  • Title

    Piping and Equipment Insulation

    Page no.

    1

    Total

    8Piping and Equipment InsulationDocument no.: 4294

    Process correspondence:Anskaffelse, Drift, HMS - risikostyring, Prosjekt, Vedlikehold

    Relevance to jobtitles:Isolatr, Overflatebehandler

    NORSOK Standard Reference:

    R-004, Piping and Equipment Insulation (Rev.3, August 2006)Document / Revision No. Owner Approved

    4294 / 03 Materials-and-Inspection-Leader 02.01.2007

  • Title

    Additional Requirements To Norsok Standard R-004

    Page no.

    2

    Total

    8Additional Requirements To Norsok Standard R-004

    Disclaimer:"The ConocoPhillips Norway specifications attached to this homepage are unofficial and uncontrolled versions and are set forth for information purposes only. Contractors who have contracts with ConocoPhillips Norway are advised that they must comply with the binding, controlled version of the specifications set forth in their contracts with ConocoPhillips Norway, and that they are responsible for ensuring proper compliance by their subcontractors with such controlled version of the specifications."

    For information please contact the following:

    A. Greig - [email protected]

    H. Monsen - [email protected] / Revision No. Owner Approved

    4294 / 03 Materials-and-Inspection-Leader 02.01.2007

  • Title

    Introduction

    Page no.

    3

    Total

    81 Introduction

    1.1 Purpose and Scope

    This document covers requirements and clarifications concerning NORSOK Standard R-004 Piping and Equipment Insulation , and shall always be read together with Norsok R-004. Requirements in Norsok R-004 are applicable unless otherwise stated in this document.

    This document is applicable to all ConocoPhillips Norways insulation work including:

    Construction of new platforms or modules

    Modification of existing platforms or modules

    Insulation of equipment and bulk items, either purchased directly by ConocoPhillips or supplied through other organisations

    It shall be observed that it is ConocoPhillips policy that the use of insulation shall be avoided if possible, in order to reduce the risk of corrosion under insulation.

    1.2 Responsibility and Ownership

    Materials and Inspection Leader is the owner of this document, and is responsible for updating or withdrawal of the document as dictated by organizational or operational changes.

    1.3 References

    NORSOK Standards:R-004 Piping and Equipment Insulation

    REVISED!ConocoPhillips References:

    4920 Control of Non-Conformity

    4293 Surface Preparation and Protective Coating

    3781 Maintenance of Surface Protection

    1.4 Non-conformances

    Deviations from requirements contained in this document and/or R-004 shall be adressed to the position responsible for this document, in accordance with document 4920 Control of Non-Conformity .Document / Revision No. Owner Approved

    4294 / 03 Materials-and-Inspection-Leader 02.01.2007

  • Title

    Technical Requirements

    Page no.

    4

    Total

    82 Technical Requirements

    2.1 Design of insulation systems (additional to R-004)

    The design and installation of insulation systems shall be such that the risk of ingress of water into the insulation shall be reduced to a minimum, and at the same time allow for proper drainage. The insulation contractor shall establish a document containing all insulation details, including removable jackets for valves and flanges, and present this for approval by ConocoPhillips prior to the start of insulation work. Methods for termination of non-metallic jacketing (tape) onto hot-service piping shall be taken into account. Carbon steel jacketing shall not be used at any time.

    2.2 Painting prior to the installation of insulation (additional to R-004)

    For all materials except titanium, it is a requirement that surfaces to be insulated shall be coated/painted. It is the insulation contractors responsibility to ensure that no insulation is carried out until coating/painting of all surfaces is 100% complete.

    2.3 Build-up of insulation systems on piping (additional to R-004)

    The build-up of insulation systems on piping shall be in accordance with Annex A1 - Insulation Build-Up on Piping (Internal Areas) on page 6 and Annex A2 - Insulation Build-Up on Piping (Weather-Exposed) on page 7 in this document.

    Non-metallic weatherproofing membrane (tape) shall be used as jacketing in internal areas of modules (including naturally ventilated modules) on insulation classes 1,2,4,6,7,8 and 9. The colour of the non-metallic jacketing shall be light grey. A thin aluminium foil shall be installed directly underneath the non-metallic weatherproofing membrane in order to simplify any future removal and replacement

    Aluminium jacketing shall be used in weather exposed / external areas on insulation classes 1,2,4,6,7,8 and 9

    The build-up of class 5 insulation is dependant on the relevant fire protection requirements, and is subject to ConocoPhillips acceptance. Stainless steel jacketing shall always be used on class 5 insulation. Class 5 insulation shall be made easily identifiable by installing markers (in accordance with Annex B - Marking of Class 5 Insulation on page 8) on the outside of the jacketing each 5 10 meters

    Products containing isocyanates shall not be used at any time Document / Revision No. Owner Approved

    4294 / 03 Materials-and-Inspection-Leader 02.01.2007

  • Title

    Technical Requirements

    Page no.

    5

    Total

    82.4 Flanges and valves (additional to R-004)

    Flanges and valves shall when possible be left un-insulated. The following shall be applicable when insulation of valves and flanges is required:

    Removable, deluge proof, tailor-made insulation jackets shall be used in internal areas on smaller valves (20 and smaller)

    Standard insulation boxes shall be used in weather exposed areas, and on large valves (larger than 20)

    Jackets and boxes shall be designed in order to avoid or minimise the entrance of water and to allow the drainage of water

    Removable jackets shall have identification marking on both the external and internal surface of the jacket

    Design of removable jackets shall be subject to ConocoPhillips approval

    2.5 Offshore maintenance of insulation (additional to R-004)

    Requirements applicable to offshore maintenance of insulation systems are described in ConocoPhillips document 3781 Maintenance of Surface Protection. Document / Revision No. Owner Approved

    4294 / 03 Materials-and-Inspection-Leader 02.01.2007

  • Title

    Technical Requirements

    Page no.

    6

    Total

    8Annex A1 - Insulation Build-Up on Piping (Internal Areas)

    CLASS AND SERVICE JACKETING COMMENTS/ BUILD-UP

    Class 1,Heatconservation

    Non-metallic jack-eting(tape)

    Cellular glass +foil +non-metallic jacketing

    Class 2,Cold mediumconservation

    Non-metallic jack-eting(tape)

    Cellular glass +foil +non-metallic jacketing(vapour barrier as necessary)

    Class 3,Personnelprotection

    Perforated guards shall be of stainless steel

    Class 4,Frost-proofing

    Non-metallic jack-eting(tape)

    Cellular glass +foil +non-metallic jacketing(vapour barrier as necessary)

    Class 5,Fire-proofing

    316 stainless steel

    Materials are dependant on fire protection requirements, to be accepted by ConocoPhillips for each case

    Class 6,Acoustic, -10dB

    Non-metallic jack-eting(tape)

    Cellular glass +acoustic insulant as necessary +foil +non-metallic jacketing

    Class 7,Acoustic, -20dB

    Non-metallic jack-eting(tape)

    Cellular glass +acoustic insulant as necessary +foil +non-metallic jacketing

    Class 8,Acoustic, -30dB

    Non-metallic jack-eting(tape)

    Cellular glass +acoustic insulant as necessary +foil +non-metallic jacketing

    Class 9,Ext. condensation and icing protection

    Non-metallic jack-eting(tape)

    Cellular glass +foil +non-metallic jacketing(vapour barrier as necessary)Document / Revision No. Owner Approved

    4294 / 03 Materials-and-Inspection-Leader 02.01.2007

  • Title

    Technical Requirements

    Page no.

    7

    Total

    8Annex A2 - Insulation Build-Up on Piping (Weather-Exposed)

    REVISED!

    CLASS AND SERVICE JACKETING COMMENTS/ BUILD-UP

    Class 1,Heatconservation

    Non-metallic jacketing (tape) + aluminium jacketing

    Cellular glass + foil + tape + aluminium jacketing

    Class 2,Cold mediumconservation

    Non-metallic jacketing (tape) + aluminium jacketing

    Cellular glass + foil + tape + aluminium jacketing (vapour barrier as necessary)

    Class 3,Personnelprotection

    Perforated guards shall be of stainless steel

    Class 4,Frost-proofing

    Non-metallic jacketing (tape) + aluminium jacketing

    Cellular glass + foil + tape + aluminium jacketing(vapour barrier as necessary)

    Class 5,Fire-proofing

    316 stainless steel Materials are dependant on fire protection requirements, to be accepted by ConocoPhillips for each case

    Class 6,Acoustic, -10dB

    Non-metallic jacketing (tape) + aluminium jacketing

    Cellular glass + acoustic insulant + foil + tape + aluminium jacketing

    Class 7,Acoustic, -20dB

    Non-metallic jacketing (tape) + aluminium jacketing

    Cellular glass + acoustic insulant + foil + tape + aluminium jacketing

    Class 8,Acoustic, -30dB

    Non-metallic jacketing (tape) + aluminium jacketing

    Cellular glass + acoustic insulant + foil + tape + aluminium jacketing

    Class 9,Ext. condensation and icing protection

    Non-metallic jacketing (tape) + aluminium jacketing

    Cellular glass + foil + tape + aluminium jacketing(vapour barrier as necessary)Document / Revision No. Owner Approved

    4294 / 03 Materials-and-Inspection-Leader 02.01.2007

  • Title

    Technical Requirements

    Page no.

    8

    Total

    8Annex B - Marking of Class 5 InsulationDocument / Revision No. Owner Approved

    4294 / 03 Materials-and-Inspection-Leader 02.01.2007

    DocTitle - Piping and Equipment InsulationHeading1 - Additional Requirements To Norsok Standard R-004Heading5 - Disclaimer:

    Heading1 - 1 IntroductionHeading2 - 1.1 Purpose and ScopeHeading2 - 1.2 Responsibility and OwnershipHeading2 - 1.3 ReferencesHeading5 - NORSOK Standards:Heading5 - ConocoPhillips References:

    Heading2 - 1.4 Non-conformances

    Heading1 - 2 Technical RequirementsHeading2 - 2.1 Design of insulation systems (additional to R-004)Heading2 - 2.2 Painting prior to the installation of insulation (additional to R-004)Heading2 - 2.3 Build-up of insulation systems on piping (additional to R-004)Heading2 - 2.4 Flanges and valves (additional to R-004)Heading2 - 2.5 Offshore maintenance of insulation (additional to R-004)

    Heading1NoNumber - Annex A1 - Insulation Build-Up on Piping (Internal Areas)Heading1NoNumber - Annex A2 - Insulation Build-Up on Piping (Weather-Exposed)Heading1NoNumber - Annex B - Marking of Class 5 Insulation