4vshj7fu$potvnbcmft$bubmphvfsoundvet.com.au/wp-content/uploads/2015/04/sve... · et24 rill rk24...

36
SOUND VETERINARY EQUIPMENT • P: 1300 881 681 • F: 1300 881 682 3 Issue: SC05/14 CRITICAL CARE CONSUMABLES 2014 SurgiVet Consumables Catalogue

Upload: others

Post on 25-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SOUND VETERINARY EQUIPMENT • P: 1300 881 681 • F: 1300 881 682 3

Issue: SC05/14

CRIT

ICA

L CA

RE C

ON

SUM

ABL

ES

2014 SurgiVet Consumables Catalogue

Page 2: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES2

TABLE OF CONTENTS

Airway Management 3

Gastroenterology 8

Fluid Administration & Therapy 12

Needles 14

Reproduction 15

Urology 16

Central Venous Catheters 20

Wound Management 22

Consumable Product Accessories 28

Product Index 32

Products marked with this symbol are reusable and autoclavable

Large Animal Cuffed Endotracheal Tubes, Page 5

ClearView Oral/Nasal Oxygen/Feeding Tubes, Page 9

Subcutaneous Catheter Set, Page 13

Slippery Sam Tomcat Catheters, Page 16

Economy ClearView & Premium Foley Catheters, Page 18-19

Thoracic Drainage Catheters, Page 23

Page 3: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 3

Non-Cuffed Endotracheal Tubes (Silicone)

Non-cuffed endotracheal tubes are typically used for birds, reptiles, amphibians, marsupials, neonates and very small animals.Features:• Non-sterile• Radiopaque• Parallel wall design• Silicone• Reusable and autoclavable• Wire guide stylet supplied

Code Tube I.D. (mm) Length (cm)AT10 1.0 12

AT15 1.5 12

Non-Cuffed Endotracheal Tubes (Silicone)

Non-cuffed endotracheal tubes are typically used for birds, reptiles, amphibians, marsupials, neonates and very small animals.

Features:• Non-sterile• Lowerprofiledistalportionofthetubeassistsplacement.• Larger proximal tube portion forms a seal against the vocal cords to reduce

anaesthesia gas loss.• Stepped wall design (Cole-Style Tube)• Reusable and autoclavable• Radiopaque

Code Tube I.D. (mm) Tube O.D. at Shoulder (mm)

French Size Length (cm)

AT20 2.0 5.0 9 13

AT25 2.5 6.3 12 13

AT30 3.0 8.0 13.6 15

AT35 3.5 8.6 16 15

AT40 4.0 9.6 18.3 15

AT50 5.0 12.6 23.6 18

AIRWAY MANAGEMENT

Page 4: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES4

Non-Cuffed Wire Reinforced Endotracheal Tubes (Silicone)

Features:• Non-sterile and transparent• Radiopaque marker in distal tip• Reusable and autoclavable• Recommended to be used with malleable stylets.

Code Tube I.D. (mm) Tube O.D. (mm) French Size Length (cm)ATR25 2.5 4.0 12 14

ATR30 3.0 4.7 14 16

ATR35 3.5 5.3 16 18

ATR40 4.0 6.0 18 20

ATR45 4.5 6.7 20 22

ATR50 5.0 7.3 22 24

Cuffed Wire Reinforced Endotracheal Tubes (Silicone)

Features:• Non-sterile• Radiopaque marker in distal tip• Reusable and autoclavable• 15mm connector

Code Tube I.D. (mm) Tube O.D. (mm) French Size Length (cm)V35W30 3.0 4.7 14 16

V35W40 4.0 6.0 18 20

V35W50 5.0 7.3 22 24

JET-100 6.0 8.7 26 28

JET-110 7.0 10.0 30 30

JET-120 8.0 11.3 34 32

JET-130 9.0 12.7 38 34

JET-140 10.0 14.0 42 36

AIRWAY MANAGEMENT

Endotracheal Tube Stylet with Stopper

Features:• Stainless steel endotracheal tube stylet with silicone stopper• Non-sterile• Autoclavable• Malleable

Code Fits (mm)VSTYLSM 2.5 - 5.5

VSTYLLG 5.5 - 9.5

Page 5: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 5

Cuffed Endotracheal Tubes (Silicone)

Thetubeispositionedwithinthetracheabyoralintubation.Thecuffisinflatedtopreventthe leakage of anaesthetic gas around the tube. The smaller sizes will often require a malleable stylet (VSTYLSM or VSTYLLG) to aid in introduction.

Features:• Non-sterile and transparent• Reusable and autoclavable• Radiopaque• Tubesupto12mmhavea15mmairwayadaptorfitting.• A funnel type silicone adaptor is supplied with 14mm and 16mm tubes as well as a

15mm adaptor.• Tubes 18mm upwards are only supplied with the funnel adaptor.• Repaircuffsandinflationlinesavailable.

Code Tube I.D. (mm)

Tube O.D. (mm)

French Size

Length (cm)

Balloon Length (cm)

ET2 2 3.7 10 16 2

ET3 3 4.7 14 16 2

ET4 4 6.0 18 18 2

ET5 5 7.3 22 20 3

ET6 6 8.7 26 28 4

ET7 7 10.0 30 30 5

ET8 8 11.0 33 32 5

ET9 9 12.4 37 34 5

ET10 10 14.3 43 36 5

ET11 11 15.7 47 40 5

ET12 12 17.0 51 40 5

ET14 14 19.0 57 57 6

ET16 16 22.0 66 70 7.5

ET18 18 24.0 72 75 7.5

ET20 20 26.5 79 90 9

ET22 22 30.0 90 90 9

ET24 24 32.0 96 90 9

ET26 26 35.0 105 100 10

ET30 30 42.0 126 100 10

AIRWAY MANAGEMENT

Page 6: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES6

Endotracheal Tube Connectors

Features:• Manufactured to exact tolerances to ensure a safe, secure and leak-resistant

connection.• Tubeconnectorsaredesignedtofitthe54mm(2”)O.D.largeanimalypiece

with Bivona insert.

Code Tube I.D. (mm)

Code Tube I.D. (mm)

Code Tube I.D. (mm)

32121B3 14 32121B5 20 32121B8 26

32121B4 16 32121B6 22 32121B9 30

32121B12 18 32121B7 24 32121B10 35

Large Animal Endotracheal Tube Funnel Adaptor (Silicone)

Features:• Replacement Large Animal Endotracheal Tube Funnel Adaptor

Code Tubes (mm)32364B1 14, 16, 18, 20, 22, 24, 26, 30

Endotracheal Tube Replacement Accessories (Silicone)

Features:• Autoclavable - Non-sterile

Code Inflation Lines Repair Cuff Airway Adaptor AdhesiveET2 RILS RK2 ETCO2 ADH2

ET3 RILS RK3 ETCO3 ADH2

ET4 RILS RK4 ETCO4 ADH2

ET5 RILS RK5 ETCO5 ADH2

ET6 RILS RK6 ETCO6 ADH2

ET7 RILS RK7 ETCO7 ADH2

ET8 RILS RK8 ETCO8 ADH2

ET9 RILS RK9 ETCO9 ADH2

ET10 RILS RK10 ETC10 ADH2

ET11 RILS RK11 ETC11 ADH2

ET12 RILS RK12 ETC12 ADH2

ET14 RILS RK14 32121B3 ADH2

ET16 RILL RK16 32121B4 ADH2

ET18 RILL RK18 32121B12 ADH2

ET20 RILL RK20 32121B5 ADH2

ET22 RILL RK22 32121B6 ADH2

ET24 RILL RK24 32121B7 ADH2

ET26 RILL RK26 32121B8 ADH2

ET30 RILL RK30 32121B9 ADH2

AIRWAY MANAGEMENT

Page 7: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 7

Foal Nasal/Porcine Endotracheal Tubes (Silicone)

Features:• Non-sterile• Reusable and autoclavable• Tubesupto12mmhavea15mmairwayadaptorfitting.• A silicone funnel is supplied on the 14mm tube size.• Repairballooncuffsandinflationlinesareavailable.• Radiopaque

Code Tube I.D. (mm) Tube O.D. (mm) Length (cm)FN7 7 10 55

FN8 8 11 55

FN9 9 12.3 55

FN10 10 14.3 55

FN11 11 15.7 55

FN12 12 17 55

FN14 14 19 55

Equine Post Anaesthetic Nasal Tubes (Silicone)

Features:• Non-sterile• Reusable and autoclavable• Aproximalsiliconefunnelfittingtoavoidtubemigration.• Cuffed• Radiopaque

Code Tube I.D. (mm) Tube O.D. (mm) Length (cm)ENAT14 14 19 40

Tracheostomy Tubes (Silicone)

Features:• Sterile• Reusable and autoclavable• Pre-curvedsiliconeforacomfortableanatomicalfit.• For long term or permanent tracheostomy• Cuffed• Radiopaque

Code Tube I.D. (mm) Length (cm)V60050 5 6

V60060 6 7

V60070 7 8

V60080 8 8.8

V60090 9 9.8

AIRWAY MANAGEMENT

Page 8: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES8

OESOPHAGEAL TUBES

Oesophagostomy Tubes are catheters that are introduced into the oesophagus via a percutaneous puncture in the side of the neck for enteral feeding. Nasogastric tubes are commonly used for enteral feeding, but the size of the animal’s nostrils limits the size of the tube that can be used. Commercial liquid diets can go down the smaller diameter tubes, but larger tubes such as the oesophagostomy tubes allow the use of less expensive solutions which are thicker in form.

Feline Oesophagostomy Tubes

Features:• Sterile• Reusable and autoclavable• A surgically placed closed-end single lumen silicone catheter with distal

side holes for the administration of enteral feeding solutions.• Removableproximalfittingacceptsstandardluerlocksyringes.• Radiopaque

Code French Size Length (cm) Proximal FittingFET1423 14 23 Removable

FET1938 19 38 Removable

Each Catheter Includes:1 PFLLA Female Luer Lock Tapered Adaptor1 LLP100 Luer Lock Plug

Oesophagostomy Tube Sets

Features:• An open-end silicone catheter with multiple side holes used for the administration

of enteral feeding solutions.• Catheter introduced after percutaneous puncture of the upper oesophagus with the

supplied Peel-off sheath.• Accurate positioning of the Peel-off sheath needle is aided with use of the

introduction tube.• Sterile• High quality, non-irritating silicone.• Suppliedwithcatheterandfivesheaths.

Code DescriptionOTCS12 12FR Silicone Catheter 60cm long with 8ga, 7cm long Peel-off Sheath Needles (5)

OTCS14 14FR Silicone Catheter 60cm long with 7ga, 7cm long Peel-off Sheath Needles (5)

Code Replacement PartsOTC1260 Silicone Oesophagostomy Catheter, 12FR, 60cm long

OTC1460 Silicone Oesophagostomy Catheter, 14FR, 60cm long

NPOS875 5 Peel-off Sheath Needles 8ga 7cm, 1 needle

NPOS775 5 Peel-off Sheath Needles 7ga 7cm, 1 needle

GASTROENTEROLOGY

Page 9: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 9

ORAL/NASAL OXYGEN FEEDING TUBES

These tubes can be introduced nasally or orally to allow administration of enteral feeding solutions into the stomach or the proximal area of the lower oesophagus. These tubes can also be utilised as nasal lines to provide supplemental oxygen by placing the tip into the nasopharyngeal space.

Economy Clearview Oral/Nasal Oxygen/Feeding Tubes

Features:• Non-sterile• Reusable and autoclavable• A closed-end, single lumen silicone catheter used for the administration of feeding

solutions.• Recommended to be used with PTFE Coated Wire Guides• Integralcaponlightweightproximalfitting(noneedforadaptorsorluerlockplugs)• Clearview allows visualisation of feeding solutions or any occlusions.• Radiopaque• Atraumatic

Code French Size

Length (cm)

Code French Size

Length (cm)

CFT3520 3.5 20 CFT855 8 55

CFT520 5 20 CFT875 8 75

CFT535 5 35 CFT8120 8 120

CFT635 6 35 CFT1040 10 40

CFT655 6 55 CFT1055 10 55

CFT830 8 30 CFT10150 10 150

GASTROENTEROLOGY

ClearView PTFE Coated Wire Guide

Features:• Recommended to be used with Economy Clearview Oral/Nasal Oxygen/Feeding

Tubes and Clearview Foley Catheters. • Sterile• Autoclavable

Code Outer Diameter (in)

Length (cm)

For use with CFC Catheters &

Feeding TubesTCGW2170 0.021” 70 5 Fr & 6 Fr

TCGW3570 0.035” 70 8 Fr

TCGW3870 0.038” 70 10 Fr

TCGW38180 0.038” 180 10 Fr

Page 10: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES10

STOMACH TUBES

Gastrostomy Tube Introduction Set

Features:• Reusable introduction set that enables the non-endoscopic placement of gastrostomy

tubes into the stomach.• Designed to accept either 16 or 20 Fr Peg Feeding Tubes.• Autoclavable, supplied sterile.• GTIS1000 is recommended for use with animals up to 10kg.• GTIS2000 is recommended for use with animals over 10kg.• Contact us for details on use.

GTIS1000 Includes:GTI070TW Stainless Steel Threaded Wire 1mm O.D. 70cm

GTI545IT Introduction Tube 5mm O.D. 45cm

GTI75FA Catheter Fixation Adaptor, Tapered

GTIN1050 Percutaneous Needle 10ga 7cm

GTIS2000 Includes:GTI070TW Stainless Steel Threaded Wire 1mm O.D. 70cm

GTI9585IT Introduction Tube 9.5mm O.D. 85cm

GTI75FA Catheter Fixation Adaptor, Tapered

GTIN1050 Percutaneous Needle 10ga 7cm

Peg Feeding Tubes

Features:• A mushroom/Pezzar style silicone catheter for the percutaneous administration of

feeding solutions into the stomach.

• Can be endoscopically guided or used with a non-endoscopic introduction technique.• The mushroom shaped distal tip assists in retention of the catheter in the stomach.• Catheter markings at 2cm and 4cm from the base of the mushroom tip assist in

correct catheter placement.• The Peg Tube is more secure and can be left in place for a much longer length of

time than any other alternatives.• Silicone• Radiopaque• Reusable and autoclavable• Sterile

Code French Size Length (cm) Mushroom Tip Diameter (mm)

PT16 16 39 15

PT16XL 16 39 20

PT20 20 39 20

PT20XL 20 39 25

PT24XL 24 39 30

GASTROENTEROLOGY

Page 11: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 11

Features:• A closed ended single lumen silicone catheter with distal side holes used for the

administration of enteral feeding solutions. • Proximalfittingacceptsataperedsyringeadaptor.• Reusable and autoclavable• Radiopaque.• Non-sterile

Feline Orogastric Feeding Tube

Code French Size Length (cm)FOT1843 18 43

Fixation Disc (Sterile)

Features:• Siliconefixationdisc• Used to stabilise percutaneous drainage catheters.• Sterile

Code DescriptionFD100 Silicone Fixation Disc

GASTROENTEROLOGY

Page 12: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES12

Connecting Tubes

Features:• Connecting tubes can be used in a variety of ways such as connecting urinary

catheters to collection bags, drainage tubes to suction, nasal lines to oxygen and infusion of liquids into venous circulation.

• Sterile

Code DescriptionCT95250 Flexible Spiral Connecting tube Set 9.5Fr, uncoiled length 250cm. Rotating

adaptor is designed to prevent tangling of lines during infusion therapy.

CT9530 Connecting tube with male Luer and female port 9.5Fr 30cm

CTU14030 ConnectingtubewithmaleLuerandfemaleport(accepts3/4”hosebarb),14Fr, 30cm *Commonly used with Heimlich One-Way Valve (HV100)

Bag to Bag Connectors

Features:• Adoublespikedconnectinglinethatallowstheadditionofasecondfluidbagtoan

existingfluidbag,whengreatervolumesoffluidarerequiredandchangingthebagis not possible. This may occur in a practice overnight where an animal may be onIVfluids,butthereisnostafftheretoswitchovertoanewbag.Oneendofthespikedconnectingtubeisinsertedintothebottomofthefirstfluidbagandthentheother end of the spiked connecting tube is inserted into the front standard puncture areaofthesecondfluidbag.Thesecondbagshouldbehungslightlyhigherthanthefirstbagandtheclampshouldbeleftopensothatthefluidwouldflowfreelyfromthesecondbagtothefirstbagwhenrequired.

• Sterile, Polyvinyl

Code DescriptionLACTEC3 Double-ended spiked connecting tube, 24Fr (8mm O.D.), 40cm long with

two non-vented spikes and G Clamp

Wide Bore Infusion Set (No Chamber)

Features:• Singlespike,wideboresetforrapidfluidadministrationwithmaleluerlockconnector.• Sterile

Code DescriptionLACTEC1 Single, wide bore tubing with spike, 24Fr (8mm O.D.), 200cm length tubing

with rotating cuff male Luer lock

FLUID ADMINISTRATION & THERAPY

Page 13: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 13

Spiked Wide Bore Infusion Sets

Features:• Completespikedwideboretubingsetstoaidindeliveryoffluidstolargeranimals

eg. horses.• Coiled tubing to prevent kinking or twisting of line.• Sterile, polyvinyl

Code DescriptionLACTEC2 Single, wide bore tubing with connector spike, 24Fr (8mm O.D), 450cm

total tubing length, large in-line chamber, roller clamp, injection port and rotating cuff male Luer lock

LACTEC4 Double, wide bore tubing with connector spike, 24Fr (8mm O.D.), 450cm total tubing length, large in-line chamber, roller clamp, injection port and rotating cuff male Luer lock

Subcutaneous Catheter Sets

Features:• Thiscathetersetisusedinpatientsthatneedfrequentfluidtherapyor

subcutaneous medication administration. It is placed under the skin typically lateral to the spine and in between the scapulas of both cats and dogs. When used, this reduces the amount of repeated pokes with a needle that the patient has to endure. Patients can be sent home with the catheter, making it easier for ownerstoadministerfluidsandmedicationstotheirpetwithouthavingtouseneedles.Thisalsoeliminatesrepeatedvisitstothevet’sofficeforsupplementalfluidsforthesetypesofpatients.Canbeusedforupto1year.Theshortstyletreinforces the catheter when not in use and cap prevents contamination.

• Sterile

Code French Size Length (cm)FSQ712 7 12

FSQ718 7 18

FSQ725 7 25

FLUID ADMINISTRATION & THERAPY

Page 14: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES14

Vet-Core™ Biopsy Needles

Features:• The Vet-Core™ Biopsy Needle is a device that provides a one-handed technique

for obtaining a biopsy of organs such as the liver, kidneys, lung or tissue of a tumor. It may be used under direct visual control during operation, by blind insertion into an organ being palpated, by digitally stabilising a kidney through a small incision, or under ultrasound guidance.

• Etched tip enhances visualisation during ultrasound imaging.• Precise,rapidfiringspringmechanismprovidesintactcoretissuesample.• Bevelled point stylet allows easy penetration into specimen with less trauma to

surrounding tissue.• 20mm specimen notch.• Sterile

Code Gauge Length (cm)VC1409 14 9

VC1415 14 15

VC1609 16 9

VC1615 16 15

VC1809 18 9

Needles with Peel-Off Sheaths

Features:• The use of Needles with Peel-off sheaths promote easy and accurate placement of

catheters such as oesophagostomy tubes and central venous catheters. An alternate description would be that the Needles with Peel-off sheaths allow for an easy conduit into the vessel for guiding and placement of the catheter.

• PTFE Peel-off Sheaths• Radiopaque needle and sheath• Sterile

Code Gauge Sheaths NeedleNPOS775 7 5 1

NPOS875 8 5 1

NPOS1055 10 5 1

NPOS1570 15 5 1

NPOS1770 17 5 1

Equine Sacral Joint Needle

Features:• Needle used for injection or aspiration of the sacral joint.• The inner stylet matches the bevel tip of the outer needle.• Sterile• Echogenic tip on outer cannula

Code Gauge Length (cm)ESJN1525 15 25

NEEDLES

Page 15: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 15

Equine Uterine Flushing Catheter

Features:• TheEquineUterineFlushingCatheterisusedforflushingandirrigation,

administration of medications, embryo collection and transfer.• Silicone tube is reusable and autoclavable.• Clamp provided to control delivery.• Sterile

Code Tube I.D. (mm)

Tube O.D. (mm)

French Size Length (cm)

VEUF15 8 12 36 150

VEUF80 8 12 36 80

Equine Fluid Delivery System

Features:• The Equine Fluid Delivery System is commonly used with the Equine Uterine Flushing

Catheter.Itcanalsobeusedinmanyotherapplicationsforanytypeoffluiddelivery.• Silicone tube is reusable and autoclavable.• 5’3”Siliconetubeincludesshutoffclampandbellshapedbottleadaptorwith

medication port/vent.• Sterile

Code Tube I.D. (mm)

Tube O.D. (mm)

French Size Length (cm)

VEFD16 8 13 39 160

REPRODUCTION

Page 16: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES16

Slippery Sam™ Tomcat Urethral Catheters

Features:• ThisPTFE(polytetrafluorethylene)coatedcatheterisusedtoeliminatetheurethral

obstructionandallowdrainageoradministrationoffluids.PolytetrafluoroethyleneisasyntheticfluoropolymerthatisbetterknownbythetradenameTeflon®.ThesignificanceofthePTFEisthatitmakesthecatheterlubricious,makingiteasiertoinsert into the urethra. This catheter is to be used short or medium term only, until a regular tomcat urethral catheter can be placed if necessary.

• Rigid and slippery for easy, atraumatic placement. No stylet required. • Endholeordistalsideholesfordrainageoradministrationoffluids.• Lowprofilesiliconehubwithsutureholeswillaidinpreventingcatheterbeing

removed prematurely by the cat. • The hub will accept a standard luer lock syringe, an IV bag for closed collection or a

Little Herbert™.• Sterile

Code French Size Length(cm)

Side Holes

Endhole Design

TTM3011OE 3.0 11 None Open

TTM3511OE 3.5 11 None Open

TTM3514OE 3.5 14 None Open

TTM3518OE 3.5 18 None Open

TTM3511 3.5 11 Yes Closed

TTM3514 3.5 14 Yes Closed

*TTM3011OE is commonly used in ferrets

Tomcat Urethral Catheters (Silicone)

Features:• This silicone catheter can be used for long term or upon removal of the Slippery

Sam™Catheter.Itallowsdrainageoradministrationoffluids.Thesiliconeallowsit to be left in long term because there is minimal irritation to the urethral mucosa or bladder wall. It is available in closed or open end hole design. The open ended design is most commonly used if there are any stones or paste present in the bladder.

• A wire guide stylet to aid in introduction is also provided with the catheter because of the softness of the silicone.

• Lowprofilesiliconehubwithsutureholeswillaidinpreventingthecatheterbeingremoved prematurely by the cat.

• The hub will accept a standard luer lock syringe, an IV bag for closed collection or a Little Herbert™.

• Reusable & Autoclavable• Sterile.

Code French Size Length(cm)

Side Holes

Endhole Design

TM35 3.5 12 Yes Closed

TM35OE 3.5 12 Yes Open

UROLOGY

Page 17: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 17

Little Herbert® Luer Lock Adaptor

Features:• Allowsforfirmconnectionofdrainagelinestourinarycatheterswithoutinterfering

with the comfort factor. Sterile

Code DescriptionTCLLA StandardfemaleLuerlockfittingwithbarbedinsertionend

UROLOGY

Page 18: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES18

FOLEY CATHETERS (SILICONE)

Foley Catheters allow continuous drainage from the urinary bladder and are also for contrast studies of the urodenital tract. Silicone’s inert and non-irritating properties allow for medium to long term placement of these catheters. Silicone is less irritating than other materials to the mucosal lining of both the urethra and the urinary bladder. These catheters vary in length; the longer ones are typically used for males and the shorter ones for females.

Theballoonsonthesecathetersshouldbefilledwithsterile water only and aid in keeping the catheter in place. The balloons are porous toairandwillnotstayinflatedwhenplacedinsideanybodycavity.Sterilesalineshould not be used either. The saline will eventually form crystalsinsidetheballoonandwillcausedamagetoit,causingittoleakorblocktheinflationline.

Forcontraststudies(radiographicstudies),thecatheterisinsertedintotheurethra,theballooninflatedwithsterilewater,andanionicorganic iodide contrast medium is injected into the catheter while a series of radiographs are taken. These contrast studies are typically performed to look for narrowing of the urethra, or tumors in the urinary bladder.

Economy ClearView Foley Catheters (Silicone)

Features:• Closed-end silicone catheter with distal balloon. Ribbed balloon provides even

inflationandaidsinretainingthecatheterinsidethebladder.• Recommended only to be used with PTFE coated wire guides• Sterile• Reusable and autoclavable• Colour coded for easy reference.

Code French Size Length(cm)

Balloon Size (cc)

Colour

CFC530 5 30 1 Pink

CFC555 5 55 1 Pink

CFC630 6 30 1.5 Brown

CFC655 6 55 1.5 Brown

CFC830 8 30 3 Blue

CFC855 8 55 3 Blue

CFC1030 10 30 3 Black

CFC1055 10 55 3 Black

CFC1255 12 55 5 White

CFC1455 14 55 30 Green

CFC1655 16 55 30 Orange

CFC1855 18 55 30 Red

CFC2065 20 65 30 Yellow

CFC2265 22 65 30 Purple

UROLOGY

ClearView PTFE Coated Wire Guide

Code Outer Diameter (in)

Length (cm)

For use with CFC Catheters

TCGW2170 0.021” 70 5 Fr & 6 Fr

TCGW3570 0.035” 70 8 Fr

TCGW3870 0.038” 70 10 Fr

TCGW38180 0.038” 180 10 Fr

Page 19: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 19

Premium Foley Catheters (Silicone)

Code French Size Length(cm)

Balloon Size (cc)

Colour

FC630 6 30 2 Grey

FC655 6 55 2 Grey

FC830 8 30 5 Blue

FC855 8 55 5 Blue

FC1030 10 30 5 Black

FC1055 10 55 5 Black

FC1230 12 55 10 White

FC1255 12 55 10 White

FC1455 14 55 10 Green

FC1655 16 55 20 Orange

FC1855 18 55 20 Red

FC2065 20 65 30 Yellow

FC2265 22 65 30 Purple

SFC2875Stallion

28 75 50

SFC28100 Stallion

28 100 50

Features:• Closed-end silicone catheter with distal balloon cuff used for intermittent drainage of urine from

the bladder or contrast studies of urogenital tract.• Balloon aids in retaining the catheter inside the bladder• Recommended to be used with wire guide stiffening stylets.• Reusable and autoclavable• Silicone• Atraumatic• Radiopaque• Colour coded for easy size reference.

UROLOGY

Wire Guide Stiffening Stylets

Features:• Recommended to be used with Premium Foley Catheters. • Sterile• Autoclavable

Code Outer Diameter (in)

Length (cm)

For use with FC Catheters

WG1770 0.017” 70 5 Fr & 6 Fr

WG2560 0.025” 60 6 Fr

WG3860 0.038” 60 8 Fr

WG4560 0.045” 60 10 Fr & 12 Fr

Page 20: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES20

Central Venous Seldinger Catheter Sets

Code Feline DescriptionCVS301J Set consists of 3 Fr polyurethane catheter, 8cm long, 4 Fr vessel dilator,

30cm“J”wireguideand21ga,4cmlongneedle

CVS401J Set consists of 4 Fr polyurethane catheter, 10cm long, 5 Fr vessel dilator, 50cm“J”wireguideand20ga,4cmlongneedle

Central venous catheters (aka central venous lines) are used for venous pressure monitoring, collecting blood samples, and administering drugsand/orfluidstopatientsthatrequirelongtermtherapy.Thecatheteristypicallyplacedintothejugularvein,butotherperipheralsitesmay be used. These catheters are made from polyurethane which is soft enough to reduce the chance of injury and irritation to the wall of the blood vessel. The softness of the catheters also reduces the risk of causing a blood clot formation on the wall of the catheter. The cathetercanbeleftinthepatientforuptotwoweeksifpropercathetermaintenanceisperformed(regularflushingwithheparinizedsalineand proper protective dressing). Suture wings can be secured to the skin with sutures. Supplied sterile.

Features:• Used for venous pressure monitoring, blood sampling and administration of drugs

andfluids.• Intended to be introduced using the Seldinger Introduction Technique.• Use of the `J’ Wire Guide that is included allows you to pass the catheter into

specificvesselswhichcannotbeachievedwithacatheteralone.• Sterile

Code Canine DescriptionCVS501J Set consists of 5 Fr polyurethane catheter, 15cm long, 6 Fr vessel dilator,

50cm“J”wireguideand18ga,7cmlongneedle

Central Venous Peel-Off Sheath Catheter Sets

Features:• Central venous catheter introduced using a Peel-off sheathed needle.• The Peel-off sheath pre-loaded on the access needle allows percutaneous

introduction of the venous catheter, following direct venipuncture and removal of the needle cannula.

• After positioning the catheter, the sheath is peeled away.• Sterile

Code Canine DescriptionCVP308 Setconsistsof3Frpolyethylenecatheter8cmlong,matchedflexible

obturator, 19 ga, 7cm long Peel-off sheath needle and 10ml syringe

CVP4010 Setconsistsof4Frpolyethylenecatheter10cmlong,matchedflexibleobturator, 17 ga, 7cm long Peel-off sheath needle and 10ml syringe

CVP5015 Setconsistsof5Frpolyethylenecatheter15cmlong,matchedflexibleobturator, 15 ga, 7cm long Peel-off sheath needle and 10ml syringe

CENTRAL VENOUS CATHETERS

Page 21: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 21

Central Venous Peel-Off Sheath and Proximal Extension Catheter Sets

Code Canine DescriptionCVP70255 7 Fr polyurethane catheter 25cm long with 5cm proximal catheter

extension,amatchedflexibleobturator,a13ga,7cmlongPeel-offsheathneedle and a 10ml syringe

CVP85255 8.5 Fr polyurethane catheter 25cm long with 5cm proximal catheter extension,amatchedflexibleobturator,a12ga,7cmlongPeel-offsheathneedle and a 10ml syringe

Features:• Central venous catheter introduced using a Peel-off sheath needle.• The Peel-off sheath pre-loaded on the access needle, allowing percutaneous

introduction of the venous catheter, following direct venipuncture and removal of the needle cannula.

• After positioning the catheter, the sheath is peeled away. • Catheter can be trimmed if a shorter length is required.• Proximal extension assists with catheter manipulations after placement.• Sterile

CENTRAL VENOUS CATHETERS

Page 22: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES22

Chest Drainage Tubes

Code Tube I.D. (mm)

Tube O.D. (mm)

French Size

Length (cm)

Side Holes Over Distal of Catheter

CT12 2.3 4 12 42 5cm

CT14 2.9 4.7 14 42 7cm

CT20 4.0 6.6 20 42 10cm

CT30 7.0 10 30 42 12cm

Features:• Chestdrainagetubescanbeusedforthedrainageofairorfluid(hemo-,chylo-,pyo-,

pneumothorax).Hemothoraxisbloodinthethoraciccavity.Chylothoraxismilkyfluidconsisting of lymph and fat in the thoracic cavity. These tubes are placed by making an incision with a scalpel and bluntly dissecting through the muscle layers into the thoracic cavity.

• It is recommended to use with Metal Stiffening Stylets (MSS). The metal stiffening stylets are designed to be shorter than the catheter because the silicon tube will bunch up on itself when being pushed through the skin.

• Markings at 2 and 4cm from the last hole aid in correct positioning of catheter.• Multiplelargeholesfordrainingviscousfluids.• Reusable and autoclavable, supplied sterile• Silicone, reusable and autoclavable• Radiopaque• Sterile

* Product code PFLLA is recommended for use with CT12, CT14 and CT20* Product code PFLLAL is recommended for use with CT30

Pneumothorax Sets

Features:• Pneumothorax sets are used to treat tension or spontaneous pneumothorax which

isairinthethoraciccavity.Airinthethoraciccavitymakesitmoredifficultfortheanimal to breathe. Tension pneumothorax occurs when air escapes into the pleural cavity from a bronchus, but cannot regain entry into the lungs. This continuous increase of air pressure in the pleural cavity advances the collapse of the lung. Spontaneous pneumothorax is of unknown cause. The polyurethane catheter is placed with a direct puncture between the 7th and 8th rib. It is always important that when the catheter is introduced that there is a closed stopcock on the end opposite that is being inserted to stop the intake of air into the thoracic cavity. It works best to pull the skin forward before puncture, the skin will help seal off an external air from entering once it is released. After the tube is secured, bandaged, suction will be applied via a continuous suction unit, manual syringe technique or via a Heimlich One-Way Valve (HV100)

• Design allows rapid placement in an emergency.• Luer lock connector on end is ideal for hooking up to suction or Heimlich One-Way

Valve.• Can stay in for about 15 days.• Radiopaque• Sterile

Code French Size Catheter Length (cm)

Introduction Needle Stylet Length

TPT815 8.3 35 15

TPT1020 10 40 20

WOUND MANAGEMENT

Page 23: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 23

Multi-Purpose Drainage Tube

Features:• The Multi-Purpose Drainage Tube is used as an extension to indwelling drainage

catheters or pressure lines. It can be used to connect urinary catheters to closed collection bags, drainage tubes to suction, nasal catheters to oxygen etc. The polyvinyl chloride (PVC) tube consists to two tapered adapters of different sizes, tubingwithluerlockfittingsandastopcock.Itcanbeusedasawholeor disassembledtousetheindividualfittings.

• Sterile

Code French Size Length (cm)APFT1455 14 55

Thoracic Drainage Catheter

Features:• Thispolyvinylcathetercanbeusedforthedrainageoffluidfromthethoracicor

abdominal cavity. This catheter is more rigid than the CT and can be introduced with a puncture technique rather than a blunt dissection like the CT. The trocar for this catheter is inserted into the side of the catheter rather than travel down the entire catheter. This makes it much easier to hold in one’s hand. The user can have the end of the trocar in the palm of their hand to easily and more safely place the catheter with a puncture technique.

• Short, thick trocar for controlled introduction of the catheter.• Extra large side holes over a short distance on the distal end of the catheter.• Slightly blunted tip that aids in entering pleural lining.• Luerlockfittingonendcanbeconnectedtoasuctionapparatus.• Radiopaque• Sterile

Code French Size Catheter Length (cm)

Introduction Needle Stylet Length

TPT1230 12 30 12

TPT1630 16 30 12

Two-Part Drainage Catheter Sets

Features:• ThisPolyurethanecathetercanbeusedforthedrainageoffluidfromthethoracic

or abdominal cavity. It is generally introduced using a direct puncture technique, however it can also be introduced via dissection and a blunt trocar. Once the distal end of the trocar stylet and catheter are within the cavity, the catheter is detached from the trocar stylet and advanced off the trocar stylet and into the position.

• Multiple large side holes facilitate drainage of pus, blood or chyle.• Radiopaque• Sterile

Code French Size Catheter Length (cm)

TDC1030 10.2 30

TDC1230 12 30

WOUND MANAGEMENT

Page 24: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES24

Heimlich One-Way Valve

Features:• A one way valve to be used in conjunction with a chest tube or pneumothorax set

forthereliefofpneumothoraxinanimalsusuallyover10kg.Aircanonlyflowinonedirection through the valve. As the animal breathes in, the air in the pleural cavity is forced out of the chest tube and through the Heimlich valve. The pneumothorax will thereforeresolveitself.Itisstronglyrecommendednottousethisdeviceiffluidispresent in the chest because the duck bills in the valve will stick together.

• The HV100 Heimlich Valve comes complete with the valve and connecting tube ready to connect to a variety of chest tubes used to treat pneumothorax.

• Sterile

Code DescriptionHV100 Heimlich One-Way Valve

Pericardiocentesis Catheter Set

Features:• Thiscathetersetisusedtodrainfluidfromthepericardialsac.TheSeldinger

technique offers a greater level of safety than direct needle puncture. With the animal in lateral recumbency, the needle is introduced through the fourth intercostal space and should be advanced slowly towards the heart. Resistance will be felt from the pericardium, then a sudden release as it is penetrated. If the needle touches the myocardium, premature ventricular contractions will be seen on an ECG monitor. Once in place, thread the wire guide through the needle into the pericardial sac and remove the needle. The dilator can be used to open up a tract through the skin if necessary. The catheter pigtail is then unrolled over the thumb and threaded onto the wire guide and down into the pericardial sac. When thewireguideisremoved,thepigtailconfigurationretainsthecathetertipwithinthe sac.

• FEP(fluorinatedethylenepropylenecopolymer)• Sterile

Code DescriptionPCS911 Set includes 8.2 Fr, 20cm long catheter with six distal side holes, an 18 ga,

7cmlongintroductionneedleanda0.038”diameter,60cmlongwireguide

Pericardiocentesis Needle & Catheter

Features:• Usedtodrainfluidfromthepericardialsac.• FEP(fluorinatedethylenepropylenecopolymer)catheter.• Sheath and needle are inserted into vessel together.• Sterile

Code French Size Length(cm)

Gauge Needle Length (cm)

PCS1415 8.2 15 14 18

WOUND MANAGEMENT

Page 25: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 25

WOUND MANAGEMENT

Broncho-Alveolar Lavage Catheter (Silicone)

Features:• TheBALcatheterisusedforlunglavageand/orcollectionofaspecimenfromspecific

lungfields.Thiscatheterisusedonanimalsundersedation,mostcommonlyhorses.Thecatheterisequippedwithaballoonattheendthatcanbeinflatedtopreventretrogradefluidflowandaproximaltwo-wayfittingallowssimultaneousconnectionforboth irrigation and aspiration.

• Reusableandautoclavable-however,theplasticproximaltwo-wayfittingmustberemoved.

• Replacement balloon cuffs (RK7) and silicon adhesive (ADH2) are available.• Replacementinflationlines(RILS)available.• The three-way stopcock (STC3WSLIP) provided is not autoclavable and intended for

one time use.• Sterile

Features:• Usedforthelavageofselectedsegmentsofthelungfields.• Polytetrafluroethylene(PTFE)catheterwithendholeandfemalelueratthe

opposite end.• Non-autoclavable (best to use ethylene oxide sterilisation).• Radiopaque• Sterile

Code French Size Tube I.D.(mm)

Tube O.D. (mm)

Length (cm)

BAL240 30 3 11 240

BAL300 30 3 11 300

Canine Broncho-Alveolar Lavage Catheter

Code French Size Length (cm)CBAL5190 5 190

CBAL6125 6 125

Guttural Pouch Endoscopic Flushing Catheter

Features:• The catheter is endoscopically guided for the lavaging of lungs or the guttural pouch

toremovedebris.Thegutturalpouchisalargeair-filledsacinthenarrowchannelthat connects the nasopharynx to the middle ear in the horse. The paired sacs cause swelling in the region below the ear when distended. Several large vessels and nerves run over this area and are susceptible to disease of the pouch. This is usually a quick procedure where the catheter is not left it.

• Visual indicators at 2.5, 5 and 7.5cm from the distal tip aid in introduction.• PTFE catheter• Sterile

Code French Size Length (cm) Distal Tip MarkingsEFC5170 5 170 Yes

EFC5250 5 250 Yes

EFC6250 6 250 Yes

EFC6330 6 330 Yes

EFC7250 7 250 Yes

Page 26: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES26

Peritoneal Lavage Catheter

Features:• This catheter is used to infuse and withdraw rinsing solutions in body cavities in

cases of blunt trauma or therapeutic use. The set consists of a catheter with six distal side holes, introduction needle and a wire guide. Peritoneal lavage may be indicated for a case of pancreatitis, peritonitis, hemoperitoneum, uroperitoneum etc. This catheter is almost identical to the PCS911, except it is bent 45 degrees at the distal tip.

• FEP(fluorinatedethylenepropylenecopolymer)• Sterile

Code DescriptionPLS100 Set includes 8.2 Fr, 20cm long catheter with six distal side holes, an 18 ga,

7cmlongintroductionneedleanda0.038”diameter,60cmlongwireguide

Continuous Suction Bulbs

Features:• Continuous suction bulbs allow short-term suction to be applied to body cavities,

enablingthedrainageofeitherairorfluid.Sinceitisacloseddevice,thereisnomess associated with it like there is with penrose drains etc.

• Clearsoyoucannotethecharacteristicsofthefluidthatyouarecollecting.• Similar to the human drainage systems that are pre-packaged with a continuous

suction bulb but only one type of tubing. Our Suction Bulbs are sold separately to be used with your choice of tubing.

• Ideal for use in small animals.• Side tab allows the device to be anchored to the body by either bandage or tape.• Onewayvalveandluerlockfitting.• Silicone• Sterile

Code SizeGSB100 100 cc

GSB150 150 cc

GSB400 400 cc

WOUND MANAGEMENT

Closed Wound Vacuum Drains (Silicone)

Features:• Used for post-operative drainage. • May be used in conjunction with closed wound vacuum devices.• Very popular wound drain.• Radiopaque• Ideal for use with Continuous Suction Bulb shown on page 27• Sterile

Code Drainage Tube Length (cm)

Width (mm)

Multiple Fenestrations

Rounded Conn. Tube (cm)

CWVD0720 20 7 Yes 60

CWVD1320 20 13 Yes 60

Page 27: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 27

WOUND MANAGEMENT

Fenestrated Catheter Wound Drain

Code French Size Length (cm)FCWD25 8 25

Features:• Suitable for post-orthopaedic wound drainage.• Polyurethane Catheter• Radiopaque• Sterile

Features:• May be trimmed or used as one piece for surgical wound drainage. • Drain can be split along length or trimmed to suit individual requirements.• Reusable and autoclavable• Radiopaque• Autoclavable• Sterile

Flexi-Drain Multi-Purpose Wound Drain (Silicone)

Code Lumen Diameter (mm)

Drainage Tube Length (cm)

Joined Catheter Lumens

WD1240 3 40 12

Page 28: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES28

Stopcocks (Sterile)

OWS100 STC3WSTC1W STC3WSLIP

Code DescriptionOWS100 One-way plastic stopcock, female Luer lock to male Luer lock

STC3W Three-way plastic stopcock, two female Luer locks to male Luer lock with right side arm

STC1W One-way plastic stopcock, female Luer slip to male Luer slip

STC3WSLIP Three-way plastic stopcock, two female Luer slips to one male Luer slip

PFLLAL PMLLALPFLLA P412 & P79

Theseadaptors,alsoknownas“ChristmasTrees”facilitatetheconnectionofdifferentdiametertubingtoluerlockdevicessuchassyringesorcatheterfittings.Exampleswouldbesiliconechesttubestosuctionornasogastrictubestooxygentubingforintranasaloxygendelivery.The PFLLAL is the most popular adapter and is commonly used to assist syringe feeding via a silicone nasogastric tube or a PEG tube, injection of a foley catheter for bladder studies, or connecting a foley to a closed collection bag. The double ended variety adaptors allow different diameter tubing to be joined together.

Multi Purpose Tubing Adaptors (Sterile)

Code DescriptionPFLLA Female Luer lock to tapered catheter end - Fitting accepts 10-20 Fr I.D.

PFLLAL Female Luer lock to large tapered catheter end - Fitting accepts 20-40 Fr I.D.

PMLLAL Male Luer lock to large tapered catheter end - Fitting accepts 20-40 Fr I.D.

P412 Double-ended tapered connector - Fitting accepts 4-12mm I.D.

P79 Double-ended tapered connector - Fitting accepts 7-9mm I.D.

CONSUMABLE PRODUCT ACCESSORIES

Page 29: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 29

CONSUMABLE PRODUCT ACCESSORIES

Injection Ports (Sterile) Luer Lock Plug (Sterile)

VIP2 LLP100

Code DescriptionVIP2 Luer lock cap to allow injection of solutions through cap

LLP100 Luer lock plug to occlude female Luer lock

Clamps (Sterile)

CLAMPWS CLAMPWL

Code DescriptionCLAMPWS Clamp to occlude drainage catheter tubing - For use with tubing up to 5mm O.D.

CLAMPWL Large clamp to occlude drainage catheter tubing - For use with tubing 12.7 - 16mm O.D.

Fixation Disc (Sterile)

Silicone Adhesive (Non-Sterile)

Features:• Recommendedforusewhenrepairingsiliconecuffsandinflationlineson

endotracheal tubes and BAL Tubes.• 2.8oz tube of silicone adhesive

Code DescriptionADH2 Silicone Adhesive 2.8oz

Code DescriptionFD100 Silicone Fixation Disc

Features:• Siliconefixationdisc• Used to stabilise percutaneous drainage catheters.• Sterile

Page 30: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES30

Endotracheal Tube Stylet with Stopper

Features:• Stainless steel endotracheal tube stylet with silicone stopper• Non-sterile• Autoclavable• Malleable

Code Fits (mm)VSTYLSM 2.5 - 5.5

VSTYLLG 5.5 - 9.5

ClearView PTFE Coated Wire Guide

Features:• Recommended to be used with Economy Clearview Oral/Nasal Oxygen/Feeding

Tubes and Clearview Foley Catheters. • Sterile• Autoclavable

Code Outer Diameter (in)

Length (cm)

For use with CFC Catheters &

Feeding TubesTCGW2170 0.021” 70 5 Fr & 6 Fr

TCGW3570 0.035” 70 8 Fr

TCGW3870 0.038” 70 10 Fr

TCGW38180 0.038” 180 10 Fr

Wire Guide Stiffening Stylets

Features:• Recommended to be used with Premium Foley Catheters. • Sterile• Autoclavable

Code Outer Diameter (in)

Length (cm)

For use with FC Catheters

WG1770 0.017” 70 5 Fr & 6 Fr

WG2560 0.025” 60 6 Fr

WG3860 0.038” 60 8 Fr

WG4560 0.045” 60 10 Fr & 12 Fr

CONSUMABLE PRODUCT ACCESSORIES

Page 31: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 31

Features:• Recommended to be used with Premium Foley Catheters. • Sterile• Autoclavable

CONSUMABLE PRODUCT ACCESSORIES

Metal Stiffening Stylets

Features:• Solid stainless steel rod / stiffening stylet• Recommended for use with Chest Drains• Autoclavable• Non-sterile

Code Outer Diameter (mm)

Length (cm)

For use with CT Catheters

MSS12 1.3 40 12 Fr

MSS14 2.3 40 14 Fr

MSS20 3.2 40 20 Fr

MSS30 4.7 45 30 Fr

Stainless Steel Threaded Wire Guides

Features:• Non-sterile• Autoclavable

Code Outer Diameter (mm)

Length (cm)

GTI070TW 1 70

GTI110TW 1 110

Introduction Tubes

Features:• Non-sterile• Autoclavable

Code Outer Diameter (mm)

Length (cm)

GTI545IT 5 45

GTI9545IT 9.5 45

Page 32: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES32

AAdaptor Airway (ETC, 32121B) 6 Little Herbert® Luer Lock Adaptor (TCLLA) 17Adhesive, Silicone (ADH2) 29

BBag to Bag Connectors (LACTEC3) 12Biopsy Needle, Vet-Core (VC) 14Broncho-Alveolar Lavage Catheter (BAL & CBAL) 25

CCatheter Broncho-Alveolar Lavage Catheter (BAL & CBAL) 25 Economy ClearView Foley Silicone (CFC) 18 Equine Urine Flushing (VEUF) 15 Guttural Pouch Endoscopic Flushing (EFC) 26 Pericardiocentesis Needle, Set (PCS1415) 24 Set (PCS911) 24 Peritoneal Lavage (PLS100) 26 Premium Foley Silicone (FC, SFC) 19 Slippery Sam™ Tomcat Urethral (TTM) 16 Subcutaneous Set (FSQ) 13 Thoracic Drainage (TPTL) 23 Tomcat Urethral Silicone (TM) 16 Two-Part Drainage Set (TDC) 23Central Venous Catheter Set Peel-Off Sheath (CVP) 20 Peel-Off Sheath & Proximal Extension (CVP) 21 Seldinger (CVS) 20Chest Drainage Tube (CT) 22Clamps (CLAMPW) 29ClearView Economy Oral/Nasal Feeding Tube (CFT) 9 Foley Catheter (CFC) 18 PTFE Coated Wire Guide (TCGW) 30Closed Wound Vacuum Drain Silicone (CWVD) 26Connecting Tube (CT, CTU) 12Connectors Bag to Bag (LACTEC3) 12 Endotracheal Tube 6Continuous Suction Bulbs (GSB) 26Cuffed Endotracheal Tubes 4-7Cuffed Wire Reinforced Endotracheal Tube (V35W, JET) 4

DDrain Closed Wound Vacuum Silicone (CWVD) 26 Fenestrated Catheter Wound (FCWD25) 27 Flexi-Drain Multi-Purpose Wound (WD1240) 27

EEconomy ClearView Foley Silicone (CFC) 18 ClearView Economy Oral/Nasal Feeding Tube (CFT) 9Equine Fluid Delivery System (VEFD16) 15 Post Anaesthetic Nasal Tube Silicone (ENAT) 7 Sacral Joint Needle (ESJN1525) 14 Uterine Flushing Catheter (VEUF) 15Endoscopic Flushing Catheter Guttural Pouch (EFC) 25Endotracheal Tube Metal Connectors (32121B) 6 Cuffed Silicone (ET) 5 Cuffed Wire Reinforced Silicone (V35W, JET) 4 Foal Silicone (FN) 7 Non-Cuffed Silicone (AT) 3 Non-Cuffed Wire Reinforced Silicone (ATR) 4 Porcine 7 Stylet with Stopper (VSTYL) 4

FFeline Oesophagostomy Tube Silicone (FET) 8 Orogastric Feeding Tube (FOT) 11Fenestrated Catheter Wound Drain (FCWD25) 27Fixation Disc (FD100) 29Foley Catheters 18-19Flexi-Drain Multi-Purpose Wound (WD1240) 27Fluid Delivery System, Equine (VEFD16) 15Foal Nasal Tube Silicone (FN) 7Foley Catheter Silicone Economy ClearView (CFC) 18 Premium (FC, SFC) 19

GGastrostomy Tube Introduction Set (GTIS) 10Guttural Pouch Endoscopic Flushing (EFC) 26

HHeimlich One-Way Valve (HV100) 24

IInfusion Sets, Wide Bore (LACTEC1, 2, 4) 12-13Injection Ports (VIP) 29Introduction Tube (GTIXXXIT) 31

LLittle Herbert® Luer Lock Adaptor (TCLLA) 17Luer Lock Plug (LLP100) 29

MMulti-Purpose Drainage Tube (APFT1455) 23 Multi-Purpose Tubing Adaptors (PFLLA,PFLLAL,PMLLAL) 28

PRODUCT INDEX

Page 33: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 33

PRODUCT INDEX

NNasal Tube Silicone, Foal (FN) 7Needles Equine Sacral Joint (ESJN1525) 14 Peel-off Sheath (NPOS) 14 Vet-Core Biopsy (VC) 14Non-Cuffed Endotracheal Tube Silicone (AT) 3Non-Cuffed Wire Reinforced Endotracheal Tube Silicone (ATR) 4

OOesophagostomy Catheter (OTC) 8 Tube, Feline (FET) 8 Tube Set (OTCS) 8One-Way Valve, Heimlich (HV100) 24Oral/Nasal Oxygen/Feeding Tube Economy Clearview (CFT) 9Orogastric Feeding Tube, Feline (FOT) 11

PPeel-off Sheath Needles (NPOS) 14Peg Feeding Tube (PT) 10Pericardiocentesis Needle and Catheter (PCS1415) 24 Set (PCS911) 24Peritoneal Lavage Catheter (PLS100) 26Pneumothorax Set (TPT) 22Porcine Endotracheal Tube 7Premium Foley Silicone (FC, SFC) 19

RReplacementInflationLine(RILS,RILL) 6Repair Cuff (RK) 6

SSilicone Adhesive (ADH2) 29Slippery Sam™ Tomcat Urethral (TTM) 16Spiked Wide Bore Infusion Sets (LACTEC2, LACTEC4) 13Stopcocks (OWS, STC) 28Stylet Endotracheal Tube with Stopper (VSTYL) 4 Metal Stiffening (MSS) 31 Wire Guide Stiffening (WG) 30Subcutaneous Catheter Set (FSQ) 13Suction Bulbs, Continuous (GSB) 26

TThoracic Drainage Catheter (TPTL) 23Tomcat Urethral Catheter Silicone (TM) 16Tomcat Urethral Slippery Sam,™ (TTM) 16Tracheostomy Tube Silicone (V600XX) 7

TTube Chest Drainage (CT) 22 Connecting 12 Post Anaesthetic Nasal Silicone (ENAT) 7 Endotracheal 3-7 Feline Orogastric Feeding 11 Foal Nasal 7 Gastrostomy 10 Introduction (GTIXXXIT) 31 Multi-Purpose Drainage 23 Oesophageal 8 Oesophagostomy 8 Oral/Nasal Oxygen/Feeding 9 Peg Feeding 10 Tracheostomy 7Two-Part Drainage Catheter Set (TDC) 23

UUterine Flushing Catheter, Equine (VEUF) 15

VValve, Heimlich One-Way (HV100) 24Vet-Core Biopsy Needle (VC) 14

WWide Bore Infusion Sets (LACTEC1, 2, 4) 12-13Wire Guide ClearView PTFE Coated (TCGW) 30 Stainless Steel Threaded (GTIXXXT) 31 Stiffening Stylet (WG) 30Wire Reinforced Endotracheal Tube Non-Cuffed Silicone (ATR) 4Wire Reinforced Endotracheal Tube Cuffed Silicone (V35W, JET) 4

Page 34: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES34

NOTES:

Page 35: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SURGIVET™ CRITICAL CARE CONSUMABLES 35

NOTES:

Page 36: 4VSHJ7FU$POTVNBCMFT$BUBMPHVFsoundvet.com.au/wp-content/uploads/2015/04/SVE... · ET24 RILL RK24 32121B7 ADH2 ET26 RILL RK26 32121B8 ADH2 ET30 RILL RK30 32121B9 ADH2 AIRWAY MANAGEMENT

SurgiVet™ Critical Care Consumables

Sound Veterinary equipment pty ltd p.o. box 2916, rowVille Vic 3178

unit 4, 19 cornHill St, Ferntree Gully Vic 3156 auStralia p: 1300 881 681 or +61 3 9758 2500 | F: 1300 881 682 or +61 3 9758 1881 E: [email protected] | W: www.soundveterinary.com.au