7 installation over the range instructions microwave oven · or visit our website at: read...

24
or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven Read these instructions completely and carefully. IMPORTANT – Save these instructions for local inspector’s use. IMPORTANT – Observe all governing codes and ordinances. Note to Installer – Be sure to leave these instructions with the Consumer. BEFORE YOU BEGIN Note to Consumer – Keep these instructions for future reference. Skill level – Installation of this appliance requires basic mechanical and electrical skills. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Warranty. 7 http://www.frigidaire.com 1-800-944-9044(US) Questions? Call 1-800-668-4606(Canada)

Upload: others

Post on 18-Sep-2019

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

or Visit our Website at:

READ CAREFULLY.

KEEP THESE INSTRUCTIONS.

Installation Over the RangeInstructions Microwave Oven

Read these instructions completely and carefully.

• IMPORTANT – Save these instructions for local inspector’s use.

• IMPORTANT – Observe all governing codes and ordinances.

• Note to Installer – Be sure to leave theseinstructions with the Consumer.

BEFORE YOU BEGIN• Note to Consumer – Keep these

instructions for future reference.• Skill level – Installation of this appliance requires

basic mechanical and electrical skills.• Proper installation is the responsibility of the installer. • Product failure due to improper installation is not

covered under the Warranty.

7

http://www.frigidaire.com1-800-944-9044(US)Questions? Call 1-800-668-4606(Canada)

Page 2: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

2

Recirculating ........................................ 19–22

Attach Mounting Plate to Wall ............19

Preparation of Top Cabinet ................19

Check Microwave Assembly ................20

Adapting Microwave Blower for Recirculation ..........................20, 21

Mount the Microwave Oven ..........21, 22

Installing the Charcoal Filter ..............22

Before You Use Your Microwave .......................... 23

CONTENTS

General information

Important Safety Instructions .................................. 3

Electrical Requirements .......................................... 3

Hood Exhaust ...................................................... 4, 5

Damage – Shipment/Installation.............................. 6

Parts Included.......................................................... 6

Tools You Will Need ................................................ 7

Mounting Space ...................................................... 7

Step-by-step installation guide

Placement of Mounting Plate ............................ 8–10

Removing the Mounting Plate ...................... 8

Finding the Wall Studs .................................. 8

Determining Wall Plate Location .................. 9

Aligning the Wall Plate................................ 10

Installation Types.............................................. 11–22

Outside Top Exhaust ............................ 12–14

Attach Mounting Plate to Wall ............12

Preparation of Top Cabinet ................13

Checking for Proper DamperOperation ............................................13

Mount the Microwave Oven ..........13, 14

Adjust the Exhaust Adaptor ................14

Connecting Ductwork..........................14

Outside Back Exhaust ............................ 15–18

Preparing Rear Wall for Outside Back Exhaust ..........................15

Remove Exhaust Adaptor ......................15

Attach Mounting Plate to Wall ............16

Preparation of Top Cabinet ................16

Adapting Microwave Blowerfor Outside Back Exhaust................16, 17

Mount the Microwave Oven ................18

A

B

C

Installation Instructions

Page 3: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

This product requires a three-prong grounded outlet.The installer must perform a ground continuity check on the power outlet box before beginning the installation to insure that the outlet box is properlygrounded. If not properly grounded, or if the outlet box does not meet electrical requirements noted (under ELECTRICAL REQUIREMENTS), a qualifiedelectrician should be employed to correct anydeficiencies.

CAUTION: For personal safety, remove house fuse or open circuit breaker before beginning installation to avoid severe or fatal shock injury.

CAUTION: For personal safety, the mounting surface must be capable of supporting the cabinet load, in addition to the added weight of this 63–85 pound(28.5–38.5 kg) product, plus additional oven loads ofup to 50 pounds (22.7 kg) or a total weight of113–135 pounds (51.3–61.2 kg).

CAUTION: For personal safety, this product cannot be installed in cabinet arrangements such as an island or a peninsula. It must be mounted to BOTH a top cabinet AND a wall.

NOTE: For easier installation and personal safety, it is recommended that two people install this product.IMPORTANT – PLEASE READ CAREFULLY. FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED TO AVOID SEVERE OR FATAL SHOCK.

The power cord of thisappliance is equipped with a three-prong (grounding) plug which mates with a standard three-prong (grounding) wall receptacle to minimize the possibility of electric shock hazard from this appliance.

You should have the wall receptacle and circuit checkedby a qualified electrician to make sure the receptacle isproperly grounded.

Where a standard two-prong wall receptacle is encountered, it is very important to have it replaced with a properly grounded three-prong wall receptacle,installed by a qualified electrician.

DO NOT, UNDER ANY CIRCUMSTANCES, CUT,DEFORM OR REMOVE ANY OF THE PRONGS FROM THE POWER CORD. DO NOT USE WITH AN EXTENSION CORD.

IMPORTANT SAFETY INSTRUCTIONS

3

ELECTRICALREQUIREMENTSProduct rating is 120 volts AC, 60 Hertz, 15 amps and1.6 kilowatts. This product must be connected to asupply circuit of the proper voltage and frequency.Wire size must conform to the requirements of theNational Electrical Code or the prevailing local code for this kilowatt rating. The power supply cord and plug should be brought to a separate 15- to 20- ampere branch circuit single groundedoutlet. The outlet box should be located in thecabinet above the microwave oven. The outlet boxand supply circuit should be installed by a qualifiedelectrician and conform to the National ElectricalCode or the prevailing local code.

Ensure properground existsbefore use

Installation Instructions

Page 4: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

4

EQUIVALENT NUMBER EQUIVALENT

DUCT PIECES LENGTH x USED = LENGTH

Roof Cap 24 Ft. (7.3 m) x (1) = 24 Ft. (7.3 m)

12 Ft. (3.6 m) Straight Duct 12 Ft. (3.6 m) x (1) = 12 Ft. (3.6 m)(6”/15.2 cm Round)

Rectangular-to-Round 5 Ft. (1.5 m) x (1) = 5 Ft. (1.5 m)Transition Adaptor*

Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any vent hood.

Total Length = 41 Ft. (12.5 m)

HOOD EXHAUST

The following chart describes an example of one possibleductwork installation.

NOTE: Read these next two pages only if you plan to vent your exhaust to theoutside. If you plan to recirculate the air back into the room, proceed to page 6.

OUTSIDE TOP EXHAUST (EXAMPLE ONLY)

NOTE: For back exhaust, care should be taken to align exhaust with space between studs, or wall should be preparedat the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.

* IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will have to be cut to fit, using the tin snips, in order to allow free movement of the damper.

The following chart describes an example of one possibleductwork installation.

Installation Instructions

OUTSIDE BACK EXHAUST (EXAMPLE ONLY)

EQUIVALENT NUMBER EQUIVALENT

DUCT PIECES LENGTH* x USED = LENGTH

Wall Cap 40 Ft. (12.2 m) x (1) = 40 Ft. (12.2 m)

3 Ft. Straight Duct 3 Ft. (0.9 m) x (1) = 3 Ft. (0.9 m)(31⁄4” x 10”/8.2 x 25.4 cmRectangular)

90° Elbow 10 Ft. (3 m) x (2) = 20 Ft. (3 m)

Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any vent hood.

Total Length = 63 Ft. (19.2 m)

Page 5: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

EQUIVALENT NUMBER EQUIVALENT

DUCT PIECES LENGTH x USED = LENGTH

Rectangular-to-Round 5 Ft. (1.5 m) x ( ) = Ft. or mTransition Adaptor*

Wall Cap 40 Ft. (12.2 m) x ( ) = Ft. or m

90° Elbow 10 Ft. (3 m) x ( ) = Ft. or m

45° Elbow 5 Ft. (1.5 m) x ( ) = Ft. or m

90° Elbow 25 Ft. (7.6 m) x ( ) = Ft. or m

45° Elbow 5 Ft. (1.5 m) x ( ) = Ft. or m

Roof Cap 24 Ft. (7.3 m) x ( ) = Ft. or m

Straight Duct 6“ (15.2 cm) 1 Ft. (0.3 m) x ( ) = Ft. or mRound or 31⁄4“ x 10“(8.2 x 25.4 cm) Rectangular

Total Ductwork = Ft. or m

Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any vent hood.

* IMPORTANT: If a rectangular-to-round transitionadaptor is used, the bottom corners of the damperwill have to be cut to fit, using the tin snips, in orderto allow free movement of the damper.

NOTE: If you need to install ducts, note that the totalduct length of 31⁄4” x 10” (8.2 x 25.4 cm) rectangular or6” (15.2 cm) diameter round duct should not exceed120 equivalent feet (36.5 m).Outside ventilation requires a HOOD EXHAUST DUCT.Read the following carefully.NOTE: It is important that venting be installed using the most direct route and with as few elbows as possible. This ensures clear venting of exhaust and helps preventblockages. Also, make sure dampers swing freely andnothing is blocking the ducts.

Exhaust connection: The hood exhaust has been designed to mate with a standard 31⁄4” x 10” (8.2 x 25.4 cm) rectangular duct.If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6” (15.2 cm) diameter duct.

Maximum duct length: For satisfactory air movement, the total duct length of 31⁄4” x 10” (8.2 x 25.4 cm) rectangular or 6” (15.2 cm)diameter round duct should not exceed 120 equivalentfeet (36.5 m).

Elbows, transitions, wall and roof caps,etc., present additional resistance to airflow and areequivalent to a section of straight duct which is longerthan their actual physical size. When calculating the totalduct length, add the equivalent lengths of all transitionsand adaptors plus the length of all straight duct sections.The chart below shows you how to calculate totalequivalent ductwork length using the approximate feetof equivalent length of some typical ducts.

5

Installation Instructions

Page 6: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

PART QUANTITY

Top Cabinet 1Template

Rear Wall 1Template

Installation 1Instructions

Separately 2Packed Grease Filters

PART QUANTITY

Wood Screws 2(1⁄4“ x 2“)

Toggle Bolts (and 4 wing nuts) (3⁄16“ x 3“)

Self-Aligning Machine 3 Screws (1⁄4“-28 x 31⁄4“)

Nylon Grommet 2(for metal cabinets)

Power Cord Strap 1(plastic)

6

• If the unit is damaged in shipment, return theunit to the store in which it was bought for repairor replacement.

• If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.

• If the unit is damaged by the installer (if otherthan the customer), repair or replacement mustbe made by arrangement between customer and installer.

DAMAGE—SHIPMENT/INSTALLATION

PARTS INCLUDED (CONT.)

INSTALLATIONINSTRUCTIONS

ADDITIONAL PARTS

TOP CABINET TEMPLATE

Installation Instructions

REARWALL

TEMPLATE

PARTS INCLUDED

You will find the installation hardware contained ina packet with the unit. Check to make sure you haveall these parts.NOTE: Some extra parts are included.

HARDWARE PACKET

Page 7: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

7

TOOLS YOU WILL NEED

# 1 Phillips screwdriver Pencil

Ruler or tape measure andstraight edge

Carpenter square(optional)

Tin snips (for cuttingdamper, if required)

Electric drill with 3⁄16“, 1⁄2“ and 5⁄8“drill bits

Hammer (optional)Stud finder or

Filler blocks or scrapwood pieces, if needed for top cabinet spacing(used on recessed bottomcabinet installations only)

Gloves

Saw (saber, hole or keyhole)

LevelDuct and masking tape

MOUNTING SPACE

NOTES:• The space between the cabinets must be

30“ (76.2 cm)wide and free of obstructions. • If you are going to vent your microwave oven

to the outside, see Hood Exhaust Section forexhaust duct preparation.

• When installing the microwave oven beneathsmooth, flat cabinets, be careful to follow theinstructions on the top cabinet template for power cord clearance.

Backsplash

66″ (167.6 cm)or More fromthe Floor to theTop of theMicrowave

30“ (76.2 cm)

2“ (5.1 cm)

30“(76.2 cm)

min.

161⁄2“ (41.9 cm)

Bottom Edge ofCabinet Needs tobe 30″ (76.2 cm)

or More from theCooking Surface

Installation Instructions

Scissors (to cut template, if necessary)

Safety goggles

Page 8: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

8

Find the studs, using one of the following methods:A. Stud finder – a magnetic device which

locates nails.OR

B. Use a hammer to tap lightly across the mounting surface to find a solid sound. This will indicate a stud location.

After locating the stud(s), find the center by probing the wall with a small nail to find the edgesof the stud. Then place a mark halfway betweenthe edges. The center of any adjacent studs shouldbe 16″ (40.6 cm) or 24″ (61 cm) from this mark.Draw a line down the center of the studs.

THE MICROWAVE MUST BE CONNECTED TO AT LEAST ONE WALL STUD.

1

Remove the installation instructions, filters, glasstray and the small hardware bag. Do not removethe Styrofoam protecting the front of the oven.

Fold back all 4 carton flaps fully against cartonsides. Then carefully roll the oven and carton overonto the top side. The oven should be resting inthe Styrofoam.

REMOVING THE MICROWAVEOVEN FROM THE CARTON/REMOVING THE MOUNTING PLATE

FINDING THE WALL STUDSB.A.

2

PLACEMENT OF THE MOUNTING PLATE1

Wall Studs

Center

3

Carton

Pull the carton up and off the oven.

Remove the screws from the mounting plate. This plate will be used as the rear wall templateand for mounting. Reinstall the screws into theholes where they were removed.

MountingPlateScrews

2

Styrofoam

Installation Instructions

3

5

Remove and properly discard plastic bags.4

1

Page 9: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

9

DETERMINING WALL PLATE LOCATION UNDER YOUR CABINETC.

Your cabinets may have decorative trim that interferes with the microwave installation. Remove the decorative trim to install the microwave properlyand to make it level.

THE MICROWAVE MUST BE LEVEL.Use a level to make sure the cabinet bottom is level.

If the cabinets have a front overhang only, with no back or side frame, install the mounting plate down the same distance as the front overhang depth. This will keep the microwave level.

Measure the inside depth of the front overhang.

Draw a horizontal line on the back wall an equal distance below the cabinet bottom as the insidedepth of the front overhang.For this type of installation with front overhang only,align the mounting tabs with this horizontal line, nottouching the cabinet bottom as described in Step D.

Plate position—beneath flat bottom cabinet

Plate position—beneath recessed bottomcabinet with front overhang

Mounting Plate Tabs Touching the Cabinet Bottom

At least 30″ (76.2 cm),up to 36″ (91.4 cm)

Plate position—beneath framed recessed cabinet bottom

Installation Instructions

1

2

3

30″ (76.2 cm)to Cooktop

Mounting Plate Tabs Touching the Back Frame

Mounting Plate withTabs Below CabinetBottom the SameDistance as the FrontOverhang Depth

30″ (76.2 cm)to Cooktop

Page 10: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

10

ALIGNING THE WALL PLATE

Draw a vertical line on the wall at the center of the 30″ (76.2 cm) wide space.Use the mounting plate as the template for the rearwall. Place the mounting plate on the wall, making sure that the tabs are touching the bottom of the cabinet or the level line drawn in Step C for cabinetswith front overhang. Line up the notch and centerlineon the bottom of the mounting plate to the centerlineon the wall.While holding the mounting plate with one hand, draw circles on the wall at holes A, B, C and D (see illustration above/actual plate marked witharrows). Four holes must be used for mounting.

NOTE: If neither C nor D is in a stud, find a studsomewhere in area E and draw a fifth circle to line upwith the stud. It is important to use at least one woodscrew mounted firmly in a stud to support the weightof the microwave.Set the mounting plate aside.Drill holes on the circles. If there is a stud, drill a 3⁄16″hole for wood screws. For holes that don’t line up witha stud, drill a 5⁄8″ hole for toggle bolts.NOTE: DO NOT MOUNT THE PLATE AT THIS TIME.

1

2

3

4

D.

Installation Instructions

CAUTION: Wear glovesto avoid cutting fingers onsharp edges.

Draw a VerticalLine on Wallfrom Center ofTop Cabinet

Area E

Hole A Hole B

Hole DHole C

CenterlineNotches

Page 11: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

A

INSTALLATION TYPES (Choose A, B or C)

This microwave oven is designed for adaptation to the following three types of ventilation: A. Outside Top Exhaust (Vertical Duct)B. Outside Back Exhaust (Horizontal Duct)C.Recirculating (Non-Vented Ductless)

NOTE: This microwave is shipped assembled for OutsideTop Exhaust (except for non-vented models). Select thetype of ventilation required for your installation and proceed to that section.

OUTSIDE TOP EXHAUST(VERTICAL DUCT)

OUTSIDE BACK EXHAUST(HORIZONTAL DUCT)

RECIRCULATING(NON-VENTED DUCTLESS)

See page 12 See page 15

See page 19

On models shipped for recirculating exhaust, adisposable charcoal filter is factory installed to helpremove smoke and odors.

On Models shipped foroutside top exhaust or outsideback exhaust, a Charcoal filterAccessory Kit is required forthe recirculating exhaust. (See your Owner's Manual for kit number.)

Adaptor in Place forOutside Top Exhaust

Installation Instructions

2

B

C

11

Adaptor Must BeMoved to the Back forOutside Back Exhaust

Page 12: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

Place the mounting plate against the wall andinsert the toggle wings into the holes in the wall to mount the plate.

NOTE: Before tightening toggle bolts and woodscrew, make sure the tabs on the mounting platetouch the bottom of the cabinet when pushed flush against the wall and that the plate is properlycentered under the cabinet.CAUTION: Be careful to avoid pinching fingersbetween the back of the mounting plate and the wall.

Tighten all bolts. Pull the plate away from the wallto help tighten the bolts.

3

4

ATTACH THE MOUNTINGPLATE TO THE WALL

A1.

12

Attach the plate to the wall using toggle bolts. At least one wood screw must be used to attach the plate to a wall stud.

Remove the toggle wings from the bolts.

Insert the bolts into the mounting plate through the holes designated to go into drywalland reattach the toggle wings to 3⁄4″ (19 mm) ontoeach bolt.

1

INSTALLATION OVERVIEWA1. Attach Mounting Plate to WallA2. Prepare Top CabinetA3. Check Damper OperationA4. Mount Microwave OvenA5. Adjust Exhaust AdaptorA6. Connect Ductwork

Wall

MountingPlate

Spacing for TogglesMore Than WallThickness

Bolt End

Toggle Bolt

Toggle Wings

To use toggle bolts:

Installation Instructions

2

OUTSIDE TOP EXHAUST (Vertical Duct)A

Page 13: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

13

3

MOUNT THE MICROWAVEOVEN

A4.

CHECK FOR PROPERDAMPER OPERATION

A3.

USE TOP CABINET TEMPLATEFOR PREPARATION OF TOPCABINET

You need to drill holes for the top support screws, ahole large enough for the power cord to fit through,and a cutout large enough for the exhaust adaptor.

A2.

FOR EASIER INSTALLATION AND PERSONALSAFETY, WE RECOMMEND THAT TWO PEOPLEINSTALL THIS MICROWAVE OVEN. IMPORTANT: Do not grip or use handleduring installation.NOTE: If your cabinet is metal, use the nylon grommet around the power cord hole to prevent cutting of the cord.NOTE: We recommend using filler blocks if the cabinet front hangs below the cabinet bottom shelf.

IMPORTANT: If filler blocks are not used, case damage may occur from overtightening screws.

Insert a self-aligning screw through top center cabinet hole. Temporarily secure the oven by turning the screw at least two full turns after thethreads have engaged. (It will be completelytightened later.) Be sure to keep power cordtight. Be careful not to pinch the cord, especiallywhen mounting flush to bottom of cabinet.

Exhaust AdaptorBlower Plate

Damper

Back ofMicrowave

• Read the instructions on the TOP CABINET TEMPLATE.

• Tape it underneath the top cabinet.• Drill the holes, following the instructions on the

TOP CABINET TEMPLATE.

CAUTION: Wear safety goggles when drilling holesin the cabinet bottom.

Installation Instructions

• Place the microwave in its upright position, with thetop of the unit facing up.

• Make sure tape securing damper is removed anddamper pivots easily before mounting microwave.

• You will need to make adjustments to assure properalignment with your house exhaust duct after themicrowave is installed.

2 Rotate front of ovenup against cabinet bottom.

NOTE: When mounting themicrowave oven, threadpower cord through hole inbottom of top cabinet. Keepit tight throughout Steps1–3. Do not pinch cord orlift oven by pulling cord.

Lift microwave, tilt itforward, and hookslots at back bottomedge onto four lowertabs of mountingplate.

1

Page 14: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

14

4 Attach the microwave oven to the top cabinet.

8

7

6

Cabinet Front

Cabinet Bottom Shelf

Tighten the outer two screws to the top of themicrowave oven. (While tightening screws, holdthe microwave oven in place against the wall andthe top cabinet.)

Filler Block

Microwave Oven Top

Equivalent to Depth of CabinetRecess

Insert 2 self-aligning screwsthrough outer top cabinetholes. Turn two full turns oneach screw.

Tighten center screw completely.

Install grease filters. See the Owner’s Manualpacked with the microwave.

Installation Instructions

ADJUST THE EXHAUSTADAPTOR

A5.

Open the top cabinet and adjust the exhaust adaptorto connect to the house duct.

Back of Microwave

For Front-to-Back or Side-to-Side Adjustment,Slide the Exhaust Adaptoras Needed

Blower Plate Damper

CONNECTING DUCTWORK

1

2

Extend the house duct down to connect tothe exhaust adaptor. Seal exhaust duct joints using duct tape.

A6.

House Duct

Self-Aligning Screw

5

MOUNT THE MICROWAVEOVEN (cont.)

A4.

Page 15: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

This microwave oven is shipped assembled for topexhaust. You will need the exhaust adaptor forinstallation in the rear wall opening. To remove the exhaust adaptor from the microwave oven:

Remove tape securing damper.

2 Slip the damperout of the track on the blowerframe by pressingand twistingboth ends.

INSTALLATION OVERVIEWB1. Prepare Rear WallB2. Remove Exhaust AdaptorB3. Attach Mounting Plate to WallB4. Prepare Top CabinetB5. Adjust BlowerB6. Mount the Microwave Oven

IMPORTANT NOTES:• Make sure the screws for the

blower motor and blower plate are securely tightened when they are reinstalled. This will help to prevent excessive vibration.

• Make sure the motor wiring has been properly routed and secured, and that the wires are not pinched.

Remove and save the screw that holds the blowerplate to the microwave. Lift off the blower plate.

Back of Microwave

Back of Microwave

Raise damper flap.

Installation Instructions

15

3

4

1

PREPARING THE REAR WALL FOR OUTSIDE BACK EXHAUST

B1.

You need to cut an opening in the rear wall foroutside exhaust.

• Read the instructions on the REAR WALL TEMPLATE.

• Tape it to the rear wall, lining up with the holes previously drilled for holes A and B in the wall plate.

• Cut the opening, following the instructions of theREAR WALL TEMPLATE.

REMOVE EXHAUST ADAPTOR B2.

OUTSIDE BACK EXHAUST (Horizontal Duct)B

Blower Plate

Blower Plate

Page 16: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

ATTACH THE MOUNTINGPLATE TO THE WALL

B3.

16

USE TOP CABINET TEMPLATEFOR PREPARATION OF TOP CABINET

B4.

• Read the instructions on the TOP CABINETTEMPLATE.

• Tape it underneath the top cabinet.• Drill the holes, following the instructions on the

TOP CABINET TEMPLATE.

CAUTION: Wear safety goggles when drilling holes in the cabinet bottom.

Wall

MountingPlate

Spacing for Toggles MoreThan Wall Thickness

Toggle Bolt

Toggle Wings

To use toggle bolts:

Bolt End

Installation Instructions

You need to drill holes for the top support screws anda hole large enough for the power cord to fit through.

Attach the plate to the wall using toggle bolts. At least one wood screw must be used to attach the plate to a wall stud.

Remove the toggle wings from the bolts.

Insert the bolts into the mounting plate throughthe holes designated to go into drywall and reattachthe toggle wings to 3⁄4″ (19 mm) onto each bolt.

1

2

Place the mounting plate against the wall andinsert the toggle wings into the holes in the wall to mount the plate.

NOTE: Before tightening toggle bolts and woodscrew, make sure the tabs on the mounting platetouch the bottom of the cabinet when pushed flushagainst the wall and that the plate is properlycentered under the cabinet.CAUTION: Be careful to avoid pinching fingersbetween the back of the mounting plate and the wall.

Tighten all bolts. Pull the plate away from the wallto help tighten the bolts.

3

4 BEFORE: Fan BladeOpenings Facing Up

2

1 Remove and save screw that holds blower motorto microwave.

ADAPTING MICROWAVEBLOWER FOR OUTSIDEBACK EXHAUST

B5.

End B

End A

Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit.

Back ofMicrowave

Blower Motor

Blower MotorScrew

Page 17: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

Attach the exhaust adaptor to the rear of theoven by sliding it into the guides at the topcenter of the back of the oven.

AFTER: Fan BladeOpenings Facing Back

6 Place the blower unit back into the opening.

8 Replace the blower plate in the same positionas before with the screw. Make sure the screw is tight.

7

Roll the blower unit 90° so that fan bladeopenings are facing out the back of themicrowave.

5

4

3

ADAPTING MICROWAVEBLOWER FOR OUTSIDEBACK EXHAUST (cont.)

B5.

17

Rotate blower unit counterclockwise 180°.

Before Rotation After Rotation

Gently remove the wires from the grooves.Reroute the wires through grooves on other sideof the blower unit.

Before Rerouting After Rerouting

Wires Routed Through Right Side Wires Routed Through Left Side

Back ofMicrowave

Back ofMicrowave

Blower Plate

Blower MotorScrew

Secure the blower unit to the microwave withthe original screw.

Before Rolling After Rolling

Back ofMicrowave

End A

End B

Back ofMicrowave

Back ofMicrowave

9

CAUTION: Do not pull or stretch the blowerunit wiring. Make sure the wires are notpinched, and that they are properly secured.

NOTE: The blower unit exhaustopenings should match exhaustopenings on rear of microwave oven.

Installation Instructions

Push in securely until it is in the lower lockingtabs. Take care to assure that the damper hingeis installed so that it is at the top and that thedamper swings freely.

Guide

Guide

Adaptor

Locking Tabs

Back of Microwave

Page 18: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

Attach the microwave oven to the top cabinet.

18

Installation Instructions

3

MOUNT THE MICROWAVEOVEN

B6.

FOR EASIER INSTALLATION AND PERSONALSAFETY, WE RECOMMEND THAT TWO PEOPLEINSTALL THIS MICROWAVE OVEN.

IMPORTANT: Do not grip or use handleduring installation.NOTE: If your cabinet is metal, use the nylongrommet around the power cord hole to preventcutting of the cord.NOTE: We recommend using filler blocks if the cabinet front hangs below the cabinet bottom shelf.

IMPORTANT: If filler blocks are not used, case damage may occur fromovertightening screws.

Insert a self-aligning screw through top center cabinet hole. Temporarily secure the oven by turning the screw at least two full turns after thethreads have engaged. (It will be completelytightened later.) Be sure to keep power cordtight. Be careful not to pinch the cord, especiallywhen mounting flush to bottom of cabinet.

8

7

5

Cabinet Front

Cabinet Bottom Shelf

Tighten the outer two screws to the top of themicrowave oven. (While tightening screws, holdthe microwave oven in place against the wall andthe top cabinet.)

Filler Block

Microwave Oven Top

Equivalent to Depth of CabinetRecess

Insert 2 self-aligning screwsthrough outer top cabinetholes. Turn two full turns oneach screw.

Tighten center screw completely.

Install grease filters. See the Owner’s Manualpacked with the microwave.

Self-Aligning Screw

6

4

2 Rotate front of ovenup against cabinet bottom.

NOTE: When mounting themicrowave oven, threadpower cord through hole inbottom of top cabinet. Keepit tight throughout Steps1–3. Do not pinch cord orlift oven by pulling cord.

Lift microwave, tilt itforward, and hookslots at back bottomedge onto four lowertabs of mountingplate.

1

Page 19: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

USE TOP CABINET TEMPLATEFOR PREPARATION OF TOP CABINET

C2.

19

INSTALLATION OVERVIEWC1. Attach Mounting Plate to WallC2. Prepare Top Cabinet C3. Check Microwave AssemblyC4. Adjust BlowerC5. Mount the Microwave OvenC6. Install Charcoal Filter

IMPORTANT NOTES:• Make sure the screws for the blower motor and blower

plate are securely tightened when they are reinstalled.This will help to prevent excessive vibration.

• Make sure the motor wiring has been properly routedand secured, and that the wires are not pinched.

• Read the instructions on the TOP CABINETTEMPLATE.

• Tape it underneath the top cabinet.• Drill the holes, following the instructions on the

TOP CABINET TEMPLATE.CAUTION: Wear safety goggles when drilling holesin the cabinet bottom.

Installation Instructions

You need to drill holes for the top support screws anda hole large enough for the power cord to fit through.

Place the mounting plate against the wall andinsert the toggle wings into the holes in the wall to mount the plate.

NOTE: Before tightening toggle bolts and woodscrew, make sure the tabs on the mounting platetouch the bottom of the cabinet when pushed flushagainst the wall and that the plate is properlycentered under the cabinet.CAUTION: Be careful to avoid pinching fingersbetween the back of the mounting plate and the wall.

Tighten all bolts. Pull the plate away from the wallto help tighten the bolts.

4

3ATTACH THE MOUNTINGPLATE TO THE WALL

C1.

Attach the plate to the wall using toggle bolts. At least one wood screw must be used to attach the plate to a wall stud.

Remove the toggle wings from the bolts.

Insert the bolts into the mounting plate throughthe holes designated to go into drywall andreattach the toggle wings to 3⁄4″ (19 mm) ontoeach bolt.

1

Wall

MountingPlate

Spacing for TogglesMore Than WallThickness

Bolt End

Toggle Bolt

Toggle Wings

To use toggle bolts:

2

RECIRCULATING (Non-Vented Ductless)C

Page 20: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

AFTER: Fan BladeOpenings Facing Forward

5

4

3

6

ADAPTING MICROWAVEBLOWER FOR RECIRCULATION

C4.

20

Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit.

Roll the blower unit 90° so that fan blade openingsare facing toward the front of the microwave.

Roll

Slip the damperout of the trackon the blowerframe by pressingand twistingboth ends.

Remove the screw that holds the blower plate to the microwave. Remove and save the screwholding the blower motor to the microwave.

Blower Plate

Blower MotorScrew

Back ofMicrowave

Remove tape securing damper.

Raise damper flap.

NOTE: Make sure wires remain routed in thegrooves of the motor frame.

Installation Instructions

BEFORE: Fan BladeOpenings Facing Up

Back of Microwave

CHECK MICROWAVE ASSEMBLYC3.

Exhaust Adaptor

Back ofMicrowave

• Place the microwave in its upright position, with thetop of the unit facing up.

• The microwave oven may be shipped assembled fortop exhaust (adaptor installed) or for recirculationexhaust (adaptor absent).

• If the microwave was shipped for recirculationexhaust, remove the Exhaust Adaptor and proceedto C5. If the microwave was shipped for top exhaust,proceed to C4.

1

2

NOTE: The blower plate will be reinstalled in a later step. The damper is not needed for recirculatingmodels. Save any unused parts for possible future use.

Blower Plate

Page 21: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

9

8

7

ADAPTING MICROWAVEBLOWER FOR RECIRCULATION (cont.)

C4.

21

Place the blower unit back into the opening. CAUTION: Do not pull or stretch the blower unitwiring. Make sure the wires are not pinched, andthat they are properly secured.

Replace blower plate with the screw removed inStep 1. Make sure the screw is tight.

Secure blower unit to microwave with the screwremoved in Step 4. Make sure the screw is tight.

Attach the microwave oven to the top cabinet.

Cabinet Front

Cabinet Bottom Shelf

Filler Block

Microwave Oven Top

Equivalent to Depthof Cabinet Recess

Back ofMicrowave

Installation Instructions

3

MOUNT THE MICROWAVEOVEN

C5.

FOR EASIER INSTALLATION AND PERSONALSAFETY, WE RECOMMEND THAT TWO PEOPLEINSTALL THIS MICROWAVE OVEN.

IMPORTANT: Do not grip or use handleduring installation.NOTE: If your cabinet is metal, use the nylongrommet around the power cord hole to preventcutting of the cord.NOTE: We recommend using filler blocks if the cabinet front hangs below the cabinet bottom shelf.

IMPORTANT: If filler blocks are not used,case damage may occur from overtighteningscrews.

Insert a self-aligning screw through top center cabinet hole. Temporarily secure the oven by turning the screw at least two full turns after thethreads have engaged. (It will be completelytightened later.) Be sure to keep power cordtight. Be careful not to pinch the cord, especiallywhen mounting flush to bottom of cabinet.

Self-Aligning Screw

4

2 Rotate front of ovenup against cabinet bottom.

NOTE: When mounting themicrowave oven, threadpower cord through hole inbottom of top cabinet. Keepit tight throughout Steps1–3. Do not pinch cord orlift oven by pulling cord.

Lift microwave, tilt it forward, and hookslots at back bottomedge onto four lowertabs of mountingplate.

1

Page 22: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

5

6

3

4

2

1

INSTALLING THE CHARCOAL FILTER

C6.MOUNT THE MICROWAVEOVEN (cont.)

C5.

Install the charcoal filter. When properly installed,the wire mesh of the filter should be visible fromthe front.Replace the grille and the screws.

Close the door.

22

CharcoalFilter

Insert mesh-side up

Remove screws on front of grille using a #1 Phillips screwdriver.

Open the door.

Remove the grille.

Pull the grille straight off.

Installation Instructions

8

7

6

Tighten the outer two screws to the top of themicrowave oven. (While tightening screws, holdthe microwave oven in place against the wall andthe top cabinet.)

Insert 2 self-aligning screwsthrough outer top cabinetholes. Turn two full turns oneach screw.

Tighten center screw completely.

Install grease filters. See the Owner’s Manualpacked with the microwave.

5

NOTE: The charcoal filter is factory installed inrecirculating models. Follow these steps to replace afilter or to install a filter after converting a ventedmodel to recirculating operation.

Page 23: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

KEEP INSTALLATION INSTRUCTIONSFOR THE LOCAL INSPECTOR’SUSE.

Plug power cord into a dedicated 15- to 20-ampelectrical outlet.

7.

Read the Owner’s Manual.6.

Replace house fuse or turn breaker back on. 4.

Remove all packing material from the microwave oven.

2.

Make sure the microwave oven has beeninstalled according to instructions.1.

23

BEFORE YOU USE YOUR MICROWAVE

Ensure properground existsbefore use

INSTALLATION

INSTRUCTIONS

INSTALLATION

INSTRUCTIONS

OWNER’S

MANUAL

Installation Instructions

Install turntable and ring in cavity.3.

5.

Page 24: 7 Installation Over the Range Instructions Microwave Oven · or Visit our Website at: READ CAREFULLY. KEEP THESE INSTRUCTIONS. Installation Over the Range Instructions Microwave Oven

Printed in China