Power Supply ComponentsLM-0.5 Series Low Voltage CurrentTransformer

Confirms to: Primary amps-turn: 50A~6000ASecondary current: 1A, 5ARated voltage: 0.5kVRated capacity: 2.5VA~10VAAccuracy: 1.0, 0.5, 0.2Primary winding: generatrix

IEC60044-1

MSQ Series Low Voltage CurrentTransformer

Confirms to: IEC60044-1

Rated test voltage: 3KV AC(1min)

Rated short-time thermal current(Ith): 60In

Rated dynamic current(Idyn): 2.5Ith

Rated voltage: 0.72KV AC

Secondary current: 5A/1A

Rated frequency: 50/60Hz

Primary winding: generatrix or bus-bar

LMZ(J)-0.5 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 50A~6000ASecondary current: 1A, 5ARated voltage: 0.5kVRated capacity: 2.5VA~15VAAccuracy: 1.0, 0.5, 0.2, 0.5S, 0.2SPrimary winding: generatrix or bus-bar

IEC60044-1

LMZ(J)1-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 50A~6000ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 1.0, 0.5, 0.2, 0.5S, 0.2SPrimary winding: generatrix or bus-bar

IEC60044-1

LMZ3-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 150A~3000ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 0.5, 0.2Primary winding: generatrix or bus-bar

IEC60044-1

LMK1-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 50A~5000ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 1.0, 0.5, 0.2, 0.5S, 0.2SPrimary winding: generatrix or bus-bar

IEC60044-1

LMK2-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 50A~5000ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 1.0, 0.5, 0.2, 0.5S, 0.2SPrimary winding: bus-bar

IEC60044-1

LMK3-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 150A~2000ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 0.5Primary winding: generatrix

IEC60044-1

051 www.peopleelectric.com

Power Supply Components

Power Supply ComponentsLM-0.5 Series Low Voltage CurrentTransformer

Confirms to: Primary amps-turn: 50A~6000ASecondary current: 1A, 5ARated voltage: 0.5kVRated capacity: 2.5VA~10VAAccuracy: 1.0, 0.5, 0.2Primary winding: generatrix

IEC60044-1

MSQ Series Low Voltage CurrentTransformer

Confirms to: IEC60044-1

Rated test voltage: 3KV AC(1min)

Rated short-time thermal current(Ith): 60In

Rated dynamic current(Idyn): 2.5Ith

Rated voltage: 0.72KV AC

Secondary current: 5A/1A

Rated frequency: 50/60Hz

Primary winding: generatrix or bus-bar

LMZ(J)-0.5 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 50A~6000ASecondary current: 1A, 5ARated voltage: 0.5kVRated capacity: 2.5VA~15VAAccuracy: 1.0, 0.5, 0.2, 0.5S, 0.2SPrimary winding: generatrix or bus-bar

IEC60044-1

LMZ(J)1-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 50A~6000ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 1.0, 0.5, 0.2, 0.5S, 0.2SPrimary winding: generatrix or bus-bar

IEC60044-1

LMZ3-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 150A~3000ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 0.5, 0.2Primary winding: generatrix or bus-bar

IEC60044-1

LMK1-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 50A~5000ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 1.0, 0.5, 0.2, 0.5S, 0.2SPrimary winding: generatrix or bus-bar

IEC60044-1

LMK2-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 50A~5000ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 1.0, 0.5, 0.2, 0.5S, 0.2SPrimary winding: bus-bar

IEC60044-1

LMK3-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 150A~2000ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 0.5Primary winding: generatrix

IEC60044-1

051 www.peopleelectric.com

Power Supply Components

LMK4-0.66 Series Low Voltage CurrentTransformer

Confirms to: Primary amps-turn: 150A~5000ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 1.0, 0.5, 0.2, 0.5S, 0.2SPrimary winding: generatrix or bus-bar

IEC60044-1

LMK5-0.66 Series Low Voltage CurrentTransformer

Confirms to: Primary amps-turn: 150A~6300ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~10VAAccuracy: 1.0, 0.5, 0.2, 0.5S, 0.2SPrimary winding: generatrix or bus-bar

IEC60044-1

LMK6-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 300A~6300ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 0.5, 0.2, 0.5S, 0.2SPrimary winding: bus-bar

IEC60044-1

LMK7-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 300A~6300ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 0.5, 0.2, 0.5S, 0.2SPrimary winding: bus-bar

IEC60044-1

LMK8-0.66 Series Low Voltage Current Transformer

Confirms to: M typePrimary current: 5A~100APrimary winding: Bolt connection generatrix or bus-barφ typePrimary current: 150A~400APrimary winding: generatrixRated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 0.5, 0.2Primary winding: generatrix or bus-bar

IEC60044-1

LMK9-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 300A~6300ASecondary current: 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 5P15, 10P15Primary winding: bus-barInstallation requirements: Indoor, fixed on the bus-barby fastening the screw

IEC60044-1

JDG-0.5 Series Low Voltage Current Transformer

Rated frequency: 50/60Hz

Rated voltage: 0.5kV

Insulation voltage: 3kV

Accuracy: 3.0, 1.0, 0.5

LJ Series Low Voltage Zero Sequency Current Transformer

Rated frequency: 50/60Hz

Rated voltage: 500V

Cable pcs/diameter of hole: 1/φ75, 2/φ110, 4/φ140, 7/φ185

JBK Series Control Transformer

Confirms to: JB/T 5555, IEC60044-1

Single-phase or two phase 50Hz/60Hz

Selectable scope of rated operating voltage: ≤660V

( it can be customized when >660V or ≤1140V)

BK Series Control Transformer

Confirms to: JB/T 5555, IEC60044-1

Single-phase or two phase 50/60Hz

Selectable scope of rated operating voltage: ≤660V

( it can be customized when >660V or ≤1140V)

It can long- term operation under the rated load

BKC Series Control Transformer

Confirms to: JB/T 5555, IEC60044-1

Single-phase or two phase 50/60Hz

Selectable scope of rated operating voltage: ≤660V

( it can be customized when >660V or ≤1140V)

It can long- term operation under the rated load

Adopts the iron core of “C” shape structure as well

as installation foot that is formed by once time

BKZ Series Rectification Transformer

Confirms to: JB/T 5555, IEC60044-1

Single-phase or two phase 50/60Hz

Selectable scope of rated operating voltage: ≤660V

( it can be customized when >660V or ≤1140V)

It is mainly consisted of control transformer, silicon

rectifier as well as the terminals.

JMB (DG, BJZ, BZ) Series LightingTransformer

Confirms to: JB/T 5555, IEC60044-1

Single-phase or two phase 50/60Hz

Selectable scope of rated operating voltage: ≤660V

It can long- term operation under the rated load

QZB Series Auto-Coupling Transformer

Confirms to: GB 14048.4, JB/T8752

Rated voltage: AC 380V, 220V, 660V

Rated frequency: 50/60Hz

Three phase squirrel cage induction motor step-down startup for 500kW and below

SG (SBK, ZSG) Series Three phaseDry-Type Transformer

Confirms to: JB/T 8750

Three phase 50/60Hz

Selectable scope of rated operating voltage: ≤690VIt can long- term operation under the rated load

BP1-3 Series Frequency SensitiveRheostat

It is suitable for the light load or heavy and light load of three phase AC winding asynchronous motor thatcapacity is 2.2kW~2240kW, as the use of startup.

053 www.peopleelectric.com www.peopleelectric.com 052

Power Supply Components

LMK4-0.66 Series Low Voltage CurrentTransformer

Confirms to: Primary amps-turn: 150A~5000ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 1.0, 0.5, 0.2, 0.5S, 0.2SPrimary winding: generatrix or bus-bar

IEC60044-1

LMK5-0.66 Series Low Voltage CurrentTransformer

Confirms to: Primary amps-turn: 150A~6300ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~10VAAccuracy: 1.0, 0.5, 0.2, 0.5S, 0.2SPrimary winding: generatrix or bus-bar

IEC60044-1

LMK6-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 300A~6300ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 0.5, 0.2, 0.5S, 0.2SPrimary winding: bus-bar

IEC60044-1

LMK7-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 300A~6300ASecondary current: 1A, 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 0.5, 0.2, 0.5S, 0.2SPrimary winding: bus-bar

IEC60044-1

LMK8-0.66 Series Low Voltage Current Transformer

Confirms to: M typePrimary current: 5A~100APrimary winding: Bolt connection generatrix or bus-barφ typePrimary current: 150A~400APrimary winding: generatrixRated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 0.5, 0.2Primary winding: generatrix or bus-bar

IEC60044-1

LMK9-0.66 Series Low Voltage Current Transformer

Confirms to: Primary amps-turn: 300A~6300ASecondary current: 5ARated voltage: 0.66kVRated capacity: 5VA~15VAAccuracy: 5P15, 10P15Primary winding: bus-barInstallation requirements: Indoor, fixed on the bus-barby fastening the screw

IEC60044-1

JDG-0.5 Series Low Voltage Current Transformer

Rated frequency: 50/60Hz

Rated voltage: 0.5kV

Insulation voltage: 3kV

Accuracy: 3.0, 1.0, 0.5

LJ Series Low Voltage Zero Sequency Current Transformer

Rated frequency: 50/60Hz

Rated voltage: 500V

Cable pcs/diameter of hole: 1/φ75, 2/φ110, 4/φ140, 7/φ185

JBK Series Control Transformer

Confirms to: JB/T 5555, IEC60044-1

Single-phase or two phase 50Hz/60Hz

Selectable scope of rated operating voltage: ≤660V

( it can be customized when >660V or ≤1140V)

BK Series Control Transformer

Confirms to: JB/T 5555, IEC60044-1

Single-phase or two phase 50/60Hz

Selectable scope of rated operating voltage: ≤660V

( it can be customized when >660V or ≤1140V)

It can long- term operation under the rated load

BKC Series Control Transformer

Confirms to: JB/T 5555, IEC60044-1

Single-phase or two phase 50/60Hz

Selectable scope of rated operating voltage: ≤660V

( it can be customized when >660V or ≤1140V)

It can long- term operation under the rated load

Adopts the iron core of “C” shape structure as well

as installation foot that is formed by once time

BKZ Series Rectification Transformer

Confirms to: JB/T 5555, IEC60044-1

Single-phase or two phase 50/60Hz

Selectable scope of rated operating voltage: ≤660V

( it can be customized when >660V or ≤1140V)

It is mainly consisted of control transformer, silicon

rectifier as well as the terminals.

JMB (DG, BJZ, BZ) Series LightingTransformer

Confirms to: JB/T 5555, IEC60044-1

Single-phase or two phase 50/60Hz

Selectable scope of rated operating voltage: ≤660V

It can long- term operation under the rated load

QZB Series Auto-Coupling Transformer

Confirms to: GB 14048.4, JB/T8752

Rated voltage: AC 380V, 220V, 660V

Rated frequency: 50/60Hz

Three phase squirrel cage induction motor step-down startup for 500kW and below

SG (SBK, ZSG) Series Three phaseDry-Type Transformer

Confirms to: JB/T 8750

Three phase 50/60Hz

Selectable scope of rated operating voltage: ≤690VIt can long- term operation under the rated load

BP1-3 Series Frequency SensitiveRheostat

It is suitable for the light load or heavy and light load of three phase AC winding asynchronous motor thatcapacity is 2.2kW~2240kW, as the use of startup.

053 www.peopleelectric.com www.peopleelectric.com 052

Power Supply Components

BP4 Series Rheostat

Frequency Sensitive

It is suitable for the 14kW~1000kW winding

asynchronous induction motor, as the use

of heavy load startup.

BP6 Series Rheostat

Frequency Sensitive

It is suitable for three phases AC 50Hz winding

asynchronous motor, as the use of full load startup.

BP8Y Series Rheostat

Frequency Sensitive

It is suitable for the use of startup and reverse

connection of 1.5kW~1000kW 50Hz new type

energy saving motor, YZR series lifting metallurgy

asynchronous motor, under the situation of

frequently and sensitive operation.

ZX9 Series Rheostat

Rated voltage: up to AC 660V, DC up to 440V

Total resistance value: 0.106Ω~7.396Ω

Allowed load current: 24A~215A

ZX12 Series Rheostat

Rated voltage: up to AC 660V, DC up to 440V

Total resistance value: 0.1Ω~8.0Ω

Allowed load current: 24A~215A

ZX15 Series Rheostat

Rated voltage: up to AC 660V, DC up to 440V

Total resistance value: 0.10Ω~11.0Ω

Allowed load current: 20A~215A

RT, RK Series Rheostat

Rated capacity: 0.6kW~30kW

Voltage of wheel: 64V~285V

Current of wheel: 8.15A~67A

XD1 Series Limit Current Rheostat

Confirms to: GB10229

Frame size: 12, 20

Suited capacitor: 12kvar~40kvar

Operating voltage: 0.4kV

Continuous current: 22.5A~76A

Installation requirements: Indoor, fasten by screw

ACL Series Incoming Line Reactor

Rated current: 8A~1000A

Voltage drop: 2.3V, 5V, 9V

Suited power: 0.75 (1.5)kW~400kW

Insulation grade: F, H

OCL Series Outgoing Line Reactor

Rated current: 8A~1000A

Voltage drop: 2.3V, 5V, 9V

Suited power: 0.75 (1.5)kW~400kW

Insulation grade: F, H

DCL Series DC Flat Wave Reactor

Rated current: 3A~1500A/40℃

Rated operating voltage: 400V~1200V/50Hz

Dielectric withstanding voltage: iron core-winding

3000VAC/50Hz/10Ma/10s without puncture

Suited power: 0.75 (1.5)kW~400kW

Insulation grade: F, H

CKSG Series Connection Reactor

Low Voltage Series

Reactance rate: 1%, 4.5%, 5%, 5.67%, 6%, 7%

12%, 13.8%, 14%

Rated voltage: 0.4kV~35kV

Insulation grade: B, F, H

CKSC Series Connection Reactor

Low Voltage Series

Reactance rate: 1%, 4.5%, 5%, 5.67%, 6%, 7%

12%, 13.8%, 14%

Rated voltage: 0.4kV~0.69kV

Insulation grade: B, F, H

CKGKL Series Hollow Reactor

Rated voltage: 6kV~35kV

Rated capacity: 0~3500kvar

TDGC, TSGC, TDGC2, TSGC2 SeriesVoltage Regulator

Confirms to: JB/T8749.3

Phase: Single phase, Three phase

Input voltage: single phase 220V, three phase 380V

Output voltage: single phase 0~250V, three phase 0~430V

Rated current: 2A~120A

SVC (TND, TNS) Series AC VoltageStabilizer

Confirms to: JB/T10089

Phase: Single phase, Three phase

Input voltage: 160V~250V, 280V~430V

Output voltage: 380V (1±3%)

Accuracy of voltage stabilization: ±3%

Output over voltage protective value:

246±4V, 426±7V

SVC-II Series AC Voltage Stabilizer

Confirms to: JB/T10089

Phase: Single phase

Input voltage: 130V~260V

Output voltage: 220V (1±3%)

Rated current: 2.2A~72A

Accuracy of voltage stabilization: ±3%

Output over voltage protective value:

246±4V

055 www.peopleelectric.com www.peopleelectric.com 054

Power Supply Components

BP4 Series Rheostat

Frequency Sensitive

It is suitable for the 14kW~1000kW winding

asynchronous induction motor, as the use

of heavy load startup.

BP6 Series Rheostat

Frequency Sensitive

It is suitable for three phases AC 50Hz winding

asynchronous motor, as the use of full load startup.

BP8Y Series Rheostat

Frequency Sensitive

It is suitable for the use of startup and reverse

connection of 1.5kW~1000kW 50Hz new type

energy saving motor, YZR series lifting metallurgy

asynchronous motor, under the situation of

frequently and sensitive operation.

ZX9 Series Rheostat

Rated voltage: up to AC 660V, DC up to 440V

Total resistance value: 0.106Ω~7.396Ω

Allowed load current: 24A~215A

ZX12 Series Rheostat

Rated voltage: up to AC 660V, DC up to 440V

Total resistance value: 0.1Ω~8.0Ω

Allowed load current: 24A~215A

ZX15 Series Rheostat

Rated voltage: up to AC 660V, DC up to 440V

Total resistance value: 0.10Ω~11.0Ω

Allowed load current: 20A~215A

RT, RK Series Rheostat

Rated capacity: 0.6kW~30kW

Voltage of wheel: 64V~285V

Current of wheel: 8.15A~67A

XD1 Series Limit Current Rheostat

Confirms to: GB10229

Frame size: 12, 20

Suited capacitor: 12kvar~40kvar

Operating voltage: 0.4kV

Continuous current: 22.5A~76A

Installation requirements: Indoor, fasten by screw

ACL Series Incoming Line Reactor

Rated current: 8A~1000A

Voltage drop: 2.3V, 5V, 9V

Suited power: 0.75 (1.5)kW~400kW

Insulation grade: F, H

OCL Series Outgoing Line Reactor

Rated current: 8A~1000A

Voltage drop: 2.3V, 5V, 9V

Suited power: 0.75 (1.5)kW~400kW

Insulation grade: F, H

DCL Series DC Flat Wave Reactor

Rated current: 3A~1500A/40℃

Rated operating voltage: 400V~1200V/50Hz

Dielectric withstanding voltage: iron core-winding

3000VAC/50Hz/10Ma/10s without puncture

Suited power: 0.75 (1.5)kW~400kW

Insulation grade: F, H

CKSG Series Connection Reactor

Low Voltage Series

Reactance rate: 1%, 4.5%, 5%, 5.67%, 6%, 7%

12%, 13.8%, 14%

Rated voltage: 0.4kV~35kV

Insulation grade: B, F, H

CKSC Series Connection Reactor

Low Voltage Series

Reactance rate: 1%, 4.5%, 5%, 5.67%, 6%, 7%

12%, 13.8%, 14%

Rated voltage: 0.4kV~0.69kV

Insulation grade: B, F, H

CKGKL Series Hollow Reactor

Rated voltage: 6kV~35kV

Rated capacity: 0~3500kvar

TDGC, TSGC, TDGC2, TSGC2 SeriesVoltage Regulator

Confirms to: JB/T8749.3

Phase: Single phase, Three phase

Input voltage: single phase 220V, three phase 380V

Output voltage: single phase 0~250V, three phase 0~430V

Rated current: 2A~120A

SVC (TND, TNS) Series AC VoltageStabilizer

Confirms to: JB/T10089

Phase: Single phase, Three phase

Input voltage: 160V~250V, 280V~430V

Output voltage: 380V (1±3%)

Accuracy of voltage stabilization: ±3%

Output over voltage protective value:

246±4V, 426±7V

SVC-II Series AC Voltage Stabilizer

Confirms to: JB/T10089

Phase: Single phase

Input voltage: 130V~260V

Output voltage: 220V (1±3%)

Rated current: 2.2A~72A

Accuracy of voltage stabilization: ±3%

Output over voltage protective value:

246±4V

055 www.peopleelectric.com www.peopleelectric.com 054

Power Supply Components

TSD Series AC Voltage StabilizerConfirms to: JB/T10089

Phase: single phase

Input voltage: 150V~250V

Output voltage: 220V (1±3%)

Rated current: 13.5A~32A

Accuracy of voltage stabilization: ±3%

Output over voltage protective value:

246±4V

DBW, SBW Series AC Voltage StabilizerConfirms to: JB/T7620

Phase: single phase, three phase

Input voltage: 220V(1±20%), 380V(1±20%)

Output voltage: 220V (1±3%),380V(1±3%)

Accuracy of voltage stabilization: ±3%

Output over voltage protective value:

242±2.2V,418±3.8V

Output undervoltage protective value:

198±2.2V, 342±3.8V

(D)SBW-C Series Power VoltageStabilizer

Confirms to: JB/T7620

Phase: single phase, three phase

Input voltage: 220V(1±20%), 380V(1±20%)

Output voltage: 220V (1±3%),380V(1±3%)

Accuracy of voltage stabilization: ±3%

Output over voltage protective value:

242±2.2V,418±3.8V

Output undervoltage protective value:

198±2.2V, 342±3.8V

AVR Series AC Voltage Stabilizer

Confirms to: JB/T10266

Phase: single phase

Input voltage: AC160V~260V

Output voltage: 220V (1±8

Rated current: 2.2A~45.5A

Accuracy of voltage stabilization: ±8%

Over voltage protective value: 246±4V

Undervoltage protective value:184±4V

%)

JJW, JSW Series Precision Purify ACVoltage Stabilizer

Confirms to: JB/T9299

Phase: single phase, three phase

Scope of voltage stabilization: single phase 185V~250V,

three phase 320V~433V

Output voltage: 220V (1±1 ,380V(1±1

Over voltage protective value: output voltage 246±4V

Output wave distortion

%) %)

UPS Series

Rated power: 1kVA/0.7kW~6kVA/4.2kW

Frequency: 50Hz

Input voltage: AC 180V~300V, AC 176V~276V

Input current: 5A~30A

Output voltage: AC220V

Output current: 4.5A~27A

EPS Series Emergency Power Supply

Capacity: 0.5kW~150kW

Frequency: 50Hz±3Hz

Rated voltage: DC 55V/216V, DC216V, DC324V

Charging time: less than 22h

Protective functions: over-load, short-circuit, under-

voltage (removable) protections

Over load capacity: 120% (30s), 150% (10s)

Emergency switching: <5s (important occasion 0.25s)

S, D, T, Q Series Switching ModePower Supply

Input voltage: AC 85~264, 47~63HzDC 120~370VImpact current: cooling startup current 15A/110V, 30A/230VOver load protection: 105~150% closing current, and auto-recoveryOver voltage protection: 115%~135% of output voltage

www.peopleelectric.com 056