3m sterilization assurance full line catalog - '+domain …€¦ · · 2015-07-033m...
TRANSCRIPT
3M Sterilization Assurance Full Line CatalogComplete sterilization assurance products
39390 catalog 3.qxd 4/12/02 4:13 PM Page A
Record Keeping 28Record Keeping Software 29Log Books, Envelopes and Record Charts 29 Load Record Cards 30Sterilization Integrator Load Record Card 30Label Gun System 31
Cleaning and Decontamination 32Multi-Enzyme Detergent 33
Sterilization Hardware 34Gas Sterilizers/Aerators 35Aerator 363M™ EtO-Abator System 36Drying Cabinet 37Transfer Cart 37Ethylene Oxide (EO) Gas Cartridges 38Printer Paper 38Packaging 39Ethylene Oxide (EO) Monitoring Badge 39
Index35 40
ContentsIntroduction 2
Biological Indicators 6Rapid Readout Biological Indicators and Test Packs 7Auto-readers 8Biological Indicators and Test Packs 9Biological Indicator Monitoring Starter Kit 10Biological Indicator Incubators 10
Enzymatic Indicators 11Enzymatic Indicators and Challenge Packs 12
Chemical Indicators 13Steam and Ethylene Oxide (EO) Chemical Integrator Test Pack 14Steam Chemical Integrators 15Steam Chemical Indicator-Plus Strips 15Steam Chemical Indicator Strips 16Chemical Indicator Roll–Steam 16Low Temperature Chemical Indicators 17–18Chemical Indicator Roll–Ethylene Oxide (EO) 18Dry Heat Chemical Indicators 19Glutaraldehyde Monitors 20Instrument Protectors 21Sterilization Indicator Labels 21
Bowie-Dick Test Pack and Sheets 22Bowie-Dick Plus Test Pack with Early Warning Test Sheet 23Bowie-Dick Type Test Pack and Sheets 23
Indicator Tapes 24Indicator Tape for Steam Sterilization 25Steam Indicator Tape for Disposable Wraps 26Indicator Tape for Ethylene Oxide (EO) Sterilization 26Indicator Tape Dispensers 27
39390 catalog 3.qxd 4/12/02 4:13 PM Page B
Record Keeping 28Record Keeping Software 29Log Books, Envelopes and Record Charts 29 Load Record Cards 30Sterilization Integrator Load Record Card 30Label Gun System 31
Cleaning and Decontamination 32Multi-Enzyme Detergent 33
Sterilization Hardware 34Gas Sterilizers/Aerators 35Aerator 363M™ EtO-Abator System 36Drying Cabinet 37Transfer Cart 37Ethylene Oxide (EO) Gas Cartridges 38Printer Paper 38Packaging 39Ethylene Oxide (EO) Monitoring Badge 39
Index35 40
ContentsIntroduction 2
Biological Indicators 6Rapid Readout Biological Indicators and Test Packs 7Auto-readers 8Biological Indicators and Test Packs 9Biological Indicator Monitoring Starter Kit 10Biological Indicator Incubators 10
Enzymatic Indicators 11Enzymatic Indicators and Challenge Packs 12
Chemical Indicators 13Steam and Ethylene Oxide (EO) Chemical Integrator Test Pack 14Steam Chemical Integrators 15Steam Chemical Indicator-Plus Strips 15Steam Chemical Indicator Strips 16Chemical Indicator Roll–Steam 16Low Temperature Chemical Indicators 17–18Chemical Indicator Roll–Ethylene Oxide (EO) 18Dry Heat Chemical Indicators 19Glutaraldehyde Monitors 20Instrument Protectors 21Sterilization Indicator Labels 21
Bowie-Dick Test Pack and Sheets 22Bowie-Dick Plus Test Pack with Early Warning Test Sheet 23Bowie-Dick Type Test Pack and Sheets 23
Indicator Tapes 24Indicator Tape for Steam Sterilization 25Steam Indicator Tape for Disposable Wraps 26Indicator Tape for Ethylene Oxide (EO) Sterilization 26Indicator Tape Dispensers 27
39390 catalog 3.qxd 4/12/02 4:13 PM Page B
32
3M Sterilization Assurance
Introduction
Providing a full line of options for sterilization process monitoring.
In today’s economic climate, with tighter health care budgets, the prevention of infection is critical to curbing
the enormous costs associated with surgical site infections. What you do every day as a sterilization health care
professional can help reduce the risk of costly infections.
To determine the effectiveness of the entire sterilization process, 3M provides a complete quality sterilization
monitoring program consisting of five basic steps: Load Control, Pack Control, Equipment Control, Exposure
Control and Record Keeping.
We invite you to look into this comprehensive sterilization monitoring program from the industry leader.
3M has been in the sterilization monitoring industry for more than 40 years. With pioneering efforts in the
development of sterilizers, indicator tapes, and self-contained biological indicators, this comprehensive program
provides time-tested accuracy for sterilization assurance in all areas of monitoring from load control to record
keeping, and has become a model for all other sterilization monitoring systems to follow.
You can’t afford the risk of an undetected sterilization process failure. We’re here to work with you to re-evaluate
products, processes and policies throughout your organization.
Working directly with you.
3M understands the challenges you’re facing in sterilization. Growing concerns about risk management and
health care liability, shrinking budgets and stringent documentation requirements. The need to standardize
policies and procedures for a variety of health care settings and locations.
We’ll work with you to meet the varying needs of your organization...from the high volume of large facilities
to the individualized needs of outpatient surgery centers and primary care clinics.
In today’s health care environment, you need accuracy, credibility and efficiency in all phases of the
sterilization process. 3M stands ready to put our leadership, products and services to work for you.
As a worldwide leader in sterilization assurance, 3M’s comprehensive product line is backed by excellence
in innovation, experience and service.
Steps in the sterilization process.
Sterilization is performed to minimize the risk of surgical site infection by destroying all forms of microorganisms
including bacteria, viruses, spores and fungi on an object. The goal of the sterilization process is to assure that
all surgical instruments are free from contamination before surgery. This helps improve patient outcomes and
protects patients from harm. There are five basic steps in the sterilization process itself: Clean, Prep/Pack, Sterilize,
Store and Issue/Use.
Clean and DecontaminateThe presence of soil or organic material on instruments can reduce disinfection or sterilization effectiveness byencapsulating microorganisms and preventing penetration of the disinfectant or sterilant. In addition, the presence oforganic soil can inactivate some disinfectants. The firststep in the sterilization process, clean and decontaminate,addresses the removal of foreign material and makesinstruments ready for further processing.
Prep and PackPrep and Pack is the next step in the five basic steps of the sterilization process. The effectiveness of thesterilization process depends upon the type of packagingmaterial used and the procedure used for prepping,packaging and loading the items to be sterilized. The proper selection of packaging material and the use of internal and external chemical indicators will help customers identify the effectiveness of this step in the process.
SterilizeIn the third step of the sterilization process, instrumentsare exposed to the actual sterilant (steam, ethylene oxide,etc.) or high level disinfectant (glutaraldehyde, etc.) A check of the sterilizer/processor is required to ensurethat it is functioning properly and that the correct qualityand quantity of sterilant or high level disinfectant is usedand that the correct cycle parameters were chosen. This is done through the use of readings and printouts from the equipment and the proper selection and use ofbiological, enzymatic and chemical indicators.
StoreFirst, instruments are removed from the sterilizer/processor and record documentation is completed. Then, appropriate storage is required to maintain the
integrity of the packaging and level of sterility of theinstrument(s) prior to use. Documentation for eachindividual pack is recommended by AAMI, ASHCSP, AORN and JCAHO to ensure that a load or pack can be identified and found in the event of a recall. Thisdocumentation is part of a total record keeping system.
Issue and UseWhen items are requested for use they are retrieved from storage and checked to ensure that the external pack monitor has reached its endpoint (eg. color change)and then issued for use. At the point of use, internal packmonitors are checked to ensure that sterilization processconditions penetrated to the inside of the pack. Next, the instruments are used and then sent back for cleaningand decontamination.
3M Sterilization Assurance Program
39390 catalog 3.qxd 4/12/02 4:13 PM Page 2
32
3M Sterilization Assurance
Introduction
Providing a full line of options for sterilization process monitoring.
In today’s economic climate, with tighter health care budgets, the prevention of infection is critical to curbing
the enormous costs associated with surgical site infections. What you do every day as a sterilization health care
professional can help reduce the risk of costly infections.
To determine the effectiveness of the entire sterilization process, 3M provides a complete quality sterilization
monitoring program consisting of five basic steps: Load Control, Pack Control, Equipment Control, Exposure
Control and Record Keeping.
We invite you to look into this comprehensive sterilization monitoring program from the industry leader.
3M has been in the sterilization monitoring industry for more than 40 years. With pioneering efforts in the
development of sterilizers, indicator tapes, and self-contained biological indicators, this comprehensive program
provides time-tested accuracy for sterilization assurance in all areas of monitoring from load control to record
keeping, and has become a model for all other sterilization monitoring systems to follow.
You can’t afford the risk of an undetected sterilization process failure. We’re here to work with you to re-evaluate
products, processes and policies throughout your organization.
Working directly with you.
3M understands the challenges you’re facing in sterilization. Growing concerns about risk management and
health care liability, shrinking budgets and stringent documentation requirements. The need to standardize
policies and procedures for a variety of health care settings and locations.
We’ll work with you to meet the varying needs of your organization...from the high volume of large facilities
to the individualized needs of outpatient surgery centers and primary care clinics.
In today’s health care environment, you need accuracy, credibility and efficiency in all phases of the
sterilization process. 3M stands ready to put our leadership, products and services to work for you.
As a worldwide leader in sterilization assurance, 3M’s comprehensive product line is backed by excellence
in innovation, experience and service.
Steps in the sterilization process.
Sterilization is performed to minimize the risk of surgical site infection by destroying all forms of microorganisms
including bacteria, viruses, spores and fungi on an object. The goal of the sterilization process is to assure that
all surgical instruments are free from contamination before surgery. This helps improve patient outcomes and
protects patients from harm. There are five basic steps in the sterilization process itself: Clean, Prep/Pack, Sterilize,
Store and Issue/Use.
Clean and DecontaminateThe presence of soil or organic material on instruments can reduce disinfection or sterilization effectiveness byencapsulating microorganisms and preventing penetration of the disinfectant or sterilant. In addition, the presence oforganic soil can inactivate some disinfectants. The firststep in the sterilization process, clean and decontaminate,addresses the removal of foreign material and makesinstruments ready for further processing.
Prep and PackPrep and Pack is the next step in the five basic steps of the sterilization process. The effectiveness of thesterilization process depends upon the type of packagingmaterial used and the procedure used for prepping,packaging and loading the items to be sterilized. The proper selection of packaging material and the use of internal and external chemical indicators will help customers identify the effectiveness of this step in the process.
SterilizeIn the third step of the sterilization process, instrumentsare exposed to the actual sterilant (steam, ethylene oxide,etc.) or high level disinfectant (glutaraldehyde, etc.) A check of the sterilizer/processor is required to ensurethat it is functioning properly and that the correct qualityand quantity of sterilant or high level disinfectant is usedand that the correct cycle parameters were chosen. This is done through the use of readings and printouts from the equipment and the proper selection and use ofbiological, enzymatic and chemical indicators.
StoreFirst, instruments are removed from the sterilizer/processor and record documentation is completed. Then, appropriate storage is required to maintain the
integrity of the packaging and level of sterility of theinstrument(s) prior to use. Documentation for eachindividual pack is recommended by AAMI, ASHCSP, AORN and JCAHO to ensure that a load or pack can be identified and found in the event of a recall. Thisdocumentation is part of a total record keeping system.
Issue and UseWhen items are requested for use they are retrieved from storage and checked to ensure that the external pack monitor has reached its endpoint (eg. color change)and then issued for use. At the point of use, internal packmonitors are checked to ensure that sterilization processconditions penetrated to the inside of the pack. Next, the instruments are used and then sent back for cleaningand decontamination.
3M Sterilization Assurance Program
39390 catalog 3.qxd 4/12/02 4:13 PM Page 2
54
3M Sterilization Education Programs
Continuing education has become increasingly important in many professions and nowhere is it more
critical than in the health care arena. With increasing demands on limited resources, access to educational
programs is often reduced or restricted. 3M Health Care has a long-standing tradition of commitment to
education and we are proud to be able to offer you a full education continuum.
We recognize that people are individuals with different learning styles and abilities. With this in mind,
we have put together a comprehensive range of educational opportunities from which you may select;
those that are appropriate to the individuals within your unit. If you would like further details of any
of these programs, please contact the 3M Health Care Customer Helpline at 1-800-228-3957.
The following is a sample of the full range of 3M’s educational programs and materials for the infection
control, operating room and central supply personnel within your facility.
Examples of 3M Sterilization Assurance Educational Programs and Materials
Sterilization Issues Covering the latest developments in infection control and sterilization.and Answers Course
Infection Control Rounds An educational publication featuring articles on infection control and sterilization.
3M Sterilization Helping meet local educational objectives by organizing speakers Speaker Program for specialized program topics.
In-Service Videos An extensive video library, making in-service training easier for your organization.
Interactive Education CD-ROM programs that facilitate training on best practice guidelines for infection prevention.
Purdue/IAHCSMM A bimonthly educational publication in Health Care Purchasing News trade journal and IAHCSMM newsletters, sponsored by 3M.
3M Sterilization Assurance Program continued
An undetected sterilization process failure can put patients, staff and the financial health of your facility at risk.
Additional costs associated with postoperative infections, and other health care liabilities, make the implementation
of a sterilization process monitoring program an extremely critical practice for all health care facilities. The 3M
Sterilization Assurance Program is a comprehensive and practical approach to sterilization monitoring procedures
and methods that you can count on to reduce your risk of an undetected sterilization process failure.
The 3M Sterilization Assurance Program is the most comprehensive sterilization monitoring system ever developed.
And because the products are designed to monitor the sterilizer, as well as every load and every pack, the 3M
Sterilization Assurance Program provides a high level of confidence that sterile conditions have been met. The days
of waiting for an accurate sterilization reading are gone.
The 3M Sterilization Assurance Program offers:
Rapid Release of Critical DevicesA series of checks and balances makes it possible to verify if conditions for sterilization of implantableshave been achieved.
Elimination of RecallsBecause the 3M Sterilization Assurance Program monitors the sterilizer as well as each pack, you’ll know if conditions for sterilization have been met and the load can be released from sterile processing.
Less Purchasing of InstrumentsYou can manage your current inventory more efficiently,potentially saving your health care facility a substantialamount of money.
Reduction in the Risk of InfectionNonsterile instruments and implantables are a probablecause of surgical wound infections. The 3M SterilizationAssurance Program signals your staff immediately to sterilization process problems that could lead tononsterile medical devices.
Reduction and Control of Sterilizer DowntimeYou can be alerted to problems before they becomeserious—enabling you to schedule service at a timethat’s convenient.
Documentation to Help Meet Accreditation RequirementsThe 3M Sterilization Assurance Program record keeping system enables you to record and store all sterilization data in an easily retrievable format and meet recommended standards and practices.
39390 catalog 3.qxd 4/12/02 4:13 PM Page 4
54
3M Sterilization Education Programs
Continuing education has become increasingly important in many professions and nowhere is it more
critical than in the health care arena. With increasing demands on limited resources, access to educational
programs is often reduced or restricted. 3M Health Care has a long-standing tradition of commitment to
education and we are proud to be able to offer you a full education continuum.
We recognize that people are individuals with different learning styles and abilities. With this in mind,
we have put together a comprehensive range of educational opportunities from which you may select;
those that are appropriate to the individuals within your unit. If you would like further details of any
of these programs, please contact the 3M Health Care Customer Helpline at 1-800-228-3957.
The following is a sample of the full range of 3M’s educational programs and materials for the infection
control, operating room and central supply personnel within your facility.
Examples of 3M Sterilization Assurance Educational Programs and Materials
Sterilization Issues Covering the latest developments in infection control and sterilization.and Answers Course
Infection Control Rounds An educational publication featuring articles on infection control and sterilization.
3M Sterilization Helping meet local educational objectives by organizing speakers Speaker Program for specialized program topics.
In-Service Videos An extensive video library, making in-service training easier for your organization.
Interactive Education CD-ROM programs that facilitate training on best practice guidelines for infection prevention.
Purdue/IAHCSMM A bimonthly educational publication in Health Care Purchasing News trade journal and IAHCSMM newsletters, sponsored by 3M.
3M Sterilization Assurance Program continued
An undetected sterilization process failure can put patients, staff and the financial health of your facility at risk.
Additional costs associated with postoperative infections, and other health care liabilities, make the implementation
of a sterilization process monitoring program an extremely critical practice for all health care facilities. The 3M
Sterilization Assurance Program is a comprehensive and practical approach to sterilization monitoring procedures
and methods that you can count on to reduce your risk of an undetected sterilization process failure.
The 3M Sterilization Assurance Program is the most comprehensive sterilization monitoring system ever developed.
And because the products are designed to monitor the sterilizer, as well as every load and every pack, the 3M
Sterilization Assurance Program provides a high level of confidence that sterile conditions have been met. The days
of waiting for an accurate sterilization reading are gone.
The 3M Sterilization Assurance Program offers:
Rapid Release of Critical DevicesA series of checks and balances makes it possible to verify if conditions for sterilization of implantableshave been achieved.
Elimination of RecallsBecause the 3M Sterilization Assurance Program monitors the sterilizer as well as each pack, you’ll know if conditions for sterilization have been met and the load can be released from sterile processing.
Less Purchasing of InstrumentsYou can manage your current inventory more efficiently,potentially saving your health care facility a substantialamount of money.
Reduction in the Risk of InfectionNonsterile instruments and implantables are a probablecause of surgical wound infections. The 3M SterilizationAssurance Program signals your staff immediately to sterilization process problems that could lead tononsterile medical devices.
Reduction and Control of Sterilizer DowntimeYou can be alerted to problems before they becomeserious—enabling you to schedule service at a timethat’s convenient.
Documentation to Help Meet Accreditation RequirementsThe 3M Sterilization Assurance Program record keeping system enables you to record and store all sterilization data in an easily retrievable format and meet recommended standards and practices.
39390 catalog 3.qxd 4/12/02 4:13 PM Page 4
Load Con t ro l
7
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Load ControlThe sterilization reliability that only a biological indicator can deliver
Biological Indicators
• Results in one hour (1291) or three hours (1292)
• Test packs present a challenge to the sterilization process as do the AAMIrecommended packs
• Make decisions and take appropriate action before surgery
• Every load monitoring and quarantining can eliminate recalls
• The Attest rapid readout biological monitoring system can help reduce the costs associated with fighting infections—a cost measured in both dollars and time spent
• Malfunctioning sterilizers can be repaired and put back into service quickly
3M™ Attest™ Rapid Readout Biological Indicator for 270°F/132°C Gravity Displacement Steam Sterilizers
Cat. # Description Packaging Shipping
1291* Steam Biological Indicator 50 each/box 4 boxes/case
3M™ Attest™ Rapid Readout Biological Indicators for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizers
Cat. # Description Packaging Shipping
1292* Steam Biological Indicator 50 each/box 4 boxes/case
1296* Steam Biological Test Pack (25 controls) 25 packs/box 1 box/case
1296F* Steam Biological Test Pack (5 controls) 25 packs/box 1 box/case
*Must be used in conjunction with 3M™ Attest™ Model 190 or 290 Auto-reader
Rapid Readout Biological Indicators and Test Packs
1
39390 catalog 3.qxd 4/12/02 4:13 PM Page 6
Load Con t ro l
7
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Load ControlThe sterilization reliability that only a biological indicator can deliver
Biological Indicators
• Results in one hour (1291) or three hours (1292)
• Test packs present a challenge to the sterilization process as do the AAMIrecommended packs
• Make decisions and take appropriate action before surgery
• Every load monitoring and quarantining can eliminate recalls
• The Attest rapid readout biological monitoring system can help reduce the costs associated with fighting infections—a cost measured in both dollars and time spent
• Malfunctioning sterilizers can be repaired and put back into service quickly
3M™ Attest™ Rapid Readout Biological Indicator for 270°F/132°C Gravity Displacement Steam Sterilizers
Cat. # Description Packaging Shipping
1291* Steam Biological Indicator 50 each/box 4 boxes/case
3M™ Attest™ Rapid Readout Biological Indicators for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizers
Cat. # Description Packaging Shipping
1292* Steam Biological Indicator 50 each/box 4 boxes/case
1296* Steam Biological Test Pack (25 controls) 25 packs/box 1 box/case
1296F* Steam Biological Test Pack (5 controls) 25 packs/box 1 box/case
*Must be used in conjunction with 3M™ Attest™ Model 190 or 290 Auto-reader
Rapid Readout Biological Indicators and Test Packs
1
39390 catalog 3.qxd 4/12/02 4:13 PM Page 6
Load Con t ro l
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BI
OLOG
ICAL
INDI
CATO
RS
9
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Biological Indicators and Test Packs
• Biological indicator vials are easy to use and interpret with visual colorreadout in 24 hours (1261) or 48 hours (1262/1264)
• Test packs present a challenge to the sterilization process as do the AAMIrecommended test packs
• Each test pack contains an Attest 1262 or 1264 biological indicator
3M™ Attest™ Biological Indicators for 270°F/132°C Gravity Displacement Steam Sterilizers
Cat. # Description Packaging Shipping
1261 Steam Biological Indicator 100 each/box 4 boxes/case
1261P Steam Biological Indicator 25 each/box 4 boxes/case
3M™ Attest™ Biological Indicators for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizers
Cat. # Description Packaging Shipping
1262 Steam Biological Indicator 100 each/box 4 boxes/case
1262P Steam Biological Indicator 25 each/box 4 boxes/case
1276 Steam Biological Test Pack 25 each/box 1 box/case(25 controls/box)
1276F Steam Biological Test Pack 25 each/box 1 box/case(5 controls/box)
3M™ Attest™ Steam-Plus Test Pack
Each pack consists of an Attest 1262 Biological Indicator and a 3M™ Comply™ (SteriGage™)Steam Chemical Integrator. For use in every load.
Cat. # Description Packaging Shipping
41380 Steam-Plus Test Pack 16 each/box 4 boxes/case(4 controls/box)
3M™ Attest™ Biological Indicators for Ethylene Oxide (EO)
Cat. # Description Packaging Shipping
1264 Ethylene Oxide (EO) Biological Indicator 100 each/box 4 boxes/case
1264P Ethylene Oxide (EO) Biological Indicator 25 each/box 4 boxes/case
1278 EO Test Pack (25 controls) 25 each/box 2 boxes/case
1278F EO Test Pack (5 controls) 25 each/box 2 boxes/case
2
Load Con t ro l
8
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BI
OLOG
ICAL
INDI
CATO
RS
• 14-vial capacity, 60˚C steam incubation temperature
• Built-in fluorescent reader with manual calibration and readout in 1 or 3 hours
• For use with 3M™ Attest™ Rapid Readout Biological Indicators
3M™ Attest™ 190 Auto-reader
Cat. # Description Packaging Shipping
190* 120V nominal voltage required; 108-132V 1 unit/box 1 box/caseacceptable voltage range
78-8078-7349-8 UV Bulb and Starter Kit (only sold direct) - 1 each/case
*Only available from your 3M sales representative.
• The Attest 290 auto-reader does not require time-consuming calibration
• Audible alarm sounds for improved monitoring
• Does not require any routine maintenance
• For use with 3M™ Attest™ Rapid Readout Biological Indicators
3M™ Attest™ 290 Auto-reader
Cat. # Description Packaging Shipping
290* 120V nominal voltage required; 108-132V 1 unit/box 1 box/caseacceptable voltage range
78-2007-2981-5 Power cord for Attest 290 auto-reader 1 ea/case
*Only available from your 3M sales representative.
Auto-readers
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
6
3
5
4
39390 catalog 3.qxd 4/12/02 4:14 PM Page 8
Load Con t ro l
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BI
OLOG
ICAL
INDI
CATO
RS
9
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Biological Indicators and Test Packs
• Biological indicator vials are easy to use and interpret with visual colorreadout in 24 hours (1261) or 48 hours (1262/1264)
• Test packs present a challenge to the sterilization process as do the AAMIrecommended test packs
• Each test pack contains an Attest 1262 or 1264 biological indicator
3M™ Attest™ Biological Indicators for 270°F/132°C Gravity Displacement Steam Sterilizers
Cat. # Description Packaging Shipping
1261 Steam Biological Indicator 100 each/box 4 boxes/case
1261P Steam Biological Indicator 25 each/box 4 boxes/case
3M™ Attest™ Biological Indicators for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizers
Cat. # Description Packaging Shipping
1262 Steam Biological Indicator 100 each/box 4 boxes/case
1262P Steam Biological Indicator 25 each/box 4 boxes/case
1276 Steam Biological Test Pack 25 each/box 1 box/case(25 controls/box)
1276F Steam Biological Test Pack 25 each/box 1 box/case(5 controls/box)
3M™ Attest™ Steam-Plus Test Pack
Each pack consists of an Attest 1262 Biological Indicator and a 3M™ Comply™ (SteriGage™)Steam Chemical Integrator. For use in every load.
Cat. # Description Packaging Shipping
41380 Steam-Plus Test Pack 16 each/box 4 boxes/case(4 controls/box)
3M™ Attest™ Biological Indicators for Ethylene Oxide (EO)
Cat. # Description Packaging Shipping
1264 Ethylene Oxide (EO) Biological Indicator 100 each/box 4 boxes/case
1264P Ethylene Oxide (EO) Biological Indicator 25 each/box 4 boxes/case
1278 EO Test Pack (25 controls) 25 each/box 2 boxes/case
1278F EO Test Pack (5 controls) 25 each/box 2 boxes/case
2
Load Con t ro l
8
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BI
OLOG
ICAL
INDI
CATO
RS
• 14-vial capacity, 60˚C steam incubation temperature
• Built-in fluorescent reader with manual calibration and readout in 1 or 3 hours
• For use with 3M™ Attest™ Rapid Readout Biological Indicators
3M™ Attest™ 190 Auto-reader
Cat. # Description Packaging Shipping
190* 120V nominal voltage required; 108-132V 1 unit/box 1 box/caseacceptable voltage range
78-8078-7349-8 UV Bulb and Starter Kit (only sold direct) - 1 each/case
*Only available from your 3M sales representative.
• The Attest 290 auto-reader does not require time-consuming calibration
• Audible alarm sounds for improved monitoring
• Does not require any routine maintenance
• For use with 3M™ Attest™ Rapid Readout Biological Indicators
3M™ Attest™ 290 Auto-reader
Cat. # Description Packaging Shipping
290* 120V nominal voltage required; 108-132V 1 unit/box 1 box/caseacceptable voltage range
78-2007-2981-5 Power cord for Attest 290 auto-reader 1 ea/case
*Only available from your 3M sales representative.
Auto-readers
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
6
3
5
4
39390 catalog 3.qxd 4/12/02 4:14 PM Page 8
Enzymatic Indicators
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Load Con t ro l
10
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BI
OLOG
ICAL
INDI
CATO
RS
FPOneed family shot or ps label
Everything you need for effective monitoring of the steam sterilization process.
3M™ Attest™ Biological Indicator Monitoring Starter Kit
Consists of one roll of 3M™ Comply™ 1222-6N Indicator Tape, one box of 3M™
Attest™ 1262P Biological Indicators, one 3M™ Attest™ 116 Incubator, one bag of 3M™ Comply™ 1243B Chemical Integrators, one 3M™ 1266 Log Book,in-service video and wall chart.
Cat. # Description Packaging Shipping
115 3M Attest Monitoring Kit 1 each/box 1 box/case
A full line of Attest incubators provide optimal conditions for accurate readout of Attest biological indicators.
• Convenient, 14- or 28-vial capacity
• Dry-block design pre-set to proper incubation temperature
3M™ Attest™ Biological Indicator Incubators
Cat. # Description Packaging Shipping
116 14-vial (round); 56˚C (Steam); 120 nominal voltage required; 1 each/box 1 box/case90–132V acceptable
117 14-vial (round); 37˚C (EO); 120 nominal voltage required; 1 each/box 1 box/case90–132V acceptable
126 28-vial (2-tier); 56˚C (Steam); 120 nominal voltage required; 1 each/box 1 box/case90–132V acceptable
127 28-vial (2-tier); 37˚C (EO); 120 nominal voltage required; 1 each/box 1 box/case90–132V acceptable
130 28-vial (2-tier); 37˚C/56˚C (EO & Steam); 120 nominal 1 each/box 1 box/casevoltage required; 90–132V acceptable
Biological Indicator Monitoring Starter Kit
7
Biological Indicator Incubators
8
39390 catalog 3.qxd 4/12/02 4:14 PM Page 10
Enzymatic Indicators
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Load Con t ro l
10
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BI
OLOG
ICAL
INDI
CATO
RS
FPOneed family shot or ps label
Everything you need for effective monitoring of the steam sterilization process.
3M™ Attest™ Biological Indicator Monitoring Starter Kit
Consists of one roll of 3M™ Comply™ 1222-6N Indicator Tape, one box of 3M™
Attest™ 1262P Biological Indicators, one 3M™ Attest™ 116 Incubator, one bag of 3M™ Comply™ 1243B Chemical Integrators, one 3M™ 1266 Log Book,in-service video and wall chart.
Cat. # Description Packaging Shipping
115 3M Attest Monitoring Kit 1 each/box 1 box/case
A full line of Attest incubators provide optimal conditions for accurate readout of Attest biological indicators.
• Convenient, 14- or 28-vial capacity
• Dry-block design pre-set to proper incubation temperature
3M™ Attest™ Biological Indicator Incubators
Cat. # Description Packaging Shipping
116 14-vial (round); 56˚C (Steam); 120 nominal voltage required; 1 each/box 1 box/case90–132V acceptable
117 14-vial (round); 37˚C (EO); 120 nominal voltage required; 1 each/box 1 box/case90–132V acceptable
126 28-vial (2-tier); 56˚C (Steam); 120 nominal voltage required; 1 each/box 1 box/case90–132V acceptable
127 28-vial (2-tier); 37˚C (EO); 120 nominal voltage required; 1 each/box 1 box/case90–132V acceptable
130 28-vial (2-tier); 37˚C/56˚C (EO & Steam); 120 nominal 1 each/box 1 box/casevoltage required; 90–132V acceptable
Biological Indicator Monitoring Starter Kit
7
Biological Indicator Incubators
8
39390 catalog 3.qxd 4/12/02 4:14 PM Page 10
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Load Con t ro l
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZY
MAT
IC IN
DICA
TORS
BIOL
OGIC
ALIN
DICA
TORS
Enzymatic Indicators and Challenge Packs
These indicators and challenge packs are used to monitor steam sterilization cycles.
• Requires no incubation and no other instrumentation to interpret results
• Easy-to-read results in 20 seconds
• Reusable challenge pack (use up to 20 times)
3M™ Rapid Enzymatic Indicators for 250˚F/121˚ Displacement and 273˚/134˚ Vacuum Assisted Gravity Steam Sterilization
Cat. # Description Packaging Shipping
2482 Enzymatic Indicator 100 test units, indicator 1 box/casesolution/box
2482F Enzymatic Indicator 50 test units, 1 box/caseindicator solution/box
2482T Enzymatic Indicator 10 test units, 1 box/caseindicator solution/box
3M™ Rapid Enzymatic Indicators and Challenge Packs for 273˚/134˚ Vacuum Assisted Steam Sterilization
Cat. # Description Packaging Shipping
2486 Enzymatic Indicator 4 challenge packs, 100 test units, 1 box/caseand Challenge Packs indicator solution/box
2486F Enzymatic Indicator 2 challenge packs, 50 test units 1 box/caseand Challenge Packs indicator solution/box
2483 Challenge Packs 5 challenge packs/box 1 box/case
9
12
Chemical Indicators
39390 catalog 3.qxd 4/12/02 4:15 PM Page 12
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Load Con t ro l
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZY
MAT
IC IN
DICA
TORS
BIOL
OGIC
ALIN
DICA
TORS
Enzymatic Indicators and Challenge Packs
These indicators and challenge packs are used to monitor steam sterilization cycles.
• Requires no incubation and no other instrumentation to interpret results
• Easy-to-read results in 20 seconds
• Reusable challenge pack (use up to 20 times)
3M™ Rapid Enzymatic Indicators for 250˚F/121˚ Displacement and 273˚/134˚ Vacuum Assisted Gravity Steam Sterilization
Cat. # Description Packaging Shipping
2482 Enzymatic Indicator 100 test units, indicator 1 box/casesolution/box
2482F Enzymatic Indicator 50 test units, 1 box/caseindicator solution/box
2482T Enzymatic Indicator 10 test units, 1 box/caseindicator solution/box
3M™ Rapid Enzymatic Indicators and Challenge Packs for 273˚/134˚ Vacuum Assisted Steam Sterilization
Cat. # Description Packaging Shipping
2486 Enzymatic Indicator 4 challenge packs, 100 test units, 1 box/caseand Challenge Packs indicator solution/box
2486F Enzymatic Indicator 2 challenge packs, 50 test units 1 box/caseand Challenge Packs indicator solution/box
2483 Challenge Packs 5 challenge packs/box 1 box/case
9
12
Chemical Indicators
39390 catalog 3.qxd 4/12/02 4:15 PM Page 12
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Load Con t ro l
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHEM
ICAL
INDI
CATO
RS
ENZY
MAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
3M Comply chemical integrators offer an immediate, accurate and easy-to-readmethod of monitoring sterilization process conditions inside each pack.
• Available for steam sterilization cycles
• “Moving front” style has accept/reject readout for instant results withoutinterpretation, convenient small size for all packs, and optional extendersavailable for easy retrieval from inner packs
• Immediately identify problems in specific packs
• Safe, non-toxic chemicals; no worry of contamination or transfer to sterile items
3M™ Comply™ (SteriGage™) Steam Chemical Integrators
Cat. # Description Packaging Shipping
1243A Steam Chemical Integrator; moving front; 500 each/bag 2 bags/case2 in. x 3/4 in. (5,1 cm x 1,9 cm)
1243B Steam Chemical Integrator; moving front; 100 each/bag 10 bags/case2 in. x 3/4 in. (5,1 cm x 1,9 cm)
1243E Steam Chemical Integrator; moving front with extender; 1000 each/bag 1 bag/case9 in. x 3/8 in. (22,9 cm x 1,0 cm)
1240E Extender only; 2500 each/bag 2 bags/case7-1/2 in. x 3/8 in. (19,1 cm x 1,0 cm)
Steam Chemical Integrators
Steam Chemical Indicator-Plus Strips
Each strip has two purple ink bars that are sterilantspecific and change color in sequence during exposureto saturated steam. A clear protective coating over theink bars prevents the ink from touching items beingsterilized.
3M™ Comply™ Steam Chemical Indicator-Plus Strips
Cat. # Description Packaging Shipping
00117 Short Form—270˚F Indicator 200 each/box 20 boxes/case5/8 in. x 4-1/4 in. (1,5 cm x 10,8 cm) for use in 270˚F vacuum-assisted and gravity sterilizers
00118 Long Form—270˚F Indicator 5/8 in. x 7-3/8 in.; 200 each/box 20 boxes/case5/8 in. x 7-3/8 in. (1,5 cm x 18,7 cm)for use in 270˚F vacuum-assisted and gravity sterilizers
00119 250˚F Indicator, 5/8 in. x 4-1/4 in.; 200 each/box 20 boxes/case5/8 in. x 4-1/4 in. (1,5 cm x 10,8 cm)for use in 250˚F gravity sterilizers
13
14
Pack Con t ro l
15
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHEM
ICAL
INDI
CATO
RS
ENZY
MAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
12
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Steam Chemical Integrator Test Pack
Pack consists of a 3M™ Comply™ (SteriGage™) Steam Chemical Integrator in a small test pack of porous substrate with a moisture impervious, quality CSR wrap.
• Test packs present a challenge to the sterilization process as do the AAMIrecommended packs
3M™ Comply™ (SteriGage™) Steam Chemical Integrator Test Pack
Cat. # Description Packaging Shipping
41360 Pack with Comply (SteriGage) Steam 16 packs/box 4 boxes/caseChemical Integrator
10
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
EO Chemical Integrator Test Pack
Pack consists of a 3M™ Comply™ (SteriGage™) EO Chemical Integrator inside aprecisely engineered pack. For use in every load of EO/HCFC gas mixtures inconjunction with a biological indicator test pack.
• Test packs present a challenge to the sterilization process as do the AAMIrecommended packs
3M™ Comply™ (SteriGage™) EO Chemical Integrator Test Pack
Cat. # Description Packaging Shipping
45260 Pack with Comply (SteriGage) 16 packs/box 4 boxes/caseEO Chemical Integrator
11
39390 catalog 3.qxd 4/12/02 4:15 PM Page 14
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Load Con t ro l
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHEM
ICAL
INDI
CATO
RS
ENZY
MAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
3M Comply chemical integrators offer an immediate, accurate and easy-to-readmethod of monitoring sterilization process conditions inside each pack.
• Available for steam sterilization cycles
• “Moving front” style has accept/reject readout for instant results withoutinterpretation, convenient small size for all packs, and optional extendersavailable for easy retrieval from inner packs
• Immediately identify problems in specific packs
• Safe, non-toxic chemicals; no worry of contamination or transfer to sterile items
3M™ Comply™ (SteriGage™) Steam Chemical Integrators
Cat. # Description Packaging Shipping
1243A Steam Chemical Integrator; moving front; 500 each/bag 2 bags/case2 in. x 3/4 in. (5,1 cm x 1,9 cm)
1243B Steam Chemical Integrator; moving front; 100 each/bag 10 bags/case2 in. x 3/4 in. (5,1 cm x 1,9 cm)
1243E Steam Chemical Integrator; moving front with extender; 1000 each/bag 1 bag/case9 in. x 3/8 in. (22,9 cm x 1,0 cm)
1240E Extender only; 2500 each/bag 2 bags/case7-1/2 in. x 3/8 in. (19,1 cm x 1,0 cm)
Steam Chemical Integrators
Steam Chemical Indicator-Plus Strips
Each strip has two purple ink bars that are sterilantspecific and change color in sequence during exposureto saturated steam. A clear protective coating over theink bars prevents the ink from touching items beingsterilized.
3M™ Comply™ Steam Chemical Indicator-Plus Strips
Cat. # Description Packaging Shipping
00117 Short Form—270˚F Indicator 200 each/box 20 boxes/case5/8 in. x 4-1/4 in. (1,5 cm x 10,8 cm) for use in 270˚F vacuum-assisted and gravity sterilizers
00118 Long Form—270˚F Indicator 5/8 in. x 7-3/8 in.; 200 each/box 20 boxes/case5/8 in. x 7-3/8 in. (1,5 cm x 18,7 cm)for use in 270˚F vacuum-assisted and gravity sterilizers
00119 250˚F Indicator, 5/8 in. x 4-1/4 in.; 200 each/box 20 boxes/case5/8 in. x 4-1/4 in. (1,5 cm x 10,8 cm)for use in 250˚F gravity sterilizers
13
14
Pack Con t ro l
15
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHEM
ICAL
INDI
CATO
RS
ENZY
MAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
12
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Steam Chemical Integrator Test Pack
Pack consists of a 3M™ Comply™ (SteriGage™) Steam Chemical Integrator in a small test pack of porous substrate with a moisture impervious, quality CSR wrap.
• Test packs present a challenge to the sterilization process as do the AAMIrecommended packs
3M™ Comply™ (SteriGage™) Steam Chemical Integrator Test Pack
Cat. # Description Packaging Shipping
41360 Pack with Comply (SteriGage) Steam 16 packs/box 4 boxes/caseChemical Integrator
10
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
EO Chemical Integrator Test Pack
Pack consists of a 3M™ Comply™ (SteriGage™) EO Chemical Integrator inside aprecisely engineered pack. For use in every load of EO/HCFC gas mixtures inconjunction with a biological indicator test pack.
• Test packs present a challenge to the sterilization process as do the AAMIrecommended packs
3M™ Comply™ (SteriGage™) EO Chemical Integrator Test Pack
Cat. # Description Packaging Shipping
45260 Pack with Comply (SteriGage) 16 packs/box 4 boxes/caseEO Chemical Integrator
11
39390 catalog 3.qxd 4/12/02 4:15 PM Page 14
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Pack Con t ro l
17
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHEM
ICAL
INDI
CATO
RS
ENZY
MAT
IC IN
DICA
TORS
BI
OLOG
ICAL
INDI
CATO
RSP ack Con t ro l
16
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZY
MAT
IC IN
DICA
TORS
BI
OLOG
ICAL
INDI
CATO
RS
Single use chemical indicator for use in the Steris® System 1 processor. Indicator provides assurance that items have been exposed to the appropriateconcentration of sterilant. Indicator changes from red (unprocessed) to green(processed) color for easy interpretation. Large size and distinct color for easyretrieval of the indicator from processor.
3M™ Comply™ Liquid Peracetic Acid Chemical Indicator
Cat. # Description Packaging Shipping
1249 Comply Liquid Peracetic Acid Chemical Indicator 50 items/pouch 4 pouches/case1-3/4 in. x 1-3/4 in. (4,4 cm x 4,4 cm)
An internal pack chemical indicator for use in STERRAD® SterilizationProcesses (models 100, 100S and 50). The indicator provides assurance thatitems inside a pack have been exposed to sterilant. Indicator changes from blueto pink when exposed to vapor hydrogen peroxide. Indicator color does not fadewhen exposed to light.
3M™ Comply™ Gas Plasma Chemical Indicator Strip
Cat. # Description Packaging Shipping
1248 Comply Gas Plasma Chemical Indicator Strip 250 each/box 4 boxes/caseStrip; 13/16 in. x 4 in. (2,0 cm x 10 cm)
3M™ Comply™ Chemical Integrators offer an immediate, accurate and easy-to-read method of monitoring sterilization process conditions inside each pack.
• Available for EO/HCFC gas mixture sterilization cycles.
• “Moving front” style has accept/reject readout for instant results withoutinterpretation, convenient small size for all packs, and optional extendersavailable for easy retrieval from inner packs.
• Immediately identify problems in specific packs.
• Safe, non-toxic chemicals; no worry of contamination or transfer to sterile items.
3M™ Comply™ (SteriGage™) EO Chemical Integrators
Cat. # Description Packaging Shipping
1244A EO Chemical Integrator; moving front; for gas 500 each/bag 2 bags/casemixture sterilizers; 2 in. x 3/4 in. (5,1 cm x 1,9 cm)
1244B EO Chemical Integrator; moving front; for gas 100 each/bag 10 bags/casemixture sterilizers; 2 in. x 3/4 in. (5,1 cm x 1,9 cm)
1244E EO Chemical Integrator; moving front with extender; 1000 each/bag 1 bag/casefor gas mixture sterilizers; 9 in. x 3/8 in. (22,9 cm x 1,0 cm)
1240E Extender only; 2500 each/bag 2 bags/case7-1/2 in. x 3/8 in. (19,1 cm x 1,0 cm)
Low Temperature Chemical Indicators
18
16
17
Steam Chemical Indicator Strips
14
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
15
Chemical Indicator Roll
Chemical indicators for steam in a roll. The chemical indicator lines will turndark brown when exposed to steam.
3M™ Comply™ Indicator Roll*
Cat. # Description Packaging Shipping
1201** Steam (60 yards) 10 rolls/box 1 box/case
*Contains Dry Natural Rubber**Can be used with 3M tape dispenser 1206 (see page 27 )
For use in all steam sterilizers. Long stripe of chemicalindicator ink printed on perforated-style strip. Allowsfull- or half-length use for different pack sizes. Utilizesdistinct color change to indicate process results.Indicator changes color from white to dark brown/black(dark or darker than the color block located in center ofstrip) when exposed to steam sterilization conditions.
3M™ Comply™ Steam Chemical Indicator Strip
Cat. # Description Packaging Shipping
1250 Steam Chemical Indicator Strip 240 each/box 8 boxes/case5/8 in. x 8 in. (1,5 cm x 20 cm)
For use in all steam sterilizers. Chemical indicatorprinted as block on one end of short or long strip.Indicator changes color to dark brown/black (blockturns as dark or darker than a color standard) whenexposed to steam sterilization conditions.
3M™ Comply™ Steam Chemical Indicator Strips
Cat. # Description Packaging Shipping
00107 Long Form, 250 each/box 20 boxes/case5/8 in. x 8-1/2 in. (1,5 cm x 22 cm)
00107A Long Form—Economy Pack 1000 each/box 4 boxes/case5/8 in. x 8-1/2 in. (1,5 cm x 22 cm)
00109 Short Form, 250 each/box 20 boxes/case5/8 in. x 4-1/4 in. (1,5 cm x 11 cm)
00109A Short Form—Economy Pack 1000 each/box 4 boxes/case5/8 in. x 4-1/4 in. 1,5 cm x 11 cm)
39390 catalog 3.qxd 4/12/02 4:15 PM Page 16
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Pack Con t ro l
17
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHEM
ICAL
INDI
CATO
RS
ENZY
MAT
IC IN
DICA
TORS
BI
OLOG
ICAL
INDI
CATO
RSP ack Con t ro l
16
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZY
MAT
IC IN
DICA
TORS
BI
OLOG
ICAL
INDI
CATO
RS
Single use chemical indicator for use in the Steris® System 1 processor. Indicator provides assurance that items have been exposed to the appropriateconcentration of sterilant. Indicator changes from red (unprocessed) to green(processed) color for easy interpretation. Large size and distinct color for easyretrieval of the indicator from processor.
3M™ Comply™ Liquid Peracetic Acid Chemical Indicator
Cat. # Description Packaging Shipping
1249 Comply Liquid Peracetic Acid Chemical Indicator 50 items/pouch 4 pouches/case1-3/4 in. x 1-3/4 in. (4,4 cm x 4,4 cm)
An internal pack chemical indicator for use in STERRAD® SterilizationProcesses (models 100, 100S and 50). The indicator provides assurance thatitems inside a pack have been exposed to sterilant. Indicator changes from blueto pink when exposed to vapor hydrogen peroxide. Indicator color does not fadewhen exposed to light.
3M™ Comply™ Gas Plasma Chemical Indicator Strip
Cat. # Description Packaging Shipping
1248 Comply Gas Plasma Chemical Indicator Strip 250 each/box 4 boxes/caseStrip; 13/16 in. x 4 in. (2,0 cm x 10 cm)
3M™ Comply™ Chemical Integrators offer an immediate, accurate and easy-to-read method of monitoring sterilization process conditions inside each pack.
• Available for EO/HCFC gas mixture sterilization cycles.
• “Moving front” style has accept/reject readout for instant results withoutinterpretation, convenient small size for all packs, and optional extendersavailable for easy retrieval from inner packs.
• Immediately identify problems in specific packs.
• Safe, non-toxic chemicals; no worry of contamination or transfer to sterile items.
3M™ Comply™ (SteriGage™) EO Chemical Integrators
Cat. # Description Packaging Shipping
1244A EO Chemical Integrator; moving front; for gas 500 each/bag 2 bags/casemixture sterilizers; 2 in. x 3/4 in. (5,1 cm x 1,9 cm)
1244B EO Chemical Integrator; moving front; for gas 100 each/bag 10 bags/casemixture sterilizers; 2 in. x 3/4 in. (5,1 cm x 1,9 cm)
1244E EO Chemical Integrator; moving front with extender; 1000 each/bag 1 bag/casefor gas mixture sterilizers; 9 in. x 3/8 in. (22,9 cm x 1,0 cm)
1240E Extender only; 2500 each/bag 2 bags/case7-1/2 in. x 3/8 in. (19,1 cm x 1,0 cm)
Low Temperature Chemical Indicators
18
16
17
Steam Chemical Indicator Strips
14
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
15
Chemical Indicator Roll
Chemical indicators for steam in a roll. The chemical indicator lines will turndark brown when exposed to steam.
3M™ Comply™ Indicator Roll*
Cat. # Description Packaging Shipping
1201** Steam (60 yards) 10 rolls/box 1 box/case
*Contains Dry Natural Rubber**Can be used with 3M tape dispenser 1206 (see page 27 )
For use in all steam sterilizers. Long stripe of chemicalindicator ink printed on perforated-style strip. Allowsfull- or half-length use for different pack sizes. Utilizesdistinct color change to indicate process results.Indicator changes color from white to dark brown/black(dark or darker than the color block located in center ofstrip) when exposed to steam sterilization conditions.
3M™ Comply™ Steam Chemical Indicator Strip
Cat. # Description Packaging Shipping
1250 Steam Chemical Indicator Strip 240 each/box 8 boxes/case5/8 in. x 8 in. (1,5 cm x 20 cm)
For use in all steam sterilizers. Chemical indicatorprinted as block on one end of short or long strip.Indicator changes color to dark brown/black (blockturns as dark or darker than a color standard) whenexposed to steam sterilization conditions.
3M™ Comply™ Steam Chemical Indicator Strips
Cat. # Description Packaging Shipping
00107 Long Form, 250 each/box 20 boxes/case5/8 in. x 8-1/2 in. (1,5 cm x 22 cm)
00107A Long Form—Economy Pack 1000 each/box 4 boxes/case5/8 in. x 8-1/2 in. (1,5 cm x 22 cm)
00109 Short Form, 250 each/box 20 boxes/case5/8 in. x 4-1/4 in. (1,5 cm x 11 cm)
00109A Short Form—Economy Pack 1000 each/box 4 boxes/case5/8 in. x 4-1/4 in. 1,5 cm x 11 cm)
39390 catalog 3.qxd 4/12/02 4:15 PM Page 16
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Pack Con t ro l
19
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZY
MAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RSP ack Con t ro l
18
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZY
MAT
IC IN
DICA
TORS
BI
OLOG
ICAL
INDI
CATO
RS
Dry Heat Chemical Indicators
Sterilization monitor for dry heat sterilizers. Indicator changes color from tan toblack within 5 minutes at 170˚C (340˚F) during exposure to dry heat processing.
3M™ Comply™ Dry Heat Chemical Indicator Strip
Cat. # Description Packaging Shipping
00311 Dry Heat Chemical Indicator Strip 250 each/box 10 boxes/case5/8 in. x 4-1/4 in. (1,5 cm x 11 cm)
21
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Low Temperature Chemical Indicators (continued)
For use in 100% EO and EO/HCFC gas mixtures. Long stripe of chemical indicator ink printed onperforated-style strip. Allows full- or half-length use for different pack sizes. Indicator changes color fromburgundy red to green when exposed to ethylene oxidesterilization conditions.
3M™ Comply™ EO Chemical Indicator Strip
Cat. # Description Packaging Shipping
1251 EO Chemical Indicator Strip; 240 each/box 4 boxes/case5/8 in. x 8 in. (1,5 cm x 20 cm)
For use in 100% EO and EO/HCFC gas mixtures. Chemical indicatorink printed as a block on one end of short or long strips. Available inplastic-laminated and non-laminated, economy pack styles. Indicatorchanges color from yellow to blue when exposed to ethylene oxidesterilization conditions.
3M™ Comply™ EO Chemical Indicator Strips
Cat. # Description Packaging Shipping
00152 Short Form—Economy Pack 800 each/box 4 boxes/caseNon-laminated strips5/8 in. x 4-1/4 in. (1,5 cm x 11 cm)
00155 Short Form—Economy Pack 200 each/box 20 boxes/casePlastic-laminated strips5/8 in. x 4-1/4 in. (1,5 cm x 11 cm)
Chemical Indicator Roll
Chemical indicators for EO gas in a roll. The chemical indicator lines will turnred when exposed to EO gas.
3M™ Comply™ Indicator Roll*
Cat. # Description Packaging Shipping
1202** Ethylene Oxide (60 yards) 10 rolls/box 1 box/case
*Contains Dry Natural Rubber**Can be used with 3M tape dispenser 1206 (see page 27 )
20
19
39390 catalog 3.qxd 4/12/02 4:15 PM Page 18
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Pack Con t ro l
19
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZY
MAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RSP ack Con t ro l
18
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZY
MAT
IC IN
DICA
TORS
BI
OLOG
ICAL
INDI
CATO
RS
Dry Heat Chemical Indicators
Sterilization monitor for dry heat sterilizers. Indicator changes color from tan toblack within 5 minutes at 170˚C (340˚F) during exposure to dry heat processing.
3M™ Comply™ Dry Heat Chemical Indicator Strip
Cat. # Description Packaging Shipping
00311 Dry Heat Chemical Indicator Strip 250 each/box 10 boxes/case5/8 in. x 4-1/4 in. (1,5 cm x 11 cm)
21
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Low Temperature Chemical Indicators (continued)
For use in 100% EO and EO/HCFC gas mixtures. Long stripe of chemical indicator ink printed onperforated-style strip. Allows full- or half-length use for different pack sizes. Indicator changes color fromburgundy red to green when exposed to ethylene oxidesterilization conditions.
3M™ Comply™ EO Chemical Indicator Strip
Cat. # Description Packaging Shipping
1251 EO Chemical Indicator Strip; 240 each/box 4 boxes/case5/8 in. x 8 in. (1,5 cm x 20 cm)
For use in 100% EO and EO/HCFC gas mixtures. Chemical indicatorink printed as a block on one end of short or long strips. Available inplastic-laminated and non-laminated, economy pack styles. Indicatorchanges color from yellow to blue when exposed to ethylene oxidesterilization conditions.
3M™ Comply™ EO Chemical Indicator Strips
Cat. # Description Packaging Shipping
00152 Short Form—Economy Pack 800 each/box 4 boxes/caseNon-laminated strips5/8 in. x 4-1/4 in. (1,5 cm x 11 cm)
00155 Short Form—Economy Pack 200 each/box 20 boxes/casePlastic-laminated strips5/8 in. x 4-1/4 in. (1,5 cm x 11 cm)
Chemical Indicator Roll
Chemical indicators for EO gas in a roll. The chemical indicator lines will turnred when exposed to EO gas.
3M™ Comply™ Indicator Roll*
Cat. # Description Packaging Shipping
1202** Ethylene Oxide (60 yards) 10 rolls/box 1 box/case
*Contains Dry Natural Rubber**Can be used with 3M tape dispenser 1206 (see page 27 )
20
19
39390 catalog 3.qxd 4/12/02 4:15 PM Page 18
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Exposu re Con t ro l
21
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZY
MAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RSE qu ipmen t Con t ro l
20
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZY
MAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
Protects sharp-pointed surgical instruments from damage and reduces possibilityof pouch puncture during sterilization and handling. Indicators on the protectorsverify steam or EO gas processing.
3M™ Comply™ Instrument Protectors
Cat. # Description Packaging Shipping
13911 2 in. x 5 in. (5,1 cm x 12,8 cm) 100/pack 10 packs/case
13913 3-1/2 in. x 6-5/8 in. (9,9 cm x 16,8 cm) 100/pack 10 packs/case
13915 5-1/2 in. x 9-1/2 in. (14 cm x 24 cm) 100/pack 10 packs/case
Instrument Protectors
Sterilization Indicator Labels
Peel-off, pressure-sensitive labels for hard-surfaced items such as unwrappedglass or metal.
3M™ Comply™ Chemical Indicator Labels
Cat. # Description Packaging Shipping
00162 Steam/EO Gas— 1000 labels/roll 12 rolls/caseCombination label for steam or EO gas sterilizers. Steam 1 roll/boxindicator bar changes color from blue to black during steam sterilization. EO gas indicator changes color fromyellow to rust/red during EO gas sterilization.
00160 Steam—For steam sterilizers. Color changes from purple 1000 labels/roll 12 rolls/caseto green during steam sterilization. 1 roll/box
00170 Dry Heat—For use in dry heat sterilizers 170˚C 1000 labels/roll 12 rolls/case(340˚F) or above. The indicator ink on the label 1 roll/boxturns from tan to black within 5 minutes at 170˚C(340˚F) to verify exposure during dry heat sterilization.
23
24
25
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Each monitor consists of a plastic strip with a black-framed chemical reactionpad. Pad changes from white to yellow when dipped in glutaraldehyde solutionswith adequate concentration.
3M™ Comply™ Glutaraldehyde Monitors, 1.5%, 1.8%, 2.1%
Designed to test glutaraldehyde solutions with stated manufacturer’s MinimumEffectiveness Concentration (MEC) values. Indicates safe solutions when above1.5%, 1.8% or 2.1% MECs.
Cat. # Description Packaging Shipping
3983MM 1.5% MEC* 60 monitors/bottle 2 bottles/case
3987 1.8% MEC* 60 monitors/bottle 2 bottles/case
3989 2.1% MEC* 60 monitors/bottle 2 bottles/case
*Test strips are brand specific. Please contact 3M for details.
Each monitor contains a black-framed pad which turns yellow when a glutaraldehyde solution is above 1% concentration.
3M™ Comply™ Glutaraldehyde Monitors, 2% to 3.5%
Designed for glutaraldehyde solutions with starting concentrations of 2% to3.5%, but not labeled for specific MECs. Indicates safe solutions when above1% effective concentrations.
Cat. # Description Packaging Shipping
3552 - 60 monitors/bottle 12 bottles/case
3553 - 60 monitors/bottle 2 bottles/case
Glutaraldehyde Monitors
22
39390 catalog 3.qxd 4/12/02 4:16 PM Page 20
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Exposu re Con t ro l
21
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZY
MAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RSE qu ipmen t Con t ro l
20
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZY
MAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
Protects sharp-pointed surgical instruments from damage and reduces possibilityof pouch puncture during sterilization and handling. Indicators on the protectorsverify steam or EO gas processing.
3M™ Comply™ Instrument Protectors
Cat. # Description Packaging Shipping
13911 2 in. x 5 in. (5,1 cm x 12,8 cm) 100/pack 10 packs/case
13913 3-1/2 in. x 6-5/8 in. (9,9 cm x 16,8 cm) 100/pack 10 packs/case
13915 5-1/2 in. x 9-1/2 in. (14 cm x 24 cm) 100/pack 10 packs/case
Instrument Protectors
Sterilization Indicator Labels
Peel-off, pressure-sensitive labels for hard-surfaced items such as unwrappedglass or metal.
3M™ Comply™ Chemical Indicator Labels
Cat. # Description Packaging Shipping
00162 Steam/EO Gas— 1000 labels/roll 12 rolls/caseCombination label for steam or EO gas sterilizers. Steam 1 roll/boxindicator bar changes color from blue to black during steam sterilization. EO gas indicator changes color fromyellow to rust/red during EO gas sterilization.
00160 Steam—For steam sterilizers. Color changes from purple 1000 labels/roll 12 rolls/caseto green during steam sterilization. 1 roll/box
00170 Dry Heat—For use in dry heat sterilizers 170˚C 1000 labels/roll 12 rolls/case(340˚F) or above. The indicator ink on the label 1 roll/boxturns from tan to black within 5 minutes at 170˚C(340˚F) to verify exposure during dry heat sterilization.
23
24
25
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Each monitor consists of a plastic strip with a black-framed chemical reactionpad. Pad changes from white to yellow when dipped in glutaraldehyde solutionswith adequate concentration.
3M™ Comply™ Glutaraldehyde Monitors, 1.5%, 1.8%, 2.1%
Designed to test glutaraldehyde solutions with stated manufacturer’s MinimumEffectiveness Concentration (MEC) values. Indicates safe solutions when above1.5%, 1.8% or 2.1% MECs.
Cat. # Description Packaging Shipping
3983MM 1.5% MEC* 60 monitors/bottle 2 bottles/case
3987 1.8% MEC* 60 monitors/bottle 2 bottles/case
3989 2.1% MEC* 60 monitors/bottle 2 bottles/case
*Test strips are brand specific. Please contact 3M for details.
Each monitor contains a black-framed pad which turns yellow when a glutaraldehyde solution is above 1% concentration.
3M™ Comply™ Glutaraldehyde Monitors, 2% to 3.5%
Designed for glutaraldehyde solutions with starting concentrations of 2% to3.5%, but not labeled for specific MECs. Indicates safe solutions when above1% effective concentrations.
Cat. # Description Packaging Shipping
3552 - 60 monitors/bottle 12 bottles/case
3553 - 60 monitors/bottle 2 bottles/case
Glutaraldehyde Monitors
22
39390 catalog 3.qxd 4/12/02 4:16 PM Page 20
Equ ipmen t Con t ro l
23
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CH
EMIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Bowie-Dick Plus Test Pack features the Early Warning Test Sheet that identifies potential air leaks or vacuum pump failures before they appear on the Bowie-Dick test sheet.
3M™ Comply™ Bowie-Dick Plus Test Pack with Early Warning Test Sheet
Cat. # Description Packaging Shipping
00135 Comply Bowie-Dick Plus Test Pack with 20 packs/box 4 boxes/caseEarly Warning Test Sheet
Bowie-Dick Plus Test Pack with Early Warning Test Sheet
Designed for vacuum-assisted sterilizers to test the efficacy of the vacuumsystem, to remove air from the sterilizer chamber and to detect leaks in the system that would allow air into the chamber.
• Bowie-Dick test packs make testing steam penetration and air removal,as well as detecting air leaks, more convenient and cost effective
• Designed to give equivalent results to those obtainable by the Bowie and Dick protocol
• Preassembled packs reduce both labor and material costs
• Indicator pattern is easy to read and interpret
3M™ Comply™ Bowie-Dick Type Test Pack
Cat. # Description Packaging Shipping
1233 Comply Disposable Test Pack 6 packs/bag 5 bags/case
3M™ Comply™ Bowie-Dick Test Sheets
Cat. # Description Packaging Shipping
00130 Comply Internal Steam Indicator Sheets 50 sheets/box 5 boxes/case
Bowie-Dick Type Test Packs and Sheets
27
26
Bowie-Dick Test Packs
39390 catalog 3.qxd 4/12/02 4:16 PM Page 22
Equ ipmen t Con t ro l
23
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CH
EMIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Bowie-Dick Plus Test Pack features the Early Warning Test Sheet that identifies potential air leaks or vacuum pump failures before they appear on the Bowie-Dick test sheet.
3M™ Comply™ Bowie-Dick Plus Test Pack with Early Warning Test Sheet
Cat. # Description Packaging Shipping
00135 Comply Bowie-Dick Plus Test Pack with 20 packs/box 4 boxes/caseEarly Warning Test Sheet
Bowie-Dick Plus Test Pack with Early Warning Test Sheet
Designed for vacuum-assisted sterilizers to test the efficacy of the vacuumsystem, to remove air from the sterilizer chamber and to detect leaks in the system that would allow air into the chamber.
• Bowie-Dick test packs make testing steam penetration and air removal,as well as detecting air leaks, more convenient and cost effective
• Designed to give equivalent results to those obtainable by the Bowie and Dick protocol
• Preassembled packs reduce both labor and material costs
• Indicator pattern is easy to read and interpret
3M™ Comply™ Bowie-Dick Type Test Pack
Cat. # Description Packaging Shipping
1233 Comply Disposable Test Pack 6 packs/bag 5 bags/case
3M™ Comply™ Bowie-Dick Test Sheets
Cat. # Description Packaging Shipping
00130 Comply Internal Steam Indicator Sheets 50 sheets/box 5 boxes/case
Bowie-Dick Type Test Packs and Sheets
27
26
Bowie-Dick Test Packs
39390 catalog 3.qxd 4/12/02 4:16 PM Page 22
Exposu re Con t ro l P roduc t s
25
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RSST
ERIL
IZAT
ION
HARD
WAR
E
C
LEAN
ING
AND
DECO
NTAM
INAT
ION
REC
ORD
KEEP
ING
INDI
CATO
R TA
PES
BOW
IE-D
ICK
TEST
PAC
KS
C
HEM
ICAL
INDI
CATO
RS
E
NZYM
ATIC
INDI
CATO
RS
B
IOLO
GICA
LIN
DICA
TORS
Indicator Tape for Steam Sterilization
28
A reliable steam indicator tape that provides immediate identification ofprocessed items and also serves as a closure tape to seal sterilization packs. The chemical indicator lines will turn dark when exposed to a steam sterilization process.
• Reliable chemical indicator responds when exposed to a steam sterilization process
• Adheres to woven, treated woven, non-woven, paper and paper/plastic wraps
• Adhesive seals packs securely, but is easy to remove
• Backing stretches to minimize tape pop-off during pack sterilization
• Can be written on or labeled with preprinted labels such as 3M™ Comply™
Sterilization Record Labels (page 31)
3M™ Comply™ Indicator Tape for Steam Sterilization*
Cat. # Description Packaging Shipping
1222-0N 1/2 in. x 60 yd. (1,25 cm x 55 m) - 36 rolls/caseWhite
1222-1N 1 in. x 60 yd. (2,5 cm x 55 m) - 18 rolls/caseWhite
1222-2N 2 in. x 60 yd. (5 cm x 55 m) - 10 rolls/caseWhite
1222-6N 3/4 in. x 60 yd. (1,9 cm x 55 m) - 24 rolls/caseWhite
*Contains Dry Natural Rubber.
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Indicator Tapes
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
SBO
WIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
39390 catalog 3.qxd 4/12/02 4:17 PM Page 24
Exposu re Con t ro l P roduc t s
25
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RSST
ERIL
IZAT
ION
HARD
WAR
E
C
LEAN
ING
AND
DECO
NTAM
INAT
ION
REC
ORD
KEEP
ING
INDI
CATO
R TA
PES
BOW
IE-D
ICK
TEST
PAC
KS
C
HEM
ICAL
INDI
CATO
RS
E
NZYM
ATIC
INDI
CATO
RS
B
IOLO
GICA
LIN
DICA
TORS
Indicator Tape for Steam Sterilization
28
A reliable steam indicator tape that provides immediate identification ofprocessed items and also serves as a closure tape to seal sterilization packs. The chemical indicator lines will turn dark when exposed to a steam sterilization process.
• Reliable chemical indicator responds when exposed to a steam sterilization process
• Adheres to woven, treated woven, non-woven, paper and paper/plastic wraps
• Adhesive seals packs securely, but is easy to remove
• Backing stretches to minimize tape pop-off during pack sterilization
• Can be written on or labeled with preprinted labels such as 3M™ Comply™
Sterilization Record Labels (page 31)
3M™ Comply™ Indicator Tape for Steam Sterilization*
Cat. # Description Packaging Shipping
1222-0N 1/2 in. x 60 yd. (1,25 cm x 55 m) - 36 rolls/caseWhite
1222-1N 1 in. x 60 yd. (2,5 cm x 55 m) - 18 rolls/caseWhite
1222-2N 2 in. x 60 yd. (5 cm x 55 m) - 10 rolls/caseWhite
1222-6N 3/4 in. x 60 yd. (1,9 cm x 55 m) - 24 rolls/caseWhite
*Contains Dry Natural Rubber.
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Indicator Tapes
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
SBO
WIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
39390 catalog 3.qxd 4/12/02 4:17 PM Page 24
Exposu re Con t ro l P roduc t s
27
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
BOW
IE-D
ICK
TEST
PAC
KS
C
HEM
ICAL
INDI
CATO
RS
E
NZYM
ATIC
INDI
CATO
RS
B
IOLO
GICA
LIN
DICA
TORSE xposu re Con t ro l P roduc t s
26
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
SBO
WIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
Indicator Tape Dispensers
1206 Tape Dispenser
The 1206 tape dispenser has a weighted base and is capable of handling two 1-inch rolls or one 2-inch roll of indicator tape, or one 2-inch Comply indicator roll.
Cat. # Description Packaging Shipping
1206 Weighted base, holds 2 rolls - 1 each/case
C22 Heavy Duty Tape Dispenser
The C22 heavy duty tape dispenser is made of rugged, high-impact, durable plastic and iscapable of handling two rolls of 1-inch wide indicator tape.
Cat. # Description Packaging Shipping
C22 Heavy duty, holds 2 rolls - 2 each/case
M51/M51-T Tape Dispenser
The M51 tape dispenser holds one indicator tape roll up to 1 inch in width. The M51-T isthe same as the M51 dispenser with the addition of the tabber attachment, whichautomatically folds a 1/4-inch length of tape for easy handling and removal.
Cat. # Description Packaging Shipping
M51 Without tabber - 6 each/case
M51-T With tabber - 6 each/case
M96 Definite-Length Tape Dispenser
The M96 definite-length tape dispenser adjusts to allow consistent dispensing of indicatortape strips, up to 5 inches in length. Holds one indicator tape roll up to 1 inch in width.
Cat. # Description Packaging Shipping
M96 Definite length (with wheel accessory) - 6 each/case
M920 Definite-Length Tape Dispenser
The M920 definite-length tape dispenser adjusts to allow consistent dispensing of indicatortape strips, up to 4 inches in length. Holds one indicator tape roll up to 1 inch in width.
Cat. # Description Packaging Shipping
M920 Definite length - 6 each/case
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
31
A reliable steam indicator tape specifically designed for disposable wraps thatprovides immediate identification of processed items and also serves as a closureto seal sterilization packs. The chemical indicator lines will turn dark whenexposed to a steam sterilization process.
• “Blue tape” is the industry’s first indicator tape for disposable wraps
• Aggressive adhesive secures packs wrapped with disposable materials
• Uses the same reliable chemical indicator as 3M™ Comply™ 1222Indicator Tape
• Backing stretches to minimize tape pop-off during pack sterilization
• Can be written on or labeled with preprinted labels such as 3M™ Comply™
Sterilization Record Labels (page 31)
3M™ Comply™ Steam Indicator Tape for Disposable Wraps*
Cat. # Description Packaging Shipping
1255-1N 1 in. x 60 yd. (2,5 cm x 55 m) - 18 rolls/caseTape for Steam
1255-6N 3/4 in. x 60 yd. (1,9 cm x 55 m) - 24 rolls/caseTape for Steam
*Contains Dry Natural Rubber.
Steam Indicator Tape for Disposable Wraps
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
A reliable ethylene oxide gas indicator tape that instantly identifies items that have been exposed to EO gas and also serves as a closure tape to sealsterilization packs. The chemical indicator lines will turn red when exposed to an EO sterilization process.
• Adhesive seals packs securely, but is easily removed, leaving no adhesive residue
• Color change verifies exposure to ethylene oxide gas
• Backing stretches to minimize tape pop-off during pack sterilization
• Can be written on or labeled with preprinted labels such as 3M™ Comply™
Sterilization Record Labels (page 31)
3M™ Comply™ Indicator Tape for Ethylene Oxide Sterilization*
Cat. # Description Packaging Shipping
1224-0 1/2 in. x 60 yd. - 36 rolls/case(1,25 cm x 55 m)
1224-1 1 in. x 60 yd. - 18 rolls/case(2,5 cm x 55 m)
1224-6 3/4 in. x 60 yd. - 24 rolls/case(1,9 cm x 55 m)
*Contains Dry Natural Rubber.
Indicator Tape for Ethylene Oxide (EO) Sterilization
30
29
39390 catalog 3.qxd 4/12/02 4:17 PM Page 26
Exposu re Con t ro l P roduc t s
27
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
BOW
IE-D
ICK
TEST
PAC
KS
C
HEM
ICAL
INDI
CATO
RS
E
NZYM
ATIC
INDI
CATO
RS
B
IOLO
GICA
LIN
DICA
TORSE xposu re Con t ro l P roduc t s
26
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
SBO
WIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
Indicator Tape Dispensers
1206 Tape Dispenser
The 1206 tape dispenser has a weighted base and is capable of handling two 1-inch rolls or one 2-inch roll of indicator tape, or one 2-inch Comply indicator roll.
Cat. # Description Packaging Shipping
1206 Weighted base, holds 2 rolls - 1 each/case
C22 Heavy Duty Tape Dispenser
The C22 heavy duty tape dispenser is made of rugged, high-impact, durable plastic and iscapable of handling two rolls of 1-inch wide indicator tape.
Cat. # Description Packaging Shipping
C22 Heavy duty, holds 2 rolls - 2 each/case
M51/M51-T Tape Dispenser
The M51 tape dispenser holds one indicator tape roll up to 1 inch in width. The M51-T isthe same as the M51 dispenser with the addition of the tabber attachment, whichautomatically folds a 1/4-inch length of tape for easy handling and removal.
Cat. # Description Packaging Shipping
M51 Without tabber - 6 each/case
M51-T With tabber - 6 each/case
M96 Definite-Length Tape Dispenser
The M96 definite-length tape dispenser adjusts to allow consistent dispensing of indicatortape strips, up to 5 inches in length. Holds one indicator tape roll up to 1 inch in width.
Cat. # Description Packaging Shipping
M96 Definite length (with wheel accessory) - 6 each/case
M920 Definite-Length Tape Dispenser
The M920 definite-length tape dispenser adjusts to allow consistent dispensing of indicatortape strips, up to 4 inches in length. Holds one indicator tape roll up to 1 inch in width.
Cat. # Description Packaging Shipping
M920 Definite length - 6 each/case
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
31
A reliable steam indicator tape specifically designed for disposable wraps thatprovides immediate identification of processed items and also serves as a closureto seal sterilization packs. The chemical indicator lines will turn dark whenexposed to a steam sterilization process.
• “Blue tape” is the industry’s first indicator tape for disposable wraps
• Aggressive adhesive secures packs wrapped with disposable materials
• Uses the same reliable chemical indicator as 3M™ Comply™ 1222Indicator Tape
• Backing stretches to minimize tape pop-off during pack sterilization
• Can be written on or labeled with preprinted labels such as 3M™ Comply™
Sterilization Record Labels (page 31)
3M™ Comply™ Steam Indicator Tape for Disposable Wraps*
Cat. # Description Packaging Shipping
1255-1N 1 in. x 60 yd. (2,5 cm x 55 m) - 18 rolls/caseTape for Steam
1255-6N 3/4 in. x 60 yd. (1,9 cm x 55 m) - 24 rolls/caseTape for Steam
*Contains Dry Natural Rubber.
Steam Indicator Tape for Disposable Wraps
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
A reliable ethylene oxide gas indicator tape that instantly identifies items that have been exposed to EO gas and also serves as a closure tape to sealsterilization packs. The chemical indicator lines will turn red when exposed to an EO sterilization process.
• Adhesive seals packs securely, but is easily removed, leaving no adhesive residue
• Color change verifies exposure to ethylene oxide gas
• Backing stretches to minimize tape pop-off during pack sterilization
• Can be written on or labeled with preprinted labels such as 3M™ Comply™
Sterilization Record Labels (page 31)
3M™ Comply™ Indicator Tape for Ethylene Oxide Sterilization*
Cat. # Description Packaging Shipping
1224-0 1/2 in. x 60 yd. - 36 rolls/case(1,25 cm x 55 m)
1224-1 1 in. x 60 yd. - 18 rolls/case(2,5 cm x 55 m)
1224-6 3/4 in. x 60 yd. - 24 rolls/case(1,9 cm x 55 m)
*Contains Dry Natural Rubber.
Indicator Tape for Ethylene Oxide (EO) Sterilization
30
29
39390 catalog 3.qxd 4/12/02 4:17 PM Page 26
Record Keep ing
29
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
GIN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
An efficient and secure system for all sterilization process monitoringdocumentation. Easily and accurately record, review, archive, and retrievesterilization process monitoring data. Use to consolidate all sterilization process data into an easily accessible database. Regular compliance promptshelp maintain compliance with JCAHO and other recommended standards.
3M™ Record Keeping Software
Cat. # Description Packaging Shipping
1213A Record Keeping Software - 1 each/case
Please contact your 3M Sales Representative for ordering information about this product.
Record Keeping Software
Log Books, Envelopes and Record Charts
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Complete record keeping systems that maintain your sterilization processinformation and reduce record keeping time to just minutes each day. The preprinted log books put all the information you need to help you meet requirements at your fingertips.
3M™ Log Book and Envelopes
Cat. # Description Packaging Shipping
1254B Sterilization Log Book for envelopes (empty) - 1 each/case
1254E-F 100 flash envelopes for 1254B Log Book 100 each/pack 5 packs/case
1254E-S 100 steam envelopes for 1254B Log Book 100 each/pack 5 packs/case
1254E-LT 100 low temperature envelopes for 1254B Log Book 100 each/pack 5 packs/case
3M™ Log Books and Record Sheets
Cat. # Description Packaging Shipping
1266 Steam Log Book (small sheets) - 1 each/case
1266S 50 replacement sheets for 1266 Log Book 50 each/pack 1 pack/case
1268 Low Temperature Log Book (small sheets) - 1 each/case
1268S 50 replacement sheets for 1268 Log Book 50 each/pack 1 pack/case
1283 Glutaraldehyde Log Book (small sheets) - 1 each/case
1283S 50 replacement sheets for 1283 Log Book 50 each/pack 1 pack/case
Record Keeping
32
34
33
39390 catalog 3.qxd 4/12/02 4:18 PM Page 28
Record Keep ing
29
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
GIN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
An efficient and secure system for all sterilization process monitoringdocumentation. Easily and accurately record, review, archive, and retrievesterilization process monitoring data. Use to consolidate all sterilization process data into an easily accessible database. Regular compliance promptshelp maintain compliance with JCAHO and other recommended standards.
3M™ Record Keeping Software
Cat. # Description Packaging Shipping
1213A Record Keeping Software - 1 each/case
Please contact your 3M Sales Representative for ordering information about this product.
Record Keeping Software
Log Books, Envelopes and Record Charts
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Complete record keeping systems that maintain your sterilization processinformation and reduce record keeping time to just minutes each day. The preprinted log books put all the information you need to help you meet requirements at your fingertips.
3M™ Log Book and Envelopes
Cat. # Description Packaging Shipping
1254B Sterilization Log Book for envelopes (empty) - 1 each/case
1254E-F 100 flash envelopes for 1254B Log Book 100 each/pack 5 packs/case
1254E-S 100 steam envelopes for 1254B Log Book 100 each/pack 5 packs/case
1254E-LT 100 low temperature envelopes for 1254B Log Book 100 each/pack 5 packs/case
3M™ Log Books and Record Sheets
Cat. # Description Packaging Shipping
1266 Steam Log Book (small sheets) - 1 each/case
1266S 50 replacement sheets for 1266 Log Book 50 each/pack 1 pack/case
1268 Low Temperature Log Book (small sheets) - 1 each/case
1268S 50 replacement sheets for 1268 Log Book 50 each/pack 1 pack/case
1283 Glutaraldehyde Log Book (small sheets) - 1 each/case
1283S 50 replacement sheets for 1283 Log Book 50 each/pack 1 pack/case
Record Keeping
32
34
33
39390 catalog 3.qxd 4/12/02 4:18 PM Page 28
Record Keep ing
31
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
RE
CORD
KEEP
ING
INDI
CATO
R TA
PES
BOW
IE-D
ICK
TEST
PAC
KS
C
HEM
ICAL
INDI
CATO
RS
E
NZYM
ATIC
INDI
CATO
RS
B
IOLO
GICA
LIN
DICA
TORSR eco rd Keep ing
30
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
GIN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
3M™ Comply™ Label Gun
Cat. # Description Packaging Shipping
1256B Printing applicator—prints and applies labels 1 each/box 1 box/casedirectly where needed
Event Related Sterilization Record Labels—“Sterilized”
Cat. # Description Packaging Shipping
1269B Blue labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1269BL Black labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1269G Green labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1269R Red labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
Sterilization Record Labels—“Expires”
Cat. # Description Packaging Shipping
1257B Blue labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257BL Black labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257BR Brown labels;. 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in (2,85 cm x 1,58 cm) 12 rolls/box
1257G Green labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257GD Gold labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257GY Grey labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257OR Orange labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257P Purple labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257PK Pink labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257R Red labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257Y Yellow labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
Labels Contain Dry Natural Rubber
Sterilization Record Labels—Blank
Cat. # Description Packaging Shipping
1257W White labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
Labels Contain Dry Natural Rubber
Label Gun System
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
35
Load Record Cards
For steam and EO gas sterilizers. Provides a permanent record of sterilizer useand work flow.
3M™ Comply™ Load Record Cards
Cat. # Description Packaging Shipping
1252 Steam load record card 240 each/box 4 boxes/case3 in. x 5 in. (7,6 cm x 12,8 cm)
1253 EO load record card 240 each/box 2 boxes/case3 in. x 5 in. (7,6 cm x 12,8 cm)
67200 Steam and EO load record card 250 each/box 4 boxes/case3 in. x 5 in. (7,6 cm x 12,8 cm)
67201 Steam and EO load record card 250 each/box 4 boxes/case4 in. x 5-1/2 in. (10,2 cm x 14 cm)
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Sterilization Integrator Load Record Card
A single-use device that indicates whether materials within a pack or load havebeen exposed to conditions necessary for sterilization. The steam sterilizationrecord cards can be used in vacuum, gravity and flash sterilizers.
3M™ Comply™ Load Record Card
Cat. # Description Packaging Shipping
4171MM Integrator with Load Record Card—Steam 100 each/box 1 box/case
39390 catalog 3.qxd 4/12/02 4:18 PM Page 30
Record Keep ing
31
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
RE
CORD
KEEP
ING
INDI
CATO
R TA
PES
BOW
IE-D
ICK
TEST
PAC
KS
C
HEM
ICAL
INDI
CATO
RS
E
NZYM
ATIC
INDI
CATO
RS
B
IOLO
GICA
LIN
DICA
TORSR eco rd Keep ing
30
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
N
R
ECOR
DKE
EPIN
GIN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
3M™ Comply™ Label Gun
Cat. # Description Packaging Shipping
1256B Printing applicator—prints and applies labels 1 each/box 1 box/casedirectly where needed
Event Related Sterilization Record Labels—“Sterilized”
Cat. # Description Packaging Shipping
1269B Blue labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1269BL Black labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1269G Green labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1269R Red labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
Sterilization Record Labels—“Expires”
Cat. # Description Packaging Shipping
1257B Blue labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257BL Black labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257BR Brown labels;. 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in (2,85 cm x 1,58 cm) 12 rolls/box
1257G Green labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257GD Gold labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257GY Grey labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257OR Orange labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257P Purple labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257PK Pink labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257R Red labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
1257Y Yellow labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
Labels Contain Dry Natural Rubber
Sterilization Record Labels—Blank
Cat. # Description Packaging Shipping
1257W White labels; 1125 labels/roll 1 box/case1-1/8 in. x 5/8 in. (2,85 cm x 1,58 cm) 12 rolls/box
Labels Contain Dry Natural Rubber
Label Gun System
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
35
Load Record Cards
For steam and EO gas sterilizers. Provides a permanent record of sterilizer useand work flow.
3M™ Comply™ Load Record Cards
Cat. # Description Packaging Shipping
1252 Steam load record card 240 each/box 4 boxes/case3 in. x 5 in. (7,6 cm x 12,8 cm)
1253 EO load record card 240 each/box 2 boxes/case3 in. x 5 in. (7,6 cm x 12,8 cm)
67200 Steam and EO load record card 250 each/box 4 boxes/case3 in. x 5 in. (7,6 cm x 12,8 cm)
67201 Steam and EO load record card 250 each/box 4 boxes/case4 in. x 5-1/2 in. (10,2 cm x 14 cm)
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Sterilization Integrator Load Record Card
A single-use device that indicates whether materials within a pack or load havebeen exposed to conditions necessary for sterilization. The steam sterilizationrecord cards can be used in vacuum, gravity and flash sterilizers.
3M™ Comply™ Load Record Card
Cat. # Description Packaging Shipping
4171MM Integrator with Load Record Card—Steam 100 each/box 1 box/case
39390 catalog 3.qxd 4/12/02 4:18 PM Page 30
Ste r i l i za t i on Assu rance
33
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
NRE
CORD
KEEP
ING
INDI
CATO
R TA
PES
BOW
IE-D
ICK
TEST
PAC
KS
C
HEM
ICAL
INDI
CATO
RS
E
NZYM
ATIC
INDI
CATO
RS
B
IOLO
GICA
LIN
DICA
TORS
An effective multi-enzyme detergent used for cleaning metallic and plasticmedical instruments, including flexible and rigid endoscopes, and dentalinstruments. Effectively digests human secretions after immersion for only 2–10 minutes. Made with biodegradable materials.
3M™ Rapid Multi-Enzyme Detergent
Cat. # Description Packaging Shipping
70500-B 5 liter bottle 3 each/case case
70500-D 1 liter bottle 12 each/case case
70500-H 100ml bottle 40 each/case case
Multi-Enzyme Detergent
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Cleaning and Decontamination
36
39390 catalog 3.qxd 4/12/02 4:19 PM Page 32
Ste r i l i za t i on Assu rance
33
STER
ILIZ
ATIO
N HA
RDW
ARE
CLE
ANIN
G AN
D DE
CONT
AMIN
ATIO
NRE
CORD
KEEP
ING
INDI
CATO
R TA
PES
BOW
IE-D
ICK
TEST
PAC
KS
C
HEM
ICAL
INDI
CATO
RS
E
NZYM
ATIC
INDI
CATO
RS
B
IOLO
GICA
LIN
DICA
TORS
An effective multi-enzyme detergent used for cleaning metallic and plasticmedical instruments, including flexible and rigid endoscopes, and dentalinstruments. Effectively digests human secretions after immersion for only 2–10 minutes. Made with biodegradable materials.
3M™ Rapid Multi-Enzyme Detergent
Cat. # Description Packaging Shipping
70500-B 5 liter bottle 3 each/case case
70500-D 1 liter bottle 12 each/case case
70500-H 100ml bottle 40 each/case case
Multi-Enzyme Detergent
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Cleaning and Decontamination
36
39390 catalog 3.qxd 4/12/02 4:19 PM Page 32
Ste r i l i za t i on Assu rance
35
STER
ILIZ
ATIO
N HA
RDW
ARE
CLEA
NING
AND
DEC
ONTA
MIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
These dual-cycle, 100% EO gas sterilizer/aerators have 4.0 cu. ft. (4XL) and 4.8 cu. ft. (5XL) chambers.
• 100% Ethylene Oxide—proven effective and trusted by health care providersworldwide for sterilization of heat and/or moisture-sensitive devices
• Video screen technology shows cycle status
• Single unit-dose EO cartridge is punctured inside the negative-pressurechamber only when proper chamber conditions are achieved
• Continuous temperature monitoring maintains temperature of the selectedcycle and automatically shuts off if the temperature exceeds setpoint
• Programmable access codes allow you to monitor and trace cycle operator
• Built-in aeration cycle
• Relative humidity detection and documentation (optional)
3M™ Steri-Vac™ 4XL and 5XL Sterilizer/Aerators
Cat. # Description Shipping
4XL Sterilizer/aerator 1 unit/caseChamber: 16-1/8" (H) x 18-1/8" (W) x 24" (D)
41 cm (H) x 46 cm (W) x 61 cm (D)
5XL Sterilizer/aerator 1 unit/caseChamber: 15" (H) x 17" (W) x 33-3/4"(D)
38 cm (H) x 43 cm (W) x 83 cm (D)
The model 8XL dual-cycle 100% EO gas sterilizer/ aerator has a 7.9 cu. ft.chamber. In addition to all of the benefits of the 4XL and 5XL, the 8XL provides:
• 100% Ethylene Oxide—proven effective and trusted by health care providersworldwide for sterilization of heat and/or moisture-sensitive devices
• Dependable computer controlled electronic design provides accuracy—automatically stops cycle and displays error code if error is detected
• Relative humidity feature continuously monitors, maintains and documentsthe proper humidity in the sterilization chamber during the precondition phase
3M™ Steri-Vac™ 8XL Sterilizer/Aerator
Cat. # Description Shipping
8XL Sterilizer/aerator 1 unit/caseExterior: 70" (H) x 37" (W) x 43" (D)
179 cm (H) x 94 cm (W) x 109 cm (D)Chamber: 18-1/8" (H) x 20" (W) x 38" (D)
46 cm (H) x 51 cm (W) x 97 cm (D)
Gas Sterilizers/Aerators
37
38
Sterilization Hardware
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
39390 catalog 3.qxd 4/12/02 4:19 PM Page 34
Ste r i l i za t i on Assu rance
35
STER
ILIZ
ATIO
N HA
RDW
ARE
CLEA
NING
AND
DEC
ONTA
MIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
These dual-cycle, 100% EO gas sterilizer/aerators have 4.0 cu. ft. (4XL) and 4.8 cu. ft. (5XL) chambers.
• 100% Ethylene Oxide—proven effective and trusted by health care providersworldwide for sterilization of heat and/or moisture-sensitive devices
• Video screen technology shows cycle status
• Single unit-dose EO cartridge is punctured inside the negative-pressurechamber only when proper chamber conditions are achieved
• Continuous temperature monitoring maintains temperature of the selectedcycle and automatically shuts off if the temperature exceeds setpoint
• Programmable access codes allow you to monitor and trace cycle operator
• Built-in aeration cycle
• Relative humidity detection and documentation (optional)
3M™ Steri-Vac™ 4XL and 5XL Sterilizer/Aerators
Cat. # Description Shipping
4XL Sterilizer/aerator 1 unit/caseChamber: 16-1/8" (H) x 18-1/8" (W) x 24" (D)
41 cm (H) x 46 cm (W) x 61 cm (D)
5XL Sterilizer/aerator 1 unit/caseChamber: 15" (H) x 17" (W) x 33-3/4"(D)
38 cm (H) x 43 cm (W) x 83 cm (D)
The model 8XL dual-cycle 100% EO gas sterilizer/ aerator has a 7.9 cu. ft.chamber. In addition to all of the benefits of the 4XL and 5XL, the 8XL provides:
• 100% Ethylene Oxide—proven effective and trusted by health care providersworldwide for sterilization of heat and/or moisture-sensitive devices
• Dependable computer controlled electronic design provides accuracy—automatically stops cycle and displays error code if error is detected
• Relative humidity feature continuously monitors, maintains and documentsthe proper humidity in the sterilization chamber during the precondition phase
3M™ Steri-Vac™ 8XL Sterilizer/Aerator
Cat. # Description Shipping
8XL Sterilizer/aerator 1 unit/caseExterior: 70" (H) x 37" (W) x 43" (D)
179 cm (H) x 94 cm (W) x 109 cm (D)Chamber: 18-1/8" (H) x 20" (W) x 38" (D)
46 cm (H) x 51 cm (W) x 97 cm (D)
Gas Sterilizers/Aerators
37
38
Sterilization Hardware
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
39390 catalog 3.qxd 4/12/02 4:19 PM Page 34
Ste r i l i za t i on Assu rance
37
STER
ILIZ
ATIO
N HA
RDW
ARE
CLEA
NING
AND
DEC
ONTA
MIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RSS t e r i l i za t i on Assu rance
36
STER
ILIZ
ATIO
N HA
RDW
ARE
CLEA
NING
AND
DEC
ONTA
MIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
42
Transfer Cart
A stainless steel transfer cart developed to assist operators to move, lift or lower materials and supplies around the Central Service/Sterile Processing Department.
• Table top extends up to 142,2 cm (56 in.) to accommodate load transfer
• Stainless steel table top provides durable surface
• Upper table pedal slowly raises the height of cart’s table top
• Lower table pedal allows for controllable lowering of table top
• Brake actuation pedal secures cart placement
3M™ Transfer Cart
Cat. # Description Shipping
6010 Transfer Cart 1 cart/caseTable size: 18-1/2" x 35" (47 cm x 89 cm); 19-3/4" x 35" (50 cm x 89 cm) for 8XL Kit Holding capacity: 68 kg
Aerator
39
The model XL aeration cabinet circulates warm, filtered air in its 5 cu. ft.chamber. Designed for compatibility with Steri-Vac sterilizers.
• Two selectable aeration temperatures, 37˚C (99˚F) or 55˚C (131˚F)
• Modular system for versatility
• Space efficient
• A door lock prevents unauthorized access
3M™ Steri-Vac™ XL Aerator
Cat. # Description Shipping
XL Aerator 1 unit/caseExterior: 24-3/8" (H) x 30-3/4" (W) x 36-5/8" (D)
62 cm (H) x 78 cm (W) x 93 cm (D)Chamber: 16-1/8" (H) x 18-1/8" (W) x 33" (D)
41 cm (H) x 46 cm (W) x 84 cm (D)
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Drying Cabinet
The model 45 dramatically reduces the time required to dry inhalation therapyand anesthesia equipment to between one-half and three hours.
• Capacity for drying 45 tubes from 6 mm (1/4 in.) to 44 mm (1-3/4 in.) indiameter at one time
• Removable wire basket for drying small parts in one-half of the cabinet, whiledrying tubing in the other half
• Capacity for holding four baskets— two deep on each side of the cabinet ortwo double baskets across the cabinet
• Dries tubes in a fraction of the time
3M™ Steri-Vac™ Drying Cabinet
Cat. # Description Shipping
45AA Drying Cabinet with wall mounting bracket 1 unit/case68-7/8" (H) x 22-3/8" (W) x 15-1/2" (D)175 cm (H) x 57 cm (W) x 42 cm (D)
41
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
The abator removes EO gas exhausted from 3M™ Steri-Vac™ sterilizers and aerators, converting it into CO2 and water vapor. At normal operatingtemperatures and concentrations, removal efficiency is 99.9+%.
• Works automatically with sterilization system
• Interfaces with up to two sterilizers
3M™ EtO-Abator System
Cat. # Description Shipping
50SCFM Abator 1 unit/case31" (H) x 32" (W) x 41" (D)80 cm (H) x 82 cm (W) x 105 cm (D)
3M™ EtO-Abator System
40
39390 catalog 3.qxd 4/12/02 4:19 PM Page 36
Ste r i l i za t i on Assu rance
37
STER
ILIZ
ATIO
N HA
RDW
ARE
CLEA
NING
AND
DEC
ONTA
MIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RSS t e r i l i za t i on Assu rance
36
STER
ILIZ
ATIO
N HA
RDW
ARE
CLEA
NING
AND
DEC
ONTA
MIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
42
Transfer Cart
A stainless steel transfer cart developed to assist operators to move, lift or lower materials and supplies around the Central Service/Sterile Processing Department.
• Table top extends up to 142,2 cm (56 in.) to accommodate load transfer
• Stainless steel table top provides durable surface
• Upper table pedal slowly raises the height of cart’s table top
• Lower table pedal allows for controllable lowering of table top
• Brake actuation pedal secures cart placement
3M™ Transfer Cart
Cat. # Description Shipping
6010 Transfer Cart 1 cart/caseTable size: 18-1/2" x 35" (47 cm x 89 cm); 19-3/4" x 35" (50 cm x 89 cm) for 8XL Kit Holding capacity: 68 kg
Aerator
39
The model XL aeration cabinet circulates warm, filtered air in its 5 cu. ft.chamber. Designed for compatibility with Steri-Vac sterilizers.
• Two selectable aeration temperatures, 37˚C (99˚F) or 55˚C (131˚F)
• Modular system for versatility
• Space efficient
• A door lock prevents unauthorized access
3M™ Steri-Vac™ XL Aerator
Cat. # Description Shipping
XL Aerator 1 unit/caseExterior: 24-3/8" (H) x 30-3/4" (W) x 36-5/8" (D)
62 cm (H) x 78 cm (W) x 93 cm (D)Chamber: 16-1/8" (H) x 18-1/8" (W) x 33" (D)
41 cm (H) x 46 cm (W) x 84 cm (D)
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Drying Cabinet
The model 45 dramatically reduces the time required to dry inhalation therapyand anesthesia equipment to between one-half and three hours.
• Capacity for drying 45 tubes from 6 mm (1/4 in.) to 44 mm (1-3/4 in.) indiameter at one time
• Removable wire basket for drying small parts in one-half of the cabinet, whiledrying tubing in the other half
• Capacity for holding four baskets— two deep on each side of the cabinet ortwo double baskets across the cabinet
• Dries tubes in a fraction of the time
3M™ Steri-Vac™ Drying Cabinet
Cat. # Description Shipping
45AA Drying Cabinet with wall mounting bracket 1 unit/case68-7/8" (H) x 22-3/8" (W) x 15-1/2" (D)175 cm (H) x 57 cm (W) x 42 cm (D)
41
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
The abator removes EO gas exhausted from 3M™ Steri-Vac™ sterilizers and aerators, converting it into CO2 and water vapor. At normal operatingtemperatures and concentrations, removal efficiency is 99.9+%.
• Works automatically with sterilization system
• Interfaces with up to two sterilizers
3M™ EtO-Abator System
Cat. # Description Shipping
50SCFM Abator 1 unit/case31" (H) x 32" (W) x 41" (D)80 cm (H) x 82 cm (W) x 105 cm (D)
3M™ EtO-Abator System
40
39390 catalog 3.qxd 4/12/02 4:19 PM Page 36
Ste r i l i za t i on Assu rance
39
STER
ILIZ
ATIO
N HA
RDW
ARE
CLEA
NING
AND
DEC
ONTA
MIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RSS t e r i l i za t i on Assu rance
38
STER
ILIZ
ATIO
N HA
RDW
ARE
CLEA
NING
AND
DEC
ONTA
MIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
3M™ Steri-Lok™ Closure Tape
Cat. # Description Packaging Shipping
1225 White flatback paper tape 18 rolls/case case1 in. x 60 yd. (2,5 cm x 55 m)
3M™ Steri-Lok™ Peel Open Packages for EO Gas Sterilization (Film/Tyvek)
Cat. # Description Packaging Shipping
8501 3-1/8 in. x 7-7/8 in. (7,9 cm x 20 cm) 250 each/box 4 boxes/case
8502 3-7/8 in. x 9-3/4 in. (7,9 cm x 24,8 cm) 250 each/box 4 boxes/case
8503 5-7/8 in. x 9-3/4 in. (14,9 cm x 24,8 cm) 250 each/box 4 boxes/case
8504 3-1/8 in. x 24 in. (7,9 cm x 61 cm) 250 each/box 4 boxes/case
8505 7 in. x 13 in. (17,8 x 33 cm) 250 each/box 2 boxes/case
8506 11-3/4 in. x 14-7/8 in. (29,8 cm x 38 cm) 250 each/box 2 boxes/case
8507 15-3/4 in. x 18 in. (40 cm x 45,7 cm) 250 each/box 2 boxes/case
3M™ Steri-Lok™ Polyethylene Bags for EO Gas Sterilization
Cat. # Description Packaging Shipping
8250 3-1/4 in. x 5-1/2 in. (8,3 cm x 14 cm) 100 each/pack 5 packs/case
8251 7 in. x 13 in. (17,8 cm x 33 cm) 100 each/pack 5 packs/case
8252 9 in. x 17 in. (22,9 cm x 43,2 cm) 100 each/pack 5 packs/case
8253 12 in. x 15 in. (30,5 cm x 38 cm) 100 each/pack 5 packs/case
8254 15 in. x 23 in. (38 cm x 58,4 cm) 100 each/pack 5 packs/case
8255 20 in. x 30 in. (50,9 cm x 76 cm) 50 each/pack 5 packs/case
3M™ Steri-Lok™ Polyethylene Tubes for EO Gas Sterilization
Cat. # Description Packaging Shipping
8203 3 in. x 75 ft. (7,6 cm x 22,9 m) 1 each/box 4 boxes/case
8205 5 in. x 75 ft. (12,7 cm x 22,9 m) 1 each/box 4 boxes/case
8210 10 in. x 75 ft. (25,4 cm x 22,9 m) 1 each/box 4 boxes/case
8220 20 in. x 75 ft. (50,9 cm x 22,9 m) 1 each/box 4 boxes/case
Packaging
44
EO Monitoring Badge
Lightweight badge packed with ethylene oxide-sensitive material. Clips to lapel or pocket near breathing zone for passive monitoring of individual during a work shift. Monitor is mailed for analysis. Report is mailed to user (or telephoned if permissible exposure limits are exceeded).
3M™ EO Monitoring Badge
Cat. # Description Packaging Shipping
3550 EO Monitoring Badge - 5 each/case
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
45
Printer Paper
3M™ Steri-Vac™ Printer Paper
Cat. # Description Shipping
1215A Printer Paper, 51 mm (2 inch) wide, 2 rolls/casefor models 400B & 400C
1216A Printer Paper, 60 mm (2-3/8 inch) wide, 2 rolls/casefor 4XL and 5XL (w ser# below 720000)
1217 Printer Paper, 79 mm (3-1/8 inch) wide, 2 rolls/casefor 8XL and 5XL (w ser# above 720000)
EO Gas Cartridges
100% ethylene oxide (EO) is contained in a single-dose cartridge. The cartridge contains 3.5, 4.5 or 6 oz. of EO depending on the model Steri-Vac sterilizer used.
• The system provides an easy, cost-effective and efficient method of gas sterilization
• Only small amounts of ethylene oxide are contained in the cartridges
• Precise usage of EO with single-dose cartridges means no waste of sterilant
• With Steri-Gas cartridges, operators have no bulky, heavy gas tanks to handle,and no hoses, valves and filters to adjust or replace
• The cartridges do not contain CFCs or HCFCs
3M™ Steri-Gas™ Cartridges
Cat. # Description Packaging Shipping
4-100 100 gram cartridge for models 400C, 4XL and 5XL 12 each/box 4 boxes/case
4-134 127 gram cartridge for model 400B 12 each/box 4 boxes/case
8-170 170 gram cartridge for model 8XL 12 each/box 4 boxes/case
43
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
39390 catalog 3.qxd 4/12/02 4:19 PM Page 38
Ste r i l i za t i on Assu rance
39
STER
ILIZ
ATIO
N HA
RDW
ARE
CLEA
NING
AND
DEC
ONTA
MIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RSS t e r i l i za t i on Assu rance
38
STER
ILIZ
ATIO
N HA
RDW
ARE
CLEA
NING
AND
DEC
ONTA
MIN
ATIO
N
R
ECOR
DKE
EPIN
G
IN
DICA
TOR
TAPE
S
B
OWIE
-DIC
K TE
ST P
ACKS
CHE
MIC
ALIN
DICA
TORS
ENZ
YMAT
IC IN
DICA
TORS
BIO
LOGI
CAL
INDI
CATO
RS
3M™ Steri-Lok™ Closure Tape
Cat. # Description Packaging Shipping
1225 White flatback paper tape 18 rolls/case case1 in. x 60 yd. (2,5 cm x 55 m)
3M™ Steri-Lok™ Peel Open Packages for EO Gas Sterilization (Film/Tyvek)
Cat. # Description Packaging Shipping
8501 3-1/8 in. x 7-7/8 in. (7,9 cm x 20 cm) 250 each/box 4 boxes/case
8502 3-7/8 in. x 9-3/4 in. (7,9 cm x 24,8 cm) 250 each/box 4 boxes/case
8503 5-7/8 in. x 9-3/4 in. (14,9 cm x 24,8 cm) 250 each/box 4 boxes/case
8504 3-1/8 in. x 24 in. (7,9 cm x 61 cm) 250 each/box 4 boxes/case
8505 7 in. x 13 in. (17,8 x 33 cm) 250 each/box 2 boxes/case
8506 11-3/4 in. x 14-7/8 in. (29,8 cm x 38 cm) 250 each/box 2 boxes/case
8507 15-3/4 in. x 18 in. (40 cm x 45,7 cm) 250 each/box 2 boxes/case
3M™ Steri-Lok™ Polyethylene Bags for EO Gas Sterilization
Cat. # Description Packaging Shipping
8250 3-1/4 in. x 5-1/2 in. (8,3 cm x 14 cm) 100 each/pack 5 packs/case
8251 7 in. x 13 in. (17,8 cm x 33 cm) 100 each/pack 5 packs/case
8252 9 in. x 17 in. (22,9 cm x 43,2 cm) 100 each/pack 5 packs/case
8253 12 in. x 15 in. (30,5 cm x 38 cm) 100 each/pack 5 packs/case
8254 15 in. x 23 in. (38 cm x 58,4 cm) 100 each/pack 5 packs/case
8255 20 in. x 30 in. (50,9 cm x 76 cm) 50 each/pack 5 packs/case
3M™ Steri-Lok™ Polyethylene Tubes for EO Gas Sterilization
Cat. # Description Packaging Shipping
8203 3 in. x 75 ft. (7,6 cm x 22,9 m) 1 each/box 4 boxes/case
8205 5 in. x 75 ft. (12,7 cm x 22,9 m) 1 each/box 4 boxes/case
8210 10 in. x 75 ft. (25,4 cm x 22,9 m) 1 each/box 4 boxes/case
8220 20 in. x 75 ft. (50,9 cm x 22,9 m) 1 each/box 4 boxes/case
Packaging
44
EO Monitoring Badge
Lightweight badge packed with ethylene oxide-sensitive material. Clips to lapel or pocket near breathing zone for passive monitoring of individual during a work shift. Monitor is mailed for analysis. Report is mailed to user (or telephoned if permissible exposure limits are exceeded).
3M™ EO Monitoring Badge
Cat. # Description Packaging Shipping
3550 EO Monitoring Badge - 5 each/case
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
45
Printer Paper
3M™ Steri-Vac™ Printer Paper
Cat. # Description Shipping
1215A Printer Paper, 51 mm (2 inch) wide, 2 rolls/casefor models 400B & 400C
1216A Printer Paper, 60 mm (2-3/8 inch) wide, 2 rolls/casefor 4XL and 5XL (w ser# below 720000)
1217 Printer Paper, 79 mm (3-1/8 inch) wide, 2 rolls/casefor 8XL and 5XL (w ser# above 720000)
EO Gas Cartridges
100% ethylene oxide (EO) is contained in a single-dose cartridge. The cartridge contains 3.5, 4.5 or 6 oz. of EO depending on the model Steri-Vac sterilizer used.
• The system provides an easy, cost-effective and efficient method of gas sterilization
• Only small amounts of ethylene oxide are contained in the cartridges
• Precise usage of EO with single-dose cartridges means no waste of sterilant
• With Steri-Gas cartridges, operators have no bulky, heavy gas tanks to handle,and no hoses, valves and filters to adjust or replace
• The cartridges do not contain CFCs or HCFCs
3M™ Steri-Gas™ Cartridges
Cat. # Description Packaging Shipping
4-100 100 gram cartridge for models 400C, 4XL and 5XL 12 each/box 4 boxes/case
4-134 127 gram cartridge for model 400B 12 each/box 4 boxes/case
8-170 170 gram cartridge for model 8XL 12 each/box 4 boxes/case
43
Issue/UseStoreSterilizePrep/PackClean/Decontaminate
39390 catalog 3.qxd 4/12/02 4:19 PM Page 38
I ndex
41
00107 3M™ Comply™ Steam Chemical Indicator Strip 16
00107A 3M™ Comply™ Steam Chemical Indicator Strip 16
00109 3M™ Comply™ Steam Chemical Indicator Strip 16
00109A 3M™ Comply™ Steam Chemical Indicator Strip 16
00117 3M™ Comply™ Steam Chemical Indicator-Plus Strip 15
00118 3M™ Comply™ Steam Chemical Indicator Plus Strip 15
00119 3M™ Comply™ Steam Chemical Indicator Plus Strip 15
00130 3M™ Comply™ Bowie-Dick Test Sheets 23
00135 3M™ Comply™ Bowie-Dick Plus Test Pack with Early Warning Test Sheet 23
00152 3M™ Comply™ EO Chemical Indicator Strip 18
00155 3M™ Comply™ EO Chemical Indicator Strip 18
00160 3M™ Comply™ Chemical Indicator Label 21
00162 3M™ Comply™ Chemical Indicator Label 21
00170 3M™ Comply™ Chemical Indicator Label 21
4-100 3M™ Steri-Gas™ Cartridge 38
4-134 3M™ Steri-Gas™ Cartridge 38
8-170 3M™ Steri-Gas™ Cartridge 38
4XL 3M™ Steri-Vac™ 4XL Sterilizer/Aerator 35
5XL 3M™ Steri-Vac™ 5XL Sterilizer/Aerator 35
8XL 3M™ Steri-Vac™ 8XL Sterilizer/Aerator 35
45AA 3M™ Steri-Vac™ Drying Cabinet 37
50SCFM 3M™ EtO-Abator System 36
115 3M™ Attest™ Biological Indicator Monitoring Starter Kit 10
116 3M™ Attest™ Biological Indicator Incubator 10
117 3M™ Attest™ Biological Indicator Incubator 10
126 3M™ Attest™ Biological Indicator Incubator 10
127 3M™ Attest™ Biological Indicator Incubator 10
130 3M™ Attest™ Biological Indicator Incubator 10
190 3M™ Attest™ 190 Auto-reader 8
290 3M™ Attest™ 290 Auto-reader 8
1201 3M™ Comply™ Indicator Roll (Steam) 16
1202 3M™ Comply™ Indicator Roll (EO) 18
1206 1206 Tape Dispenser 27
1215A 3M™ Steri-Vac™ Printer Paper 38
1216A 3M™ Steri-Vac™ Printer Paper 38
1217 3M™ Steri-Vac™ Printer Paper 38
1222-0N 3M™ Comply™ Indicator Tape for Steam Sterilization 25
1222-1N 3M™ Comply™ Indicator Tape for Steam Sterilization 25
1222-2N 3M™ Comply™ Indicator Tape for Steam Sterilization 25
1222-6N 3M™ Comply™ Indicator Tape for Steam Sterilization 25
1224-0 3M™ Comply™ Indicator Tape for Ethylene Oxide Sterilization 26
1224-1 3M™ Comply™ Indicator Tape for Ethylene Oxide Sterilization 26
1224-6 3M™ Comply™ Indicator Tape for Ethylene Oxide Sterilization 26
1233 3M™ Comply™ Bowie-Dick Type Test Pack 23
1240E 3M™ Comply™ (SteriGage™) Integrator Extender 15 &17
Index by Catalog Number
Catalog Number Product Name Page Number
Index
39390 catalog 3.qxd 4/12/02 4:20 PM Page 40
I ndex
41
00107 3M™ Comply™ Steam Chemical Indicator Strip 16
00107A 3M™ Comply™ Steam Chemical Indicator Strip 16
00109 3M™ Comply™ Steam Chemical Indicator Strip 16
00109A 3M™ Comply™ Steam Chemical Indicator Strip 16
00117 3M™ Comply™ Steam Chemical Indicator-Plus Strip 15
00118 3M™ Comply™ Steam Chemical Indicator Plus Strip 15
00119 3M™ Comply™ Steam Chemical Indicator Plus Strip 15
00130 3M™ Comply™ Bowie-Dick Test Sheets 23
00135 3M™ Comply™ Bowie-Dick Plus Test Pack with Early Warning Test Sheet 23
00152 3M™ Comply™ EO Chemical Indicator Strip 18
00155 3M™ Comply™ EO Chemical Indicator Strip 18
00160 3M™ Comply™ Chemical Indicator Label 21
00162 3M™ Comply™ Chemical Indicator Label 21
00170 3M™ Comply™ Chemical Indicator Label 21
4-100 3M™ Steri-Gas™ Cartridge 38
4-134 3M™ Steri-Gas™ Cartridge 38
8-170 3M™ Steri-Gas™ Cartridge 38
4XL 3M™ Steri-Vac™ 4XL Sterilizer/Aerator 35
5XL 3M™ Steri-Vac™ 5XL Sterilizer/Aerator 35
8XL 3M™ Steri-Vac™ 8XL Sterilizer/Aerator 35
45AA 3M™ Steri-Vac™ Drying Cabinet 37
50SCFM 3M™ EtO-Abator System 36
115 3M™ Attest™ Biological Indicator Monitoring Starter Kit 10
116 3M™ Attest™ Biological Indicator Incubator 10
117 3M™ Attest™ Biological Indicator Incubator 10
126 3M™ Attest™ Biological Indicator Incubator 10
127 3M™ Attest™ Biological Indicator Incubator 10
130 3M™ Attest™ Biological Indicator Incubator 10
190 3M™ Attest™ 190 Auto-reader 8
290 3M™ Attest™ 290 Auto-reader 8
1201 3M™ Comply™ Indicator Roll (Steam) 16
1202 3M™ Comply™ Indicator Roll (EO) 18
1206 1206 Tape Dispenser 27
1215A 3M™ Steri-Vac™ Printer Paper 38
1216A 3M™ Steri-Vac™ Printer Paper 38
1217 3M™ Steri-Vac™ Printer Paper 38
1222-0N 3M™ Comply™ Indicator Tape for Steam Sterilization 25
1222-1N 3M™ Comply™ Indicator Tape for Steam Sterilization 25
1222-2N 3M™ Comply™ Indicator Tape for Steam Sterilization 25
1222-6N 3M™ Comply™ Indicator Tape for Steam Sterilization 25
1224-0 3M™ Comply™ Indicator Tape for Ethylene Oxide Sterilization 26
1224-1 3M™ Comply™ Indicator Tape for Ethylene Oxide Sterilization 26
1224-6 3M™ Comply™ Indicator Tape for Ethylene Oxide Sterilization 26
1233 3M™ Comply™ Bowie-Dick Type Test Pack 23
1240E 3M™ Comply™ (SteriGage™) Integrator Extender 15 &17
Index by Catalog Number
Catalog Number Product Name Page Number
Index
39390 catalog 3.qxd 4/12/02 4:20 PM Page 40
I ndex
43
I ndex
42
1269G Event Related Sterilization Record Labels—“Sterilized” 31
1269R Event Related Sterilization Record Labels—“Sterilized” 31
1276 3M™ Attest™ Biological Indicator Test Pack for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizer 9
1276F 3M™ Attest™ Biological Indicator Test Pack for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizer 9
1278 3M™ Attest™ Biological Indicator Test Pack for Ethylene Oxide 9
1278F 3M™ Attest™ Biological Indicator Test Pack for Ethylene Oxide 9
1283 3M™ Glutaraldehyde Log Book 29
1283S Replacement Sheets for 1283 Log Book 29
1291 3M™ Attest™ Rapid Readout Biological Indicator for 270°F/132°C Gravity Displacement Steam Sterilizer 7
1292 3M™ Attest™ Rapid Readout Biological Indicator for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizer 7
1296 3M™ Attest™ Rapid Readout Biological Indicator Test Pack for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizer 7
1296F 3M™ Attest™ Rapid Readout Biological Indicator Test Pack for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizer 7
13911 3M™ Comply™ Instrument Protector 21
13913 3M™ Comply™ Instrument Protector 21
13915 3M™ Comply™ Instrument Protector 21
2482 3M™ Enzymatic Indicators 12
2482T 3M™ Enzymatic Indicators 12
2482F 3M™ Enzymatic Indicators 12
2483 3M™ Challenge Packs 12
2486 3M™ Enzymatic Indicators and Challenge Packs 12
2486F 3M™ Enzymatic Indicators and Challenge Packs 12
3550 3M™ EO Monitoring Badge 39
3552 3M™ Comply™ Glutaraldehyde Monitor 20
3553 3M™ Comply™ Glutaraldehyde Monitor 20
3983MM 3M™ Comply™ Glutaraldehyde Monitor, 1.5% 20
3987 3M™ Comply™ Glutaraldehyde Monitor, 1.8% 20
3989 3M™ Comply™ Glutaraldehyde Monitor, 2.1% 20
41360 3M™ Comply™ (SteriGage™) Steam Chemical Integrator Test Pack 14
41380 3M™ Attest™ Steam-Plus Test Pack 9
4171MM 3M™ Comply™ Load Record Cards 30
45260 3M™ Comply™ (SteriGage™) EO Chemical Integrator Test Pack 14
6010 3M™ Transfer Cart 37
67200 3M™ Comply™ Load Record Cards (Steam and EO) 30
67201 3M™ Comply™ Load Record Cards (Steam and EO) 30
70500-B 3M™ Rapid Multi-Enzyme Detergent, 5 liter bottle 33
70500-D 3M™ Rapid Multi-Enzyme Detergent, 1 liter bottle 33
70500-H 3M™ Rapid Multi-Enzyme Detergent, 100 ml bottle 33
78-2007-2981-5 3M™ Attest™ 290 Auto-reader Power Cord 8
78-8078-7349-8 3M™ Attest™ 190 Auto-reader UV Bulb and Starter Kit 8
8203 3M™ Steri-Lok™ Polyethylene Tube for EO Gas Sterilization, 3 in. x 75 ft. (7,6 cm x 2287,5 cm) 39
Index by Catalog Number
Catalog Number Product Name Page Number
1243A 3M™ Comply™ (SteriGage™) Steam Chemical Integrator 15
1243B 3M™ Comply™ (SteriGage™) Steam Chemical Integrator 15
1243E 3M™ Comply™ (SteriGage™) Steam Chemical Integrator 15
1244A 3M™ Comply™ (SteriGage™) EO Chemical Integrator 17
1244B 3M™ Comply™ (SteriGage™) EO Chemical Integrator 17
1244E 3M™ Comply™ (SteriGage™) EO Chemical Integrator 17
1248 3M™ Comply™ Gas Plasma Chemical Indicator Strip 17
1249 3M™ Comply™ Liquid Peracetic Acid Chemical Indicator 17
1250 3M™ Comply™ Steam Chemical Indicator Strip 16
1251 3M™ Comply™ EO Chemical Indicator Strip 18
1252 3M™ Comply™ Load Record Card (Steam) 30
1253 3M™ Comply™ Load Record Card (EO) 30
1254B 3M™ Sterilization Log Book for Envelopes 29
1254E-F Flash Envelopes for 1254B Log Book 29
1254E-LT Low Temperature Envelopes for 1254B Log Book 29
1254E-S Steam Envelopes for 1254B Log Book 29
1255-1N 3M™ Comply™ Steam Indicator Tape for Disposable Wrap 26
1255-6N 3M™ Comply™ Steam Indicator Tape for Disposable Wrap 26
1256B 3M™ Comply™ Label Gun 31
1257B Sterilization Record Labels—“Expires” 31
1257BL Sterilization Record Labels—“Expires” 31
1257BR Sterilization Record Labels—“Expires” 31
1257G Sterilization Record Labels—“Expires” 31
1257GD Sterilization Record Labels—“Expires” 31
1257GY Sterilization Record Labels—“Expires” 31
1257OR Sterilization Record Labels—“Expires” 31
1257P Sterilization Record Labels—“Expires” 31
1257PK Sterilization Record Labels—“Expires” 31
1257R Sterilization Record Labels—“Expires” 31
1257W Sterilization Record Labels—Blank 31
1257Y Sterilization Record Labels—“Expires” 31
1261 3M™ Attest™ Biological Indicator for 270°F/132°C Gravity Displacement Steam Sterilizer 9
1261P 3M™ Attest™ Biological Indicator for 270°F/132°C Gravity Displacement Steam Sterilizer 9
1262 3M™ Attest™ Biological Indicator for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizer 9
1262P 3M™ Attest™ Biological Indicator for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizer 9
1264 3M™ Attest™ Biological Indicator for Ethylene Oxide 9
1264P 3M™ Attest™ Biological Indicator for Ethylene Oxide 9
1266 3M™ Steam Log Book 29
1266S Replacement Sheet for 1266 Log Book 29
1268 3M™ Low Temperature Log Book 29
1268S Replacement Sheet for 1268 Log Book 29
1269B Event Related Sterilization Record Labels—“Sterilized” 31
1269BL Event Related Sterilization Record Labels—“Sterilized” 31
Index by Catalog Number
Catalog Number Product Name Page Number
39390 catalog 3.qxd 4/12/02 4:20 PM Page 42
I ndex
43
I ndex
42
1269G Event Related Sterilization Record Labels—“Sterilized” 31
1269R Event Related Sterilization Record Labels—“Sterilized” 31
1276 3M™ Attest™ Biological Indicator Test Pack for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizer 9
1276F 3M™ Attest™ Biological Indicator Test Pack for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizer 9
1278 3M™ Attest™ Biological Indicator Test Pack for Ethylene Oxide 9
1278F 3M™ Attest™ Biological Indicator Test Pack for Ethylene Oxide 9
1283 3M™ Glutaraldehyde Log Book 29
1283S Replacement Sheets for 1283 Log Book 29
1291 3M™ Attest™ Rapid Readout Biological Indicator for 270°F/132°C Gravity Displacement Steam Sterilizer 7
1292 3M™ Attest™ Rapid Readout Biological Indicator for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizer 7
1296 3M™ Attest™ Rapid Readout Biological Indicator Test Pack for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizer 7
1296F 3M™ Attest™ Rapid Readout Biological Indicator Test Pack for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizer 7
13911 3M™ Comply™ Instrument Protector 21
13913 3M™ Comply™ Instrument Protector 21
13915 3M™ Comply™ Instrument Protector 21
2482 3M™ Enzymatic Indicators 12
2482T 3M™ Enzymatic Indicators 12
2482F 3M™ Enzymatic Indicators 12
2483 3M™ Challenge Packs 12
2486 3M™ Enzymatic Indicators and Challenge Packs 12
2486F 3M™ Enzymatic Indicators and Challenge Packs 12
3550 3M™ EO Monitoring Badge 39
3552 3M™ Comply™ Glutaraldehyde Monitor 20
3553 3M™ Comply™ Glutaraldehyde Monitor 20
3983MM 3M™ Comply™ Glutaraldehyde Monitor, 1.5% 20
3987 3M™ Comply™ Glutaraldehyde Monitor, 1.8% 20
3989 3M™ Comply™ Glutaraldehyde Monitor, 2.1% 20
41360 3M™ Comply™ (SteriGage™) Steam Chemical Integrator Test Pack 14
41380 3M™ Attest™ Steam-Plus Test Pack 9
4171MM 3M™ Comply™ Load Record Cards 30
45260 3M™ Comply™ (SteriGage™) EO Chemical Integrator Test Pack 14
6010 3M™ Transfer Cart 37
67200 3M™ Comply™ Load Record Cards (Steam and EO) 30
67201 3M™ Comply™ Load Record Cards (Steam and EO) 30
70500-B 3M™ Rapid Multi-Enzyme Detergent, 5 liter bottle 33
70500-D 3M™ Rapid Multi-Enzyme Detergent, 1 liter bottle 33
70500-H 3M™ Rapid Multi-Enzyme Detergent, 100 ml bottle 33
78-2007-2981-5 3M™ Attest™ 290 Auto-reader Power Cord 8
78-8078-7349-8 3M™ Attest™ 190 Auto-reader UV Bulb and Starter Kit 8
8203 3M™ Steri-Lok™ Polyethylene Tube for EO Gas Sterilization, 3 in. x 75 ft. (7,6 cm x 2287,5 cm) 39
Index by Catalog Number
Catalog Number Product Name Page Number
1243A 3M™ Comply™ (SteriGage™) Steam Chemical Integrator 15
1243B 3M™ Comply™ (SteriGage™) Steam Chemical Integrator 15
1243E 3M™ Comply™ (SteriGage™) Steam Chemical Integrator 15
1244A 3M™ Comply™ (SteriGage™) EO Chemical Integrator 17
1244B 3M™ Comply™ (SteriGage™) EO Chemical Integrator 17
1244E 3M™ Comply™ (SteriGage™) EO Chemical Integrator 17
1248 3M™ Comply™ Gas Plasma Chemical Indicator Strip 17
1249 3M™ Comply™ Liquid Peracetic Acid Chemical Indicator 17
1250 3M™ Comply™ Steam Chemical Indicator Strip 16
1251 3M™ Comply™ EO Chemical Indicator Strip 18
1252 3M™ Comply™ Load Record Card (Steam) 30
1253 3M™ Comply™ Load Record Card (EO) 30
1254B 3M™ Sterilization Log Book for Envelopes 29
1254E-F Flash Envelopes for 1254B Log Book 29
1254E-LT Low Temperature Envelopes for 1254B Log Book 29
1254E-S Steam Envelopes for 1254B Log Book 29
1255-1N 3M™ Comply™ Steam Indicator Tape for Disposable Wrap 26
1255-6N 3M™ Comply™ Steam Indicator Tape for Disposable Wrap 26
1256B 3M™ Comply™ Label Gun 31
1257B Sterilization Record Labels—“Expires” 31
1257BL Sterilization Record Labels—“Expires” 31
1257BR Sterilization Record Labels—“Expires” 31
1257G Sterilization Record Labels—“Expires” 31
1257GD Sterilization Record Labels—“Expires” 31
1257GY Sterilization Record Labels—“Expires” 31
1257OR Sterilization Record Labels—“Expires” 31
1257P Sterilization Record Labels—“Expires” 31
1257PK Sterilization Record Labels—“Expires” 31
1257R Sterilization Record Labels—“Expires” 31
1257W Sterilization Record Labels—Blank 31
1257Y Sterilization Record Labels—“Expires” 31
1261 3M™ Attest™ Biological Indicator for 270°F/132°C Gravity Displacement Steam Sterilizer 9
1261P 3M™ Attest™ Biological Indicator for 270°F/132°C Gravity Displacement Steam Sterilizer 9
1262 3M™ Attest™ Biological Indicator for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizer 9
1262P 3M™ Attest™ Biological Indicator for 250°F/121°C Gravity and 270°F/132°C Vacuum-Assisted Steam Sterilizer 9
1264 3M™ Attest™ Biological Indicator for Ethylene Oxide 9
1264P 3M™ Attest™ Biological Indicator for Ethylene Oxide 9
1266 3M™ Steam Log Book 29
1266S Replacement Sheet for 1266 Log Book 29
1268 3M™ Low Temperature Log Book 29
1268S Replacement Sheet for 1268 Log Book 29
1269B Event Related Sterilization Record Labels—“Sterilized” 31
1269BL Event Related Sterilization Record Labels—“Sterilized” 31
Index by Catalog Number
Catalog Number Product Name Page Number
39390 catalog 3.qxd 4/12/02 4:20 PM Page 42
I ndex
44
8205 3M™ Steri-Lok™ Polyethylene Tube for EO Gas Sterilization, 5 in. x 75 ft. (12,7 cm x 2287,5 cm) 39
8210 3M™ Steri-Lok™ Polyethylene Tube for EO Gas Sterilization, 10 in. x 75 ft. (25,4 cm x 2287,5 cm) 39
8220 3M™ Steri-Lok™ Polyethylene Tube for EO Gas Sterilization, 205 in. x 75 ft. (50,9 cm x 2287,5 cm) 39
8250 3M™ Steri-Lok™ Polyethylene Bags for EO Gas Sterilization, 3-1/4 in. x 5-1/2 in. (8,3 cm x 14 cm) 39
8251 3M™ Steri-Lok™ Polyethylene Bags for EO Gas Sterilization, 7 in. x 13 in. (17,8 cm x 33 cm) 39
8252 3M™ Steri-Lok™ Polyethylene Bag for EO Gas Sterilization, 9 in. x 17 in. (22,9 cm x 43,2 cm) 39
8253 3M™ Steri-Lok™ Polyethylene Bag for EO Gas Sterilization, 12 in. x 15 in. (30,5 cm x 38 cm) 39
8254 3M™ Steri-Lok™ Polyethylene Bag for EO Gas Sterilization, 15 in. x 23 in. (38 cm x 58,4 cm) 39
8255 3M™ Steri-Lok™ Polyethylene Bag for EO Gas Sterilization, 20 in. x 30 in. (50,9 cm x 76 cm) 39
8501 3M™ Steri-Lok™ Peel Open Package for EO Gas Sterilization, 3-1/8 in. x 7-7/8 in. (7,9 cm x 20 cm) 39
8502 3M™ Steri-Lok™ Peel Open Package for EO Gas Sterilization, 3-7/8 in. x 9-3/4 in. (7,9 cm x 24,8 cm) 39
8503 3M™ Steri-Lok™ Peel Open Package for EO Gas Sterilization, 5-7/8 in. x 9-3/4 in. (14,9 cm x 24,8 cm) 39
8504 3M™ Steri-Lok™ Peel Open Package for EO Gas Sterilization, 3-1/8 in. x 24 in. (7,9 cm x 61 cm) 39
8505 3M™ Steri-Lok™ Peel Open Package for EO Gas Sterilization, 7 in. x 13 in. (17,8 cm x 33 cm) 39
8506 3M™ Steri-Lok™ Peel Open Package for EO Gas Sterilization, 11-3/4 in. x 14-7/8 in. (29,8 cm x 38 cm) 39
8507 3M™ Steri-Lok™ Peel Open Package for EO Gas Sterilization, 15-3/4 in. x 18 in. (40 cm x 45,7 cm) 39
C22 C-22 Heavy Duty Tape Dispenser 27
M51 M51/M51-T Tape Dispenser without tabber 27
M51-T M51/M51-T Tape Dispenser with tabber 27
M920 M920 Definite-Length Tape Dispenser 27
M96 M96 Definite-Length Tape Dispenser 27
XL 3M™ Steri-Vac™ XL Aerator 36
Index by Catalog Number
Catalog Number Product Name Page Number
39390 catalog 3.qxd 4/12/02 4:20 PM Page 44
I ndex
44
8205 3M™ Steri-Lok™ Polyethylene Tube for EO Gas Sterilization, 5 in. x 75 ft. (12,7 cm x 2287,5 cm) 39
8210 3M™ Steri-Lok™ Polyethylene Tube for EO Gas Sterilization, 10 in. x 75 ft. (25,4 cm x 2287,5 cm) 39
8220 3M™ Steri-Lok™ Polyethylene Tube for EO Gas Sterilization, 205 in. x 75 ft. (50,9 cm x 2287,5 cm) 39
8250 3M™ Steri-Lok™ Polyethylene Bags for EO Gas Sterilization, 3-1/4 in. x 5-1/2 in. (8,3 cm x 14 cm) 39
8251 3M™ Steri-Lok™ Polyethylene Bags for EO Gas Sterilization, 7 in. x 13 in. (17,8 cm x 33 cm) 39
8252 3M™ Steri-Lok™ Polyethylene Bag for EO Gas Sterilization, 9 in. x 17 in. (22,9 cm x 43,2 cm) 39
8253 3M™ Steri-Lok™ Polyethylene Bag for EO Gas Sterilization, 12 in. x 15 in. (30,5 cm x 38 cm) 39
8254 3M™ Steri-Lok™ Polyethylene Bag for EO Gas Sterilization, 15 in. x 23 in. (38 cm x 58,4 cm) 39
8255 3M™ Steri-Lok™ Polyethylene Bag for EO Gas Sterilization, 20 in. x 30 in. (50,9 cm x 76 cm) 39
8501 3M™ Steri-Lok™ Peel Open Package for EO Gas Sterilization, 3-1/8 in. x 7-7/8 in. (7,9 cm x 20 cm) 39
8502 3M™ Steri-Lok™ Peel Open Package for EO Gas Sterilization, 3-7/8 in. x 9-3/4 in. (7,9 cm x 24,8 cm) 39
8503 3M™ Steri-Lok™ Peel Open Package for EO Gas Sterilization, 5-7/8 in. x 9-3/4 in. (14,9 cm x 24,8 cm) 39
8504 3M™ Steri-Lok™ Peel Open Package for EO Gas Sterilization, 3-1/8 in. x 24 in. (7,9 cm x 61 cm) 39
8505 3M™ Steri-Lok™ Peel Open Package for EO Gas Sterilization, 7 in. x 13 in. (17,8 cm x 33 cm) 39
8506 3M™ Steri-Lok™ Peel Open Package for EO Gas Sterilization, 11-3/4 in. x 14-7/8 in. (29,8 cm x 38 cm) 39
8507 3M™ Steri-Lok™ Peel Open Package for EO Gas Sterilization, 15-3/4 in. x 18 in. (40 cm x 45,7 cm) 39
C22 C-22 Heavy Duty Tape Dispenser 27
M51 M51/M51-T Tape Dispenser without tabber 27
M51-T M51/M51-T Tape Dispenser with tabber 27
M920 M920 Definite-Length Tape Dispenser 27
M96 M96 Definite-Length Tape Dispenser 27
XL 3M™ Steri-Vac™ XL Aerator 36
Index by Catalog Number
Catalog Number Product Name Page Number
39390 catalog 3.qxd 4/12/02 4:20 PM Page 44
3M Infection
Prevention
TM
SterilizationAssurance
SkinPrep
Sterile Field & Surface
EnvironmentalCleaning
WoundManagement
A full line of innovative products that enhance patientoutcomes and help manage health care costs.
3Health Care
3M Center, Building 275-4W-02St. Paul, MN 55144-1000 USA1 800 [email protected]/healthcare
3M Canada
Post Office Box 5757London, Ontario N6A 4T1Canada1 800 563-2921
Minimum 10% Post-Consumer Fiber
Steris System 1 is a registeredtrademark of Steris Corporation.STERRAD is a registered trademarkof Johnson & Johnson, Inc.
H.I. 4509Printed in U.S.A.© 3M 2002 All Rights Reserved70-2009-0360-0
39390 catalog 3.qxd 4/12/02 4:20 PM Page 46