3370 high power dc electronic load - sondas de tensión y ... catalogprodig.pdf60v/1000a,5000w...

2
60V/1000A5000W 3370 High Power DC Electronic Load Description Compact size (483Wx177Hx635Dmm) possess 5KW/1000A Electronic Load capability 5 digit V/A/W Meter High-speed measurement and communication transmission Large LCD Displaysetting values can be adjusted by rotary knob or push button Voltage Current and Watt value can be displayed simultaneously OCP OPP test function Power ON status can be set CC, CR, CV, CP, Dynamic and Short operation mode SHORT time setting Protections against V,I,W, and °C Voltage meter display the polarity positive (”+”or negativeis selectable Optional Interface: GPIBRS232USBLAN Voltage/Current source SMPS transient response CV/Current limit testing and battery emulation Battery charger Battery discharge R&D Quality Control ATE system Production testing Application 3370 has its own control and display panel, CC/CR/CV/CP/Dynamic modes, 150 sets Store/Recall memory which provides load set-up more efficiently, also can be remote controlled via GPIBRS232USB and LAN interface. SHORT time setting and SHORT_VH, SHORT_VL setting function, also can measure Short Voltage and Current Dynamic can be simulated under CC, CP mode. The current Rise/Fall slew rate can be adjusted individually and there is an external signal input for a Arbitrary Waveform to simulate load current. Single key for OCP OPP test function will be more efficiency and accuracy on OCPOPP testing. Programmable Load ON/OFF voltage, GO/NG meter check, Voltage meter display ” + “ or “ – “ is selectable and 150 sets Store/Recall larger memory is much advance feature for each different application. 150 sets test parameter and status storage function, user can recall the storage memory real time in accordance with the auto sequence requirement. Feature rear

Upload: others

Post on 12-May-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

60V/1000A,5000W3370 High Power DC Electronic Load

Description

Compact size (483Wx177Hx635Dmm) possess 5KW/1000A Electronic Load capability

5 digit V/A/W Meter

High-speed measurement and communication transmission

Large LCD Display、setting values can be adjusted by rotary knob or push button

Voltage 、Current and Watt value can be displayed simultaneously

OCP 、 OPP test function

Power ON status can be set

CC, CR, CV, CP, Dynamic and Short operation mode

SHORT time setting

Protections against V,I,W, and °C

Voltage meter display the polarity positive (”+”)

or negative(”-”)is selectable

Optional Interface: GPIB、RS232、USB、LAN

Voltage/Current source

SMPS transient response

CV/Current limit testing and battery emulation

Battery charger

Battery discharge

R&D Quality Control

ATE system

Production testing

Application

3370 has its own control and display panel, CC/CR/CV/CP/Dynamic modes, 150 sets Store/Recall memory which provides load set-up more efficiently, also can be remote controlled via GPIB、RS232、USB and LAN interface.

SHORT time setting and SHORT_VH, SHORT_VL setting function, also can measure Short Voltage and Current

Dynamic can be simulated under CC, CP mode. The current Rise/Fall slew rate can be adjusted individually and there is an external signal input for a Arbitrary Waveform to simulate load current.

Single key for OCP 、OPP test function will be more efficiency and accuracy on OCP、OPP testing.

Programmable Load ON/OFF voltage, GO/NG meter check, Voltage meter display ” + “ or “ – “ is selectable and 150 sets Store/Recall larger memory is much advance feature for each different application.

150 sets test parameter and status storage function, user can recall the storage memory real time in accordance with the auto sequence requirement.

Feature

rear

Specifications

Data Subject Change without Notice

Range *2

ResolutionAccuracyRangeResolutionAccuracyRangeResolutionAccuracyRangeResolutionAccuracy

Thigh & TlowResolutionAccuracySlew rateResolutionMin. Rise TimeRange*2

ResolutionAccuracy

Range (5 Digital)ResolutionAccuracyRange (5 Digital)ResolutionAccuracyRange (5 Digital)ResolutionAccuracy*3

CurrentTemperature CoefficientPower ConsumptionOperating Temperature *4

Dimension(HxWxD)WeightSafety & EMC

Power *1

CurrentVoltageMin.Operation VoltageCC Mode

CR Mode

CV Mode

CP Mode

Dynamic ModeTiming

Current

MeasurementVoltage Read Back

Current Read Back

Power Read Back

GeneralShort Circuit

0-60V

0.1% + 0.1% F.S.

0.2% + 0.2% F.S.

0.05% +0.05% F.S.

0.5% + 0.5% F.S.

0.050~9.999 / 99.99 / 999.9 / 9999mS0.001 / 0.01 / 0.1 / 1mS

1uS/10uS/100uS/1mS + 50ppm

0.025% + 0.025% F.S.

0.1% + 0.1% F.S.

0.125% + 0.125% F.S.

1000A100ppm/℃ (typical)

600Wmax0~40℃

177 x 440 x 628.5 mm/6.9x17.3x24.7 inch45 kg / 99.2 lbs

CE

5000W0-100A

0.1V @ 100A0-100A

1.667mA

0.001-0.06ohm16bits

6V0.1mV

500W8.334mW

66.4mA~4.15A/uS16.6mA/uS

24uS (typical)0~100A1.667mA

0.1% + 0.1% F.S.

0~6V16bits

0~100A16bits

0~600W0.01W

5000W0-1000A

0.7V @ 1000A0-1000A16.67mA

0.06-3600ohm16bits

60V1mV

5000W83.34mW

664mA~41.5A/uS166mA/uS

24uS (typical)100~1000A

16.67mA0.1% + 0.1% F.S.

6~60V16bits

100~1000A16bits

5000W0.1W

3370 Optional Interface: Optional Cable:

Order Information

60V,1000A,5000W 1. GPIB Card 2. RS232 Card 3. USB Card 4. LAN Card1000A load connection cable ( 1M / 2M / 3M / 4M / 5M )

Ambient Temperature

100%

85%

Power Rating

5。C 15。C 30。C 40。C

。C

Voltage

60V

5V

0.7V

5000WPower Curve

83.33A 1000ACurrent

Note *1 : The power rating specification at ambient temperature=30℃ See the diagram below for power rating.

Note *2 : The range is automatically or forcing to range II only in CC mode

Note *3 : Power F.S. = Vrange F.S. x Irange F.S.Note *4 : Operating temperature range is 0~40℃, all specifications

apply for 25℃±5℃, except as noted Input AC Power:115V/230Vac ±10%,50/60Hz Cooling : Advanced Fan Cooled

3370Model