55175911 hybrid microwave configuration guide for du hspa
TRANSCRIPT
HUAWEI TECHNOLOGIES CO., LTD.
www.huawei.com
Huawei Confidential
Security Level: 23/4/11
英文标题 :40-47pt
副标题 :26-30pt
字体颜色 : 反白内部使用字体 :
FrutigerNext LT Medium
外部使用字体 : Arial
中文标题 :35-47pt
字体 : 黑体 副标题 :24-28pt
字体颜色 : 反白字体 : 细黑体 For Huawei Engineer
Hybrid Microwave Configuration Guide for du
HSPA+ Project
英文目录标题 :35-40pt
颜色 : R153 G0 B0
内部使用字体 :
FrutigerNext LT Medium
外部使用字体 : Arial
中文目录标题 :35-40pt
颜色 : R153 G0 B0
字体 : 黑体
英文目录正文 :28-30pt
子目录 (2-5 级 ) :20-30pt
颜色 : 黑色内部使用字体 :
FrutigerNext LT Regular
外部使用字体 : Arial
中文目录正文 :28-30pt
子目录 (2-5 级 ):20-30pt
颜色 : 黑色字体 : 细黑体
Content
• Hybrid Microwave Parameters Configuration
• Ethernet Services Configuration
• Services Convergence between 2 EMS6
HUAWEI TECHNOLOGIES CO., LTD. Page 3Huawei Confidential
Content
Hybrid Microwave Parameters Configuration Ethernet Services Configuration Services Convergence between 2 EMS6
HUAWEI TECHNOLOGIES CO., LTD. Page 4Huawei Confidential
Hybrid Microwave Parameters Configuration
Create the IF 1+1 protectionCreate the IF 1+1 protection
Set the RF parametersSet the RF parameters
Set attributes of the Hybrid microwave/AM
Set attributes of the Hybrid microwave/AM
Configure the Ethernet portConfigure the Ethernet port
Configure the Ethernet serviceConfigure the Ethernet service
Create an NE to be logged in
Create an NE to be logged in
Modify the NE IDModify the NE ID
Add logicalboards
Add the NE againAdd the NE again
Create a LAGCreate a LAG
Difference when the configuration of Hybrid microwave is compared with the configuration of traditional microwave
The three procedures are called "configuring a LAG.
• Configuration Flow
HUAWEI TECHNOLOGIES CO., LTD. Page 5Huawei Confidential
Hybrid Microwave Parameters Configuration
• Create the IF 1+1 Protection
HUAWEI TECHNOLOGIES CO., LTD. Page 6Huawei Confidential
• Create the IF 1+1 Protection
If only one IF 1+1 protection group is created, set the Protection Group ID parameter to 1. If two IF 1+1 protection groups are created, it is recommended that you set the Protection Group ID parameter for the protection group consisting of the IF boards in slot 5 and in slot 7 to 1 and set the Protection Group ID parameter for the protection group consisting of the IF boards in slot 6 and in slot 8 to 2.
HUAWEI TECHNOLOGIES CO., LTD. Page 7Huawei Confidential
• Create the IF 1+1 Protection
The IF 1+1 protection group is already created.
HUAWEI TECHNOLOGIES CO., LTD. Page 8Huawei Confidential
• Set RF Parameters The IF 1+1 protection group that is created is displayed.
HUAWEI TECHNOLOGIES CO., LTD. Page 9Huawei Confidential
• Set RF Parameters
You can set the link ID and ATPC attributes for the main IF board. The IF working mode of the Hybrid microwave cannot be set on this interface.
Set the transmit frequency and the transmit power.
HUAWEI TECHNOLOGIES CO., LTD. Page 10Huawei Confidential
• Set RF Parameters The transmit frequency and the transmit power for the standby ODU in a 1+1 HSB/SD protection group need not be set. The system automatically copies the configuration information about the main ODU for the standby ODU. The information about the standby ODU in a 1+1 FD protection group needs to be configured.
The information about the standby IF board in a 1+1 HSB/SD/FD protection group need not be configured. The system automatically copies the configuration information about the main IF board for the standby IF board.
HUAWEI TECHNOLOGIES CO., LTD. Page 11Huawei Confidential
• Set Attributes of the Hybrid Microwave/AM
HUAWEI TECHNOLOGIES CO., LTD. Page 12Huawei Confidential
The IF channel bandwidth and the modulation mode of the assured AM service capacity determine the value of assured E1 capacity.
• Set Attributes of the Hybrid Microwave/AM
HUAWEI TECHNOLOGIES CO., LTD. Page 13Huawei Confidential
• Set Attributes of the Hybrid Microwave/AM
Set these parameters according to the network planning documents.
By default, the AM function of the IFH2 board is disabled.
The value of the E1 Capacity parameter should not be more than the maximum value of the Assured E1 Capacity parameter in the modulation mode of the assured AM service capacity.
HUAWEI TECHNOLOGIES CO., LTD. Page 14Huawei Confidential
• Set Attributes of the Hybrid Microwave/AM If the set value of the E1 Capacity
parameter is more than the value of the Assured E1 Capacity parameter, the system displays a prompt.
HUAWEI TECHNOLOGIES CO., LTD. Page 15Huawei Confidential
• Configure a LAG
IFH2
IFH2
EMS6
To the external equipment
Configure the GE
interface of the IFH2 board
Configure the QoS Create a LAG
The GE interface of the IFH2 board in slot 5 and the GE interface of the IFH2 in slot 7 are connected to port 1 and port 2 of the EMS6 board respectively. Because the IFH2 board in slot 5 functions as the main board and the IFH2 board in slot 7 functions as the standby board, port 1 of the EMS6 board functions as the main port and port 2 functions as the slave port. Port 3 of the EMS6 board is connected to the external equipment.
Configure the external
interface of the EMS6 board
Configure the Ethernet
service of the EMS6 board
HUAWEI TECHNOLOGIES CO., LTD. Page 16Huawei Confidential
• Configure a LAG
Enable the GE interface of the IFH2 board.
Create a LAG
Configure the GE interface of the IFH2
board
Configure the external interface
of the EMS6 board
Configure the Ethernet service
of the EMS6 board
HUAWEI TECHNOLOGIES CO., LTD. Page 17Huawei Confidential
• Configure a LAGThe IFH2 board in slot 7 functions as the standby board. Hence, this board need not be configured. Instead, the system automatically copies the information about the main IF board for the standby board, including the Ethernet information.
The GE interface of the IFH2 board in slot 5 (main IF board) is enabled. Hence, the GE interface of the IFH2 board in slot 7 (standby IF board) is automatically enabled by the system.
Create a LAG
Configure the GE interface of the IFH2
board
Configure the external interface
of the EMS6 board
Configure the Ethernet service
of the EMS6 board
HUAWEI TECHNOLOGIES CO., LTD. Page 18Huawei Confidential
• Configure a LAG
Note: Select External Port.
Create a LAG
Configure the GE interface of the IFH2
board
Configure the external interface
of the EMS6 board
Configure the Ethernet service
of the EMS6 board
HUAWEI TECHNOLOGIES CO., LTD. Page 19Huawei Confidential
• Configure a LAG
Port 1 to port 3 are used. Hence, enable them. Port 4 to port 6 are not used. Hence, disable these ports to prevent the ETH_LOSS alarm.
Create a LAG
Configure the GE interface of the IFH2
board
Configure the external interface
of the EMS6 board
Configure the Ethernet service
of the EMS6 board
HUAWEI TECHNOLOGIES CO., LTD. Page 20Huawei Confidential
• Configure a LAGCreate a
LAG
Configure the GE interface of the IFH2
board
Configure the external interface
of the EMS6 board
Configure the Ethernet service
of the EMS6 board
HUAWEI TECHNOLOGIES CO., LTD. Page 21Huawei Confidential
• Configure a LAG
Create a LAG
Configure the GE interface of the IFH2
board
Configure the external interface
of the EMS6 board
Configure the Ethernet service
of the EMS6 board
HUAWEI TECHNOLOGIES CO., LTD. Page 22Huawei Confidential
• Configure a LAGCreate a
LAG
Configure the GE interface of the IFH2
board
Configure the external interface
of the EMS6 board
Configure the Ethernet service
of the EMS6 board
HUAWEI TECHNOLOGIES CO., LTD. Page 23Huawei Confidential
• Configure a LAG
Create a LAG
Configure the GE interface of the IFH2
board
Configure the external interface
of the EMS6 board
Configure the Ethernet service
of the EMS6 board
HUAWEI TECHNOLOGIES CO., LTD. Page 24Huawei Confidential
• Configure a LAGCreate a
LAG
Configure the GE interface of the IFH2
board
Configure the external interface
of the EMS6 board
Configure the Ethernet service
of the EMS6 board
HUAWEI TECHNOLOGIES CO., LTD. Page 25Huawei Confidential
• Configure a LAG
The LAG number and name are set according to the design.
In the case of the IF 1+1 protection, set the LAG to a manual LAG using the non-sharing mode.
The port that is connected to the main IFH2 board functions as the main port. The port that is connected to the standby IFH2 board functions as the slave port.
Create a LAG
Configure the GE interface of the IFH2
Configure the external interface
of the EMS6
Configure the Ethernet service
of the EMS6
HUAWEI TECHNOLOGIES CO., LTD. Page 26Huawei Confidential
Content
Hybrid Microwave Parameters Configuration Ethernet Services Configuration Services Convergence between 2 EMS6
HUAWEI TECHNOLOGIES CO., LTD. Page 27Huawei Confidential
Ethernet Services Configuration
• Configuration Flow
Create EPLAN ServiceCreate EPLAN Service
Create VB with the type of 802.1dCreate VB with
the type of 802.1d
Mount the Ports for VBMount the Ports for VB
Configure the Ports’ AttributesHub/Spoke
Configure the Ports’ AttributesHub/Spoke
Enable PortsEnable Ports
Configure the Ports Work Mode
Configure the Ports Work Mode
Configure the Tag AttributesConfigure the Tag Attributes Bind the Flow to CoSBind the Flow to CoS
Create a FlowCreate a Flow
Configure the CoSConfigure the CoS
Configure the Ports
Configure the Ethernet Services
Configure the QoS of EMS6
Board
HUAWEI TECHNOLOGIES CO., LTD. Page 28Huawei Confidential
Configure the Ports• Configure the External Ports
In the NE Explorer, select the EMS board, and then
choose Configuration > Ethernet Interface Management >
Ethernet Interface from the Function Tree. The
configuration window for internal ports is displayed by
default. Select External Port.
HUAWEI TECHNOLOGIES CO., LTD. Page 29Huawei Confidential
Set the port that accesses services to Enabled. Set other ports to Disabled.
Set Working Mode to the default value (Auto-Negotiation).
Set Maximum Frame Length to the default value (1522).
Configure the Ports• Ports Enable and Working Mode
HUAWEI TECHNOLOGIES CO., LTD. Page 30Huawei Confidential
Click the TAG Attributes tab. This tab is unavailable if the EFT4 is used.
TAG: Set this parameter based on the type of the frames processed by the port.
This parameter is valid only when the TAG parameter is set to Access or Hybrid. Set this parameter according to actual applications.
This parameter defines whether or not to detect the packets from the port according to the TAG attributes. Generally, set this parameter to the default value (Enabled).
Configure the Ports• Configure the TAG Attributes
HUAWEI TECHNOLOGIES CO., LTD. Page 31Huawei Confidential
Configure the Ethernet Services• Create Ethernet LAN Services
HUAWEI TECHNOLOGIES CO., LTD. Page 32Huawei Confidential
Configure the Ethernet Services• Create the VB with the Type of 802.1d
Select the Bridge Switch
Mode as 820.1d
HUAWEI TECHNOLOGIES CO., LTD. Page 33Huawei Confidential
Configure the Ethernet Services• Mount the Ports for VB Select the ports
which are used in this ESM6
board
HUAWEI TECHNOLOGIES CO., LTD. Page 34Huawei Confidential
Configure the Ethernet Services• Mount the Ports for VB
HUAWEI TECHNOLOGIES CO., LTD. Page 35Huawei Confidential
Configure the Ethernet Services• Configure the Ports Attributes
According to the requirements, select the Hub/Spoke attribute for each port:Convergence Port will be configured as
Hub;Other ports will be configured as
Spoke.
HUAWEI TECHNOLOGIES CO., LTD. Page 36Huawei Confidential
Configure the QoS of EMS6• Create a Flow
HUAWEI TECHNOLOGIES CO., LTD. Page 37Huawei Confidential
Configure the QoS of EMS6• Create a Flow
Configure a Port Flow for each Port.
HUAWEI TECHNOLOGIES CO., LTD. Page 38Huawei Confidential
Configure the QoS of EMS6• Create a Flow
One PortOne Flow
HUAWEI TECHNOLOGIES CO., LTD. Page 39Huawei Confidential
Configure the QoS of EMS6• Configure the CoS
HUAWEI TECHNOLOGIES CO., LTD. Page 40Huawei Confidential
Configure the QoS of EMS6• Configure the CoS The CoS Type
should be VLAN Priority
HUAWEI TECHNOLOGIES CO., LTD. Page 41Huawei Confidential
Configure the QoS of EMS6• Configure the CoS
Configure the CoS Priority as:User Priority 2 and 5 in VLAN Tag are corresponded with
CoS Priority 2 and 5.Others should be configured
as 0.
HUAWEI TECHNOLOGIES CO., LTD. Page 42Huawei Confidential
Configure the QoS of EMS6• Bind the Flow to CoS
Each Flow should be
bound with one CoS.
HUAWEI TECHNOLOGIES CO., LTD. Page 43Huawei Confidential
Content
Hybrid Microwave Parameters Configuration Ethernet Services Configuration Services Convergence between 2 EMS6
HUAWEI TECHNOLOGIES CO., LTD. Page 44Huawei Confidential
Services Convergence between 2 EMS6
• Hardware Structure
7-IFH2 TO SiteDS
5-IFH2 TO SiteDM
3-PXC
1-PXC
6-EMS6
4-EMS6
2-SCC
FANSlot20
POP Optical Equipments(OSN3500)
From Other IDU (EMS6-GE)
All the Ethernet services should be
converged to 4-EMS6
HUAWEI TECHNOLOGIES CO., LTD. Page 45Huawei Confidential
Services Convergence between 2 EMS6
• Configuration Flow
Create EPLAN Service(802.1d Bridge)
Create EPLAN Service(802.1d Bridge)
Mount Ports for VBMount Ports for VB
Bound path for VCTRUNKBound path
for VCTRUNKConfigure Hub/Spoke Attribute for VB PortsConfigure Hub/Spoke Attribute for VB Ports
Create aCross-connection
Create aCross-connection
HUAWEI TECHNOLOGIES CO., LTD. Page 46Huawei Confidential
Services Convergence between 2 EMS6
• Create EPLAN Service
Input the name of VB and select type
of 802.1d.
HUAWEI TECHNOLOGIES CO., LTD. Page 47Huawei Confidential
Services Convergence between 2 EMS6
• Mount Ports for VB Select the ports which should be
mounted with this VB according to
hardware structure
HUAWEI TECHNOLOGIES CO., LTD. Page 48Huawei Confidential
Services Convergence between 2 EMS6
• Bound Path for VCTRUNK
VC3-xv level path should be selected
for bounding VCTRUNK
HUAWEI TECHNOLOGIES CO., LTD. Page 49Huawei Confidential
Services Convergence between 2 EMS6
• Bound Path for VCTRUNK
According to design, all the 6 VC3 should be bounded.
HUAWEI TECHNOLOGIES CO., LTD. Page 50Huawei Confidential
Services Convergence between 2 EMS6
• Bound Path for VCTRUNK
Mounted ports and bounded path
HUAWEI TECHNOLOGIES CO., LTD. Page 51Huawei Confidential
Services Convergence between 2 EMS6
• Configure Hub/Spoke Attribute for VB Ports
Select the Hub/Spoke attribute for each port according to design
HUAWEI TECHNOLOGIES CO., LTD. Page 52Huawei Confidential
Services Convergence between 2 EMS6
• Configure Hub/Spoke Attribute for VB Ports
Convergence ports configured as Hub;Access ports configured as Spoke
HUAWEI TECHNOLOGIES CO., LTD. Page 53Huawei Confidential
Services Convergence between 2 EMS6
• Configure EPLAN service on another EMS6
The bounded path should be the same as the previous EMS6
HUAWEI TECHNOLOGIES CO., LTD. Page 54Huawei Confidential
Services Convergence between 2 EMS6
• Mount Ports and Bound Path
Configure the Hub/Spoke attribute for the mounted ports
HUAWEI TECHNOLOGIES CO., LTD. Page 55Huawei Confidential
Services Convergence between 2 EMS6
• Create a Cross-connection
1/ The level should be VC3;2/ The source and the sink of the service should be 4-EMS and 6-EMS;3/ The timeslot of source and sink should be the same.
HUAWEI TECHNOLOGIES CO., LTD. Page 56Huawei Confidential
Services Convergence between 2 EMS6
• Create a Cross-connection
Create the same cross-connection of VC4-2 between 4-EMS and 6-EMS.
HUAWEI TECHNOLOGIES CO., LTD. Page 57Huawei Confidential
Services Convergence between 2 EMS6
• Create a Cross-connection
Thank youwww.huawei.com