3_sd_e_11-12_n

3
Compressed air meter with display and totalizer function. Argon consumption measurement in a laser welding system. Calorimetric measuring principle The compressed air meter detects the standard volume flow directly (according to ISO 2533 and DIN 1343). This makes corrections, in case of temperature or pressure fluctuations, unnecessary. The high measurement dy- namics of the system enable the reliable detection of even minute quantities, e.g. leakage. High accuracy and repeat- ability are ensured by the integration of the measure- ment sensor’s key elements into a defined pipe length. Measuring compressed air consumption in air supply lines We offer additional compressed air sensors for larger measuring ranges on request, especially for supply and air supply lines. As an option compressed air sensors with exchangeable electronics, allowing subsequent calibration under oper- ating pressure, can also be used. product news Measurement to ISO 2533 and DIN 1343 possible. For compressed air in industrial use, argon, carbon dioxide, nitrogen. Large measuring range up to 700 Nm 3 /h. Larger measuring ranges on request. Fast response time and high response sensitivity. Volumetric flow quantity, flow velocity and temperature indication. To prevent your money from dissolving into thin air.    F    l   u    i    d   s   e   n   s   o   r   s   a   n    d    d    i   a   g   n   o   s    t    i   c   s   y   s    t   e   m   s bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition

Upload: bird99

Post on 11-Feb-2018

220 views

Category:

Documents


0 download

TRANSCRIPT

7/23/2019 3_SD_e_11-12_n

http://slidepdf.com/reader/full/3sde11-12n 1/2

Compressed air meter withdisplay and totalizer function.

Argon consumption measurement in alaser welding system.

Calorimetric measuring principle

The compressed air meter detects the standard volumeflow directly (according to ISO 2533 and DIN 1343). Thismakes corrections, in case of temperature or pressurefluctuations, unnecessary. The high measurement dy-namics of the system enable the reliable detection of evenminute quantities, e.g. leakage. High accuracy and repeat-ability are ensured by the integration of the measure-

ment sensor’s key elements into a defined pipe length.

Measuring compressed air consumption inair supply lines

We offer additional compressed air sensors for largermeasuring ranges on request, especially for supply andair supply lines.

As an option compressed air sensors with exchangeableelectronics, allowing subsequent calibration under oper-ating pressure, can also be used.

product news

Measurement to ISO 2533 and DIN 1343possible.

For compressed air in industrial use,

argon, carbon dioxide, nitrogen.

Large measuring range up to 700 Nm3/h.Larger measuring ranges on request.

Fast response time and high responsesensitivity.

Volumetric flow quantity, flow velocityand temperature indication.

To prevent your money fromdissolving into thin air.

 F l u i d s e n

 s o r s a n d d i a g n o s t i c

 s y s t e m s

bus,identification

and control systems

fluid sensorsand diagnostic

systems

positionsensors

and objectrecognition

7/23/2019 3_SD_e_11-12_n

http://slidepdf.com/reader/full/3sde11-12n 2/2

Measuring range

[Nm3/h]

Pulse value

[m3]

Measuring accuracy

[% of the final value]

Processconnection

Orderno.

Application: compressed air in industrial use, air quality DIN 8573-1,

class 141 (measurement error: value A) / class 344 (measurement error: value B)

0.06...15 0.001...1 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) G 1/4 SD5000

0.25...75 0.001...1 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) R 1/2 SD6000

0.25...75 0.001...1 000 000 ± (15 % MV + 1.5 % VMR) G 1/2 SD6050

0.75...225 0.003...3 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) R 1 SD8000

1.3...410 0.005...4 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) R 1 1/2 SD9000

2.3...700 0.010...4 000 000 A): ± (3 % MV + 0.3 % VMR) / B): ± (6 % MV + 0.6 % VMR) R 2 SD2000

Common technical data

Operating voltage [V] 19...30 DC

Analogue output [mA] 4...20

Housing materials

PBT-GF 20; PC (APEC),Makrolon;

stainless steel(304/1.4301); Viton

Materials(wetted parts)

high-grade stainless steel316L /1.4404; ceramics;glass passivated; PEEK

(polyetheretherketone);polyester; Viton;

aluminium; anodized

Medium temperature [°C] 0…60

Ambient temperature [°C] 0…60

Response time [s] < 0.1 (dAP = 0)

Pressure resistance [bar] 16

Protection IP65, III

Connection M12 connector

Short-circuit protection, pulsed •

Current rating [mA] 2 x 250

TypeSD

Connectors and splitter boxes

Type Description Orderno.

Socket, M12,2 m black, PUR cable

EVC004

Socket, M12,5 m black, PUR cable

EVC005

Socket, M12,10 m black, PUR cable

EVC006

Larger measuring ranges on request.

Reverse polarity / overload protection • / •

Application:argon (Ar), carbon dioxide (CO2), nitrogen (N2)

Ar: 0.08...24.54

CO2: 0.047...14.38N2: 0.05...14.94 0.001...1 000 000 (6% MV + 0.6% VMR) G 1/4 SD5100

Ar: 0.39...118.2CO2: 0.24...71.7N2: 0.24...73.0

0.001...1 000 000 (6% MV + 0.6% VMR) R 1/2 SD6100

   F   l  u   i   d  s  e  n

  s  o  r  s  a  n   d   d   i  a  g  n  o  s   t   i  c

  s  y  s   t  e  m  s

Flow sensors

For further technical data please go to: www.ifm.com   i   f  m  a  r   t   i  c   l  e  n  o .

   7   5   1   1   4   6   8  ·   P  r   i  n   t  e   d   i  n   G  e  r  m  a  n  y  o  n  n  o  n  -  c   h   l  o  r   i  n  e  p  a  p  e  r .  ·   W  e  r  e  s  e  r  v

  e   t   h  e  r   i  g   h   t   t  o  m  a   k  e   t  e  c   h  n   i  c  a   l  a   l   t  e  r  a   t   i  o  n  s  w   i   t   h  o  u   t  p  r   i  o  r  n  o   t   i  c  e .  ·   1   1 .   2

   0   1   1