4/26/2017 microscada pro sys 600 9.2 mikael molander fisub/Österbacka
DESCRIPTION
Contents Pro Workplace Process Displays Measurement Reports Lists OPC Communication Engineering SQL Exporter Hardware Lock DocumentationTRANSCRIPT
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
1 -
MicroSCADA ProSYS 600 9.2
Mikael Molander
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
2 -
Contents
Pro Workplace Process Displays Measurement Reports Lists OPC Communication Engineering SQL Exporter Hardware Lock Documentation
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
3 -
Pro Workplace
Flexibility and Customizability
Toolbars & MenusFlexible Actions:- Open displays- Run Visual SCIL- Run SCIL- Etc.
Toolbars & Menus- Set Authorization level
Toolbars & Menus- Localize
Toolbars & MenusSet visibility- System- Application- User
Open a “Light” window- No menus- No toolbars
Change size and color of Note Marker
Lock Toolbars
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
4 -
Contents
Pro Workplace Process Displays Measurement Reports Lists OPC Communication Engineering SQL Exporter Hardware Lock Documentation
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
5 -
Process Displays
One common Network Topology Coloring model (option) Harmonized coloring between different displays
New coloring modes for line indicators Adjacent line segment Color given in Display Builder DMS 600 coloring
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
6 -
Process Displays
Zooming and Navigation:- Mouse wheel- 100% shortcut- Save/restore zoom areas
3 State Switch
4 New measurement symbols
Alarm indicator with up to 8 signals
Color Schemes
New actions for symbols:- Run SCIL- Open Visual SCIL dlgs- Open ActiveX- Authorization, etc.
PCM 600 Integration - Drag and drop engineering - User authentication and access rights
Authority allocation on any level of the substation structure - station, voltage level, bay, …
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
7 -
Contents
Pro Workplace Process Displays Measurement Reports Lists OPC Communication Engineering SQL Exporter Hardware Lock Documentation
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
8 -
Measurement Reports New Display Type: Measurement Report
Compatible with LIB 510 - Migrate data and display conf.
Copy to clipboard and export to file (csv).
Graphical view with area plot
Edit values
Comment
Zoom and Pan
Hair line
Flexible axis and curve settings
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
9 -
Contents
Pro Workplace Process Displays Measurement Reports Lists OPC Communication Engineering SQL Exporter Hardware Lock Documentation
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
10 -
Lists
Make blockings
Freely configurable colors
Locate Object - in Process Display - In DMS
New filtering function - Easy and fast - AND & OR groups
Reset Filer button
Alarm List:Sorting by selectable attribute
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
11 -
Contents
Pro Workplace Process Displays Measurement Reports Lists OPC Communication Engineering SQL Exporter Hardware Lock Documentation
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
12 -
OPC - Contents
OPC Servers OPC Clients Application OPC Server
- OPC DA Server for HSB Systems
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
13 -
OPC Servers
To allow external systems to read and write SYS 600 data, acknowledge alarms, etc.
SYS 600
External System
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
14 -
OPC Servers
Existing already OPC Data Access Server
All data in SYS 600 can be accessed No configuration needed with default namespace Optionally freely configurable namespace
New in 9.2 OPC Alarms and Events Server
For Clients that needs data through the A&E interface Configured by the process objects and event handling objects Freely configurable Process Areas, Event Sources, Condition
Names, Event Categories, Severity, etc.
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
15 -
OPC A&E Server
Allows alarms and events of SYS 600 to be transferred to a foreign system according to the OPC A&E specification
Main driver: Integration with Process Automation and especially System
800xA
Process database
OPC A&E ClientForeign System
OPC A&E ServerOPC A&E ClientForeign System
DCOM
SYS 600
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
16 -
OPC A&E Server
Functionality Transfer Alarms and events to a foreign system (A&E
Client) The foreign system can acknowledge alarms
SYS 600
800xA Alarm and Event List
800xA Breaker Faceplate (OPC DA)
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
17 -
OPC Clients
To allow devices / IEDs / systems to be connected to SYS 600, E.g. PLCs IED’s over un-supported protocols SNMP Network Managers Etc.
SYS 600
?
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
18 -
SYS 600
OPC Clients
Existing already External OPC Data Access Client (CPI interface) OPC Alarms and Events Client (introduced in 9.1.5)
New in 9.2 OPC Data Access Client
Corresponding functionality as in the External OPC DA Client Easier to configure and handle
DA Client
DA Server A&E Server
A&E Client
DA ClientExternal
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
19 -
OPC Clients
DA and A&E Clients (Integrated) Fully integrated in the base system
Easier handling: automatic stating, stopping, … Cannot be distributed to separate computer
Configured by NOD:B, STA:B and Process Objects OPC Item Name is the “address” of the Process Object Simple engineering
Runs on the SYS 600 PC The OPC Server can be in a separate PC (DCOM)
NOTE – The External OPC DA Client is used for the IEC 61850 OPC Server!
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
20 -
OPC Clients
The preferred way!
AE Client
AE Server DA Server
DA Client
Process database
DA Server
DA Client
Process database
If You must…
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
21 -
Application OPC Server
OPC DA Server for HSB Systems Provides one OPC DA server interface for a Hot-Stand-By
System The OPC DA Client (foreign system) does not have to
consider Hot/Standby, Takeovers, etc.
Process database
OPC DA Server OPC DA Client
Foreign System
DCOM
SYS 600
Process database
OPC DA Server
SYS 600
Application OPC DA Server
E.g. HIS 600
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
22 -
OPC Summary
DA Client
Process database
A&E Client
DA ServerA&E Server
DA ClientA&E Client
Application OPC Server (DA)
DA Server
HSB system
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
23 -
Contents
Pro Workplace Process Displays Measurement Reports Lists OPC Communication Engineering SQL Exporter Hardware Lock Documentation
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
24 -
Communication
SPA Routing in COM 500i Parameter Setting and Disturbance Upload
from SYS 600 NCC through COM 500i With LIB 510 IED tools To NCC: IEC 60870-5-101/104 To IEDs: SPA, LON, IEC 61850
IEC 61850 Server For system supervision and authority
allocation with non-MicroSCADA Pro based products
COM 581, RTU 560, …
SPA over TCP/IP IEC60870-5-104 redundancy
Both master and slave
SubstationSYS 600/COM 500i
NCCSYS 600
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
25 -
Communication Extensions to Modbus master
Extended REF 542plus Support Topic types, Events, Time synchronization, …
Enhanced flexibility in device integration Single bits, Transparent modbus messages, …
General interrogation enhancements
Extensions to DNP3.0 Conformance to specification updates (technical bulletins)
Double bit input (Group 3) and double bit input event (Group 4) objects (slave)
Uninterrupted select-before-operate (master)
Internal indication (IIN) status word from the IED updates a process object (master)
-> Easier application engineering
Collision-free polling in multidrop configuration (master)-> More robust communication
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
26 -
Contents
Pro Workplace Process Displays Measurement Reports Lists OPC Communication Engineering SQL Exporter Hardware Lock Documentation
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
27 -
SCL Importer
Functional Overview Imports SCL file (Connectivity Package) and creates the
process database structured as Standard Functions SCD (Substation Configuration Description) CID (Configured IED Description) -> Easy and consistent data entry
For ABB IEDs (Connectivity Packages) For SCL files of 3rd party IEDs
With some requirements on the SCL files
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
28 -
SCL Importer
Preview function To verify and show the contents of the SCL file
-> Better transparency and overview of the data import
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
29 -
SCL Importer
Can create database of LON & SPA type as well Select station type and unit number in the Preview Window
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
30 -
SCL Importer
Language support You can import signal texts of different languages from the
Connectivity Packages-> Consistent texts
-> Easy data entry
More complete handling of protection related information-> More complete reuse of SCL information
Improved exception handling-> More robust and transparent data handling
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
31 -
Contents
Pro Workplace Process Displays Measurement Reports Lists OPC Communication Engineering SQL Exporter Hardware Lock Documentation
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
32 -
SQL Exporter
Overview The SQL Exporter lets you configure process data to be
exported to a relational database over ODBC Data can be sent both cyclically and event based
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
33 -
Contents
Pro Workplace Process Displays Measurement Reports Lists OPC Communication Engineering SQL Exporter Hardware Lock Documentation
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
34 -
Hardware Lock
SYS 600 9.2 has a hardware lock mechanism Used to couple a license to one physical system The hardware lock is implemented by means of USB sticks The license is bound to a specific USB stick my means of the
HW_KEY field in the license
NOTE! The USB Stick is independent from functionality and product version.
No need to change USB Stick at:- Extensions- Upgrades- Hardware changes
License
SYSTEM_ID = 1017001HW_KEY = R-AL-12345 …
MS Pro12345
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
35 -
USB Stick Usage
MS Pro12345
License
SYSTEM_ID = 1017001HW_KEY = R-AL-12345…
Redundant (HSB) Systems One USB Stick in one of the PCs Which PC that has the key does not matter If the PC with the key is down for more than a week,
the key has to be moved to the other PC If this is not accepted, double keys can be requested
when ordering the license
One License
License
SYSTEM_ID = 1017001HW_KEY = R-AL-12345 …
MS Pro12345
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
36 -
USB Stick Usage
MS Pro12345
Demo License
SYSTEM_ID = 1017001HW_KEY =…
Demo Licenses No USB Sticks required
License
SYSTEM_ID = 1017001HW_KEY = R-AL-12345 …
MS Pro12345
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
37 -
USB Stick and License handling
Engineering Centers should keep USB Sticks on stock1. Order USB Sticks for e.g. 6 months of system deliveries -
Free of charge Send request to [email protected] In the first request specify:
Responsible person Delivery address
To order a License Fill in the Ordering Tool
MS Pro Ordering Tool for SYS 600 9.2 and DMS 600 4.2 (vX.Y).xls
Send the Ordering Tool to [email protected]
License
SYSTEM_ID = 1017001HW_KEY = R-AL-12345 …
MS Pro12345
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
38 -
USB Stick and License handling
Deliver a new system1. Order License
The license will be made for a free USB stick that you have on stock
2. When you receive the license, pick the right USB stick and install in your system
Extend an existing system1. Order License
Include the System ID of the existing license
2. Install the new license It is made for the USB stick already installed in the system
License
SYSTEM_ID = 1017001HW_KEY = R-AL-12345 …
MS Pro12345
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
39 -
USB Stick and License handling
Upgrade existing system (from pre 9.2 version)1. Order License
Include the System ID of the existing license The license will be made for a free USB stick that you have
on stock
2. When you receive the license, pick the right USB stick and install in your system
License
SYSTEM_ID = 1017001HW_KEY = R-AL-12345 …
MS Pro12345
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
40 -
Hardware Lock Checking
No USB stick available Corresponds to a missing license
When the USB stick has been installed and validated The system runs without limitations If the USB stick becomes unavailable (broken, removed,
etc.): The system runs without limitations for one week. After that the
functionality is disabled if the system is restarted.
-> Time to fix! The system reports the failure twice a day (-> alarm)
License
SYSTEM_ID = 1017001HW_KEY = R-AL-12345 …
MS Pro12345
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
41 -
Contents
Pro Workplace Process Displays Measurement Reports Lists OPC Communication Engineering SQL Exporter Hardware Lock Documentation
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
42 -
Documentation
All Manuals have been updated
New Manual IEC 61850 System Design
Major updates Operation Manual Application Design Process Display Design OPC Server Coming soon:
Installation and Administration System Configuration
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
43 -
Summary
Pro workplaceFlexibility and customizability
New Measurement Reports
Process DisplayMany new features and common Network Topology model
ListsFilteringSortingColoringBlockingsLocate objects
DA Client
Process database
A&E Client
DA Server
A&E Server
DA Client
A&E Client
Application OPC Server (DA)
DA Server
HSB system
OPC Interfaces in all directions
CommunicationSPA over TCP/IPIEC 104 redundancyModbus master, DNP3.0Etc.
SCL Importer extensions
SQL Exporter
Mic
roS
CA
DA
Pro
Par
tner
s C
lub
04/2
007©
AB
B -
44 -
Summary
Scalability
Gateway(COM 500i)
SYS 600
Single line diagram
Event List
Trends
IED Tools
Archiving and reporting
Data exchange
OPC, SQL, …
Blocking List
Alarm List
Data Mirroring Redundancy
Network Topology Coloring
Etc.