60 hz flygt n-pump series brochure
TRANSCRIPT
Flygt N-pump SeriesSelF-cleaNiNg pumpS with SuStaiNed high eFFicieNcy
2
the N-pump advaNtage
• Patentedtechnology• Innovativedesign• Sustainedhighefficiency• Self-cleaningability• Modulardesign• Reliable• Fewerunplannedservicecalls
Broad raNge capacity
• Ratingsfrom2.2hpto870hp• Dischargesupto20”(500mm)• Flowsupto16,000USGPM(1,000l/s)• Headsupto400ft(120m)• Submersibleanddryinstallations• EveryFlygtpumpisperformancetestedinthefactory
• Canhandledrysolidsupto8%
SustainedhighefficiencyispricelessFlygt N-pumps take on the toughest applications and get the job done. every component is designed and manufactured to deliver sustained high efficiency. thanks to the patented N-technology with its innovative self-cleaning impeller, Flygt N-pumps deliver the highest total efficiency — lowering your energy bill and reducing unplanned maintenance costs. that adds up to total peace of mind – and big savings over the long term.
Ourvastfluidhandlingknowledgeanddedicationtoresearchanddevelopmentleadtotechnologicaladvancesandcontinuousimprovement.
That’swhyourFlygtN-pumpsareatworkinmorethanahundredthousandinstallationsworldwide.Theyhaveproventobethebestandmostreliablechoiceforbothdryandsubmersibleinstallationsfarandawayoverourcompetition.
Robust and reliableEveryFlygtN-pumpistestedinthefactorytoensurehighperformanceandpremium
quality.Flygtproductsdeliveroutstanding,cost-effectiveperformancethathasbeenproveninapplicationssuchas:
•Wastewater•Stormwater•Sludge•Industrialeffluent•Rawwater•Coolingwater
3
Self-cleaningN-pumpsavesmoney
the SelF-cleaNiNg coNcept
Stage1.Mostsolidobjectsenteringthepumpwillpassthroughtheimpellerbetweentheimpellervanes.Ifanobjectgetscaughtontheleadingedgeofoneofthevanes,itwillslidealongthebacksweptshapetowardstheperimeteroftheinlet.
Stage2.Thesolidobjectwillslidealongthetipoftheimpellervaneinsidethereliefgroove.Theguidepinintheinsertringwillpushalltypesofsolidsawayfromthecenteroftheimpeller,alongtheleadingedgeandoutthroughthereliefgroove.
Sustained high efficiencyWhensolidobjectssuchasstringyfibrousmaterialandmoderntrashentertheinletofaconventionalpump,theytendtogetcaughtontheleadingedgesoftheimpellervanes.Thisbuildupreducestheimpeller’sefficiency,resultinginincreasedpowerconsumption(Fig.A)andgeneratingincreasedenergycharges.
Assolidscontinuetobuildupinsidetheimpeller,motorthermalprotectioncantripcausingthepumptostopandleadingtocostlyunplannedservicecalls.Ifaconventionalwastewaterpumprunsintermittently,thesolidsbuildupwillberemovedbybackflushingwhenthepumpisshutoffattheendoftheoperatingcycle.Whenthenextcyclebegins,efficiencyreturnstoitsinitialvaluesincetheimpellerisfreefromsolidobjects(FigB).
ThehighefficiencyoftheFlygtN-pumpissustainedovertimeduetoitsself-cleaningability,keepingenergycoststoaminimum(Fig.C).
AllFlygtN-pumpshavethesameself-cleaningperformanceregardlessofdutypoint.
A.Conventionalwastewaterpump
B.Conventionalpumprunningintermittently
C.FlygtN-pump
Energyconsumption Hydraulicefficiency Sustainedhighefficiency
[time] [time] [time]
Impeller
Reliefgrove
Pumphousing
Insertring
Guidepin
DESIGN
4
Broadcapacityrangetosuityourapplication
hard-iroN™ (60 hrc) For the tougheSt waStewater challeNgeS
AcceleratedweartestsprovethatHard-Iron™hydrauliccomponentskeeponworkingefficientlywithminimalwearafterpumpingwaterwithaveryhighconcentrationofcoarsesand(2,400tons).
FlygtN-pumpswithHard-Iron™componentscontinuetodeliversustainedhighefficiencywithoutcloggingorerosioncorrosion,prolonginglifetimeby200percentcomparedtostandardhardenedcastironhydraulics.
Flexible and modular designFlygtN-technologyenablesyoutotailorthehydraulicstomeettherequirementsofvirtuallyanyapplication.Choosethehardenedcastironversionfortypicalwastewaterapplicationsandthechopperringversionforcuttinglongfibersorsolids.TheHard-Iron™versionshouldbeusedinabrasiveapplicationsandwatersthatcouldcauseerosioncorrosionduetohighoxygencontent.
Whateveryouchoose,youneversacrificepumpefficiency–andyoucaneasilyswitchthemoduleiftheoperatingconditionschange.
Top performance with a broad capacity range
Castironimpellerwithhardenededgesandinsertringfortypicalpumpingapplications.
Extradurableoptionforabrasiveanderosioncorrosionapplications.
Chopperringforcuttinglongfibersorsolids.
Castiron Hard-Iron™(60HRC)
Hard-Iron™, hardened 60 HRCSteel, hardened 64 HRC
Ni-Hard 55 HRCSteel, hardened 53 HRCSteel, hardened 44 HRC
Hard-Iron, annealed 37 HRCCast iron, hardened 47 HRC
Steel, hardened 38 HRCStainless steel AISI 316, 215 HB (17 HRC)Stainless steel AISI 329, 249 HB (23 HRC)
Ni-resist 160 HB (7 HRC)Cast iron, peritic 196 HB (13 HRC)
.0
.1
.2
.3
.4
.5
.6
.7
.8
.9
.10
Compositecurvesforcomparisonpurposesonly.Consultengineeringdataforexactflowandheadcapabilities.
Largecapacitypumps Mediumcapacitypumps Lowcapacitypumps
DESIGN
Relative wear resistance
200
100
50
50
20
10
5
500
200100 1,000 2,000 5,000 10,000 20,000500
[H/f
t]
[Q US GPM]
5
5
10
20
30
150
0
10 50 100 300 1,000 Q l/s
H/m
3085, 3102and 3127
3153, 3171, 3202,3301 and 3315
3231, 3306, 3312, 3356,3400 and 3531
5
Designedandengineeredforlongerlife
SpiN-out™ Seal protectioN For pumpS with cavitieS iN the Seal chamBer
ThepatentedSpin-out™designexpelsabrasiveparticlesfromthesealchamber,providingprotectionagainstwearoftheouterseal.Asanintegralpartofthesealchamber,Spin-out™isassimpleasitiseffective.
XylemspeciallydesignsandmanufacturesFlygtN-pumpcomponents,suchasthemotor,sealsandshaft,tooptimizeoperationandprolongpumpservicelife.
MotorTheClassHsquirrel-cageinductionmotordeliversoutstandingperformanceandsuperiorheattransferinsubmersibleanddryinstallations.Heatlossesareconcentratedaroundtheshrink-fittedstator,whichiscooledbymeansofthesurroundingwater.ThemotorhasaNEMAClassBmaximumoperatingtemperatureriseof80°C(176°F)toensurelongservicelife.Allmotorsarecapableoffullyutilizingtheavailablepowerwhileoperatingonavariablefrequencydrive.
Foranevenhigheroverallefficiency,premiumefficiencymotorsIE3areavailable.
Long-life sealsDurabletungstencarbidesealsofferexceptionalmechanicalstrengthaswellassuperiorslidingpropertiesevenwhenrunningdry.Theselow-frictionsealswithstandthousandsofhoursofhigh-pressureoperationunderextremeconditionswithoutcracking,seizinguporshowingsignsofunacceptablewear.
Low shaft deflectionTominimizevibration,promotequietoperation,andprolongsealandbearinglife,allFlygtN-pumpsfeatureashortshaftoverhangtoreduceshaftdeflection.
6
Asemi-permanentinstallationofapumpwithinaverticalsteelorconcretecolumn.
Forsemi-permanentwetwellinstallations.Thepumpisinstalledwithtwinguidebarsonadischargeconnection.
Avertically-mounted,permanentdrywellorin-lineinstallationwithflangeconnectionsforsuctionanddischargepipework.
Ahorizontally-mounted,permanentdrywellorin-lineinstallationwithflangeconnectionsforsuctionanddischargepipework.
Asemi-permanentfreestandinginstallation.Transportableversionwithpipeorhoseconnection.
Methods of installation
Lowcapacitypumps
ThisseriesofFlygtN-pumpsincludesthreemodelsthathandlecapacitiesupto1,600USGPM(100l/s).LikeallFlygtN-pumps,thesecontributetoreducingthetotallifecyclecostsofyourinstallation.
Power ratings and size
model 3085 3102 3127
rating, hp 2.2–4 5–6 7.5–11
discharge, in 3" (80 mm) 3" (80 mm) 3" (80 mm)
4" (100 mm) 4" (100 mm)
6" (150 mm) 6" (150 mm)
3085, 3102 and 3127
P S T Z L
100
50
20
10
5
50 100 200 500 1,000 2,000
20050
H/m
Q l/s
20
5
5
10
0
10 20 50 100
[H/ft
]
[Q US GPM]
Performance, 60 Hz
30853102
3127
7
Griploc™ sealWitharobustdesign,Griploc™sealsofferconsistentperformanceandtrouble-freeoperationinchallengingenvironments.Solidsealringsminimizeleakageandthepatentedgriplockspring,whichistightenedaroundtheshaft,providesaxialfixationandtorquetransmission.Inaddition,theGriploc™designfacilitatesquickandcorrectassemblyanddisassembly.
Adaptive N-impeller TheFlygtN3085–N3127featureanadaptiveself-cleaningN-impellerthatcanmoveaxiallytoenableeasypassageoflargesolidsthroughthepump.
Better heat traNSFer
Ourspeciallydesignedandmanufacturedmotorprovidesenhancedcoolingbecauseheatlossesareconcentratedaroundthestator.Trickleimpregnatedinresin(ClassHinsulation),thestatorwindingsareratedat180°C(355°F)andenableupto30startsperhour.
compliaNce
Eachpumpistestedandapprovedinaccordancewithnationalandinternationalstandards,including60034-1andCSA.Pumpsareavailableinexplosion-proofversionsforuseinhazardousenvironments,andareapprovedbytheFactoryMutual,EuropeanStandardandIEC.
caBle eNtry
Water-resistantcableentryprovidesbothsealingandstrainrelieffunctionstoensureasafeinstallation.
SeNSorS
Thermalsensorsembeddedinthestatorwindingspreventoverheating.Optionalleakagesensorsinthestatorandoilhousingsarealsoavailable.
loNg-liFe BeariNgS
Durablebearingsprovideaminimumservicelifeof50,000hours.
eNduriNg SealS
TheGriploc™systemconsistsoftwosetsofmechanicalshaftsealsthatoperateindependentlytoprovidedoublesecurityagainstleakage.
TECHNICALDATA
8
Mediumcapacitypumps
Methods of installation
Fordemandingpumpingduties,fivemodelshandlefluidtransportforcapacitiesupto8,000USGPM(500l/s).Highlyefficient,theseheavy-dutymodelsprovideclog-freeperformanceinordertoachievethebestoveralllifecyclecost.
Power ratings and size
model 3153 3171 3202 3301 3315
rating, hp 12–23 25–35 35–75 60–105 85–160
discharge, in 3" (80 mm) 4" (100 mm) 4" (100 mm) 6" (150 mm) 6" (150 mm)
4" (100 mm) 6" (150 mm) 6" (150 mm) 10" (250 mm) 10" (250 mm)
6" (150 mm) 10" (250 mm) 8" (200 mm) 12" (300 mm) 12" (300 mm)
8" (200 mm) 14" (350 mm) 14" (350 mm)
10" (250 mm)
Forsemi-permanentwetwellinstallations.Thepumpisinstalledwithtwinguidebarsonadischargeconnection.
Asemi-permanentfreestandinginstallation.Transportableversionwithpipeorhoseconnection.
Avertically-mounted,permanentdrywellorin-lineinstallationwithflangeconnectionsforsuctionanddischargepipework.
Ahorizontally-mounted,permanentdrywellorin-lineinstallationwithflangeconnectionsforsuctionanddischargepipework.
3153, 3171, 3202, 3301 and 3315
P S T Z
100
50
20
10
5
50 100 200 500
500
1,000 2,000 5,000 10,000 20,000
20050
150
H/m
Q l/s
20
5
5
10
0
10 20 50 100
[H/ft
]
[Q US GPM]
Performance, 60 Hz
3153
3171
3202
3301
3315
9
Flygt Plug-in™ seal with Active Seal™ system TheFlygtPlug-in™sealisasealunitthateliminatestherisksassociatedwithincorrectinstallationandcarelesshandling.ItcomprisestheActiveSeal™systeminoneeasy-to-handleunit.
TheActiveSeal™systemisapatentedzero-leakagedouble-sealsystemthatactivelypreventsliquidfromenteringthemotorcavity,therebyreducingtheriskforbearingandstatorfailure.Itcomprisesaunique
innersealthatactsasamicro-pumpandanoutersealthatpreventsleakageofpumpedmediaintothebufferchamber.
Laser-cutgroovesontheinnersealcreateahydrodynamicpumpingeffectthatpreventsanyleakagefromenteringthemotor.Thistranslatesintoenhancedsealingreliability,reduceddowntimeandfewerunscheduledmaintenancechecks.Inaddition,regularserviceinspectionscanbeprolongedinmanyapplications.
Innersealwithlaser-cutspiralgrooves.
Better heat traNSFer
Ourspeciallydesignedandmanufacturedmotorprovidesenhancedcoolingbecauseheatlossesareconcentratedaroundthestator.Trickleimpregnatedinresin(ClassHinsulation),thestatorwindingsareratedat180°C(355°F)andenableupto30startsperhour.
eFFicieNt cooliNg
Thesepumpsarecooledeitherbythesurroundingliquidor,inmoredemandingapplications,withaninternalclosed-loopcoolingsystem.
iNSpectioN chamBer
Toincreaseoperationalreliability,aninspectionchamberbetweenthesealunitandthebearingsenablesrapidspotchecksandmaintenance.Inthecaseofasealfailure,abuilt-insensorprovidesanearlywarningofanyfluidbuildup,thusreducingtheriskofexpensiverepairwork.
compliaNce
Eachpumpistestedandapprovedinaccordancewithnationalandinternationalstandards,includingIEC60034-1andCSA.Pumpsareavailable
inexplosion-proofversionsforuseinhazardousenvironments,andareapprovedbytheFactoryMutual,EuropeanStandardandIEC.
caBle-eNtry
Water-resistantcableentryprovidesbothsealingandstrainrelieffunctionstoensureasafeinstallation.
SeNSorS
Thermalsensorsembeddedinthestatorwindingspreventoverheating,andaleakagesensorintheinspectionchamberminimizestheriskforbearingandstatorfailure.
loNg-liFe BeariNgS
Durablebearingsprovideaminimumservicelifeof50,000hours.
eNduriNg SealS
TheFlygtPlug-in™sealwiththeActiveSeal™systemoffersincreasedsealingreliabilityandzeroleakageintothemotor,therebyreducingtheriskofbearingandstatorfailure.
TECHNICALDATA
10
P S T Z
Largecapacitypumps
Whenhighercapacityisrequired,theFlygtN-pumpserieshasfivepumpstodothejob.Thesemodelsdeliverunprecedentedpumpingpower–reliablyandefficiently.
Methods of installation
Power ratings and size
model 3231 3306 3312 3356 3400 3531
rating, hp 90–335 70–280 90–470 70–280 60–470 60–870
discharge, in 8" (200 mm) 12" (300 mm) 12" (300 mm) 14" (350 mm) 16" (400 mm) 20" (500 mm)
Forsemi-permanentwetwellinstallations.Thepumpisinstalledwithtwinguidebarsonadischargeconnection.
Asemi-permanentfreestandinginstallation.Transportableversionwithpipeorhoseconnection.
Avertically-mounted,permanentdrywellorin-lineinstallationwithflangeconnectionsforsuctionanddischargepipework.
Ahorizontally-mounted,permanentdrywellorin-lineinstallationwithflangeconnectionsforsuctionanddischargepipework.
3231, 3306, 3312, 3356, 3400 and 3531
100
50
20
10
500
500
1,000 2,000 5,000 10,000 15,000
20050
150
H/m
Q l/s
20
5
50
10
0
100 300 1,000
[H/ft
]
[Q US GPM]
Performance, 60 Hz
3231 3312
3306
3312
3356
3400
3531
11
Zero leakage into the motor cavityTheActiveSeal™systemisapatentedzero-leakagedouble-sealsystemthatactivelypreventsliquidfromenteringthemotorcavity,therebyreducingtheriskforbearingandstatorfailure.Itcomprisesauniqueinnersealthatactsasamicro-pumpandanoutersealthatpreventsleakageofpumpedmediaintothebufferchamber.
Laser-cutgroovesontheinnersealcreateahydrodynamicpumpingeffectthatpreventsanyleakagetoenterthemotor.
Thistranslatesintoenhancedsealingreliability,reduceddowntimeandfewerunscheduledmaintenancechecks.Inaddition,regularserviceinspectionscanbeprolongedinmanyapplications.
CABLEENTRYWater-resistantcableentryprovidesbothsealing
andstrainrelieffunctionsforasafeinstallation.
SENSORSThermalsensorsinthestatorwindingspreventoverheating,andananalogtemperaturesensormonitorsthelowerbearing.Thestatorhousing/leakagechamberandthejunctionboxareequippedwithleakagesensors.Thesensorsdecreasetheriskofbearingandstatorfailure.
LONG-LIFEBEARINGSDurablebearingsprovideaminimumservicelifeof100,000hours.
ENDURINGSEALSTwosetsofmechanicalshaftsealsworkindependentlyfordoublesecurity.TheActiveSeal™systemoffersincreasedsealingreliabilityandzeroleakageintothemotor,therebyreducingtheriskofbearingandstatorfailure.
TECHNICALDATA
Better heat traNSFer
Ourspeciallydesignedandmanufacturedmotorprovidesenhancedcoolingbecauseheatlossesareconcentratedaroundthestator.Trickleimpregnatedinresin(ClassHinsulation),thestatorwindingsareratedat180°C(355°F)andenableupto15startsperhour.
EFFICIENTCOOLINGThesepumpsarecooledeitherbythepumpedliquidorwithaninternalclosed-loopcoolingsystem.
COMPLIANCEEachpumpistestedandapprovedinaccordancewithnationalandinternationalstandards,includingIEC60034-1andCSA.Pumpsareavailableinexplosion-proofversionsforuseinhazardousenvironments,andareapprovedbytheFactoryMutual,EuropeanStandardandIEC.
12
FlygtSmartRun™FlygtMultismart™
Completesolutionsforyourneeds
Ready-to-install pre-engineered, prefabricated pumping solutionsFlygtoffersseveralpackagedsolutionscombiningourpremiumN-pumpswithdedicatedmonitoringandcontroloptionsandpre-fabricatedpumpstationsdesignedforyourneeds.Theprefabricatedpumpstationsareavailableinarangeofdesignsandsizes,allsuppliedcompletewiththenecessarymaterialsandequipmenttoalloweaseandspeedofinstallationandcommissioning.
Ourpackagedsolutionshaveaself-cleaningdesignandaretestedasasystemtoworkperfectlytogethertogiveyoutheultimateperformancewithinwastewaterpumping.
moNitoriNg aNd coNtrol
Ourstate-of-the-artsolutionsaredesignedtoensurepumpsworkatoptimumefficiency,toprovidekeydata,toincreasereliabilityandtopreventpumpbreakdown.
Ourmonitoringandcontrolsystemsaredesignedforuseinavarietyofpumpingapplications.Itisthespecificconditionsateachpumpstationthathelpyoudecidethebestmonitoringandcontrolsolutionforyourneeds.Whetherit’swastewater,stormwater,effluent,RAS,WAS,lightlycontaminatedwaterorcleanwater,italldemandsadifferentsolution.Naturallyeachsystemisdesignedtoworkwellonitsown.However,ourpumpsandmonitoring&controlsystemsareoptimizedtoworkevenbettertogether.
TECHNICALDATA
13
Engineered pumping solutionsFlygt’sstandardpumpstationdesignsarebasedonourlonghistoryinwastewaterpumping.Ourengineersworkcloselywithyou,fromdesignandsystemanalysistoselectionofpumps,installationandmonitoring&controlsolutions.WhetherwerecommendaprovenFlygtstandarddesignordevelopacustomsolutionforyou,wecanofferyoureliableandcost-effectivepumpingsolutionsthatmeetyourspecificrequirements.
AllFlygtmonitoringandcontrolequipmentintegrateeasilyintoSCADAcontrolsystemsforremotemonitoringandcontrol.FlygtPumpViewputsyouinTotalControl,YourWay.
Flygt N-pumpS: SuBmerSiBle aNd dry iNStallatioNS
FlygtN-pumpsareanexcellentchoiceforhandlingsolidsindry-pitinstallations.Originallydesignedforsubmersibleconditions,ourpumpseliminatetheriskofdamagetothemotorduetostationflooding.Submersibleordry-installedFlygtN-pumpsdeliversuperiorclog-freeoperationwithminimalmaintenanceandsubstantialenergysavings.
14
Options tableCustomizeyourFlygtN-pumpwithoptionalequipment.
Thepowertoadapt
SelF cleaNiNg SaveS moNey
Schematicoverviewofcalculationsmadeona30kWFlygtN-pump
PurchasecostEnergycostServicecostUnplannedmaintenancecost
Flygt N-pump model 3085 3102 3127 3153 3171 3202 3301 3315 3231 3306 3312 3356 3400 3531Option/ProductMotor premium efficiency (ie3)Hydraulic guidepin hard-iron™
chopper adaptive N Seal system griploc™ seal plug-in™ seal active Seal™
Spin-out™
Seal flushCooling system 1. w/o cooling jacket 2. closed loop cooling 3. pump media 4. externalInstallation p S t Z lAccessories Flush valvePump monitor Prepared for – mini caS – maSPump control – Smartrun™
– multiSmart™
– Fgc
=Standard=Optional=Standardbutalsooptionaldependingonmodel
=Standardornotavailabledependingonmodel=Optionalornotavailabledependingonmodel
Lifecyclecosts
FlygtN-pump
Conventionalpump2servicecalls/year
Conventionalpump12servicecalls/year
TECHNICALDATA
15
Supportingyourbusiness,everystepoftheway
exteNSive moNitoriNg aNd coNtrol
Wesupplyhardwareandsoftwareforcompleteprocesssystems–fromindividualpumpdrives,starters,sensorsandcontrollerstosystemsoftwareandscalableSCADAsystems.
geNuiNe Flygt Spare partS aNd warraNty
Whendowntimeisn’tanoption,relyonourglobalservicenetworktodelivergenuineFlygtsparepartstoyou–quicklyandefficiently.AllFlygtsparepartsarebackedbyasolid15-yearavailabilityguarantee.Largecapacitypumpsoffera20-yearavailabilityguarantee.
Extensive engineering know-howXylemhasextensiveknowledgeoffluiddynamicsandvastpracticalexperienceindesigning,operatingandmaintainingefficientwastewatertransportsystems.Weprovideabroadrangeofengineeringservices,including:
• Systemanalysisandcalculations• Sumpdesign• Waterhammercalculations• Pumpstartanalysis• Transientanalysis• ComputationalFluidDynamics(CFD)• Scalemodeltesting
Inshort,wecanassistyouwitheverythingyouneedforoptimalperformanceandeconomical,energy-efficientoperation.
Empower your systemWithFlygtmonitoringandcontrolproducts,youcancontrolandoptimizetheperformanceofeverycomponentofyoursystem.Thishelpsreducestressonpumps,valvesandmains,enablereliable,efficientoperation,andprolongservicelifetime.
SUPPORT&SERVICE
Support for your Flygt pumpsOurglobalnetworkoflocalservicecentersandservicepartnersprovideintegratedservicestosupportsafe,efficientandreliableoperation.Toensuretrouble-freeoperationandminimaldowntime,countonusforquick,professionalresponseandqualitymaintenanceservices,usinggenuineFlygtspareparts.
FB002•FlygtN-PumpSeriesBrochure•7/2015•NACT
1)Thetissueinplantsthatbringswaterupwardfromtheroots2)AleadingglobalwatertechnologycompanyWe’re12,000peopleunifiedinacommonpurpose:creatinginnovativesolutionstomeetourworld’swaterneeds.Developingnewtechnologiesthatwillimprovethewaywaterisused,conserved,andre-usedinthefutureiscentraltoourwork.Wemove,treat,analyze,andreturnwatertotheenvironment,andwehelppeopleusewaterefficiently,intheirhomes,buildings,factoriesandfarms.Inmorethan150countries,wehavestrong,long-standingrelationshipswithcustomerswhoknowusforourpowerfulcombinationofleadingproductbrandsandapplicationsexpertise,backedbyalegacyofinnovation.FormoreinformationonhowXylemcanhelpyou,gotoxyleminc.com.
Xylem,Inc.14125SouthBridgeCircleCharlotte,NC28273Tel704.409.9700Fax704.295.9080855-XYL-H2O1(855-995-4261)www.xyleminc.com
FlygtisatrademarkofXylemInc.oroneofitssubsidiaries.©2015Xylem,Inc.JULY2015