6241-a-111 161 type a - fronting ido - ground floor plan
DESCRIPTION
Fronting IDO - Ground Floor PlanTRANSCRIPT
-
2324
2125
3008890300
3660100
184575
3210
3660100
5129300
1115
Blockwork wallbuilt off slab
FD30 838
838
FD30
838
686
1
2
3
4
5
6
300
300
5770
8478
9701350158616601350970
300
7878
300
3043
7510
25
Wallmountedelec. meter
position
685
4315
3478
300
9490
Kitchen
Lounge
WC
Hall
St.
rwp
rwp
SVP
A-ASect
1004
1500
Boiler flueoutlet
Cooker hoodextract route
210l water butt with base, lid,tap and overflow connected
to downpipe as per MJAConsulting
Ground Floor Plan
1163
Refer to StandardTaylor Wimpley
Stair Drawing
838
FD30 838
838
7
8
9
120016721500134027
2975
5073
100
3635
2930 75
420
1080 4050
100
4142
3217
793 2461
1025
Dining
WashingMachineop. extra
FridgeFreezerop. extra
Dish Washerop. extraBreakfast
BlrSVP
FamilyRoom
Level Threshold
WallmountedGas. meter
position
Entrance CanopyPosts supportingcanopy
225 1782 225
225
533
1010 1008
910
1198
1st Floor Joists
1st Floor Joists
1st F
loor
Joi
sts
1st F
loor
Joi
sts
Trim
mer
HD/K-100
HD/K-100 HD/K-100HD/K-100
S/K
-100
HD/K-100
BOX/K-100
HD/K-100
Trimmer
Entrance CanopyStructural items bySupplier
BOX/K-100
1116
100
25
3040
54
138
175
SVP & Shower Vertto Plot 151 Only
Level Threshold
PLOTS
-67 (As Shown) - Fronting IDO-69 (As Shown) - Fronting IDO-74 (As Shown) - Fronting IDO-151 (Opposite) - Fronting IDO
REFER TO STANDARD DETAILS 28/40h-49h FOR DETAIL OFRAMP/LEVEL STANDING TO FRONT DOOR
Wall mounted gasmeter position
Wall mounted elec.meter position
30 Minutes Fire Resisting ConstructionAny doors/access panels in/out of theseenclosures to be FD30 panels/doors.All partitions to the perimeter of theprotected lobby to be built upto undersideof floor.
Semi concealedgas meter position
Note:Party Walls between dwellings to comply with Robust StandardDetail RSD E-WM-11
Water meter position
This drawing is the copyright of Roberts Limbrick Ltdand should not be reproduced in whole or inpart or used in any manner whatsoever withouttheir written permission.Do Not scale off this drawing, use only figureddimensions and report any discrepancies oromissions to the Architect immediately.
project
client
drawing
scale
date author
rev. date description
drg no. rev.
status
1/50 @ A3
20/10/09 PS
Amended to as per TW commentsand Issued for ConstructionPending Suppliers Approval
MAR'10A
WC Door amended to swingoutwards
JUN'10B
Dims to internal doors addedAug'10CFront door size changed to 1004mmJan'11DPlots 76, 88, & 146 removed, Plots74, 67, & 69 added
Feb'11E
Plot 151 AddedJul'11FPlot 151 Shower Vert AddedAug'11GPlot 67 Handing changed to asShown
Sept'11H
Blockwork wall to side of storeamended, and level thershold to therear.
Oct'12I
-
12
3
4
5
6
Kitchen
Lounge
WC
Hall
St.
rwp
rwp
SVP
Telephoneentry point
t
LE
LE
LE
5073
mm
[16'
-8"F
T]
3610mm [11'-10"FT]
5105mm
[16'-9"FT]
3585
mm
[11'
-9"F
T]
3206mm
[10'-6"FT]
3043
mm
[10'
-0"F
T]
7
8
9
3610mm
[11'-10"FT]
2704
mm
[8'-1
0"FT
]
LE
Dining
S
TAP
AP
G
Breakfast
BlrT
SVP
FamilyRoom
SVP & Shower Vertto Plot 151 Only
C
ELECTRICAL:
IP rating for light fitting to bathrooms to be suitable for zone inwhich it is to be positioned
IMMERSION HEATER
EXTRACT FAN ISOLATING SWITCH (2000mm above FFL)
EXTRACT / WHOLE HOUSE VENTILATION GRILLE / FAN
BATTEN HOLDER LIGHT FITTING
SERVICES LEGEND
UNSWITCHED SOCKET OUTLET (high level) single/double
SWITCHED SOCKET OUTLET (w/t level) single/doubleSWITCHED SOCKET OUTLET (high level) single/double
SWITCHED SOCKET OUTLET (low level) single/double
1 GANG 3 MODULE SWITCH PLATE (LIGHT/FAN/FUSE)
UNSWITCHED SOCKET OUTLET (w/t level) single/doubleUNSWITCHED SOCKET OUTLET (low level) single/double
SWITCHED FUSED SPUR (low level)
SWITCHED FUSED SPUR (w/t level)
SWITCHED FUSED SPUR (high level)
LIGHT SWITCH
FLUORESCENT STRIP LIGHT
SHAVER UNIT
2 WAY LIGHT SWITCH
FUSED SPUR (w/t level)
FUSED SPUR (high level)
FUSED SPUR (low level)
PENDANT LIGHT FITTING
LOW VOLTAGE INTERNAL WALL LIGHT
NEON INDICATOR LIGHT SWITCH
SWITCHED FUSED SPUR WITH NEON INDICATOR
SPOT LIGHTS ON TRACK (Number of lights shown)
ENERGY EFFICIENT LIGHTING4-PIN CFL PENDANT FITTING
PIR OUTDOOR SECURITY LIGHT(automatic night time only)
LOW VOLTAGE RECESSED DOWNLIGHT(refer to THD National Construction Specification forTrad build houses in England and Wales Clause 26.3)
COOKER CONTROL UNIT INCORPORATING ASWITCHED SOCKET OUTLET
COOKER TAIL PLATE OR UNSWITCHED SOCKETOUTLET - TO SUIT COOKER POWER RATING
45 amp COOKER CONTROL SWITCH WITH NOSOCKET OUTLET
SWITCHED FUSED SPUR WITH NEON INDICATORABOVE WORKTOP CONNECTED TO UNSWITCHEDSOCKET OUTLET BELOW
SWITCHED FUSED SPUR ABOVE WORKTOPCONNECTED TO UNSWITCHED SOCKET OUTLETBELOW
LE
3
N
N
T
NAP
TAP
EX
45amp
ENERGY EFFICIENT LIGHTINGBATTEN HOLDER FITTING
AP MULTIGANG SWITCHED FUSED SPUR ABOVEWORKTOP CONNECTED TO UNSWITCHED SOCKETOUTLETS TO APPLIANCES
(light switch level)
REFER TO STANDARD DETAILS 28/40h-49h FOR DETAIL OFRAMP/LEVEL STANDING TO FRONT DOOR
Wall mounted gasmeter position
Wall mounted elec.meter position
30 Minutes Fire Resisting ConstructionAny doors/access panels in/out of theseenclosures to be FD30 panels/doors.All partitions to the perimeter of theprotected lobby to be built upto undersideof floor.
Semi concealedgas meter position
Note:Party Walls between dwellings to comply with Robust StandardDetail RSD E-WM-11
Water meter position
PLOTS
-67 (As Shown) - Fronting IDO-69 (As Shown) - Fronting IDO-74 (As Shown) - Fronting IDO-151 (Opposite) - Fronting IDO
This drawing is the copyright of Roberts Limbrick Ltdand should not be reproduced in whole or inpart or used in any manner whatsoever withouttheir written permission.Do Not scale off this drawing, use only figureddimensions and report any discrepancies oromissions to the Architect immediately.
project
client
drawing
scale
date author
rev. date description
drg no. rev.
status
1/50 @ A3
20/10/09 AR
Amended to as per TW commentsand Issued for ConstructionPending Suppliers Approval
MAR'10A
WC Door amended to swingoutwards
JUN'10B
External PIR Light shown and13amp fused spur added for alarmin hall
Nov'10C
Plots 76, 88, & 146 removed, Plots74, 67, & 69 added
Feb'11D
Plot 151 addedFeb'11EPlot 151 Shower Vert AddedAug'11FPlot 67 Handing changed to asShown
Sept'11G
CO monitor & external lighting addedNov'12H