    Basic command for 2G BTS

    1. For UP/DOWN Status-

    RLCRP: CELL=ALL ;( if shows 0 for all value site/sector will be down)

    2. If site down check the condition of PCM if it is ABL (not working) verify theloop test to identify the fault and if PCM is working check the alarm on BTS.

    3. For finding the PCM use command-

    RXTCP: MOTY=RXOTG, CELL=cell; (cell id with sector i.e

    BST001A)

    It gives TG VAULE

    RXAPP: MO=RXOTG-tg $; (tg$ is TG VALUE)

    It gives device no. use last device

    RADEP: DEV=dev$; (dev$ is device value i.e

    RBLT-2719)

    It gives SNT value

    NTCOP: SNT=snt$;

    Find the device no that is used in dev$ and corresponding vaule of DIP

    4. Check the status of PCM

    DTSTP: DIP=dip$; (dip$ is DIP VALUE i.e 83RBLT)

    DTQDP: DIP=dip$; & DTQUP: DIP=dip$; (FOR finding error on PCM,

    Check the value of es, ses uas & SLIP ,these value must be 0 or constant)

    5. If PCM condition found working then BLOCK /DEBLOCK to get managed object

    in working condition use command

    RXBLI:MO=mo$,subord,force;

    RXESE:MO=mo$,subord;

    RXESI:MO=mo$,subord;

    RXBLE:MO=mo$,subord;

    (mo$ - RXOTG-tg$, RXOCF-tg$, RXOCON -tg$ ,RXOIS-tg$,RXOTRX-tg$-tei

    value ,RXOTX-tg$- tei value,RXORX-tg$- tei value,RXOTS-tg$-tei value-time

    slot no)

    Page 1 of4

  • 7/27/2019 52571941-Basic-command-for-2G-BTS.pdf

    2/4

    6. For finding the faulty managed object use command

    RXASP: MO=RXOTG- tg$;

    This alarm list contains various alarms like BTS INT UNAFFECTED, BTS INT

    AFFECTED, PERMANENT FAULT, some alarms can be removed by using

    BLOCK/DEBLOCK commands.

    7. For finding fault code on particular managed object (mo) use

    RXMFP: MO=mo$;

    This command shows fault code class and code some description is bellow

    IF mo$ is RXOCF then FAULT CODE IS

    2A-33 RX diversity lost2A-8 VSWR limits exceeded

    2A-57 RX PATH IMBLANCE (VSWR)2A-39 RX cable disconnected (Related faults: RXORX 1B:9 - RX cable

    disconnected)2A:7 RXDA amplifier current faults (CDU FAULTY Need replacement)

    2A-21 internal power capacity reduced (PSU unit faulty or power off)2A-41 lost communication to TRU2A:23 Climate capacities reduced (Check fans and the Fan Control Unit)2A:9 Power limits exceeded (Related faults: RXOTX 1B:2 TRU faulty need

    replacement)

    If mo$ is RXOTRX then fault code is

    1A-13 TX saturation (TRU FAULTY Need replacement)2A-12 TX output power limits exceeded (Related faults: TX 1B:13)

    block/deblock unit if not work Change TRU2A-13 TX saturation (Related faults: TX 1B:14 - TX saturation)

    block/deblock unit if not work Change TRU2A:25 TX max power restricted block /deblock unit if not work Change TRU2A:43 internal configuration fail block /deblock unit if not work Change TRU2A:42 Hardware IDB inconsistent check combiner chip & then IDB

    Any alarm found other than mentioned above on any manage object then pleaseconsult with MSC Gorakhpur

    8. FOR replacement of TRUFirst get local mode on TRU by pressing Local /Remote button on TRU2nd power off the TRU3RD with the help of T10 Screw driver open the 2 pair screw on upper/lowerend of unit4th replace the faulty unit with new one5th power on and wait until Local Lamp get constant glow6th again get remote status by pressing Local /Remote button on TRU

    Page 2 of4

  • 7/27/2019 52571941-Basic-command-for-2G-BTS.pdf

    3/4

    Wait for operation condition by 5minute if not operational block/deblock fromBSC if not work contact with MSC Gorakhpur

    Same processors adopt for CDU replacement (except Local/remote)Caution must be taken for wiring of units

    Tools (basic) used for hardware replacement are-

    32 wrench8/9 wrenchNoze pliers

    T10T8

    For analysis of TCH BLOCKING1. Find that site working in full configuration by using command

    RXCDP: MO=RXOTG-tg$; (ALL mo must be configured)If any BLOCKED found then use commandRXASP: MO=RXOTG-tg$; (to find the all alarm and reason of block)IF LOCAL MODE found than try to make REMOTE otherwiseCheck the fault code by command

    RXMFP:MO=mo$; (to find the exact fault code to make decision thathardware if faulty or not if hardware is faulty and need replacement thenbook the fault to ericsson and if the hardware is not faulty the

    BLOCK/DEBLOCK to make unit operational )If any mo not block then check the half rate is on or offFor checking half rate use commandRLDHP: CELL=cell; (DHA=ON)If DHA not ON use command to on itRLDHC: CELL=cell, DHA=ON;If traffic is more than for witch site is configured (as erlang B table ) then

    increase the value of half rate by using commandRLDHC: CELL=cell, DTHAMR=100, DTHNAMR=100;

    Erlang B tableTRU (Per sector) Traffic that supported on full rate

    1 2.2E2 8.0E3 14.5E4 21.4E5 28.5E6 35.8E7 43.1E8 50.5E

    If none of the above case so new BTS is required to release congestion

    Page 3 of4

  • 7/27/2019 52571941-Basic-command-for-2G-BTS.pdf

    4/4

    For analysis of TCH DROP/CALL DROP1. find alarm of RXOCF i.e VSWR or RX diversity lost if present the get rectify it2. find alarm of TRU if any alarm the get rectified3. use command RLCRP:CELL=cell; and in output see the ICM band must be 1

    to 3 ifICM band is 4-5 then correspond TRU is faulty get replacement (for finding thecorresponding TRU use BPC no. in RLCRP: CELL=cell; and RXCDP: MO=RXOTG-tg$)

    4. check handover report form Network quality report that is handover isproperly work

    5. define handover if not present in neighbor list using the commandRLNRP: CELL=cell, CELLR=all; ( for neighbor list)RLNRI: CELL=cell, CELLR=cellr; (for cellr add in neighbor list)