72361703-smc-autoprovisioning

115
1 Storage Provisioning with EMC ® Symmetrix ® Autoprovisioning Groups Technical Notes P/N 300-009-148 REV A02 May 25, 2010 These technical notes contain information on the following topics: Executive summary ............................................................................................................................ 3 Introduction ......................................................................................................................................... 3 Audience ......................................................................................................................................................... 3 Conventions used in this document ........................................................................................................... 4 Provisioning storage using Solution Enabler ............................................................................... 4 Presenting storage to a SYMAPI control host............................................................................................ 4 Steps for provisioning storage ................................................................................................................ 5 Example of provisioning storage ............................................................................................................ 5 Presenting storage to a production and a backup host ............................................................................ 8 Steps for provisioning storage ................................................................................................................ 8 Example of provisioning storage ............................................................................................................ 9 Adding existing storage, ports, or initiators to an existing view ..................................................... 16 Example of adding storage to an existing storage group .................................................................. 16 Presenting storage to a cluster ................................................................................................................... 20 Steps for provisioning storage by using a cascaded initiator group ............................................... 21 Example of using a cascaded initiator group...................................................................................... 22 Removing a masking view and its associated groups ............................................................................ 30 Example of deleting a masking view and associated groups ........................................................... 31 Specifying LUN addresses ......................................................................................................................... 33 Specifying HBA flags .................................................................................................................................. 41 Overriding port flags .................................................................................................................................. 45 Insuring consistent LUNs across initiators .............................................................................................. 50 Provisioning storage using SMC ................................................................................................... 52 Presenting storage to a SYMAPI control host.......................................................................................... 52

Upload: kishore-kumar

Post on 24-Apr-2015

192 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: 72361703-smc-autoprovisioning

1

Storage Provisioning with EMC® Symmetrix®

Autoprovisioning Groups

Technical Notes P/N 300-009-148

REV A02 May 25, 2010

These technical notes contain information on the following topics:

Executive summary ............................................................................................................................ 3 Introduction ......................................................................................................................................... 3

Audience ......................................................................................................................................................... 3 Conventions used in this document ........................................................................................................... 4

Provisioning storage using Solution Enabler ............................................................................... 4 Presenting storage to a SYMAPI control host ............................................................................................ 4

Steps for provisioning storage ................................................................................................................ 5 Example of provisioning storage ............................................................................................................ 5

Presenting storage to a production and a backup host ............................................................................ 8 Steps for provisioning storage ................................................................................................................ 8 Example of provisioning storage ............................................................................................................ 9 Adding existing storage, ports, or initiators to an existing view ..................................................... 16 Example of adding storage to an existing storage group .................................................................. 16

Presenting storage to a cluster ................................................................................................................... 20 Steps for provisioning storage by using a cascaded initiator group ............................................... 21 Example of using a cascaded initiator group ...................................................................................... 22

Removing a masking view and its associated groups ............................................................................ 30 Example of deleting a masking view and associated groups ........................................................... 31

Specifying LUN addresses ......................................................................................................................... 33 Specifying HBA flags .................................................................................................................................. 41 Overriding port flags .................................................................................................................................. 45 Insuring consistent LUNs across initiators .............................................................................................. 50

Provisioning storage using SMC ................................................................................................... 52 Presenting storage to a SYMAPI control host .......................................................................................... 52

Page 2: 72361703-smc-autoprovisioning

2

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Steps for provisioning storage ............................................................................................................... 52 Example of provisioning storage .......................................................................................................... 53

Presenting storage to a production and a backup host ........................................................................... 61 Steps for provisioning storage ............................................................................................................... 61 Example of provisioning storage .......................................................................................................... 62 Adding existing storage, ports, or initiators to an existing view ...................................................... 76 Example of adding storage to an existing storage group .................................................................. 76

Presenting storage to a cluster .................................................................................................................... 80 Steps for provisioning storage using a cascaded initiator group ..................................................... 81 Example of using a cascaded initiator group ...................................................................................... 82

Removing a masking view and its associated groups ............................................................................ 92 Example of deleting a masking view and associated groups ............................................................ 93

Specifying LUN addresses .......................................................................................................................... 97 Specifying HBA flags ................................................................................................................................. 100 Overriding port flags ................................................................................................................................. 107 Insuring consistent LUNs across initiators ............................................................................................. 112

Conclusion ....................................................................................................................................... 113

Page 3: 72361703-smc-autoprovisioning

3

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Executive summary

Introduced in EMC® Solutions Enabler and EMC Symmetrix® Management Console (SMC) version 7.0, the Autoprovisioning Groups feature provides an easier, faster way to provision storage in EMC Symmetrix VMAX™ arrays running EMC Enginuity™ 5874. Most of the applications running on Symmetrix arrays require a fault-tolerant environment with clustered hosts as well as multiple paths to devices. Autoprovisioning Groups was developed to make storage allocation easier and faster, especially with these types of configurations.

Mapping and masking devices in previous versions of Solutions Enabler required a separate command for each initiator/port combination through which devices would be accessed. Both the symaccess command in Solutions Enabler and SMC allow the user to create a group of devices (storage group), a group of director ports (port group), and a group of host initiators (initiator group), and associate them in a masking view. When the masking view is created, the devices are automatically mapped and masked.

After the masking view is created, any objects (devices, ports, or initiators) added to an existing group automatically become part of the associated masking view. This means that no additional steps are necessary to add additional devices, ports, or initiators to an existing configuration. All necessary operations to make them part of the configuration are handled automatically by Symmetrix Enginuity once the objects are added to the applicable group. This reduces the number of commands needed for mapping and masking devices and allows for easier storage allocation and de-allocation.

Introduction

These technical notes describe how to provision storage by using the Symmetrix Autoprovisioning Groups feature. The goals of this paper are:

To summarize the functionality of the feature

To provide examples showing how to use Autoprovisioning Groups to provision storage

Audience

This document is intended for use by the technology professional who works in an environment with Symmetrix VMAX disk arrays. It is

Page 4: 72361703-smc-autoprovisioning

4

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

specifically targeted at EMC field technical staff and EMC customers who need to understand how to provision storage to hosts attached to a VMAX disk array.

Conventions used in this document

An ellipsis (...) appearing on a line by itself indicates that unnecessary command output has been removed.

Command syntax, output, and examples appear in the Courier New font.

An asterisk (*) appearing in command output indicates that unnecessary command output has been removed from within a line.

Provisioning storage using Solution Enabler

Several use cases will be presented that illustrate various ways that Autoprovisioning Groups can be used to provide access to Symmetrix volumes using Solutions Enabler.

Note: The use case examples were developed by using the same hosts, therefore the initiator WWNs are the same in all of the use cases. A WWN can only belong to a single initiator group; however, initiator groups can be cascaded by placing them in other initiator groups.

Presenting storage to a SYMAPI control host

In the first example, gatekeepers need to be provisioned to a management host that will be monitoring and managing the Symmetrix using Solutions Enabler. Best practice for assigning gatekeepers to hosts specifies that gatekeeper device be assigned on only a single front-end path.

Page 5: 72361703-smc-autoprovisioning

5

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Figure 1 Creating individual paths to gatekeepers

Steps for provisioning storage

In a simple configuration it is possible to create a masking view for a single initiator on a single port with any number of devices using just one symaccess command.

The following are the general steps that can be followed to accomplish this goal:

1. Create a view and specify a view name, HBA WWN, front-end port, and Symmetrix volumes for the first path.

2. Create a view and specify a view name, HBA WWN, front-end port, and Symmetrix volumes for the second path.

Once the masking view has been created, the devices are available to the initiators on the storage ports. Host-specific commands can then be run to configure the devices to the operating system.

Example of provisioning storage

Step 1 - Create a view and specify a view name, HBA WWN, front-end port, and Symmetrix volumes for the first path. When using this method, the view is given a name by the user and that name is used for the initiator, port, and storage groups.

The symaccess list hba command can be used to print the HBA WWNs and the ports that they are zoned to:

# symaccess list hba

Page 6: 72361703-smc-autoprovisioning

6

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Identifier Physical Device Path Symmetrix ID Dir:P ---------------- -------------------------------- ------------ ----- 10000000c9767816 c3t5000097208139918d0s2 000192601254 07E:0 10000000c9767817 c4t5000097208139959d0s2 000192601254 07F:1

Gatekeepers 08F – 092 will be made available on the first path:

# symaccess create view -name mgmtGKpath0 -wwn 10000000c9767816 -dirport 7E:0 devs 08F:092 -sid 54

Step 2 - Create a view and specify a view name, HBA WWN, front-end port, and Symmetrix volumes for the second path.

Gatekeepers 093 – 096 will be made available on the second path:

# symaccess create view -name mgmtGKpath1 -wwn 10000000c9767817 -dirport 7F:1 devs 093:096 -sid 54

The devices are now available to the initiators on the storage ports. After the host configures the devices, they are available to the operating system on both paths:

# symaccess list view -sid 54 Symmetrix ID : 000192601254 Masking View Name Initiator Group Port Group Storage Group ------------------- ------------------- ------------------- ----------------- mgmtGKpath0 mgmtGKpath0 mgmtGKpath0 mgmtGKpath0 mgmtGKpath1 mgmtGKpath1 mgmtGKpath1 mgmtGKpath1 # syminq Device Product Device ---------------------------- -------------------------- --------------------- Name Type Vendor ID Rev Ser Num Cap (KB) ---------------------------- -------------------------- --------------------- /dev/rdsk/c3t50*8d0s2 GK EMC SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t50*8d1s2 GK EMC SYMMETRIX 5874 540008F000 5760 /dev/rdsk/c3t50*8d2s2 GK EMC SYMMETRIX 5874 5400090000 5760 /dev/rdsk/c3t50*8d3s2 GK EMC SYMMETRIX 5874 5400091000 5760 /dev/rdsk/c3t50*8d4s2 GK EMC SYMMETRIX 5874 5400092000 5760 /dev/rdsk/c4t50*9d0s2 GK EMC SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t50*9d1s2 GK EMC SYMMETRIX 5874 5400093000 5760 /dev/rdsk/c4t50*9d2s2 GK EMC SYMMETRIX 5874 5400094000 5760 /dev/rdsk/c4t50*9d3s2 GK EMC SYMMETRIX 5874 5400095000 5760 /dev/rdsk/c4t50*9d4s2 GK EMC SYMMETRIX 5874 5400096000 5760 # symcfg discover This operation may take up to a few minutes. Please be patient...

Page 7: 72361703-smc-autoprovisioning

7

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

# symaccess show view mgmtGKpath0 -sid 54 Symmetrix ID : 000192601254 Masking View Name : mgmtGKpath0 Initiator Group Name : mgmtGKpath0 Host Initiators { WWN : 10000000c9767816 } Port Group Name : mgmtGKpath0 Director Identification { FA-7E:0 } Storage Group Name : mgmtGKpath0 Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 008F 07E:0 c3t5000097208139918d1s* 1 5 0090 07E:0 c3t5000097208139918d2s* 2 5 0091 07E:0 c3t5000097208139918d3s* 3 5 0092 07E:0 c3t5000097208139918d4s* 4 5 # symaccess show view mgmtGKpath1 -sid 54 Symmetrix ID : 000192601254 Masking View Name : mgmtGKpath1 Initiator Group Name : mgmtGKpath1 Host Initiators { WWN : 10000000c9767817 } Port Group Name : mgmtGKpath1 Director Identification { FA-7F:1 } Storage Group Name : mgmtGKpath1 Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 0093 07F:1 c4t5000097208139959d1s* 1 5 0094 07F:1 c4t5000097208139959d2s* 2 5 0095 07F:1 c4t5000097208139959d3s* 3 5 0096 07F:1 c4t5000097208139959d4s* 4 5

Page 8: 72361703-smc-autoprovisioning

8

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Additional elements such as initiators, ports, or volumes can be added, as needed, to the groups that are created by the command.

Note: Running symcfg discover is not required; however, the Physical Device Name field in symaccess show view will display the devices as “Not Visible” until they are configured by the host and symcfg discover is run.

Presenting storage to a production and a backup host

This use case shows a simplified configuration in which the storage administrator needs to provision storage to two newly attached hosts. In this example, one of the machines is a production database server and the other is a database backup server that will access clones of the production volumes. Each host will access its own set of devices through two HBAs zoned to the VMAX array on the same FA ports.

Figure 2 Storage presented to a production and a backup host

Steps for provisioning storage

To make the storage available to the appropriate host, the storage groups, port group, and initiator groups must be created. The applicable groups must then be combined into a masking view for each host, which will do the mapping and masking so that the storage is accessible.

In this example a Symmetrix device group will be created and will be used to provide the device lists for the storage groups.

Page 9: 72361703-smc-autoprovisioning

9

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

The following are the general steps that can be followed to accomplish this goal:

1. Create a Symmetrix device group that contains the production volumes and the clone target volumes.

2. Create the production storage group that contains the production volumes.

3. Create the backup storage group that contains the clone target volumes.

4. Create the port group.

5. Create the production server initiator group.

6. Create the backup server initiator group.

7. Create the production server masking view containing the production storage group, port group, and production initiator group.

8. Create the backup server masking view containing the backup storage group, port group, and backup initiator group.

Once the masking view has been created, the devices are available to the initiators on the storage ports. Host-specific commands can then be run to configure the devices to the operating system.

Example of provisioning storage

Step 1 - Create a Symmetrix device group, add the production volumes, and add the clone target volumes:

# symdg create proddb_dg # symld -g proddb_dg addall dev -range 798:79B -sid 54 # symld -g proddb_dg addall dev -range 912:915 –tgt

The device group now contains the standard volumes (STD) for the production host and the target volumes (TGT) for the backup host:

# symdg show proddb_dg Group Name: proddb_dg Group Type : REGULAR Device Group in GNS : No Valid : Yes Symmetrix ID : 000192601254 Group Creation Time : Fri Jan 30 16:06:03 2009 Vendor ID : EMC Corp Application ID : SYMCLI

Page 10: 72361703-smc-autoprovisioning

10

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Number of STD Devices in Group : 4 Number of Associated GK's : 0 Number of Locally-associated BCV's : 0 Number of Locally-associated VDEV's : 0 Number of Locally-associated TGT's : 4 Number of Remotely-associated VDEV's(STD RDF): 0 Number of Remotely-associated BCV's (STD RDF): 0 Number of Remotely-associated TGT's(TGT RDF) : 0 Number of Remotely-associated BCV's (BCV RDF): 0 Number of Remotely-assoc'd RBCV's (RBCV RDF) : 0 Number of Remotely-assoc'd BCV's (Hop-2 BCV) : 0 Number of Remotely-assoc'd VDEV's(Hop-2 VDEV): 0 Number of Remotely-assoc'd TGT's (Hop-2 TGT) : 0 Standard (STD) Devices (4): { -------------------------------------------------------------------- Sym Cap LdevName PdevName Dev Att. Sts (MB) -------------------------------------------------------------------- DEV001 N/A 0798 RW 4314 DEV002 N/A 0799 RW 4314 DEV003 N/A 079A RW 4314 DEV004 N/A 079B RW 4314 } TGT Devices Locally-associated (4): { -------------------------------------------------------------------- Sym Cap LdevName PdevName Dev Att. Sts (MB) -------------------------------------------------------------------- TGT001 N/A 0912 RW 4314 TGT002 N/A 0913 RW 4314 TGT003 N/A 0914 RW 4314 TGT004 N/A 0915 RW 4314 }

Step 2 - Create the production storage group that contains the production volumes. For this step, the device group will be used to provide the device list for the symaccess command. The standard devices will be added to the group by default:

# symaccess create -name dbprod_stor -type storage -g proddb_dg -sid 54

Groups that have been created can be viewed using symaccess list and symaccess show commands:

# symaccess list -type storage -name dbprod_stor -sid 54 -v Symmetrix ID : 000192601254 Storage Group Name : dbprod_stor

Page 11: 72361703-smc-autoprovisioning

11

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Device Count : 4 Masking View Count : 0 Last updated at : 09:47:30 PM on Fri Jan 30,2009 # symaccess show dbprod_stor -type storage -sid 54 Symmetrix ID : 000192601254 Last updated at : 09:47:30 PM on Fri Jan 30,2009 Storage Group Name : dbprod_stor Devices : 0798:079B Masking View Names { None }

Step 3 - Create the backup storage group that contains the clone target volumes. For this step, the device group will be used with the –tgt flag to add the target devices:

# symaccess create -name dbbackup_stor -type storage -g proddb_dg -tgt -sid 54 # symaccess show dbbackup_stor -type storage -sid 54 Symmetrix ID : 000192601254 Last updated at : 10:48:42 PM on Fri Jan 30,2009 Storage Group Name : dbbackup_stor Devices : 0912:0915 Masking View Names { None }

Step 4 – Create the port group containing the two Symmetrix ports to which the HBAs are zoned:

# symaccess create -name dbsrv_port -type port -dirport 7E:0,7F:1 -sid 54 # symaccess show dbsrv_port -type port -sid 54 Symmetrix ID : 000192601254 Last updated at : 04:09:19 PM on Mon Feb 02,2009 Port Group Name : dbsrv_port Director Identification {

Page 12: 72361703-smc-autoprovisioning

12

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

FA-7E:0 FA-7F:1 } Masking View Names { None }

The –detail option can also be used with symaccess list to generate output with the port and view counts in columns:

# symaccess list -type port -name dbsrv_port -sid 54 -detail Symmetrix ID : 000192601254 Port View Port Group Name Count Count -------------------------------- ----- ----- dbsrv_port 2 0

Step 5 – Create the production server initiator group. In this example, the HBA WWNs are entered by using a file. They can also be entered manually on the command line.

Each WWN in the file must contain the string “WWN:” followed by the 16-digit WWN. It cannot contain blank spaces or empty lines:

# cat /prod_WWN_file WWN:10000000c9767816 WWN:10000000c9767817 # symaccess create -name dbprodsrv_init -type initiator -file /prod_WWN_file -sid 54 # symaccess show dbprodsrv_init -type initiator -sid 54 Symmetrix ID : 000192601254 Last updated at : 04:34:31 PM on Mon Feb 02,2009 Initiator Group Name : dbprodsrv_init Host Initiators { WWN :10000000c9767816 WWN :10000000c9767817 } Masking View Names { None }

Page 13: 72361703-smc-autoprovisioning

13

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Parent Initiator Groups { None }

Step 6 – Create the backup server initiator group:

# symaccess create -name dbbackupsrv_init -type initiator -file /backup_WWN_file -sid 54 # symaccess show dbbackupsrv_init -type initiator -sid 54 Symmetrix ID : 000192601254 Last updated at : 08:34:22 PM on Mon Feb 02,2009 Initiator Group Name : dbbackupsrv_init Host Initiators { WWN :10000000c97683e0 WWN :10000000c97683e1 } Masking View Names { None } Parent Initiator Groups { None }

Step 7 – Create the production server masking view containing the production storage group, port group, and production initiator group. Once the masking view command completes and the prompt returns, the devices will be mapped and masked and available to the production host:

# symaccess create view -name dbprodsrv_view -storgrp dbprod_stor -portgrp dbsrv_port –initgrp dbprodsrv_init –sid 54

The production masking view has now been created. Both symaccess list and symaccess show display the view along with its associated initiator group, port group, and storage group:

# symaccess list view -name dbprodsrv_view -sid 54 Symmetrix ID : 000192601254 Masking View Name Initiator Group Port Group Storage Group

Page 14: 72361703-smc-autoprovisioning

14

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

------------------- ------------------- ------------------- ------------------ dbprodsrv_view dbprodsrv_init dbsrv_port dbprod_stor # symaccess show view dbprodsrv_view -sid 54 Symmetrix ID : 000192601254 Masking View Name : dbprodsrv_view Initiator Group Name : dbprodsrv_init Host Initiators { WWN : 10000000c9767816 WWN : 10000000c9767817 } Port Group Name : dbsrv_port Director Identification { FA-7E:0 FA-7F:1 } Storage Group Name : dbprod_stor Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 0798 07E:0 Not Visible 1 4314 07F:1 Not Visible 1 4314 0799 07E:0 Not Visible 2 4314 07F:1 Not Visible 2 4314 079A 07E:0 Not Visible 3 4314 07F:1 Not Visible 3 4314 079B 07E:0 Not Visible 4 4314 07F:1 Not Visible 4 4314

After running the host-specific commands to configure new devices, the Symmetrix volumes in the storage group are available to the host:

# syminq Device Product Device ---------------------------- -------------------------- --------------------- Name Type Vendor ID Rev Ser Num Cap (KB) ---------------------------- -------------------------- --------------------- /dev/rdsk/c3t50*8d0s2 GK EMC SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t50*8d1s2 EMC SYMMETRIX 5874 5400798000 4417920 /dev/rdsk/c3t50*8d2s2 EMC SYMMETRIX 5874 5400799000 4417920 /dev/rdsk/c3t50*8d3s2 EMC SYMMETRIX 5874 540079A000 4417920 /dev/rdsk/c3t50*8d4s2 EMC SYMMETRIX 5874 540079B000 4417920 /dev/rdsk/c4t50*9d0s2 GK EMC SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t50*9d1s2 EMC SYMMETRIX 5874 5400798000 4417920 /dev/rdsk/c4t50*9d2s2 EMC SYMMETRIX 5874 5400799000 4417920

Page 15: 72361703-smc-autoprovisioning

15

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

/dev/rdsk/c4t50*9d3s2 EMC SYMMETRIX 5874 540079A000 4417920 /dev/rdsk/c4t50*9d4s2 EMC SYMMETRIX 5874 540079B000 4417920

Step 8 – Create the backup server masking view that contains the backup storage group, port group, and backup initiator group:

# symaccess create view -name dbbackupsrv_view -storgrp dbbackup_stor -portgrp dbsrv_port –initgrp dbbackupsrv_init –sid 54

The backup masking view has now been created. Both symaccess list and symaccess show display the view along with its associated initiator group, port group, and storage group:

# symaccess list view -name dbbackupsrv_view -sid 54 Symmetrix ID : 000192601254 Masking View Name Initiator Group Port Group Storage Group ------------------- ------------------- ------------------- ------------------ dbbackupsrv_view dbbackupsrv_init dbsrv_port dbbackup_stor # symaccess show view dbbackupsrv_view -sid 54 Symmetrix ID : 000192601254 Masking View Name : dbbackupsrv_view Initiator Group Name : dbbackupsrv_init Host Initiators { WWN : 10000000c97683e0 WWN : 10000000c97683e1 } Port Group Name : dbsrv_port Director Identification { FA-7E:0 FA-7F:1 } Storage Group Name : dbbackup_stor Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 0912 07E:0 Not Visible 1 4314 07F:1 Not Visible 1 4314 0913 07E:0 Not Visible 2 4314 07F:1 Not Visible 2 4314 0914 07E:0 Not Visible 3 4314 07F:1 Not Visible 3 4314 0915 07E:0 Not Visible 4 4314

Page 16: 72361703-smc-autoprovisioning

16

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

07F:1 Not Visible 4 4314

After running the host-specific commands to configure new devices, the Symmetrix volumes in the storage group are available to the host:

# syminq Device Product Device ---------------------------- -------------------------- --------------------- Name Type Vendor ID Rev Ser Num Cap (KB) ---------------------------- -------------------------- --------------------- /dev/rdsk/c3t50*8d0s2 GK EMC SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t50*8d1s2 EMC SYMMETRIX 5874 5400912000 4417920 /dev/rdsk/c3t50*8d2s2 EMC SYMMETRIX 5874 5400913000 4417920 /dev/rdsk/c3t50*8d3s2 EMC SYMMETRIX 5874 5400914000 4417920 /dev/rdsk/c3t50*8d4s2 EMC SYMMETRIX 5874 5400915000 4417920 /dev/rdsk/c4t50*9d0s2 GK EMC SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t50*9d1s2 EMC SYMMETRIX 5874 5400912000 4417920 /dev/rdsk/c4t50*9d2s2 EMC SYMMETRIX 5874 5400913000 4417920 /dev/rdsk/c4t50*9d3s2 EMC SYMMETRIX 5874 5400914000 4417920 /dev/rdsk/c4t50*9d4s2 EMC SYMMETRIX 5874 5400915000 4417920

Adding existing storage, ports, or initiators to an existing view

Adding additional Symmetrix volumes, array ports, or host initiators to the existing masking view is as simple as adding the desired element to an existing storage, port, or initiator group.

If the production environment in the previous example is running out of space and needs more storage, the following steps can be followed to make additional Symmetrix volumes available to the production host with corresponding target devices available to the backup host. As in the original example, the Symmetrix device group is used to provide the device lists for the symaccess commands:

1. Add the standard devices to the device group.

2. Add the target devices to the device group

3. Run the symaccess add command to add the standard devices that were placed in the device group into the production storage group.

4. Run the symaccess add command to add the target devices that were placed in the device group into the backup storage group.

Example of adding storage to an existing storage group

Step 1 - Add standard devices 7C3 and 7C4 to the device group.

# symld -g proddb_dg addall dev -range 7C3:7C4

Page 17: 72361703-smc-autoprovisioning

17

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Step 2 - Add target devices 916 and 917 to the device group.

# symld -g proddb_dg addall dev -range 916:917 -tgt # symdg show proddb_dg Group Name: proddb_dg Group Type : REGULAR Device Group in GNS : No Valid : Yes Symmetrix ID : 000192601254 Group Creation Time : Fri Jan 30 16:06:03 2009 Vendor ID : EMC Corp Application ID : SYMCLI Number of STD Devices in Group : 6 Number of Associated GK's : 0 Number of Locally-associated BCV's : 0 Number of Locally-associated VDEV's : 0 Number of Locally-associated TGT's : 6 Number of Remotely-associated VDEV's(STD RDF): 0 Number of Remotely-associated BCV's (STD RDF): 0 Number of Remotely-associated TGT's(TGT RDF) : 0 Number of Remotely-associated BCV's (BCV RDF): 0 Number of Remotely-assoc'd RBCV's (RBCV RDF) : 0 Number of Remotely-assoc'd BCV's (Hop-2 BCV) : 0 Number of Remotely-assoc'd VDEV's(Hop-2 VDEV): 0 Number of Remotely-assoc'd TGT's (Hop-2 TGT) : 0 Standard (STD) Devices (6): { -------------------------------------------------------------------- Sym Cap LdevName PdevName Dev Att. Sts (MB) -------------------------------------------------------------------- DEV001 c3t5000097208139918d1s* 0798 RW 4314 DEV002 c3t5000097208139918d2s* 0799 RW 4314 DEV003 c3t5000097208139918d3s* 079A RW 4314 DEV004 c3t5000097208139918d4s* 079B RW 4314 DEV005 N/A 07C3 RW 4314 DEV006 N/A 07C4 RW 4314 } TGT Devices Locally-associated (6): { -------------------------------------------------------------------- Sym Cap LdevName PdevName Dev Att. Sts (MB) -------------------------------------------------------------------- TGT001 N/A 0912 RW 4314 TGT002 N/A 0913 RW 4314 TGT003 N/A 0914 RW 4314 TGT004 N/A 0915 RW 4314 TGT005 N/A 0916 RW 4314 TGT006 N/A 0917 RW 4314

Page 18: 72361703-smc-autoprovisioning

18

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

}

Step 3 – Run the symaccess add command to add the standard devices that were placed in the device group into the production storage group:

# symaccess add -name dbprod_stor -type storage -std -g proddb_dg -sid 54 # symaccess show view dbprodsrv_view -sid 54 Symmetrix ID : 000192601254 Masking View Name : dbprodsrv_view Initiator Group Name : dbprodsrv_init Host Initiators { WWN : 10000000c9767816 WWN : 10000000c9767817 } Port Group Name : dbsrv_port Director Identification { FA-7E:0 FA-7F:1 } Storage Group Name : dbprod_stor Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 0798 07E:0 c3t5000097208139918d1s* 1 4314 07F:1 c4t5000097208139959d1s* 1 4314 0799 07E:0 c3t5000097208139918d2s* 2 4314 07F:1 c4t5000097208139959d2s* 2 4314 079A 07E:0 c3t5000097208139918d3s* 3 4314 07F:1 c4t5000097208139959d3s* 3 4314 079B 07E:0 c3t5000097208139918d4s* 4 4314 07F:1 c4t5000097208139959d4s* 4 4314 07C3 07E:0 Not Visible 5 4314 07F:1 Not Visible 5 4314 07C4 07E:0 Not Visible 6 4314 07F:1 Not Visible 6 4314

Note: The new devices will be listed as “N/A” in the PdevName field in symdg show output and “Not Visible” in the symaccess show view output until they are configured by the host and symcfg discover is run.

Step 4 – Run the symaccess add command to add the target devices that were placed in the device group into the backup storage group:

Page 19: 72361703-smc-autoprovisioning

19

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

# symaccess add -name dbbackup_stor -type storage -tgt -g proddb_dg -sid 54 # symaccess show view dbbackupsrv_view -sid 54 Symmetrix ID : 000192601254 Masking View Name : dbbackupsrv_view Initiator Group Name : dbbackupsrv_init Host Initiators { WWN : 10000000c97683e0 WWN : 10000000c97683e1 } Port Group Name : dbsrv_port Director Identification { FA-7E:0 FA-7F:1 } Storage Group Name : dbbackup_stor Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 0912 07E:0 Not Visible 1 4314 07F:1 Not Visible 1 4314 0913 07E:0 Not Visible 2 4314 07F:1 Not Visible 2 4314 0914 07E:0 Not Visible 3 4314 07F:1 Not Visible 3 4314 0915 07E:0 Not Visible 4 4314 07F:1 Not Visible 4 4314 0916 07E:0 Not Visible 5 4314 07F:1 Not Visible 5 4314 0917 07E:0 Not Visible 6 4314 07F:1 Not Visible 6 4314

After running the applicable host commands, standard devices 7C3 and 7C4 are available to the production host and target devices 916 and 917 are available to the backup host:

# syminq Device Product Device ---------------------------- -------------------------- --------------------- Name Type Vendor ID Rev Ser Num Cap (KB) ---------------------------- -------------------------- --------------------- /dev/rdsk/c3t50*8d0s2 GK EMC SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t50*8d1s2 EMC SYMMETRIX 5874 5400798000 4417920 /dev/rdsk/c3t50*8d2s2 EMC SYMMETRIX 5874 5400799000 4417920 /dev/rdsk/c3t50*8d3s2 EMC SYMMETRIX 5874 540079A000 4417920 /dev/rdsk/c3t50*8d4s2 EMC SYMMETRIX 5874 540079B000 4417920

Page 20: 72361703-smc-autoprovisioning

20

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

/dev/rdsk/c3t50*8d5s2 EMC SYMMETRIX 5874 54007C3000 4417920 /dev/rdsk/c3t50*8d6s2 EMC SYMMETRIX 5874 54007C4000 4417920 /dev/rdsk/c4t50*9d0s2 GK EMC SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t50*9d1s2 EMC SYMMETRIX 5874 5400798000 4417920 /dev/rdsk/c4t50*9d2s2 EMC SYMMETRIX 5874 5400799000 4417920 /dev/rdsk/c4t50*9d3s2 EMC SYMMETRIX 5874 540079A000 4417920 /dev/rdsk/c4t50*9d4s2 EMC SYMMETRIX 5874 540079B000 4417920 /dev/rdsk/c4t50*9d5s2 EMC SYMMETRIX 5874 54007C3000 4417920 /dev/rdsk/c4t50*9d6s2 EMC SYMMETRIX 5874 54007C4000 4417920 # syminq Device Product Device ---------------------------- -------------------------- --------------------- Name Type Vendor ID Rev Ser Num Cap (KB) ---------------------------- -------------------------- --------------------- /dev/rdsk/c3t50*8d0s2 GK EMC SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t50*8d1s2 EMC SYMMETRIX 5874 5400912000 4417920 /dev/rdsk/c3t50*8d2s2 EMC SYMMETRIX 5874 5400913000 4417920 /dev/rdsk/c3t50*8d3s2 EMC SYMMETRIX 5874 5400914000 4417920 /dev/rdsk/c3t50*8d4s2 EMC SYMMETRIX 5874 5400915000 4417920 /dev/rdsk/c3t50*8d5s2 EMC SYMMETRIX 5874 5400916000 4417920 /dev/rdsk/c3t50*8d6s2 EMC SYMMETRIX 5874 5400917000 4417920 /dev/rdsk/c4t50*9d0s2 GK EMC SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t50*9d1s2 EMC SYMMETRIX 5874 5400912000 4417920 /dev/rdsk/c4t50*9d2s2 EMC SYMMETRIX 5874 5400913000 4417920 /dev/rdsk/c4t50*9d3s2 EMC SYMMETRIX 5874 5400914000 4417920 /dev/rdsk/c4t50*9d4s2 EMC SYMMETRIX 5874 5400915000 4417920 /dev/rdsk/c4t50*9d5s2 EMC SYMMETRIX 5874 5400916000 4417920 /dev/rdsk/c4t50*9d6s2 EMC SYMMETRIX 5874 5400917000 4417920

Presenting storage to a cluster

Cascaded initiator groups can be used to assign shared volumes to cluster nodes while still assigning groups of devices that are not shared among the hosts.

This use case shows a simplified configuration in which the storage administrator needs to provision storage two newly attached cluster nodes. In this example, both nodes of the cluster will share four EMC Virtual ProvisioningTM thin devices (92A – 92D). Each node will also have access to two RAID 6 devices (7DB – 7DC for node A and 7DD – 7DE for node B) that will not be available to the other host.

Page 21: 72361703-smc-autoprovisioning

21

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Figure 3 Storage presented in a clustered environment

Steps for provisioning storage using a cascaded initiator group

In this example, no Symmetrix device groups will be created. Both a device file and command line ranges will be used for the device lists.

1. Create a storage group containing the volumes that will be presented to Node A only.

2. Create a storage group containing the volumes that will be presented to Node B only.

3. Create the port group.

4. Create the initiator group for Node A.

5. Create the initiator group for Node B.

6. Create the cascaded initiator group and add the initiator group for Node A to the cascaded initiator group.

7. Add the initiator group for Node B to the cascaded initiator group.

8. Create the clustered device masking view containing the shared storage group, the port group, and the cascaded initiator group.

9. Create the Node A masking view containing the Node A storage

Page 22: 72361703-smc-autoprovisioning

22

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

group, port group, and Node A initiator group.

10. Create the Node B masking view containing the Node B storage group, port group, and Node B initiator group.

After running the host commands to configure the new devices, they are available to the operating system.

Example of using a cascaded initiator group

Step 1 — Create a storage group that contains the volumes (92A – 92D) that will be shared among both nodes of the cluster. In this example, the device list is provided in a device file:

# cat devs 92A 92B 92C 92D # symaccess create -name clustnodeAB_stor -type storage -file devs -sid 54 # symaccess show clustnodeAB_stor -type storage -sid 54 Symmetrix ID : 000192601254 Last updated at : 02:17:57 PM on Wed Apr 08,2009 Storage Group Name : clustnodeAB_stor Devices : 092A:092D Masking View Names { None }

Step 2 — Create a storage group that contains the volumes that will be presented to Node A only (7DB:7DC). The devices to be added will be specified in the CLI command:

# symaccess create -name clustnodeA_stor -type storage devs 7DB:7DC -sid 54 # symaccess show clustnodeA_stor -type storage -sid 54 Symmetrix ID : 000192601254 Last updated at : 02:18:48 PM on Wed Apr 08,2009 Storage Group Name : clustnodeA_stor Devices : 07DB:07DC Masking View Names

Page 23: 72361703-smc-autoprovisioning

23

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

{ None }

Step 3 — Create a storage group that contains the volumes that will be presented to Node B only (7DD:7DE). The devices to be added will be specified in the CLI command:

# symaccess create -name clustnodeB_stor -type storage devs 7DD:7DE -sid 54 # symaccess show clustnodeB_stor -type storage -sid 54 Symmetrix ID : 000192601254 Last updated at : 02:19:23 PM on Wed Apr 08,2009 Storage Group Name : clustnodeB_stor Devices : 07DD:07DE Masking View Names { None }

Step 4 — Create the port group:

# symaccess create -name clust_port -type port -dirport 07E:0,07F:1 -sid 54 # symaccess show clust_port -type port -sid 54 Symmetrix ID : 000192601254 Last updated at : 02:19:50 PM on Wed Apr 08,2009 Port Group Name : clust_port Director Identification { FA-7E:0 FA-7F:1 } Masking View Names { None }

Step 5 — Create the initiator group for Node A:

# cat clustnodeA_WWN_file WWN:10000000c9767816 WWN:10000000c9767817

Page 24: 72361703-smc-autoprovisioning

24

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

# symaccess create -name clustnodeA_init -type initiator -file clustnodeA_WWN_file -sid 54 # symaccess show clustnodeA_init -type initiator -sid 54 Symmetrix ID : 000192601254 Last updated at : 02:31:15 PM on Wed Apr 08,2009 Initiator Group Name : clustnodeA_init Host Initiators { WWN :10000000c9767816 WWN :10000000c9767817 } Masking View Names { None } Parent Initiator Groups { None }

Create a storage group that contains the volumes that — Create the initiator group for Node B:

# cat clustnodeB_WWN_file WWN:10000000c97683e0 WWN:10000000c97683e1 # symaccess create -name clustnodeB_init -type initiator -file clustnodeB_WWN_file -sid 54 # symaccess show clustnodeB_init -type initiator -sid 54 Symmetrix ID : 000192601254 Last updated at : 02:32:45 PM on Wed Apr 08,2009 Initiator Group Name : clustnodeB_init Host Initiators { WWN :10000000c97683e0 WWN :10000000c97683e1 } Masking View Names { None }

Page 25: 72361703-smc-autoprovisioning

25

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Parent Initiator Groups { None }

Step 7 — Create the cascaded initiator group:

One of the existing initiator groups, in this case, clustnodeA,_init is added when the cascaded IG is created:

# symaccess create -name clustnodeAB_init -type initiator -ig clustnodeA_init -sid 54

Step 8 — Add the initiator group for Node B to the cascaded initiator group:

# symaccess add -name clustnodeAB_init -type initiator -ig clustnodeB_init -sid 54 # symaccess show clustnodeAB_init -type initiator -sid 54 Symmetrix ID : 000192601254 Last updated at : 02:34:03 PM on Wed Apr 08,2009 Initiator Group Name : clustnodeAB_init Host Initiators { IG :clustnodeA_init IG :clustnodeB_init } Masking View Names { None } Parent Initiator Groups { None }

Step 9 — Create the clustered device masking view containing the shared storage group, the port group, and the cascaded initiator group:

# symaccess create view -name clustnodeAB_view -storgrp clustnodeAB_stor -portgrp clust_port -initgrp clustnodeAB_init -sid 54

Running symaccess show view on the cascaded initiator group will display the child initiator groups in the Host Initiators field:

# symaccess show view clustnodeAB_view -sid 54

Page 26: 72361703-smc-autoprovisioning

26

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Symmetrix ID : 000192601254 Last updated at : 02:35:17 PM on Wed Apr 08,2009 Masking View Name : clustnodeAB_view Initiator Group Name : clustnodeAB_init Host Initiators { IG : clustnodeA_init IG : clustnodeB_init } Port Group Name : clust_port Director Identification { FA-7E:0 FA-7F:1 } Storage Group Name : clustnodeAB_stor Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 092A 07E:0 Not Visible 1 4314 07F:1 Not Visible 1 4314 092B 07E:0 Not Visible 2 4314 07F:1 Not Visible 2 4314 092C 07E:0 Not Visible 3 4314 07F:1 Not Visible 3 4314 092D 07E:0 Not Visible 4 4314 07F:1 Not Visible 4 4314

The -ig <child_ig> option can be chosen to see the cascaded group from the child group’s perspective:

# symaccess show view clustnodeAB_view -ig clustnodeA_init -sid 54 Symmetrix ID : 000192601254 Last updated at : 02:35:17 PM on Wed Apr 08,2009 Masking View Name : clustnodeAB_view Initiator Group Name : clustnodeA_init * Host Initiators { WWN : 10000000c9767816 WWN : 10000000c9767817 }

Page 27: 72361703-smc-autoprovisioning

27

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Port Group Name : clust_port Director Identification { FA-7E:0 FA-7F:1 } Storage Group Name : clustnodeAB_stor Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 092A 07E:0 Not Visible 1 4314 07F:1 Not Visible 1 4314 092B 07E:0 Not Visible 2 4314 07F:1 Not Visible 2 4314 092C 07E:0 Not Visible 3 4314 07F:1 Not Visible 3 4314 092D 07E:0 Not Visible 4 4314 07F:1 Not Visible 4 4314 * Denotes a cascaded Initiator Group within the specified Masking View # symaccess show view clustnodeAB_view -ig clustnodeB_init -sid 54 Symmetrix ID : 000192601254 Last updated at : 02:35:17 PM on Wed Apr 08,2009 Masking View Name : clustnodeAB_view Initiator Group Name : clustnodeB_init * Host Initiators { WWN : 10000000c97683e0 WWN : 10000000c97683e1 } Port Group Name : clust_port Director Identification { FA-7E:0 FA-7F:1 } Storage Group Name : clustnodeAB_stor Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 092A 07E:0 Not Visible 1 4314 07F:1 Not Visible 1 4314

Page 28: 72361703-smc-autoprovisioning

28

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

092B 07E:0 Not Visible 2 4314 07F:1 Not Visible 2 4314 092C 07E:0 Not Visible 3 4314 07F:1 Not Visible 3 4314 092D 07E:0 Not Visible 4 4314 07F:1 Not Visible 4 4314 * Denotes a cascaded Initiator Group within the specified Masking View

Step 10 — Create the Node A masking view containing the Node A storage group, the port group, and the Node A initiator group:

# symaccess create view -name clustnodeA_view -storgrp clustnodeA_stor -portgrp clust_port -initgrp clustnodeA_init -sid 54 # symaccess show view clustnodeA_view -sid 54 Symmetrix ID : 000192601254 Last updated at : 02:36:02 PM on Wed Apr 08,2009 Masking View Name : clustnodeA_view Initiator Group Name : clustnodeA_init Host Initiators { WWN : 10000000c9767816 WWN : 10000000c9767817 } Port Group Name : clust_port Director Identification { FA-7E:0 FA-7F:1 } Storage Group Name : clustnodeA_stor Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 07DB 07E:0 Not Visible 5 4314 07F:1 Not Visible 5 4314 07DC 07E:0 Not Visible 6 4314 07F:1 Not Visible 6 4314

Step 11 — Create the Node B masking view containing the Node B storage group, the port group, and the Node B initiator group:

# symaccess create view -name clustnodeB_view -storgrp clustnodeB_stor -portgrp clust_port -initgrp clustnodeB_init -sid 54

Page 29: 72361703-smc-autoprovisioning

29

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

# symaccess show view clustnodeB_view -sid 54 Symmetrix ID : 000192601254 Last updated at : 02:37:05 PM on Wed Apr 08,2009 Masking View Name : clustnodeB_view Initiator Group Name : clustnodeB_init Host Initiators { WWN : 10000000c97683e0 WWN : 10000000c97683e1 } Port Group Name : clust_port Director Identification { FA-7E:0 FA-7F:1 } Storage Group Name : clustnodeB_stor Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 07DD 07E:0 Not Visible 5 4314 07F:1 Not Visible 5 4314 07DE 07E:0 Not Visible 6 4314 07F:1 Not Visible 6 4314

After configuring the devices from the operating systems, the correct devices are available to each cluster node:

Cluster Node A sees thin devices 92A – 92D as well as RAID-6 devices 7DB – 7DC:

# syminq -sym Device Product Device ---------------------------------- --------------------- --------------------- Name Type ID Rev Ser Num Cap (KB) ---------------------------------- --------------------- --------------------- /dev/rdsk/c3t5000097*18d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t5000097*18d1s2 SYMMETRIX 5874 540092A000 4417920 /dev/rdsk/c3t5000097*18d2s2 SYMMETRIX 5874 540092B000 4417920 /dev/rdsk/c3t5000097*18d3s2 SYMMETRIX 5874 540092C000 4417920 /dev/rdsk/c3t5000097*18d4s2 SYMMETRIX 5874 540092D000 4417920 /dev/rdsk/c3t5000097*18d5s2 SYMMETRIX 5874 54007DB000 4417920 /dev/rdsk/c3t5000097*18d6s2 SYMMETRIX 5874 54007DC000 4417920 /dev/rdsk/c4t5000097*59d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t5000097*59d1s2 SYMMETRIX 5874 540092A000 4417920 /dev/rdsk/c4t5000097*59d2s2 SYMMETRIX 5874 540092B000 4417920

Page 30: 72361703-smc-autoprovisioning

30

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

/dev/rdsk/c4t5000097*59d3s2 SYMMETRIX 5874 540092C000 4417920 /dev/rdsk/c4t5000097*59d4s2 SYMMETRIX 5874 540092D000 4417920 /dev/rdsk/c4t5000097*59d5s2 SYMMETRIX 5874 54007DB000 4417920 /dev/rdsk/c4t5000097*59d6s2 SYMMETRIX 5874 54007DC000 4417920

Cluster Node B also sees thin devices 92A – 92D, but it sees RAID-6 devices 7DD – 7DE:

# syminq -sym Device Product Device ---------------------------------- --------------------- --------------------- Name Type ID Rev Ser Num Cap (KB) ---------------------------------- --------------------- --------------------- /dev/rdsk/c3t5000097*18d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t5000097*18d1s2 SYMMETRIX 5874 540092A000 4417920 /dev/rdsk/c3t5000097*18d2s2 SYMMETRIX 5874 540092B000 4417920 /dev/rdsk/c3t5000097*18d3s2 SYMMETRIX 5874 540092C000 4417920 /dev/rdsk/c3t5000097*18d4s2 SYMMETRIX 5874 540092D000 4417920 /dev/rdsk/c3t5000097*18d5s2 SYMMETRIX 5874 54007DD000 4417920 /dev/rdsk/c3t5000097*18d6s2 SYMMETRIX 5874 54007DE000 4417920 /dev/rdsk/c4t5000097*59d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t5000097*59d1s2 SYMMETRIX 5874 540092A000 4417920 /dev/rdsk/c4t5000097*59d2s2 SYMMETRIX 5874 540092B000 4417920 /dev/rdsk/c4t5000097*59d3s2 SYMMETRIX 5874 540092C000 4417920 /dev/rdsk/c4t5000097*59d4s2 SYMMETRIX 5874 540092D000 4417920 /dev/rdsk/c4t5000097*59d5s2 SYMMETRIX 5874 54007DD000 4417920 /dev/rdsk/c4t5000097*59d6s2 SYMMETRIX 5874 54007DE000 4417920

Note: The order in which the parent and child initiator groups are created will have an effect on what LUNs are assigned to the devices in the groups. If the order used in this example was reversed, meaning that the views for the child groups were created before the view for the parent group, the LUNs of the devices would be different.

For example, if clustnodeA_view and clustnodeB_view were created before clustnodeAB_view, devices 7DB-7DC would have LUNs 001-002, devices 7DD-7DE would also have LUNs 001-002, and devices 92A-92D in the parent initiator group would have LUNs 003-006.

Removing a masking view and its associated groups

Prior to removing storage, initiator, or port groups, any masking view to which the group is associated must first be removed. This will unmask the devices. The user also has the option to unmap the devices while removing the masking view.

The following steps can be performed to remove the masking view as well as the associated storage, initiator, and port groups:

Page 31: 72361703-smc-autoprovisioning

31

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

1. Delete the masking view and, optionally, unmap the devices in the associated storage group.

2. Delete the initiator group.

3. Delete the port group.

4. Delete the storage group.

Example of deleting a masking view and associated groups

In the following example, the proddb_view masking view will be deleted and the devices in the associated storage group will be unmapped. Following that, the initiator group, port group, and storage group will also be removed:

# symaccess show view proddb_view -sid 54 Symmetrix ID : 000192601254 Masking View Name : proddb_view Initiator Group Name : proddb_init Host Initiators { WWN : 10000000c97683e0 WWN : 10000000c97683e1 } Port Group Name : proddb_port Director Identification { FA-7E:0 FA-7F:1 } Storage Group Name : proddb_stor Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 07B0 07E:0 Not Visible 0 4314 07F:1 Not Visible 0 4314 07B1 07E:0 Not Visible 1 4314 07F:1 Not Visible 1 4314 07B2 07E:0 Not Visible 2 4314 07F:1 Not Visible 2 4314 07B3 07E:0 Not Visible 3 4314 07F:1 Not Visible 3 4314 00A8 07E:0 Not Visible 4 5 07F:1 Not Visible 4 5 00A9 07E:0 Not Visible 5 5 07F:1 Not Visible 5 5 00AA 07E:0 Not Visible 6 5

Page 32: 72361703-smc-autoprovisioning

32

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

07F:1 Not Visible 6 5 00AB 07E:0 Not Visible 7 5 07F:1 Not Visible 7 5

Step 1 – Delete the masking view and, optionally, unmap the devices in the associated storage group by using the –unmap option:

# symaccess delete view -name proddb_view -sid 54 -unmap –nop

When the prompt returns, the view has been deleted and the devices in the storage group have been ummapped from the FA ports:

# symaccess show view proddb_view -sid 54 No Masking Views could be found for the specified input parameters # symdev list -sid 54 -noport Symmetrix ID: 000192601254 Device Name Directors Device -------------------------- ------------- ------------------------------------- Cap Sym Physical SA :P DA :IT Config Attribute Sts (MB) -------------------------- ------------- ------------------------------------- ... 00A8 Not Visible ???:? 09A:D3 2-Way Mir N/Grp'd RW 6 00A9 Not Visible ???:? 09C:C2 2-Way Mir N/Grp'd RW 6 00AA Not Visible ???:? 09B:D4 2-Way Mir N/Grp'd RW 6 00AB Not Visible ???:? 10D:C0 2-Way Mir N/Grp'd RW 6 ... 07B0 Not Visible ???:? 10A:DA RAID-5 N/Grp'd RW 4314 07B1 Not Visible ???:? 10D:D9 RAID-5 N/Grp'd RW 4314 07B2 Not Visible ???:? 10C:DA RAID-5 N/Grp'd RW 4314 07B3 Not Visible ???:? 09A:D5 RAID-5 N/Grp'd RW 4314 ...

Step 2 – Delete the initiator group. If the initiator group is not empty, the initiators must be removed from the group prior to the delete or the –force flag must be used:

# symaccess delete -name proddb_init -type initiator -sid 54 -force –nop

Step 3 – Delete the port group. If the port group is not empty, the ports must be removed from the group prior to the delete or the –force flag must be used:

# symaccess delete -name proddb_port -type port -sid 54 -force –nop

Page 33: 72361703-smc-autoprovisioning

33

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Step 4 – Delete the storage group. If the storage group is not empty, the volumes must be removed from the group prior to deleting the group or the –force flag must be used:

# symaccess delete -name proddb_stor -type storage -sid 54 -force –nop

The view and groups have now been removed:

# symaccess list view -sid 54 Symmetrix ID : 000192601254 Masking View Name Initiator Group Port Group Storage Group ------------------ ------------------- ------------------- ------------------- view_LICOA067 init_LICOA067 port_LICOA067 stor_LICOA067 ctrlsrv_licoa068 ctrlsrv_licoa068 ctrlsrv_licoa068 ctrlsrv_licoa068 licoa057_1_view licoa057_1_hbas licoa057_1_ports licoa057_1_stor # symaccess list -sid 54 -detail Symmetrix ID : 000192601254 View Group Name Count Count Type -------------------------------- ----- ----- --------- init_LICOA067 2 3 Initiator licoa057_1_hbas 2 1 Initiator ctrlsrv_licoa068 2 1 Initiator port_LICOA067 2 3 Port licoa057_1_ports 2 1 Port ctrlsrv_licoa068 2 1 Port stor_LICOA067 8 1 Storage licoa057_1_stor 24 1 Storage ctrlsrv_licoa068 12 1 Storage

Specifying LUN addresses

The symaccess command assigns dynamic LUNs when device masking is performed. When the devices are mapped to the FA as part of the masking view creation, Symmetrix Enginuity assigns the next available LUNs to the devices in the storage group. If the –lun option is used when the masking view is created, the devices will be given a dynamic LUN range that starts at the specified value.

The following example shows a masking view being created for an existing initiator group, storage group, and port group.

The host initially sees only the ACLX database device:

# syminq -sym

Page 34: 72361703-smc-autoprovisioning

34

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Device Product Device ---------------------------------- --------------------- --------------------- Name Type ID Rev Ser Num Cap (KB) ---------------------------------- --------------------- --------------------- /dev/rdsk/c3t5000097*18d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t5000097*19d0s2 GK SYMMETRIX 5874 5400054000 5760

An initiator group, storage group, and port group have already been created for the host:

# symaccess list -sid 54 -detail Symmetrix ID : 000192601254 View Group Name Count Count Type -------------------------------- ----- ----- --------- proddb_init 2 0 Initiator proddb_port 2 0 Port proddb_stor 4 0 Storage # symaccess show proddb_init -type initiator -sid 54 Symmetrix ID : 000192601254 Last updated at : 08:35:04 PM on Thu Feb 12,2009 Initiator Group Name : proddb_init Host Initiators { WWN :10000000c97683e0 WWN :10000000c97683e1 } Masking View Names { None } # symaccess show proddb_stor -type storage -sid 54 Symmetrix ID : 000192601254 Last updated at : 08:38:14 PM on Thu Feb 12,2009 Storage Group Name : proddb_stor Devices : 07B0:07B3 Masking View Names { None } # symaccess show proddb_port -type port -sid 54

Page 35: 72361703-smc-autoprovisioning

35

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Symmetrix ID : 000192601254 Last updated at : 08:36:51 PM on Thu Feb 12,2009 Port Group Name : proddb_port Director Identification { FA-7E:0 FA-7F:1 } Masking View Names { None }

A masking view can now be created that will mask and map the four devices in the storage group (7B0 - 7B3) on the ports in the port group to the WWNs in the initiator group. When the mapping is done, the devices in the storage group will get the next four LUNs available on the FA port. By specifying a starting LUN value, in this case LUN 1, the LUN values will be assigned dynamically:

# symaccess create view -name proddb_view -storgrp proddb_stor -portgrp proddb_port –initgrp proddb_init -lun 1 -sid 54

Because mapping is also being done, the prompt will take a few moments to return. After the command completes, the devices are mapped and masked and available to be configured by the host operating system. The devices have been dynamically assigned LUNs 001 – 004, which are displayed in the Host LUN column of the storage group:

# symaccess show view proddb_view -sid 54 Symmetrix ID : 000192601254 Masking View Name : proddb_view Initiator Group Name : proddb_init Host Initiators { WWN : 10000000c97683e0 WWN : 10000000c97683e1 } Port Group Name : proddb_port Director Identification {

Page 36: 72361703-smc-autoprovisioning

36

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

FA-7E:0 FA-7F:1 } Storage Group Name : proddb_stor Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 07B0 07E:0 Not Visible 1 4314 07F:1 Not Visible 1 4314 07B1 07E:0 Not Visible 2 4314 07F:1 Not Visible 2 4314 07B2 07E:0 Not Visible 3 4314 07F:1 Not Visible 3 4314 07B3 07E:0 Not Visible 4 4314 07F:1 Not Visible 4 4314

These LUN values differ from the LUNs actually assigned on the FA (0B1-0B4):

# symcfg list -address -FA 07E -P 0 -sid 54 Symmetrix ID: 000192601254 Director Device Name Attr Address ---------------------- ----------------------------- ---- -------------- Ident Symbolic Port Sym Physical VBUS TID LUN ------ -------- ---- ---- ----------------------- ---- --- --- FA-7E 07E 0 0054 c3t500009720139918d0s* ACLX 0 00 000 0055 Not Visible 0 00 001 0056 Not Visible 0 00 002 0088 Not Visible 0 00 003 ... 0091 Not Visible 0 00 0AF 0092 Not Visible 0 00 0B0 07B0 Not Visible 0 00 0B1 07B1 Not Visible 0 00 0B2 07B2 Not Visible 0 00 0B3 07B3 Not Visible 0 00 0B4 00B0 Not Visible 0 00 0C0 00B1 Not Visible 0 00 0C1 ... 00A5 Not Visible 0 00 0F5 00A6 Not Visible 0 00 0F6 00A7 Not Visible 0 00 0F7 Total ---- Mapped Devices: 205 Including Metamembers: 205 Available Addresses: 3884 (s)

After running the host commands to configure the devices, they are now available to the operating system on two paths with LUNs 001 - 004:

# syminq -sym

Page 37: 72361703-smc-autoprovisioning

37

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Device Product Device --------------------------------- --------------------- --------------------- Name Type ID Rev Ser Num Cap (KB) --------------------------------- --------------------- --------------------- /dev/rdsk/c3t500009*18d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t500009*18d1s2 SYMMETRIX 5874 54007B0000 4417920 /dev/rdsk/c3t500009*18d2s2 SYMMETRIX 5874 54007B1000 4417920 /dev/rdsk/c3t500009*18d3s2 SYMMETRIX 5874 54007B2000 4417920 /dev/rdsk/c3t500009*18d4s2 SYMMETRIX 5874 54007B3000 4417920 /dev/rdsk/c4t500009*19d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t500009*59d1s2 SYMMETRIX 5874 54007B0000 4417920 /dev/rdsk/c4t500009*59d2s2 SYMMETRIX 5874 54007B1000 4417920 /dev/rdsk/c4t500009*59d3s2 SYMMETRIX 5874 54007B2000 4417920 /dev/rdsk/c4t500009*59d4s2 SYMMETRIX 5874 54007B3000 4417920

When adding devices to an existing storage group using a list of devices in the command line, both a starting LUN and specific LUNs for the devices in the list may be specified.

In the following example, an existing host has a group of devices assigned but only sees the ACLX device. If gatekeepers are assigned, it might be desirable to give them high LUN numbers so that they appear at the end of the device list while also adding new devices that use the next LUNs available to the initiator. Devices 907 and 908 and gatekeepers 0AC and 0AD will be added to the storage group. The first two devices will be given LUNs 015 and 016 (21 and 22 in decimal); the second two devices will be given LUNs 0F0 and 0F1 (240 and 241):

# symaccess show view licoa057_1_view -sid 54 Symmetrix ID : 000192601254 Masking View Name : licoa057_1_view Initiator Group Name : licoa057_1_hba Host Initiators { WWN : 10000000c9767816 } Port Group Name : licoa057_1_port Director Identification { FA-7E:0 } Storage Group Name : licoa057_1_stor Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 07DB 07E:0 c3t5000097208139918d1s* 1 4314 07DC 07E:0 c3t5000097208139918d2s* 2 4314

Page 38: 72361703-smc-autoprovisioning

38

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

07DD 07E:0 c3t5000097208139918d3s* 3 4314 07DE 07E:0 c3t5000097208139918d4s* 4 4314 0833 07E:0 c3t5000097208139918d5s* 5 4314 0834 07E:0 c3t5000097208139918d6s* 6 4314 0835 07E:0 c3t5000097208139918d7s* 7 4314 0836 07E:0 c3t5000097208139918d8s* 8 4314 0837 07E:0 c3t5000097208139918d9s* 9 4314 0838 07E:0 c3t5000097208139918d10* a 4314 0839 07E:0 c3t5000097208139918d11* b 4314 083A 07E:0 c3t5000097208139918d12* c 4314 083B 07E:0 c3t5000097208139918d13* d 4314 083C 07E:0 c3t5000097208139918d14* e 4314 083D 07E:0 c3t5000097208139918d15* f 4314 083E 07E:0 c3t5000097208139918d16* 10 4314 092A 07E:0 c3t5000097208139918d17* 11 4314 092B 07E:0 c3t5000097208139918d18* 12 4314 092C 07E:0 c3t5000097208139918d19* 13 4314 092D 07E:0 c3t5000097208139918d20* 14 4314 # symaccess -sid 54 -name licoa057_1_stor -type storage add devs 907,908,0AC,0AD -lun 015,016,0F0,0F1

The devices have been added to the storage group and are mapped and masked with the specified dynamic LUN addresses:

# symaccess show view licoa057_1_view -sid 54 Symmetrix ID : 000192601254 Masking View Name : licoa057_1_view Initiator Group Name : licoa057_1_hba Host Initiators { WWN : 10000000c9767816 } Port Group Name : licoa057_1_port Director Identification { FA-7E:0 } Storage Group Name : licoa057_1_stor Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 07DB 07E:0 c3t5000097208139918d1s* 1 4314 07DC 07E:0 c3t5000097208139918d2s* 2 4314 07DD 07E:0 c3t5000097208139918d3s* 3 4314 07DE 07E:0 c3t5000097208139918d4s* 4 4314 0833 07E:0 c3t5000097208139918d5s* 5 4314 0834 07E:0 c3t5000097208139918d6s* 6 4314 0835 07E:0 c3t5000097208139918d7s* 7 4314

Page 39: 72361703-smc-autoprovisioning

39

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

0836 07E:0 c3t5000097208139918d8s* 8 4314 0837 07E:0 c3t5000097208139918d9s* 9 4314 0838 07E:0 c3t5000097208139918d10* a 4314 0839 07E:0 c3t5000097208139918d11* b 4314 083A 07E:0 c3t5000097208139918d12* c 4314 083B 07E:0 c3t5000097208139918d13* d 4314 083C 07E:0 c3t5000097208139918d14* e 4314 083D 07E:0 c3t5000097208139918d15* f 4314 083E 07E:0 c3t5000097208139918d16* 10 4314 092A 07E:0 c3t5000097208139918d17* 11 4314 092B 07E:0 c3t5000097208139918d18* 12 4314 092C 07E:0 c3t5000097208139918d19* 13 4314 092D 07E:0 c3t5000097208139918d20* 14 4314 0907 07E:0 Not Visible 15 4314 0908 07E:0 Not Visible 16 4314 00AC 07E:0 Not Visible f0 5 00AD 07E:0 Not Visible f1 5

The LUNs that are actually assigned on the FA are different from the dynamically assigned LUNs:

# symcfg list -address -FA 07E -P 0 -sid 54 Symmetrix ID: 000192601254 Director Device Name Attr Address ---------------------- ----------------------------- ---- -------------- Ident Symbolic Port Sym Physical VBUS TID LUN ------ -------- ---- ---- ----------------------- ---- --- --- FA-7E 07E 0 0054 c3t5000097208139918d0s* ACLX 0 00 000 0055 Not Visible 0 00 001 0056 Not Visible 0 00 002 0088 Not Visible 0 00 003 ... 00AA Not Visible 0 00 0B7 00AB Not Visible 0 00 0B8 00AC c3t5000097208139918d24* 0 00 0B9 00AD c3t5000097208139918d24* 0 00 0BA 00AE Not Visible 0 00 0BB 00AF Not Visible 0 00 0BC 0907 c3t5000097208139918d21* 0 00 0BD 0908 c3t5000097208139918d22* 0 00 0BE 00B0 Not Visible 0 00 0C0 00B1 Not Visible 0 00 0C1 ... 00A4 Not Visible 0 00 0F4 00A5 Not Visible 0 00 0F5 00A6 Not Visible 0 00 0F6 00A7 Not Visible 0 00 0F7 Total ---- Mapped Devices: 215 Including Metamembers: 215 Available Addresses: 3874 (s)

After configuring the devices to the host, the host special device files

Page 40: 72361703-smc-autoprovisioning

40

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

have been created using the dynamic LUN addresses:

# syminq -sym Device Product Device ---------------------------------- --------------------- --------------------- Name Type ID Rev Ser Num Cap (KB) ---------------------------------- --------------------- --------------------- /dev/rdsk/c3t500009*8d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t500009*8d1s2 SYMMETRIX 5874 54007DB000 4417920 /dev/rdsk/c3t500009*8d2s2 SYMMETRIX 5874 54007DC000 4417920 /dev/rdsk/c3t500009*8d3s2 BCV SYMMETRIX 5874 54007DD000 4417920 /dev/rdsk/c3t500009*8d4s2 SYMMETRIX 5874 54007DE000 4417920 /dev/rdsk/c3t500009*8d5s2 R1 SYMMETRIX 5874 5400833000 4417920 /dev/rdsk/c3t500009*8d6s2 R1 SYMMETRIX 5874 5400834000 4417920 /dev/rdsk/c3t500009*8d7s2 R1 SYMMETRIX 5874 5400835000 4417920 /dev/rdsk/c3t500009*8d8s2 R1 SYMMETRIX 5874 5400836000 4417920 /dev/rdsk/c3t500009*8d9s2 SYMMETRIX 5874 5400837000 4417920 /dev/rdsk/c3t500009*8d10s2 SYMMETRIX 5874 5400838000 4417920 /dev/rdsk/c3t500009*8d11s2 SYMMETRIX 5874 5400839000 4417920 /dev/rdsk/c3t500009*8d12s2 SYMMETRIX 5874 540083A000 4417920 /dev/rdsk/c3t500009*8d13s2 SYMMETRIX 5874 540083B000 4417920 /dev/rdsk/c3t500009*8d14s2 SYMMETRIX 5874 540083C000 4417920 /dev/rdsk/c3t500009*8d15s2 SYMMETRIX 5874 540083D000 4417920 /dev/rdsk/c3t500009*8d16s2 SYMMETRIX 5874 540083E000 4417920 /dev/rdsk/c3t500009*8d17s2 SYMMETRIX 5874 540092A000 4417920 /dev/rdsk/c3t500009*8d18s2 SYMMETRIX 5874 540092B000 4417920 /dev/rdsk/c3t500009*8d19s2 SYMMETRIX 5874 540092C000 4417920 /dev/rdsk/c3t500009*8d20s2 SYMMETRIX 5874 540092D000 4417920 /dev/rdsk/c3t500009*8d21s2 SYMMETRIX 5874 5400907000 4417920 /dev/rdsk/c3t500009*8d22s2 SYMMETRIX 5874 5400908000 4417920 /dev/rdsk/c3t500009*8d240s2 GK SYMMETRIX 5874 54000AC000 5760 /dev/rdsk/c3t500009*8d241s2 GK SYMMETRIX 5874 54000AD000 5760

After running symcfg discover, the special device files appear in the symaccess show view output:

# symaccess show view licoa057_1_view -sid 54 Symmetrix ID : 000192601254 Masking View Name : licoa057_1_view Initiator Group Name : licoa057_1_hba Host Initiators { WWN : 10000000c9767816 } Port Group Name : licoa057_1_port Director Identification { FA-7E:0 }

Page 41: 72361703-smc-autoprovisioning

41

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Storage Group Name : licoa057_1_stor Sym Dev Host Name Dir:P Physical Device Name Lun Attr Cap(MB) ------ ----- ----------------------- ---- ---- ------- 07DB 07E:0 c3t5000097208139918d1s* 1 4314 07DC 07E:0 c3t5000097208139918d2s* 2 4314 07DD 07E:0 c3t5000097208139918d3s* 3 4314 07DE 07E:0 c3t5000097208139918d4s* 4 4314 0833 07E:0 c3t5000097208139918d5s* 5 4314 0834 07E:0 c3t5000097208139918d6s* 6 4314 0835 07E:0 c3t5000097208139918d7s* 7 4314 0836 07E:0 c3t5000097208139918d8s* 8 4314 0837 07E:0 c3t5000097208139918d9s* 9 4314 0838 07E:0 c3t5000097208139918d10* a 4314 0839 07E:0 c3t5000097208139918d11* b 4314 083A 07E:0 c3t5000097208139918d12* c 4314 083B 07E:0 c3t5000097208139918d13* d 4314 083C 07E:0 c3t5000097208139918d14* e 4314 083D 07E:0 c3t5000097208139918d15* f 4314 083E 07E:0 c3t5000097208139918d16* 10 4314 092A 07E:0 c3t5000097208139918d17* 11 4314 092B 07E:0 c3t5000097208139918d18* 12 4314 092C 07E:0 c3t5000097208139918d19* 13 4314 092D 07E:0 c3t5000097208139918d20* 14 4314 0907 07E:0 c3t5000097208139918d21* 15 4314 0908 07E:0 c3t5000097208139918d22* 16 4314 00AC 07E:0 c3t5000097208139918d24* f0 5 00AD 07E:0 c3t5000097208139918d24* f1 5

More information about using dynamic LUN addressing can be found in the Symmetrix Dynamic LUN Addressing Technical Note, which is available on the EMC Powerlink® website.

Specifying HBA flags

The symaccess command can be used to set port flags on both initiator groups and also on individual host bus adapters within an initiator group. This functionality allows multiple operating systems to easily share FA ports by moving the place where the flags are set from the FA port to the HBA or initiator group.

The following flags can be set on the initiator group:

Volume_Set_Addressing [V]

Common_Serial_Number [C]

Disable_Q_Reset_on_UA [D]

Environ_Set [E]

Avoid_Reset_Broadcast [ARB]

AS400 [AS4]

Page 42: 72361703-smc-autoprovisioning

42

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

OpenVMS [OVMS]

SCSI_3 [SC3]

SPC2_Protocol_Version [SPC2]

SCSI_Support1 [OS2007]

All of the HBA flags can be set on an individual HBA or an entire initiator group with the exception of the Volume Set Addressing flag.

As the Volume Set Addressing flag affects the LUN addressing scheme in support of HP-UX environments, it can only be set at the initiator group level. The V flag prevents LUNs 8 – F from being assigned to a volume. It is not applicable for any other host environment and must be set on the port or on the initiator group. The V flag can apply to both child and parent initiator groups, but must be consistent across them. If an attempt is made to add an initiator group to another IG to form a cascaded IG and a child group has the V flag set but the parent does not, the command will fail:

Note: In many cases, setting a flag at the group level is preferable to setting it at the initiator level. Setting the flag on the IG propagates the setting to all initiators in the group and guarantees that any initiators added to the group at a later time will inherit the same settings.

To view the current flags set on an initiator group:

# symaccess -sid 54 -type init show licoa057_init -detail Symmetrix ID : 000192601554 Initiator Group Name : licoa057_init Last updated at : 10:06:11 AM on Mon Dec 21,2009 Port Flag Overrides : No Consistent Lun : No Originator Port wwn : 10000000c9767817 User-generated Name : 10000000c9767817/10000000c9767817 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre Originator Port wwn : 10000000c9767816 User-generated Name : 10000000c9767816/10000000c9767816 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre

Page 43: 72361703-smc-autoprovisioning

43

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

To set the Disable_Q_Reset_on_UA or D flag on an initiator group:

# symaccess -sid 54 -type init -name licoa057_init set ig_flags on D –enable

The Disable_Q_Reset_on_UA is now set on the initiator group and all initiators belonging to it. The Port Flag Overrides field indicates that a port flag has been set on the IG, and also for each HBA:

# symaccess -sid 54 -type init show licoa057_init -detail Symmetrix ID : 000192601554 Initiator Group Name : licoa057_init Last updated at : 12:07:00 PM on Mon Mar 15,2010 Port Flag Overrides : Yes Enabled : Disable_Q_Reset_on_UA(D) Disabled : N/A Consistent Lun : No Originator Port wwn : 10000000c9767817 User-generated Name : 10000000c9767817/10000000c9767817 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : Yes Enabled : Disable_Q_Reset_on_UA(D) Disabled : N/A CHAP Enabled : N/A Type : Fibre Originator Port wwn : 10000000c9767816 User-generated Name : 10000000c9767816/10000000c9767816 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : Yes Enabled : Disable_Q_Reset_on_UA(D) Disabled : N/A CHAP Enabled : N/A Type : Fibre

To remove the IG flag that was just set:

# symaccess -sid 54 -name licoa057_init -type initiator set ig_flags off D # symaccess -sid 54 -type init show licoa057_init -detail Symmetrix ID : 000192601554 Initiator Group Name : licoa057_init Last updated at : 09:40:11 AM on Tue Mar 16,2010 Port Flag Overrides : No

Page 44: 72361703-smc-autoprovisioning

44

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Consistent Lun : No Originator Port wwn : 10000000c9767817 User-generated Name : 10000000c9767817/10000000c9767817 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre Originator Port wwn : 10000000c9767816 User-generated Name : 10000000c9767816/10000000c9767816 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre

To set a flag by using the HBA WWN, the following can be run, which in this case sets the D flag on only one of the initiators in the IG and not the entire group:

# symaccess -sid 54 -wwn 10000000c9767817 set hba_flags on D –enable

The Port Flag Overrides field indicates that the override applies only to one of the HBAs in the IG:

# symaccess -sid 54 -type init show licoa057_init -detail Symmetrix ID : 000192601554 Initiator Group Name : licoa057_init Last updated at : 09:53:14 AM on Tue Mar 16,2010 Port Flag Overrides : No Consistent Lun : No Originator Port wwn : 10000000c9767817 User-generated Name : 10000000c9767817/10000000c9767817 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : Yes Enabled : Disable_Q_Reset_on_UA(D) Disabled : N/A CHAP Enabled : N/A Type : Fibre Originator Port wwn : 10000000c9767816 User-generated Name : 10000000c9767816/10000000c9767816 FCID Lockdown : No Heterogeneous Host : No

Page 45: 72361703-smc-autoprovisioning

45

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre

To unset the flag on the WWN:

# symaccess -sid 54 -wwn 10000000c9767817 set hba_flag off D # symaccess -sid 54 -type init show licoa057_init -detail Symmetrix ID : 000192601554 Initiator Group Name : licoa057_init Last updated at : 09:58:16 AM on Tue Mar 16,2010 Port Flag Overrides : No Consistent Lun : No Originator Port wwn : 10000000c9767817 User-generated Name : 10000000c9767817/10000000c9767817 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre Originator Port wwn : 10000000c9767816 User-generated Name : 10000000c9767816/10000000c9767816 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre

Note: There is some dependency between the OS2007 and SPC2 flags. The OS2007 flag can only be set or enabled on the initiator or group when the SPC2 flag is set or enabled on the same initiator or group. The reverse is also true; the SPC2 flag can not be set, disabled, or turned off while the OS2007 flag is set or enabled.

Overriding port flags

Flags that are set on the FA port can be also be overridden. In this case, the ports that this host is using to access the Symmetrix has the common serial number (C) flag set:

# symaccess -sid 54 show licoa057_port -type port Symmetrix ID : 000192601554 Port Group Name : licoa057_port

Page 46: 72361703-smc-autoprovisioning

46

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Last updated at : 10:06:11 AM on Mon Dec 21,2009 Director Identification { FA-7E:0 FA-10E:1 } Masking View Names { licoa057_view } # symcfg -sid 54 list -FA 7E -p 0 -v Symmetrix ID: 000192601554 ... SCSI Flags { Negotiate_Reset(N) : Disabled Soft_Reset(S) : Disabled Environ_Set(E) : Disabled HP3000_Mode(B) : Disabled Common_Serial_Number(C) : Enabled Disable_Q_Reset_on_UA(D) : Disabled Sunapee(SCL) : Disabled Siemens(S) : Disabled Sequent(SEQ) : Disabled Avoid_Reset_Broadcast(ARB) : Disabled Server_On_AS400(A4S) : Disabled SCSI_3(SC3) : Enabled SPC2_Protocol_Version(SPC2) : Enabled SCSI_Support1(OS2007) : Disabled } Fibre Specific Flags { Volume_Set_Addressing(V) : Disabled Non_Participating(NP) : Disabled Init_Point_to_Point(PP) : Enabled Unique_WWN(UWN) : Enabled Access_Logix(ACLX) : Enabled OpenVMS(OVMS) : Disabled AS400(AS4) : Disabled Auto_Negotiate(EAN) : Enabled } # symcfg -sid 54 list -FA 10E -p 1 -v Symmetrix ID: 000192601554 ... SCSI Flags { Negotiate_Reset(N) : Disabled Soft_Reset(S) : Disabled

Page 47: 72361703-smc-autoprovisioning

47

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Environ_Set(E) : Disabled HP3000_Mode(B) : Disabled Common_Serial_Number(C) : Enabled Disable_Q_Reset_on_UA(D) : Disabled Sunapee(SCL) : Disabled Siemens(S) : Disabled Sequent(SEQ) : Disabled Avoid_Reset_Broadcast(ARB) : Disabled Server_On_AS400(A4S) : Disabled SCSI_3(SC3) : Enabled SPC2_Protocol_Version(SPC2) : Enabled SCSI_Support1(OS2007) : Disabled } Fibre Specific Flags { Volume_Set_Addressing(V) : Disabled Non_Participating(NP) : Disabled Init_Point_to_Point(PP) : Enabled Unique_WWN(UWN) : Enabled Access_Logix(ACLX) : Enabled OpenVMS(OVMS) : Disabled AS400(AS4) : Disabled Auto_Negotiate(EAN) : Enabled }

The common serial number flag causes the serial number returned in response to a SCSI inquiry to end in all zeros:

# syminq Device Product Device ---------------------------- --------------------------- --------------------- Name Type Vendor ID Rev Ser Num Cap (KB) ---------------------------- --------------------------- --------------------- /dev/rdsk/c3t5*d0s2 EMC SYMMETRIX 5874 54003A9000 4417920 /dev/rdsk/c3t5*d1s2 EMC SYMMETRIX 5874 54003AA000 4417920 /dev/rdsk/c3t5*d2s2 EMC SYMMETRIX 5874 54003AB000 4417920 /dev/rdsk/c3t5*d3s2 EMC SYMMETRIX 5874 54003AC000 4417920 /dev/rdsk/c3t5*d4s2 EMC SYMMETRIX 5874 54003AD000 4417920 /dev/rdsk/c3t5*d5s2 EMC SYMMETRIX 5874 54003AE000 4417920 /dev/rdsk/c3t5*d6s2 EMC SYMMETRIX 5874 54003AF000 4417920 /dev/rdsk/c3t5*d7s2 EMC SYMMETRIX 5874 54003B0000 4417920 ...

The IG currently has no port flags set and no port flags overridden:

# symaccess -sid 54 -type init show licoa057_init -detail Symmetrix ID : 000192601554 Initiator Group Name : licoa057_init Last updated at : 09:58:16 AM on Tue Mar 16,2010 Port Flag Overrides : No Consistent Lun : No

Page 48: 72361703-smc-autoprovisioning

48

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Originator Port wwn : 10000000c9767817 User-generated Name : 10000000c9767817/10000000c9767817 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre Originator Port wwn : 10000000c9767816 User-generated Name : 10000000c9767816/10000000c9767816 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre

To unset the flag for just the initiators in an IG while leaving it set on the port, the –disable option is used along with the “on” option. The flag cannot simply be turned off at the IG level because the IG is not overriding the flag. It must be turned 'on' at the initiator group to turn on the override of the flag. It can then be disabled so that the override action is to unset the flag:

# symaccess -sid 54 -name licoa057_init -type initiator set ig_flags on C –disable # symaccess -sid 54 -type init show licoa057_init -detail Symmetrix ID : 000192601554 Initiator Group Name : licoa057_init Last updated at : 07:33:24 AM on Wed Mar 17,2010 Port Flag Overrides : Yes Enabled : N/A Disabled : Common_Serial_Number(C) Consistent Lun : No Originator Port wwn : 10000000c9767817 User-generated Name : 10000000c9767817/10000000c9767817 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : Yes Enabled : N/A Disabled : Common_Serial_Number(C) CHAP Enabled : N/A Type : Fibre Originator Port wwn : 10000000c9767816 User-generated Name : 10000000c9767816/10000000c9767816 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : Yes

Page 49: 72361703-smc-autoprovisioning

49

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Enabled : N/A Disabled : Common_Serial_Number(C) CHAP Enabled : N/A Type : Fibre

The full serial number, which now includes FA and port numbers, is now being displayed in syminq output:

# syminq Device Product Device ---------------------------- --------------------------- --------------------- Name Type Vendor ID Rev Ser Num Cap (KB) ---------------------------- --------------------------- --------------------- /dev/rdsk/c3t57208* EMC SYMMETRIX 5874 54003A9470 4417920 /dev/rdsk/c3t57208* EMC SYMMETRIX 5874 54003AA470 4417920 /dev/rdsk/c3t57208* EMC SYMMETRIX 5874 54003AB470 4417920 /dev/rdsk/c3t57208* EMC SYMMETRIX 5874 54003AC470 4417920 /dev/rdsk/c3t57208* EMC SYMMETRIX 5874 54003AD470 4417920 /dev/rdsk/c3t57208* EMC SYMMETRIX 5874 54003AE470 4417920 /dev/rdsk/c3t57208* EMC SYMMETRIX 5874 54003AF470 4417920 /dev/rdsk/c3t50208* EMC SYMMETRIX 5874 54003B0470 4417920 ...

Now that the flag is set on the IG, it can be turned off on the IG by using the “off” option:

# symaccess -sid 54 -name licoa057_init -type initiator set ig_flags off C # symaccess -sid 54 -type init show licoa057_init -detail Symmetrix ID : 000192601554 Initiator Group Name : licoa057_init Last updated at : 07:53:07 AM on Wed Mar 17,2010 Port Flag Overrides : No Consistent Lun : No Originator Port wwn : 10000000c9767817 User-generated Name : 10000000c9767817/10000000c9767817 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre Originator Port wwn : 10000000c9767816 User-generated Name : 10000000c9767816/10000000c9767816 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre

Page 50: 72361703-smc-autoprovisioning

50

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

# syminq Device Product Device ---------------------------- --------------------------- --------------------- Name Type Vendor ID Rev Ser Num Cap (KB) ---------------------------- --------------------------- --------------------- /dev/rdsk/c3t5*d0s2 EMC SYMMETRIX 5874 54003A9000 4417920 /dev/rdsk/c3t5*d1s2 EMC SYMMETRIX 5874 54003AA000 4417920 /dev/rdsk/c3t5*d2s2 EMC SYMMETRIX 5874 54003AB000 4417920 /dev/rdsk/c3t5*d3s2 EMC SYMMETRIX 5874 54003AC000 4417920 /dev/rdsk/c3t5*d4s2 EMC SYMMETRIX 5874 54003AD000 4417920 /dev/rdsk/c3t5*d5s2 EMC SYMMETRIX 5874 54003AE000 4417920 /dev/rdsk/c3t5*d6s2 EMC SYMMETRIX 5874 54003AF000 4417920 /dev/rdsk/c3t5*d7s2 EMC SYMMETRIX 5874 54003B0000 4417920 ...

Insuring consistent LUNs across initiators

In some host environments, it is a requirement that volumes be assigned to the same LUN value on all channels. To facilitate this, the –consistent_lun option can be used when creating initiator groups. For example:

# symaccess -sid 51 create -name licoa058_init -type initiator -file clustnodeA_WWN_file –consistent_lun # symaccess -sid 51 show licoa098_init -type initiator -detail Symmetrix ID : 000192601551 Initiator Group Name : licoa098_init Last updated at : 11:06:41 AM on Tue Mar 23,2010 Port Flag Overrides : No Consistent Lun : Yes Originator Port wwn : 10000000c97a7659 User-generated Name : 10000000c97a7659/10000000c97a7659 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre Originator Port wwn : 10000000c97a765a User-generated Name : 10000000c97a765a/10000000c97a765a FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre

When the consistent_lun flag is set on an IG and when it is added to a masking view, all volumes in associated storage groups will be assigned

Page 51: 72361703-smc-autoprovisioning

51

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

identical LUNs on all channels as mapping and masking are performed by the Symmetrix.

The -consistent_lun option can apply to both child and parent initiator groups but must be consistent across them. If an attempt is made to add an initiator group to another IG to form a cascaded IG and a child group has the consistent_lun flag set but the parent does not, the command will fail:

# symaccess -sid 51 create -name licoa099_init -type initiator -f clustnodeB_WWN_file # symaccess -sid 51 show licoa099_init -type initiator -detail Symmetrix ID : 000192601551 Initiator Group Name : licoa099_init Last updated at : 11:15:31 AM on Tue Mar 23,2010 Port Flag Overrides : No Consistent Lun : No Originator Port wwn : 10000000c976c3e5 User-generated Name : 10000000c976c3e5/10000000c976c3e5 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre Originator Port wwn : 10000000c976c3e6 User-generated Name : 10000000c976c3e6/10000000c976c3e6 FCID Lockdown : No Heterogeneous Host : No Port Flag Overrides : No CHAP Enabled : N/A Type : Fibre # symaccess -sid 51 show licoaCLUST_init -type initiator -detail Symmetrix ID : 000192601551 Initiator Group Name : licoaCLUST_init Last updated at : 11:13:35 AM on Tue Mar 23,2010 Port Flag Overrides : No Consistent Lun : Yes Group Name : licoa098_init User-generated Name : N/A FCID Lockdown : N/A Heterogeneous Host : N/A Port Flag Overrides : N/A CHAP Enabled : N/A Type : Initiator Group

Page 52: 72361703-smc-autoprovisioning

52

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

# symaccess -sid 51 add -name licoaCLUST_init -type initiator -ig licoa099_init The operation will result in consistent lun violation

In this situation, the set command would allow the user to set this flag on the child after it has been created. This would allow the child initiator group to be added to the parent IG:

# symaccess -sid 51 set -name licoa099_init set consistent_lun on

Provisioning storage by using SMC

The following use cases illustrate various ways that initiator groups can be used to provide access to Symmetrix volumes using SMC.

Presenting storage to a SYMAPI control host

In the first example, gatekeepers need to be provisioned to a management host that will be the SMC server. Best practice for assigning gatekeepers to hosts specifies that gatekeeper device be assigned on only a single front-end path.

Figure 3 Creating individual paths to gatekeepers

Steps for provisioning storage

The following are the general steps that can be followed to accomplish this goal:

Page 53: 72361703-smc-autoprovisioning

53

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

1. Create a storage group containing the gatekeepers that will be accessed on path 0.

2. Create a storage group containing the gatekeepers that will be accessed on path 1.

3. Create a port group containing the port for path 0.

4. Create a port group containing the port for path 1.

5. Create an initiator group containing the HBA for path 0.

6. Create an initiator group for the initiator for path 1.

7. Create a masking view for path 0.

8. Create a masking view for path 1.

Once the masking view has been created, the devices are available to the initiators on the storage ports. Host-specific commands can then be run to configure the devices to the operating system.

Example of provisioning storage

The folders containing all of the initiator groups entities can be found in the Masking Views folder in the tree view pane under the Symmetrix serial number:

Figure 4 Masking Views folder

Step 1 - Create a storage group containing the gatekeepers that will be accessed on path 0.

The dialog box used to create storage groups can be accessed by right-clicking on either the Symmetrix serial number, the Symmetrix Masking Views folder, or the Storage Groups folder, then by selecting Device

Page 54: 72361703-smc-autoprovisioning

54

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Masking and Mapping > Storage Groups Maintenance > Create Storage Group ...

Figure 5 Creating storage groups

Page 55: 72361703-smc-autoprovisioning

55

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

In the Create dialog box, the group name can be entered. The user can also choose the Devices Source Type from a pull-down menu. This allows the user to choose devices manually from a list of available Symmetrix devices or from a device group, composite group, or storage template.

In this example, three gatekeepers (05A, 05B, and 05C) are chosen from a list of available Symmetrix devices. After selecting them and clicking Add they are put into the Group Members field. After clicking OK, the storage group is created.

Figure 6 Viewing a storage group

Step 2 – Follow the same steps and create a storage group containing the gatekeepers that will be accessed on path 1.

Step 3 – Create a port group containing the port for path 0.

The dialog box used to create port groups can be accessed by right-clicking on either the Symmetrix serial number, the Symmetrix Masking folder, or the Port Groups folder, then by selecting Device Masking and Mapping > Port Groups Maintenance > Create Port Group ...

Page 56: 72361703-smc-autoprovisioning

56

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Figure 7 Creating port groups

Page 57: 72361703-smc-autoprovisioning

57

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

After naming the port group, selecting the desired port (7E:0), clicking Add, and clicking OK, the port group will be created:

Figure 8 Viewing a port group

Step 4 – Follow the same steps and create a port group containing the port that will be used on path 1.

Step 5 – Create an initiator group containing the HBA for path 0.

The dialog box used to create initiator groups can be accessed by right-clicking on either the Symmetrix serial number, the Symmetrix Masking folder, or the Initiator Groups folder, then by selecting Device Masking and Mapping > Initiator Groups Maintenance > Create Initiator Group ...

Page 58: 72361703-smc-autoprovisioning

58

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Figure 9 Creating initiator groups

With initiator groups, the WWN of the HBA can be chosen from a list of available initiators or a new initiator that has not been discovered yet can be entered manually.

After naming the initiator group, selecting the initiator, clicking Add, and clicking OK, the initiator group will be created:

Figure 10 Viewing an initiator group

Page 59: 72361703-smc-autoprovisioning

59

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Step 6 – Follow the same steps and create an initiator group containing the HBA for path 0.

Step 7 – Create a masking view for path 0.

The dialog box used to create a masking view can be accessed by right-clicking on either the Symmetrix serial number, the Symmetrix Masking folder, or the Masking Views folder, then by selecting Device Masking and Mapping > Masking Views Maintenance > Create Masking View ...

After entering in the masking view name, the storage group can be selected from a list by clicking the Select button to bring up the Select a Storage Group dialog box.

Figure 11 Selecting a storage group

After the storage group is selected, the port and initiator groups can be selected in the same manner.

Page 60: 72361703-smc-autoprovisioning

60

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Figure 12 Selecting a port and initiator group

After they have been chosen, clicking OK will cause SMC to perform the mapping and masking. When the operation is complete, the masking view is created and the gatekeepers are available to the host:

Figure 13 Viewing a masking view # syminq -sym Device Product Device ---------------------------------- --------------------- --------------------- Name Type ID Rev Ser Num Cap (KB) ---------------------------------- --------------------- --------------------- /dev/rdsk/c3t500009*918d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t500009*918d1s2 GK SYMMETRIX 5874 540005A000 5760 /dev/rdsk/c3t500009*918d2s2 GK SYMMETRIX 5874 540005B000 5760 /dev/rdsk/c3t500009*918d3s2 GK SYMMETRIX 5874 540005C000 5760 /dev/rdsk/c4t500009*959d0s2 GK SYMMETRIX 5874 5400054000 5760

Page 61: 72361703-smc-autoprovisioning

61

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Step 8 – Follow the same steps and create a masking view for Path 1.

Presenting storage to a production and a backup host

This use case shows a simplified configuration in which the storage administrator needs to provision storage to two newly attached hosts. In this example, one of the machines is a production database server and the other is a database backup server that will access clones of the production volumes. Each host will access its own set of devices through two HBAs zoned to the VMAX array on the same FA ports.

Figure 14 Storage presented to a production and a backup host

Steps for provisioning storage

To make the storage available to the appropriate host, the storage groups, port group, and initiator groups must be created. The applicable groups must then be combined into a masking view for each host, which will do the mapping and masking so that the storage is accessible.

In this example a Symmetrix device group will be created and will be used to provide the device lists for the storage groups.

The following are the general steps that can be followed to accomplish this goal:

1. Create a Symmetrix device group that contains the production volumes and the clone target volumes.

2. Create the production storage group that contains the production

Page 62: 72361703-smc-autoprovisioning

62

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

volumes.

3. Create the backup storage group that contains the clone target volumes.

4. Create the port group.

5. Create the production server initiator group.

6. Create the backup server initiator group.

7. Create the production server masking view containing the production storage group, port group, and production initiator group.

8. Create the backup server masking view containing the backup storage group, port group, and backup initiator group.

Once the masking view has been created, the devices are available to the initiators on the storage ports. Host-specific commands can then be run to configure the devices to the operating system.

Example of provisioning storage

Step 1 - Create a Symmetrix device group, add the production volumes, and add the clone target volumes. The dialog box used to create device groups can be accessed by right-clicking on the Device Groups folder then by selecting DG/CG Management > Create Group ...

Page 63: 72361703-smc-autoprovisioning

63

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Figure 15 Creating device groups

The standard volumes (STD) for the production host and the target volumes (TGT) for the backup host can now be selected. Selecting the STD device type brings up a list of available Standards. The following figure shows four devices (7DB – 7DE) are chosen:

Page 64: 72361703-smc-autoprovisioning

64

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Figure 16 Selecting volumes

Selecting the TGT device type brings up a list of devices that are available to be used as clone targets. The four clone targets (7DF – 7E2) can be selected and added to the device group:

Page 65: 72361703-smc-autoprovisioning

65

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Figure 17 Adding clone targets to the device group

After clicking OK, the device group is created.

Figure 18 Viewing a device group

Step 2 - Create the production storage group that contains the production volumes. For this step, the device group will be used to provide the device list.

The dialog box used to create storage groups can be accessed by right-clicking on either the Symmetrix serial number, the Symmetrix Masking

Page 66: 72361703-smc-autoprovisioning

66

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

folder, or the Storage Groups folder, then selecting Device Masking and Mapping > Storage Groups Maintenance > Create Storage Group ...

Figure 19 Creating storage groups

After naming the storage group, Device Group can be selected from the pull-down menu for Devices Source Type. The correct device group can then be chosen by clicking Select... next to the Device Source Name field.

When the dialog box opens, all of the devices in the device group will populate the Group Members list. In this example, only the STD devices will be part of this storage group, so the TGT devices must be removed before the storage group is created.

Page 67: 72361703-smc-autoprovisioning

67

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Figure 20 Selecting source storage group members

Step 3 – The storage group for the backup server can be created in the same way except the STD devices will be removed before clicking OK:

Page 68: 72361703-smc-autoprovisioning

68

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Figure 21 Selecting target storage group members

Both storage groups are now available:

Figure 22 Viewing a storage group

Step 4 – Create the port group containing the two Symmetrix ports to which the HBAs are zoned.

The dialog box used to create port groups can be accessed by right-clicking on either the Symmetrix serial number, the Symmetrix Masking folder, or the Port Groups folder, then by selecting Device Masking and Mapping > Port Groups Maintenance > Create Port Group ...

Page 69: 72361703-smc-autoprovisioning

69

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Figure 23 Creating port groups

In the Create dialog box, the Port Group Name can be entered and the ports chosen. In this example, both the Standard and Target devices will be available on ports 07E:0 and 07F:1:

Page 70: 72361703-smc-autoprovisioning

70

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Figure 24 Creaing a port group

After clicking OK, the port group is created:

Figure 25 Viewing a port group

Step 5 – Create the production server initiator group. The dialog box used to create initiator groups can be accessed by right-clicking on either the Symmetrix serial number, the Symmetrix Masking folder, or the

Page 71: 72361703-smc-autoprovisioning

71

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Initiator Groups folder, then by selecting Device Masking and Mapping > Initiator Groups Maintenance > Create Initiator Group ...

Figure 26 Creating the production server initiator group

With initiator groups, the WWN of the HBA can be chosen from a list of available initiators or a new initiator that has not been discovered yet can be entered manually.

After naming the initiator group, selecting the initiator, clicking Add, and then OK, the initiator group will be created:

Page 72: 72361703-smc-autoprovisioning

72

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Figure 27 Initiator group is created

Step 6 – Create the backup server initiator group in the same manner.

Step 7 – Create the production server masking view containing the production storage group, port group, and production initiator group.

The dialog box used to create a masking view can be accessed by right-clicking on either the Symmetrix serial number, the Symmetrix Masking

Page 73: 72361703-smc-autoprovisioning

73

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

folder, or the Masking Views folder, then by selecting Device Masking and Mapping > Masking Views Maintenance > Create Masking View ...

Figure 28 Creating a masking view

After entering in the masking view name, the storage group can be selected from a list by clicking Select ... to bring up the Select a Storage Group dialog box.

Page 74: 72361703-smc-autoprovisioning

74

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Figure 29 Select a Storage Group dialog box

After the storage group is selected, the port and initiator groups can be selected in the same manner:

Figure 30 Selecting port and initiator groups

After they have been chosen, clicking OK will cause SMC to perform the mapping and masking. When the operation is complete, the masking view is created and the devices are available:

Page 75: 72361703-smc-autoprovisioning

75

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Figure 31 Viewing a masking view

After running the host-specific commands to configure new devices, the Symmetrix volumes in the storage group (7DB-7DE) are available to the host:

# syminq -sym Device Product Device ---------------------------------- --------------------- --------------------- Name Type ID Rev Ser Num Cap (KB) ---------------------------------- --------------------- --------------------- /dev/rdsk/c3t5000097*18d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t5000097*18d1s2 SYMMETRIX 5874 54007DB000 4417920 /dev/rdsk/c3t5000097*18d2s2 SYMMETRIX 5874 54007DC000 4417920 /dev/rdsk/c3t5000097*18d3s2 SYMMETRIX 5874 54007DD000 4417920 /dev/rdsk/c3t5000097*18d4s2 SYMMETRIX 5874 54007DE000 4417920 /dev/rdsk/c4t5000097*59d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t5000097*59d1s2 SYMMETRIX 5874 54007DB000 4417920 /dev/rdsk/c4t5000097*59d2s2 SYMMETRIX 5874 54007DC000 4417920 /dev/rdsk/c4t5000097*59d3s2 SYMMETRIX 5874 54007DD000 4417920 /dev/rdsk/c4t5000097*59d4s2 SYMMETRIX 5874 54007DE000 4417920

Step 8 – Create the backup server masking view containing the backup storage group, port group, and backup initiator group.

Figure 32 Viewing a masking view

After running the host-specific commands to configure new devices, the Symmetrix volumes in the storage group (7DF-7E2) are available to the

Page 76: 72361703-smc-autoprovisioning

76

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

host:

# syminq -sym Device Product Device ---------------------------------- --------------------- --------------------- Name Type ID Rev Ser Num Cap (KB) ---------------------------------- --------------------- --------------------- /dev/rdsk/c3t5000097*18d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t5000097*18d1s2 SYMMETRIX 5874 54007DF000 4417920 /dev/rdsk/c3t5000097*18d2s2 SYMMETRIX 5874 54007E0000 4417920 /dev/rdsk/c3t5000097*18d3s2 SYMMETRIX 5874 54007E1000 4417920 /dev/rdsk/c3t5000097*18d4s2 SYMMETRIX 5874 54007E2000 4417920 /dev/rdsk/c4t5000097*59d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t5000097*59d1s2 SYMMETRIX 5874 54007DF000 4417920 /dev/rdsk/c4t5000097*59d2s2 SYMMETRIX 5874 54007E0000 4417920 /dev/rdsk/c4t5000097*59d3s2 SYMMETRIX 5874 54007E1000 4417920 /dev/rdsk/c4t5000097*59d4s2 SYMMETRIX 5874 54007E2000 4417920

Adding existing storage, ports, or initiators to an existing view

Adding additional Symmetrix volumes, array ports, or host initiators to the existing masking view is as simple as adding the desired element to an existing storage, port, or initiator group.

If the production environment in the previous example is running out of space and needs more storage, the following steps can be followed to make additional Symmetrix volumes available to the production host with corresponding target devices available to the backup host.

1. Add the standard devices that were placed in the device group into the production storage group.

2. Add the target devices that were placed in the device group into the backup storage group.

Example of adding storage to an existing storage group

Step 1 – Add standard devices 7E8 and 7E9 into the production storage group.

The dialog box used to modify storage groups can be accessed by right-clicking on the storage group to be modified under the Storage Groups folder, then by selecting Device Masking and Mapping > Storage Groups Maintenance > Modify Storage Group ...

Page 77: 72361703-smc-autoprovisioning

77

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Figure 33 Modifying storage groups

Choose the devices from the list of available devices, click Add to add them to the list for group members, and click OK.

Page 78: 72361703-smc-autoprovisioning

78

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Figure 34 Adding additional devices to a storage group

After clicking OK, the devices are part of the storage group. The mapping and masking is done automatically.

Figure 35 Viewing a storage group

Step 2 – Add target devices 7EA and 7EB into the backup storage group in the same way.

Page 79: 72361703-smc-autoprovisioning

79

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Figure 36 Add target devices into the backup storage group

After running the applicable host commands, standard devices 7E8 and 7E9 are available to the production host:

# syminq -sym Device Product Device ---------------------------------- --------------------- --------------------- Name Type ID Rev Ser Num Cap (KB) ---------------------------------- --------------------- --------------------- /dev/rdsk/c3t5000097*18d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t5000097*18d1s2 SYMMETRIX 5874 54007DB000 4417920 /dev/rdsk/c3t5000097*18d2s2 SYMMETRIX 5874 54007DC000 4417920 /dev/rdsk/c3t5000097*18d3s2 SYMMETRIX 5874 54007DD000 4417920 /dev/rdsk/c3t5000097*18d4s2 SYMMETRIX 5874 54007DE000 4417920 /dev/rdsk/c3t5000097*18d5s2 SYMMETRIX 5874 54007E8000 4417920 /dev/rdsk/c3t5000097*18d6s2 SYMMETRIX 5874 54007E9000 4417920 /dev/rdsk/c4t5000097*59d0s2 GK SYMMETRIX 5874 5400054000 5760

Page 80: 72361703-smc-autoprovisioning

80

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

/dev/rdsk/c4t5000097*59d1s2 SYMMETRIX 5874 54007DB000 4417920 /dev/rdsk/c4t5000097*59d2s2 SYMMETRIX 5874 54007DC000 4417920 /dev/rdsk/c4t5000097*59d3s2 SYMMETRIX 5874 54007DD000 4417920 /dev/rdsk/c4t5000097*59d4s2 SYMMETRIX 5874 54007DE000 4417920 /dev/rdsk/c4t5000097*59d5s2 SYMMETRIX 5874 54007E8000 4417920 /dev/rdsk/c4t5000097*59d6s2 SYMMETRIX 5874 54007E9000 4417920

Target devices 7EA and 7EB are available to the backup host:

# syminq -sym Device Product Device ---------------------------------- --------------------- --------------------- Name Type ID Rev Ser Num Cap (KB) ---------------------------------- --------------------- --------------------- /dev/rdsk/c3t5000097*18d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t5000097*18d1s2 SYMMETRIX 5874 54007DF000 4417920 /dev/rdsk/c3t5000097*18d2s2 SYMMETRIX 5874 54007E0000 4417920 /dev/rdsk/c3t5000097*18d3s2 SYMMETRIX 5874 54007E1000 4417920 /dev/rdsk/c3t5000097*18d4s2 SYMMETRIX 5874 54007E2000 4417920 /dev/rdsk/c3t5000097*18d5s2 SYMMETRIX 5874 54007EA000 4417920 /dev/rdsk/c3t5000097*18d6s2 SYMMETRIX 5874 54007EB000 4417920 /dev/rdsk/c4t5000097*59d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t5000097*59d1s2 SYMMETRIX 5874 54007DF000 4417920 /dev/rdsk/c4t5000097*59d2s2 SYMMETRIX 5874 54007E0000 4417920 /dev/rdsk/c4t5000097*59d3s2 SYMMETRIX 5874 54007E1000 4417920 /dev/rdsk/c4t5000097*59d4s2 SYMMETRIX 5874 54007E2000 4417920 /dev/rdsk/c4t5000097*59d5s2 SYMMETRIX 5874 54007EA000 4417920 /dev/rdsk/c4t5000097*59d6s2 SYMMETRIX 5874 54007EB000 4417920

Note: It is also possible to use the Expand Storage wizard to add devices to a storage group.

The wizard can be accessed by right-clicking on the storage group to be modified under the Storage Groups folder, then clicking Device Masking and Mapping > Storage Groups Maintenance > Expand Storage Group ...

Presenting storage to a cluster

Cascaded initiator groups can be used to assign shared volumes to cluster nodes while still assigning groups of devices that are not shared among the hosts.

This use case shows a simplified configuration in which the storage administrator needs to provision storage to two newly attached cluster nodes. In this example, both nodes of the cluster will share four Virtual Provisioning thin devices (92A – 92D). Each node will also have access to two RAID 6 devices (7DB – 7DC for node A and 7DD – 7DE for node B) that will not be available to the other host.

Page 81: 72361703-smc-autoprovisioning

81

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Figure 37 Storage presented in a clustered environment

Steps for provisioning storage using a cascaded initiator group

In this example, no Symmetrix device groups will be created. Both a device file and command line ranges will be used for the device lists.

The following are the general steps that can be followed to accomplish this goal:

1. Create a storage group that contains the volumes that will be shared among both nodes of the cluster.

2. Create a storage group that contains the volumes that will be presented to Node A only.

3. Create a storage group that contains the volumes that will be presented to Node B only.

4. Create the port group.

5. Create the initiator group for Node A.

6. Create the initiator group for Node B.

7. Create the cascaded initiator group.

8. Create the clustered device masking view containing the shared storage group, port group, and cascaded initiator group.

Page 82: 72361703-smc-autoprovisioning

82

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

9. Create the Node A masking view containing the Node A storage group, port group, and Node A initiator group.

10. Create the Node B masking view containing the Node B storage group, port group, and Node B initiator group.

After running the host commands to configure the new devices, they are available to the operating system.

Example of using a cascaded initiator group

Step 1 - Create a storage group that contains the volumes (92A – 92D) that will be shared among both nodes of the cluster. In this example the device list is provided in a device file.

The dialog box used to create storage groups can be accessed by right clicking on either the Symmetrix serial number, the Symmetrix Masking folder, or the Storage Groups folder, then by selecting Device Masking and Mapping > Storage Groups Maintenance > Create Storage Group ...

After naming the storage group, Symmetrix can be selected from the pull-down menu for Devices Source Type. The Available Devices list can be filtered or can contain all available Symmetrix devices.

Page 83: 72361703-smc-autoprovisioning

83

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Devices 92A to 92D are chosen and added to the Group Members list by selecting them and then by clicking Add. The storage group is then created by clicking OK:

Step 2 - Create a storage group that contains the volumes that will be presented to Node A only (7DB:7DC).

Page 84: 72361703-smc-autoprovisioning

84

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Step 3 - Create a storage group that contains the volumes that will be presented to Node B only (7DD:7DE).

Step 4 – Create the port group.

Page 85: 72361703-smc-autoprovisioning

85

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

The dialog box used to create port groups can be accessed by right clicking on either the Symmetrix serial number, the Symmetrix Masking folder, or the Port Groups folder, then by selecting Device Masking and Mapping > Port Groups Maintenance > Create Port Group ...

After naming the port group, select the desired ports (7E:0 and 7F:1), click Add and OK. The port group will be created:

Page 86: 72361703-smc-autoprovisioning

86

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Step 5 - Create the initiator group for Node A.

The dialog box used to create initiator groups can be accessed by right clicking on either the Symmetrix serial number, the Symmetrix Masking folder, or the Initiator Groups folder, then by selecting Device Masking and Mapping > Initiator Groups Maintenance > Create Initiator Group ...

Page 87: 72361703-smc-autoprovisioning

87

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Both HBA WWNs can be selected from the Available Initiators list. They can then be put in the Selected Initiators list by clicking Click OK to create the port group.

Page 88: 72361703-smc-autoprovisioning

88

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Step 6 - Create the initiator group for Node B.

Use the same steps to create the initiator group for Node B.

Step 7 - Create the cascaded initiator group that contains the node A and Node B initiator groups.

Cascaded initiator groups are created in the same way that regular initiator groups are created except other initiator groups are added to the cascaded group instead of individual initiators. Existing initiator groups will appear at the end of the list of available initiators. They can be selected and added to the cascaded initiator group just as regular initiators are added.

Page 89: 72361703-smc-autoprovisioning

89

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

The Cascaded or parent initiator group now contains the two child initiator groups:

Step 8 - Create the clustered device masking view containing the shared storage group, port group, and cascaded initiator group.

The dialog box used to create a masking view can be accessed by right clicking on either the Symmetrix serial number, the Symmetrix Masking folder, or the Masking Views folder, then by selecting Device Masking and Mapping > Masking Views Maintenance > Create Masking View ...

Page 90: 72361703-smc-autoprovisioning

90

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Provide a name to the view and then click the Select... next to each group and choose the correct storage, port, and initiator groups. Then click OK to create the view.

Step 9 - Create the Node A masking view containing the Node A storage group, the port group, and the Node A initiator group.

Page 91: 72361703-smc-autoprovisioning

91

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Use the same steps to create the masking view for the devices that will be seen only by Node A.

Step 10 - Create the Node B masking view containing the Node B storage group, the port group, and the Node B initiator group.

Use the same steps to create the masking view for the devices that will be seen only by Node B.

After configuring the devices from the operating systems, the correct devices are available to each cluster node:

Cluster Node A sees thin devices 92A – 92Das well as RAID-6 devices 7DB – 7DC:

# syminq -sym Device Product Device ---------------------------------- --------------------- --------------------- Name Type ID Rev Ser Num Cap (KB)

Page 92: 72361703-smc-autoprovisioning

92

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

---------------------------------- --------------------- --------------------- /dev/rdsk/c3t5000097*18d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t5000097*18d1s2 SYMMETRIX 5874 540092A000 4417920 /dev/rdsk/c3t5000097*18d2s2 SYMMETRIX 5874 540092B000 4417920 /dev/rdsk/c3t5000097*18d3s2 SYMMETRIX 5874 540092C000 4417920 /dev/rdsk/c3t5000097*18d4s2 SYMMETRIX 5874 540092D000 4417920 /dev/rdsk/c3t5000097*18d5s2 SYMMETRIX 5874 54007DB000 4417920 /dev/rdsk/c3t5000097*18d6s2 SYMMETRIX 5874 54007DC000 4417920 /dev/rdsk/c4t5000097*59d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t5000097*59d1s2 SYMMETRIX 5874 540092A000 4417920 /dev/rdsk/c4t5000097*59d2s2 SYMMETRIX 5874 540092B000 4417920 /dev/rdsk/c4t5000097*59d3s2 SYMMETRIX 5874 540092C000 4417920 /dev/rdsk/c4t5000097*59d4s2 SYMMETRIX 5874 540092D000 4417920 /dev/rdsk/c4t5000097*59d5s2 SYMMETRIX 5874 54007DB000 4417920 /dev/rdsk/c4t5000097*59d6s2 SYMMETRIX 5874 54007DC000 4417920

Cluster Node B also sees thin devices 92A – 92D, but it sees RAID-6 devices 7DD – 7DE:

# syminq -sym Device Product Device ---------------------------------- --------------------- --------------------- Name Type ID Rev Ser Num Cap (KB) ---------------------------------- --------------------- --------------------- /dev/rdsk/c3t5000097*18d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t5000097*18d1s2 SYMMETRIX 5874 540092A000 4417920 /dev/rdsk/c3t5000097*18d2s2 SYMMETRIX 5874 540092B000 4417920 /dev/rdsk/c3t5000097*18d3s2 SYMMETRIX 5874 540092C000 4417920 /dev/rdsk/c3t5000097*18d4s2 SYMMETRIX 5874 540092D000 4417920 /dev/rdsk/c3t5000097*18d5s2 SYMMETRIX 5874 54007DD000 4417920 /dev/rdsk/c3t5000097*18d6s2 SYMMETRIX 5874 54007DE000 4417920 /dev/rdsk/c4t5000097*59d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t5000097*59d1s2 SYMMETRIX 5874 540092A000 4417920 /dev/rdsk/c4t5000097*59d2s2 SYMMETRIX 5874 540092B000 4417920 /dev/rdsk/c4t5000097*59d3s2 SYMMETRIX 5874 540092C000 4417920 /dev/rdsk/c4t5000097*59d4s2 SYMMETRIX 5874 540092D000 4417920 /dev/rdsk/c4t5000097*59d5s2 SYMMETRIX 5874 54007DD000 4417920 /dev/rdsk/c4t5000097*59d6s2 SYMMETRIX 5874 54007DE000 4417920

Removing a masking view and its associated groups

Prior to removing storage, initiator, or port groups, any masking view to which the group is associated must first be removed. This will unmask the devices. The user also has the option to unmap the devices while removing the masking view.

The following steps can be performed to remove the masking view as well as the associated storage, initiator, and port groups:

1. Delete the masking view and, optionally, unmap the devices in the associated storage group.

2. Delete the initiator group.

Page 93: 72361703-smc-autoprovisioning

93

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

3. Delete the port group.

4. Delete the storage group.

Example of deleting a masking view and associated groups

In the following example, the “dbprodsrv_view” masking view will be deleted and the devices in the associated storage group will be unmapped. Following that, the initiator group, port group, and storage group will also be removed:

Step 1 – Delete the masking view and, optionally, unmap the devices in the associated storage group.

The dialog box used to delete views can be accessed by right-clicking on the “dbprodsrv_view” view in the Properties pane, then clicking Device Masking and Mapping > Masking Views Maintenance > Delete Masking View ...

Figure 38 Deleting the masking view

Select the Unmap removed devices checkbox, click OK, and confirm the operation to remove the view.

Page 94: 72361703-smc-autoprovisioning

94

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Figure 39 Unmapping devices

Step 2 – Delete the initiator group.

The dialog box used to delete an initiator group can be accessed by right-clicking on the “dbprodsrv_init” group in the Properties pane, then clicking Device Masking and Mapping > Initiator Groups Maintenance > Delete Initiator Group ...

Page 95: 72361703-smc-autoprovisioning

95

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Figure 40 Deleting an initiator group

Confirm the operation to delete the initiator group:

Figure 41 Confirm the operation

Step 3 – Delete the port group.

The dialog box used to delete a port group can be accessed by right-clicking on the “dbsrv_port” group in the Properties pane, then clicking Device Masking and Mapping > Port Groups Maintenance > Delete Port Group ...

Figure 42 Deleting a port group

Confirm the operation to delete the port group:

Page 96: 72361703-smc-autoprovisioning

96

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Step 4 – Delete the storage group.

The dialog box used to delete a storage group can be accessed by right-clicking on the “dbprod_stor” group in the Properties pane, then clicking Device Masking and Mapping > Storage Groups Maintenance > Delete Storage Group ...

Figure 43 Deleting a storage group

Confirm the operation to delete the storage group:

Page 97: 72361703-smc-autoprovisioning

97

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

Figure 44 Confirm the operation

The view and groups have now been removed:

Figure 45 View and groups are removed

Specifying LUN addresses

SMC assigns dynamic LUNs when device masking is performed. When the devices are mapped to the FA as part of the masking view creation, Symmetrix Enginuity assigns the next available LUNs to the devices in the storage group.

If Set Dynamic LUN Addresses... is clicked when the masking view is created, the devices can be given a range that starts at the specified value. Individual device LUNs can also be modified.

This host currently has only the ACLX device available to it:

Page 98: 72361703-smc-autoprovisioning

98

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

# syminq -sym Device Product Device ---------------------------------- --------------------- --------------------- Name Type ID Rev Ser Num Cap (KB) ---------------------------------- --------------------- --------------------- /dev/rdsk/c3t5000097*18d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c4t5000097*19d0s2 GK SYMMETRIX 5874 5400054000 5760

An initiator group, storage group, and port group have already been created for the host.

A masking view can now be created that will mask and map the devices:

Clicking Set Dynamic LUN Addresses... brings up the Set LUN Addresses dialog box and allows the user to choose a range and also to manually change individual LUN values.

The first two devices in the device list are gatekeepers. It is common to assign gatekeepers high LUN values so that they appear at the end of host or syminq output. In this example, the LUN addresses for the two gatekeepers (0AC and 0AD) have been changed to 0F0 (240) and 0F1 (241):

Page 99: 72361703-smc-autoprovisioning

99

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

After creating the masking view, the devices are available with the specified dynamic LUN addresses:

# syminq -sym Device Product Device ------------------------------------ --------------------- --------------------- Name Type ID Rev Ser Num Cap (KB) ------------------------------------ --------------------- --------------------- /dev/rdsk/c3t5000097*18d0s2 GK SYMMETRIX 5874 5400054000 5760 /dev/rdsk/c3t5000097*18d2s2 M(2) SYMMETRIX 5874 54007B0000 8835840 /dev/rdsk/c3t5000097*18d3s2 SYMMETRIX 5874 54007DB000 4417920 /dev/rdsk/c3t5000097*18d4s2 SYMMETRIX 5874 54007DC000 4417920 /dev/rdsk/c3t5000097*18d5s2 SYMMETRIX 5874 54007DD000 4417920 /dev/rdsk/c3t5000097*18d6s2 SYMMETRIX 5874 54007DE000 4417920 /dev/rdsk/c3t5000097*18d7s2 R1 SYMMETRIX 5874 5400833000 4417920 /dev/rdsk/c3t5000097*18d8s2 R1 SYMMETRIX 5874 5400834000 4417920 /dev/rdsk/c3t5000097*18d9s2 R1 SYMMETRIX 5874 5400835000 4417920 /dev/rdsk/c3t5000097*18d10s2 R1 SYMMETRIX 5874 5400836000 4417920 /dev/rdsk/c3t5000097*18d11s2 SYMMETRIX 5874 5400837000 4417920 /dev/rdsk/c3t5000097*18d12s2 SYMMETRIX 5874 5400838000 4417920 /dev/rdsk/c3t5000097*18d13s2 SYMMETRIX 5874 5400839000 4417920 /dev/rdsk/c3t5000097*18d14s2 SYMMETRIX 5874 540083A000 4417920 /dev/rdsk/c3t5000097*18d15s2 SYMMETRIX 5874 540083B000 4417920 /dev/rdsk/c3t5000097*18d16s2 SYMMETRIX 5874 540083C000 4417920 /dev/rdsk/c3t5000097*18d17s2 SYMMETRIX 5874 540083D000 4417920 /dev/rdsk/c3t5000097*18d18s2 SYMMETRIX 5874 540083E000 4417920 /dev/rdsk/c3t5000097*18d19s2 SYMMETRIX 5874 5400907000 4417920

Page 100: 72361703-smc-autoprovisioning

100

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

/dev/rdsk/c3t5000097*18d20s2 SYMMETRIX 5874 5400908000 4417920 /dev/rdsk/c3t5000097*18d21s2 SYMMETRIX 5874 540092A000 4417920 /dev/rdsk/c3t5000097*18d22s2 SYMMETRIX 5874 540092B000 4417920 /dev/rdsk/c3t5000097*18d23s2 SYMMETRIX 5874 540092C000 4417920 /dev/rdsk/c3t5000097*18d24s2 SYMMETRIX 5874 540092D000 4417920 /dev/rdsk/c3t5000097*18d25s2 M(2) SYMMETRIX 5874 5400ACC000 17675520 /dev/rdsk/c3t5000097*18d240s2 GK SYMMETRIX 5874 54000AC000 5760 /dev/rdsk/c3t5000097*18d241s2 GK SYMMETRIX 5874 54000AD000 5760

Specifying HBA flags

SMC can be used to set port flags on both initiator groups and also on individual host bus adapters within an initiator group. This functionality allows multiple operating systems to share FA ports by moving the flags from the FA port to the HBA or initiator group.

The following flags can be set on the initiator group:

Volume_Set_Addressing [V]

Common_Serial_Number [C]

Disable_Q_Reset_on_UA [D]

Environ_Set [E]

Avoid_Reset_Broadcast [ARB]

AS400 [AS4]

OpenVMS [OVMS]

SCSI_3 [SC3]

SPC2_Protocol_Version [SPC2]

SCSI_Support1 [OS2007]

As the Volume Set Addressing flag affects the LUN addressing scheme in support of HP-UX environments, it can only be set at the initiator group level. The V flag prevents LUNs 8 – F from being assigned to a volume. It is not applicable for any other host environment and must be set on the port or on the initiator group. The V flag can apply to both child and parent initiator groups, but must be consistent across them. If an attempt is made to add an initiator group to another IG to form a cascaded IG and a child group has the V flag set but the parent does not, the command will fail:

Note: In many cases, setting a flag at the group level is preferable to setting it at the initiator level. Setting the flag on the IG propagates the setting to all initiators in the group and guarantees that any initiators added to the group at a later time will inherit the same settings.

To view the current flags set on an initiator group:

Page 101: 72361703-smc-autoprovisioning

101

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

To set the Disable_Q_Reset_on_UA or D flag on an initiator group, right- click the masking view and select Device Mapping and Masking > Initiator Groups Maintenance > Modify Initiator Group….:

Page 102: 72361703-smc-autoprovisioning

102

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Click Set HBA Flags:

Select the flag to set, and check Override and Enable and then click OK on both dialog boxes:

Page 103: 72361703-smc-autoprovisioning

103

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

The Disable_Q_Reset_on_UA is now set on the initiator group and all initiators belonging to it:

Page 104: 72361703-smc-autoprovisioning

104

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

To remove the IG flag that was just set, uncheck both boxes in the Set HBA Flags dialog box and click OK on both dialog boxes.

To set a flag by using the HBA WWN, expand the list of fibre host bus adapters, right-click the chosen WWN, and select Device Masking and Mapping > Set Initiator Attributes:

Page 105: 72361703-smc-autoprovisioning

105

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

In the Set Initiator Attributes dialog box, click Set HBA Flags:

Check both the Override and Enable boxes to enable the D bit:

Page 106: 72361703-smc-autoprovisioning

106

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

Click OK on both dialog boxes. The flag is now set on the HBA:

Page 107: 72361703-smc-autoprovisioning

107

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

To unset the flag on the WWN, uncheck both boxes in the Set HBA Flags dialog box and click OK on both dialog boxes.

Note: There is some dependency between the OS2007 and SPC2 flags. The OS2007 flag can only be set or enabled on the initiator or group when the SPC2 flag is set or enabled on the same initiator or group. The reverse is also true; the SPC2 flag can not be set, disabled, or turned off while the OS2007 flag is set or enabled.

Overriding port flags

Flags that are set on a port can be overridden. In this case, the ports that this host are accessing the Symmetrix has the Common Serial Number (C) flag set. One of the two ports is 7E:0:

# symaccess list hba Identifier Physical Device Path Symmetrix ID Dir:P ---------------- -------------------------------- ------------ ----- 10000000c97683e0 c3t5000097208183D18d160s2 000192601551 07E:0 10000000c97683e1 c4t5000097208183D25d160s2 000192601551 10E:1

Page 108: 72361703-smc-autoprovisioning

108

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

The common serial number flag causes the serial number returned in response to a SCSI inquiry to end in all zeros:

# syminq Device Product Device ---------------------------- --------------------------- --------------------- Name Type Vendor ID Rev Ser Num Cap (KB) ---------------------------- --------------------------- --------------------- /dev/rdsk/c3t5*d0s2 EMC SYMMETRIX 5874 5100278000 4417920 /dev/rdsk/c3t5*d1s2 EMC SYMMETRIX 5874 5100279000 4417920 /dev/rdsk/c3t5*d2s2 EMC SYMMETRIX 5874 510027A000 4417920 /dev/rdsk/c3t5*d3s2 EMC SYMMETRIX 5874 510027B000 4417920 /dev/rdsk/c3t5*d4s2 EMC SYMMETRIX 5874 510027C000 4417920

The IG currently has no port flags set and no port flags overridden:

Page 109: 72361703-smc-autoprovisioning

109

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

The flag cannot simply be turned off at the IG level because the IG is not overriding the flag. It must be turned 'on' at the initiator group to turn on the override of the flag. It can then be disabled so the override action is to unset the flag:

Right-click the initiator group, select Device Mapping and Masking > Initiator Groups Maintenance > Modify Initiator Group. In the Initiator Group Management – Modify dialog box, click Set HBA Flags:

Page 110: 72361703-smc-autoprovisioning

110

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

In the Set HBA Flags dialog box, check Override for the Common Serial Number flag followed by OK at both dialog boxes:

Page 111: 72361703-smc-autoprovisioning

111

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

The C flag is now overridden for the initiators in this IG:

The full serial number, which now includes FA and Port numbers, is

Page 112: 72361703-smc-autoprovisioning

112

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Note

s

now being displayed in syminq output:

# syminq Device Product Device ---------------------------- --------------------------- --------------------- Name Type Vendor ID Rev Ser Num Cap (KB) ---------------------------- --------------------------- --------------------- /dev/rdsk/c3t5*d0s2 EMC SYMMETRIX 5874 5100278470 4417920 /dev/rdsk/c3t5*d1s2 EMC SYMMETRIX 5874 5100279470 4417920 /dev/rdsk/c3t5*d2s2 EMC SYMMETRIX 5874 510027A470 4417920 /dev/rdsk/c3t5*d3s2 EMC SYMMETRIX 5874 510027B470 4417920 /dev/rdsk/c3t5*d4s2 EMC SYMMETRIX 5874 510027C470 4417920

Insuring consistent LUNs across initiators

In some environments, it is a requirement that volumes be given the same LUN value on all channels. To facilitate this, the -consistent LUN option can be used when creating initiator groups:

When the Consistent LUN flag is set on an IG and it is added to a masking view, all volumes in associated storage groups will be assigned

Page 113: 72361703-smc-autoprovisioning

113

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

identical LUNs on all channels as mapping and masking are performed by the Symmetrix.

The Consistent LUN option can apply to both child and parent initiator groups but must be consistent across them. If an attempt is made to add an initiator group to another IG to form a cascaded IG and a child group has the Consistent LUN flag set but the parent does not, the command will fail:

If this occurs, the flag can be set on the child group, which can then be added to the parent IG.

More information about using dynamic LUN addressing can be found in the Symmetrix Dynamic LUN Addressing Technical Note, which is available on Powerlink:

Conclusion

Mapping and masking devices in previous versions of Solutions Enabler required a separate operation for each initiator/port combination through which devices would be accessed. In Solutions Enabler and SMC 7.0 the Autoprovisioning Groups feature allows the user to create a group of devices (storage group), a group of director ports (port group), and a group of host initiators (initiator group), and associate them in a masking view. When the masking view is created, the devices are automatically mapped and masked.

After the masking view is created, any objects (devices, ports, or initiators) added to an existing group automatically become part of the associated masking view. This means that no additional steps are necessary to add additional devices, ports, or initiators to an existing configuration. All necessary operations to make them part of the configuration are handled automatically by Symmetrix Enginuity once the objects are added to the applicable group. This reduces the number of commands needed for mapping and masking devices and allows for easier storage allocation and de-allocation.

Autoprovisioning Groups makes storage allocation easier and faster, especially in modern storage environments where fault-tolerant

Page 114: 72361703-smc-autoprovisioning

114

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

configurations with clustered hosts as well as multiple paths to devices are normally required.

Copyright © 2010 EMC Corporation. All Rights Reserved.

EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice.

THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Use, copying, and distribution of any EMC software described in this publication requires an applicable software license.

For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com.

Page 115: 72361703-smc-autoprovisioning

115

Storage Provisioning With EMC Symmetrix Autoprovisioning Groups

Storage Provisioning With Symmetrix Autoprovisioning Groups Technical Notes

All other trademarks used herein are the property of their respective owners.