A BRIEF PRESENTATION A BRIEF PRESENTATION ON SEPTIC ON SEPTIC
TANKSTANKS
![Page 2: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/2.jpg)
SEPTIC TANKA septic tank is a special form of primary sedimentation tank with a longer detention time, in which digestion of settled sludge also take place. A septic tank is a combined sedimentation cum digestion tank. This tank has,therefore, larger capacity than ordinary primary sedimentation tank, so as to accommodate and hold the settled sludge for its subsequent digestion. This unit, therefore, is grouped under the primary treatment unit. The digestion of settled sludge is carried out by anaerobic decomposition process , giving risk to septi city or septic condition, that’s why this unit is known as septic tank.
![Page 3: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/3.jpg)
Since the foul gases are evolved during the
digestion process, the tank is kept completely
covered on the top, with a provision of a high
vertical vent shaft for the escape of these gases.
Due to anaerobic digestion of sludge
and consequent release of gases, appreciable
reduction in the volume of sludge takes place.
![Page 4: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/4.jpg)
DESIGN AND CONSTRUCTION DESIGN AND CONSTRUCTION FEATURESFEATURES
• A septic tank is a settling-cum-digestion tank, its rational design is based on the following three function it is expected to perform:
1. Sedimentation to remove the maximum possible amounts of suspended solids from the sewage,
2. Digestion of settled sludge resulting in a much reduced volume of dense, digested sludge, and
3. Storage of sludge and accumulating in between successive cleaning thereby preventing their escape.
Hence the tank should be large enough to provide all the above three requirements
![Page 5: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/5.jpg)
SEWAGE FLOWSEWAGE FLOW• The maximum sewage flow into a septic tank is
based on the number of plumbing fixtures discharging simultaneously, rather than the number of users and per capita wastewater expected to reach the tank.
• Facility Equivalent fixtures unit
1.Water Closet 12.Bath Kitchen ½3.Wash Basin ½4.Slope Tank 1
![Page 6: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/6.jpg)
TANK DIMENSIONSTANK DIMENSIONS
• The tank capacity, and tank dimensions are based on the three functions of sedimentation, sludge digestion and sludge storage.
![Page 7: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/7.jpg)
• 1.SEDIMENTATION:
At temperature of 25 C the surface area required will be 0.92 m for every 10 lpm peak flow rate. A minimum depth of 25-30 cm is necessary. The length is mainted 2-4 times the breadth.
0
2
![Page 8: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/8.jpg)
• 2.Sludge digestion :
The time required for anaerobic digestion is temperature dependent.
![Page 9: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/9.jpg)
0 10 20 30 40 50 60 70 80 90 1000
10
20
30
40
50
60
70
Temp.Temp.
Digestion TimeDigestion Time
well seeded sludgewell seeded sludgeIncluding lag.Including lag.
well seeded sludgewell seeded sludgeExcluding lag.Excluding lag.
Average sludgeAverage sludgeIncluding lag.Including lag.
![Page 10: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/10.jpg)
• 3.Storage of sludge and scum:A sludge storage capacity of 0.0002 x 365 x 100 = 7.30 m /100person for an interval of cleaning of 1 year is provided below the sedimentation zone.
3
![Page 11: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/11.jpg)
TOTAL CAPACITYTOTAL CAPACITY
• The total capacity will be equal to the sum of the above three requirements, plus a free board of not less than 30 cm .
No additional capacity for seed sludge is provided, if care is taken during desludging to leave about 5 to 10% digested sludge or a minimum of 25 to 50 mm depth of sludge on the tank bottom.
![Page 12: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/12.jpg)
Sludge withdrawalSludge withdrawal
sludge is withdrawn from the septic tank either half yearly or yearly. For small domestic tank, desludging may be done at least once in 2 to 3 years. The digested sludge is withdrawn through a dip pipe of at least 15 cm dia. under a hydrostatic pressure of at least 45 cm.
s
![Page 13: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/13.jpg)
CONSTRUCTION DETAILSCONSTRUCTION DETAILS
The tank may be constructed of brick masonry, stone masonry or even in concrete. They are provided with water tight cover, along with a ventilation pipe, extending at least 2 m above the top of highest building within a radius of 20 m for smaller capacity, only one compartment is provided, while for larger capacities, two compartments are provided, with a partition wall
at a distance of about 2/3 the length from the inlet. The inlet and outlet are located at the two opposite ends.
![Page 14: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/14.jpg)
OUTLETOUTLETINLETINLET
8.3M8.3M
L/5L/5
.9M.9M
2L/32L/3
3.4M3.4M
MANHOLE
SECTOINAL PLANSECTOINAL PLAN
YY
YY
XXXX
![Page 15: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/15.jpg)
CAST IRON STEPSCAST IRON STEPS SECTION X-XSECTION X-X
G.LG.LBAFFLEBAFFLE
SLOPESLOPE
.75.75 .40.403030
1515.3M.3M
.8M.8M
50MM Dia Min50MM Dia MinVENTILATING PIPEVENTILATING PIPE
![Page 16: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/16.jpg)
EFFLUENT DISPOSAL IN SEPTIC EFFLUENT DISPOSAL IN SEPTIC TANKSTANKS
• The effluent coming out of the tank will be septic and malodorous. Final purification of the effluent and the removal of pathogen is affected by the following methods:
1.Soil absorption systems2.Upflow filters3.Biological filters
![Page 17: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/17.jpg)
ADVANTAGES OF SEPTIC TANKADVANTAGES OF SEPTIC TANK1.Septic tank can be constructed easily.
2.The cost is quite small and within the reach of private householders.
3.There are no moving part for its operation.
4.The effluent can be disposed off easily, without much trouble.
5.When once installed, they give long, carefree service.
![Page 18: 87444869-Septic-Tank ok.ppt](https://reader033.vdocuments.us/reader033/viewer/2022051416/55cf9c81550346d033aa11ad/html5/thumbnails/18.jpg)
DISADVANTAGES OF SEPTIC DISADVANTAGES OF SEPTIC TANKTANK
1.The size required is large and uneconomical.
2.Their functioning and action is erratic.
3.The effluent is dark and foul smelling with high BOD.
4.Leakage of gases from the top cause bad smell and environmental pollution.