64283 darmstadt component-id 0605wi03 valid until 31st ... · the passive house institute has...
TRANSCRIPT
CERTIFICATECertified Passive House Component
Passive House InstituteDr. Wolfgang Feist64283 Darmstadt
GermanyComponent-ID 0605wi03 valid until 31st December 2020
www.passivehouse.com
Category: Window FrameManufacturer: Aluprof S.A.,
Bielsko-Biała,Poland
Product name: MB-104 Passive SI
This certificate was awarded based on the followingcriteria for the cool, temperate climate zone
Comfort UW = 0.80 ≤ 0.80 W/(m2 K)UW ,installed ≤ 0.85 W/(m2 K)with Ug = 0.70 W/(m2 K)
Hygiene fRsi=0.25 ≥ 0.70
CERTIFIEDCOMPONENTPassive House Institute
cool, temperate climate
phCPassive House
efficiency class phE phD phC phB phA
Aluprof S.A.Warszawska 153, 43-300 Bielsko-Biała, PolandT +48 33 8195300 |B [email protected] | Í http://www.aluprof.eu/ |
20 o
C
18 o
C
16 o
C
14 o
C
12 o
C
10 o
C
8 o
C
6 o
C
4 o
C
2 o
C
0 o
C
-2 o
C
-4 o
C
-6 o
C
-8 o
C
-10 o
C
Calculation model Isothermal
Description
Aluminium frame with insulationcore made of expanded polystyrene and rebate insulation of poly-ethylene foam. Pane thickness: 48 mm (4/18/4/18/4), Rebate depth: 15 mm.
Explanation
The window U-values were calculated for the test window size of 1.23 m× 1.48 m with Ug = 0.70 W/(m2 K).If a higher quality glazing is used, the window U-values will improve as follows:
Glazing Ug = 0.70 0.64 0.58 0.54 W/(m2 K)↓ ↓ ↓ ↓
Window UW = 0.80 0.76 0.73 0.70 W/(m2 K)
Transparent building components are classified into efficiency classes depending on the heat lossesthrough the opaque part. The frame U-Values, frame widths, thermal bridges at the glazing edge, andthe glazing edge lengths are included in these heat losses. A more detailed report of the calculationsperformed in the context of certification is available from the manufacturer.
The Passive House Institute has defined international component criteria for seven climate zones. Inprinciple, components which have been certified for climate zones with higher requirements may alsobe used in climates with less stringent requirements. In a particular climate zone it may make senseto use a component of a higher thermal quality which has been certified for a climate zone with morestringent requirements.
Further information relating to certificationcan be found on www.passivehouse.com and passipedia.org.
2/4 MB-104 Passive SI
www.passivehouse.com
Frame width U-value frame Ψ -panel edge Temp. Factorbf Uf Ψg fRsi=0.25
Framevalues mm W/(m2 K) W/(m K) [-]
Top (to) 150 0.83 0.021 0.77
Side (s) 150 0.83 0.021 0.77
Bottom (bo) 150 0.83 0.021 0.77
Mullionflying
(fm) 182 0.77 0.020 0.77
Spacer: SWISSPACER Ultimate Secondary seal: Polysulfid
Validated installations
EIFS
Ψinstall W/(m K)Top 0.011Side 0.011Bottom 0.029
UW ,installed = 0.85 W/(m2 K)
Insulated formwork blocks
Ψinstall W/(m K)Top 0.010Side 0.010Bottom 0.022
UW ,installed = 0.84 W/(m2 K)
Timber frame
Ψinstall W/(m K)Top 0.015Side 0.015Bottom 0.029
UW ,installed = 0.85 W/(m2 K)
3/4Component-ID: 0605wi03
www.passivehouse.com
www.passivehouse.com