Gas-Liquid separators
Roberto BubbicoPhD, Chem. Eng.Department of Chemical Engineering“Sapienza” University of [email protected]
![Page 2: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/2.jpg)
INTRODUCTION• In phase separation, two or more phases can be
separated because a given force will act differently on them, or because one of the phases impacts on a solid barrier.
• The forces are usually gravity, centrifugal, and electromotive.
• Examples are removal of a solid from a liquid by impaction (filtration), gravity (settling), centrifugal force (cyclones or centrifuges), and the attraction of charged particles in an electrostatic precipitator.
![Page 3: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/3.jpg)
INTRODUCTION• One exception to these mechanisms is
drying by evaporating unbonded water from a solid. In this case, separation of a liquid from a solid occurs by mass transfer.
• Since many component separations require contacting two phases, like liquid-liquid extraction, component separation is frequently followed by phase separation.
• Phase separators can be classified according to the phases in contact: liquid-gas, liquid-liquid, liquid-solid, solid-gas, …
![Page 4: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/4.jpg)
INTRODUCTION• In many cases separators will also have the
role of accumulators, with the aim of reducing fluctuations in flow rate, pressure and/or composition (improving process control)
• Where the carryover of some fine droplets can be tolerated it is often sufficient to rely on gravity settling in a vertical or horizontal separating vessel (K-O drum or knockout pot).
![Page 5: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/5.jpg)
INTRODUCTIONReasons for using gas-liquid or vapor-liquid
separators are:• to recover valuable products,• improve product purity,• reduce emissions,• protect downstream equipment,• ...
Gas-liquid separators are used after flashing a hot liquid across a valve (flash drum)
![Page 6: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/6.jpg)
INTRODUCTION
The forces acting on a liquid droplet suspended in a gas are:
VVpDD UDCF ρπ 22
8=
L
VLB
gMFρρ
=
gMF LG =• gravity (acting downward)
• buoyancy (acting upward)
• drag (acting upward).
![Page 7: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/7.jpg)
INTRODUCTION
From a force balance:
net gravity force = drag force
FG = FD
The relative velocity is given by:
( )VD
VLpT C
gDU
ρρρ
34 −
=
![Page 8: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/8.jpg)
INTRODUCTION• The drag coefficient C’ is a function
of the Reynolds number: µρ pTG DU
=Re
• Depending on the Reynolds number, the terminal velocity can be defined further:
• Re>500 (Newton’s law)
• Re<2 (Stokes’ law)
• 2<Re<500
G
GLpT
gDU
ρρρ )(
74.1−
=
µρρ )(2
GLpT
gDU
−=
43.029.0
71.014.171.0 )(54.3µρ
ρρ
G
GLpT
DgU
−=
![Page 9: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/9.jpg)
INTRODUCTIONAs a matter of fact, the terminal velocity is calculated as:
where K is an empirical constant which depends on• properties of the fluids, • design of the separator, • size of the drops, • vapor velocity, • degree of separation required
( )V
VLT KU
ρρρ −
=
![Page 10: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/10.jpg)
INTRODUCTION
• In general around 95 % separation of liquid from vapor is accomplished by an empty drum
• If greater separation efficiencies are required, or very small drops need to be separated an uneconomically large separator should be used
• Very small drops (down to 1 µm) can be separated by impaction using a wiremesh pad located at the top of the separator
![Page 11: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/11.jpg)
INTRODUCTION
• Entrained liquid drops in the vapor impact on the wires and coalesce until the drops become heavy enough to break away from the wire and fall to the bottom of the separator
• The use a wire-mesh mist eliminator, installed near the vapor outlet allows to get separation efficiencies of about 99.9% or greater
![Page 12: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/12.jpg)
INTRODUCTION
• The mesh usually consists of 0.011 in (0.279 mm) diameter wires interlocked by a knitting machine to form a pad from 4 to 6 in (0.102 to 0.152 m) thick.
• Because of the large free volume of the pad - 97 to 99 % - the pressure drop across the pad is usually less than 1.0 in of water
![Page 13: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/13.jpg)
INTRODUCTION
• The sizing of a separator depends on the value of the empirical constant K (or KD).
• The value of KD is largely influenced by the presence of internals. Normally, the value provided by the internals manufacturer should be assumed
• In the absence of manufacturer data, literature data can be used
![Page 14: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/14.jpg)
INTRODUCTION
![Page 15: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/15.jpg)
INTRODUCTION
• The value of K also depends upon the operating pressure
![Page 16: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/16.jpg)
INTRODUCTION
• For horizontal separators, the separation efficiency depends on the total vapor travel length within the vessel.
![Page 17: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/17.jpg)
INTRODUCTION
• A longer vessel makes it easier to remove liquid droplets.
• The values of K usually reported for a horizontal vessel, refer to a vessel length of 3.05 m.
• A typical design K value for horizontal separators is defined as 56.0
05.3⎟⎠⎞
⎜⎝⎛=
LKKD
![Page 18: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/18.jpg)
INTRODUCTION
• For a two-phase vapor–liquid separator, both vertical and horizontal configurations are used, and the selection should be made on a case-by-case basis
• Vertical separators have the advantage of lower space requirement and easy-to-install control systems, but horizontal drums are typically smaller for high liquid loading service
![Page 19: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/19.jpg)
INTRODUCTION
• In a horizontal separator, with an increase in liquid level, the area of the vapor space is reduced and the possibility of liquid entrainment increases
• In a vertical separator the vapor-flow area remains constant and liquid entrainment is not an issue
![Page 20: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/20.jpg)
INTRODUCTION
• For a relief KO drum, the horizontal separator is popular simply because of the use of split flow. In this design, one inlet nozzle is used at the vessel center with two outlets on either side. This split-flow advantage is available only in horizontal separators
![Page 21: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/21.jpg)
Horizontal separatorsAdvantages:• Separation efficiency higher than for a vertical separator• The only choice for a single inlet and two vapor outlets• Easy to design for three-phase separation• More suitable for handling large liquid volumes
Disadvantages:• It requires a footprint area larger than a vertical one• At high liquid levels, the liquid entrainment rate
progressively increases with the increase in liquid level
![Page 22: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/22.jpg)
Vertical separatorsAdvantages:• The liquid surface area does not change with liquid
height: liquid entrainment is reasonably constant• It requires a smaller footprint area• Easier to install level instruments, alarms, and shutdown
systems• Usually more efficient for high vapor/liquid ratios
Disadvantages:• Not suitable for three-phase separation• Less suitable for high liquid–vapor ratios
![Page 23: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/23.jpg)
Vertical separators design
• The separator diameter must be determined first
• The gas velocitymust be low enough to allow the liquid droplets to settle out
![Page 24: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/24.jpg)
Vertical separators design
• After defining the maximum droplet diameter, the critical gas velocity Uv can be calculated:
• the minimum vessel diameter is given by: v
vv U
QDπ4
=
• Dv=minimum vessel diameter, m• Qv=gas, or vapour volumetric flow-rate, m3/s• Kv= 0.07 m/s if a demister pad is used, and 0.15*0.07 without
a demister pad, m/s
( )V
VLvv KU
ρρρ −
=
![Page 25: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/25.jpg)
Vertical separators design
The height of the vessel is composed of a number of terms:
• droplet settling length: it is the length from the center line of the inlet nozzle to the bottom of the mist eliminator. – 0.75 D or a minimum of 12 in (0.305 m), or
alternatively– a length equal to the diameter or a minimum of 3 ft
(0.914 m)
![Page 26: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/26.jpg)
Vertical separators design
• height from the bottom of the inlet nozzle to liquid surface: it is required to prevent nozzle flooding.
– a minimum of 6 in (0.152 m) from the bottom of the nozzle to the liquid surface or a minimum of 12 in (0.305 m) from the center line of the nozzle to the liquid surface
– 12 in (0.305 m) plus 1/2 of the inlet nozzle outside diameter or 18 in (0.4570 m) minimum
– 0.5 D or 2 ft (0.610 m) minimum.
![Page 27: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/27.jpg)
Vertical separators design
If a mist eliminator is present (demister pad), the following lengths must be added:
• thickness of the mist eliminator (usually 6 in (0.152 m))
• an additional 12 in (0.305 m) above the eliminator to obtain uniform flow distribution across the eliminator (if it is too close to the outlet nozzle, most of the flow will be directed to the center of the eliminator, with reduced efficiency)
![Page 28: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/28.jpg)
Vertical separators design
• the liquid height: an appropriate residence time of the liquid (surge time) is required to dampen variations in the liquid flow rate.– 2 to 5 min– sometimes 10 min is selected.
2)4/( V
SS D
VHπ
=sLs tQV =
![Page 29: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/29.jpg)
Vertical separators design
• there is a minimum liquid height required to prevent a vortex from forming. The design of the separator will have to include a vortex breaker. The minimum liquid level should cover the vortex breaker plus an additional liquid height
– 2 ft (0.61 m) should generally suffice
• The volume of the dished heads is not included in the design procedure
![Page 30: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/30.jpg)
Vertical separators design
Calculation procedure for vertical separators
1. Select Kv based on the vessel configuration2. Calculate the maximum gas velocity, Uv
3. Calculate the cross-sectional area and diameter, A and Dv
4. Round off D in 6 in (0.152 m) increments, starting at 30 in (0.762 m). If D is less than 30 in (0.762 m), use standard pipe.
![Page 31: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/31.jpg)
Vertical separators design
5. Select a liquid-phase surge time, ts6. Calculate the liquid-level height7. Calculate the total separator height. Round off L
in 3 in(0.0762 m) increments, for example, 5.0, 5.25,
5.5, 5.75 ft etc.8. If L/D < 3.0, then recalculate L so that L/D > 3.0
by letting L/D = 3.2. If L/D > 5 use a horizontal separator.
![Page 32: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/32.jpg)
Vertical separators
![Page 33: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/33.jpg)
Horizontal separators design
• Differently from a vertical separator, in the design of a horizontal separator the vessel diameter is not independent of its length.
![Page 34: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/34.jpg)
Horizontal separators design
The vessel diameter and length, and the liquid level, must allow for:
• sufficient vapour residence time for the liquid droplets to settle out, and
• the required liquid hold-up time to be met• avoid liquid re-entrainment from the liquid
surface• allow enough space for the feed distributor
and the mist eliminator
![Page 35: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/35.jpg)
Horizontal separators design
The vapor velocity might be larger than the drop terminal velocity, with the condition that:
with θ= residence time and τdrop= separation time
KV = 0.125 ft/s (0.038 m/s) no mist pad;KV = 0.437 ft/s (0.133 m/s) with demister
dropτθ >
![Page 36: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/36.jpg)
Horizontal separators design
• In other words:
where– UAH= vapor velocity– UV= critical drop velocity– HV= height for vapor flow
V
V
AH UH
UL
≥V
VAH U
HLU ≤
![Page 37: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/37.jpg)
Horizontal separators design
• Since the upward drag of the vapor is practically absent in a horizontal drum, the empirical coefficient K is the same as for vertical vessels but multiplied by a factor of 1.25
• The vapor velocity must be compared with the maximum velocity to avoid entrainment:
1.024)(
⎪⎭
⎪⎬⎫
⎪⎩
⎪⎨⎧
⎥⎦
⎤⎢⎣
⎡ −⎟⎟⎠
⎞⎜⎜⎝
⎛=
L
VL
VV
Le
gUµ
ρρρσ
ρρ
![Page 38: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/38.jpg)
Horizontal separators design• The most economical length to diameter ratio will
depend on the operating pressure• As a general guide the following values can be used
5>35
420-35
30-20
Length/diameter, L/D
Operatingpressure, bar
![Page 39: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/39.jpg)
Horizontal separators design
• For preliminary designs, set the liquid height at half the vessel diameter:
hv = Dv/2 and fv = 0.5
where fv is the fraction of the total cross-sectional area occupied by the vapour
• In general the minimum cross-sectional area for gas flow should be at least 20 %of the total cross-sectional area
![Page 40: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/40.jpg)
Horizontal separators design
• In the presence of a mist eliminator, the main concern is avoiding its flooding because of a rising liquid level
• The distance from the bottom of the mist eliminator to the liquid level should be at least ½ - 2 ft (0.152 - 0.610 m) and should not be below the center of the separator
• A further distance of 12 in (0.3048m) must be allowed above the eliminator (6 in (0.152 m) thick)
![Page 41: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/41.jpg)
Horizontal separators design
• Assuming the liquid level at the center of the separator, the above rules result in a minimum diameter of 5.5 ft (1.68 m)
![Page 42: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/42.jpg)
Horizontal separators designPreliminary calculation procedure (no.1, see
example)1. Select Kv (e.g. 0.07*0.15) 2. Calculate the maximum vapor velocity, UV3. Calculate the cross-sectional area, A, assuming half total area4. Assume a L/D ratio (e.g. 4)5. Calculate D by equating residence time of the vapor and time to settle
out for the liquid.6. Calculate L.7. Select a liquid phase surge time and check for the actual liquid
residence time8. Adjust the vessel diameter and repeat calculations
![Page 43: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/43.jpg)
Horizontal separators design
Calculation procedure for horizontal separators (no.2)
1. Select Kv2. Calculate the maximum vapor velocity, UV3. Calculate the cross-sectional area, A4. Calculate D. Round off D in 6 in (0.152 m)
intervals, starting at 30 in (0.762 m). If D is less then 30 in (0.762), use standard pipe.
![Page 44: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/44.jpg)
Horizontal separators design
5. Select a liquid phase surge time, ts6. Calculate the separator length. Round off
L in 3 in (0.0762 m) intervals (for example, in feet, 5.0, 5.25, 5.5, 5.75 etc.)
7. If L/D < 3.0, then recalculate L so that L/D > 3.0 by setting L/D = 3.2. If L/D > 5.0, then recalculate D so that L/D < 5.0 by setting L/D = 4.8
![Page 45: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/45.jpg)
Horizontal separators designA more accurate calculation procedure (no.3)
1. Calcolo
2. Calcolo
3. Calcolo
(in questo caso K non tiene conto dello snebbiatore)
VVV WQ ρ/=
LLL WQ ρ/=
V
VLT KU
ρρρ −
= TV UU 75,0=
![Page 46: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/46.jpg)
Horizontal separators designA more accurate calculation procedure (no.3)
4. Fisso TH
5. Fisso L/D (con 1.5<L/D<6) e un grado di riempimento: calcolo un diametro di I° tentativo
(corrisponde ad assumere )
LHH QTV =
3/1
)/(6,0)(4
⎥⎦
⎤⎢⎣
⎡=
DLVD H
π
TH VV %60=
![Page 47: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/47.jpg)
Horizontal separators designA more accurate calculation procedure (no.3)
6. La sezione totale:
7. Fisso il livello minimo di liquido HLL (da tabelle) oppure:
HLL = 0.5 D + 7 (D=ft, HLL=in) con un minimo di HLL=9 in per D < 4 ft
4
2DATπ
=
![Page 48: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/48.jpg)
Horizontal separators design
8. Noto HLL/D, calcolo ALL/AT e ALL
in alternativa, con
x= ALL/AT ey= HLL/D :
( ) ( ) 2211 2121cos yyyyx −−−−= −ππ
![Page 49: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/49.jpg)
Horizontal separators design
9. HV=max (0,2D; 1 ft) (senza demister)HV=max (0,2D; 2 ft) (con demister)Da HV/D calcolo AV/AT e quindi AV
10.Calcolo la L richiesta dall’hold-up liquido
LLVT
H
AAAVL
−−=
![Page 50: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/50.jpg)
Horizontal separators design
11.Calcolo il tempo di caduta (‘drop-out time’):
12.Calcolo la velocità del vapore:
V
Vdrop U
H=τ
VVVA AQU /=
![Page 51: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/51.jpg)
Horizontal separators design
13.Verifico che la velocità ottenuta sia minore di quella di trascinamento:
14.Calcolo la lunghezza minima richiesta per l’abbattimento del liquido:
1.024)(
⎪⎭
⎪⎬⎫
⎪⎩
⎪⎨⎧
⎥⎦
⎤⎢⎣
⎡ −⎟⎟⎠
⎞⎜⎜⎝
⎛=
L
VL
VV
Le
gUµ
ρρρσ
ρρ
dropVAUL τ=min
![Page 52: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/52.jpg)
Horizontal separators design
15.– Se L<Lmin (differenza < 20%) =>
pongo L=Lmin (l’abbattimento del vapore è controllante)
– Se L<<Lmin si incrementa HV e si riparte da 9.
– Se L>Lmin => OK– Se L>>Lmin (hold-up controllante) si
può aumentare Lmin e ridurre L diminuendo HV (se maggiore del minimo in 9.)
![Page 53: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/53.jpg)
Horizontal separators design
16.Si verifica L/D.– Se L/D>6 => si aumenta D e si riparte da 6.– Se L/D<1.5 => si riduce D e si riparte
da 6.
17.Si calcola il peso totale del recipiente (costo). Si varia il diametro D facendo variare 1.5<(L/D)<6 e si trova il rapporto ottimale
![Page 54: 50371317 Comparison Horizontal vs Vertical Separator](https://reader035.vdocuments.us/reader035/viewer/2022081716/552db4bd55034614108b47a3/html5/thumbnails/54.jpg)
Horizontal separators design
18.Una volta identificate le dimensioni ottimali si calcolano le altezze effettive:
– ANL=ALL+VH/L
– Da ANL/AT HNL
– e quindi HHL=D-HV.