
L57
L60
L54
L54
L54
L54
L54
L54
L57
L60L60
L60 L60
D04
GYP-1
L60 L60
L57
L60 L60
D04
L60
L57
L60 L60
L60
D04
L60
L57
L57
L57
L29 L29
L33
L33 L33
L33
L31
L31
ACT-1ACT-1ACT-1ACT-1
GYP-1
GYP-1
ACT-1ACT-1ACT-1ACT-1ACT-1ACT-1ACT-1ACT-1ACT-1 ACT-1 ACT-1
4" CLASS 1 MANUAL WET
STANDPIPE
4" CLASS 1
COMBINATION RISER
FP1.3
1
SCALE: 1/8"= 1'-0"
FIRE PROTECTION - SPRINKLER - 3RD FLOOR
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
71
4 ch
erry stre
et, ch
atta
no
og
a, te
nn
esse
e 3
74
02
p.4
23
6
34
0
80
6 f.4
23
7
52
8
49
9 w
ww
.rive
r-st-a
rch
ite
ctu
re
.co
m
Release Date:
Project No.:
3/3
1/2
01
5 1
0:1
7:2
4 A
M
12055 G
AT
EW
AY
W
ES
T B
LV
D, E
L P
AS
O , T
X
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZA
RA
GO
ZA
H
OT
EL P
AR
TN
ER
S, LLC
FIRE PROTECTION
FP1.3
SPRINKLER
3RD FLOOR
FIRE PROTECTION PLAN NOTES
1. ALL TAMPER AND FLOW SWITCHES MUST BE CONNECTED TO A MONITORED FIRE
ALARM SYSTEM.
2. FIRE PROTECTION CONTRACTOR TO OBTAIN OWNER/ARCHITECT APPROVAL OF
SPRINKLER TYPE AND FINISH PRIOR TO PURCHASING.
3. FIRE PROTECTION CONTRACTOR TO PROVIDE COVERAGE AS INDICATED ON
DRAWING.
4. SEE ARCHITECTURAL DRAWINGS FOR SMOKE AND FIRE RATED WALLS.
5. SPRINKLER SYSTEMS SHALL BE EQUIPPED WITH FLOOR CONTROL VALVE
ASSEMBLIES ( SEE SHEET FP2.1 FOR DETAIL) AT ALL CONNECTIONS TO RISERS.
SPRINKLER HEAD SCHEDULE (FOR THIS SHEET)
SYMBOL
QTY
MFG. SIN TYPERESPONSE TEMPERATURE K-FACTOR DESCRIPTION
109 VICTAULIC V2740 PENDANT
QUICK
155 °F 4.9
WHITE, SEMI-RECESSED PENDANT SPRINKLER (RESIDENTIAL TYPE)
27 VICTAULIC V2707 PENDANT
QUICK
155 °F 5.6
WHITE, SEMI-RECESSED PENDANT SPRINKLER (COMMERCIAL TYPE)
1 VICTAULIC V2707 PENDANT
QUICK
155 °F 5.6
BRASS, LAUNDRY CHUTE PENDANT SPRINKLER
4 VICTAULIC V2703 UPRIGHT
QUICK
155 °F 5.6
BRASS, UPRIGHT SPRINKLER
KING
401
403
405
KING
407
KING
409
KING
411
KING
413
KING
415
417
419
KING
421
KING
423
KING
425
427
429
KING
431
KING
433
KING
430
KING
428
426
KING
424
KING
422
420
418
ACC. QQ INLINE
SUITE
416
KING
410
KING
408
KING
406
ACC. KING
404
402
KING
414
ELECTRICAL
4005
LINEN
4004
COMPUTER/
COMM ROOM
GYP-1
ACT-1
ICE
D04
L60L60
L60
L57
L60 L60
L57
L60 L60
D04
L57
L60 L60
L60L60
D04
L57
L60 L60
L60 L60
D04
L60 L60
L60
L57
L60
L54
L54
L54
L54
L54
L54
L57
L60L60
L60 L60
D04
GYP-1
L60 L60
L57
L60 L60
D04
L60
L57
L60 L60
L60
D04
L60
L57
L57
L57
L29 L29
L33
L33 L33
L33
L31
L31
ACT-1ACT-1ACT-1ACT-1
GYP-1
GYP-1
ACT-1ACT-1ACT-1ACT-1ACT-1ACT-1ACT-1ACT-1ACT-1 ACT-1 ACT-1
4" CLASS 1 MANUAL WET
STANDPIPE
4" CLASS 1
COMBINATION RISER
FP1.4
1
SCALE: 1/8"= 1'-0"
FIRE PROTECTION - SPRINKLER - 4TH FLOOR
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
71
4 ch
erry stre
et, ch
atta
no
og
a, te
nn
esse
e 3
74
02
p.4
23
6
34
0
80
6 f.4
23
7
52
8
49
9 w
ww
.rive
r-st-a
rch
ite
ctu
re
.co
m
Release Date:
Project No.:
3/3
1/2
01
5 1
0:1
7:2
4 A
M
12055 G
AT
EW
AY
W
ES
T B
LV
D, E
L P
AS
O , T
X
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZA
RA
GO
ZA
H
OT
EL P
AR
TN
ER
S, LLC
FIRE PROTECTION
FP1.4
SPRINKLER
4TH FLOOR
FIRE PROTECTION PLAN NOTES
1. ALL TAMPER AND FLOW SWITCHES MUST BE CONNECTED TO A MONITORED FIRE
ALARM SYSTEM.
2. FIRE PROTECTION CONTRACTOR TO OBTAIN OWNER/ARCHITECT APPROVAL OF
SPRINKLER TYPE AND FINISH PRIOR TO PURCHASING.
3. FIRE PROTECTION CONTRACTOR TO PROVIDE COVERAGE AS INDICATED ON
DRAWING.
4. SEE ARCHITECTURAL DRAWINGS FOR SMOKE AND FIRE RATED WALLS.
5. SPRINKLER SYSTEMS SHALL BE EQUIPPED WITH FLOOR CONTROL VALVE
ASSEMBLIES ( SEE SHEET FP2.1 FOR DETAIL) AT ALL CONNECTIONS TO RISERS.
SPRINKLER HEAD SCHEDULE (FOR THIS SHEET)
SYMBOL
QTY
MFG. SIN TYPERESPONSE TEMPERATURE K-FACTOR DESCRIPTION
109 VICTAULIC V2740 PENDANT
QUICK
155 °F 4.9
WHITE, SEMI-RECESSED PENDANT SPRINKLER (RESIDENTIAL TYPE)
27 VICTAULIC V2707 PENDANT
QUICK
155 °F 5.6
WHITE, SEMI-RECESSED PENDANT SPRINKLER (COMMERCIAL TYPE)
1 VICTAULIC V2707 PENDANT
QUICK
155 °F 5.6
BRASS, LAUNDRY CHUTE PENDANT SPRINKLER
4 VICTAULIC V2703 UPRIGHT
QUICK
155 °F 5.6
BRASS, UPRIGHT SPRINKLER
AEED,
Advanced Energy Engineering & Design, Inc
CHATTANOOGA, TN 37405
BUS. (423) 752-3438
FAX (423) 752-1369
P.O. BOX 4934
408 McCALLIE AVE
inc.
AEED JOB NO.029-15
COPYRIGHT NOTICE
THE DRAWINGS ARE THE
PROPERTY OF RIVER STREET
ARCHITECTURE LLC. ANY USE,
REUSE, REPRODUCTION,
DISPLAY OR SALE OF THESE
DRAWINGS WITHOUT THE
EXPRESS WRITTEN CONSENT
OF THE ARCHITECT IS
STRICTLY PROHIBITED.
71
4 ch
erry stre
et, ch
atta
no
og
a, te
nn
esse
e 3
74
02
p.4
23
6
34
0
80
6 f.4
23
7
52
8
49
9 w
ww
.rive
r-st-a
rch
ite
ctu
re
.co
m
Release Date:
Project No.:
3/3
1/2
01
5 1
0:1
7:2
4 A
M
12055 G
AT
EW
AY
W
ES
T B
LV
D, E
L P
AS
O , T
X
CO
UR
TY
AR
D B
Y M
AR
RIO
TT
ZA
RA
GO
ZA
H
OT
EL P
AR
TN
ER
S, LLC
FIRE PROTECTION
FP2.1
DETAILS
SCALE: NONE
RISER DETAIL
PIPE
FIRE RESISTANT
SILICONE FOAM SEALER
CUT OPENING IN MASONRY WALL
LARGER THAN SLEEVE, THEN FORM &
FILL WITH EXPANSIVE TYPE GROUT.
PIPE INSULATION (WHERE REQ'D)
ESCUTCHEON PLATE ON ONE
OR BOTH SIDES WHERE
PIPING IS EXPOSED
PIPE SLEEVE
ANCHOR LUGS (MIN. 3 REQ'D)
EXISTING POURED CONCRETE
OR C.M.U. WALL.
NOTES:
1. FOR INTERIOR WALLS
AND BELOW GRADE
WALLS.
SEAL SPACE AROUND
PIPE WITH FIREPROOF
CAULKING.
PIPE SLEEVE
FINISHED FLOOR
5/8" ∅ BOLT
FURNISH LEAD
SHIELDS FOR BRASS
OR COPPER PIPING
PIPE
3/8" THK. STEEL X 1/2" MIN.
PIPE CLAMP WITH EXTENTION
ARMS
SCALE: NONE
PIPE RISER SUPPORT DETAIL
SCALE: NONE
PIPE SLEEVE THROUGH WALL DETAIL
SCALE: NONE
UPRIGHT & PENDANT INSTALLATION DETAIL
PENDANT
SPK'R. HEAD
1" BRANCH
LINE
1" BRANCH
LINE
INCREASER
UPRIGHT
SPK'R. HEAD
BRANCH LINE
SPRINKLER MAIN
WELDED.
EMERY PAPER. ATTACHMENT MAY BE SPOT
SMOOTH SCREW HEADS WITH FILE OR
SHEET METAL SCREWS AT 2" ON CENTER.
A
FRONT ELEVATION
SECTION A-A
6"
RADIUS.
CHUTE
WALL
1"
20 GAUGE STEEL
SPRINKLER
SHIELD
3"
18 "
SCALE: NONE
PENDANT HEAD IN LAUNDRY CHUTE DETAIL
FINISHED FLOOR
2 1/2" FDV (WITH 1-1/2" ADAPTER)
4" FIRE MAIN
2" DRAIN RISER
SECTIONAL DRAIN VALVE
TEST VALVE
UNION WITH CORROSION RESISTANT ORIFICE
SIGHT GLASS
3" 3"
TO SYSTEM
WATERFLOW SWITCH-VANE TYPE
INDICATING TYPE FLOOR CONTROL
VALVE WITH TAMPER SWITCH
(1ST FLOOR ONLY)
CHECK VALVE
ISOLATION BUTTERFLY
VALVE
INSPECTOR'S TEST CONNECTION
TO SYSTEM
TYPICAL FLOOR CONTROL VALVE DETAIL
SCALE: NONE
FIRE SERVICE PIPING
12" A.F.F.
BLIND FLANGE UNTIL READY
TO CONNECT TO INSIDE FIRE
PIPING
CAST IRON FLANGE
AND SPIGOT PIECE
CAST IRON BELL
AND SPIGOT PIPE
RODS
TYPICAL FLOOR PENETRATION DETAIL
SCALE: NONE
VICTAULIC 7C7 RISER MOUNTED
AIR COMPRESSOR (1/6 HP)
TO CLASS 1 MANUAL STANDPIPE SYSTEM
TO CLASS 1 COMBINATION STANDPIPE SYSTEM
VICTAULIC 768 2-1/2" DRY SYSTEM VALVE
1ST FLOOR WET SYSTEM
VICTAULIC 751 4" ALARM CHECK
VALVE
MONITORED BUTTERFLY VALVE (TYP.)
SYSTEM DRAIN
TO CITY MAIN
FINISHED FLOOR
4" FIRE MAIN
24"
PLUG
TEE
TO WET SYSTEM
SPRINKLER BARREL
TYCO DSB DRY SPRINKLER
BOOT & SEALANT KIT
SEALANT
INSULATED FREEZER
STRUCTURE
DRY TYPE
PENDENT SPRINKLER WITH WIDE
FLANGED RECESSED ESCUTCHEON2-1/4" DIA. MOUNTING PLATE CLEARANCE
HOLE
INSULATED FREEZER CEILING STRUCTURE
1-3/4" DIA. SPRINKLER
BARREL CLEARANCE HOLE
2-NYLON ZIP-TIE CLAMPS AS PER
INSTALLATION MANUAL
COOLER/FREEZER DRY PENDANT DETAIL
SCALE: NONE
SPRINKLER MAIN
1" BRANCH
LINE
SEMI-RECESSED
PENDANT SPK'R. HEAD
FINISHED SURFACE
FINISHED SURFACE
1" BRANCH
LINE
SIDEWALL PENDANT DETAIL
SCALE: NONE