3d flow measurement › ... · the apex instruments flow measurement systems are designed to...

3
XC-3D55 System The Apex Instruments flow measurement systems are designed to perform flow measurement sampling in accordance with US EPA Method 2, 2F, and 2G. A typical system comprises of the XC-3D55 console housed in a portable yet rugged injection molded case, a lightweight sample line with Type S pitot, and a three-hole 2G pitot or five-hole 2F pitot with 2” oversheath of specified length. The Apex Instruments flow measurement system has the essentials required to determine stack gas velocity and volumetric flow rates from a stationary source and is contained in a compact and rugged design. 3D FLOW MEASUREMENT

Upload: others

Post on 30-May-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

XC-3D55 System

The Apex Instruments flow measurement systems are designed to perform flow measurement sampling in accordance with US EPA Method 2, 2F, and 2G. A typical system comprises of the XC-3D55 console housed in a portable yet rugged injection molded case, a lightweight sample line with Type S pitot, and a three-hole 2G pitot or five-hole 2F pitot with 2” oversheath of specified length. The Apex Instruments flow measurement system has the essentials required to determine stack gas velocity and volumetric flow rates from a stationary source and is contained in a compact and rugged design.

3D FLOW MEASUREMENT

Flow Measurement System KitsXC-3D55 Flow Measurement Console

Method 2G and 2F Recommended Parts List

Quantity Part Number Description1 XC-3D55 3-D Flow Measurement Console

1 (for Method 2G) 2DPT2 3 Hole Prism-shaped Directional Pitot with 2 ft. Sheath

1 (for Method 2F) 3DPT2 5 Hole Prism-shaped Directional Pitot with 2 ft Sheath

1 32PTX- Probe Extension, 2” Diameter, Stainless Steel, 10 feet length

1 PF-46XT32S Port Flange with Extension, Flange Fits, 4 & 6 in. Ports

1 32M/32B-B 2 in. Bored Brass Bushing, 2 in. MNPT with 2.035 in. Bore

1 PG-32S2 in. Packing Gland, SS Body & Nut, 2 in. MNPT, PTFE ferrule included

1 PT-CAL-W2GB 2D Pitot Wind Tunnel Calibration, 60 & 90 fps

1 UINC-3D- 3-D Umbilical Cord, SpecifyLength in feet, Inclinometer Pod

1 U-PTX- 2” Dia. Pitot Sheath Extension, See Legend below for specifics

32M/32B-B

PF-46XT32S

PG-32S

32PTX-

U-PTX-(Specify Length in Feet,

See Chart on Right)

UINC-3D-(Specify Length in Feet)

OR

2DPT2 3 hole Pitot Head (for Method 2G)

3DPT2 5 hole Pitot Head (for Method 2G)

The XC-3D55 is designed for conducting flow measurement in accordance with EPA methods 2, 2F, 2G, and 2H. The console contains 2 pressure transducers with Digital Displays for measuring the Total velocity and the pitch pressure component, a bi-directional “Null” Magnehelic and inclinometer for measuring the yaw angle and a temperature display for the stack temperature. The console can be coupled with a type “S” or 3-hole prism pitot for Method 2G; or a 5-hole Pitot for Method 2F along with the inclinometer pod and integrated umbilical.

Main Power Switch

Probe Temperature Display

Velocity Pressure Display

Pitch Pressure Display

IEC Power Input Receptacle

Yaw Null Magnehelic

Yaw Angle Display

Probe Connection Quick Connects

Probe Temperature Thermocouple connection

800-882-3214 or 919-557-7300Website: www.apexinst.com / Contact: [email protected]

Flow Audit Accessories

Apex Instruments204 Technology Park Lane,

Fuquay Varina, NC 27540 USA

Flow System Recommended Audit Accessories

Digital Hand-Held Manometer 0-28 inch H2O Selectable Range English/MetricDHM-M100

Digital Display Reference Incli-nometerM5C-4Mounting BracketM5C-4-16

Squeeze Bulb PumpA-350

Calibration PumpGenerates Pressure and Vacuum, NIST 0” to 5” H2OA-396A

1/8ID X 1/4OD Tubing,Polyurethane, Sold by the FootTPOE-4/2NA

Probe Clamp, 2 halvesCLP-2P

Female Quick Connect with CapQC-F4-SS

Male Quick ConnectQC-M4-SS

Probe Leak Check PlugsRed 40025K22Blue 40025K23

Thermocouple SimulatorM5C-VA710