3D Image Quality Metrics for Porosity in Tissue Scaffolds
Craig Schroeder
Advisors:Ana Ivelisse Aviles - Statistical Eng. Div., ITL
Marcus Cicerone - ?? Div., MSEL
National Institute of Standards and Technology
August 11, 2005
![Page 2: 3D Image Quality Metrics for Porosity in Tissue Scaffolds Craig Schroeder Advisors: Ana Ivelisse Aviles - Statistical Eng. Div., ITL Marcus Cicerone -](https://reader036.vdocuments.us/reader036/viewer/2022070411/56649f3b5503460f94c5968a/html5/thumbnails/2.jpg)
Preliminaries
● Scaffold, tissue scaffold● Image (three-dimensional)● Porosity
– Volume of pore / total volume– 1 - density
![Page 3: 3D Image Quality Metrics for Porosity in Tissue Scaffolds Craig Schroeder Advisors: Ana Ivelisse Aviles - Statistical Eng. Div., ITL Marcus Cicerone -](https://reader036.vdocuments.us/reader036/viewer/2022070411/56649f3b5503460f94c5968a/html5/thumbnails/3.jpg)
Porosity Measurement
● Measure porosity– Scan in 3D scaffold
● MRI, CT scan
– Compute porosity
Image of MRI / CT equipment
![Page 4: 3D Image Quality Metrics for Porosity in Tissue Scaffolds Craig Schroeder Advisors: Ana Ivelisse Aviles - Statistical Eng. Div., ITL Marcus Cicerone -](https://reader036.vdocuments.us/reader036/viewer/2022070411/56649f3b5503460f94c5968a/html5/thumbnails/4.jpg)
Problem
● Inaccuracy in computed porosity– Scans contain noise– Noise affects computation– How accurate is the porosity?
![Page 5: 3D Image Quality Metrics for Porosity in Tissue Scaffolds Craig Schroeder Advisors: Ana Ivelisse Aviles - Statistical Eng. Div., ITL Marcus Cicerone -](https://reader036.vdocuments.us/reader036/viewer/2022070411/56649f3b5503460f94c5968a/html5/thumbnails/5.jpg)
Proposed Solution
● Develop an “Image Quality Metric”– Number computed for image– Higher quality indicates better accuracy
High Quality Low Quality
7 5 2 1
![Page 6: 3D Image Quality Metrics for Porosity in Tissue Scaffolds Craig Schroeder Advisors: Ana Ivelisse Aviles - Statistical Eng. Div., ITL Marcus Cicerone -](https://reader036.vdocuments.us/reader036/viewer/2022070411/56649f3b5503460f94c5968a/html5/thumbnails/6.jpg)
Metric Candidate One
● Find statistical relationships between– Computed porosity– Porosity after applying a filter– Actual porosity
● Estimate difference between– Computed porosity– Actual porosity
● “Image Quality Metric”
Stats
IQM
Original Noisy
Filtered
![Page 7: 3D Image Quality Metrics for Porosity in Tissue Scaffolds Craig Schroeder Advisors: Ana Ivelisse Aviles - Statistical Eng. Div., ITL Marcus Cicerone -](https://reader036.vdocuments.us/reader036/viewer/2022070411/56649f3b5503460f94c5968a/html5/thumbnails/7.jpg)
Statistical Relationships
![Page 8: 3D Image Quality Metrics for Porosity in Tissue Scaffolds Craig Schroeder Advisors: Ana Ivelisse Aviles - Statistical Eng. Div., ITL Marcus Cicerone -](https://reader036.vdocuments.us/reader036/viewer/2022070411/56649f3b5503460f94c5968a/html5/thumbnails/8.jpg)
Theory of Observed Slopes
● Clear trends in Least Squares angle● Explain trend with simple theory (Left)● Improve the theory for a better fit (Right)
![Page 9: 3D Image Quality Metrics for Porosity in Tissue Scaffolds Craig Schroeder Advisors: Ana Ivelisse Aviles - Statistical Eng. Div., ITL Marcus Cicerone -](https://reader036.vdocuments.us/reader036/viewer/2022070411/56649f3b5503460f94c5968a/html5/thumbnails/9.jpg)
Power Spectrum
● Signal processing● Amount of power broken down by frequency● Computed from Fourier transform
![Page 10: 3D Image Quality Metrics for Porosity in Tissue Scaffolds Craig Schroeder Advisors: Ana Ivelisse Aviles - Statistical Eng. Div., ITL Marcus Cicerone -](https://reader036.vdocuments.us/reader036/viewer/2022070411/56649f3b5503460f94c5968a/html5/thumbnails/10.jpg)
Metric Candidate Two
● Compute “power spectrum”● Find relationship between
– Computed porosity– Actual porosity– Power spectrum
● Use power spectrum to estimate error
Stats
IQM
Original Noisy
Power Spectrum
![Page 11: 3D Image Quality Metrics for Porosity in Tissue Scaffolds Craig Schroeder Advisors: Ana Ivelisse Aviles - Statistical Eng. Div., ITL Marcus Cicerone -](https://reader036.vdocuments.us/reader036/viewer/2022070411/56649f3b5503460f94c5968a/html5/thumbnails/11.jpg)
Noise Level vs Power Spectrum
● Need strong relationship between– Noise level (x axes)– Some aspect of the power spectrum (y axes)
![Page 12: 3D Image Quality Metrics for Porosity in Tissue Scaffolds Craig Schroeder Advisors: Ana Ivelisse Aviles - Statistical Eng. Div., ITL Marcus Cicerone -](https://reader036.vdocuments.us/reader036/viewer/2022070411/56649f3b5503460f94c5968a/html5/thumbnails/12.jpg)
Future Work
● Three weeks left!● Write this up as part of a publication● Consider permeability● Improve second metric
Image suggestsions?
![Page 13: 3D Image Quality Metrics for Porosity in Tissue Scaffolds Craig Schroeder Advisors: Ana Ivelisse Aviles - Statistical Eng. Div., ITL Marcus Cicerone -](https://reader036.vdocuments.us/reader036/viewer/2022070411/56649f3b5503460f94c5968a/html5/thumbnails/13.jpg)
Comments?
● Acknowledgments– Fredrick Phelan– Martin Chiang– NSF– NIST/ITL