4294pipingequip insulation_rev3-020107 conoco philips
DESCRIPTION
InsulationTRANSCRIPT
-
Title
Piping and Equipment Insulation
Page no.
1
Total
8Piping and Equipment InsulationDocument no.: 4294
Process correspondence:Anskaffelse, Drift, HMS - risikostyring, Prosjekt, Vedlikehold
Relevance to jobtitles:Isolatr, Overflatebehandler
NORSOK Standard Reference:
R-004, Piping and Equipment Insulation (Rev.3, August 2006)Document / Revision No. Owner Approved
4294 / 03 Materials-and-Inspection-Leader 02.01.2007
-
Title
Additional Requirements To Norsok Standard R-004
Page no.
2
Total
8Additional Requirements To Norsok Standard R-004
Disclaimer:"The ConocoPhillips Norway specifications attached to this homepage are unofficial and uncontrolled versions and are set forth for information purposes only. Contractors who have contracts with ConocoPhillips Norway are advised that they must comply with the binding, controlled version of the specifications set forth in their contracts with ConocoPhillips Norway, and that they are responsible for ensuring proper compliance by their subcontractors with such controlled version of the specifications."
For information please contact the following:
A. Greig - [email protected]
H. Monsen - [email protected] / Revision No. Owner Approved
4294 / 03 Materials-and-Inspection-Leader 02.01.2007
-
Title
Introduction
Page no.
3
Total
81 Introduction
1.1 Purpose and Scope
This document covers requirements and clarifications concerning NORSOK Standard R-004 Piping and Equipment Insulation , and shall always be read together with Norsok R-004. Requirements in Norsok R-004 are applicable unless otherwise stated in this document.
This document is applicable to all ConocoPhillips Norways insulation work including:
Construction of new platforms or modules
Modification of existing platforms or modules
Insulation of equipment and bulk items, either purchased directly by ConocoPhillips or supplied through other organisations
It shall be observed that it is ConocoPhillips policy that the use of insulation shall be avoided if possible, in order to reduce the risk of corrosion under insulation.
1.2 Responsibility and Ownership
Materials and Inspection Leader is the owner of this document, and is responsible for updating or withdrawal of the document as dictated by organizational or operational changes.
1.3 References
NORSOK Standards:R-004 Piping and Equipment Insulation
REVISED!ConocoPhillips References:
4920 Control of Non-Conformity
4293 Surface Preparation and Protective Coating
3781 Maintenance of Surface Protection
1.4 Non-conformances
Deviations from requirements contained in this document and/or R-004 shall be adressed to the position responsible for this document, in accordance with document 4920 Control of Non-Conformity .Document / Revision No. Owner Approved
4294 / 03 Materials-and-Inspection-Leader 02.01.2007
-
Title
Technical Requirements
Page no.
4
Total
82 Technical Requirements
2.1 Design of insulation systems (additional to R-004)
The design and installation of insulation systems shall be such that the risk of ingress of water into the insulation shall be reduced to a minimum, and at the same time allow for proper drainage. The insulation contractor shall establish a document containing all insulation details, including removable jackets for valves and flanges, and present this for approval by ConocoPhillips prior to the start of insulation work. Methods for termination of non-metallic jacketing (tape) onto hot-service piping shall be taken into account. Carbon steel jacketing shall not be used at any time.
2.2 Painting prior to the installation of insulation (additional to R-004)
For all materials except titanium, it is a requirement that surfaces to be insulated shall be coated/painted. It is the insulation contractors responsibility to ensure that no insulation is carried out until coating/painting of all surfaces is 100% complete.
2.3 Build-up of insulation systems on piping (additional to R-004)
The build-up of insulation systems on piping shall be in accordance with Annex A1 - Insulation Build-Up on Piping (Internal Areas) on page 6 and Annex A2 - Insulation Build-Up on Piping (Weather-Exposed) on page 7 in this document.
Non-metallic weatherproofing membrane (tape) shall be used as jacketing in internal areas of modules (including naturally ventilated modules) on insulation classes 1,2,4,6,7,8 and 9. The colour of the non-metallic jacketing shall be light grey. A thin aluminium foil shall be installed directly underneath the non-metallic weatherproofing membrane in order to simplify any future removal and replacement
Aluminium jacketing shall be used in weather exposed / external areas on insulation classes 1,2,4,6,7,8 and 9
The build-up of class 5 insulation is dependant on the relevant fire protection requirements, and is subject to ConocoPhillips acceptance. Stainless steel jacketing shall always be used on class 5 insulation. Class 5 insulation shall be made easily identifiable by installing markers (in accordance with Annex B - Marking of Class 5 Insulation on page 8) on the outside of the jacketing each 5 10 meters
Products containing isocyanates shall not be used at any time Document / Revision No. Owner Approved
4294 / 03 Materials-and-Inspection-Leader 02.01.2007
-
Title
Technical Requirements
Page no.
5
Total
82.4 Flanges and valves (additional to R-004)
Flanges and valves shall when possible be left un-insulated. The following shall be applicable when insulation of valves and flanges is required:
Removable, deluge proof, tailor-made insulation jackets shall be used in internal areas on smaller valves (20 and smaller)
Standard insulation boxes shall be used in weather exposed areas, and on large valves (larger than 20)
Jackets and boxes shall be designed in order to avoid or minimise the entrance of water and to allow the drainage of water
Removable jackets shall have identification marking on both the external and internal surface of the jacket
Design of removable jackets shall be subject to ConocoPhillips approval
2.5 Offshore maintenance of insulation (additional to R-004)
Requirements applicable to offshore maintenance of insulation systems are described in ConocoPhillips document 3781 Maintenance of Surface Protection. Document / Revision No. Owner Approved
4294 / 03 Materials-and-Inspection-Leader 02.01.2007
-
Title
Technical Requirements
Page no.
6
Total
8Annex A1 - Insulation Build-Up on Piping (Internal Areas)
CLASS AND SERVICE JACKETING COMMENTS/ BUILD-UP
Class 1,Heatconservation
Non-metallic jack-eting(tape)
Cellular glass +foil +non-metallic jacketing
Class 2,Cold mediumconservation
Non-metallic jack-eting(tape)
Cellular glass +foil +non-metallic jacketing(vapour barrier as necessary)
Class 3,Personnelprotection
Perforated guards shall be of stainless steel
Class 4,Frost-proofing
Non-metallic jack-eting(tape)
Cellular glass +foil +non-metallic jacketing(vapour barrier as necessary)
Class 5,Fire-proofing
316 stainless steel
Materials are dependant on fire protection requirements, to be accepted by ConocoPhillips for each case
Class 6,Acoustic, -10dB
Non-metallic jack-eting(tape)
Cellular glass +acoustic insulant as necessary +foil +non-metallic jacketing
Class 7,Acoustic, -20dB
Non-metallic jack-eting(tape)
Cellular glass +acoustic insulant as necessary +foil +non-metallic jacketing
Class 8,Acoustic, -30dB
Non-metallic jack-eting(tape)
Cellular glass +acoustic insulant as necessary +foil +non-metallic jacketing
Class 9,Ext. condensation and icing protection
Non-metallic jack-eting(tape)
Cellular glass +foil +non-metallic jacketing(vapour barrier as necessary)Document / Revision No. Owner Approved
4294 / 03 Materials-and-Inspection-Leader 02.01.2007
-
Title
Technical Requirements
Page no.
7
Total
8Annex A2 - Insulation Build-Up on Piping (Weather-Exposed)
REVISED!
CLASS AND SERVICE JACKETING COMMENTS/ BUILD-UP
Class 1,Heatconservation
Non-metallic jacketing (tape) + aluminium jacketing
Cellular glass + foil + tape + aluminium jacketing
Class 2,Cold mediumconservation
Non-metallic jacketing (tape) + aluminium jacketing
Cellular glass + foil + tape + aluminium jacketing (vapour barrier as necessary)
Class 3,Personnelprotection
Perforated guards shall be of stainless steel
Class 4,Frost-proofing
Non-metallic jacketing (tape) + aluminium jacketing
Cellular glass + foil + tape + aluminium jacketing(vapour barrier as necessary)
Class 5,Fire-proofing
316 stainless steel Materials are dependant on fire protection requirements, to be accepted by ConocoPhillips for each case
Class 6,Acoustic, -10dB
Non-metallic jacketing (tape) + aluminium jacketing
Cellular glass + acoustic insulant + foil + tape + aluminium jacketing
Class 7,Acoustic, -20dB
Non-metallic jacketing (tape) + aluminium jacketing
Cellular glass + acoustic insulant + foil + tape + aluminium jacketing
Class 8,Acoustic, -30dB
Non-metallic jacketing (tape) + aluminium jacketing
Cellular glass + acoustic insulant + foil + tape + aluminium jacketing
Class 9,Ext. condensation and icing protection
Non-metallic jacketing (tape) + aluminium jacketing
Cellular glass + foil + tape + aluminium jacketing(vapour barrier as necessary)Document / Revision No. Owner Approved
4294 / 03 Materials-and-Inspection-Leader 02.01.2007
-
Title
Technical Requirements
Page no.
8
Total
8Annex B - Marking of Class 5 InsulationDocument / Revision No. Owner Approved
4294 / 03 Materials-and-Inspection-Leader 02.01.2007
DocTitle - Piping and Equipment InsulationHeading1 - Additional Requirements To Norsok Standard R-004Heading5 - Disclaimer:
Heading1 - 1 IntroductionHeading2 - 1.1 Purpose and ScopeHeading2 - 1.2 Responsibility and OwnershipHeading2 - 1.3 ReferencesHeading5 - NORSOK Standards:Heading5 - ConocoPhillips References:
Heading2 - 1.4 Non-conformances
Heading1 - 2 Technical RequirementsHeading2 - 2.1 Design of insulation systems (additional to R-004)Heading2 - 2.2 Painting prior to the installation of insulation (additional to R-004)Heading2 - 2.3 Build-up of insulation systems on piping (additional to R-004)Heading2 - 2.4 Flanges and valves (additional to R-004)Heading2 - 2.5 Offshore maintenance of insulation (additional to R-004)
Heading1NoNumber - Annex A1 - Insulation Build-Up on Piping (Internal Areas)Heading1NoNumber - Annex A2 - Insulation Build-Up on Piping (Weather-Exposed)Heading1NoNumber - Annex B - Marking of Class 5 Insulation