80mbit/s digital optical links for control, timing and ...€¦ · anne marie sandvik cern....
TRANSCRIPT
-
10.September 2002 Digital Optical Control System 1
80Mbit/s Digital Optical Links for Control, Timing and Trigger of the CMS Tracker
Part I. System OverviewPart II. Prototype Testing
Anne Marie SandvikCERN
-
10.September 2002 Digital Optical Control System 2
Tracker Optical Links
A-Opto Hybridprocessingbuffering
TTCRx
ADC
Rx ModuleFED
TTCRx
FEC
PLL Delay
MUX2:1
PLL
APVamplifierspipelines128:1 MUX
Detector Hybrid
DCU
processingbuffering
12
96
3
8/12
64/96
Back-End
CCUCCU
CCU CCU
Control4
TTC
DAQ
Digital Control2300 links @40MHz
D-Opto Hybrid
12
Front-End
Analogue Readout40000 links @ 40MS/s
TRx Module
-
10.September 2002 Digital Optical Control System 3
Tracker Requirements
Fibres to or from same optohybrid2Skew (ns)
rms0.5Jitter (ns)
10-910-12Bit-error-rate
802Speed (Mbit/s)
To share analogue readout link components1310 nmWavelength (nm)
NotesMaxTypMinItem
•Tracker environment – T ~ -10°C
– B = 4T
– 150kGy & 3x1014 π/cm2 radiation dose
– 10 years min. lifetime
-
10.September 2002 Digital Optical Control System 4
System implementation
96121 12
Final p-i-n diodes and back-end Transceiver still to be procured
-
10.September 2002 Digital Optical Control System 5
Part Two
Prototype testing
-
10.September 2002 Digital Optical Control System 6
Prototype Testing• DOH (3/5 Parts) • TRx (5/10 Parts)
Commercial 4 way2.5 Gbit/s Transceiverfrom NGK Optobahn
ASIC made at CERNDimensions:
Footprint: 35x25mmHeight : 5mm
XMinimum Data Rate
XReset
XXSaturation
XXSensitivity
XXOptical Power
NGK TransceiverDigital optohybridMeasurements
-
10.September 2002 Digital Optical Control System 7
Measurement setup DOH
Optical attenuators
BERT
Reference Optohybrid
Optohybrid under test
I2C
Ck DaDa Ck
I2C
A
A
-
10.September 2002 Digital Optical Control System 8
TRx test setup
Reference OptohybridI2C
BERT
TRx
Ck DaDa Ck
A
-
10.September 2002 Digital Optical Control System 9
Tx Characteristics
-12
-10
-8
-6
Sign
al A
mpl
itude
[dBm
]
-10 -9 -8 -7 -6 -5 -4 -3 -2Average launched power [dBm]
DOH Typical eye-pattern from TRx
Average launched power: -6.7dBm
-12
-10
-8
-6
Sign
al A
mpl
itude
[dBm
]
-10 -9 -8 -7 -6 -5 -4 -3 -2Average launched power [dBm]
TRx
Signal Amplitude: -8.5dBm
-
10.September 2002 Digital Optical Control System 10
10-11 10
-8 10
-5 10
-2
BER
-35 -30 -25 -20 -15 -10 -5Average Launched Power [dBm]
Rx Sensitivity & Saturation
Example of bit-error-rate versus average launched power
Typ.Operating
Range
Sens
itivi
ty
Satu
ratio
n
-
10.September 2002 Digital Optical Control System 11
Rx characteristics•DOH
•RX40 Specs •Sensitivity ~ -20 dBm•Saturation ~ -3dBm
•TRx spec :•Sensitivity ~ -18 dBm•Saturation ~ -5 dBm
-28
-24
-20
Sens
itivi
ty [d
Bm]
-6 -4 -2 0 2Saturation Level [dBm]
DOH
-28
-24
-20
Sens
itivi
ty [d
Bm]
-6 -4 -2 0 2Saturation Level [dBm]
TRx
-
10.September 2002 Digital Optical Control System 12
Full link
• Optical power margins measured in each channel – optical attenuation increased to point where errors occur or link fails
- From DOH to TRx - From TRx to DOH- Clock: ~17.5dB - Clock: ~9.5dB- Data: ~17.5dB - Data: ~ 10dB
• Two Links tested with attenuation for 15 hours without any errors BER < 3* 10-13
• Full link made with DOH, TRX, 100m cable + 3 ‘patch-panels’
BERTNGK-
OptobahnTRx
CERNDOH
D
D
CK
CK
out
in Tx
RxTx
Rx
A
Electricalconnections
100m opticalfibre ribbon
MPO-12
FC/PC
-
10.September 2002 Digital Optical Control System 13
Summary• 80Mbit/s digital links developed at CERN for CMS Tracker control
– will also be used by ECAL, Preshower and Pixels
• Philosophy has been to (re)use analogue link components
• Extensive testing of the prototype DOH and NGK-TRx – Devices work well and compatible with intended link system– Testing procedures in place for production
• Full prototype link with DOH, TRX and realistic cabling tested– operates with a large safety margin – BER < 10-12
• The remaining specs and interfaces to be frozen end of 2002, procurement of devices to start in 2003
-
10.September 2002 Digital Optical Control System 14
• More information on the Digital Optical Links:
http://cern.ch/cms-opto