45847764 gsm timers document

76
Mobilink Confidential Property 1 TIMERS RF OPTIMIZATION ENGINEERING ACCESS NETWORK PMCL [MOBILINK]

Upload: nickolai-dydykin

Post on 02-Nov-2014

97 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: 45847764 GSM Timers Document

Mobilink Confidential Property 

1

    

TIMERS  

                   

RF OPTIMIZATION ENGINEERING ACCESS NETWORK 

PMCL [MOBILINK]     

Page 2: 45847764 GSM Timers Document

Mobilink Confidential Property 

2

FOREWORD    The document aims  to describe  various  timers  implemented  in  the GSM  network. While  reasonable  efforts  have  been made  to  assure  the accuracy of  this  document,  PMCL  assumes no  liability  resulting  from  any inaccuracies  or  omissions  in  this  document,  or  from  the  use  of  the information obtained herein.  

PMCL  reserves  the  right  to make changes  from  time  to  time  in  the content  of  this  document  and  hereof  with  no  obligation  to  notify  any person of revisions or changes.    

                     

  

Page 3: 45847764 GSM Timers Document

Mobilink Confidential Property 

3

TABLE OF CONTENTS  

1.0      Introduction  5 2.0      What does the manual cover?  5 3.0      Why the need to study timers?  5 4.0      Timer Categorization  6   4.1    Entity Based Categorization  6   4.2    Process Flow Based Categorization  6 

5.0      Breakdown   7 6.0      GSM Timers  9   6.1    Call Setup  10     6.1.1  T3120  12     6.1.2  T3126  13     6.1.3  T3101  14    6.1.4  T3230  15    6.1.5  T303  16    6.1.6  T310  17    6.1.7  T11  18    6.1.8  T10  19    6.1.9  T313  20    6.1.10  T3107  21    6.1.11  T1  22  6.2    Call Clearing  23    6.2.1  T13  23    6.2.2  T3111  24    6.2.3  T3109  25    6.2.4  T3110  26  6.3    Handover  27    6.3.1  T3103  28    6.3.2  T8  29    6.3.3  T7  30    6.3.4  TQHO  31    6.3.5  T3121  32  6.4    GPRS  32    6.4.1  T3182  33    6.4.2  T3164  34    6.4.3  T3198  35    6.4.4  T3180  36    6.4.5  T3190  37    6.4.6  T3192  38    6.4.7  T3200  39 

Page 4: 45847764 GSM Timers Document

Mobilink Confidential Property 

4

  6.4.8  T3162  40    6.4.9  T3168  41    6.4.10  T3170  42    6.4.11  T3172  43    6.4.12  T3176  44    6.4.13  T3188  45    6.4.14  T3322  46    6.4.15  T3380  47    6.4.16  T3385  48    6.4.17  T3386  49    6.4.18  T3390  50    6.4.19  T3395  51    6.4.20  T3158  52    6.4.21  T3166  53    6.4.22  T3169  54    6.4.23  T3174  55    6.4.24  T3182  56    6.4.25  T3178  57    6.4.26  T3184  58    6.4.27  T3191  59    6.4.28  T3193  60    6.4.29  T3195  61    6.4.30  T3310   62    6.4.31  T3312  63    6.4.32  T3314  64    6.4.33  T3321  65  6.5    Miscellaneous  66    6.5.1  T3210  66    6.5.2  T3128  67    6.5.3  T3211  68    6.5.4  T3212  69    6.5.5  T3220  70 

7.0      Compiled List  71   7.1    Motorola Timers List  71   7.2    Alcatel Timers List  73   7.3    Huawei Timers List  76 

     

Page 5: 45847764 GSM Timers Document

Mobilink Confidential Property 

5

1.0    INTRODUCTION  

Like any other wireless technology with a  limited pool of resources, GSM resource allocation and termination depends primarily on timers. The functionality  and  protocols  may  vary,  but  the  presence  of  timer  based signaling  and  resource  allocation  is  ubiquitous.  Timer  implementation  is present in each domain of the GSM system from MS to NSS end.  

2.0    WHAT DOES THIS MANUAL COVER?  

This document aims to describe all the major BSS timers  involved  in the GSM architecture. The timers are categorized into different subgroups, depending upon their parent entity and the process flow they are involved in. The document proceeds further by giving a detailed explanation of each timer along with its implementation in the PMCL network. 

 3.0    WHY THE NEED TO STUDY TIMERS?  

As already highlighted,  timer  implementation  is present  throughout the GSM architecture. Timers effect call setup procedures, handovers, call clearing,  data  usage  (GPRS),  VAS  facilities;  in  short,  everything  that  a customer might do to access and utilize the GSM network. Therefore, for a high  quality  network,  it  is  imperative  to  have  impeccable  timing.  Precise synchronization  and  timing  improves  call  signal  hand  over  performance between  base  stations;  and,  as  an  added  benefit,  reduces  customer complaints. GSM networks are dependent on strict synchronization of the base stations to facilitate call handovers. 

 Furthermore,  the  reason  for a deep understanding of  timers  is also 

re‐enforced by the multi vendor implementation present at all levels of the network.  Such  a  scenario  demands  all  database  discrepancies  to  be eliminated to ensure coherence and inter‐vendor compatibility. 

    

Page 6: 45847764 GSM Timers Document

Mobilink Confidential Property 

6

4.0    TIMER CATEGORIZATION 

 

4.1    ENTITY BASED CATEGORIZATION As highlighted earlier there are different ways of categorizing timers. One categorization  can  be  done  on  the  basis  of  entity  which  includes  the following categories: 

  

 

4.2   PROCESS FLOW BASED CATEGORIZATION A  further  classification of GSM  timers  can be done on  the basis of 

process  flows  involved  in  the  system.  These  include  the  following  basic categories: 

 

• Call Processing   Call Setup  Call Release 

• Handovers • GPRS • Miscellaneous  

  

Page 7: 45847764 GSM Timers Document

Mobilink Confidential Property 

7

5.0    BREAKDOWN [PHASE 1]  

The  task  of  documenting  the  GSM  timers  is  not  an  easy  paced procedure.  The  project  is  divided  into  two  phases.  The  first  phase comprised of the research for all the timers involved from MS to BSS as per the  international  GSM  standards.  In  the  second  phase,  vendor implementations of these timers were taken into consideration. A complete overview of all the timers involved in Phase 1 is as under:  

Timer  Call Flow  Vendor  Timer's Name  Category Default Value 

Range 

T3120  Call Setup 

Motorola  MS Timer MS Timer ‐  ‐Alcatel  MS Timer MS Timer ‐  ‐

Huawei  T3120  MS Timer Min is RACH T+2S; MAX 5 

Min is RACH T+2S ;MAX 5 

T3126  Call Setup 

Motorola  MS Timer MS Timer ‐  ‐Alcatel  MS Timer MS Timer ‐  ‐

Huawei  T3126  MS Timer Min is RACH T+2S MAX 5 

Min is RACH T+2S MAX 5 

T3122  Call Setup Motorola  wait_indication_parameter BTS none  0 to 255 secAlcatel  T3122 MS Timer ‐  0 to 255 secHuawei  T3122 Cell Timer 10 sec  0‐255  sec

T3101  Call Setup Motorola  rr_t3101 BTS 5 sec  0 to 1000 secAlcatel  T3101 BSC level 3 sec  0 to 25.5 secHuawei  T3101 Cell Timer 3 sec  0.5 to 60 sec

T3230  Call Setup Motorola  MS Timer MS Timer ‐  ‐Alcatel  MS Timer MS Timer ‐  ‐Huawei  T3230 MS Timer 15 sec  15 sec

T303  Call Setup Motorola  MS Timer MS Timer ‐  ‐Alcatel  MS Timer MS Timer ‐  ‐Huawei  T303 MSC Timer 20 sec  ‐

T310  Call Setup Motorola  MS Timer MS Timer ‐  ‐Alcatel  MS Timer MS Timer ‐  ‐Huawei  T310 MSC Timer 20 sec  ‐

T11  Call Setup Motorola  bssmap_t11 BTS 28 sec  0 to 1000 secAlcatel  T11 BSS 6 sec  0 to 19  secHuawei  T11 BSC Timer 8 sec  1 to 30 sec

T10  Call Setup Motorola  bssmap_t10 BTS 28 sec  0 to 1000 secAlcatel  bssMapT10 BSS 14 sec   ‐Huawei  T10 BSC Timer 7 sec  1 to 20 sec

T313  Call Setup Motorola  ‐ MSC timer ‐  ‐Alcatel  T313 MS Timer ‐   ‐Huawei  T313 MSC Timer 30 sec  30 sec

T8  Handover Motorola  bssmap_t8 BTS 28 sec  0 to 1000 secAlcatel  bssMapT8 BSS 14 sec  0 to 25.5 secHuawei  T8 Cell Timer 10 sec  0.5 to 60 sec

T3103  Handover  Motorola  rr_t3103 BTS 30 sec  0 to 1000 sec

Page 8: 45847764 GSM Timers Document

Mobilink Confidential Property 

8

Alcatel  T3103 BSS 16.5  sec  0 to 25.5 secHuawei  T3103 Cell Timer 10 sec  0.5 to 60 sec

T1  GPRS Motorola  bssmap_t1  BSC  30 sec 

0 to 1000000 msec 

Alcatel  bssMapT1 BSS  16 sec  10 to 25.5 secHuawei  T1 BSC Timer 30 sec  1 to 300  sec

T13  Call Clearing Motorola  bssmap_t13 BSC 40 sec  0 to 1000 secAlcatel  bssMapT13 BSS 15 sec  0 to 6553.5 secHuawei  T13 BSC Timer 150 sec  1 to 300 sec

T7  Handover Motorola  bssmap_t7 BSC 30 sec  0 to 1000 secAlcatel  bssMapT7 BSS 5 sec  0 to 20  secHuawei  T7 Cell Timer 10 sec  0.5 to 60 sec

TQHO  Handover Motorola  bssmap_tqho BSC 30 sec  0 to 1000 secAlcatel  T_QHO BSS 3 sec  0 to 20 secHuawei  TQHO BSC Timer 8 sec  1 to 30 sec

T3111  Call Clearing Motorola 

rr_t3111_sd BTS 1.5 sec  0 to 1000 secrr_t3111_tch BTS 1.5 sec  0 to 1000 sec

Alcatel  T3111 BSS 0.5 sec  0 to 2  secHuawei  T3111 Cell Timer 1 sec  0.5 to 60 sec

T3109  Call Clearing Motorola  rr_t3109 BTS 14.4 sec  0 to 1000 secAlcatel  T3109 BSS 12 sec  0 to 35 secHuawei  T3109 Cell Timer 27 sec  1‐35 sec

T3121  Handover Motorola  ‐ MSC Timer ‐  ‐Alcatel  T3121 BSS 14 sec  0 to 25.5 secHuawei  T3121 Cell Timer 10 sec  0.5 to 60

T3107  Call Setup Motorola  RRSM_T10 BTS 28 sec  0 to 1000 secAlcatel  T3107 BSS 14 sec  0 to 25.5 secHuawei  T3107 Cell Timer 10 sec  0.5 to 60 sec

T200  Configurational Motorola  lapd_t200_timer BTS 2.5 sec  1.4 to 5 secAlcatel  T200 BSS 0.3 sec  0.3 to 1 secHuawei  T200 (FACCH/F/H) Cell Timer 0.05 sec  1 to 0.255 sec

T9101  Call Clearing Motorola  ‐ ‐ ‐  ‐Alcatel  T9101 Network  10 sec  0 to 6553.5 secHuawei  SCCP_TREL(s) BSC Timer 15 sec  10 to 20 sec

T9104  Call Clearing 

Motorola  ‐ ‐ ‐  ‐Alcatel  T9104 BSS 2 sec  0 to 25.5 sec

Huawei TCLEARREQ(BSC) BSC Timer 5 sec  1 to 150 sec

TNT3(MSC) MSC Timer 6 sec  1 to 120 sec

T9108  Call Clearing Motorola  ‐ ‐ ‐  ‐Alcatel  T9108 Network  3 sec  0 to 6553.5 secHuawei  ‐ ‐ ‐  ‐

T3110  Call Clearing Motorola  MS Timer MS Timer ‐  ‐Alcatel  MS Timer MS Timer ‐  ‐Huawei  T3110 MS Timer 10 sec  0.5 to 60 sec

    

Page 9: 45847764 GSM Timers Document

Mobilink Confidential Property 

9

6.0    GSM TIMERS 

The  description  of  GSM  Timers  in  isolation  can  often  lead  to confusion  for  the  engineer.  To  ensure  uniformity  and  ease  of understanding, a format has been used to describe in detail each timer. The format is as given below.  

Timer Name  

This  field  will  include  the  name  of  the  Timer,  as  used  in  the international GSM standards.  

 

Category   

This  field  will  indicate  the  placement  of  the  timers  in  the  GSM network. For Example either a timer is used in Call Setup procedures or it is used to administer a Handover.  

 

Start Event  

This field will include the event which triggers the timer. 

  Stop Event  

 This field will include the event upon which, the timer stops.  

 

Expiry Event   

This is the event which takes place, once the timer has expired.    

Optional  field  include  the  values  used  by  the  vendors,  ranges  and default values.  

Page 10: 45847764 GSM Timers Document

Mobilink Confidential Property 

10

6.1   CALL PROCESSING  

This  section  deals  with  timers  that  essentially  make  up  the  call request and call setup procedure. A skim through the call flow shown below will help give the reader an  idea of the positioning of the timers and their importance. 

 Details  for  each  of  the  mentioned  timers  will  follow  along  with 

suitable information on them.  

  

      

 

Page 11: 45847764 GSM Timers Document

Mobilink Confidential Property 

11

 

Call Processing (Contd...)   

   

    

         

Page 12: 45847764 GSM Timers Document

Mobilink Confidential Property 

12

6.1.1   T3120  Category   This  timer  is  included  in  the Call Request procedure which starts with  the RACH request.   

Start Event  This timer starts when the RACH request is sent to the network.   

Stop Event   The timer stops once the RACH acknowledgment is received.   

Expiry Event  Once  the  timer  expires,  the  RACH  request  is  re‐Transmitted  on  the  air interface.    The default value for this timer is 10 seconds.   This  is  a MS  based  Timer  and  hence  vendor  implementation  data  is  not applicable.  

 

Page 13: 45847764 GSM Timers Document

Mobilink Confidential Property 

13

6.1.2  T3126   Category   This  timer  is  included  in  the Call Request procedure which starts with  the RACH request.   

Start Event  This  timer  starts when  the maximum  amount  of  Channel  requests  have been sent by the MS.   

Stop Event   The timer stops when immediate assignment message is received from the BSS.   

Expiry Event  Once  the  timer  expires,  the  procedure  for  immediate  assignment  is aborted.    The value of this timer depends on the setting of RACH re‐transmission.   This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is unavailable.  

 

Page 14: 45847764 GSM Timers Document

Mobilink Confidential Property 

14

6.1.3   T3101  Category   This  timer  is  included  in  the  Call  Setup  procedure which  starts with  the immediate assignment procedure.   

Start Event  This  timer  starts when  the  immediate assignment message  is  sent  to  the MS by the BSS entity.   

Stop Event   The timer stops when the Establish indication message is sent by the MS to the BSS entity.  

Expiry Event  Once the timer expires, the procedure for call setup is aborted.  The vendor based values for this timer are given below for reference.  

  Motorola   Alcatel   Huawei 

T3101  2 sec  3 sec  3 sec 

 

Page 15: 45847764 GSM Timers Document

Mobilink Confidential Property 

15

6.1.4  T3230  Category   This  timer  is  included  in  the  Call  Setup  procedure which  starts with  the immediate assignment procedure.   

Start Event  This timer starts when the CM service request is sent by the MS to the BSS entity   

Stop Event   The timer stops when the MS receives the message of CM Service request acknowledged. It is also stopped in case a CM service reject is received.  

Expiry Event  Once the timer expires, the release indication is provided to the BSS entity.   The default value for this timer is 15 seconds  This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is unavailable.  

  

Page 16: 45847764 GSM Timers Document

Mobilink Confidential Property 

16

6.1.5   T303  Category   This  timer  is  included  in  the  Call  Setup  procedure which  starts with  the immediate assignment procedure.   

Start Event  This timer starts when the UA frame for the SDCCH connection  is received by the MS.   

Stop Event   The timer is stopped when the CM service request is sent by the MS.  

Expiry Event  In case of an expiry event of this timer, the Call setup procedure is aborted.   The default value for this timer is 20 seconds  This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is unavailable.  

    

Page 17: 45847764 GSM Timers Document

Mobilink Confidential Property 

17

6.1.6   T310  

 Category   This  timer  is  included  in  the  Call  Setup  procedure which  starts with  the immediate assignment procedure.   

Start Event  This Timer starts when the MS receives Call proceeding message.   

Stop Event   The  timer  stops  once  the  Altering  procedure  begins  and  the  call  is established.  

Expiry Event  In case the timer expires and the altering procedure has not begun, the call setup procedure is aborted and No user Responding message is sent.    The default value for this timer is 20 seconds  This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is unavailable.   

  

Page 18: 45847764 GSM Timers Document

Mobilink Confidential Property 

18

6.1.7  T11  Category   This  timer  is  included  in  the  Call  Setup  procedure which  starts with  the immediate assignment procedure.   

Start Event  This  timer  starts when  an  assignment  resource  request  is queued by  the BSS entity.   

Stop Event   The timer  is stopped when the resource request  is allocated a resource by the BSS entity.   

Expiry Event  Once the timer expires, the resource request is rejected and the call setup procedure is aborted.  The vendor based values for this timer are given below for reference. 

 Note: If the value of T11 timer is kept more than the value of assign_successful timer [Motorola], this could lead to potential masking of Call Setup Blocking. CSSR  

  Motorola   Alcatel   Huawei 

T11  10 sec  6 sec  8 sec 

Page 19: 45847764 GSM Timers Document

Mobilink Confidential Property 

19

6.1.8  T10  Category   This  timer  is  included  in  the  Call  Setup  procedure which  starts with  the immediate assignment procedure.   

Start Event  This  timer  starts when  assignment  request  is  sent  to  the MS  by  the BSS entity.   

Stop Event   The timer is stopped when the assignment complete message is sent by the MS to the BSS entity.   

Expiry Event  Once  the  timer  expires,  the  assignment  request  is  released  and  the  call setup procedure is aborted.  The vendor based values for this timer are given below for reference  

  Motorola   Alcatel   Huawei 

T10  11 sec  14 sec  7 sec 

   Note: If the value of T10 timer is kept more than the value of assign_successful timer [Motorola],  this  could  lead  to  potential  masking  of  RF_Losses_SD  & Intra_cell_HO_Losses.  

 

Page 20: 45847764 GSM Timers Document

Mobilink Confidential Property 

20

6.1.9 T313  Category   This  timer  is  included  in  the  Call  Setup  procedure which  starts with  the immediate assignment procedure.   

Start Event  This  timer  starts  when  the  call  connect  message  is  sent  to  the  call originating mobile.  

Stop Event   The  timer  stops when  connect  acknowledge message  is  received  by  the network entity from the MS.   

Expiry Event  In case of an expiry even of this timer, the call setup procedure  is aborted and the call is released. 

Page 21: 45847764 GSM Timers Document

Mobilink Confidential Property 

21

6.1.10  T3107  Category   This  timer  is  included  in  the  Call  Setup  procedure which  starts with  the immediate assignment procedure.   

Start Event  This timer starts when the assignment command is sent by the BSS entity to the MS.  

Stop Event   The  timer  is stopped when  the Assignment complete message  is  received by BSS entity.  

Expiry Event  In case of an expiry event of this timer, an assignment failure command  is sent and the channels are released.   The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 

T3107  11 sec  14 sec  10 sec 

Page 22: 45847764 GSM Timers Document

Mobilink Confidential Property 

22

6.5.11 T1  Category   This  timer  is  included  in  the  Call  Setup  procedure which  starts with  the immediate assignment procedure.   

Start Event  This timer starts when a blocking message  is sent by the BSS entity to the MSC entity in case of non‐usable A interface timeslot.   

Stop Event   The timer is stopped when a Blocking acknowledgment message is received by the BSS entity.   

Expiry Event  On  first  expiry  of  the  timer,  the  BSS  entity  retransmits  the  Blocking message.  In  case  of  a  second  expiry,  the  channel  is  set  to  non‐usable without MSC acknowledgment.  The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 

T1  20 sec  16 sec  30 sec 

Page 23: 45847764 GSM Timers Document

Mobilink Confidential Property 

23

6.2   CALL CLEARING 

   Once  a  call  is  ended,  the  resources  that were  dedicated  to  it  now need  to  be  torn  down  so  that  they may  be  reused  by  other  users.  This process  is called call clearing. This section describes the timers used  in call clearing  

6.2.1 T13  Category   This timer is used in the Reset Procedure initiated by the MSC.  

Start Event  The timer starts when a Reset message is sent by the MSC to the BSS entity.  

Stop Event   The timer stops on when the MSC receives Reset Acknowledgement by the BSS entity.    

Expiry Event  In case of expiry event, the Reset acknowledgment is sent by the BSS to the MSC.  The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 

T13  40 sec  15 sec  150 sec 

  

Page 24: 45847764 GSM Timers Document

Mobilink Confidential Property 

24

6.2.2 T3111  Category   This timer is included in the Call release procedure which includes releasing of TCH channels  

Start Event  This timer starts with the reception of Release indication message from the BSS entity.  

Stop Event   The  timer  stops when  the  BSS  entity  sends  the message  for  RF  channel release to the respective BTS.   

Expiry Event  The  expiry  of  this  timer  causes  the  forced  channel  release  procedure  to start and the channel is released from all ends of the network.   The vendor based values for this timer are given below for reference  

  Motorola   Alcatel   Huawei 

T3111  1.5 sec  0.5  1.5        

Page 25: 45847764 GSM Timers Document

Mobilink Confidential Property 

25

6.2.3 T3109  Category   This timer is included in the Call release procedure which includes releasing of TCH channels  

Start Event  This  timer  starts  when  the  channel  release message  is  sent  by  the  BSS entity to the subsequent BTS.   

Stop Event   The  timer  is  stopped when  the  release  indication message  is  received by the BSS entity.  

Expiry Event  In case of an expiry event of this timer, the channels are released and call procedure is aborted.   The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei T3109  15 sec  12 sec  15 sec  

  

Page 26: 45847764 GSM Timers Document

Mobilink Confidential Property 

26

6.2.4 T3110  Category   This timer is included in the Call release procedure which includes releasing of TCH channels  

Start Event  This timer starts when the MS receives the Channel release message from the BSS entity.  

Stop Event   The  timer  stops  once  the MS  receives  a  layer  ‐2‐message  from  the  BSS entity for channel release.  

Expiry Event  In case the timer expires, the normal channel release continues till the call is released.   The default value for this timer is 10 seconds  This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is unavailable.  

Page 27: 45847764 GSM Timers Document

Mobilink Confidential Property 

27

6.3   HANDOVER 

This section deals with timers that essentially make up the handover procedure. Like call processing, a ladder diagram for handover is also given below for the ease of the reader. 

 Details  for  each  of  the  mentioned  timers  will  follow  along  with 

suitable information on them. 

       

Page 28: 45847764 GSM Timers Document

Mobilink Confidential Property 

28

6.3.1  T3103  Category   This timer is used in the Handover Procedure.  

Start Event  The timer starts when the initiate Handover command is sent to the BTS by the BSC.   

Stop Event   The Timer is stopped when handover complete message is received by the BSS entity.   

Expiry Event  In  case  the  timer  expires,  the  handover  procedure  is  aborted  and  the Handover attempt is termed as unsuccessful.   The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 

T3103  30 sec  16.5 sec  30 sec 

      

Page 29: 45847764 GSM Timers Document

Mobilink Confidential Property 

29

6.3.2  T8  Category   This timer is used in the Handover Procedure.  

Start Event  The timer starts when the Handover command is sent to the MS via the BSS entity.  

Stop Event   The Timer is stopped when handover complete message is received by the BSS entity.   

Expiry Event  In  case  the  timer  expires,  the  handover  procedure  is  aborted  and  the Handover attempt is termed as unsuccessful.   The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 

T8  28 sec  14 sec  28 sec  Note: If the value of T8 timer is set greater than the value of T3103, this could lead to potential  masking  of  Out_Intra_BSS_HO_LostMS  in  Intra  BSS  HOs  & Out_Inter_BSS_HO_Return, Out_Inter_BSS_Equip_Fail in Inter BSS HOs. 

Page 30: 45847764 GSM Timers Document

Mobilink Confidential Property 

30

 6.3.3 T7  

 Category   This timer is used in the Handover Procedure.  

Start Event  The timer starts when a Handover Request message is sent to the MSC for an external BSC handover.  

Stop Event   The Timer  is stopped when handover response message  is received by the BSS entity.   

Expiry Event  In  case  the  timer  expires,  the  handover  procedure  is  aborted  and  the Handover attempt is termed as unsuccessful.   The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 

T7  10 sec  5 sec  10 sec 

Page 31: 45847764 GSM Timers Document

Mobilink Confidential Property 

31

6.3.4 TQHO  Category   This timer defines the maximum Queuing time for a Handover request.  

Start Event  The  timer starts when  the BSS places a Handover  request  in  the  resource queue for allocation.  

Stop Event   The timer  is stopped when the Handover request  is allocated the required resource by the BSS entity.  

Expiry Event  In case of an expiry event of  this timer,  the handover request  is removed from the queue and the handover procedure is aborted.  The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 

TQHO  30 sec  5 sec  8 sec 

  

Page 32: 45847764 GSM Timers Document

Mobilink Confidential Property 

32

6.3.5 T3121  Category   This timer IS related with inter BSC and 2G/3G handovers.  

Start Event  The  timer  is  started  when  a  request  is  sent  for  an  inter‐BSC  or  2G/3G handover.   

Stop Event   The  timer  is  stopped when a Handover  complete message  is  received by the BSS entity.  

Expiry Event  In  case  of  an  expiry  event  of  this  timer,  Clear  request  is  sent  and  the handover procedure is aborted.  The vendor based values for this timer are given below for reference 

  Motorola   Alcatel   Huawei 

TQHO  N‐A  14 sec  10 sec 

Page 33: 45847764 GSM Timers Document

Mobilink Confidential Property 

33

6.4   GPRS TIMERS   

6.4.1   T3182  Category   This  is an MS Based Timer and  it  is concerned with  the RLC Window and stalling of TBF.    

Start Event  If the RLC transmit window is filled with transmitted blocks and any of them is unacknowledged, then the TBF window stalls and no more blocks can be set. At this time, T3182 is started.   

Stop Event   The  timer  stops once  the  acknowledgment  for  all  the  transmitted  blocks has been received.   

Expiry Event  If the timer expires, then another timer N3102  is decremented. The Radio resources are released and the Mobile station tires to reestablish  the TBF with the same cell through packet channel request.   

Page 34: 45847764 GSM Timers Document

Mobilink Confidential Property 

34

6.4.2   T3164  Category   This is an MS based timer which is concerned the access procedures during GPRS connections.  

Start Event  MS  access  the  network  for  a  GPRS  connection  through  the  Packet  data request. The BTS send the packet uplink assignment message through the USF access. The timer will start on reception of this assignment message.   

Stop Event   The timer will stop once the USF uplink access has also been granted on the downlink.   

Expiry Event  If the timer expires, and the access has not been granted on the downlink, then the radio resources will be released and the Mobile station will repeat the whole procedure from the packet data request message.              

Page 35: 45847764 GSM Timers Document

Mobilink Confidential Property 

35

6.4.3  T3198  Category   This  is  an MS  based  timer which  is  concerned  the  acknowledgement  of transmitted RLC Blocks  

Start Event  When  a  RLC  block  is  transmitted  by  the Mobile  station,  Timer  T3198  is started.  

Stop Event   The  timer  is  stopped when  the  acknowledgment  of  the  transmitted  RLC block is received by the Mobile station.   

Expiry Event  If  the  timer  expires with no  acknowledgment  for  the  transmitted blocks, the RLC blocks is tagged as NACK in the MS.    

Page 36: 45847764 GSM Timers Document

Mobilink Confidential Property 

36

6.4.4   T3180  Category   This timer is related with the dynamic allocation of Uplink TBF in the GPRS connection.  

Start Event  This timer is started during the dynamic allocation of the Uplink TBF. When the last block is sent as permitted by the USF granularity, the Timer 3180 is started with this transmission.  

Stop Event   When the USF is received in the downlink by the MS, this timer is stopped.  

Expiry Event  In  case  the  timer  expires,  the  MS  abandons  the  TBF  and  the  access procedure is repeated with the same cell. 

Page 37: 45847764 GSM Timers Document

Mobilink Confidential Property 

37

6.4.5   T3190  Category   This timer is related with the downlink assignment of Packet Data.  

Start Event  The timer is started when the Mobile station receives the downlink packet data assignment from the BSS entity.   

Stop Event   The timer  is stopped when the Mobile station receives the downlink block containing the allocated TFI.   

Expiry Event  In case  the  timer expires,  the mobile  station  releases  the  radio  resources and aborts the TBF connection. In addition to this, the Mobile station starts monitoring the Common Control Packet channel. 

Page 38: 45847764 GSM Timers Document

Mobilink Confidential Property 

38

6.4.6  T3192  Category   This timer is concerned with the release of Packet Data Channel  

Start Event  The timer is started when the last block of downlink TBF is received.   

Stop Event   If a message for forced release of Packet Data channel is received, the timer is stopped.   

Expiry Event  When  the  timer expires,  the  radio  resources are  released and  the packet data session comes to an end. It is to be noted that the value of this timer is smaller than T3193,  in order to make  it sure that the TFI of this MS  is not allocated to any other MS in the mean time. 

Page 39: 45847764 GSM Timers Document

Mobilink Confidential Property 

39

6.4.7   T3200  Category   This Timer is related with the partitioned transmission of the RLC Blocks.   

Start Event  In the partitioned transmission of RLC blocks, the RLC frames are dived into segments  with  each  segment  having  its  own  RTI  (Radio  Transaction Indicator). If the one of the segment is not received with its subsequent RTI, timer T3200 is started.   

Stop Event   The  timer  is  stopped when  the  correct  segment with  the  following RTI  is received.   

Expiry Event  In case the time expires and the correct RTI has not been received, then the whole control block is rejected as a one or more segments are missing. 

Page 40: 45847764 GSM Timers Document

Mobilink Confidential Property 

40

6.4.8  T3162  Category   This  timer  is concerned with  the queuing procedure employed during  the packet data access.   

Start Event  The  timer  is started when  the MS  receives  the Packet Queue Notification from  the  BSS  entity.  This  message  is  in  response  to  the  Packet  access message.   

Stop Event   The  timer  is  stopped  in  case  of  a  packet  assignment message  or  packet accesses reject method.   

Expiry Event  If the timer expires without any assignment or reject message, the access procedure  is  aborted  and  the mobile monitors  the  Packet  data  common control channel. 

Page 41: 45847764 GSM Timers Document

Mobilink Confidential Property 

41

6.4.9  T3168  Category   This  timer  is concerned with acquisition of TBF  resources during a Packet Data session.   

Start Event  This timer starts when a packet data request  is sent by the Mobile station for more data resources during a TBF session.   

Stop Event   The Timer is stopped when the assignment message is received for the new uplink resource of TBF.  

Expiry Event  In case the timer expires, the request of Packet Data resources is resent by the Mobile Station. 

Page 42: 45847764 GSM Timers Document

Mobilink Confidential Property 

42

6.4.10   T3170  Category   This timer determines the time span for which the Mobile station will wait after sending the allowed number of Packet Data requests.  

Start Event  The timer starts when the  last of the allowed Packet Data Request  is sent by the Mobile station to the BSS entity.   

Stop Event   The timer is stopped when the Mobile station receives the uplink resources assignment message from the BSS entity.   

Expiry Event  In case  the  timer expires,  the access procedure  is aborted and  the upper layers are informed as well.                 

Page 43: 45847764 GSM Timers Document

Mobilink Confidential Property 

43

6.4.11  T3172  Category   This  Timer  is  concerned with  the wait  time  used  for  re‐transmitting  the access request for Packet Data.   

Start Event  The  timer  begins  with  the  Packet  Assignment  Reject  method  and  this message also contains the amount of time, the timer has to remain active.   

Stop Event   The  timer  is stopped when  the Packet Assignment message  is  received  in response to the access request.   

Expiry Event  In case  the  timer expires, a  request of Packet Data  resources  is  resent by the Mobile Station.                

Page 44: 45847764 GSM Timers Document

Mobilink Confidential Property 

44

6.4.12   T3176  Category   This  timer  is  concerned with  the  signaling  for  cell  change  failure  during packet data session.  

Start Event  The timer is started when the first message for cell change failure is sent to the BSS entity.   

Stop Event   The timer is stopped if a successful cell change occurs and the confirmation message is sent to the Mobile station. .   

Expiry Event  In case the timer expires, the signaling for the failed cell changes is stopped and the Mobile station returns to normal operation.       

Page 45: 45847764 GSM Timers Document

Mobilink Confidential Property 

45

6.4.13   T3188  Category   This timer is used for the fixed allocation of uplink TBF.  

Start Event  The timer is started when the Mobile station sends a request to BSS entity regarding access for the fixed uplink TBF. .   

Stop Event   The  timer  is  stopped  once  the  Mobile  station  receives  the  assignment message for the uplink resource.   

Expiry Event  In case the timer expires, the request for the resources is re‐sent. 

Page 46: 45847764 GSM Timers Document

Mobilink Confidential Property 

46

6.4.14  T3322  Category   This timer is involved in the Detach process in the Packet Data connection.  

Start Event  The timer is started when the detach request is sent by the Mobile station to the BSS entity.  

Stop Event   The  timer  is stopped when  the Mobile station receives  the Detach accept message from the BSS entity.   

Expiry Event  In  case  the  timer  expires,  the  detach  request  is  resent  by  the  Mobile station.   

Page 47: 45847764 GSM Timers Document

Mobilink Confidential Property 

47

6.4.15   T3380  Category   This timer is used in the PDP Context activation procedure.   

Start Event  The  timer  is  started when  the Mobile  station  sends  the  request  for  PDP context activation.   

Stop Event   The timer  is stopped when the BTS entity sends the confirmation message for the attach procedure.   

Expiry Event  In  case  the  timer  expires,  the  request  for  PDP  context  is  resent  by  the Mobile station.  

Page 48: 45847764 GSM Timers Document

Mobilink Confidential Property 

48

6.4.16   T3385  Category   This timer is used in the PDP Context activation procedure.   

Start Event  The timer  is started when the network sends the request for start of data session to the SGSN.  

Stop Event   The timer is stopped when the SGSN entity sends the confirmation message for the start of data connection.   

Expiry Event  In  case  the  timer  expires,  the  request  for  data  session  is  resent  by  the network.  

Page 49: 45847764 GSM Timers Document

Mobilink Confidential Property 

49

6.4.17   T3386  Category   This timer is used in the PDP Context modification procedure.   

Start Event  The timer  is started when the network sends the request for modification of PDP context to the MS.   

Stop Event   The  timer  is  stopped  when  the  network  receives  the  response  of  the modification message.  

Expiry Event  In case  the  timer expires,  the  request  for modification  for PDP Context  is resent by the network.  

Page 50: 45847764 GSM Timers Document

Mobilink Confidential Property 

50

6.4.18   T3390  Category   This timer is used in the PDP Context deactivation procedure.   

Start Event  The timer is started when the MS sends the request for deactivation of PDP context to the network.   

Stop Event   The  timer  is  stopped  when  the  MS  receives  the  Deactivation  accept message from the network.   

Expiry Event  In case  the  timer expires,  the  request  for deactivation  for PDP Context  is resent by the MS.  

Page 51: 45847764 GSM Timers Document

Mobilink Confidential Property 

51

6.4.19   T3395  Category   This timer is used in the PDP Context deactivation procedure.   

Start Event  The  timer  is  started when  the GPRS  Sub  network  sends  the  request  for deactivation of PDP context to the network.   

Stop Event   The timer is stopped when the GPRS Sub network receives the Deactivation accept message from the network.   

Expiry Event  In case  the  timer expires,  the  request  for deactivation  for PDP Context  is resent by the GPRS sub network.  

Page 52: 45847764 GSM Timers Document

Mobilink Confidential Property 

52

6.4.20   T3158  Category   This timer relates to Period between measurement reports. The Measurement reports may be made in packet idle mode or packet transfer mode, the timer being set by NC_REPORTING_PERIOD_I (packet idle) or NC_REPORTING_PERIOD_T (transfer).   

Start Event  Sending of previous measurement report.  

Stop Event   None  

Expiry Event  Next measurement report sent.               

Page 53: 45847764 GSM Timers Document

Mobilink Confidential Property 

53

6.4.21   T3166  Category   This timer is the One‐phase access contention timer   

Start Event  When the first RLC/MAC block is transmitted   

Stop Event   when a packet uplink ack/nack returning TLLI is received  

Expiry Event  On expiry, the mobile station must stop transmitting and  disconnect from the radio resources. A contention failure or other failure has occurred.               

Page 54: 45847764 GSM Timers Document

Mobilink Confidential Property 

54

6.4.22  T3169  Category   Response to USF tolerance timer  

Start Event  N3101 reaches its allowed maximum count, N3101_MAX.  

Stop Event   None  

Expiry Event  On expiring, the USF is released (which means it can be reassigned to another mobile station).                  

Page 55: 45847764 GSM Timers Document

Mobilink Confidential Property 

55

6.4.23   T3174  Category   Handover (cell change order) failure timer  

Start Event  When the GPRS sub‐network is in command of cell selection, it may tell the mobile station to change to another cell with packet cell change order. This command starts T3174 and the mobile station changes physical channels, sending a packet channel request to the new cell.  

Stop Event   When a packet uplink assignment is received from the new cell.  

Expiry Event  Handover or cell change has failed and T3176 starts. 

Page 56: 45847764 GSM Timers Document

Mobilink Confidential Property 

56

6.4.24   T3182  Category   Window stall timeout for dynamic allocation  

Start Event  When the RLC transmit window k is filled with transmitted RLC/MAC blocks, any one of which is unacknowledged, then the TBF window ‘stalls’ and no more blocks can be sent. T3182 is then started.  

Stop Event   Packet uplink acknowledge reception from the GPRS sub‐network, allowing the window to be advanced and transmissions to be resumed.  

Expiry Event  N3102 is decremented (by the amount PAN_DEC sent in packet system information), disconnects from the radio resources and attempts to re‐establish the TBF in the same cell with packet channel request.     

Page 57: 45847764 GSM Timers Document

Mobilink Confidential Property 

57

6.4.25   T3178  Category   Packet idle mode extended measurement report period  The value of this timer is contained in the idle mode extended measurement reports command contained in PSI5 or PCCCH. The mobile station will report measurements with this periodicity.  

Start Event  N/A  

Stop Event   N/A  

Expiry Event  N/A    

Page 58: 45847764 GSM Timers Document

Mobilink Confidential Property 

58

6.4.26   T3184  Category   Fixed allocation packet uplink ack/nack tolerance timer  

Start Event  Receipt of packet uplink ack/nack.   

Stop Event   Receipt of the next packet uplink ack/nack.   

Expiry Event  Mobile station releases the TBF and radio resources.    

Page 59: 45847764 GSM Timers Document

Mobilink Confidential Property 

59

6.4.27   T3191  Category   Response to final data block tolerance timer  

Start Event  Transmission of the final RLC data block in a downlink TBF  

Stop Event   Receipt of packet downlink ack/nack or packet control ack  

Expiry Event  TFI and other resources are released.    

Page 60: 45847764 GSM Timers Document

Mobilink Confidential Property 

60

6.4.28   T3193  Category   Uplink RLC release timer. This is the network counterpart of T3192. This timer must be longer than T3192.   

Start Event  (See T3192)  

Stop Event   (See T3192)  

Expiry Event  (See T3192)   

Page 61: 45847764 GSM Timers Document

Mobilink Confidential Property 

61

6.4.29   T3195  

Category   Linked to TBF and TFI  

Start Event  T3195 starts when N3105 reaches to maximum value  

Stop Event   N/A  

Expiry Event  The network releases TFI resource   

Page 62: 45847764 GSM Timers Document

Mobilink Confidential Property 

62

6.4.30  T3310  Category   Attach request timer  

Start Event  When attach request is sent.  

Stop Event   Attach accept is received.  

Expiry Event  Attach request message is resent.    

Page 63: 45847764 GSM Timers Document

Mobilink Confidential Property 

63

6.4.31   T3312  Category   Periodic routing area update  Determines when the mobile station GMM function will perform an automatic RA update (irrespective of whether the RA has changed).   

Start Event  N/A  

Stop Event   N/A  

Expiry Event  N/A   

Page 64: 45847764 GSM Timers Document

Mobilink Confidential Property 

64

6.4.32   T3314  Category   Ready timer  This timer specifies the maximum time that the mobile station is allowed to remain in GMM ready condition without an LLC PDU transfer with the GPRS sub‐network.   

Start Event  Sending of an LLC PDU to the GPRS sub‐network  

Stop Event   Sending of an LLC PDU to the GPRS sub‐network  

Expiry Event  Mobile station is forced to GMM standby.    

Page 65: 45847764 GSM Timers Document

Mobilink Confidential Property 

65

6.4.33   T3321  Category   GPRS sub‐network detach timer  

Start Event  Sending of detach request  

Stop Event   Reception of detach accept.  

Expiry Event  Mobile station resends the detach request 

Page 66: 45847764 GSM Timers Document

Mobilink Confidential Property 

66

6.5   MISCELLANEOUS   

6.5.1 T3128  Category   This  timer  is  related  with  the  access  procedure  of  Uplink  investigation process.   

Start Event  The  timer  starts when  the  uplink  busy message  is  sent  to  the MS  upon receiving access request for uplink investigation.  

Stop Event   The timer is stopped when Uplink free message is sent to the MS.  

Expiry Event  In case of an expiry event of this timer, the Uplink  investigation process  is aborted.   The default value for this timer is 1 second. This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is unavailable.     

Page 67: 45847764 GSM Timers Document

Mobilink Confidential Property 

67

6.5.2 T3210  Category   This timer is related with the access procedure of Location Update.  

Start Event  The timer starts when the MS sends the location update request to the BSS entity.   

Stop Event   The timer  is stopped when the Location_update_accept or reject message is received by the MS entity. This  timer  is also stopped  in case of a  lower layer failure.  

Expiry Event  In case of an expiry event of this timer, the BSS timer T3211 is started.  The default value for this timer is 20 seconds. This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is unavailable.    

Page 68: 45847764 GSM Timers Document

Mobilink Confidential Property 

68

6.5.3 T3211  Category   This  timer  is  related  with  the  access  procedure  of  location  update procedure.  

Start Event  This  timer  starts when  location_update_reject  is  received with  the  cause value indicating network failure.  

Stop Event   The Timer  is stopped when the  location update takes place or cell  for the particular MS is changed.  

Expiry Event  In case this timer expires, the request  for  location update  is again sent to the BSS entity.   The default value for this timer is 15 seconds.

   

Page 69: 45847764 GSM Timers Document

Mobilink Confidential Property 

69

6.5.4 T3212  Category   This timer is related with the termination of MM signaling.  

Start Event  This timer starts with the termination of MM signaling.   

Stop Event   The timer stops when the message for the initiation of MM signaling is sent to the MS by the BSS entity.   

Expiry Event  In case the timer expires, a periodic request is sent for the LU update.   The default value for this timer is 60 seconds. This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is unavailable.    

Page 70: 45847764 GSM Timers Document

Mobilink Confidential Property 

70

6.5.5 T3220  Category   This timer is related with the IMSI detach procedure.  

Start Event  The  timer  starts when  the MS  sends an  IMSI detach message  to  the BTS entity.   

Stop Event   The timer is stopped when the MS is removed from the MM sub‐layer.   

Expiry Event  In case the timer expires, the MS enters the Null period and request is sent for the status to be updated.   The default value for this timer is 5 seconds. This  is  a  MS  based  Timer  and  hence  vendor  implementation  data  is unavailable.  

Page 71: 45847764 GSM Timers Document

Mobilink Confidential Property 

71

7.0    VENDOR BASED COMPILED LISTS  

7.1    MOTOROLA TIMERS 

Timers T_hand_rqd   T3230 T_HAND_RQD   T3240 T_SDCCH_HO_ALLOWED  T4 t_stat_info   T4 (ITU)  T1   T4_TIMER  T1 (ITU)  T4_TIMER (Lb interface)  T1_TIMER   T4_TIMER_ID (Lb interface)  T1_TIMER (Lb interface)   T5 T1_TIMER_ID (Lb interface)   T5 (ITU)  T12   T5_TIMER  T12_TIMER  T5_TIMER (Lb interface)  T12_TIMER (Lb interface)   T5_TIMER_ID (Lb interface)  T13   T6 T13_TIMER  T6 (ITU)  T13_TIMER (Lb interface)   T6_TIMER_ID (Lb interface)  T14   T7  T14_TIMER  T7 (ITU)  T14_TIMER (Lb interface)   T7_EXP‐MSG_TYPE  T17   T7_TIMER_ID (Lb interface)  T17_TIMER   TCH assignment‐successful  T17_TIMER (Lb interface)   TCH assignment‐unsuccessful  T2  TCONN_EST  T2 (ITU)   Tqho T2_TIMER   TREL 

T2_TIMER (Lb interface)   bssgp_t1_timer  T2_TIMER_ID (Lb interface)   bssgp_t2_timer  T22   bssgp_t5_timer  T22_TIMER   bssmap_t1  T22_TIMER (Lb interface)   bssmap_t10  T23   bssmap_t11  T23_TIMER   bssmap_t13  T23_TIMER (Lb interface)   bssmap_t19  T3  bssmap_t20 T3 (ITU)   bssmap_t4  T3_TIMER_ID (Lb interface)   bssmap_t7  T3101   bssmap_t8  T3103   bssmap_tqho  T3105   bounce_protect_cong_tmr  T3109   bounce_protect_qual_tmr  T3111   bts_p_con_timer T3122   CLM_T1  T3210   CLM_T13  T3212   CLM_T19  T3220  CLM_T20  

Page 72: 45847764 GSM Timers Document

Mobilink Confidential Property 

72

Timer 

CLM_T4   rr_t3111  hop_count_timer  rr_t3111_sd  lb_int_ss7_l2_t1   rr_t3111_tch  lb_int_ss7_l2_t2   rr_t3212  lb_int_ss7_l2_t3   RRSM_AUDIT_TIMER  lb_int_ss7_l2_t4   RRSM_T10  lb_int_ss7_l2_t5   RRSM_T11  lb_int_ss7_l2_t6   RRSM_T8  lb_int_ss7_l2_t7   ss7_l2_t1  lb_int_ss7_l3_t1   ss7_l2_t2  lb_int_ss7_l3_t12  ss7_l2_t3  lb_int_ss7_l3_t13  ss7_l2_t4  lb_int_ss7_l3_t14  ss7_l2_t5  lb_int_ss7_l3_t17  ss7_l2_t6  lb_int_ss7_l3_t2   ss7_l2_t7  lb_int_ss7_l3_t22   ss7_l3_t1  lb_int_ss7_l3_t23   ss7_l3_t12  lb_int_ss7_l3_t4   ss7_l3_t13  lb_int_ss7_l3_t5   ss7_l3_t14  lb_int_ss7_slt_t1   ss7_l3_t17  not aligned timer   ss7_l3_t2  ns_alive_timer   ss7_l3_t22  ns_block_timer   ss7_l3_t23  ns_reset_period   ss7_l3_t4  ns_reset_timer   ss7_l3_t5  ns_test_timer   wait for clear command from the BSS‐based SMLC timer  penalty_time   wait for SCCP release complete timer  PENALTY_TIME   wait for SCCP released message from SMLC timer  PERF_LOC_TIMER   wait_for_reselection  rr_ny1_rep   wait_indication_parameters  rr_t3101  waiting for changeback acknowledgement (rst attempt) timer  rr_t3103   waiting for changeback acknowledgement (second attempt) timer  rr_t3105   waiting for changeover acknowledgement timer  rr_t3109   waiting for force uninhibit timer to 3‐62, 3‐210, 3‐212, 3‐214, 3‐10  waiting for inhibition acknowledgement timer  rr_t3110  add_access_class rf_chan_rel_ack  sccp_tconn_est retry_cand_period  radiochanrel exrtrycandprd  sccp_released validcandperiod  assign_successful radio_link_timeout  bsc_audit link_fail  bsc_audit_response linkabouttofail  clear_command channel_act  clear_cmd_ext_ho channel_teardown  circuit_reset_ack cipher_comp_ms  ciphering_successful ho_complete  ext_ho_allocation mode_modify  ho_allocation modeRRModifyAck  ho_request register_exp  ho_successful 

Page 73: 45847764 GSM Timers Document

Mobilink Confidential Property 

73

7.2    ALCATEL TIMERS  

Timer   Entity  Timer  Entity T(conn est)  BSC  T_GSL_ACK (BSC)  BSC T(iar)  BSC  T_HO_REQD_LOST  BSC T(sst)  BSC  T_INHIBIT_CPT  BSC T_ALLOC_BTS  BSC  T_LB_OV  BSC T_AVG_T (MFS)  MFS  T_LCS_RESTART (BSC)  BSC T_BA_CHANGE  MFS  T_Location  BSC T_BTS_RLS_CNF  BSC  T_MAX_FOR_MS_SYNCHRO  MFS T_CBC_READY  BSC  T_MAX_STREAMING_BUFFERING  MFS T(ias)  BSC  T_MS_CELL_REJ  BSC T_ACK_WAIT  MFS  T_NC_PING_PONG  MFS T_AUTOCLEANING_MEAS_REP  BSC  T_NC2_LOAD_RANKING  MFS T_AVG_W (BSC)  BSC  T_One_Block  MFS T_BIND_CNF  BSC  T_COUNT_I  BSC T_BURST  BSC  T_DELAY_GSL  BSC T_CFI_TR  BTS  T_DELAYED_DL_TBF_POL_INITIAL  MFS T(rel)  BSC  T_dl_assign_ccch  MFS T_ACK_WAIT_DRX_PCCCH  MFS  T_DSP_LOAD_REPORT  MFS T_AVG_T (BSC)  BSC  T_EXTENDED_UL_TBF_POL  MFS T_AVG_W(MFS)  MFS  T_flow_ctrl_cell  MFS T_BTS_EST_CNF  BSC  T_GCH_INACTIVITY_LAST  MFS T_CANDIDATE_TBF_REALLOC  MFS  T_GSL_ACK (MFS)  MFS T_CHANGE_RLC_MODE  MFS  T_i  BSC T_CONFIG_TBF  MFS  T_INITIAL_PDCH  MFS T_DELAY  BSC  T_LCS_Delay_Tolerant  MFS T_DELAY_PAGING_EXT  MFS  T_LCS_RESTART (MFS)  MFS T_Delayed_DL_TBF_Pol_UL  MFS  T_Location_Longer  BSC T_DL_EGPRS_MeasReport  MFS  T_MAX_FOR_TBF_SCHEDULING  MFS T_DTM_ASSIGN  MFS  T_MIN_POLL  MFS T_FAST_DL_margin  MFS  T_MS_CONTEXT_FLUSH_PERSISTENCE  MFS T_flow_ctrl_ms  MFS  T_NC_REJ_CELL  MFS T_GPRS_Resume  BSC  T_NETWORK_RESPONSE_TIME  MFS T_HCP  BSC  T_OVL_MSC  BSC T_IA  BSC  T_PAG_CS (BSC)  BSC T_INTRF_L3  BSC  T_PAG_PS (MFS)  MFS T_LCS_Low_Delay  MFS  T_PDA  BSC T_Loc_abort  BSC  T_PUA  BSC T_MAX_EXTENDED_UL  MFS  T_RECOVERY  BSC T_MAX_RETRANS_DL  MFS  T_REPETITION_UPLINK_FREE  BSC T_MPDCH_EST_PROC (BSC)  BSC  T_RESET_COUNTER  BTS T_MS_Context_Lifetime  MFS  T_RMS_BSC_RESTART  BSC T_NC_RXQUAL_VALID  MFS  T_RRLP_Low_Delay  MFS T_NOTIF_RESPONSE_DELAY  BSC  T_SHARED_DTM_INFO (BSC)  BSC T_CONNECT  BSC  T_SMSCB_RESP  BSC T_delay_gch  MFS  T_SYNC  BTS T_DELAYED_DL_TBF_POL  MFS  T_ta  BTS T_DELAYED_FINAL_PUAN  MFS  T_TFO  BSC T_DL_GPRS_MeasReport  MFS  T_ul_assign_pccch  MFS T_DYN_SDCCH_HOLD  BSC  T_WAIT_CS_PROC  MFS 

Page 74: 45847764 GSM Timers Document

Mobilink Confidential Property 

74

Timer   Entity  Timer  Entity 

T_FILTER  BSC  T_WAIT_PMR_MARGIN  MFS T_GCH_INACTIVITY  MFS  T1_0858  BSC T11  BSC  T3168 (BSC)  BSC T_PAG_CS (MFS)  MFS  T3180  MFS T_PAGING_EXT  MFS  T3191  MFS T_PSCD_SCHEDULE_ACK  MFS  T3208n  MFS T_qho  BSC  T391  MFS T_release  TC  T7  BSC T_REROUTING_REQUEST_GUARD  MFS  T17  BSC T_RMS_BSC  BSC  T19  BSC T_RMS_BTS  BSC  T200 (BSC)  BSC T_SAGI_GUARD  MFS  T200_GSL (BSC)  BSC T_SHARED_DTM_INFO (MFS)  MFS  T200_S3  BTS T_STOP_FR_EMISSION  MFS  T200_TF  BTS T_SYNCd  BTS  T203 (BSC)  BSC T_TBF_ACTIV  MFS  T203_GSL (MFS)  MFS T_ul_access_max  MFS  T3105_D  BSC T_UL_CONGESTION  MFS  T3105_F_HR  BSC T_WAIT_DTM  MFS  T3106_D_STOP  BSC T_WAIT_UPLINK_ACCESS  BSC  T3107  BSC T1_long  BSC  T3115  BSC T11_FORCED  BSC  T3148n  BSC T_PAG_PS (BSC)  BSC  T3168 (MFS)  MFS T_PAGING_REORG  MFS  T3182n  MFS T_PSI_PACCH  MFS  T3192 (BSC)  BSC T_RCR_ACK  BSC  T3212(BSC)  BSC T_REPETITION_CHANNEL_RELEASE  BSC  T4  BSC T_RESEL  MFS  T8  BSC T_RMS_BSC_RECONF  BSC  T18  BSC T_RRLP_Delay_Tolerant  MFS  T2_0858  BSC T_SDCCH_PC  BSC  T200_D  BTS T_SMSCB_READY  BTS  T200_GSL (MFS)  MFS T_SUP  BTS  T200_SD  BTS T_SYNCu  BTS  T200_TH  BTS T_TBF_BCK_REL  MFS  T203 (BTS)  BTS T_ul_assign_ccch  MFS  T3101  BSC T_USF_Scheduling_AGCH  MFS  T3105_D_STOP  BSC T_WAIT_FLUSH  MFS  T3105_F_STOP  BSC T_WAIT_UPLINK_REQUEST_ACK  BSC  T3106_F  BSC T1_short  BSC  T3109  BSC T13  BSC  T3121  BSC T14  BSC  T3166n  MFS T18_Overload  BSC  T3169  MFS T20  BSC  T3190n  MFS T200_D3  BTS  T3192 (MFS)  MFS T200_OMU  BTS  T3212 (MFS)  MFS T200_ST  BTS  T5_RA_CAP_UPDATE  MFS T200_TRE  BTS  T9101  BSC T203_GSL (BSC)  BSC  T9103  BSC 

Page 75: 45847764 GSM Timers Document

Mobilink Confidential Property 

75

Timer   Entity  Timer  Entity T3103  BSC  T9108  BSC T3105_F_FR  BSC  T9113  BSC T3106_D  BSC  T9104  BSC T3106_F_STOP  BSC  T9110  BSC T3111  BSC  T9105  BSC T3122  BSC  T9112  BSC 

Page 76: 45847764 GSM Timers Document

Mobilink Confidential Property 

76

7.3    HUAWEI TIMERS  

Timers T200 SDCCH SAPI3(5ms)  PBGT Valid Time(s) T200 SACCH SDCCH(10ms)  PBGT Watch Time(s) T200 SACCH TCH SAPI3(10ms)  Layer HO Valid Time(s) T200 SACCH TCH SAPI0(10ms)  Layer HO Watch Time(s) T200 FACCH/H(5ms)  Edge HO AdjCell Valid Time(s) T200 FACCH/F(5ms)  Edge HO AdjCell Watch Time(s) T200 SDCCH(5ms)  Edge HO Valid Time(s) AHR Radio Link Timeout(SACCH period (480ms))  Edge HO Watch Time(s) AFR Radio Link Timeout(SACCH period (480ms))  Update Period of CH Record(min) AHR SACCH Multi‐Frames(SACCH period (480ms))  TCH Minimum Recovery Time(s) AFR SACCH Multi‐Frames(SACCH period (480ms))  Release Delay of Downlink TBF(ms) SACCH Multi‐Frames(SACCH period (480ms))  Inactive Period of Extended Uplink TBF(ms) TDD 3G Better Cell HO Valid Time(s)  Release Delay of Non‐extended Uplink TBF(ms) TDD 3G Better Cell HO Watch Time(s)  Cell Reselect Interval(s) Quick Handover Punish Time(s)  Cell Penalty Last Time(s) Quick Handover Last Time (0.5s)  Cell Reselection Forbidden Time Quick Handover Static Time(0.5s)  Non‐DRX Period Number of Satisfactory Measurements(s)  GPRS Penalty Time Total Number of Measurements(s)  Extension MR Period Inter UL And OL Subcells HO Penalty Time(s)  Max. Duration of DRX(s) OL Subcell Load Diversity HO Period(s)  T3192 Modified Step Length of UL Load HO Period(s)  T3168 UL Subcell Load Hierarchical HO Period(s)  Cell Reselection MR Period in Packet Transfer Mode 3G Better Cell HO Valid Time(s)  Cell Reselection MR Period in Packet Idle Mode 3G Better Cell HO Watch Time(s)  Timer for UL Data Forward(ms) Penalty Time after OtoU HO Fail(s)  WaitforRelIndAMRHR Penalty Time after UtoO HO Fail(s)  WaitforRelIndAMRFR Penalty Time of UtoO HO(s)  T3103C(ms) Underlay HO Step Period(s)  T3122(s) UO HO Valid Time(s)  TREESTABLISH(ms) UO HO Watch Time(s)  T3111(ms) Penalty on MS Fast Moving HO  T3109(ms) CfgPenaltyTimer  T8(ms) UmPenaltyTimer  T3121(ms) RscPenaltyTimer  T3107(ms) Penalty Time after AMR TCHF‐H HO Fail(s)  T7(ms) Penalty Time after TA HO(s)  T3103A(ms) Penalty Time after BQ HO(s)  ImmAss A Interf Creation Timer(ms) Min Interval for Consecutive HOs  T3101(ms) Min Interval for SDCCH HOs  Aiding Delay Protect Time(min) Min Interval for TCH HOs  CCCH Load Indication Period(s) TIGHT BCCH HO Valid Time(s)  Radio Resource Report Period(s) TIGHT BCCH HO Watch Time(s)  Frame Start Time Intracell F‐H HO Last Time(s)  Interf.Calculation Period(SACCH period(480ms)) Intracell F‐H HO Stat Time(s)  Speed Penalty Time