800 series indicating temperature controls and thermometers · indicating temperature controls and...

8
INDICATING TEMPERATURE CONTROLS AND THERMOMETERS 8 0 0 - B - 0 7 800 Series 800 Series FEATURES Simple adjustment and control Rugged construction for demanding applications Improve efficiency with best-in-class repeatability Meet environment requirements with enclosure design options Match process requirements with an assortment of available ranges

Upload: dangmien

Post on 15-Apr-2018

263 views

Category:

Documents


4 download

TRANSCRIPT

INDICATING TEMPERATURE CONTROLS AND THERMOMETERS

8 0 0 - B - 0 7

80

0 S

erie

s800 Series

featureS

• Simpleadjustmentandcontrol

• Ruggedconstructionfordemandingapplications

• Improveefficiencywithbest-in-classrepeatability

• Meetenvironmentrequirementswithenclosure

designoptions

• Matchprocessrequirementswithanassortmentof

availableranges

2 w w w . u e o n l i n e . c o m 8 0 0 - B - 0 7

800 Series

For applications that require a visual display of process temperatureandsetpoint,the800Seriesoffersahighlyreadablefourinchsetting/indication scale. It is available in two versions: a Lexan® enclosurefor enclosure type 1 or 4 applications (with option M300), and withLexan® window and epoxy-coated aluminum enclosure for Div. 1explosionproofapplications.Fortemperatureindicationonly,theT800thermometer incorporates the same performance and constructionfeaturesofthe800Series.

800Seriesmodelscontrolandindicatethetemperatureoffoodserviceappliances,ovens,packagingmachines,HVACequipment,andvarioustemperatureapplicationswithinprocessplants.

overview features

• Temperatureindicationand

controlswitching

• SingleordualSPDToutput

• Stainlesssteelbulb&capillary

• Simpletoadjustviaexternalknob

• ExplosionproofmodelsareUL

listed,cULcertified,andATEX

compliant

• OptionalRussian,Ukrainian,and

Chinese,flameprooforintrinsic

safetycompliance

• Optionalthermowellsandunion

connectorsavailable

Singlesetpointversion Explosionproofversion

Lexan®isaregisteredtrademarkofSABICInnovativePlasticsIPBV

80

0 S

eri

es

8 0 0 - B - 0 7 w w w . u e o n l i n e . c o m 3

8 0 0 S e r i e s

specificationsStorage temperature -65to160°F(-54to71°C)

ambient temperature limitS -40to160°F(-40to71°C);setpointtypicallyshiftslessthan1%ofrangefora50°F(28°C) ambienttemperaturechange

Set point repeatability ±1%ofadjustablerange

Shock Setpointrepeatsafter15G,10millisecondduration

Vibration Setpointrepeatsafter2.5G,5-500Hz

encloSure Types800,802:Lexan®blackfinish;clearLexan®faceplate TypesT800,820E,822E:Diecastaluminum,epoxycoatedenclosure,gasketed;Lexan®coverand faceplate

encloSure claSSification Types800,802,T800:Designedtomeetenclosuretype1requirements(enclosuretype4by specifyingoptionM300).Types820E,822E:Designedtomeetenclosuretype4X;ClassIDiv.1 productsmeetenclosuretype7;ClassII,Div.1productsmeetenclosuretype9.CertifiedtoIP66 requirements

indication accuracy ±1%ofadjustablerange

Switch output OneortwoSPDT;dualswitchmaybeseparatedupto100%ofrange;excepttype822Ewhere switch#2canbesetupto25%ofrangespanbelowswitch#1setpoint.Switchesmaybewired “normallyopen”or“normallyclosed.”NOTAPPLICABLETyPET800.

dual Switch adjuStment Type802:Dualswitchcontrolshaveseparateknob&temperaturepointersforeachswitchset point(standard);turninnergreenknobforsetting#1switch;outerblackknobforswitch#2. Type822Ecommonadjustmentsingleknobandpointerforsetpoint

electrical rating 15A125/250/480VACresistive.ElectricalswitcheshavelimitedDCcapabilitiesat24-30VDC, 2Aresistiveand1Ainductive.125VDC,0.5Aresistive,0.03Ainductive.Consultfactoryfor additionalinformation.DCratingsarenotlistedonnameplate.NOTAPPLICABLETyPET800.

weight Types800,802,T800:Approx.3lbs.,4oz.(1,47kg) Types820E,822E: Approx.7lbs(3,18kg)

electrical connection Types800,802:7/8”diameterknockoutonlefthandside;18AWGcolor-codedleadwires,approx. 9inchesexposedwithstrainrelief(optionM100addsterminalblockwiring). NOTAPPLICABLETyPET800. Type820E:two3/4”NPTE/Cwithterminalblock.Type822E:one3/4”NPTE/Cwithterminal block

bulb and capillary 6feet304stainlesssteel

temperature fill Model1BS:solventfilled;models2-8:non-toxicoilfilled

temperature deadband Typically1%ofrangeunderlaboratoryconditions(70°Fambientcirculatingbathatrateof1/2°F perminutechange)

4 w w w . u e o n l i n e . c o m 8 0 0 - B - 0 7

800 Series8

00

Se

rie

s

united StateS and canada800 & 802 modelsul listed, cul certifiedUL873,file#E10667;CSAC22.2No.24

820e & 822e models

ClassI,Division1and2,GroupsB,C&DClassII,Division1and2,GroupsE,F&GClassIIIClassI,Zone1,GroupIIB+H2T6EnclosureType4Xul listed, cul certifiedUL1203&50;CSANo.25&30-file#E43374

europe820e & 822e modelsateX directive (94/9/ec)II2GExdIICT6GbII2DExtbIIICT85°CDbIP66Tamb=-40°Cto+75°CULInternationalDEMKOA/S(N.B.#0539)Certificate#DEMKO09ATEX0815573XRev.2EN60079-0,60079-1,60079-31

low Voltage directive (lVd) (2006/95/ec)UECcomplianttoLVDProductsratedlowerthan50VACand75VDCareoutsideofthescopeoftheLVDTheLowVoltageDirectivedoesnotapplytoproductsforuseinhazardouslocations

ruSSia820e & 822e modelsRostechnadzorPermitandGOST-RCoC(optional – code m406)1ExdIICT6XTamb=-40°Cto+71°CNANIOCCVECertificationCenterCertificate#POCCUS.05.B04260OCTP51330.0,51330.1,51330.10&51330-14

ukraine820e & 822e modelsGosnadzorohrantrudaPermit(optional - code m404)1ExdIICT6XExiaIICT6GaTamb=-40°Cto+71°CCertificate#720byBE(TCCExEE)OCT12.2.007.0,22782.0,22782.6

china820e & 822e modelsCQSTCertified (optional - code m408)ExdIICT6DIPA21TA+85°CTamb=-40°Cto+75°CGB3836.1,3836.2&12476.1Certificate#CNEx09.2180X

approvals UEdeclarationsandthird-partyissuedAgencycertificationsareavailablefordownloadatwww.ueonline.com/prod_approval.

temperature model chart

Model Adjustable Set Point Range Max. Temp. Scale Div. Bulb Size

°F °C °F °C °F °C ODxLength

1BS* -180to120 -117.8to48.9 170 76.7 5 5 3/8x3-3/4””

2BS -125to350 -87.2to176.7 400 204.4 10 5 3/8x2-7/16”

3BS -125to500 -87.2to260 550 287.8 10 5 3/8x2-1/8”

4BS -40to120 -40to48.9 170 76.7 5 2 3/8x6-3/4”

5BS -40to180 -40to82.2 230 110 5 2 3/8x5”

6BS 0to250 -17.8to121.1 300 148.9 5 2 3/8x4-1/2”

7BS 0to400 -17.8to204.4 450 232.2 10 5 3/8x3”

8BS 50to650 10to343.3 700 371.1 10 10 3/8x3-1/4”

Standardcapillarylengthis6ft.,optionalcapillarylengthsandprotectionareavailable,consultUE.

*NOTAVAILABLETyPET800

Note:TypeT800isanindicatingthermometeronlyandassuchcarriesnoapprovallistings.

8 0 0 - B - 0 7 w w w . u e o n l i n e . c o m 5

8 0 0 S e r i e s

how to order

type temperature

Type800-Bulbandcapillary;oneSPDToutput;externalindication Type802-Bulbandcapillary;twoSPDToutputs;externalindication Type820E-Bulbandcapillary;oneSPDToutput;externalindication,explosionproof Type822E-Bulbandcapillary;twoSPDToutputs;externalindication,explosionproof TypeT800-Bulbandcapillary;thermometeronlywithexternalindication

optionS

Switch optionS* deScription

0140 Goldcontacts,1A125VACresistive.NOTAVAILABLETyPE800,820E,T8000500 Closedeadband,5A125/250VACresistive.NOTAVAILABLETyPET8001070 10A125VDCorVACresistive;deadbandandminimumsetpointmayincrease.NOTAVAILABLE TyPES802,820E,T8002000 20A125/250VACresistive.NOTAVAILABLETyPET800

other optionS

M007 Drilled7/8”electricalopeningonrightside.NOTAVAILABLETyPES820E,822EandT800M100 Terminalblockwiring.NOTAVAILABLETyPE820E,822E(standard)ANDT800M201 Factorysetoneswitch;specifyincreasingordecreasingtemperatureandsetpoint.NOTAVAILABLE TyPE802,822E,T800M202 Factorysettwoswitches;specifyincreasingordecreasingtemperatureandsetpoint.NOTAVAILABLE TyPE800,820E,T800M300 EnclosureType4construction;includeswatertightconduitfittingandgasketing.NOTAVAILABLE TyPES820E,822E(whichalreadymeetenclosuretype4X)M320 Tamperresistantcover.NOTAVAILABLETyPEST800M404 FlameproofcomplianceforUkraineperGosnadzorohrantrudastandards.NOTAVAILABLETyPES800, 802,T800M406 FlameproofcomplianceforRussiaperRostechnadzorpermit(RTN).NOTAVAILABLETyPES800,802, T800M408 FlameproofcomplianceforChinaperCQSTstandards.NOTAVAILABLETyPES800,802,T800M444 PaperIDtagM446 StainlesssteelIDtag&wireattachment;limitedto2linesof25characterseachmax.M550 Oxygenservicecleaning;alcoholcleaningtoremoveresiduefromtheprocessconnectionM900 Watertightconduitfitting;converts7/8”holeto1/2”NPTfitting.NOTAVAILABLETyPES820E, 822E,T800 *AllswitchoptionshavelimitedDCcapabilities.DCratingsarenotlistedonnameplate.Consultfactoryfordetails.

building a part number

Selectatype

Refertothe“Type”sectionbelow.

Determinetypenumberbasedonswitchoutput,enclosure,adjustmentandreference.

Fillinthetypeportionofyourpartnumberwiththecorrespondingnumber.

Selectamodel

Refertothe“ModelCharts.”

Determinemodelbasedonadjustablerange,deadbandandproofpressure.

Fillinthemodelportionofyourpartnumberwiththecorrespondingnumber.

Selectanoption

Refertothe“Options”section.

Determineoptionnumberbasedonswitchoutput,optionalmaterialsorotherproductenhancements.

Fillintheoptionportionofyourpartnumberwiththecorrespondingnumber.

Leave“option”portionblankifnooptionsareneeded.FORMULTIPLEOPTIONS:CallUnitedElectricControls.

6 w w w . u e o n l i n e . c o m 8 0 0 - B - 0 7

800 Series8

00

Se

rie

s

options for temperature models

union connectorS** Option Replacement Number Description BrassW027 SD6213-27 1⁄2”NPTw/3⁄4”bushingW045 SD6213-45 3⁄4”NPTW051 SD6213-51 1⁄2”NPT 304StainlessSteelW028 SD6213-28 1⁄2”NPTw/3⁄4”bushingW046 SD6213-46 3⁄4”NPTW050 SD6213-50 1⁄2”NPTthermowellS** For all bulb & capillary switches Brass W075 SD6225-75 1⁄2”NPTwith3⁄4”NPTadapterbushing,4”BTW191 SD6225-191 1⁄2”NPT,4”BTW118 SD6225-118 1⁄2”NPTwith3⁄4”NPTadapterbushing,7”BTW192 SD6225-192 1⁄2”NPT,7”BT 316StainlessSteelW076 SD6225-76 3⁄4”NPT,4.5”BT W193 SD6225-193 1⁄2”NPT,4.5”BT W119 SD6225-119 3⁄4”NPT,7.5”BT W177 SD6225-177 1⁄2”NPT,7.5”BT optional lengthS:Optionalcapillarylengthto50’maybeavailablein304st/st.ArmororTeflon®capillaryprotectionmaybeavailabletolengthslessthanorequaltocapillarylength.ConsultUEforadditionalinformationandavailability.

ConsultUEregardingrepeatabilityandambienteffectsoncapillarylengthsover30’

**Dimensionaldrawingsforunionconnectorsandthermowellsmaybefoundatwww.ueonline.com

8 0 0 - B - 0 7 w w w . u e o n l i n e . c o m 7

8 0 0 S e r i e s

dimensional drawings(Dimensionaldrawingsforallmodelsmaybefoundatwww.ueonline.com)

800 SeriesExternal Set Point Adjustment & Temperature Indication

Type 820 E Type 822 E

†TypeT800hasnosetpointindicatingpointer.

Dimension A

models inches mm

1BS 3-3/4 95.3

2BS 2-7/16 62.0

3BS 2-1/8 54.0

4BS 6-3/4 171.5

5BS 5 127.0

6BS 4-1/2 114.3

7BS 3 76.2

8BS 3-1/4 82.6

SET POINTINDICATING

POINTER (SWITCH #2)

REDSET POINT

INDICATINGPOINTER

(SWITCH #1)GREEN

SET POINTADJUSTMENT KNOBS

TEMPERATUREINDICATINGPOINTER. (BLACK)

Types 802

Types 800 & T800

CP012131500Besuretovisitwww.ueonline.comforthelatestinformation.

180DexterAvenue,P.O.Box9143Watertown,MA02471-9143USATelephone:617926-1000Fax:617926-2568www.ueonline.com

recommended practiceS and warningS

United Electric Controls Company recommends careful considerationof the following factors when specifying and installing UE pressureand temperature units. Before installing a unit, the Installationand Maintenance instructions provided with unit must be read andunderstood.

• Toavoiddamagingunit, proof pressure andmaximum temperaturelimitsstatedinliteratureandonnameplatesmustneverbeexceeded,evenby surges in the system.Operationof theunitup tomaximumpressure or temperature is acceptable on a limited basis (e.g.,start-up, testing) but continuous operationmustbe restricted to thedesignatedadjustablerange.Excessivecyclingatmaximumpressureortemperaturelimitscouldreducesensorlife.

• A back-up unit is necessary for applications where damage toa primary unit could endanger life, limb or property. A high orlow limit switch is necessary for applications where a dangerousrunawayconditioncouldresult.

• The adjustable range must be selected so that incorrect,inadvertentormalicioussettingatanyrangepointcannotresultinanunsafesystemcondition.

• Install unit where shock, vibration and ambient temperaturefluctuations will not damage unit or affect operation. Whenapplicable,orientunitsothatmoisturedoesnotentertheenclosurevia the electrical connection. When appropriate, this entry pointshouldbesealedtopreventmoistureentry.

• Unitmustnotbealteredormodifiedaftershipment.ConsultUEifmodificationisnecessary.

• Monitor operation to observe warning signs of possible damageto unit, such as drift in set point or faulty display. Check unitimmediately.

• Preventative maintenance and periodic testing is necessary forcritical applications where damage could endanger property orpersonnel.

• Electrical ratings stated in literature and on nameplate must notbe exceeded. Overload on a switch can cause damage, even onthefirstcycle. Wireunitaccordingtolocalandnationalelectricalcodes,usingwiresizerecommendedininstallationsheet.

• Donotmountunitinambienttemp.exceedingpublishedlimits.

limited warrantySeller warrants that the product hereby purchased is, upon delivery,free from defects in material and workmanship and that anysuch product which is found to be defective in such workmanshipor material will be repaired or replaced by Seller (Ex-works, Factory,Watertown, Massachusetts. INCOTERMS); provided, however, that thiswarranty applies only to equipment found to be so defective withina period of 24 months from the date of manufacture by the Seller.Seller shall not be obligated under this warranty for alleged defectswhich examination discloses are due to tampering, misuse, neglect,improper storage, and in any case where products are disassembledby anyone other than authorized Seller’s representatives. EXCEPT FORTHE LIMITED WARRANTy OF REPAIR AND REPLACEMENT STATEDABOVE, SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITHRESPECTTOTHEPRODUCT,INCLUDINGALLIMPLIEDWARRANTIESOFMERCHANTABILITyORFITNESSFORANyPARTICULARPURPOSE.

limitation of Seller’S liabilitySELLER’S LIABILITy TO BUyER FOR ANy LOSS OR CLAIM, INCLUDINGLIABILITy INCURRED IN CONNECTION WITH (I) BREACH OF ANyWARRANTyWHATSOEVER,EXPRESSEDOR IMPLIED, (II)ABREACHOFCONTRACT, (III)ANEGLIGENTACTORACTS (ORNEGLIGENT FAILURETOACT)COMMITTEDBy SELLER,OR (IV)ANACT FORWHICHSTRICTLIABILITyWILLBE INPUTTEDTOSELLER, ISLIMITEDTOTHE“LIMITEDWARRANTy”OFREPAIRAND/ORREPLACEMENTASSOSTATEDINOURWARRANTyOFPRODUCT.INNOEVENTSHALLTHESELLERBELIABLEFOR ANy SPECIAL, INDIRECT, CONSEQUENTIAL OR OTHER DAMAGESOFALIKEGENERALNATURE,INCLUDING,WITHOUTLIMITATION,LOSSOFPROFITSORPRODUCTION,ORLOSSOREXPENSESOFANyNATUREINCURREDByTHEBUyERORANyTHIRDPARTy.

UE specifications subject to change without notice.

international officeS

CHINA UnitedElectricControls,Shanghai Office Room1011,10thFlr, HuaiHaiZhonghuaBuilding No.885,RenminRoad,LuwanDistrict Shanghai200010,P.R.China Phone:+8621-62558059 email:[email protected]

UnitedElectricControls,Beijing Office Room1006,JainhaoInternationalBldg. BlockD,No.116 Zizhuyuanlu,HaidianDistrict Beijing,China100089 Phone:+86-10-5893-0518 email:[email protected]

EUROPE UnitedElectricControls 05-806Komorow Kujawska5,Poland Phone:+48224994804 email:[email protected]

INDIA #402,AriesAvenue-1 UnitedColony,Sama Baroda(Gujarat),India390008 Phone:+91(-265)-2788654 email:[email protected]

ASIA-PACIFIC UnitedElectricControls,FarEast No.1-2-2,2ndFloor Jalan4/101C CherasBusinessCentre Batu5,JalanCheras 56100KualaLumpur,Malaysia Phone:603-9133-4122 email:[email protected]

RUSSIA&SCANDINAVIA UnitedElectricControls,Moscow Elninskayastr.,15-140 Moscow,121552,Russia Phone:+7(495)640-88-06 email:[email protected]

u.S. SaleS officeS

UnitedElectricControls 31OldStageRoad HamptonFalls,NH03844 Phone:617-899-1132 email:[email protected]

UnitedElectricControls 1022VineyardDrive Conyers,GA30013 Phone:770-335-9802 email:[email protected]

UnitedElectricControls 5829GrazingCourt Mason,OH45040 Phone:513-535-5486 email:[email protected]

UnitedElectricControls 102SalazarCourt Clayton,CA94517 Phone:925-408-5997 email:[email protected]

UnitedElectricControls 27SummitTerrace Sparta,NJ07871 Phone:973-271-2550 email:[email protected]

UnitedElectricControls 33018WeatherbyCourt Fulshear,Texas77441 Phone:832-457-6138 email:[email protected]

canada

68MosleyCrescent Brampton,Ontario CanadaL6y5C8 Phone:905-301-1274 FAX:905-455-5131