6 April 2004 1
PXL-500/-510
Tiger Controller II
![Page 2: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/2.jpg)
6 April 2004 2
The PXL-500 Controller
• Manages up to 65,535 cardholders
• Buffers up to 3,640 events– Events stored in FIFO
(First-In-First-Out) order
![Page 3: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/3.jpg)
6 April 2004 3
The PXL-500 Controller
• Controller addressing via push-button and LEDs
• NO dip switches to set
![Page 4: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/4.jpg)
6 April 2004 4
The PXL-500 Controller
• Auto configuration:– Doors software
automatically downloads controller/network information - no manual data entry
– Controller network termination
![Page 5: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/5.jpg)
6 April 2004 5
The PXL-500 Controller
• Auto configuration:– Controller
communication mode (direct connect, modem, Ethernet)
– SB-593 Satellite board installation
![Page 6: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/6.jpg)
6 April 2004 6
The PXL-500 Controller
• Inputs and Outputs are transient protected
• Handles either– 1 or 2 Readers for single
door In/Out controlOR
– Two doors using optional SB-593 Satellite board
![Page 7: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/7.jpg)
6 April 2004 7
Power Specifications
• Power - 12 VDC @ 1 A– Worst case current draw – with all features
and options active
• Current Draw– 120 mA for the PXL-500– 150 mA for an SB-593– 50 mA to 200 mA dependent upon reader type1
– 200 mA for a LAN-500
• Relay Contact Rating - 1A @ 24 VDC
1 – Wiegand readers may draw more current, refer to the reader’s manual for specifics
![Page 8: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/8.jpg)
6 April 2004 8
Wiring Specifications
• RS-232 Serial Communication Cable– 3 conductor, shielded, stranded, AWG-24
50 feet maximum run length (per RS-232 spec)
• RS-485 Controller Network Cable– 1-pair, twisted, shielded, stranded, AWG-24
16,000 feet total network run length
![Page 9: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/9.jpg)
6 April 2004 9
Wiring Specifications
• Controller Power– 2 conductor, stranded, AWG-18– 200 feet maximum run length
• Earth Ground– Single conductor, AWG-18 (or larger gauge)– Minimize run length for best grounding conditions
![Page 10: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/10.jpg)
6 April 2004 10
Wiring Specifications
• Input and Output Lines– 2 conductor, stranded, AWG-22– 500 feet maximum run length
• Readers– 6 conductor, shielded, stranded (for Keri Prox)– 4 to 7 conductor, shielded, stranded
(for Wiegand, by reader type)– MS-3000, MS-4000, MS-5000
• 500 feet maximum run length with AWG-24
– MS-7000• 500 feet maximum run length with AWG-20
![Page 11: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/11.jpg)
6 April 2004 11
Typical Application Diagram
![Page 12: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/12.jpg)
6 April 2004 12
Block Diagram - Communication
RS-485ControllerNetwork
RS-232PC to
MasterController
LAN-500Ethernet
PXL-510Alarm Panel
PXL-510Serial Port
![Page 13: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/13.jpg)
6 April 2004 13
Block Diagram
ReaderConnections
EE Prom
UnitProtection
![Page 14: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/14.jpg)
6 April 2004 14
Block Diagram
AddressLED
Battery
StatusLEDs
![Page 15: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/15.jpg)
6 April 2004 15
Controller Block Diagram
Unit Power
Inputsand
Outputs
SelectionSwitch
![Page 16: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/16.jpg)
6 April 2004 16
PCB Features
• Microprocessors
– CPU to manage controller general operation
– RISC* processor to manage I/O processing
– RISC* processor to manage the Reader receivers
* (Reduced Instruction Set Computer )
![Page 17: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/17.jpg)
6 April 2004 17
PCB Features
• Socketed EE Prom and PIC– Quick, easy firmware
updates
• Battery– 5-year, Lithium
![Page 18: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/18.jpg)
6 April 2004 18
PCB Features
• Quick disconnect terminals for all wiring connections
• Unique RS-485 connector– easily distinguish
network connectionfrom other connections
• Red power connector– easily distinguish power
from other connections
![Page 19: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/19.jpg)
6 April 2004 19
Certifications
• CE Declaration of Conformity
• C-Tick
• CSA C22.2 No. 142
• UL 508 Part XVII
• FCC
![Page 20: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/20.jpg)
6 April 2004 20
Communications - PC to Master Controller
• RS-232 serial port (TB-12)– Controller automatically
detects connection type
![Page 21: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/21.jpg)
6 April 2004 21
Communications - PC to Master Controller
– Via direct serial connection
OR
– Via a pair of modems
![Page 22: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/22.jpg)
6 April 2004 22
Communications - PC to Master Controller
• Optional, plug-in TCP/IP module (TB-13)– Controller automatically detects TCP/IP connection– Jumpers reconfigure communication
![Page 23: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/23.jpg)
6 April 2004 23
Communications - Inter-Controller Network
• RS-485 serial port (TB-1)– Auto-configuration of network termination– Total network length up to 16,000 feet– Network configuration flexibility
• “T” and “star” configurations
– Single, twisted-pair, shielded cable– Link up to 128 controllers and 256 doors
![Page 24: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/24.jpg)
6 April 2004 24
Communications - Options
• PXL-510 – with second serial COM port– Used as the Alarm Panel interface (TB-11), connecting to
Caddx NX8E alarm panels
![Page 25: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/25.jpg)
6 April 2004 25
Inputs
• Inputs (TB-4)– Door Status– Request to Exit– Global Unlock (1)
or– Aux/Secondary RTE (2)
(1) Master controller only
(2) Master or slave controllers
![Page 26: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/26.jpg)
6 April 2004 26
Outputs
• Form-C Output Relays (TB-3)– Door Lock– Alarm
• In a Form-C relay, the common always creates a complete circuit with either– The normally-open
contactOR
– The normally-closed contact
![Page 27: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/27.jpg)
6 April 2004 27
Readers
• 2 Reader ports per Controller
• Controls either 1 or 2 doors– In / Out control of 1 door– 2-door control with
optional SB-593 board
![Page 28: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/28.jpg)
6 April 2004 28
Readers - PXL-500P
• Exclusively for MS-Series Proximity Readers– MS-3000– MS-4000– MS-5000– MS-7000
A-Reader: Single Door, In Door, or Door 1 (TB-5)
B-Reader: Out Door or Door 2with SB-593 (TB-6)
![Page 29: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/29.jpg)
6 April 2004 29
Readers - PXL-500W
• For Wiegand compatible reader technologies– Pyramid Associates
Readers (P-300, P-400, P-500, P-600, P-700)
– Bar code, mag-stripe, biometric, etc.
A-Reader: Single Door, In Door, or Door 1 (TB-5)
B-Reader: Out Door or Door 2with SB-593 (TB-6)
![Page 30: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/30.jpg)
6 April 2004 30
Readers - PXL-500W
• Warning LED (LED-10)– Lights when 12 VDC is selected (as shown in picture)– Protects 5 VDC readers from over-voltage condition
• Jumper selectable (JP-5) for either 5 or 12 VDC Wiegand readers (5 VDC is the factory setting)
![Page 31: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/31.jpg)
6 April 2004 31
Unit Addressing
• LED Display– Address displayed via easy-to-read
LEDs– Provides diagnostic information– Displays over or under supply voltage
value
![Page 32: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/32.jpg)
6 April 2004 32
Unit Addressing
• Selection Button (S1)
– Set unit address• no DIP or rocker switches
• no PC pre-configuring
– Select diagnostic options
![Page 33: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/33.jpg)
6 April 2004 33
Unit Reset
• Reset Jumper (JP3)– Clears unit memory and resets unit– Used in conjunction with S1
![Page 34: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/34.jpg)
6 April 2004 34
Master versus Slave Operation
• Master Controller– Must be assigned address “01”– Manages communication between host PC
and the controller network– Handles presentation card enrollment (using
A-Reader), Show Photo, and ID Card features
• Slave Controllers– Can be assigned any other unique address
from “02” to “128”– Do not have to be addressed in sequential order
![Page 35: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/35.jpg)
6 April 2004 35
Status LEDs
• TXD and RXD for RS-232– LEDs 2 and 3 for primary
serial port– LEDs 4 and 5 for optional
serial port– LEDs flicker red/green as
data is transferred
![Page 36: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/36.jpg)
6 April 2004 36
Status LEDs
• Lock Relay– Lights when relay is active
• Alarm Relay– Lights when relay is active
![Page 37: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/37.jpg)
6 April 2004 37
Status LEDs
• Power– Lights GREEN when power
is ON and OK– Lights RED when power is
over or under specification
• Communications for RS-485– Flickers red/green as data is
transferred
![Page 38: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/38.jpg)
6 April 2004 38
System Protection
• The PXL-5xx controller has the following system protection features:– Metal-oxide Varistors– Transorbs– Gas Discharge Tube– Fused over/under voltage detection– Power status LEDs– Socketed RS-485 IC
![Page 39: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/39.jpg)
6 April 2004 39
System Protection
• Power Status (Fuse) LED– Warns the installer of
unsafe power conditions– Glows RED if power is
reversed– Glows GREEN if there
is a power line short or an over current draw condition
![Page 40: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/40.jpg)
6 April 2004 40
System Protection
• Gas Discharge Tube– Protect the PCB from
damage caused by transients and power surges
• MOVs – Protect relays from
damage caused by transients and power surges
![Page 41: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/41.jpg)
6 April 2004 41
System Protection
• Socketed RS-485 communication IC– For quick repair of
damage caused by voltage spikes
![Page 42: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/42.jpg)
6 April 2004 42
System Protection
• Thermal Fuse opens under unsafe power or current conditions
• CAUTION – Do not touch this component, it is very hot during operation
![Page 43: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/43.jpg)
6 April 2004 43
System Protection
• Transorbs protect all signal inputs from damage caused by transients and power surges
![Page 44: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/44.jpg)
6 April 2004 44
Environmental Operating Range
• Temperature– 0° to 140 °F (-18° to 60° C)
• Humidity– 0% to 90% relative humidity, non-condensing
![Page 45: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/45.jpg)
6 April 2004 45
SB-593 Satellite Expansion Board
• Jumper selectable for either:– Second door control with
2 programmable outputs and 6 programmable inputs
OR– 4 programmable outputs
and 8 programmable inputs
• Uses Form C relays
![Page 46: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/46.jpg)
6 April 2004 46
SB-593 Satellite Expansion Board
• Snaps into place on the PXL-500 controller– align header connectors
and plastic mounting pins to corresponding locations on controller and press into place
• Installation LEDs– indicates correct board
installation
![Page 47: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/47.jpg)
6 April 2004 47
SB-593 Satellite Expansion Board
• Controller auto-detects an installed SB-593– no additional
configuration needed
• Status LEDs– Indicate relay
active/inactive status
• Relay Contact Rating– 1A @ 24 VDC
![Page 48: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/48.jpg)
6 April 2004 48
Options - LCD-1
• LCD-1 - plug-in liquid-crystal display for:– Firmware revision– Date and time– Diagnostic information
![Page 49: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/49.jpg)
6 April 2004 49
Options - LAN-50/100/500
• Provides low cost TCP/IP communication using either:– LAN-50/100 external modules– LAN-500 plug-in module
• IT experience required for proper configuration of LAN device
![Page 50: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/50.jpg)
6 April 2004 50
Options - Alarm Panel Interface
• Fully integrated access and alarm panel control using the secondary serial port on the PXL-510 panel
• Interfaces with the Caddx NX-8E alarm panel
![Page 51: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/51.jpg)
6 April 2004 51
Options - Alarm Panel Interface
• Use Doors software to: – Easily manage access
and alarm panel users– Report alarm system
activity
• Arm/disarm alarm system using access system Readers
![Page 52: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/52.jpg)
6 April 2004 52
Options - Video Badging
• Fully integrated access control and badging
• Design and print badges with photos and custom graphics
• Keri also offers a Badging Service
![Page 53: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/53.jpg)
6 April 2004 53
Options - Video Badging
• Single database entry point for user access and badging information
• On-demand badge holder photo display
![Page 54: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events](https://reader036.vdocuments.us/reader036/viewer/2022062518/56649cd85503460f949a170f/html5/thumbnails/54.jpg)
6 April 2004 54
Integrated Telephone Entry
• Entraguard Gold– Fully integrated access control and telephone entry using
Keri’s Entraguard product line– Easily manage access and telephone entry users via Keri’s Doors software
– Either in radiant keypad or mechanical keypad versions