5
Intra-frequency measurements Reporting event 1A: A Primary CPICH enters the reporting range Reporting event 1B: A primary CPICH leaves the reporting range Reporting event 1C: A non-active primary CPICH becomes better than an active primary Reporting event 1D: Change of best cell Reporting event 1E: A Primary CPICH becomes better than an absolute threshold Reporting event 1F: A Primary CPICH becomes worse than an absolute threshold Intra-fr Reporting event 1G: Change of best cell (TDD) Reporting event 1H: Timeslot ISCP below a certain threshold (TDD) Reporting event 1I: Timeslot ISCP above a certain threshold (TDD) Event 2a: Change of Best Frequency. Event 2b: The estimated quality of the currently used frequency is below a certain th Event 2c: The estimated quality of a non-used frequency is above a certain threshold. Event 2d: The estimated quality of the currently used frequency is below a certain th Event 2e: The estimated quality of a non-used frequency is below a certain threshold. Event 2f: The estimated quality of the currently used frequency is above a certain th Event 3a: The estimated quality of the currently used UTRAN frequency is below a cert Event 3b: The estimated quality of other system is below a certain threshold Event 3c: The estimated quality of other system is above a certain threshold Event 3d: Change of best cell in other system Reporting event 6A: The UE Tx power becomes larger than an absolute threshold Reporting event 6B: The UE Tx power becomes less than an absolute threshold Reporting event 6C: The UE Tx power reaches its minimum value Reporting event 6D: The UE Tx power reaches its maximum value Reporting event 6E: The UE RSSI reaches the UE's dynamic receiver range Reporting event 6F: The UE Rx-Tx time difference for a RL included in the active set Reporting event 6G: The UE Rx-Tx time difference for a RL included in the active set Reporting event 4a :Transport Channel Traffic Volume becomes larger than an absolut Reporting event 4b: Transport Channel Traffic Volume becomes smaller than an absolu Reporting event 5a: A predefined number of bad CRCs is exceeded

Upload: julio-huayhuameza

Post on 09-Dec-2015

212 views

Category:

Documents


2 download

DESCRIPTION

event

TRANSCRIPT

Page 1: 3G Event

Intra-frequency measurementsReporting event 1A: A Primary CPICH enters the reporting rangeReporting event 1B: A primary CPICH leaves the reporting rangeReporting event 1C: A non-active primary CPICH becomes better than an active primary CPICHReporting event 1D: Change of best cellReporting event 1E: A Primary CPICH becomes better than an absolute thresholdReporting event 1F: A Primary CPICH becomes worse than an absolute threshold Intra-frequency reporting events for TDDReporting event 1G: Change of best cell (TDD)Reporting event 1H: Timeslot ISCP below a certain threshold (TDD)Reporting event 1I: Timeslot ISCP above a certain threshold (TDD)Event 2a: Change of Best Frequency.Event 2b: The estimated quality of the currently used frequency is below a certain threshold and the estimated quality of a non-used frequency is above a certain threshold.Event 2c: The estimated quality of a non-used frequency is above a certain threshold.Event 2d: The estimated quality of the currently used frequency is below a certain threshold.Event 2e: The estimated quality of a non-used frequency is below a certain threshold.Event 2f: The estimated quality of the currently used frequency is above a certain threshold. Event 3a: The estimated quality of the currently used UTRAN frequency is below a certain threshold and the estimated quality of the other system is above a certain thresholdEvent 3b: The estimated quality of other system is below a certain thresholdEvent 3c: The estimated quality of other system is above a certain thresholdEvent 3d: Change of best cell in other systemReporting event 6A: The UE Tx power becomes larger than an absolute thresholdReporting event 6B: The UE Tx power becomes less than an absolute thresholdReporting event 6C: The UE Tx power reaches its minimum valueReporting event 6D: The UE Tx power reaches its maximum valueReporting event 6E: The UE RSSI reaches the UE's dynamic receiver rangeReporting event 6F: The UE Rx-Tx time difference for a RL included in the active set becomes larger than an absolute thresholdReporting event 6G: The UE Rx-Tx time difference for a RL included in the active set becomes less than an absolute thresholdReporting event 4a :Transport Channel Traffic Volume becomes larger than an absolute thresholdReporting event 4b: Transport Channel Traffic Volume becomes smaller than an absolute thresholdReporting event 5a: A predefined number of bad CRCs is exceeded

Page 2: 3G Event

Used Frequency is below a certain threshold

Page 3: 3G Event

Parameter MTN Default 1st carrier MTN Default 2nd carrier Parameter MTN Default 1st carrier

codeLoadThresholdDlSf128 100 100

compModeAdm 15 15

dlCodeAdm 85 85

eulNonServingCellUsersAdm 100 100

eulServingCellUsersAdm 32 32

eulServingCellUsersAdmTti2 4 4

hoType 1 0

hsdpaUsersAdm 64 64

individualOffset 0 0

interPwrMax 30 30

loadSharingGsmFraction 100 100

loadSharingGsmThreshold 75 75

loadSharingMargin 0 10

maxPwrMax 30 30

minPwrMax -15 -15

minPwrRl -150 -150

nInSyncInd 3 3

nOutSyncInd 10 10

operationalState 1 1

primaryCpichPower 330 330

pwrAdm 85 85

pwrOffset 10 10

qQualMin -18 -15

qRxLevMin -115 -113

rlFailureT 10 10

sHcsRat 7 7

sInterSearch 22 22

sIntraSearch 22 22

sRatSearch 4 4

sf16Adm 16 16

sf16AdmUl 32 32

sf16gAdm 16 16

sf32Adm 32 32

sf4AdmUl 4 4

sf8Adm 8 8

sf8AdmUl 0 0

sf8gAdmUl 0 0

usedFreqThresh2dEcno -12 -12

usedFreqThresh2dRscp -104 -104

Page 4: 3G Event

MTN Default 2nd carrier

Page 5: 3G Event

RNC MO - Hsdsch Value

codeThresholdPdu656 0

numHsPdschCodes 5