4040 wilson - mixed use building · 16 may 2016 sprc 1 pg 8 site design 22 176.39 17 255.22 the...
TRANSCRIPT
4040 Wilson - Mixed Use Building4040 Wilson - Mixed Use BuildingSPRC 1 – 16 May 2016SPRC 1 – 16 May 2016
Pg 216 May 2016 SPRC 14040 Wilson - Mixed Use Building Presentation Agenda
1. Project Overview2. Land Use & Zoning3. Site Design4. Building Architecture5. Transportation6. Open Space7. Community Benefits8. Construction Coordination
Presentation Agenda
16 May 2016 SPRC 14040 Wilson - Mixed Use Building Overall Site Plan Pg 3
Project OverviewCompletion of Liberty Center• Nine Buildings• 2,250,000 Square Feet• Started in 2001• Building completes the project
Purpose of Amendment:• Adjust Program to Trends in Market• Change Portion of Office Use to Residential• Expand Retail Offerings• Retain Option for Approved All-Office Scheme
SITE
Wilson Boulevard
Pedestrian Path
16 May 2016 SPRC 14040 Wilson - Mixed Use Building Existing Buildings Pg 4
Project OverviewPhotos of Existing Completed Buildings
The View DARPA Headquarters
One Liberty Center Two Liberty Center The Residences at Liberty CenterLiberty Tower
16 May 2016 SPRC 14040 Wilson - Mixed Use Building Overall Site Plan Pg 5
Project Overview
Wilson Boulevard
SITE
Existing View from Wilson Boulevard
Existing View from Randolph Street Aerial View – Existing Conditions
Photos of Existing Site Condition
16 May 2016 SPRC 14040 Wilson - Mixed Use Building Land Use and Zoning Pg 6
Land Use and Zoning
Previous Approval Proposed AmendmentSite Area 1.29 acres 1.29 acres
Percent Coverage 45% 45%
Office Area 419,830 gsf 191,300 gsf
Retail Area 7,670 gsf 33,400 gsf
Residential Area 0 213,800 gsf / 244 apartments
Service / Utility 4,350 gsf 4,590 gsf
Total GFA 427,500 gsf 427,500 gsf
Height to Main Roof 248’-11”; 20 stories 255’-3”; 22 stories
Penthouse Height 20’-0” 23’-0”
Parking Spaces Provided 544 sp 483 sp
Loading Berths 2 3
Sustainability Program LEED C&S v2009 GOLD LEED C&S VERSION 4 GOLD
Key Statistics
4040 Wilson - Mixed Use Building Slide Title16 May 2016 SPRC 1
Pg 7
Site DesignThe overall site design remains largely as previously approved, with only minor adjustments for the new program.
There are no changes to the following:• Relationship to Public Space & Adjacent Buildings• Streetscape Improvements• View Vistas through Site• Visibility of Buildings from Neighboring areas• Historic Status• Compliance with Adopted Planning
Approved Plan
Site Plan
WILSON BOULEVARDWILSON BOULEVARD
4040 Wilson - Mixed Use Building Context Elevations – Wilson Blvd16 May 2016 SPRC 1
Pg 8
Site Design
22
176.3917
255.22242.07THE ‘VIEW” (EX)
PROPOSED
NW MIXED USE
BQ RES
(Approved)
NW OFFICE
RES NORTH
Previously Approved All Office Design
Proposed Mixed-Use Design
BQ RES
(Approved)
22242.07
22278.22PH Roof
400’
OFF
SET
4040 Wilson - Mixed Use Building 16 May 2016 SPRC 1Pg 9
Site Design
Context Elevations – Randolph
Previously Approved All Office Design
Proposed Mixed-Use Design
154.9413
22255.22
PROPOSED
NW MIXED USE
OFFICE (EX)
112.589
152.5813
OFFICE (EX)
OFFICE (EX)
278.22PH Roof
4040 Wilson - Mixed Use Building Rendered Views16 May 2016 SPRC 1
Pg 10
Building ArchitectureApproximately half of the office area is proposedto be converted to residential use.• 244 apartments at top levels• Office use with a street retail remains at lower levels• Total building area is same as previously approved
Previously Approved All Office Design Proposed Mixed-Use Design KEY PLAN
Wilson
4040 Wilson - Mixed Use Building Building Sections16 May 2016 SPRC 1
Pg 11
Building Architecture
Section - Previously Approved All Office Design
Ground
P1P2P3P4P5
234
5
6
7
111098
121314
1516
20
19
18
PH
17
Offic
ePa
rkin
g
Ret
ail
248.94’
268.94’
Resid
entia
lOf
fice
Ret
ail
Park
ing
15
11121314
16171819202122PH
10
98
76
54
3
2
Ground
P1P2P3P4P5
255.22’
278.22’
Section - Proposed Mixed-Use DesignKEY PLAN
Wilson
4040 Wilson - Mixed Use Building Ground Floor16 May 2016 SPRC 1
Pg 12
Building Architecture
Previously Approved All Office Design Proposed Mixed Use Design
Office Lobby
Res Lobby
Retail
Service Dock
Ramp DownTo Parking
WILSON BLVDWILSON BLVD
Office Lobby
Retail
Retail
Service Dock
Ramp DownTo Parking
Ground floor includes modest changes to accommodate the new program.
4040 Wilson - Mixed Use Building Typical Office Floor16 May 2016 SPRC 1
Pg 13
Building Architecture191,500 GSF Office on Floors 2-10:• Previous Approval = 419,830 GSF Office• Typical Floorplate is virtually unchanged
Proposed Mixed-Use DesignPreviously Approved All-Office Design(22,300 gsf/flr)(21,755 gsf/flr)
4040 Wilson - Mixed Use Building Residential Floor16 May 2016 SPRC 1
Pg 14
Building Architecture244 Apartments on floors 11-22:• 20% are 2BR• 80% are 1BR• Average Unit Size of 876 GSF per Apt
In the event of a significant change in the market, demising walls can readily be adjusted and units combined without structural changes.
2BR APT
1BR APT
KEY
JR 1BR APT
TYPICAL RESIDENTIAL FLOOR
RESIDENTIAL AMENITY TERRACE AT FLOOR 11
2BR
4040 Wilson - Mixed Use Building Penthouse Level16 May 2016 SPRC 1
Pg 15
Building Architecture
PENTHOUSE LEVEL
OFFICE ROOF DECK
POOL
RES POOL DECK
4040 Wilson - Mixed Use Building Rendered View16 May 2016 SPRC 1
Pg 16
Building Architecture
KEY PLAN
Wilson
4040 Wilson - Mixed Use Building Aerial View16 May 2016 SPRC 1
Pg 17
Building Architecture
KEY PLAN
Wilson
4040 Wilson - Mixed Use Building Architectural Detail16 May 2016 SPRC 1
Pg 18
Building Architecture
4040 Wilson - Mixed Use Building Rendered View16 May 2016 SPRC 1
Pg 19
Building Architecture
View from Wilson BoulevardKEY PLAN
Wilson
Accent Brick
Vision Glass
Metal Trim
Metal Panel
Field Brick
4040 Wilson - Mixed Use Building Retail16 May 2016 SPRC 1
Pg 20
Building Architecture• Retail tenancy has expanded to include a
fitness spa in addition to street retail• Retail area expanded from 7,670 to 33,400 gsf:
• 15,000 gsf second floor• 7,400 gsf ground floor• 11,000 gsf below grade at P1
• Entrances remain focussed on street and Plaza• Fitness tenant will help activate the south end of
plaza
Previously Approved All Office Design
Proposed Mixed Use Design
Ground P1 Level 2ND Flr
Ground
Wilson
Wilson
4040 Wilson - Mixed Use Building Retail16 May 2016 SPRC 1
Pg 21
Building ArchitectureRetail Streetscape
KEY PLAN
Wilson
4040 Wilson - Mixed Use Building Ground Floor16 May 2016 SPRC 1
Pg 22
Building Architecture
Previously Approved All Office Design Proposed Mixed Use Design
Office Lobby
Res Lobby
Retail
Service Dock
Ramp DownTo Parking
WILSON BLVDWILSON BLVD
Office Lobby
Retail
Retail
Service Dock
Ramp DownTo Parking
Service/Trash includes an added service bay for the mixed use program; in lieu of ancillary retail at Randolph St.
Utility locations, venting locations/strategies, and exterior lighting remain unchanged from previous approval.
4040 Wilson - Mixed Use Building Accessibility16 May 2016 SPRC 1
Pg 23
Building Architecture
Key Accessibility Features:1. The building and surrounding site areas will be fully accessible and incorporate Universal Design features.
2. Power operated doors with sensor activation will be provided at all main building entrance locations.
3. There will be at-grade access to all first floor retail spaces.
4. Accessible Van parking will be located within the garage.
Accessibility
4040 Wilson - Mixed Use Building Transportation / Open Space16 May 2016 SPRC 1
Pg 24
Transportation / Open Space
No changes to open space: orientation, use, relationship to adjacent uses, or compliance with planning goals.
Landscape Plan Changes:• Minor Adjustments for Health Spa Entry• Steps Removed for Universal Access• Added Service Bay
Public access easement area remains as previously approved.
Wilson Boulevard
4040 Wilson - Mixed Use Building Transportation / Parking16 May 2016 SPRC 1
Pg 25
Transportation / Parking
Total Automobile Spaces Previous Approval 544 spaces; 471 allocated to Office at 1 sp / 892 gsf
Total Proposed this Amendment 483 spaces
Residential Spaces Req’d 196 spaces at 0.8 sp per Apt
Retail Spaces Req’d 58 spaces at 1sp / 580 gsf
Office Spaces Req’d 229 spaces at 1sp / 835 gsf
Class 1 Bicycle Spaces Previous Approval 57 spaces
Class 1 Bicycle Spaces this Amendment 132 spaces
Class 3 Bicycle Spaces Previous Approval 23 spaces
Class 3 Bicycle Spaces this Amendment 20 spaces
Due to proposed revised program of uses, trip generation is reduced resulting in improved level of service at surrounding street network.This amendment results in no changes to: street sections, vehicular/pedestrian routes, bike routes, delivery and drop off locations.
PARKING SUMMARY:
4040 Wilson - Mixed Use Building LEED Scorecard16 May 2016 SPRC 1
Pg 26
Community Benefits1. LEED GOLD C&S v4.0; Key Credits:
a. LEED Neighborhood Development Gold Certifiedb. Water Use Reduction and Meteringc. Construction Waste Managementd. Green Cleaninge. Electric Vehicle Charging Stations
2. Completion / Construction of the pedestrian path through the site.
3. Deliver $4.4 million for Mosiac Park
There is no change to the previously approved LEED-based bonus density.
4040 Wilson - Mixed Use Building Construction Coordination16 May 2016 SPRC 1
Pg 27
Construction Coordination1. Excavation and Garage are Complete2. Phasing3. In Context with Adjacent Projects4. Vehicle Staging, Parking, Routing5. Community Liason
SITE
Wilson Boulevard
4040 Wilson - Mixed Use Building The End16 May 2016 SPRC 1
Pg 28
T H A N K Y O U !T H A N K Y O U !