7396 medilec ml2000 brochureupdates.clipsal.com/clipsalonlinenz/files/brochures/m... · 2008. 7....

19
ML2000 Series MOULDED HOSPITAL ELECTRICAL ACCESSORIES clipsal.com/cis

Upload: others

Post on 13-May-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

ML2000 SeriesMOULDED HOSPITAL ELECTRICAL ACCESSORIES

cl ipsal .com/cis

Page 2: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

Introduction 2 - 3

Contents

ML2000 Series

• SOCKET OUTLETS 8 - 11

• SOCKET OUTLETS - CLEANER 10

• SOCKET OUTLETS - RCD PROTECTED 11

AS3003 Electrical Installations

PATIENT TREATMENT AREAS 5

ML2031RC Series

RESIDUAL CURRENT DEVICES 6

ML2031E08

AUDIBLE/VISUAL ALARMS 7

ML2000R0 Series

EQUIPOTENTIAL EARTH STUDS 12

ML2031EU

GAS OUTLET ADAPTOR PLATE 13

2000 Series

CLIPSAL ACCESSORIES 14 - 15

2000 Series

OEM ACCESSORIES 16

ML2000 Series

THE SIMPLE AND ECONOMICAL ALTERNATIVE 4

Page 3: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

Hospitals have undergone a dramatic

transformation in the past 20 years. The

development of less intrusive medical techniques

has meant that patient recovery times have been

greatly reduced. As a result, day surgery clinics are

now a feature of almost every hospital.

Hospital environments are now less intimidating

too. No longer clinical and antiquated, patient

accommodation is often of hotel standard. And

although there is a greater reliance on hi tech

support equipment, it is now designed to blend

with the surroundings to create a more relaxed

environment for both patients and medical staff.

The Medilec Range of hospital equipment is

designed to meet this growing demand for

hospital services and equipment that are

more attractive and less intimidating.

Introduction

Page 4: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET
Page 5: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

EC

ON

OM

ICA

L A

LT

ER

NA

TIV

EM

L20

00

Se

rie

s

ML2000 SERIES

Now an impressive part of the Medilec Range, the ML2000

Series is a complete range of Moulded Hospital Electrical

Accessories. The ML2000 Series is based on the Clipsal

2000 Series of electrical accessories but has additional

features to meet the special needs of hospital patient

treatment areas. As defi ned in AS/NZS3003 - “Electrical

installations: patient treatment areas of hospitals and

medical and dental practices”.

The ML2000 Series products, combined with the following

items, produce a very economical, reliable and modular

Medical Service Panel System that is not only quick and

easy to produce but also looks attractive.

Clipsal 2000 Series Surrounds and Mounting Boxes

or Brackets

Clipsal 2000 Electrical Accessories

OEM 2000 Series Nurse Call Points

OEM 2000 Series Gas Outlets

The s imple & economical alternative

MEETING HIGH STANDARDS

All the ML2000 Series electrical accessories comply with

the relevant Australian Standards for electrical safety (as

well as standards for patient treatment areas) including

AS/NZS3003 - “Electrical installations: patient treatment

areas of hospitals and medical and dental practices”,

and AS/NZS3190 - “Approval and test specifi cations for

residual current devices”.

4

Page 6: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

AS/NZS3003. ELECTRICAL INSTALLATIONS: PATIENT

TREATMENT AREAS OF HOSPITALS AND MEDICAL AND

DENTAL PRACTICES

The ML2000 Series product range is designed to meet

the requirements of AS/NZS3003. AS/NZS3003 sets out

the specialist electrical installation requirements often

found in the following premises:

Hospitals

Medical Practices

Dental Practices

Physiotherapy Practices

The areas within these premises that would need to

meet AS3003 are classifi ed as Body or Cardiac Protected

Areas. The procedures carried out to classify these areas

as Body or Cardiac Protected are as follows:

Within Body Protected Areas procedures are carried

out where a patient is connected to an item of

electromedical equipment which reduces the impedance

of the skin by either electrode paste or by the entrance

of conducting fl uids, metal needles, saline fi lled

catheters, etc.

Within Cardiac Protected Areas the same procedures

are carried out as in the Body Protected Areas but also

procedures where a patient has an electrical conductor

placed within the heart or is likely to come in contact

with the heart, eg. electrical wires such as cardiac pacing

electrodes and intracardiac ECG electrodes, or insulated

tubes fi lled with conducting fl uids.

Pa

tien

t trea

tme

nt a

rea

s E

LE

CT

RIC

AL

INS

TA

LL

AT

ION

S

5

Page 7: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

RE

SID

UA

L C

UR

RE

NT

DE

VIC

ES

(R

CD

s)M

L20

31

RC

Se

rie

s

6

ML2031RC SERIES

The ML2031RC range of RCDs are based on the Clipsal

2031RC range of RCDs for maximum protection against

electrocution. The advantage of the ML2031RC range is that

they have been specially designed with an additional Line

Supply Power Indicator.

The ML2031RC Series RCDs are designed to operate at

10mA which meets the requirements of AS/NZS3003 -

“Electrical installations: patient treatment areas of

hospitals and medical and dental practices”, and

AS/NZS3190 - “Approval and test specifi cations for

residual current devices”.

Features

10mA trip current

Amber indicator marked “SUPPLY POWER AVAILABLE”

Red indicator marked “LINE POWER AVAILABLE”

Inbuilt test facility

RCD protection of GPOs down stream.

Residual Current Devices (RCDs)

Trip Current 10mATrip Time < 40msOperational Voltage 250V a.c. 50HzMaximum Load 20ADimensions 116 x 76mm (30mm rear projection plus wiring)Complies to AS/NZS3190Australian Standards AS/NZS3003Approval No. S/1/2031RC SeriesStandard Colours WE - White Electric RD - Red DB - Dark Blue

Specifi cations

ML2031RC10

ML2031VRC10

CATALOGUE NO. DESCRIPTION

ML2031VRC10 Single gang, double pole, vertical, 250V, 20A, 10mA RCD

ML2031RC10 Single gang, double pole, horizontal, 250V, 20A, 10mA RCD

Wiring Diagram

RCD

Page 8: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

ML2031E08

ML2031VE08

ML2

03

1E

08

Se

ries

AU

DIB

LE

/VIS

UA

L A

LA

RM

S

7

ML2031E08 SERIES

The ML2031E08 range of Audible/Visual Alarms have

been developed to work in conjunction with the

ML2031RC range of RCDs. When the RCD trips it sets off

an audible and visual indicator. The advantage is that

it provides an excellent means of alerting hospital staff

whenever the RCD has actually tripped.

Features

Multiple 2 tone audible alarm indication

Flashing red visual alarm indication

Mute push-button marked “PRESS TO MUTE”

Audible/Visual Alarms

Operational Voltage 250V a.c. 50HzDimensions 116 x 76mm (34mm rear projection plus wiring)Complies to AS/NZS3100Australian Standard Approval No. SC/975/SStandard Colours WE - White Electric RD - Red DB - Dark Blue

Specifi cations

ML2031VE08 Single gang, vertical, audible/visual alarm, 250V

ML2031E08 Single gang, horizontal, audible/visual alarm, 250V

Wir ing Diagram

CATALOGUE NUMBER DESCRIPTION

Page 9: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

ML2000 SERIES

As with other ML2000 Series products, the range of

Socket Outlets is based on the Clipsal 2000 Series but

with additional features to meet the special needs of

hospital patient treatment areas. As defi ned in

AS/NZS3003 - “Electrical installations: patient treatment

areas of hospitals and medical and dental practices”.

When installing a group of socket outlets ideally one

ML2000 socket outlet plate should be used with the

remaining being standard Clipsal socket outlets. The

one ML2000 socket outlet plate will incorporate the

amber Power Available Neon, Circuit Identifi cation,

and protection classifi cation markings for the group of

socket outlets.

Features

Socket Outlets – connected to RCD Protected Supply:

Single or twin outlet

10 or 15 Amp

Single pole switched outlets

Marked “RCD PROTECTED”

Amber Power Available indicator

Optional Clipsal 30PID circuit identifi cation

Socket Outlets – connected to an Isolated

Protected Supply:

Single or twin outlet

Double pole switched outlets

10 Amp

Marked “ISOLATING TRANSFORMER PROTECTED”

Optional Clipsal 30PID circuit identifi cation

Note:

Not all variations are available. Refer to catalogue

number listing for exact options.

Socket Outlets

Page 10: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

ML2015 Single outlet, horizontal, power neon, RCD label, 250V, 10A

ML2015I Single outlet, horizontal, power neon, RCD label, circuit identifi cation, 250V, 10A

ML2015/15I Single outlet, horizontal, power neon, RCD label, circuit identifi cation, 250V, 15A

ML2015D Single double pole outlet, horizontal, power neon, isolated label, 250V, 10A

ML2025 Double outlet, horizontal, power neon, RCD label, 250V, 10A

ML2025I Double outlet, horizontal, power neon, RCD label, circuit identifi cation, 250V, 10A

ML2025RD Double outlet, horizontal, power neon, RCD label, red switch mechs, 250V, 10A

CATALOGUE NO. DESCRIPTION

ML2015V Single outlet, vertical, power neon, RCD label, 250V, 10A

ML2015VI Single outlet, vertical, power neon, RCD label, circuit identifi cation, 250V, 10A

ML2015/15VI Single outlet, vertical, power neon, RCD label, circuit identifi cation, 250V, 15A

ML2015VD Single double pole outlet, vertical, isolated label, 250V, 10A

ML2015VDI Single double pole outlet, vertical, isolated label, circuit identifi cation, 250V, 10A

ML2025V Double outlet, vertical, power neon, RCD label, 250V, 10A

ML2025VI Double outlet, vertical, power neon, RCD label, circuit identifi cation, 250V, 10A

ML2025VD Double double pole outlet, vertical, isolated label, 250V, 10A

Vert ical

Horizontal

ML2

00

0 S

erie

sS

OC

KE

T O

UT

LE

TS

9

ML2015VD

ML2025VD

ML2015/15VI

ML2025VI

ML2015VI

ML2025V

ML2015V

ML2015VDIML2025I

ML2015D

ML2015I

ML2025

ML2015/15I

ML2015

Operational Voltage 250V a.c. 50HzMaximum load 10 or 15 AmpsDimensions 116 x 76mm Complies to Australian Standard AS/NZS3112Approval No. S/1/2025 Series, S/1/2015 SeriesStandard Colours WE - White Electric, RD - Red, DB - Dark Blue

Specifi cations

Page 11: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

CATALOGUE NO. DESCRIPTION

ML2015C Single gang power outlet, horizontal, Cleaner label, 250V, 10A

ML2015/15C Single gang power outlet, horizontal, Cleaner label, 250V, 15A

ML2025C Double gang power outlet, horizontal, Cleaner label, 250V, 10A

SO

CK

ET

OU

TL

ET

SM

L20

00

C S

eri

es

10

Socket Outlets - CleanerML2000C SERIES

The ML2000C range of socket outlets are clearly

identifi able cleaner socket outlets as defi ned in AS/NZS

3003 “Electrical installations: patient treatment areas of

hospitals and medical and dental practices”. The cleaner

socket outlets are used to connect mains powered

cleaning equipment to dedicated cleaner power circuits.

FEATURES

Single or twin outlet

10 or 15 Amp

Single pole switched

Marked “CLEANING PURPOSES ONLY”

Beige in colour

Operational Voltage 250V a.c. 50Hz

Maximum load 10 or 15 Amps

Dimensions 116 x 76mm

Complies to AS/NZS 3112, AS/NZS 3003Australian Standard

Standard Colours BG - Beige

Specifi cations

ML2015/15C

ML2015C

ML2025C

Page 12: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

ML2

025RC

Se

ries

SO

CK

ET

OU

TLETS

11

ML2025RC SERIES

The compact ML2025RC10 incorporates a double socket

outlet and an RCD for maximum protection against

electrocution, on a single grid plate.

The ML2025RC10 RCD is designed to operate at 10mA

which meets the requirements of AS/NZS 3003 “Electrical

installations: patient treatment areas of hospitals and

medical and dental practices”.

FEATURES

10mA trip current

Twin 10A switched outlets

Amber indicator marked “POWER AVAILABLE”

Marked “RCD PROTECTED”

Inbuilt test facility

RCD protection of GPO’s down stream

CATALOGUE NO. DESCRIPTION

ML2025RC10 Double gang power outlet, 250V, 10A, 10mA RCD

Specifi cations

Trip Current 10mA

Trip Time < 40ms

Operational Voltage 250V a.c. 50Hz

Max load 10 Amps

Dimensions 116 x 76mm (30mm rear projection plus wiring)

Complies to AS/NZS 3190, AS/NZS 3003Australian Standard

Colours WE – White Electric RD – Red DB – Dark Blue

Socket Outlets - RCD Protected

Wiring Diagram

RCD

ML2025RC10

Page 13: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

EQ

UIP

OTE

NTI

AL

EA

RTH

STU

DS

ML2

00

0R

0 S

eri

es

12

ML2031VR01 Single gang, vertical, EP stud

ML2032VR02 Double gang, vertical, EP stud

ML2031R01 Single gang, horizontal, EP stud

ML2032R02 Double gang, horizontal, EP stud

CATALOGUE NO. DESCRIPTION

Dimensions 116 x 76mm (23mm rear projection)Complies to AS/NZS3003Australian Standard

Standard Colours WE – White Electric RD – Red DB – Dark Blue

Specifi cations

ML2000R0 SERIES

The ML2031R0 & ML2032R0 ranges of Equipo-

tential (EP) Earthing Studs have been developed

to meet the relevant requirements of EP Earthing

within hospitals as detailed AS3003 - “Electrical

installations: patient treatment areas of hospitals

and medical and dental practices”.

Features

Single or Twin EP Stud

EP Stud clearly identifi ed in colour green

Screw clamping system for effective EP

Earthing connections

Equipotential Earth Studs

ML2031VR01

ML2032VR02

ML2031R01

ML2032R02

Page 14: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

ML2

03

1E

U S

erie

sG

AS

OU

TL

ET

AD

AP

TO

R P

LA

TE

13

ML2031EU

The ML2031EU Gas Outlet Adaptor Plate has been

developed to allow the ESCO MEDICON range of gas

outlets to fi t to the ML2000 Series system. The blank

grid plate is pre-drilled with convenient mounting

holes to allow the Gas Outlet to be fi tted vertically

or horizontally.

Note: The plate does not accept the ESCO MEDICON

Venturi Suction and Venturi Gas Outlets.

ML2031EU Single gang grid plate

CATALOGUE NO. DESCRIPTION

Gas Outlet Adaptor Plate

ML2031EU

Standard Colours WE – White Electric RD – Red DB – Dark Blue

Specifi cations

Page 15: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

CL

IPS

AL

AC

CE

SS

OR

IES

ML2

03

1E

U S

eri

es

14

The ML2000 Series is based on the Clipsal 2000 Series

therefore the Medical Service Panels will incorporate

some of the Clipsal 2000 Series products. Detailed below

is a list of some of the more common Clipsal 2000

Series products.

Please refer to the Clipsal Trade Product Guide for a

complete listing of the Clipsal 2000 Series accessories.

Cl ipsal 2000 Series

Technical Data

Surrounds2000 1 gang, surround (116x76mm)2000/2 2 gang, vertical, surround (116 x 144mm)2000/3 3 gang, vertical, surround (116 x 219mm)2000/4 4 gang, vertical, surround (116 x 290mm)2000H2 2 gang, horizontal, surround (76 x 229mm)2000H3 3 gang, horizontal, surround (76 x 342mm)

Wall Boxes157 1 gang, wall box2157/2 2 gang, vertical, wall box2157/3 3 gang, vertical, wall box2157/4 4 gang, vertical, wall box2157H2 2 gang, horizontal, wall box2157H3 3 gang, horizontal, wall box

Mounting Brackets WALL BOARD154 1 gang, wall board mounting clip2154/2 2 gang, vertical, wall board mounting clip2154/3 3 gang, vertical, wall board mounting clip2154/4 4 gang, vertical, wall board mounting clip2154H2 2 gang, horizontal, wall board mounting clip2154H3 3 gang, horizontal, wall board mounting clip

CATALOGUE NUMBER & DESCRIPTION

2157/4

2154/4

2000/4

Page 16: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

20

00

Se

ries

15

CL

IPS

AL

AC

CE

SS

OR

IES

PLASTER MOUNT (Mounting Brackets cont.)155P 1 gang, plaster mounted bracket2155P2 2 gang, vertical, plaster mounted bracket2155P3 3 gang, vertical, plaster mounted bracket2155P4 4 gang, vertical, plaster mounted bracket2155PH2 2 gang, horizontal, plaster mounted bracket2155PH3 3 gang, horizontal, plaster mounted bracket

Electrical AccessoriesSOCKET OUTLETS2015V Single gang power outlet, vertical, 250V, 10A2015 Single gang power outlet, horizontal, 250V, 10A2025V Double gang power outlet, vertical, 250V, 10A2025 Double gang power outlet, horizontal, 250V, 10ASWITCHES2031VA 1 gang, vertical, switch, 250V, 10A2032VA 2 gang, vertical, switch, 250V, 10A2033VA 3 gang, vertical, switch, 250V, 10A2034VA 4 gang, vertical, switch, 250V, 10A2035VA 5 gang, vertical, switch, 250V, 10A2036VA 6 gang, vertical, switch, 250V, 10A2031HA 1 gang, horizontal, switch, 250V, 10A2032HA 2 gang, horizontal, switch, 250V, 10A2033HA 3 gang, horizontal, switch, 250V, 10A2034HA 4 gang, horizontal, switch, 250V, 10ADIMMERS2032E450L 1 gang light dimmer, incandescent, 250V, 450WPHONE & DATA2031VTO 1 gang telephone outlet plate, Telstra 610 type2031VRJ 1 gang data outlet, RJ45 Series socket mech.2032VRJ 2 gang data outlet, RJ45 series socket mech.

Technical Data

CATALOGUE NUMBER & DESCRIPTION

2033HA

2015V

2032VRJ

2032E450L

Page 17: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

OE

M A

CC

ES

SO

RIE

S2

00

0 S

eri

es

16

2000 SERIES

Medical Service Panels located within hospitals often

incorporate systems other than items found within

the Medilec ML2000 and Clipsal 2000 product range.

These additional systems include Nurse Call and Gas

Supply systems.

The advantage of the Clipsal 2000 Series format is that

it is a common platform on which other companies

develop their products. Therefore all of the systems

found on Medical Service Panels are available on the

2000 Series platform.

Detailed below is a list of some of the OEM suppliers of

2000 Series Accessories.

Nurse Call Systems

Austco Communications Systems

Inteltec Communications

MI-CAL Systems

Questek Australia

Gas Systems

Gascon Systems

OEM 2000 Series Accessories

Gascon Gas Outlet

Austco Nurse Call

Questek Nurse Call

MI-CAL Nurse Call

Page 18: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET
Page 19: 7396 Medilec ML2000 brochureupdates.clipsal.com/clipsalonlinenz/Files/Brochures/M... · 2008. 7. 14. · Introduction 2 - 3 Contents ML2000 Series • SOCKET OUTLETS 8 - 11 • SOCKET

A member of Clipsal Australia Holdings GroupABN 15 089 444 931

Head Offi ce12 Park Terrace, BowdenSouth Australia 5007PO Box 103 HindmarshSouth Australia 5007

Telephone (08) 8440 0500International +61 8 8440 0500

Facsimile (08) 8346 0845International +61 8 8346 0845

Internet www.clipsal.com/cisE-Mail [email protected]

CIS Technical Support Hotline1300 722 247

Offi ces in all States

NSW Sydney (02) 9794 9200 Albury (02) 6041 2377

VIC Melbourne (03) 9207 3200 Country Areas 1800 653 893

QLD Brisbane (07) 3244 7444 Townsville (07) 4729 3333

SA Adelaide (08) 8268 0400

WA Perth (08) 9442 4444

TAS Launceston (03) 6343 5900

NT Darwin (08) 8947 0278

International Enquiries

International Sales and MarketingTelephone +61 8 8269 0587Facsimile +61 8 8340 7350E-Mail [email protected]

New ZealandClipsal Industries (NZ) LtdTelephone +64 9 576 3403Facsimile +64 9 576 1015E-Mail headoffi [email protected] ServiceFree Facsimile (0508) 250 305Auckland/Mobile Phone (09) 572 0014Free Phone (0508) CLIPSAL 2547725

MalaysiaClipsal (M) Sdn BhdNo. 1, Jalan Kawat 15/18, Seksyen 15,40200 Shah Alam, SelangorTelephone +60 3 5519 1111Facsimile +60 3 5519 4378

SingaporeClipsal SingaporeNo. 5, Fourth Chin Bee RoadSingapore 619699Telephone +65 6 415 3288Facsimile +65 6 415 3289E-Mail [email protected]

International Representatives

ChinaClipsal China Ltd Telephone +86 755 8237 5959

Hong KongClipsal Integrated Systems (HK) Limited Telephone +852 2 487 0261

South AfricaClipsal South Africa (Pty) Ltd Telephone +27 11 314 5200

TaiwanClipsal (Taiwan) Co Ltd Telephone +886 2 2558 3456

ThailandClipsal Thailand Ltd Telephone +66 2 952 5338

United KingdomClipsal Integrated Systems (UK) Telephone +44 1628 508 530

O/N 17747 May 04/02

Clipsal Integrated Systems Pty Ltd reserves the right to change spec i fi ca tions, modify designs and dis con tin ue items without incurring obligation and whilst every ef-fort is made to ensure that descriptions, specifi cations and other in for ma tion in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein.

clipsal.com/cis

You can fi nd this brochure and many others online in PDF format at: clipsal.comFollow the links off the home page or access the following page directly: clipsal.com/wat_lib_pdf.cfm

©Copyright Clipsal Integrated Systems Pty Ltd 2001.All right reserved.

This material is copyright under Australian and international laws. Except as permitted under the relevant law, no part of this work may be reproduced by any process without prior written permission of and acknowledgement to Clipsal Integrated Systems Pty Ltd.

CLIPADV 7396

Products of Clipsal Integrated Sys tems Pty Ltd