Direct Mount (NAMUR) Valve Features Electrical characteristics 5/2 Single Solenoid 341Y 5/2 Double Solenoid 342Y 5/3 Double Solenoid 343Y • Pilot operated 4 way valve(Convertible to 3 way) • Direct mounting to pneumatic actuator • Compact spool valve • Standard Push Button Manual Override (Optional Lever-Lock Manual Override) • Long life cycle (1 Million) • Single and double solenoid • Coil availability (Flying lead / 22mm DIN) • Aluminum valve body, 1/4” Pipe size (G, NPT connection) Voltages • DC: 24 • AC: 110/50-120/60, 220/50-240/60 Voltage Tolerance • Plus & Minus 10% Coil Insulation Class • "F": 155 o C(311 o F) Electrical Connections • Leaded, DIN Ambient Temperature • Minus 15 O C ~ Plus 60 O C (5 O F~ 140 O F) Maximum Fluid Temperature • Plus 60 O C (140 O F) Options DIN Connector • PES5: DIN Connector (without lamp) • PES5 L-24V: DIN Connector (with lamp), DC 24V • PES5 L-110V: DIN Connector (with lamp), AC 110V/50Hz, 120V/60Hz • PES5 L-220V: DIN Connector (with lamp), AC 220V/50Hz, 240V/60Hz Conversion plate • CP01: Conversion plate from 4 way to 3 way Pressure Vessel Specifications Pressure vessel Description Cv Operating Pressure Temperature Range Response Time Catalog number Min. Max. Min. Max. (at 5 bar) G1/4 341Y312UNM0 5/2 Single Solenoid 1.6 1.5 bar 10 bar -15 O C 60 O C 30ms or less 342Y312UNM0 5/2 Double Solenoid 1.6 1.0 bar 10 bar -15 O C 60 O C 30ms or less 343Y312SNM0 5/3 Double Solenoid 1.0 2.0 bar 10 bar -15 O C 60 O C 40ms or less 1/4” NPT 341Y332UNM0 5/2 Single Solenoid 1.6 1.5 bar 10 bar -15 O C 60 O C 30ms or less 342Y332UNM0 5/2 Double Solenoid 1.6 1.0 bar 10 bar -15 O C 60 O C 30ms or less 343Y332SNM0 5/3 Double Solenoid 1.0 2.0 bar 10 bar -15 O C 60 O C 40ms or less Note: Above 6 vessels have standard Push Button Manual Override. If you need optional “Lever-Lock” Manual Override, please change the last two digit from “MO” to “ML”. Mechanical characteristics Standard material of construction • Body: Aluminum (Diecasting) • Spool: Aluminum (Diecasting) • Seals: NBR • Springs: Stainless Steel • Sleeve tube: Stainless Steel • Cap: Zinc (Pressure diecasting) Compatible Fluid Lubricated Air, Non-Lubricated Air, Inert Gases and other gases compatible with materials of construction Coil Specifications Coil Description Power Consumption Max Ambient Catalog Number DC AC Temp. Flying lead PEC5-24V Coil (length 500 mm), Class F, DC24V 2.5W - 60 O C (140 O F) PEC5-110V Coil (length 500 mm), Class F, AC 110/50Hz-120/60Hz - 2.5W 60 O C (140 O F) PEC5-220V Coil (length 500 mm), Class F, AC 220/50Hz-240/60Hz - 2.5W 61 O C (140 O F) DIN (Ordinary location) PEC5-D-24V DIN coil, Class F, DC 24V 2.5W - 60 O C (140 O F) PEC5-D-110V DIN coil, Class F, AC 110/50Hz-120/60Hz - 2.5W 60 O C (140 O F) PEC5-D-220V DIN coil, Class F, AC 220/50Hz-240/60Hz - 2.5W 60 O C (140 O F) DIN (Hazardous location, EEx m II T4) PEC5-22EX-24V DIN coil with 3000mm cable, Class F, DC 24V 5.0W - 60 O C (140 O F) PEC5-22EX-110V DIN coil with 3000mm cable, Class F, AC 110-120/50-60Hz - 5.0W 60 O C (140 O F) PEC5-22EX-220V DIN coil with 3000mm cable, Class F, AC 220-240/50-60Hz - 5.0W 60 O C (140 O F) Note: In using DIN coil, you should use DIN connector (see options). All DIN coils are 22mm DIN standard, DIN43650B. All coils are IP65 protection. King Of Valve Co.,Ltd.

Upload: duonglien

Post on 26-Apr-2018

334 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: 5/2 Single Solenoid 341Y 5/2 Double Solenoid 342Y 5/3 ... · 5/2 Double Solenoid 342Y ... FAX : (82) 31 379-2239 Valve Odering Drawing ... 5/2 Single Solenoid + DIN Coil 5/2 Double

Direct MMount ((NAMUR) VValve

Features

Electrical characteristics

5/2 Single Solenoid 341Y

5/2 Double Solenoid 342Y

5/3 Double Solenoid 343Y

• Pilot operated 4 way valve(Convertible to 3 way)

• Direct mounting to pneumatic actuator

• Compact spool valve

• Standard Push Button Manual Override(Optional Lever-Lock Manual Override)

• Long life cycle (1 Million)

• Single and double solenoid

• Coil availability (Flying lead / 22mm DIN)

• Aluminum valve body, 1/4” Pipe size(G, NPT connection)

Voltages• DC: 24• AC: 110/50-120/60, 220/50-240/60Voltage Tolerance• Plus & Minus 10%Coil Insulation Class• "F": 155oC(311oF)Electrical Connections• Leaded, DINAmbient Temperature• Minus 15OC ~ Plus 60OC (5OF~ 140OF)Maximum Fluid Temperature• Plus 60OC (140OF)

OptionsDIN Connector• PES5: DIN Connector (without lamp)

• PES5 L-24V: DIN Connector(with lamp), DC 24V

• PES5 L-110V: DIN Connector (withlamp), AC 110V/50Hz, 120V/60Hz

• PES5 L-220V: DIN Connector (withlamp), AC 220V/50Hz, 240V/60Hz

Conversion plate

• CP01: Conversion plate from 4 wayto 3 way

Pressure Vessel SpecificationsPressure vessel Description Cv Operating Pressure Temperature Range Response TimeCatalog number Min. Max. Min. Max. (at 5 bar)G1/4341Y312UNM0 5/2 Single Solenoid 1.6 1.5 bar 10 bar -15OC 60OC 30ms or less 342Y312UNM0 5/2 Double Solenoid 1.6 1.0 bar 10 bar -15OC 60OC 30ms or less343Y312SNM0 5/3 Double Solenoid 1.0 2.0 bar 10 bar -15OC 60OC 40ms or less1/4” NPT341Y332UNM0 5/2 Single Solenoid 1.6 1.5 bar 10 bar -15OC 60OC 30ms or less 342Y332UNM0 5/2 Double Solenoid 1.6 1.0 bar 10 bar -15OC 60OC 30ms or less343Y332SNM0 5/3 Double Solenoid 1.0 2.0 bar 10 bar -15OC 60OC 40ms or lessNote: Above 6 vessels have standard Push Button Manual Override.

If you need optional “Lever-Lock” Manual Override, please change the last two digit from “MO” to “ML”.

Mechanical characteristicsStandard material of construction• Body: Aluminum (Diecasting)• Spool: Aluminum (Diecasting)• Seals: NBR• Springs: Stainless Steel• Sleeve tube: Stainless Steel• Cap: Zinc (Pressure diecasting)

Compatible Fluid• Lubricated Air, Non-Lubricated Air,

Inert Gases and other gases compatiblewith materials of construction

Coil SpecificationsCoil Description Power Consumption Max AmbientCatalog Number DC AC Temp.Flying leadPEC5-24V Coil (length 500 mm), Class F, DC24V 2.5W - 60OC (140OF)PEC5-110V Coil (length 500 mm), Class F, AC 110/50Hz-120/60Hz - 2.5W 60OC (140OF)PEC5-220V Coil (length 500 mm), Class F, AC 220/50Hz-240/60Hz - 2.5W 61OC (140OF)DIN (Ordinary location)PEC5-D-24V DIN coil, Class F, DC 24V 2.5W - 60OC (140OF)PEC5-D-110V DIN coil, Class F, AC 110/50Hz-120/60Hz - 2.5W 60OC (140OF)PEC5-D-220V DIN coil, Class F, AC 220/50Hz-240/60Hz - 2.5W 60OC (140OF)DIN (Hazardous location, EEx m II T4)PEC5-22EX-24V DIN coil with 3000mm cable, Class F, DC 24V 5.0W - 60OC (140OF)PEC5-22EX-110V DIN coil with 3000mm cable, Class F, AC 110-120/50-60Hz - 5.0W 60OC (140OF)PEC5-22EX-220V DIN coil with 3000mm cable, Class F, AC 220-240/50-60Hz - 5.0W 60OC (140OF)Note: In using DIN coil, you should use DIN connector (see options).

All DIN coils are 22mm DIN standard, DIN43650B. All coils are IP65 protection.

KingOf V

alve C

o.,Ltd

.

Page 2: 5/2 Single Solenoid 341Y 5/2 Double Solenoid 342Y 5/3 ... · 5/2 Double Solenoid 342Y ... FAX : (82) 31 379-2239 Valve Odering Drawing ... 5/2 Single Solenoid + DIN Coil 5/2 Double

Parker Korea Ltd.777, Jung-ri, Dongtan-Myun, Whaseong-City, Gyunggi-Do, 445-813, KoreaPhone : (82) 31 379-2200FAX : (82) 31 379-2239

Valve Odering

Drawing

• Step 1: Select the appropriate pressure vessel

• Step 2: Select the type of manual overrideIf you need optional “Lever-Lock” Manual Override, please change the last two digit from “MO” to “ML”

• Step 3: Select the appropriate coil

• Step 4: If you use DIN coil, you should order DIN connector

Ordering example:- 100 nos of 341Y312UNML- 100 nos of PEC5-D-220V- 100 nos of PES5 L-220V

5/2 Single Solenoid + DIN Coil 5/2 Double Solenoid + DIN Coil

5/3 Double Solenoid + DIN Coil CP01 Conversion Plate

NAMUR Valve