Page 1: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance

7083 461-00

ECBN 5066

Installation instructionsfor NoFrost combined refrigerator-freezers

Page 2: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance

2

Setting up• Avoidpositioningtheapplianceindirectsunlightornearcook-ers,radiatorsandsimilarsourcesofheat.

• Theflooronwhichtheappliancestandsshouldbehorizontalandlevel.

• StandardEN378specifiesthattheroominwhichyouinstallyourappliancemusthaveavolumeof1m³per8gofR600arefrigerantusedintheappliance,soastoavoidtheformationofinflammablegas/airmixturesintheroomwheretheapplianceislocatedintheeventofaleakintherefrigerantcircuit.Thequantityofrefrigerantusedinyourapplianceis indicatedonthetypeplateontheinsideoftheappliance.

Electrical connectionOnlyoperatetheappliancewithalternating current (AC).

The permissible voltage and frequency are indicated on thetypeplate.

Thepositionof the typeplate isshown in thesectionentitledDescription of the appliance (in the operating instructions).

Thesocketmustbeproperlyearthedandprotectedbyafuse.

Thetrippingcurrentofthefusemustbebetween10Aand16A.

Thesocketmustnotbesituatedbehindtheappli-anceandmustbeeasilyaccessible.Donotconnecttheapplianceusinganexten-sioncableorextensionsocket.

Donotusestand-aloneinverters(conversionof direct current to alternating/three-phasecurrent)orenergy-savingplugs.Riskofdam-agetotheelectroniccontrolsystem!

Door swing clearance at locations next to a wallPleaseallow fordoorswingclear-anceatlocationsnexttoawall.Theillustratedmeasurementiswith-outmountedfrontpanels.

Besuretoaddyourpanelthicknessandhandledepthtothismeasure-mentinordertoavoidinterferences.

Content PageSettingup................................................................................2Electricalconnection...............................................................2Applianceventing....................................................................2Doorswingclearanceatlocationsnextoawall......................2Appliancedimensions............................................................. 3Installationdimensions............................................................ 3DefinitionofInsetInstallationStyle.........................................4

DefinitionofFramelessInstallationStyle................................4Paneldimensions............................................................................. 4Doorswingclearance..................................................................... 5

Mountingtheanti-tippingdevice............................................. .6Mountingoptions..................................................................... 6Connectiontothewatersupply............................................... .7Waterpressure........................................................................ 7Installation................................................................................7Levelingtheappliance.......................................................... ..9Fasteningtheapplianceintherecess................................... ...9Mountingtheventilationgrille................................................ ...9Adjustingtherefrigeratordoor................................................ 11Adjustingthefrontofthedrawer............................................ .11Removingthemountingaccessoriesfromtherefrigeratordoor....................................................................................... 11Removingthemountingaccessoriesfromthefreezerdrawers.................................................................................. 11Mountingtheattachmentbracketsontothedoorpanels...... .12Mountingtherefrigeratorpanel............................................. .13Mountingthefreezerpanels................................................... 14Changingoverdoorhinges................................................... .14

Appliance ventingTherequiredairflowisdirectedthroughtheplinth.

Itisimportanttousetheprovidedventilationgrillefortheventila-tionopening.

Thisopeningmustnotbecovered.

Page 3: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance

3

Appliance dimensions

A=76mmB=2027mmC=757mmD=610mmE=1413mmF=952mm

Installation dimensionsThelocationofthesocketcanwithinaradiusof2000mmfromtheappliancetopcenter.

Theicemakerisfittedinthefreezercompartmentofthecom-bined refrigerator-freezer. It must be connected to the mainswatersupplytowork.

Thewatershut-offtapmustbepositionedwithintheareasmarkedingrey.

Important!Donotinstalltheshut-offtapbehindtheappliance.

WARNING! The water shut-off tap must not sit directly above the socket!

The gap between the water shut-off tap and the socket must comply with the regulations of the country in which the appliance is used!

This typeof dimensionlineindicatestheheightmeasuredfromthefloor.

Cabinet depth D625 mm + panel thickness>Insetinstallationstyle625 mm>Framelessinstallationstyle

Explanationof"Installationstyles"seepage4.

Page 4: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance
Page 5: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance

5

Rightsidewallofappliancehousing

Frontofappliancehousing

Top View

Frontpanel-doorclosed

Panelthickness

Panelthickness

Frontpanel-dooropeningangle=115°

Door swing clearance

Page 6: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance

6

Mounting the anti-tipping device

WARNING! The supplied anti-tipping bracket must be installed in all cases. This prevents the appli-ance from tipping over when the fully loaded door is opened.

Installation:1. Markthecentrelineoftheapplianceonthefloor.Aligntheanti-tippingbracketcentretothecentreline.

2. Dependingontheconstitutionofthefloorandwall,useanypossiblemountingoptionasshowninchapterMounting Op-tions.Thescrews(6x60)aresuppliedwiththeaccessorypack.

Important!If the floor slopes down sideways, the anti-tipping bracket must be fitted horizontally. Lay down spacers in the appropriate positions.

CAUTION! Ensure that there are no electric cables or water pipes in the wall section to which the anti-tipping bracket is to be secured. These could be damaged during installation.

Mounting options

Wall

Floor

Mountingthebracketwiththewallstuds.Mountingwithplugstoconcretewalls.

3Screws6x60mm

Wall

Floor

Mountingwiththewallplateturninginthescrewsatanangle.

3Screws6x60mm

Wall

Floor

Mountingwithwoodenfloors.

Mountingwithplugstoconcretefloors.

3Screws6x60mm

Page 7: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance

7

3.

4.

3. Insert the bent section of the hosethroughtheopeningattherightsideoftheappliance.

4. Movethehosetothefrontandcon-nectwiththevalveconnector.Be sure the connection is tightlyarranged.

Valve connector

Installation1. Placetheapplianceinfrontoftheinstallationrecess.

2.Applycoverstripsabove,bet-weenandbelowthesecuringplatesonthesidewallsoftheappliance.Cutthecoverstripstotherightlengthforthispurpose.Fittheadhesivecoverstripsleaving a gap of 6,5mm toeach securing plate. Thisensuresproblem-free fittingofthecovers. 2.

Connection to the water supply

Safety instructions and warnings• Do not connect to thewater supplywhile the

combined refrigerator-freezer is connected totheelectricitysupply.• Theconnectiontothemainswatersupplymayonlybemadebytrainedpersonnel.• Thewaterqualitymustcomplywiththedrinkingwaterdirectivesofthecountryinwhichtheap-plianceisused.• Theicemakerisdesignedexclusivelytomakeicecubesinquantitiesrequiredbyahouseholdandmayonlybeoperatedwithwatersuitableforthispurpose.• Allrepairsandworkontheicemakermayonlybecarriedoutbycustomerservicepersonnelorothertrainedpersonnel.• Themanufacturercannotacceptliabilityfordam-agecausedbyafaultyconnectiontothemainswatersupply.

Water pressureThe water pressure must be between 150 and 600 KPa (1.5 - 6 bar).

Important!Ifthewaterfilterisinsertedintheappliance,thewater pressure mustliebetween300 and 600 KPa (3 - 6 bar).

If the water pressure with the inserted water filter is too low, this may cause the ice maker to malfunction.

Thewatersupplytotheappli-ancemustbe throughacoldwaterpipethatcanwithstandthe operating pressure andcomplies with the hygieneregulations.

Forthis,usethestainlesssteelhosesupplied(length3m).

Page 8: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance

8

6. Routethemainscabletowardsthesocket.

7. Routethewaterhosetowardsthewatershut-offtap.

6. 7.

8. Pushtheapplianceslowlyintotherecessuntilthecompressormountingplatetouchestheanti-tippingbracket.

9. Fillthehosewithwaterandconnecttotheshut-offtap.Be sure the connection is tightly arranged.Opentheshut-offtapandcheckthesystemforleakage.

Important!Aftertheicemakerhasbeenswitchedon,thewatersupplysystemmustbebled.

SeethesectionBleeding the ice makerintheop-eratinginstructions.

8.

5. Locatethewaterhoseintotherailoftheappliancebase.

5.

WARNING! Do not connect the appliance to the power supply until the installation is completed.

CAUTION! Lay the mains cable and the water hose in such a way that they will not be damaged when the appliance is slid into the installation recess.

Page 9: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance

9

Mounting the ventilation grillePulloutthebottomfreezerdrawer.

1. Removetheblueprotectionfilmfromthedustfilterprovidedandinsertthefilterintoitsopeningin the plinth. Engage the filter at thebottom,pressdownthebuttonandclickintoplace.

3. Insertthesupportsfortheventilationgrilleontheleftandrightsidesinthemotorcompartment.

2. Remove the locking pins ofbothsupports.Thesupportsare provided with the appli-anceaccessorypack.

1.

2.

3.

Fastening the appliance in the recessOnceintherecess,securetheappliancetothebodyoftheunitusingthesecuringplates(4x16screws).

Thenclickthecoverssup-pliedintoplace.

Leveling the appliance1. Adjusttheheightoftheapplianceatthefrontbytwistingthelevelingfeet1.Usetheopen-endedspannerprovided.Turnthespannercounterclockwisetoraisetheappliancefrontandclockwisetolowerit.Positionthespanneraccordingly(1).

2. Adjusttheheightoftheapplianceattherearbyturningtheadjustingbolts2.Usea1/4"boxspanneror theTorx25wrenchprovided.

3. Rotatelevelingfeet1untilfirmlyinplaceagainstthefloor.

WARNING! To prevent the appliance from tipping forward the leveling feet 1 must have contact with the floor.

Page 10: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance

10

5.

5. Insert the locking pins to block thesupports.

6. Installtheventilationgrille.Thegrillehasboltsontheinside(seedetail inthedrawingbelow).Theseboltsmustbe inserted into theholesof thesupports.

4. Thefrontedgeofthebracketsis flush with the front of theventilationgrille.Adjustthesupportsaccordingly.

7. Adjusttheheightoftheventilationgrille.• Loosen thegrubscrewsat the frontof thegrille (AllenkeyA/F2.5).

• Adjusttheventilationgrilletothedesiredheight.• Tightenthegrubscrews.

7.

4.

6.

Page 11: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance

11

Removing the mounting accessories from the refrigerator doorRemovethecover1andunscrewthetopandbottomattach-mentbrackets2fromtherefrigeratordoor.Theseattachmentbracketswillbemountedontotherefrigeratordoorpanel.

Important!The securing nuts are needed for re-mounting the pre-assembled door panel onto the refrigerator door.

Removing the mounting accessories from the freezer drawersUnscrewtheattachmentbrackets3fromthefreezerdrawers.These attachment bracketswill bemounted onto the freezerpanels.

Important!The screws are needed for re-mounting the pre-assembled freezer panels onto the freezer drawers.

Adjusting the refrigerator doorThelateraltiltoftherefrigeratordoorcanbeadjustedifrequired.Undoscrews1.Adjustthelateraltiltusingthegrubscrew2 (AllenkeyA/F2.5).

Adjusting the front of the drawerIfrequired,thefrontofthefreezerdrawerscanbeadjusted.Transferthescrewsshownintheillustration(ontheleftandrightsidesofthefreezerdrawer)individuallytothelongslotsbelow.Tighten thescrews in the frontof thedraweronce it is in therightposition.

Side view of the freezer drawer pulled out

Page 12: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance

12

Mounting the attachment brackets onto the door panels

1. Drawaline1041mmfromthebottomsideofthedoorpanel.

2. Drawafurtherline107.5mmfromthebottomsideofthedoorpanel.3. Alignoneoftherefrigeratordoorattachmentbracketstothetopline,asshownintheillustrationbelow,andsecurewithatleast6screws(4x14).

4. Alignthesecondrefrigeratordoorattachmentbrackettothebottomline,asshownintheillustrationbelow,andsecurewithatleast6screws(4x14).

5. Secureeachoftheattachmentbracketsthathavebeenremovedfromthefreezerdrawersusing3screws(4x14),asshownintheillustrationbelow.

Refrigeratordoorpanel

Freezerdrawerpanel

Freezerdrawerpanel

Page 13: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance

13

fig. D

Mounting the refrigerator panel

fig. A

fig. B

fig. C

1. Screw in theadjustingpinsontheundersideoftherefrigeratordoorcompletely(fig. A).

2. Opentherefrigeratordoorandsus-pendtherefrigeratorpanelonthetopadjustingpins(fig. B).

3. Screwsecuringnutsontotheadjust-ingpinsandslightlytighten.

4. Closetherefrigeratordoorandchecktheheightofthepanel.

5. Adjust theheight of thepanel if necessary.Undothesecuringnutsandusetheadjustingpinstoadjust(fig. C).

6. Adjustthepanelhorizon-tally(usingthelongslotsintheattachmentbracket)(fig. D).

7. Tightenthesecuringnuts.

fig. E

fig. F

8. Removetheadjustingpins(bottomof the refrigeratordoor)untilthesetouchtheattachmentbracket(fig. E).

9. Screwonthesecuringnutsandtighten(fig. F).

Page 14: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance

14

Mounting the freezer panels1. Pulloutthetopfreezerdrawerandscrewonthepre-assembledpanel.Thesamescrewsmustbeusedasthoseusedtoscrewontheattachmentbrackets(3.5x13).

2. Closethefreezerdrawerandcheckthepositionofthepanel.Adjust theheightof thepanelbyundoingthe leftandrightscrews.Tightenthescrews.

3.Pulloutthebottomfreezerdrawerandmountthepanelinthesameway.

4. Forbothdrawers,coverthegapbetweenthedrawerandthepanelwiththecoverstripssupplied.Removetheprotectivefilmfromthetrimandinsertintothegapatthetop.

3.5x13mm

Changing over door hingesDoorhingesshouldonlybechangedbyatrainedexpert.

WARNING! Do not try to change over the door hinges your-self. The refrigerator door hinges are fitted with strong closing springs. If the hinge accidentally snaps shut, this can lead to serious injury.

11. Clickthetopandbottomcoversintoplace1 (fig. H)Insertthecoverstripprovided2betweenrefrigeratordoorandpanel.

fig. H

fig. G

10. Undothethreescrewsonthetopoftheattach-mentbracket,adjustthedoorpanelasdisplayedin fig. Gandthenretightenthescrews.Thesameprocedure can be carried out for the bottomattachmentbracket.

Page 15: 7083 461-00 - Andi-Co Australia Pty Ltd · 7083 461-00 ECBN 5066 Installation instructions for NoFrost combined refrigerator-freezers . 2 Setting up •Avoid positioning the appliance

LiebherrHausgeräteLienzGmbH*Dr.-Hans-Liebherr-Strasse1*A-9900Lienz**www.liebherr.com