3,350+ OPEN ACCESS BOOKS 108,000+ INTERNATIONAL AUTHORS AND EDITORS 115+ MILLION DOWNLOADS BOOKS DELIVERED TO 151 COUNTRIES AUTHORS AMONG TOP 1% MOST CITED SCIENTIST 12.2% AUTHORS AND EDITORS FROM TOP 500 UNIVERSITIES Selection of our books indexed in the Book Citation Index in Web of Science™ Core Collection (BKCI) Chapter from the book Advances in Nuclear Fuel Downloaded from: http://www.intechopen.com/books/advances-in-nuclear-fuel PUBLISHED BY World's largest Science, Technology & Medicine Open Access book publisher Interested in publishing with IntechOpen? Contact us at [email protected]

Upload: others

Post on 22-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

3,350+OPEN ACCESS BOOKS

108,000+INTERNATIONAL

AUTHORS AND EDITORS115+ MILLION

DOWNLOADS

BOOKSDELIVERED TO

151 COUNTRIES

AUTHORS AMONG

TOP 1%MOST CITED SCIENTIST

12.2%AUTHORS AND EDITORS

FROM TOP 500 UNIVERSITIES

Selection of our books indexed in theBook Citation Index in Web of Science™

Core Collection (BKCI)

Chapter from the book Advances in Nuclear FuelDownloaded from: http://www.intechopen.com/books/advances-in-nuclear-fuel

PUBLISHED BY

World's largest Science,Technology & Medicine

Open Access book publisher

Interested in publishing with IntechOpen?Contact us at [email protected]

Page 2: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

7

Behaviors of Nuclear Fuel Cladding During RIA

Sun-Ki Kim Korean Atomic Energy Research Institute

Republic of Korea

1. Introduction

A Reactivity-initiated accident (RIA) is a nuclear reactor accident that involves an unwanted

increase in reactor power. The abrupt power increase can lead to damage the reactor core as

well as fuel cladding, and in severe cases, even lead to disruption of reactor.

During a steady-state operation of light water reactors, the mechanical behavior of the

zirconium-based fuel cladding degrades due to a combination of oxidation, hydriding, and

radiation damage. In an effort to increase the operating efficiency through the use of longer

fuel cycles, and to reduce the volume of waste associated with the core reloads, utilities have

a strong incentive to increase the average discharge burn-up of the fuel assemblies. Further

increases in the operating efficiency of power reactors can also be achieved by increasing the

coolant outlet temperature. However, both of these changes in a reactor operation enhance

the cladding degradation, which may increase the likelihood of a cladding failure during

design-basis accidents.

One such postulated design-basis accident scenario is the reactivity-initiated accident (RIA)

in a pressurized water reactor (PWR) caused by the ejection of a control rod from the core,

which would cause a rapid increase of the reactivity and the thermal energy in the fuel

(Meyer et al., 1986). The increase in fuel temperature resulting from an RIA induces a rapid

fuel expansion, causing a severe pellet-cladding mechanical interaction (PCMI). This PCMI

forces the cladding to experience a multiaxial tension such that the maximum principal

strain is in the hoop (i.e., transverse) direction of the cladding tube. The survivability of a

fuel cladding irradiated to a high burn-up under postulated RIA conditions is thus a

response to a combination of the mechanics of a loading and the material degradation

during a reactor operation.

While such data is available for the axial deformation behavior of cladding tubes, relatively

little data has been reported in the open literature on the uniaxial tension behavior in the

hoop direction of nuclear fuel cladding. In the 1990s, experimental programs were also

initiated in Japan, France, and Russia to investigate the behavior of highly irradiated nuclear

fuel under reactivity-initiated accident conditions.

Accordingly, it is essential to investigate the uniaxial tension behavior in the hoop direction

of nuclear fuel cladding. In this chapter, some mechanical tests results for simulating the

cladding behaviors during reactivity-initiated accident are introduced.

www.intechopen.com

Page 3: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Advances in Nuclear Fuel

144

2. International test program: CABRI program

In a pressurized water reactor, the reactivity initiated accident (RIA) scenario of primary

concern is the control rod ejection accident (Glasstone & Sesonske, 1991). At this early heat-

up stage of the RIA, the clad tube material is still at a fairly low temperature (<650 K), and

the fast straining imposed by the expanding fuel pellets may therefore cause a rapid and

partially brittle mode of clad failure (Chung & Kassner, 1998). To investigate fuel behaviors

during these RIA condition, CABRI REP-Na test program was initiated in early 1990s. The

main purpose of the CABRI REP-Na test program was to study the validity of the RIA

acceptance criteria on high-burnup 17×17 PWR fuel, with emphasis on the behavior of fuel

during the early stage of the transient up to fuel failure (Schmitz & Papin, 1999). Recently,

international test program in CABRI has being prepared in order to simulate the fuel

behaviors in water loop at reactor pressure level by replacing the existing Na loop with

water loop. Through a total of 15 technical advisory group meetings, the test matrix in the

CABRI water loop program has being established.

In this chapter, main test results in CABRI REP-Na program are presented, and also the

current status on the CABRI water loop program is briefly introduced.

2.1 CABRI REP Na loop test program

2.1.1 Overview of CABRI REP Na loop test

First of all, a total of twelve tests have been carried out in the program. Eight of the tests

were performed on UO2 fuel and four tests on MOX fuel, pre-irradiated to burnups ranging

from 28 to 65 MWd/kgU. In addition to the CABRI REP-Na program, two tests were

performed in November 2002 on PWR fuel rods with burnups around 75 MWd//kgU.

These test rods, denoted CIPO-1 and CIPO-2, had advanced claddings such as ZIRLO and

M5 cladding, respectively. The CABRI test reactor is a pool-type light water reactor,

designed with a central flux area that can accommodate the insertion of a test device.

2.2 Main outcomes of CABRI REP Na loop test

Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8

tests. Among the four tests with fuel failure, there had UO2 fuel and one MOX fuel. All

failures were with Zircaloy-4 cladding, whereas no failure occurred in the three tests with

M5 or ZIRLO cladding. The three UO2 failures occurred at enthalpy below 80 cal/g and on

fuel that had a burnup of about 60 MWd/kgU and significant oxide thickness from 80 to 130

μm. However, several other CABRI tests were run at comparable burnup and oxide

thickness range, without resulting in fuel failure. Oxide spalling appears to be distinctive

element that separates the failed and non-failed fuel in CABRI UO2 tests, in that all three fuel

rods that failed had spalling, while the rods that did not fail had uniform non-spalled oxide.

Only one test for MOX fuel among four tests resulted in fuel failure. The failure occurred on

a fuel rod that had a burnup of 55 MWd/kgU and moderate corrosion level of 50 μm oxide

thickness. This is the only CABRI failure occurring on a non-spalled cladding. However, this

failure occurred at 113cal/g, which is a rather high enthalpy level, where a failure may not

be surprising, considering that this level in near the upper envelope of all CABRI data.

Failures were not associated to a particular pulse width. The three UO2 fuel rod failures

www.intechopen.com

Page 4: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Behaviors of Nuclear Fuel Cladding During RIA

145

occurred at all three pulse widths that have been used in CABRI test program, i.e. 9, 30, and

75 ms. The main outcomes from CABRI Na loop test program are listed in Table 1.

2.3 Current status of CABRI water loop test program

CABRI international program (CIP) in water loop test has been managed by IRSN in France with collaboration of EDF, CEA and the participating countries with support by OECD/NEA. This program focuses on the high burnup fuel and cladding behaviors in PWR condition during RIA. The test conditions are 155 bar and 280°C. Five test series were

Test and date

Rod and Burn-up

Pulsewidth(ms)

Energy Deposition

cal/g

Corrosion μm

Results and observations

Na-1 (11/93)

GRA 5 64 MWd/kg

9.5 110

(at 0.4s) 80

spalling Brittle failure at HF = 30 cal/g

Fuel dispersal (6g)

Na-2 (6/94)

BR3 33 MWd/kg

9.1 211

(at 0.4s) 4

No failure, HMAX = 199 cal/g Max. strain : 3.5%, FGR : 5.5%

Na-3 (10/94)

GRA 5 53 MWd/kg

9.5 120

(at 0.4s) 40

No failure, HMAX = 124 cal/g Max. strain : 2%, FGR : 13.7%

Na-4 (7/95)

GRA 5 62 MWd/kg

75 95

(at 1.2s) 80

no spalling No failure, HMAX = 85 cal/g

Max. strain : 0.4%, FGR : 8.3%

Na-5 (5/95)

GRA 5 64 MWd/kg

9.5 105

(at 0.4s) 20

No failure, HMAX = 108 cal/g Max. strain : 1%, FGR : 15.1%

Na-6 (03/96)

MOX 47 MWd/kg

35 125

(at 0.66s) 35

No failure, HMAX = 133 cal/g Max. strain : 3.2%, FGR : 21.6%

Na-7 (1/97)

MOX 55 MWd/kg

40 165

(at 1.2s) 50

Failure at HF = 113 cal/g Strong flow ejection

Na-8 (07/97)

GRA 5 60 MWd/kg

75 106

(at 0.4s) 130

lim. spallingFailure at HF ≤ 82 cal/g

HMAX = 98 cal/g, No fuel dispersal

Na-9 (04/97)

MOX 28 MWd/kg

34 197 at 0.5s241 at 1.2s

〈20 No failure, HMAX = 197 cal/g

Max. strain : 7.4%, FGR : ~34%

Na-10 (07/98)

GRA 5 62 MWd/kg

31 107 at 1.2s80

no spalling Failure at HF = 81 cal/g

HMAX = 98 cal/g, No fuel dispersal

Na-11 M5

63 MWd/kg31 104 15

No failure, HMAX = 93 cal/g Max. strain : ~0.5%

Na-12 MOX

65 MWd/kg62 106

80 no spalling

No failure, HMAX = 103 cal/g

CIP0-1 (11/02)

ZIRLO 75 MWd/kg

32 98 80

no spalling No failure, HMAX = 90 cal/g

CIP0-2 (11/02)

M5 77 MWd/kg

28 89 20 No failure, HMAX = 81 cal/g

Table 1. Main outcomes from CABRI REP Na test program

www.intechopen.com

Page 5: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Advances in Nuclear Fuel

146

established including qualification test, CIP Q for various fuel pellet, cladding, corrosion level and burnup. The test matrix CABRI international program (CIP) in water loop are listed in Table 2. The test sequence is not fixed, therefore it may be changed.

Test Series

Test Test Rod Objectives

CIPQ REP Na6 rod, span 3, 3cycles MOX, Zr4

CWL qualification + phenomenology

CIP1 CIP1-2 (option)

CIP0-2 sister rod, UO2 77GWd/t, M5

Phenomenology, Code validation

CIP2 CIP2-1 UO2 85 GWd/t, M5 = reference or ENUSA rod , 80GWd/t, Zr-Nb

Product qualification, code validation

CIP4 CIP4-1 CIP4-2

MOX-E M5 EDF rod (55GWd/t)MOX-SBR-Beznau rod (54Gwd/t, Zr4)

Product qualification Product qualification, physical understanding

CIP5 CIP5-1 VVER Lovisa, 50GWd/t, Zr-1%Nb

Product qualification

CIP3 CIP3-1 CIP0-1 sister rod, span 5 Code validation, safety criteria, post-failure events

CIP3-2 REP Na 7 sister rod Code validation, safety criteria, post-failure events

CIP3-3 Vandellos CIP0-1 sister rod, span3, UO2, 75 GWd/t

Code validation, safety criteria, phenomenology

CIP3-4 EDF rod, M5 63-68 GWd/t

Product qualification

CIP3-5 ENUSA rod, 67 GWd/t Zr-Nb

Product qualification, physical understanding

Table 2. Test matrix CABRI international program

3. Evaluation of mechanical properties of nuclear cladding

Except for international test program in pulse reactors, some mechanical tests such as ring tensile test, high-speed burst test, and expansion due-to compression test were applied in order to investigate the stress and strain in pellet-cladding mechanical interaction during RIA. In this chapter, the results on the ring tensile test and the high-speed burst test are introduced.

3.1 Evaluation of mechanical properties by Ring tensile test

To obtain the mechanical strengths such as the 0.2% offset yield strength and ultimate tensile strength were evaluated, and the uniform elongation and total elongation were also

www.intechopen.com

Page 6: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Behaviors of Nuclear Fuel Cladding During RIA

147

evaluated for the ductility. The hoop stress-strain curves at various temperatures are shown in Fig. 1.

0 30 60 90 120 150 180 2100

200

400

600

800

1000

1200

1400Strain rate=0.01/s

Ho

op

str

ess (

MP

a)

Hoop strain (%)

RT(Un-RT-01) RT(Un-RT-02)

135oC(Un-135-03)

135oC(Un-135-04)

200oC(Un-200-05)

200oC(Un-200-06)

300oC(Un-300-07)

300oC(Un-300-08)

300oC(Un-300-17)

350oC(Un-350-09)

350oC(Un-350-10)

350oC(Un-350-18)

400oC(Un-400-11)

400oC(Un-400-12)

600oC(Un-600-13)

600oC(Un-600-14)

800oC(Un-800-15)

800oC(Un-800-16)

RT(Ir-RT-02)

135oC(Ir-135-03)

200oC(Ir-200-04)

300oC(Ir-300-07)

300oC(Ir-300-08)

350oC(Ir-350-09)

350oC(Ir-350-10)

400oC(Ir-400-01)

600oC(Ir-600-05)

800oC(Ir-800-06)

Fig. 1. Hoop stress-strain curves at various test temperatures

The evaluation results of the yield strength and the ultimate tensile strength are shown in Fig. 2 and 3.

0 100 200 300 400 500 600 700 800 9000

100

200

300

400

500

600

700

800

900Strain rate=0.01/s

0.2

% y

ield

str

en

gth

(M

Pa

)

Temperature (oC)

Unirradiated Irradiated

Fig. 2. Yield strength of the un-irradiated and high burn-up fuel cladding

www.intechopen.com

Page 7: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Advances in Nuclear Fuel

148

0 100 200 300 400 500 600 700 800 9000

100

200

300

400

500

600

700

800

900

1000

1100Strain rate=0.01/s

Ultim

ate

tensile

str

ength

(M

Pa

)

Temperature (oC)

Unirradiated

Irradiated

Fig. 3. Ultimate tensile strength of the un-irradiated and high burn-up fuel cladding

The results show that the 0.2% offset yield strength and the ultimate tensile strength abruptly decrease with an increasing temperature. The ultimate tensile strength was

evaluated to be 942.70 MPa at RT, 678.83 MPa at 400°C, but, it is abruptly diminished to

282.64 MPa at 600°C, which is achievable in the RIA condition. Especially, it decreases to

58.30 MPa at 800°C, an extreme condition, which corresponds to 6% of the ultimate tensile strength at room temperature. This means that the mechanical strength of the high burn-up Zircaloy-4 nuclear fuel cladding sharply decreases in the RIA-relevant temperature ranges. The evaluation results of the uniform elongation and total elongation are shown in Fig. 4 and 5.

0 100 200 300 400 500 600 700 800 9000.00

0.05

0.10

0.15

0.20

0.25Strain rate=0.01/s

Pla

stic u

nifo

rm e

long

ation

(m

m/m

m)

Temperature (oC)

Unirradiated Irradiated

Fig. 4. Uniform elongation of the un-irradiated and high burn-up fuel cladding

www.intechopen.com

Page 8: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Behaviors of Nuclear Fuel Cladding During RIA

149

0 100 200 300 400 500 600 700 800 9000.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0Strain rate=0.01/s

Pla

stic t

ota

l e

lon

ga

tion

(m

m/m

m)

Temperature (oC)

Unirradiated

Irradiated

Fig. 5. Total elongation of the un-irradiated and high burn-up fuel cladding

The results show that both the increases in uniform elongation and total elongation with an

increasing temperature. Especially, they abruptly increase at 600°C, but become lower beyond this temperature. This peculiar behavior was also observed in the PROMETRA program (Averty et al., 2003) which is a mechanical property relevant test program in conjunction with the CABRI program simulating a RIA. The results of hoop directional mechanical strength and ductility of irradiated Zircaloy-4 with comparison with PROMETRA database are shown in Fig. 6 and Fig. 7, respectively. As shown in the figure, the behavior of this study is consistent with the PROMETRA data. It is believed that this behavior is caused by the elongation minimum phenomenon by the dynamic strain aging of

the Zr-base cladding material beyond 600°C.

0 100 200 300 400 500 600 700 800 900

0

200

400

600

800

1000

0

200

400

600

800

1000

Temperature (oC)

Ultim

ate

Ten

sile

Str

en

gth

(M

Pa

)

0.2

% O

ffse

t Y

ield

Str

en

gth

(M

Pa

)

0.2% offset YS (This study)

UTS (This study)

0.2% offset YS (PROMETRA, 3 Cycles Zircaloy-4)

UTS (PROMETRA, 3 Cycles Zircaloy-4)

Fig. 6. Comparison of mechanical strength with the PROMETRA database

www.intechopen.com

Page 9: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Advances in Nuclear Fuel

150

0 100 200 300 400 500 600 700 800 900

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0.0

0.2

0.4

0.6

0.8

1.0

1.2

Temperature (oC)

Tota

l E

long

atio

n (

mm

/mm

)

Un

iform

Elo

ng

atio

n (

mm

/mm

)

UE(This study)

TE(This study)

UE(PROMETRA, 3 Cycles Zircaloy-4)

TE(PROMETRA, 3 Cycles Zircaloy-4)

Fig. 7. Comparison of mechanical ductility with the PROMETRA database

The stereoscope photographs of the specimens after the ring tensile test are shown in Fig. 8. Fig. 8 represents the fracture patterns of the non-irradiated and high burn-up Zircaloy-4

cladding specimens. As shown in the figure, four fracture patterns such as 45° shear type fracture, cup & cone type fracture, cup & cup type fracture and chisel edge type fracture were observed in the non-irradiated cladding.

The fracture type was found to depend strongly on the deformation temperature. At room

temperature non-irradiated Zircaloy-4 cladding tends to be fractured by 45° shear type

fracture or Cup & cone type fracture. Cup & cone type fracture was dominant at 135°C and

200°C. Both cup & cone type fracture and cup & cup type fracture was observed at 300°C.

Only cup & cup type fracture was observed at 350°C and 400°C. At 600°C chisel edge type

fracture was observed unlike at lower temperatures with few fracture surface area. At 800°C the fracture type is unclear. These fracture types are summarized in Table 3.

Temperature Fracture type

Non-irradiated cladding High burn-up cladding

25°C 45° shear type fracture

Cup & cone type fracture

Brittle fracture

135°C Cup & cone type fracture

200°C Cup & cone type fracture

300°C Cup & cone type fracture Cup & cup type fracture

350°C Cup & cup type fracture

400°C Cup & cup type fracture

600°C Chisel edge type fracture

800°C Unidentified

Table 3. Fracture types for the ring tensile tests of the Zircaloy-4 fuel cladding

www.intechopen.com

Page 10: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Behaviors of Nuclear Fuel Cladding During RIA

151

Fig. 8. Stereoscope photograph of the specimens after the ring tensile test

High burn-up cladding Non-irradiated cladding

135°C

200°C

300°C

350°C

400°C

600°C

R.T.

www.intechopen.com

Page 11: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Advances in Nuclear Fuel

152

In conclusion, the fracture type of non-irradiated Zircaloy-4 cladding depends on the temperature, and the behavior is governed by a ductile fracture with a necking. On the contrary, the fracture patterns of the high burn-up Zircaloy-4 cladding showed completely different fracture patterns from the non-irradiated Zircaloy-4 cladding. The fracture type was observed to be vertical in the tensile direction without a necking at all of the test temperatures, which is convincing evidence of the brittle fracture behavior of high burn-up fuel cladding regardless of temperature.

This means that even at a high temperature, 600°C or 800°C, the fracture pattern showed a brittle fracture behavior. Accordingly, it was found that the high burn-up Zircaloy-4 cladding becomes very brittle even at the high temperatures achievable during a design-basis accident (Daum et al., 2002).

3.2 Evaluation of mechanical properties by high-speed burst test

Fig. 9 shows the time–pressure profile of the as-received Zircaloy-4 cladding under the rapid pressurization test. In the 350◦C test, the pressure increased prior to the test which is due to a thermal expansion of the hydraulic oil. It showed that the pressurization rate (slope at the initial part of the time–pressure curve) in this study was 5.4 GPa/s at room temperature and 3.1 GPa/s at 350◦C, where the pressurization rate at room temperature is 24,000 times higher than the conventional burst test. As the pressurization changes, the material properties also change. Ultimate hoop stress (UHS) at room temperature and 350◦C in this study were, respectively 1,067 and 620MPa, which are increased by 24.3 and 16.8% when compared to the conventional burst test. In the figure, theoretical burst behavior can be expected when the line was drawn from the elastic region and extended to the baseline, namely the 0MPa line. When we measure the interval between the intersection point and the point at a failure, the actual duration time of the fuel cladding during a rapid pressurization can be obtained. Duration time of the Zircaloy-4 cladding was 37.8 ms at room temperature and 32.5 ms at 350◦C, which closely simulates the power pulse of an actual RIA situation which is known as around 30–40 ms (MacDonald et al., 1970).

Fig. 9. Rapid burst properties of Zircaloy-4 cladding with the test temperature

www.intechopen.com

Page 12: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Behaviors of Nuclear Fuel Cladding During RIA

153

Merging all burst tests into a single graph, the change in the material property as UHS with

the pressurization is shown in Fig. 10. In the figure, there exists a linear relationship

between the UHS and the pressurization rate. The slope between the UHS and

pressurization rate was 0.03701 at room temperature and 0.02124 at 350◦C. From the result, a

higher pressurization rate induces a higher strain rate that results in an increase of the UHS.

Since the evaluation of the actual strain rate under biaxial burst is extremely difficult, it was

tried to indirectly evaluate the strain rate of the cladding and compare to the other data

(Kim et al., 2006).

Fig. 10. Changes in the maximum hoop stress of Zircaloy-4 with the pressurization rate and the test temperature.

The result was shown in Fig. 11. As shown in the figure, increase of the maximum stress

(both UTS in ring tensile test and UHS in burst test) with the strain rate is clearly shown.

Such a strain rate hardening is known as the hindrance of dislocation movement caused by

the dislocation multiplication. When an external strain is exerted, dislocations are

continuously generated and diffused through the crystal structure to the grain boundary. If

the rate of the dislocation generation exceeds the rate of diffusion to the grain boundary, the

dislocation density increases to cause an increase in the strength (Adams, 1965). However, it

is not clear why the maximum stress as well as the strain rate sensitivity of the burst test is

higher than that of the tensile test. Further works related to the strain rate dependency and

stress state of the zirconium cladding is needed.

During the waterside corrosion, the generated hydrogen is partly absorbed into the

cladding. For hydrogen contents exceeding significantly the solubility limit, hydride

precipitation is observed. These precipitated hydrides have a deleterious impact on the fuel

cladding ductility (Kim et al., 2006). To investigate the effect of hydrogen, hydrogen was

charged into the Zircaloy-4 cladding at a value of 300 and 600 ppm then a rapid

pressurization test was carried out. Fig. 12 shows the room temperature rapid

www.intechopen.com

Page 13: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Advances in Nuclear Fuel

154

pressurization profile of the hydrogen-charged Zircaloy-4 cladding. UHS of the 300 ppm-

charged specimen did not differ from the as-received condition except that the failure time

was more or less shortened. In the case of the 600 ppm-charged specimen, it was so brittle

that it failed at the elastic region. However, the effect of the hydrogen was soon eliminated

when the test temperature was increased. Fig. 13 shows the UHS of the as-received and 600

ppm-charged specimens with the test temperature.

Fig. 11. Changes in the maximum stress of Zircaloy-4 with the strain rate

Fig. 12. Rapid pressurization properties of Zircaloy-4 cladding with the hydrogen content

www.intechopen.com

Page 14: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Behaviors of Nuclear Fuel Cladding During RIA

155

Fig. 13. Maximum hoop stress vs. test temperature

As the test temperature increases, the expansion of the cladding as well as the decrease in

the viscosity of the hydraulic oil makes the pressurization rate become lower, which is

regarded it as unavoidable. At room temperature, UHS of the as-received condition was

23.2% larger than that of the 600 ppm-charged specimen. When the temperature increases

above 200 ◦C, their difference cannot be discriminated. At room temperature, the solubility

limit of hydrogen is negligible and most of the hydrogen is located in the zirconium

hydrides precipitates within the zirconium matrix. These hydrides are responsible for

material embrittlement. When it strained at room temperature, separation between the

hydride and the metal matrix as well as the failure of a brittle hydride itself will occur to

reduce the strength of the zirconium cladding (Kim et al., 2006). When the test temperature

increases, the property of the zirconium metal will be changed in that the ductility increases

due to an increase in the test temperature. Thus it induces a similar mechanical behavior

between the hydrogen-charged cladding and the as-received one. This is also implied from

the fracture appearance as shown in the Fig. 14.

In the case of as-received cladding, whatever the testing temperature was, it showed a

ductile rupture, creating a circumferentially ballooned state. Crack initiates and propagates

along the axial direction above the maximum hoop stress, soon this sharp crack became

blunt during a plastic deformation and it ceased to propagate. As-received specimen at

350◦C showed that the shape of the end part of the ballooned region was dull when

compared to the room temperature and 200◦C condition, which implies that the ductility

was increased to suppress the propagation of the axial crack at an elevated temperature. For

the 600 ppm-hydrogen-charged cladding pressurized at room temperature, the cladding

showed a brittle failure along the axial direction, indicating no plastic deformation. The

crack propagates along the axial direction first like the as-received condition, however, this

www.intechopen.com

Page 15: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Advances in Nuclear Fuel

156

sharp crack did not become blunt at the cladding material and it rapidly propagated to

induce a catastrophic, brittle failure. A void will nucleate preferentially at an interface

between a hydride and a zirconium matrix to develop a crack.

Fig. 14. Fracture appearance of Zircaloy-4 after the high-speed pressurization test

Void will continuously generate ahead of the crack tip when the crack propagates so that it

leads to a catastrophic failure along the axial direction. In the case of the hydrogen-charged

specimen burst at 200◦C, although the axial cracks developed at the side of the ballooned

region, their size was not longer than that at the room temperature. In the case of the

hydrogen charged specimen burst at 350◦C, the fracture appearance was no more different

than that of the as-received one. In the room temperature, axial split was well developed at

the end part cladding which indicates that residual metal is too brittle to suppress the axial

crack propagation once the crack initiates at the metal–hydride interface. At the high

temperature, such a catastrophic axial crack diminished. This seems that ductility of the

metal matrix was so high that it can restrain the crack from propagating, leaving a fracture

appearance similar to the as-received one.

www.intechopen.com

Page 16: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Behaviors of Nuclear Fuel Cladding During RIA

157

4. Conclusion

Main outcomes from CABRI REP-Na program and the current status of CABRI international

program (CIP) in water loop test program for investigating fuel and cladding behavior

during RIA were presented.

On the basis of the ring tensile tests for the high burn-up Zircalay-4 cladding from Ulchin

Unit 2 in Korea and the as-received non-irradiated Zircalay-4 cladding, the following

conclusions were drawn. As a result, the mechanical properties are abruptly degraded

beyond 600°C, which corresponds to a design basis accident condition such as a RIA. It

was found that the un-irradiated fuel cladding showed ductile fracture behaviors such as

45° shear type fracture, cup and cone type fracture, cup and cup type fracture and chisel

edge type fracture, while the high burn-up Zircalay-4 cladding showed a brittle fracture

behavior even at the high temperatures (e.g. over 600°C) which are achievable during a

RIA.

Rapid pressurization test was also carried out to evaluate the mechanical behavior of a

cladding under a fast strain rate as well as a biaxial stress state to simulate an out-of-pile

RIA behavior. The resuts shows that maximum hoop stress, pressurized at a rate of 5.4

GPa/s at room temperature and 3.1 GPa/s at 350 ◦C, increased by 24.3 and 16.8% when

compared to the conventional burst test results. It was also revealed that failure mode

switched from a ductile ballooning to a brittle failure which leads to an axial split of the

cladding when the hydrogen was added at a nominal value of 600 ppm when tested at room

temperature. As the test temperature increased, its effect was diminished.

5. Acknowledgment

This work was financially supported by the Ministry of Education, Science and Technology in Korea.

6. References

Adams, K. H. (1965). Dislocation Mobility and Density in Zinc Single Crystals. Ph.D. Thesis. California Institute of Technology

Averty X. et al. (2003). Tensile tests on ring specimens machined in M5 cladding irradiated 6 cycles, IRSN 2003/50

Chung, H. M. & Kassner, T. F. (1998). Cladding metallurgy and fracture behavior during reactivity-initiated accidents at high burnup. Nuclear Engineering and Design, Vol.186, pp. 411-427

Daum R. S. et al. (2002). On the Embrittlement of Zircaloy-4 Under RIA-Relevant Conditions. Zirconium in the Nuclear Industry : Thirteenth International Symposium, ASTM STP 1423, PA, pp.702-719

Glasstone, S. & Sesonske, A. (1991). Nuclear Reactor Engineering, 3rd ed., Krieger Publishing Company, Malabar, Florida, USA

Kim, et al. (2006). Effects of oxide and hydrogen on the circumferential mechanical properties of Zircaloy-4 cladding. Nuclear Engineering and Design, Vol.236, pp.1867–1873

www.intechopen.com

Page 17: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Advances in Nuclear Fuel

158

MacDonald, P. E. et al. (1970). Assessment of light-water-reactor fuel damage during a reactivity-initiated accident. Nuclear Safety, Vol.21, No.5, pp.582–602

Meyer R. O. et al. (1986). A Regulatory Assessment of Test Data for Reactivity Initiated Accidents. Nuclear Safety, Vol.37, No.4, pp.271-288

Schmitz, F. & Papin, J. (1999). High burnup effects on fuel behavior under accident conditions: the tests CABRI REP Na, Journal of Nuclear Materials, Vol.270, pp. 55-64

www.intechopen.com

Page 18: 79: ' # '6& *#7 & 8 · 2018. 4. 7. · 2.2 Main outcomes of CABRI REP Na loop test Fuel cladding failure occurred in four tests, whereas no failure occurred in the remaining 8 tests

Advances in Nuclear FuelEdited by Dr. Shripad T. Revankar

ISBN 978-953-51-0042-3Hard cover, 174 pagesPublisher InTechPublished online 22, February, 2012Published in print edition February, 2012

InTech EuropeUniversity Campus STeP Ri Slavka Krautzeka 83/A 51000 Rijeka, Croatia Phone: +385 (51) 770 447 Fax: +385 (51) 686 166www.intechopen.com

InTech ChinaUnit 405, Office Block, Hotel Equatorial Shanghai No.65, Yan An Road (West), Shanghai, 200040, China

Phone: +86-21-62489820 Fax: +86-21-62489821

Worldwide there are more than 430 nuclear power plants operating and more plants are being constructed orplanned for construction. For nuclear power to be sustainable the nuclear fuel must be sustainable and thereshould be adequate nuclear fuel waste management program. Continuous technological advances will leadtowards sustainable nuclear fuel through closed fuel cycles and advance fuel development. This focuses onchallenges and issues that need to be addressed for better performance and safety of nuclear fuel in nuclearplants. These focused areas are on development of high conductivity new fuels, radiation induced corrosion,fuel behavior during abnormal events in reactor, and decontamination of radioactive material.

How to referenceIn order to correctly reference this scholarly work, feel free to copy and paste the following:

Sun-Ki Kim (2012). Behaviors of Nuclear Fuel Cladding During RIA, Advances in Nuclear Fuel, Dr. Shripad T.Revankar (Ed.), ISBN: 978-953-51-0042-3, InTech, Available from:http://www.intechopen.com/books/advances-in-nuclear-fuel/behaviors-of-nuclear-fuel-cladding-during-ria