5 zxun uspp(hlre) bc en commissioning and debugging(basic data configuration) 3 ppt 201008(draft) 74
DESCRIPTION
USPPTRANSCRIPT
USPP_DC001_E1_1ZXUN USPP Basic Data Configuration
Targets
Master Data Configuration Flow Master OMM Access Configuration Master Physical Data Configuration Master UDS Configuration Master Administration Domain Data Configuration Master Data Transfer
Contents
Data Configuration Flow OMM Access Configuration Physical Data Configuration UDS Configuration Administration Domain Data Configuration Data Transfer
ZXUN USPP Configuration Flow
Contents
Data Configuration Flow OMM Access Configuration Physical Data Configuration UDS Configuration Administration Domain Data Configuration Data Transfer
OMM Access Configuration
Flow of OMM Access Configuration1. Loading the License File
2. Creating a USPP
3. Creating a Network Element Agent
4. Starting a Network Element Agent
5. Updating USPP
6. Validating the License
7. Uploading the License to OMM Server
8. Adding a Network Element on OMM
9. Adding a USPP Physical Office
10. Loading the Schema
Loading the License File
1. On the NetnumenTM M31 main window, select menu Views > License Management.
2. On the License tab, select the NetNumen node.
3. On the License Detail Info tabe, click the (Update License Info) button.
4. Select the License file and click Open.
Loading the License File
Creating a USPP
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select the NetNumen node.
3. On the MML commands navigation tree, select USPP CONFIGURATION MANAGEME
NT > USPP NODE CONFIGURATION MANAGEMENT > CREATE USPP (CREATE U
SPP).
Creating a Network Element Agent
1. On the NetnumenTM M31 main window, select menu Views > Topology Management.
2. On the Physical View tab, right-click the NetNumen node and then select Create NE Agent from the pop-up menu.
Creating a Network Element Agent
Starting a Network Element Agent
1. On the NetnumenTM M31 main window, select menu Views > Topology Management.
2. On the Physical View tab, right-click the NE agent under the NetNumen node, and then select NE Agent Management > Start from the pop-up menu.
Updating USPP
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal to ope
n the MML Terminal window.
2. Select the NetNumen node.
3. On the MML commands navigation tree, select USPP CONFIGURATION MANAGEME
NT > USPP SNO MANAGEMENT > SHOW USPP SNO to open the SHOW USPPSNO
command interface.
4. Click the Execute(F5) button or press F5 to query the latest version of the OMM.
5. On the MML commands navigation tree, select USPP CONFIGURATION MANAGEME
NT > USPP SNO MANAGEMENT > UPDATE USPP to open the command interface s
hown in the following figure.
Validating the License
1. On the NetNumen(TM) M31 main window, select menu Views > License Management.
2. On the License tab, select the NetNumen node.
3. On the License Detail Info tab, click the (License Info Enable) button.
Uploading the License to OMM Server
1. On the NetNumen(TM) M31 main window, select menu Views > License Management.
2. On the License tab, select the NetNumen node.
3. On the License Detail Info tab, click the (License Info Synchronization) button.
Adding a Network Element on OMM
1. On the NetNumen(TM) M30 main window, select menu Views > MML Terminal.
2. Select root from the NetNumen navigation tree.
3. On the MML Commands navigation tree, select System Maintenance > Net Element
Configuration > Create Management Configuration (ADD NE).
Adding a USPP Physical Office
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select the NetNumen node.
3. On the MML commands navigation tree, select USPP CONFIGURATION MANAGEME
NT > USPP NE CONFIGURATION MANAGEMENT > ADD USPPNE (ADD USPPNE).
Loading the Schema
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select menu Operation > Batch.
3. Click the (Import File) button to select and import the batch commands file of Schema.
4. Click the (Run Batch) button to execute the commands in batch.
Loading the Schema
5. Perform the following operations to confirm the loading.① Select NetNumen > USPP > Device Configuration > Public Device Configuration.
② On the MML commands navigation tree, select MML Commands > UDS Dev Configuration > Show UDS Dev > Show Schema Version Configuration (SHOW SCHVER).
③ Click the Execute(F5) button or press F5 to execute this command, confirm that the latest version is what has been uploaded.
Contents
Data Configuration Flow OMM Access Configuration Physical Data Configuration UDS Configuration Administration Domain Data Configuration Data Transfer
Physical Data Configuration Flow
Adding a Rack
1. On the NetNumen(TM) M30 main window, select menu Views > MML Terminal.
2. Select the current working office node under root.
3. On the MML commands navigation tree, select MML Commands > Device Configurat
ion > Physical Configuration > Rack Configuration > Create Rack (ADD RACK).
Adding a Shelf
1. On the NetNumen(TM) M30 main window, select menu Views > MML Terminal.
2. Select the current working office node under root.
3. On the MML commands navigation tree, select MML Commands > Device Configurat
ion > Physical Configuration > Shelf Configuration > Create SHELF (ADD SHELF)
to open the window shown in the following figure.
Adding a Unit
The sequence to create units and modules is as follows.1. Add the UIMC unit.
2. Add modules other than OMP and RPU.
3. Add units other than UIMC.
Adding a Unit
1. On the NetNumen(TM) M30 main window, select menu Views > MML Terminal.
2. Select the current working office node under root.
3. On the MML commands navigation tree, select MML Commands > Device Configuration > Physical Configuration > Unit Configuration > Create Unit (ADD UNIT).
Adding a Module
1. On the NetNumen(TM) M30 main window, select menu Views > MML Terminal.
2. Select the current working office node under root.
3. On the MML commands navigation tree, select MML Commands > Device Configurat
ion > Physical Configuration > Module Configuration > Create Module (ADD MOD
ULE).
Configuring TCP Transfer for TIPI
1. On the NetNumen(TM) M30 main window, select menu Views > MML Terminal.
2. Select the current working office node under root.
3. On the MML commands navigation tree, select MML Commands > Device Configurat
ion > Physical Configuration > TCP Transmit Configuration > Create TCP Transmi
t (ADD TCPTRANS).
Setting the IP of the OMP module
1. On the NetNumen(TM) M30 main window, select menu Views > MML Terminal.
2. Select the current working office node under root.
3. On the MML commands navigation tree, select MML Commands > Device Conf
iguration > Global Data Configuration > Modify Global Data OMP Informatio
n (SET OMP).
Adding a Service Server Node
1. On the NetNumen(TM)M30 main window, select menu Views > MML Terminal.
2. Select the current working office node under root.
3. On the MML commands navigation tree, select MML Commands > Device
Configuration > Server Node Configuration > Back Server > Create Back Server
(ADD BACKSVR).
Setting the Connection Between a Service Server Node and the OMM
1. On the NetNumen(TM)M30 main window, select menu Views > MML Terminal.
2. Select the current working office node under root.
3. On the MML commands navigation tree, select MML Commands > Device
Configuration > Server Node Configuration > Back Server Node Configuration >
Create Back Server Node Configuration (ADD HSERV).
Contents
Data Configuration Flow OMM Access Configuration Physical Data Configuration UDS Configuration Administration Domain Data Configuration Data Transfer
UDS Configuration Flow
Adding a Database Node1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration. (USPP here is a USPP node created by the CREATE USPP command).
3. On the MML commands tree, select MML Commands > UDS Dev Configuration > Database Node Configuration > Create Database Node Configuration (ADD DBNODE).
Adding a DSA Node
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.
3. On the MML commands navigation tree, select MML Commands > UDS Dev Configuration > DSA Node Configuration > DSA Node Configuration > Create DSA Node Configuration (ADD DSANODE).
Setting DSA Node Options
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.
3. On the MML commands tree, select MML Commands > UDS Dev Configuration > DSA Node Configuration > DSA Node Option Configuration (SET DSANODEOPT).
Setting DSA Node Storage Configuration
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal to open the MML Terminal window.
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.
3. On the MML commands tree, select MML Commands > UDS Dev Configuration > DSA Node Configuration > DSA Node Storage Configuration > Create DSA Node Storage Configuration (ADD DSANODESAV).
Adding a DSA
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.
3. On the MML commands navigation tree, select MML Commands > UDS Dev Configuration > DSA Configuration > DSA Configuration > Create DSA Configuration (ADD DSA).
Adding a DSA Member
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.
3. On the MML commands navigation tree, select MML Commands > UDS Dev Configuration > DSA Configuration > DSA Member Configuration > Create DSA Member Configuration (ADD DSACLU).
Setting DSA Options
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.
3. On the MML commands navigation tree, select MML Commands > UDS Dev Configuration > DSA Configuration > DSA Option Configuration > Modify DSA Option Configuration (SET DSAOPT).
Adding Subscriber Table Capacity
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.
3. On the MML commands tree, select MML Commands > UDS Dev Configuration > DSA Configuration > DSA Subscriber Capacity Configuration > Create DSA Subscriber Capacity Configuration (ADD CAPSUB).
Adding an ID DSA Group
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal to open the MML Terminal window.
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.
3. On the MML commands tree, select MML Commands > UDS Dev Configuration > DSA Group Configuration > IDSA Group Configuration > Create IDSA Group Configuration (ADD IDDSAGRP).
Distributing Numbers to an ID DSA
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.
3. On the MML commands tree, select MML Commands > UDS Dev Configuration > DSA Group Configuration > IDSA Distributing Configuration > Create IDSA Distributing Configuration (ADD IDSAMAP).
Adding a P DSA Group
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.
3. On the MML commands tree, select MML Commands > UDS Dev Configuration > DSA Group Configuration > PDSA Group Configuration > Create PDSA Group Configuration (ADD DSAGRP).
Setting UDS Load Control
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.
3. On the MML commands tree, select MML Commands > UDS Dev Configuration > Load Control Configuration > Modify Load Control Configuration (SET LOADLEV).
Setting UDS Parameters
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.
3. On the MML commands tree, select MML Commands > UDS Dev Configuration > UDS Parameter Configuration > UDS Parameter Configuration > Modify UDS Parameter Configuration (SET UDSPARA).
Setting UDS Parameters
Setting the Capacity of a Configuration Table
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.
3. On the MML commands tree, select MML Commands > UDS Dev Configuration > UDS Parameter Configuration > CM Table Capacity Configuration > Modify CM Table Capacity Configuration (SET CAPCFG).
Setting the Capacity Scale of a Subscriber Data Table
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.3. On the MML commands tree, select MML Commands > UDS Dev Configuration > UD
S Parameter Configuration > Subscriber Table Capacity Scale Configuration > Modify Subscriber Table Capacity Scale Configuration (SET CAPSUBSCL).
Adding a DUA Node
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.
3. On the MML commands tree, select MML Commands > FE/Provision Configuration > Create FE/Provision Configuration (ADD DUANODE).
Adding a Monitoring Center
1. On the NetNumen(TM) M31 main window, select menu Views > MML Terminal.2. Select NetNumen > USPP > Device Configuration > Public Device Configuration.3. On the MML commands tree, select MML Commands > CC Resource Configuration
> Create CC Resource Configuration (ADD DMCC).
Contents
Data Configuration Flow OMM Access Configuration Physical Data Configuration UDS Configuration Administration Domain Data Configuration Data Transfer
Administration Domain Data Configuration
The Flow of Administration Domain Configuration
Adding an Administration Domain
1. On the Netnumen(TM) M31 main window, select menu Views > MML Termin
al.
2. Select NetNumen > USPP > Service Configuration > Public Service Confi
guration.
3. On the MML commands navigation tree, select MML Commands> dminDom
ain Basic Configuration > AdminDomain Configuration > Create AdminD
omain Configuration( ADD VHLR).
Adding an Administration Domain
Configuring Relation Between Administration Domain and DUA
1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.
3. On the MML commands navigation tree, select MML Commands > AdminDomain Ba
sic Configuration > AdminDomain Relating DUA Configuration > Create AdminD
omain Relating DUA Configuration(ADD VDUA).
Adding Administration Domain Function
1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.
3. On the MML commands navigation tree, select MML Commands > AdminDomain Ba
sic Configuration > AdminDomain Function Switch Configuration > Create Admi
nDomain Function Switch Configuration(ADD VHLRLIC).
Adding Administration Domain Capacity
1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.
3. On the MML commands navigation tree, select MML Commands > AdminDomain Bsic Configuration > AdminDomain Capacity Configuration > Create AdminDomain Capacity Configuration(ADD VHLRCAP).
Configuring Relation Between PDSA Group and Administration Domain1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.
3. On the MML commands navigation tree, select MML Commands > Subscriber Data Distributing Configuration > PDSA Group–AdminDomain Relation Configuration > Create PDSA Group–AdminDomain Relation Configuration (ADD VDSAGRP).
Adding a Physical Number Segment for an Administration Domain 1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.
3. On the MML commands navigation tree, select MML Commands > Subscriber Data Distributing Configuration > AdminDomain Physics Number Distributing Configuration > Create AdminDomain Physics Number Distributing Configuration (ADD VHLRSPN).
Adding a Logical Number Segment for an Administration Domain1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.
3. On the MML commands navigation tree, select MML Commands > Subscriber Data Distributing Configuration > AdminDomain Logical Number Distributing Configuration > Create AdminDomain Logical Number Distributing Configuration (ADD VHLRSLN).
Distributing a Physical Number Segment to an ID DSA Group 1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.
3. On the MML commands navigation tree, select MML Commands > Subscriber Data Distributing Configuration > IDSA Group Physics Number Distributing Configuration > Create IDSA Group Physics Number Distributing Configuration (ADD IDSAGSPN).
Distributing a Logical Number Segment to an ID DSA Group1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.
3. On the MML commands navigation tree, select MML Commands > Subscriber Data Distributing Configuration > IDSA Group Logical Number Distributing Configuration > Create IDSA Group Logical Number Distributing Configuration (ADD IDSAGSLN).
Distributing a Physical Number Segment to a P DSA Group1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.
3. On the MML commands navigation tree, select MML Commands > Subscriber Data Distributing Configuration > PDSA Group Logical Number Distributing Configuration > Create PDSA Group Logical Number Distributing Configuration (ADD DSAGRPSPN).
Adding an Agent Number Segment Group
1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.
3. On the MML Commands navigation tree, select Agent Resource Configuration > Agent Number Group Configuration > Create Agent Number Group Configuration(ADD NUMGRP).
Adding an Agent Physical Number Segment
1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.
3. On the MML Commands navigation tree, select Agent Resource Configuration > Agent Physical Number Segment Configuration > Create Agent Physical Number Segment Configuration(ADD AGENTSPN).
Adding an Agent Logical Number Segment
1. On the Netnumen(TM) M31 main window, select menu Views > MML Terminal.
2. Select NetNumen > USPP > Service Configuration > Public Service Configuration.
3. On the MML Commands navigation tree, select Agent Resource Configuration > Agent Logical Number Segment Configuration > Create Agent Logical Number Segment Configuration(ADD AGENTSLN).
Adding an Operator Role
1. On the Netnumen(TM) M31 main window, select menu Views > Security Management.
2. Select Role Management from the Security Tree.
3. Click the (Create Role) button to open the Create Role dialog box.
4. On the Basic Information tab, Set Role Name and Role Description.
5. On the Access Rights tab, set rights.
Adding an Operator Role
Adding an Operator
1. On the Netnumen(TM) M31 main window, select menu Views > Security Management.
2. Select User Management from the Security Tree.
3. Click the (Create User) button.
Adding an Operator
Contents
Data Configuration Flow OMM Access Configuration Physical Data Configuration UDS Configuration Administration Domain Data Configuration Data Transfer
Uploading OMM Configuration Data
1. On the NetNumen(TM)M30 HLR main window, select menu Views > MML Terminal.
2. Select the current working office node under root.
3. On the MML commands navigation tree, select MML Commands > Data
Maintenance > Data Transfer > Sync Data (Only Used By Admin) (SYNA).
Uploading EMS Configuration Data
1. On the Netnumen(TM) M31 main window, select menu Views > Daily Maintenance.
2. Select Daily Maintenance > USPP > Data Maintenance > Data Sync from the navigation tree.