4” svg coat and develop trackmfz140.ust.hk/eq_manual/svg coat and develop track... ·...
TRANSCRIPT
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 1 of 15
Standard Operating Manual
4” SVG Coat and Develop Track
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 2 of 15
Contents
1. Picture and Location
2. Process Capabilities
2.1 Cleanliness Standard
2.2 Substrate Size
2.3 Substrate Material
2.4 Photoresist
2.5 Develop
2.6 Spin Speed
2.7 Hotplate Temperature
2.8 Baking Time
3. Contact List and How to Become a Qualified User
3.1 Emergency Response and Communications
3.2 Training to Become a Qualified User
4. Operating Procedures
4.1 System Description
4.2 Safety Warning
4.3 Operation Precautions and Rules
4.4 Initial Status Checks
4.5 Initial System Checks
4.6 Photoresist Coat operation Procedure
4.6.1 Loading a program
4.6.2 Cleaning the Photoresist Dispense Nozzle
4.6.3 Loading the cassette
4.6.4 Starting the process
4.6.4.1 Dynamic dispense
4.6.4.2 Manual dispense
4.6.5 Unloading the wafer
4.7 Photoresist Develop Operation Procedure
4.7.1 Loading a program
4.7.2 Loading the cassette
4.7.3 Starting the process
4.7.4 Unloading the wafer
4.8 Clean Up
4.9 Check Out
4.10 SVG Track Recipe
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 3 of 15
4” SVG Coat and Develop Track
1. Picture and Location
Fig.1 This tool is located at NFF Phase II Cleanroom Class 100.
2. Process Capabilities
2.1 Cleanliness Standard: Clean/Semi-Clean
2.2 Substrate Size: 4” round wafer
2.3 Substrate Material: Silicon, Metal coated Quartz
2.4 Photoresist: Dynamic resist dispense for FuJi Film HPR504
Manual resist dispense for NFF standard resist
2.5 Develop: FHD-5
2.6 Spin Speed: ≤ 4000rpm
2.7 Hotplate Temperature: 105°C (HMDS), 110°C(soft bake) and 120°C (hard
bake)
2.8 Temperature accuracy: +/-0.1°C
2.9 Baking Time: 60, 120, 180 and 300 sec
3. Contact List and How to Become a Qualified User
3.1 Emergency Response and Communications
1. Security Control Center: 2358-8999 (24hr) & 2358-6565 (24hr)
2. Safety Officer: Mr. Wing Leong CHUNG 2358-7211 & 64406238
3. Deputy Safety Officer: Mr. Man Wai LEE 2358-7900 & 9621-7708
4. NFF Senior Technician: Mr. Henry YEUNG 2358-7896
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 4 of 15
5. NFF Technician: Mr. Charles TANG 23587896
3.2 Training to Become a Qualified User
Please follow the procedure below to become a 4” SVG Coat and Develop Track
qualified user.
1. Read through the on-line equipment operating manual of the equipment;
http://www.nff.ust.hk/equipment-and-process/equipment-operation-manual.ht
ml
2. Attend the equipment hand-on operation training either by peer or NFF staff.
3. If training is provided by NFF staff, user must log in NFF equipment
reservation system, and register these trainings.
4. Send an e-mail to Mr. Henry YEUNG requesting 4” SVG Coat and Develop
Track qualified exam.
5. Pass the examination for the equipment operation and security.
4. Operating Procedures
4.1 System Description
The Silicon Valley Group (SVG) 8600 Series Track is a 4” photoresist coat and
develop wafer track (Fig.2). The photoresist coat line is closest to the operator
and runs from left to right. The develop line is further away from the operator
and runs from left to right also. The photoresist coat line contains four modules,
HMDS Prime oven, cool plate, spinner and soft bake oven. The photoresist coat
line is controlled by the left and the middle controller. The left controller
manages HMDS and cool plate. The middle controller manages spinner and soft
bake oven (Fig.3). The develop line contains two modules, spinner and hard bake
oven. They are controlled by the right controller (Fig.4).
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 5 of 15
1. 4” SVG Track Figure
Fig.2 4” Photoresist coat and develop wafer track
2. Coat Track Controller
Fig.3 Coat and soft bake oven controller
Station Select Program Select
Develop Send Indexer Coat Send Indexer
Develop Receive Indexer
Coat Receive Indexer
Coat Cover
Temperature Controllers Coat Controllers Develop Controller
HMDS
Cool plate Soft bake
Hard bake
Develop
EMO
Event Select
Power Button Index Reset Button
Start Button
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 6 of 15
3. Develop Track Controller
Fig.4 Develop and hard bake oven controller
Power button: Applies all operating voltages from the power supply module to the
card cage and the mechanical track.
Start: Begins processing of wafers if a loaded cassette is in place on the send indexer.
Restarts processing after any STOP command.
Station Select: Use to access either the spin or bake process station for programming.
Program Select: Use to select one of the nine process programs store in RAM
memory.
Event Select: Used to display the operation and associated process parameters
programmed for any of the nine possible events or steps in a designated process
program.
Index Reset: Depress INDEX RESET once. Send indexer is returned to top position.
Depress INDEX RESET twice. Receive cassette is returned to top position.
4.2 Safety Warning
1. Follow NFF Health and Safety Manual.
2. Never operate the system with covers removed.
3. Never operate system without trained and approved by NFF staff.
4. Never operate the system without exhaust.
5. Covers and process cups may only be removed by authorized personnel!
6. Do not place your hand in the path of the track’s moving parts and indexer.
Index Reset Button
Start Button
Power Button Station Select Program Select
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 7 of 15
7. Resists may have irritating effects to eyes, skin and mucous membranes! Read
and obey Material Safety Data Sheet (MSDS) of the corresponding materials
used in the system!
8. The substrate, the hotplate and its cover are hot. Touching can lead to skin burns.
9. If an error or problem occurs, stop all work immediately. Leave notice that the
machine is not to be used and contact the staff. Do not attempt to fix the problem.
10. The Emergency Off – Button (EMO Button) shuts down the machine
immediately. Only use the EMO in emergency situations. Emergency situations
are where injury of personnel or serious damages of the system impends
immediately.
11. According to the general fire emergency procedure of HKUST, please report the
accident to the Security Control Center first. The nature of other emergencies will
determine whether you will call police, staff, or both. If someone is injured, the
9-999 emergency number should be called before calling staff. If there is a facilities
problem, such as a flood or a utility problem that does not present a danger to lab
users but may result in damage to equipment, the staff or FMO need to be called.
The 9-999 emergency should not be called for facility or equipment problem.
Always call 9-999 when a potentially life threatening situation might exist (injury,
fire, gas leak, etc.)
4.3 Operation Precautions and Rules
1. Do not operate the equipment unless you are properly trained and approved by
NFF Staff.
2. Please check the checklist and fill all the details of the log sheet attached.
3. Wipe with a fresh cleanroom wiper with Acetone or IPA to clean the rim of resist
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 8 of 15
bottle after each use if manual apply the photoresist to your wafer.
4. Return small resist bottle back to assigned small resist bottle storage cabinet after
each use.
5. Do not remove the cassette if the elevator is not at the top.
6. No temperature change of the hotplate stations.
7. Use NFF standard photoresist only, No polyimide, No double side coating, No
SU8, No LOL2000 and No PDMS in this track.
8. Remember to place the wafer face up.
9. Close the coater cover doors after each use.
10. All recipe programming is done by NFF Staff. If you need a special recipe, you
may request a new recipe to Staff.
4.4 Initial Status Checks
1. Please check the status of shutdown notice posted in the NFF reservation
website.
2. Please check-in the equipment via card reader.
3. Before operate the machine, please check the checklist and fill all the details of
the log sheet attached.
4.5 Initial System Checks
Before starting, verify the machine is in the correct idle state:
1. Verify the system is Power ON. If machine is off, do not reboot. Contact staff on
the “contact list”.
2. Verify that exhaust systems are properly connected.
3. Check photoresist waste container is not full under track.
4. Check the HPR 504 supplied is not empty under track (Fig.5).
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 9 of 15
Fig.5 HPR504 and Waste Container
5. Check track is in AUTO mode for Coater and Develop line. You can choose
“AUTO” mode by pressing the Manual-Single-Auto key until the LED light
next to “AUTO” is illuminated.
6. Verify the track is in the standby state. There should no wafers are processing
and the elevator of indexer at the top position.
7. Make sure that no objects are blocking the path of the moving parts.
8. Check the hotplate temperature (Fig.6).
Fig.6 HMDS, Soft Bake, Hard Bake oven controller
4.6 Photoresist Coat Operation Procedure
4.6.1 Loading a program
1. Select your desired HMDS program.
HMDS Soft Bake Hard Bake
HPR504 Waste Container
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 10 of 15
If you need HMDS, select Program 1, press number 1 followed by the
PROGRAM SELECT button or scroll through all programs by pushing the
PROGRAM SELECT button repeatedly until the desired program is displayed
on left controller. Other programs are not HMDS.
2. Select your desired dispense program.
Note that the middle controller is 2 separate display windows on the control
panel. The upper display window shows parameters for Coater. The lower
display window shows parameter for OVEN. In order to select the dispense
program, the COATER display is selected, a “*” sign appears at the left of the
COATER display and when the OVEN display is selected, a “+” sign appears at
the left of the OVEN display. You can press “STATION SELECT” button to
switch between the active displays for COATER or OVEN controller on the
control panel keyboard. To select different programs, please see above
instruction.
3. Select your desired oven program.
Active the OVEN display and select desired program as above instructions. The
OVEN is 110°C fixed.
4.6.2 Cleaning the Photoresist Dispense Nozzle
The coat track is set to dispense FujiFilm HPR504 positive photoresist. If you
need manual to pour photoresist, you can skip this section.
1. A resist nozzle that has not been used for more than 30mins. The dried resist
may be formed at its tip to affect the uniformity and cause the particulate
problem.
2. Take an acetone squirt bottle from the Acetone/IPA cabinet and cotton stick
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 11 of 15
from cotton stick storage box.
3. Wipe the nozzle with acetone moistened cotton stick before running your
dummy wafer. (Remember gently to wipe the nozzle).
4. Return the acetone squirt bottle back to the cabinet and dispose used cotton
stick.
4.6.3 Loading the cassette
1. If necessary, press INDEX RESET button once to bring the send
indexer up to top position, or twice for the receive indexer up to top position. If
you press the INDEX RESET button, you must remove the cassettes completely
off the elevator and put them on the elevator to reset the send and receive
elevator purpose for the cassette to go down.
2. Load an empty cassette on the receive indexer (right side, Fig.7).
3. Load the cassette containing your device wafers (face up) and 1 or 2 dummy
wafers (at the bottom) on the send indexer (left side). The dummy wafers might
have some resists on the front side. If you re-use them, make sure the backside
without resist.
Fig. 7 Place cassette on Send Indexer and Receive Indexer
Send Indexer Receive Indexer
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 12 of 15
4.6.4 Starting the process
4.6.4.1 Dynamic Dispense
1. Press START button on the middle controller keypad. The receive cassette and
send cassette will lower until it senses a wafer. The wafer will be transferred to
the HDMS prime oven for priming, cool plate, spinner for the dispense
procedure, then to the OVEN for soft baking, and receive cassette.
2. The process step will be displayed on the display of controller.
4.6.4.2 Manual Dispense
1. Press START button on the middle controller keypad. The receive cassette
and send cassette will lower until it senses a wafer. The wafer will be
transferred to the HDMS prime oven for priming, cool plate and then spinner
(Fig.9).
2. Take out the desired standard photoresist bottle from standard photoresist
storage cabinet and pick a piece of polyester cleanroom wiper.
3. After wafer transfer to spinner, spindle lower down, open the coater cover door.
Pour the photoresist to the wafer (10sec for you to apply the photoresist). You
should cover at least the central 1/3 of the sample.
4. Close Coater Cover Door.
5. Wipe with a fresh polyester cleanroom wipe with Acetone to clean the rim of
resist bottle after each use.
6. The process step will be displayed on the display of controller
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 13 of 15
Fig. 8 The flow to pour the resist on the wafer
4.6.5 Unloading Wafer
1. After the track has finished processing all wafers, the receive indexer will not
move to the top. Do not remove the cassette if the elevator is not at the top.
2. Double click the INDEX RESET button on the middle controller to
move the receiver elevator to the top.
4.7 Photoresist Develop Operation Procedure
4.7.1 Loading a program
Follow the section 4.6.1
4.7.2 Loading the cassette
Follow the section 4.6.3
4.7.3 Starting the process
1. Press START button on the right controller keypad. The receive cassette and
Cool plate Open cover door and resist bottle
Pour resist Close cover door and clean rim
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 14 of 15
send cassette will lower until it senses a wafer. The wafer will be transferred to
the Develop Station for developing, oven for hard bake if you select, then
receive cassette (Fig.9).
2. The process step will be displayed on the display of controller.
.
Fig. 9 The flow to develop wafer
4.7.4 Unloading Wafer
Follow the section 4.6.
4.8 Clean Up
1. Dispose used cleanroom wiper to Rubbish bin and change the gloves if necessary.
2. Return dummy wafer photoresist bottle back to the original place
4.9 Check out
1. Check out the equipment via card reader immediately after use.
2. Fill in the details, problems or comments in the log sheet.
Puddle develop
Rinse Spin dry
Load wafer
NANOSYSTEM FABRICATION FACILITY (NFF), HKUST
Version 1.1 Page 15 of 15
4.10 SVG Track Recipe
Program Descriptions
PRIME / OVEN ( Track 1A )
1 HMDS prime, 105 C, 30 sec
2 – 9 Not used
COATER ( Track 1B) 1 Dynamic dispense, 4000 rpm, 30 sec. with front side and backside rinse
2 Manual dispense, 4000 rpm, 30 sec. with backside rinse only
3 Dynamic dispense, 4000 rpm, 30 sec. with backside rinse only
4 Manual dispense, 4000 rpm, 30 sec. with front side and backside rinse
5 – 7 Defined by users
6 Manual dispense, 4000 rpm, 30 sec. with backside rinse only
8 Front side and backside rinse
9 For spin speed checking
OVEN ( Track 1B ) for COATER 1 Soft bake, 110 ºC, 60 sec.
2 Soft bake, 110 ºC, 90 sec.
3 Soft bake, 110 ºC, 120 sec.
4 Soft bake, 110 ºC, 180 sec.
5 Soft bake, 110 ºC, 600 sec.
6 Proximity bake, 110 C, 60 sec
7 – 9 Not used
Developer ( Track 2A ) 1 For puddle develop 65 sec
2 For puddle develop 130 sec.
3 For puddle develop 65 sec.
4 For puddle develop 15 sec.
5 – 7 Not used
8 Rinse only
9 For spin speed checking
OVEN ( Track 2A ) for Developer 1 Hard bake, 120 C, 60 sec
2 Hard bake, 120 C, 90 sec
3 Hard bake, 120 C, 120 sec
4 – 9 Not used
ARM PROGRAM for COATER ( Track 1B ) 1 Move the arm to starting position of dynamic dispense
2 Arm motion for dynamic dispense
3 Move the arm to the home position
4 Move the arm to the wafer edge
5 Arm motion for removal the front side edge beam of the wafer
6 – 9 Not used