3m™ intelligent return classic and sorter system fx architect...

40
3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor Package

Upload: others

Post on 26-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX

Architect/Contractor Package

Page 2: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M, 2015. All rights reserved.

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package, 78-8129-4938-2B.

3M is a trademark of 3M.

The original instructions in this document were written in U.S. English. All other languages are a translation of the original instructions.

Page 3: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Table of Contents

Introduction...........................................................................................................................................................................5

Using this architect/contractor package............................................................................................................................5

Caution: Use the correct architect/contractor package......................................................................................................5

Introducing the 3M™ Intelligent Return Classic and Sorter System FX..........................................................................6

System modules...............................................................................................................................................................7

3M™ Intelligent Return Classic..................................................................................................................................73M™ Intelligent Return Staff Model 2830..................................................................................................................7FX Sorter Model 2850.................................................................................................................................................8FX System Controller Model 2855..............................................................................................................................8FX Directional Conveyor Model 2860........................................................................................................................9FX Ramp Conveyor Model 2861..............................................................................................................................10FX Lift-Gate Conveyor Model 2862.........................................................................................................................10FX Two-foot Conveyor Model 2863.........................................................................................................................11FX Four-foot Conveyor Model 2864.........................................................................................................................11Bin Model 2899.........................................................................................................................................................12Premium metal bin....................................................................................................................................................12

Implementation responsibilities...........................................................................................................................................13

Facility requirements...........................................................................................................................................................14

Electrical requirements...................................................................................................................................................14

Intelligent Return units..............................................................................................................................................14FX System Controller Model 2855............................................................................................................................14Other Sorter System FX Models...............................................................................................................................15

Network requirements....................................................................................................................................................15

Environmental requirements...........................................................................................................................................15

Module weight...............................................................................................................................................................16

Module dimensions........................................................................................................................................................17

Intelligent Return Classic Models.............................................................................................................................17Intelligent Return Staff Model 2830..........................................................................................................................18FX Sorter Model 2850...............................................................................................................................................18FX System Controller Model 2855............................................................................................................................19FX Directional Conveyor Model 2860......................................................................................................................19FX Ramp Conveyor Model 2861..............................................................................................................................20FX Lift-Gate Conveyor Model 2862.........................................................................................................................21FX Two-Foot Conveyor Model 2863........................................................................................................................22FX Four-Foot Conveyor Model 2864........................................................................................................................22Model 2899 Bin.........................................................................................................................................................23Premium metal bin....................................................................................................................................................23

Wall construction: Models 2810 and 2812.....................................................................................................................24

Front elevation..........................................................................................................................................................24Side elevation............................................................................................................................................................25

Wall thickness and weight bearing capacity...................................................................................................................25

Minimum distances between RFID systems...................................................................................................................26

78-8129-4938-2B © 3M, 2015. All rights reserved. 3

Page 4: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Minimum distances to walls and obstructions................................................................................................................27

Minimum access requirements.......................................................................................................................................28

Install the surround.........................................................................................................................................................29

Insulate the surround of outdoor units............................................................................................................................30

Sample configurations.........................................................................................................................................................31

Three bin configuration..................................................................................................................................................31

Three bin configuration with Staff Intelligent Return.....................................................................................................32

Five bin configuration....................................................................................................................................................32

Five bin configuration with Staff Intelligent Return.......................................................................................................33

Seven bin configuration..................................................................................................................................................34

Seven bin configuration with Staff Intelligent Return....................................................................................................35

Seven bin configuration from two Intelligent Returns....................................................................................................36

Eleven bin configuration................................................................................................................................................37

Fifteen bin configuration................................................................................................................................................38

Warranty..............................................................................................................................................................................39

3M Service..........................................................................................................................................................................40

Information to gather......................................................................................................................................................40

3M Service phone numbers............................................................................................................................................40

3M Library Systems Web Site........................................................................................................................................40

78-8129-4938-2B © 3M, 2015. All rights reserved. 4

Page 5: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Introduction

Using this architect/contractor packageThis package provides architects and contractors with information necessary to prepare the site for the installation of the 3M Intelligent Return Classic and Sorter System FX. The information provided here must be followed to ensure optimal performance.

Before beginning new construction or changing an existing structure, contact 3M Library Systems TechnicalService at 1-800-328-0067 (website: http://www.3M.com/library) or your sales representative to:

• Confirm that you have the most recent version of this document.

• Verify that the proposed system can be installed in the planned space.

Caution: Use the correct architect/contractor packageThere are four architect/contractor packages that cover the Intelligent Return and SL and FX Sorter system models. They carry similar, but not identical information. Consequently, it is very important that you use the package intended for the equipment you plan to have installed at your library. Use the information in the following table to ensure that you are using the correct one.

Intelligent ReturnModels

Sorter SystemModel

Architect/Contractor Package to Use

2810 and 2812 Sorter System FX This architect/contractor package

2820 and 2822 Sorter System FX Intelligent Return Plus and Sorter System FX Architect/Contractor Package

2810 and 2812 Sorter System SL Intelligent Return Classic and Sorter System SL Architect/Contractor Package

2820 and 2822 Sorter System SL Intelligent Return Plus and Sorter System SL Architect/Contractor Package

78-8129-4938-2B © 3M, 2015. All rights reserved. 5

Page 6: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Introducing the 3M™ Intelligent Return Classic and Sorter System FXThe 3M Intelligent Return Classic and Sorter System FX is acomplete check-in and sorting system that is both affordable andreliable. It helps libraries increase automated check-in andcirculation and maintain a more accurate catalog, whileimproving productivity and customer service.

78-8129-4938-2B © 3M, 2015. All rights reserved. 6

2810-12_V2_FX_Overview

Page 7: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

System modules

Note: One 3M Intelligent Return or Staff Induction Unit is required per installation. A maximum of four is supported, which can include any combination of 3M Intelligent Return Units and Staff Induction Units.

3M™ Intelligent Return Classic

The 3M Intelligent Return Classic Model 2810 and Model 2812 providethe interface between patrons checking in items and the sortingoperation. These units are installed through the wall that separatespatron-accessible areas from a staff area, where sorting occurs. Theyprovide a simple, intuitive push button interface.

The following table lists differences between Models 2810 and 2812.

Model Installation Type Item-return door Return shelf type

2810 Interior wall None / open Extends from wall

2812 Exterior wall Automated Flush with wall

3M™ Intelligent Return Staff Model 2830

The Model 2830 enables staff to check in materials from the back office.

78-8129-4938-2B © 3M, 2015. All rights reserved. 7

Page 8: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

FX Sorter Model 2850

The Model 2850 Sorter either selectively passes items through to anothersystem module or diverts them into bins.

FX System Controller Model 2855

The system controller manages the sorting system.

Note: Typically the system controller will be mounted to a wall of the staff area where thesorter system is installed. An optional baseplate kit for the system controller is availableif the unit cannot be mounted to a wall. An optional webcam kit is available for the FXSystem Controller Model 2855.

78-8129-4938-2B © 3M, 2015. All rights reserved. 8

2855_iso

Page 9: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

FX Directional Conveyor Model 2860

The two-foot Model 2860 directional conveyor routes items straight through to the next unit or reroutes them at a right angle, enabling the directional changes required to consolidate returns from multiple 3M Intelligent Returns into a single sortation line.

Items coming in from Input 1 are diverted either left (2860L) or right (2860R). Input 2 is optional and will convey items straight through to the Output.

78-8129-4938-2B © 3M, 2015. All rights reserved. 9

2860-LInput 1

Input 2(Optional)

Output

2860-R Input 1

Input 2(Optional)

Output

2860 Configurations

2860_configs

Page 10: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

FX Ramp Conveyor Model 2861

The Model 2861 is a four-foot conveyor that can be tilted up or down. Typically, this unit will be used in configurations where the height of the 3M Intelligent Return has beenadjusted to accommodate differences in floor and pavement heights. Theheight of the intake side of unit can be set from 26 to 38 in. [660 to 965mm]. The outflow side will always be 36 in. [914 mm].

FX Lift-Gate Conveyor Model 2862

The Model 2862 is a four-foot conveyor that lifts up to provideaccess to equipment and areas of the room that in some systemconfigurations would be cut off by a conventional conveyor.

Note: The intake side is hinged and must be connected to a conveyor. Itcannot be directly connected to an induction unit.

78-8129-4938-2B © 3M, 2015. All rights reserved. 10

2862_iso

Intake

Page 11: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

FX Two-foot Conveyor Model 2863

The Model 2863 is a two-foot conveyor that passes items straight through to thenext unit in line.

FX Four-foot Conveyor Model 2864

The Model 2864 is a four-foot conveyor that passes items straightthrough to the next unit in line.

78-8129-4938-2B © 3M, 2015. All rights reserved. 11

2864_iso

Page 12: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Bin Model 2899

The Model 2899 bin is a four-wheel sort bin, equipped with a canvas linerand spring-loaded platform that automatically adjusts in height as it fillsand empties. It has a capacity of 175 to 250 items.

Premium metal bin

The premium steel bin features a rugged, welded metal design, a springloaded laminate platform that lifts items higher for improved ergonomics, anelevated handle for improved maneuverability, and an approximate capacityof 330 items.

78-8129-4938-2B © 3M, 2015. All rights reserved. 12

Premium_Bin_ISO

Page 13: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Implementation responsibilitiesThis section lists tasks required to install a system, identifies the party responsible for completing each task, andspecifies the order of task completion.

1. The library contacts 3M Technical Service (1-800-328-0067 ) (website: http://www.3M.com/library) or the 3M sales representative to ensure that it has the most recent version of this document.

2. The library and the 3M sales representative complete a Site Checklist and submit it to 3M.

3. The sales representative provides a System Layout Plan to the library.

4. The library (along with architect/contractor), sales representative, technician, and 3M Technical Service (phone) meet to discuss site preparation details.

5. The library prepares the site for the system, which includes addressing issues identified in the previous step and the following:

• Installing electrical service according to the requirements listed in Electrical requirements on page 14

• Ensuring compliance with the environmental requirements listed in Environmental requirements on page 15

• Installing a network connection according to requirements listed in Network requirements on page 15

• Providing sufficient space for the system according to the requirements in:

Module dimensions on page 17

Minimum access requirements on page 28

Minimum distances between RFID systemson page 26

Sample configurations on page 31

• Preparing a wall for system installation as described in Wall construction: Models 2810 and 2812 on page 24

• Installing the surround (U.S.) according to the requirements in Install the surround on page 29

• Insulating around the surround of outdoor units according to the information in on Insulate the surroundof outdoor units on page 30

6. The 3M sales representative confirms that wall openings for Intelligent Returns are cut and surrounds installed.

7. The 3M technician inspects the site to verify readiness for installation.

8. The 3M technician installs the system.

9. The library completes wall finishing, such as touch-up repair of minor surface damage, drywall taping and sanding, paint or wallpaper, baseboard, etc, after system installation is complete.

78-8129-4938-2B © 3M, 2015. All rights reserved. 13

Page 14: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Facility requirements

Electrical requirements

Intelligent Return units

All Intelligent Return units require noise-free and reliable power that conforms to the specifications below:

• A single AC power outlet located in the same room as the staff side (not the outside or side accessible to the public) of the Intelligent Return and within 6 feet [1.82 m] of the Intelligent Return.

• Service that conforms to the following specifications:

100–120 VAC, 1–phase, 60 Hz, 2.5 amps

200–240 VAC, 1–phase, 50Hz, 1.5 amps

15–20 amp line (North America) or a 10–16 amp line (all other locations)

FX System Controller Model 2855

The FX System Controller Model 2855 requires a single AC power outlet within 6 feet [1.82 m] of the unit and service that conforms to the following specifications:

• 100–120 VAC, 1–phase, 60 Hz, 7.5 amps

• 200–240 VAC, 1–phase, 50Hz, 3.8 amps

• A 15–20 amp line (North America) or a 10–16 amp line (all other locations)

Note:Systems installed prior to January 1, 2012 continue to have an additional requirement. The Model 2855 requiresa dedicated, isolated ground circuit. This must have aninsulated grounding wire (color coded green with yellowstripe) run directly from the building main serviceentrance panel or circuit panel to an isolated groundreceptacle (orange) in which the grounding terminal ispurposely insulated from the mounting box (NEMA 5–15isolated ground). This circuit is defined in Section 250–74No. 4 in the National Electric Code Handbook.

This requirement does not apply to systems installed afterJanuary 1, 2012.

78-8129-4938-2B © 3M, 2015. All rights reserved. 14

Page 15: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Other Sorter System FX Models

FX Sorter Model 2850, FX Directional Conveyor Model 2860, FX Ramp Conveyor Model 2861,FX Lift-Gate Conveyor Model 2862, FX Two-Foot Conveyor Model 2863, Four-Foot Conveyor Model 2864.

• A single AC power outlet within 6 feet [1.82 m] of the first unit.

• Service that conforms to the following specifications:

100–120 VAC, 1–phase, 60 Hz, 1.5 amps

200–240 VAC, 1–phase, 50Hz, 0.8 amps

In North America, a 15–20 amp line. In all other locations, a 10–16 amp line.

Note:Additional outlets my be required, depending on your system configuration. These FX modules may be daisy-chain connected to AC power, with up to seven modules connected to a single AC power outlet. (Every eighth unit in the sortation system requires an AC power outlet.)

Network requirementsThe 3M™ FX Sorter System communicates with the circulation system over a wired Ethernet connection. The Ethernet cable must:

• Meet as a minimum the CAT-5e standard and be terminated with an RJ45 modular plug

• Be long enough to extend from the jack to the FX System Controller Model 2855 with at least two feet (61 cm) of slack

• Be routed away from all traffic areas

Environmental requirements

Indoor environmental requirements

Temperature 50° F to 104° F [10° C to 40° C]

Humidity 20% to 60% relative humidity (non-condensing)

Outdoor environmental requirements (Model 2812)

Temperature –20° F to +120° F [–29° C to 49° C]

Humidity 0% to 85% relative humidity (non-condensing)

78-8129-4938-2B © 3M, 2015. All rights reserved. 15

Page 16: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Module weight

Model Approximate Weight

2810 275 lb [124,7 kg]

2812 275 lb [124,7 kg]

2830 320 lb [145 kg]

2850 130 lb [58,9 kg]

2855 175 lb [79,4 kg]

2860 96 lb [43,5 kg]

2861 150 lb [68,0 kg]

2862 160 lb [72,6 kg]

2863 95 lb [43,1 kg]

2864 150 lb [68,0 kg]

2865 95 lb [43,1 kg]

2899 47 lb [21,3 kg]

Premium bin 75 lbs [34 kg]

78-8129-4938-2B © 3M, 2015. All rights reserved. 16

Page 17: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Module dimensions

Intelligent Return Classic Models

Note:When the 3M Intelligent Return is installed in a wall that is thicker than 14 in [360 mm], it is turned on its frame, which changes the unit's width.

78-8129-4938-2B © 3M, 2015. All rights reserved. 17

42.5 in1080 mm

42.5 in.1080 mm

When wall depth < 14 in [360 mm] When wall depth > 14 in [360 mm]

28 in.711 mm

24.5 in622 mm

20 in

508 mm

25.00 in635 mm

33in

915 mm36 in

33 in838 mm

2810_12_V2_dimensions

Page 18: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Intelligent Return Staff Model 2830

FX Sorter Model 2850

78-8129-4938-2B © 3M, 2015. All rights reserved. 18

2850_dimensions

47 in1194 mm 28 in

711 mm

29 in737 mm

24 in 610 mm

508 mm20 in

787 mm

1016 mm 40 in

940 mm

37 in

1473 mm58 in

1168 mm46 in

2830_V2_Dimensions

Page 19: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

FX System Controller Model 2855

FX Directional Conveyor Model 2860

78-8129-4938-2B © 3M, 2015. All rights reserved. 19

2855_dimensions

21 in 533 mm

65.5 in 1664 mm

20 in 508 mm

2860_dimensions

24 in610 mm

24 in610 mm

36 in914 mm

Page 20: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

FX Ramp Conveyor Model 2861

78-8129-4938-2B © 3M, 2015. All rights reserved. 20

2861_dimensions

24 in.610 mm

48 in.1219 mm

36 in.914 mm

26 in.660 mm

36 in.914 mm

38 in.965 mm

min.

max.

Page 21: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

FX Lift-Gate Conveyor Model 2862

78-8129-4938-2B © 3M, 2015. All rights reserved. 21

2862_dimensions

48 in1219 mm

24 in610 mm

36 in914 mm

Page 22: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

FX Two-Foot Conveyor Model 2863

FX Four-Foot Conveyor Model 2864

78-8129-4938-2B © 3M, 2015. All rights reserved. 22

RD_2800_2864_dimensions

36 in[91 cm]

48 in[122 cm]

24 in[61 cm]

2863_dimensions

24 in610 mm

36 in914 mm

24 in610 mm

Page 23: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Model 2899 Bin

Premium metal bin

78-8129-4938-2B © 3M, 2015. All rights reserved. 23

26 in

660 mm

29.5 in749 mm]

28.5 in

724 mm

2899_dimensions

33 in838 mm

25 in635 mm

35 in889 mm

Premium_Bin_Dimensions

30 in 762 mm

28 in711 mm

30 in762 mm

Page 24: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Wall construction: Models 2810 and 2812This section provides wall construction requirements for 3M Intelligent Return Classic units.

Before beginning new construction or changing an existing structure, contact 3M Library Systems TechnicalService at 1-800-328-0067 (website: http://www.3M.com/library) or your sales representative to:

• Confirm that you have the most recent version of this document.

• Verify that the proposed system can be installed in the planned space.

Front elevation

• The 2810/2812 requires a wall opening 28 inches wide × 21.5 inches high [711 mm × 546 mm].

• The surround adds a 3 in. (760 mm) border around the opening.

• The wall opening requires framing material that will readily accept the surround anchor screws, which cannot be concrete, brick, or rock of any kind. 3M recommends 2 x 6 inch treated wood framing.

• The system can be installed in walls with depths that range from 4 in. (102 mm) to 18 in. (457 mm).

• 3M requires that the bottom of the wall opening be 33 in. (838 mm) from the floor on the staff side of the wall. If the staff and patron sides of the wall are at the same elevation, this will place the shelf at a height of 36 in. (914 mm), which is an ADA recommendation. If they are at different elevations, contact your 3M sales representative or 3M Technical Service to discuss options.

Note: The system requires anopening that complies exactly withthe dimensions listed in the figure. Ifyou plan to finish the opening, therough opening must be large enoughto accommodate the finishedmaterials and still maintain thesedimensions.

78-8129-4938-2B © 3M, 2015. All rights reserved. 24

281x_wall_dimensions

Surround

Fascia

31 in.[787 mm]

24.5 in.[622 mm]

21.5 in.[546 mm]

28 in.[711 mm]

wide

33 in. [838 mm]from floor on staff side

to opening

2 x 6 in. treated wood frame — recommended

(Reference Only

)3M technician installs

High

Outer Edge (Flange)

33.13 in.[842 mm]

26.75 in.[679 mm]

Page 25: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Side elevation

.

Wall thickness and weight bearing capacity• The system can be installed in walls that are between 4 in. to 18. in [10 to 46 cm] thick.

• The wall should be strong enough to bear the weight of the 3M Intelligent Return, which means it should beable to handle the additional 225 lb. [102 kg] when the system is placed on it.

78-8129-4938-2B © 3M, 2015. All rights reserved. 25

33in

915 mm36 in

33 in838 mm

2810-12-V2_side_elevation

Page 26: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Minimum distances between RFID systemsThis section lists minimum distances required between 3M RFID systems in order to avoid RF interference. In some situations, these distances may not be sufficient, though this can only be determined on-site. Specific systems may have additional requirements regarding cable routing, power supplies, other sources of interference and space for clearance for maintenance, workflow, and other considerations. See the sections that address these issues in the applicable Site Planning Guide or Architect/Contractor’s Package

811812813814946

SelfCheck895

2800†3100†

LyngsoeSystems†

877plasticchute

877metalchute

88008900

8900B9900

9100

811812813814946

2 ft.61 cm

2 ft.61 cm

2 ft.61 cm

2 ft.61 cm

2 ft.61 cm

2 ft.61 cm

3 ft.91 cm

8.2 ft.2,5 m

3 ft.91 cm

SelfCheck895

2 ft.61 cm

4ft.**1,2 m

2 ft.61 cm

2 ft.61 cm

2 ft.61 cm

2 ft.61 cm

3 ft.91 cm

8.2 ft.2,5 m

3 ft.91 cm

28003100

2 ft.61 cm

2 ft.61 cm

2 ft.61 cm

2 ft.61 cm

2 ft.61 cm

2 ft.61 cm

3 ft.91 cm

8.2 ft.2,5 m

3 ft.91 cm

LyngsoeSystem

2 ft.61 cm

2 ft.61 cm

2 ft.61 cm

2 ft.61 cm

4 ft.1,2 m

4 ft.1,2 m

3 ft.91 cm

15 ft.4,6 m

3 ft.91 cm

877 plasticchute

2 ft.61 cm

2 ft.61 cm

2 ft.61 cm

4 ft.1,2 m

4 ft.1,2 m

4 ft.1,2 m

4 ft.1,2 m

15 ft.4,6 m

4 ft.1,2 m

877 metalchute

2 ft.61 cm

2 ft.61 cm

2 ft.61 cm

4 ft.1,2 m

4 ft.1,2 m

1 ft.30 cm

3 ft.91 cm

15 ft.4,6 m

3 ft.91 cm

88003 ft.91 cm

3 ft.91 cm

3 ft.91 cm

3 ft.91 cm

4 ft.1,2 m

3 ft.91 cm

3 ft.91 cm

15 ft.4,6 m

3 ft.91 cm

89008900B9900

8.2 ft.2,5 m

8.2 ft.2,5 m

8.2 ft.2,5 m

15 ft.4,6 m

15 ft.4,6 m

15 ft.4,6 m

15 ft.4,6 m

15 ft *4,6 m

15 ft4,6 m

91003 ft.91 cm

3 ft.91 cm

3 ft.91 cm

3 ft.91 cm

4 ft.1,2 m

3 ft.91 cm

3 ft.91 cm

15 ft *4,6 m

5 ft #1,5 m

* Model 8900 systems can be placed closer than 15 feet [4,6 m] apart when they are connected by sync cable. See the discussion in the Model 8900 Architect/Contractor’s Package. Model 8900B and Model 9900 systems, or “mixed” environments that include an 8900B and a 9900 system (which use common electronics), can be placed closer than 15 feet [4,6 m] apart when systems are connected by sync cable. See the discussion in the Model 8900B or Model 9900 Architect/Contractor’s Package.

78-8129-4938-2B © 3M, 2015. All rights reserved. 26

Page 27: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

** Four foot [1,2 m] minimum applies to all 895 pad units and SelfCheck™ units without a cabinet. For SelfCheck™ units enclosed in a cabinet, there are no distance restrictions.

# This restriction can be worked around by creating a single large system by running lattice to lattice cables between “systems.” This combined system cannot exceed eight lattices.

† Measurement is from the RFID reader.

Minimum distances to walls and obstructions• The system requires a minimum of 18 in. [457 mm] between the induction unit and the wall or other

obstructions.

• 3M recommends a minimum of 36 in. [914 mm] between the sorter and the wall or other obstruction.

78-8129-4938-2B © 3M, 2015. All rights reserved. 27

28XX_distance_to_walls

IntelligentReturn18 in

[457 mm]Recommended

18 in[457 mm]

Recommended

Page 28: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Minimum access requirementsThe hallway and access doors between theshipping area where the system is receivedand the room that will house the 3MIntelligent Return and Sorter System mustmeet the specifications shown in the figurein order to move the system into place.

78-8129-4938-2B © 3M, 2015. All rights reserved. 28

Minimum

hall width

requirements:

36 in [914 mm]

Minimum

door width

requirements:

36 in [914 mm]

28XX_minimum_door_hall_req

Page 29: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Install the surroundInstall the surround for the Intelligent Return system fascia.

• Verify that the bottom surface of the surround opening is the correct distance from the ground, which is 33 in. (+/- 0.5 in) [840 mm] from the floor or pavement on the patron side of the wall.

• Use a two-foot level and torpedo level on the surround sill surface to level the surround.

• Fasten the surround securely in place by at least six #8 × 2 in. (three each side) wood screws and flat washers through the surround walls into the surrounding wall studs. Install shims in appropriate locations to maintain the surround position.

78-8129-4938-2B © 3M, 2015. All rights reserved. 29

Page 30: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Insulate the surround of outdoor unitsInsulate the surround of outdoor units.

78-8129-4938-2B © 3M, 2015. All rights reserved. 30

Insulate around surround inside opening.

28xx_insulate_around_surround

Page 31: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Sample configurationsThe information in this section provides insight on the space required for various configurations of the 3M Intelligent Return and Sorter System FX.

Please keep the following in mind:

• Other configurations are possible. The 3M Intelligent Return and Sorter System FX is a flexible system, so there are other ways to arrange the system to meet your needs.

• The information in this section should not be used as a substitute for taking exact measurements and consulting with 3M Technical Service to ensure that adequate space is available and other facility requirements met for the system you intend to install.

Three bin configurationThe illustration at right shows a three binconfiguration with approximate spacerequirements. Please contact 3M TechnicalService before making a final determinationon the space required to install a system.

78-8129-4938-2B © 3M, 2015. All rights reserved. 31

28xx 2850

2899

2899

2899

8 -3-3/4' "[2,53 m]

7 -0[2,13 m]' "

28

55

28xx_V2_FX_3_bins

Page 32: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Three bin configuration with Staff Intelligent ReturnThe illustration at right showsapproximate space requirementsfor a Staff Intelligent Return withsorter and three bins. Pleasecontact 3M Technical Servicebefore making a finaldetermination on the spacerequired to install a system.

Five bin configurationThe following is an illustration of a five bin configuration with approximate space requirements. Please contact 3M Technical Service before making a final determination on the space required to install a system.

78-8129-4938-2B © 3M, 2015. All rights reserved. 32

6'-8"2.03 m

8'-1"2.45 m

2830 2850 2899

2899

2899

285

5

2830_V2_FX_3_bins

2850

2899

28xx 2850

2899

2899 2899

2899

28xx_FX_5_bin

10 -9' "3,27 m

7 -02,13 m' "

285

5

Page 33: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Five bin configuration with Staff Intelligent ReturnThe following illustration shows approximate space requirements for a Staff Intelligent Return with sorters and five bins. Please contact 3M Technical Service before making a final determination on the space required to install a system.

78-8129-4938-2B © 3M, 2015. All rights reserved. 33

6'-8"2.03m

10'-6"3.19m

2830 2850

2899

2899

2850 2899

2899

2899

2830_V2_5_bin_example

2855

Page 34: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Seven bin configurationThe following is an illustration of a seven bin configuration with approximate space requirements. Please contact 3M Technical Service before making a final determination on the space required to install a system.

78-8129-4938-2B © 3M, 2015. All rights reserved. 34

2850

2899

28xx 2850

2899

2899 2899

2899

28xx_7_bin_config

13 -1-3/4' "[4,01 m]

7 -0[2,13 m]' "

285

5

2850

2899

2899

Page 35: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Seven bin configuration with Staff Intelligent ReturnThe following illustration shows approximate space requirements for a Staff Intelligent Return with sorters and seven bins. Please contact 3M Technical Service before making a final determination on the space required to install a system.

78-8129-4938-2B © 3M, 2015. All rights reserved. 35

6'-8"2.03m

12'-11"3.93m

2830 2850

2899

2899

2850 2850

2899

2899

2899

2899

2899

2830_V2_7_bin

Page 36: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Seven bin configuration from two Intelligent ReturnsThe following illustration shows approximate space requirements for sortation to seven bins from two Intelligent Returns. Please contact 3M Technical Service before making a final determination on the space required to install a system.

78-8129-4938-2B © 3M, 2015. All rights reserved. 36

2850 2850 2850

2899 2899 2899

2899 2899 2899

28992860

286028xx

28xx

286

2

[5,23 m]17 -2' "

[2,13 m]7 -0' "

285

5

2863

[3,21 m]10 -6-1/4' "

[1,84 m]6 -0' "

28xx_X2_7_bin

Page 37: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Eleven bin configurationThe following is an illustration of an eleven bin configuration with approximate space requirements. Please contact 3M Technical Service before making a final determination on the space required to install a system.

78-8129-4938-2B © 3M, 2015. All rights reserved. 37

2850 2850 2850 2850 2850

2899 2899 2899 2899 2899

2860

28xx

28xx

2860

2860

2862

2899 2899 2899 2899 2899

2899

2864

16 -1' "[4,90 m]

24 -0' "[7,32 m]

2855

2830

28xx_2830_V2_FX_11_bin

Page 38: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Fifteen bin configurationThe following is an illustration of a fifteen bin configuration with approximate space requirements. Please contact 3M Technical Service before making a final determination on the space required to install a system.

78-8129-4938-2B © 3M, 2015. All rights reserved. 38

17'8"5.40m

27'11"8.50m

286328602860

28602860

28xx

28xx

2850

2899

2899

2850 2850

2899

2899

2899

2899

2899

2850

2899

2899

2850

2899

2899

2850 2850

2899

2899

2899

2899

2830

2855

2862

2862

28xx_2830_V2_FX 15_bin

Page 39: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

Warranty

78-8129-4938-2B © 3M, 2015. All rights reserved. 39

Page 40: 3M™ Intelligent Return Classic and Sorter System FX Architect ...multimedia.3m.com/mws/media/812368O/2800-classic-sorter-syste… · 3M™ Intelligent Return Classic and Sorter

3M™ Intelligent Return Classic and Sorter System FX Architect/Contractor's Package

3M Service

Information to gatherBefore you call, please have the following information available:

• Name, address, and telephone number of your facility

• Model number(s) of equipment you are calling about —and, if applicable, other equipment installed

• Your question(s), or if applicable, a description of the problem or issue you want addressed

3M Service phone numbersFor questions regarding your system, call one of the following numbers.

In the United States In Canada In other countries

1-800-328-0067 English 1-800-268-6235 Français 1-800-567-3193

Call your local 3M office.

3M Library Systems Web SiteThe 3M Library Systems Web site can be located at http://www.3M.com/library.

For additional information in the United States about 3M Library Systems, go to http://www.3M.com/us/library.

3M Library Systems3M Center, Building 225-4N-14 St. Paul, MN 55144-1000www.3M.com/library

78-8129-4938-2B © 3M, 2015. All rights reserved. 40