3ka - engnet...iec 60068-1 • connection: tunnel terminals for the following cables: • 16 2mm...
TRANSCRIPT
Type Rating (A) Width in mod.of 9mm
Catalogue numberC curve
1P
6 2 60811
10 2 60812
16 2 60813
20 2 60814
25 2 60815
32 2 60816
40 2 60817
50 2 60818
63 2 60819
2P
6 4 60821
10 4 60822
16 4 60823
20 4 60824
25 4 60825
32 4 60826
40 4 60827
50 4 60828
63 4 60829
3P
6 6 60831
10 6 60832
16 6 60833
20 6 60834
25 6 60835
32 6 60836
40 6 60837
50 6 60838
63 6 60839
4P
6 8 60841
10 8 60842
16 8 60843
20 8 60844
25 8 60845
32 8 60846
40 8 60847
50 8 60848
63 8 60849
Poles Rating (A) Sensitivity (mA)
Voltage(V)
Width in modules of 9mm
References
2P
25 30 240 4 11617
40 30 240 4 11618
63 30 240 4 11619
Schneider Electric RSA1 Riverview Office Park, Janadel AvenueHalfway Gardens, Midrand
Tel +27 11 254 6400Fax +27 11 254 6640www.schneider-electric.co.za
Residential circuit breaker range
As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication.
© 2
01
0 S
chne
ider
Ele
ctri
c -
All
rig
hts
rese
rved
>Schneider Electric not only has the most comprehensive product range in South Africa but we also have the largest distributor network with over 200 authorised outlets. To find your nearest authorised distributor call any one of our offices, alternatively go to our web site www.schneider-electric.co.za, click on “where to buy our products” and find your nearest outlet.
3kAResidential DIN circuit breaker range
Isolator type earth leakage protection devices
3kA Z-Folded Leaflet Rev1.indd 1 2012/02/24 11:15:44 AM
Please remember to ask your distributor about the:
Earth Leakage Special
Miniature Circuit Breaker RangeComplete DIN rail offer for the residential market
The range consists of DIN rail mountable miniature circuit breakers with 1P, 2P, 3P and 4P.
The MCB’s combine the
following features:• Protectionofpersonsagainst
indirectcontactwithTNandIT
earthingsystems
• Protectionofcircuitsagainst
shortcircuitcurrents
• Protectionofcircuitsagainst
overloadcurrents
• Isolation
Technical data according to
IEC 60947-2:• Voltagerating(Ue):400VAC
• Impulsevoltage(Uimp):6kV
• Insulationvoltage(Ui):500VAC
• Breakingcapacity:
Rating (A) Type VoltageBreaking
capacity Icn (kA)
6-63 1P 230V 32P,3P,4P 400V 3
Generals technical data:• Fastclosing:allowsthehigh
inrushcurrentsofsomeloadsto
bebetterheld.
• Isolationwithpositivebreak
indication:openingisindicated
byagreenstriponthedevice
operatinghandle.Thisindicator
showsopeningcontactsofallthe
poles.
• Numberofcycles(O-C):20000
• Environmenttropicalisation:
treatment2(relativehumidity:
95%at55°C)accordingto
IEC60068-1
• Connection:tunnelterminalsfor
thefollowingcables:
•16mm2flexibleor25mm2rigit
upto25Aratings
•25mm2flexibleor35mm2rigit
for32to40Aratings
Type 1P 2P 3P 4PWeight(g) 120 240 360 480
3kA Z-Folded Leaflet Rev1.indd 2 2012/02/24 11:15:45 AM