40g dwdm troubleshooting final 42273
DESCRIPTION
40g dwdmTRANSCRIPT
QUESTIONS: Submit questions at any time by using the ASK A QUESTION button in the webinar player. We will try to answer questions as they come.
SHARING: Share today’s webinar at any time with your network and colleagues with the SHARE THIS button
POLL: This session will contain a poll question that you’ll be able to answer. Vote and view the results by pressing the VOTE button.
SLIDES and RELATED DOCUMENTS: Today’s presentation and other related documents can be accessed via the ATTACHMENT button
POST-WEBINAR: This session will be made available for on-demand viewing immediately after its conclusion. You can access the recording using the same login information and link.
SURVEY: Once you close this player window, you will be automatically redirected to a short survey. Upon completion of the survey, you'll be entered to win a $500 VISA gift card. You may also rate this presentation using the RATE THIS button.
Housekeeping...
Troubleshooting a 40G DWDM Circuit, Step by Step
Case Study
Aaron Deragon Application Engineer, EXFO
January 14, 2014
4 © 2014 EXFO Inc. All rights reserved..
The Problem
› Customer contacted us stating:
› 40G link taking correctable FEC errors
› Initially, errors at one end
› Swapped Tx and Rx fibers, errors appeared at other end
› A problem on the fiber pair is suspected, but not visible
5 © 2014 EXFO Inc. All rights reserved..
Additional Information
› ~50 km link, including old fiber
› Currently, 17 active DWDM channels including one 40G
non-coherent channel
› Link is using non-coherent 40G cards:
› DQPSK muxponder ($40k USD on Ebay)
› 4 x 10G inputs – 1 x 40G output
› Up to 80 DWDM channels at 40G
› Boost amp
› Pre-amp
› 32-channel WSS (λ selective switch)
› 32-channel DMX (includes variable attenuators)
› CD compensators
8 © 2014 EXFO Inc. All rights reserved..
The Network
Amplifier
Amplifier
DCM
DCM
ROADM Functionality
ROADM Functionality
9 © 2014 EXFO Inc. All rights reserved..
The Network
Amplifier
Amplifier
DCM
DCM
~50km
ROADM Functionality
ROADM Functionality
10 © 2014 EXFO Inc. All rights reserved..
Hypothesis
› CD not suspected – short, compensated link
› Problem follows fiber, so PMD or ORL suspected
› Some fiber is very old (~20 years), potential PMD
› If ORL, then Tx would be disrupted and cause errors
› Only one fiber seems to be causing issues (errors at one end only)
11 © 2014 EXFO Inc. All rights reserved..
Goals
› Asked us to help by:
› Determining cause of errors on active link
› Pre-characterizing spare fiber pair to potentially roll to
12 © 2014 EXFO Inc. All rights reserved..
Equipment
› We used:
› FTB-730 with iOLM
› FTB-5240S-P with WDM Investigator
› FTB-5700
› FOT-930 and FTB-3930
› FIP-400D with cleaning supplies
13 © 2014 EXFO Inc. All rights reserved..
Equipment
› We used:
› FTB-730 with iOLM
› FTB-5240S-P with WDM Investigator
› FTB-5700
› FOT-930 and FTB-3930
› FIP-400D with cleaning supplies
14 © 2014 EXFO Inc. All rights reserved..
Our Process
› Larry
› iOLM spare fibers for loss, ORL and length
› UPC patchcord connector for FTB-5700
› Aaron
› OSA monitors all ports to piece story together
15 © 2014 EXFO Inc. All rights reserved..
Test Results – iOLM Spare Fiber 1
Good Loss Good ORL APC End Event
16 © 2014 EXFO Inc. All rights reserved..
Test Results – iOLM Spare Fiber 2
Good Loss Good ORL APC End Event
17 © 2014 EXFO Inc. All rights reserved..
Test Results – iOLM Spare Fiber 1
Good Loss Good ORL UPC End Event (now)
18 © 2014 EXFO Inc. All rights reserved..
Test Results – iOLM Spare Fiber 2
Good Loss Good ORL UPC End Event (now)
23 © 2014 EXFO Inc. All rights reserved..
Test Results – OSA at Location A on Fiber 1
40G
40G Channel λ = 1546.924nm OSNR = 35.55dB Power = -7.62dBm Noise floor = -43.16dBm
27 © 2014 EXFO Inc. All rights reserved..
Test Results – OSA at Location B on Fiber 2
40 G Channel λ = 1546.925nm OSNR = 34.67dB Power = -21.37dBm Noise Floor = -56.03dBm
40G
29 © 2014 EXFO Inc. All rights reserved..
Actions Taken
› One good spare fiber and one good in-service fiber
› Original testing performed on October 21
› Service rolled to good fibers on October 23
› Error-free operation since
30 © 2014 EXFO Inc. All rights reserved..
Deeper Dive
› On November 4, testing performed with FTB-5600 QP-OTDR
38 © 2014 EXFO Inc. All rights reserved..
Conclusion
› iOLM was perfect for single-ended ORL and loss testing
› FTB-5700 was perfect for single-ended PMD testing of dark
fiber
› FTB-5240S-P and WDMI was perfect for in-service, passive
PMD testing
› FTB-5600 QP-OTDR was perfect for identifying the specific
span to replace
› Customer requested iOLM upgrades, WDMI upgrades, trade
for FTB-5700 and possible FTB-5600 purchase ($300K)
39 © 2014 EXFO Inc. All rights reserved..