Clear figures at the press of a button.All data can be called up on a multifunctional LC display
The microchip in the doprimo ®
converts the readings into clearlydefined and easy-to-read figures.Moreover, the built-in storage capability permits readings to be buffer-stored and retrieved for evaluation.All the information in the doprimo ® can be retrieved in 3 display loops:
•Meter-reading loop “A1”
•Technician loop “A2”
•Statistics loop “A3”
The display loops are shown consecutively when the sensor button is pressed (longer than 3 sec.).If the button is not activated for alengthy period within one loop, thedisplay jumps back. The last place inthe first line indicates the displayposition.In normal mode there is no display.After 60 sec. without operation thedisplay also goes off (exception:meter fault). The display is re-activated by touching the sensorbutton.
88888 888888 88
88888 888888 88
12345 A12101
18345 b31.12.95 45
13456 C31.12.94 53
31 12 d1196
12 06 E1196 88
00000 F0C
b01.08.95
12221 G05.96
12101 G06.95
A1
A2
A3
A1
2
3
4
5
6
7
1
2
1
12
1
1
1
The meter-reading loop
Segment testActivates/Deletes all segments for 2 sec.
Current consumptionConsumption of month in previousyearPrevious year consumption
Key day and test number
Consumption of year before previous
Key day and test number
Key date
Current date
Fault code display
Test number
(Display ≠ 0 not necessarely fault)
The technician loopUnit/Product scale
Display of the Kk value
Starting date
The statistics loopMonth-end consumption (example)
of May 1996
Month-end consumption (example)...up to june 1995
Prolonged button activation
Short button activation
Periodical display change
Which meter for which range of application ?How to determine the mean heating medium temperature.
The doprimo ® has a digital opticalinterface for programming.
LC display
Optical interface
Sensor button
Remote sensor housing
doprimo ® compact doprimo ® remote sensor
Mean heating medium temperature
Heating system
Two-pipe heating system doprimo ® compact
Single-pipe heating system doprimo ® remote sensor1 user per section
Single-pipe heating system, verticalMore than 1 user per section
Single-pipe heating system horizontalMore than 1 user per section
0 10 20 30 40 50 60 70 80 90 100 110 120 °C
Determining the mean heating medium temperature
The formula The variables
tm = tL +tV - tR
tV - tL
tR - tL
ln
tm = tL + ∆tln
∆tln = Logarithmic excess temperature
tm = Mean heating medium temperature
tV = Inlet temperature of the radiator
tR = Return temperature of the radiator
tL = Reference ambient temperature
doprimo ® IITechnical dataMeter type doprimo II ®
Modes 2-sensor mode (automatic changeover to 1-sensor mode at t>25°C)
Dimensions • Compact meter 82.0 x 40.5 x 26.5 mm
• Remote sensor meter 134.0 x 88.0 x 36.4 mm
• Remote sensor housing 45.0 x 12.9 x 11.5 mm
• Length of the remote sensor cable: 3.0 m
Material • Meter housing: Novodur ABS
• Heat conductor: Cast zinc
Display • Two lines
1st line : 5-digit + display position
2nd line : 6-digit + test number
• Resistant to elevated temperatures
• Generally no display, activated with button
• Resetting of the current reading on the key day
Tamper-proof feature • In the event of heat accumulation changeover from 2-sensor to 1-sensor mode
• Registration of the time of fault or tampering with sensors and cables
Suppression of metering Temperature on radiator <23°C
Temperature when metering starts ∆tm > 4K (radiator sensor-ambient temperature sensor)
Temperature metering range • Compact meter: 0°C-128°C
• Remote sensor meter: 0°C-128°C
Temperature resolution • Better than 0.2 K
tmax • Compact meter: 90°C
• Remote sensor meter: 110°C
tmin 35°C
Scales • Unit scale
• Product scale
• Kk value
Calendar function • Reading stores on programmable key day at the end of the month
12 dates /year)
• Storage of readings for the year before previous
• Storage of readings for the previous year
Power supply 3.0 V lithium battery for 10-year service life + 1 year storage + 1 year
standby
Installation point Generally in the centre at 75% radiator height
Type of installation Screwing and welding
Switch2 Energy SolutionsHigh MillCullingworth