DEVELOPMENT APPLICATION
D-2018/636
APPLICANT: Mr M Pettit
PROPOSAL: Dwelling addition & alterations
LOCATION: 31 Tilanbi Street, HOWRAH
RELEVANT PLANNING SCHEME: Clarence Interim Planning
Scheme 2015
ADVERTISING EXPIRY DATE: .14 November 2018
In addition to the Application Form(s), Certificate of Title(s) and any associated
consent documents the following information is available on request:
• Nil
The relevant plans and documents can be inspected at the Council offices, 38 Bligh Street, Rosny Park,
during normal office hours until 14 November 2018.
Any person may make representations about the application to the General Manager, by writing to PO
Box 96, Rosny Park, 7018 or by electronic mail to [email protected]. Representations must be
received by Council on or before 14 November 2018.
To enable Council to contact you if necessary, would you please also include a day time contact
number in any correspondence you may forward.
Any personal information submitted is covered by Council’s privacy policy, available at
www.ccc.tas.gov.au or at the Council offices.
Proposed Extensionfor
M. Dunkleyat 31 Tilanbi Street
Howrah
Job No. 80806
NOTES TO PLANS: To be read in conjunction with plans and specifications
1. Figured dimensions to be used. Do not scale drawings.
2. It is recommended that all levels, set outs and dimensions be verified by a registered Surveyor.
3. All materials to be in accordance with the relevant SAA Code, BCA and/or Manufacturers specifications.
4. All work to be carried out in accordance with relevant SAA Code, Manufacturers specifications and BCA
5. Pettit Designs hereby guarantee that the plans and specifications will meet requirements of the Local
Authority.
Although every care is taken no responsibility is accepted for misinterpretation error or omission. It is
the Contractors responsibility at all times to verify dimensions and levels etc. prior to and during
constructions.
6. These drawings to be read in conjunction with Engineers reports and associated details thereof.
7. All plumbing and drainage to Local Authority specifications and BCA where applicable.
CONTENTSPAGE DRAWING SCALE
1. Bushfire Hazard Plan 1:1000
2. Location plan 1:500
3. Site plan 1:200
4. Existing elevations 1:100
5. Existing elevations 1:100
6. Existing lower floor plan 1:100
7. Existing upper floor plan 1:100
8. Proposed elevations 1:100
9. Proposed elevations 1:100
10. Proposed upper floor plan 1:100
11. Floor framing plan 1:100
12. Roof framing plan 1:100
13. Roof plan 1:100
14. Section A 1:50
15. Drainage details
16. Window flashing details (cladding) 1:5
17. Window flashing dertails (brickwork) 1:5
18. Window flashing detils (general)
19. Specifications to NCC v2
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092U
DATE: October 2018
A.B.N. 87 667 918 807
Phone: (03) 62730986
Mobile: 0406 481283
Email: [email protected]
Licence No. CC5092U
(Building Designer B Domestic)
BBBBBBBBBBBBBBBBBBBBBBBBBBBBB
pettit designs Matthew Pettit
Accredited Building
Practitioner
The following attachments must be read by the builder in conjunction with
the plans and form part of the documentation for the project.
* Form 55 B Structural engineering by Certifying Project Engineer
* Title B including Folio Text, Folio Plan & Council Certificate
* Harditex Base Sheet Specification & Installation Guide
* Safety in Construction
* Window/door installation manual
* James Hardies Wet Area Construction Application Guide
EXISTING LOWER FLOOR AREA 138m²
EXISTING UPPER FLOOR AREA 134m²
PROPOSED ADDITIONAL FLOOR AREA 23.5m²
EXISTING DECK/PATIO AREAS 67.54m²
TOTAL 363m²
TITLE REFERENCE: volume B 55656
folio B 6
REGISTERED TITLE NUMBER: 55656
PRIOR CT: 2037/57
SITE AREA 668.95m²
SITE COVER 249m² = 37%
OPEN SPACE 157m²
CAR PARKING 2
COUNCIL CLARENCE CITY
PLANNING ZONE 10.0 GENERAL RESIDENTIAL
PLANNING OVERLAY TO BLOCK N/A
PLANNING REQUIREMENTS DA REQUIRED
BUSHFIRE ATTACK LEVEL (BAL) LOW
ALPINE ZONE CLASSIFICATION N/A
CLIMATE ZONE 7
CORROSION CLASSIFICATION (STRUCTURAL) MODERATE
CORROSION CLASSIFICATION (ROOFING) LOW
WIND SPEED CLASSIFICATION N2
SOIL CLASSIFICATION H
Received 22/10/2018
Scale 1:1000
BUSH FIRE HAZARD PLAN1/19
N
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092U
DATE: October 2018
BUSH FIRE ATTACK LEVEL DETERMINATION:
NO THREAT PERCEIVED AS NO UNMANAGED
BUSH OR GRASSLAND WITHIN 100m RADIUS
OF PROPERTY AT
31 TILANBI STREET, HOWRAH
R100m
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
Received 22/10/2018
Scale: 1:250
LOCATION PLAN1/19
N
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092U
DATE: October 2018
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
No.31
No.29
No.33
3766
TI
LA
NB
I S
TR
EE
T
PH
EO
NI
XS
TR
EE
T
SO
UT
H A
RM
R
OA
D
(N
OR
TH
B
OU
ND
)
SO
UT
H A
RM
R
OA
D
(S
OU
TH
B
OU
ND
)
Received 22/10/2018
Scale: 1:200
SITE PLAN3/19
IMPORTANT: Use written dimensions only. Confirm
all dimensions on site before
commencing any work.
Ensure that this drawing and any
accompanying details and /or
specifications have been stamped
"approved" by the relevant local
authorities, and that any conditions of
approval are incorporated into the
works.
All materials and workmanship shall
conform with relevant standard,
Building Code of Australia (BCA)
requirements and product specification
and any addendum to that
specification.
This drawing remains the property of
the designer and its use is restricted to
the licence granted to the client for the
project as specified.
IT IS THE BUILDERS RESPONSIBILITY
TO VERIFY THE LOCATION OF ALL
UNDERGROUND SERVICES,
INCLUDING BUT NOT LIMITED TO;
GAS, WATER, SEWER, STORM WATER,
ELECTRICITY, TELECOMMUNICATIONS.
OPEN SPACE CALCULATIONS
scale 1:500
ALL LEVELS TO BE VERIFIED BY
BUILDER PRIOR TO
COMMENCEMENT OF WORK
N
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092UDATE: October 2018
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
3657
6mm
232°
52'50"
18288m
m
142°5
2'50"
3657
6mm
232°
52'50"
18288m
m
142°5
2'50"
157m²
TI
LA
NB
I S
TR
EE
T
EXISTING
RESIDENCE
EXISTING
VERANDAH
EXISTING
VERANDAH
2100
9110
EXISTING LOWER FLOOR AREA 138m²
EXISTING UPPER FLOOR AREA 134m²
PROPOSED ADDITIONAL FLOOR AREA 23.5m²
EXISTING DECK/PATIO AREAS 67.54m²
TOTAL 363m²
TITLE REFERENCE: volume G 55656
folio G 6
REGISTERED TITLE NUMBER: 55656
PRIOR CT: 2037/57
SITE AREA 668.95m²
SITE COVER 249m² = 37%
OPEN SPACE 157m²
CAR PARKING 2
COUNCIL CLARENCE CITY
PLANNING ZONE 10.0 GENERAL RESIDENTIAL
PLANNING OVERLAY TO BLOCK N/A
PLANNING REQUIREMENTS DA REQUIRED
BUSHFIRE ATTACK LEVEL (BAL) LOW
ALPINE ZONE CLASSIFICATION N/A
CLIMATE ZONE 7
CORROSION CLASSIFICATION (STRUCTURAL) MODERATE
CORROSION CLASSIFICATION (ROOFING) LOW
WIND SPEED CLASSIFICATION N2
SOIL CLASSIFICATION H
ADDITION OVER EXISTING UPPER FLOOR PATIO
Received 22/10/2018
Scale 1:100
ELEVATIONS4/19
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092U
DATE: October 2018
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
SOUTH WEST ELEVATION
SOUTH EAST ELEVATION
GROUND LEVEL
EXISTING LOWER FLOOR LEVEL
EXISTING LOWER CEILING LEVEL
EXISTING LOWER FLOOR LEVEL
EXISTING LOWER CEILING LEVEL
GROUND LEVEL
GROUND LEVEL
EXISTING FLOOR LEVEL
EXISTING CEILING LEVEL
EXISTING FLOOR LEVEL
EXISTING CEILING LEVEL
WINDOW TO BE RESERVED AND REUSED
Received 22/10/2018
Scale: 1:100
ELEVATIONS5/19
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092U
DATE: October 2018
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901NORTH WEST ELEVATION
EXISTING FLOOR LEVEL
EXISTING CEILING LEVEL
GROUND LEVEL
2440
EXISTING FLOOR LEVEL
EXISTING CEILING LEVEL
GROUND LEVEL
EXISTING LOWER FLOOR LEVEL
EXISTING LOWER CEILING LEVEL
2440
2330
NORTH EAST ELEVATION
670
3352
Received 22/10/2018
shr
Scale: 1:100
LOWER FLOOR PLAN6/19
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092U
DATE: October 2018
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
EXISTING
rumpus
bath
sewing garage
cellar
boat
UP
SGD
Received 22/10/2018
shr
FR
FR
Scale: 1:100
UPPER FLOOR PLAN7/19
EXISTING
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092UDATE: October 2018
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
UP
UP
UP
kitchen
dining/living
passage
bath
wc
laundry
bed
bed
bed
patio
ramp
pergola
UP
110
step up
110 step up
alfresco
TRIM EDGE OF DECK 10mm BELOW FACE OF BRICKWORK
GRIND BACK ANY EXPOSED REINFORCING 20mm INTO FACE
OF CONCRETE SLAB, TREAT WITH RUST PROHIBITER, SEAL
AND COVER WITH GROUT
REMOVE WINDOW, TIMBER FRAME AND OUTER BRICKWORK.
CORNER STUD TO REMAIN SUPPORTING ROOF AND SIDE
WINDOW
REMOVE BRICKWORK
STUD WALL TO REMAIN
REMOVE WINDOW, TIMBER FRAME
AND OUTER BRICKWORK.
CORNER STUD TO REMAIN
SUPPORTING ROOF AND SIDE
WINDOW
REMOVE ALL HANDRAIL AND BALUSTRADE
WHERE REQUIRED REPLACE WITH NEW HANDRAIL TO
1000 HIGH FROM PATIO DECK LEVEL OR 850 FROM
STAIR NOSING
REOMOVE POST
Received 22/10/2018
Scale 1:100
ELEVATIONS8/19
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092U
DATE: October 2018
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
SOUTH WEST ELEVATION
SOUTH EAST ELEVATION
2440
EXISTING FLOOR LEVEL
EXISTING CEILING LEVEL
GROUND LEVEL
EXISTING LOWER FLOOR LEVEL
EXISTING LOWER CEILING LEVEL
EXISTING LOWER FLOOR LEVEL
EXISTING LOWER CEILING LEVEL
GROUND LEVEL
GROUND LEVEL
EXISTING/FINISHED FLOOR LEVEL
EXISTING/FINISHED CEILING LEVEL
ROOF SHEET TO MATCH EXISTING
2° ROOF PITCH
JAMES HARDIES HARDITEX FIXED
AS PER MANUFACTURES
SPECIFICATION.
TEXTURE COAT FINISH
BARGE BOARD, FACIA & GUTTER TO
MATCH EXISTING.
REPLACE AS REQUIRED WITH
COLORBOND STEEL OPTION
DECK EDGE WHERE TRIMMED TO
BE FACED WITH SLICED BRICK
~10mm THICK
HARDITEX WALL SHEET FIXED AS PER MANUFACTURERS
SPECIFICATION OVER 20 VERTICAL BATTEN
BATTEN FIXED TO STUDS OVER WALL WRAP
BOUNDARY
BOUNDARY B
UILDING
ENVELOPE
5138
RELOCATED RESERVED WINDOW
Received 22/10/2018
Scale: 1:100
ELEVATIONS9/19
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092U
DATE: October 2018
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
NORTH WEST ELEVATION
EXISTING FLOOR LEVEL
EXISTING CEILING LEVEL
GROUND LEVEL
2440
EXISTING FLOOR LEVEL
EXISTING CEILING LEVEL
GROUND LEVEL
EXISTING LOWER FLOOR LEVEL
EXISTING LOWER CEILING LEVEL
2440
2330
NORTH EAST ELEVATION
670
3442
HARDIETEX BASE SHEET
RENDER FINISH
INSTALLED TO MANUFACTUERS SPECIFICATION
Received 22/10/2018
shr
FR
FR
Scale: 1:100
UPPER FLOOR PLAN10/19
PROPOSED
FIRE SAFETY
Denotes position of
wired�in smoke
detectors. Install if
not already installed.
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092UDATE: October 2018
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
dining/livingbed
patio
UP
UP
bed
passage
bed
kitchen
bathwc
laundry
UP
EXISTING LINTEL TO BE BOXED
FORMING BULKHEAD
89x89x3.5 SHS CFW 200x90x8pl
FIXED TO SLAB USING 2/M12
CHEMICAL ANCHORS
3070
90
1637
90
4733 3437
9050
110
90
237450
237490
66
5058
14 14
90
A
14
WALL TO BE CONSTRUCTED OF:
• 10 PLASTERBOARD
• 90 MGP10 STUD @ 450℄
• 50 CAVITY
• 90 MGP10 STUD @ 450℄
• VAPOR PERMEABLE MEMBRANE
• 20 VERTICAL BATTEN @ STUD ℄
• HARDITEX SHEET, TEXTURE COAT FINISH
23.23
23.23
23.33
13.2
8
HARDWOOD STRIP FLOORING
OVER BATTENS TO MATCH
EXISTING
Received 22/10/2018
Scale: 1:100
FLOOR FRAMING PLAN11/19
STAIRS & BALUSTRADESSTAIRS min clear width of 820mm
min going 240mm
max going 355mm
min rise 115mm
max rise 190mm
Provide solid/partly solid risers to
125mm from u/s of above tread.
STRINGERS
240x45 F5 (internal)
240x45 F5 (external)
TREADS
45 thick F5 (int & ext)
BALUSTRADES
1000mm high to owners spec.
125mm max aperture.
Wire balustrade to comply with Clause
3.9.2.3 (f) and Table 3.9.2.1 and Table
3.9.2.2.
All treads to be provided with a
slip4resistant finish or non4skid strip in
accordance with 3.9.1.3 (g).
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092UDATE: October 2018
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
LEGENDC1. COLUMN 89x89x3.5 SHS CFW 90x200x10pl BASEPLATE FIXED TO SLAB USING 2/M12 CHEMICAL ANCHORS, 8pl CAPPING CFW
C2. COLUMN 100x50x2.5 SHS CFW 90x200x10pl BASEPLATE FIXED TO SLAB USING 2/M12 CHEMICAL ANCHORS, 8pl CAPPING CFW
B1. TRIMMER 91x45 HYSPAN LVL H2 OR TRP FIXED TO MASONARY USING M12 MECHANICAL FIXINGS @ 600 ℄
B2. TRIMMER 2/119x45 HYSPAN LVL H2 OR TRP FIXED TO SLAB USING M12 MECHANICAL ANCHORS @ 600 ℄
B3. TRIMMER 2/1064119x45 HYSPAN LVL H2 OR TRP FIXED TO SLAB USING M12 MECHANICAL ANCHORS @ 600 ℄
J1. JOIST 119491x35 HYSPAN LVL H2 OR TRP
F. FLOORING 108x19 HARDWOOD FLOORING
NOTE: ALL TIMBERS TO BE SEPARATED FROM CONCRETE WITH 500µm POLYTHENE DPC.
CONCRETE SLAB TO BE WATERPROOFED WITH PAINTABLE SEALER.
NOTE: INSTALLATION OF DAMP4PROOF COURSE MUST BE
IN ACCORDANCE WITH BCA V2 3.3.4.5
EXTRACT FROM BCA
3.3.4.5 ...
(c) The height of a DPC, or flashing serving as a DPC, (see Figure 3.3.4.1 BCA V2) must be
not less than 4
(i) 150mm above the adjacent ground level; or
(ii) 75mm above the finished surface level of adjacent paved, concreted or landscaped
areas that slope away from the wall (see Figure 3.3.41.1 BCA V2); or
(iii) 50mm above finished paved, concreted or landscaped areas complying with
3.1.2.3(b)(iii) BCA V2 and protected from direct effects of the weather by a carport,
verandah or the like.
...
C1
C1
C1 C1 C1
C1
B1
FJ1
B3
B2
Received 22/10/2018
Scale: 1:100
ROOF FRAMING PLAN12/19
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092U
DATE: October 2018
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
LEGENDR1. RAFTER EXISTING 140x45 F17 @ 900 ℄
R2. RAFTER 120x45 F17 @ 900℄ FIXED TO SIDE OF (R1) TO POINT OF SUPPORT FOR (R1)
C1. COLUMN 89x89x3.5 SHS CFW 90x200x10pl BASEPLATE FIXED TO SLAB USING 2/M12
CHEMICAL ANCHORS, 8pl CAPPING CFW
C2. COLUMN 100x50x2.5 SHS CFW 90x200x10pl BASEPLATE FIXED TO SLAB USING 2/M12
CHEMICAL ANCHORS, 8pl CAPPING CFW
H1. COUNTER 150PFC CFW (C1)
H2. HANGER 150PFC WITH 8pl CLEATES @ RAFTER ℄
L1. LINTEL 89x89x3.5 SHS CFW (C1) & (C2) TO FORM PORTAL FRAME
C1
C1
C2
C1
C1
C1
L1
L1L1
R1
R2
H1
H2
L1
CROSS TENSIONED GALVANISED
30x0.8 PERFORATED STRAP
CROSS TENSIONED GALVANISED
30x0.8 PERFORATED STRAP
Received 22/10/2018
ROOF WATER DRAINAGERainfall intensity � 155mm/hour (1 in 100 years)
Roof area � 211.61m²
Number of downpipes � 3
Size of downpipe � 90mm
Size of gutter � 115mm D gutter
CALCULATIONS
Downpipe Size Catchment
1 Ø90 92.36m² [EXISTING]
2 Ø90 23.21m² [EXISTING]
3 Ø90 90.35m²
NOTE: All eaves gutters to have a fall of 1:500 to
downpipe.
Scale: 1:100
ROOF PLAN13/19
DRAFTED BY: MATTHEW RICHARD PETTITACCREDITATION No. CC5092UDATE: October 2018
PROPOSED EXTENSION31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
FALL
DP1
DP2
FALL
FALL
92.36m²
92.36m²
EXISTING
PERGOLA
DP3
EXISTINGVERANDAH
SW�DN100CONNECT NEW
STORMWATER LINE FROM
(DP3) INTO EXISTING
STORMWATER CONNECTION
EXISTING ROOF
Received 22/10/2018
Scale: 1:50
SECTION A14/19
FINISHED CEILING LEVEL
FINISHED FLOOR LEVEL
GROUND LEVEL
TIE DOWNS (uplift forces)Rafters/trusses to top plate ! 30x0.8 looped strap with 6/30x2.8 nails
each end or 2 framing anchors.
Roof battens to rafters/trusses 1/75mm No.14 Type 17 Screw.
Studs to top/bottom plate refer to structural details sheet.
Bottom plate to slab/floor joists refer to structural details sheet.
Floor joist to bearer refer to structural details sheet.
Bearer to column refer to structural details sheet.
FRAMING MGP10(2400mm high)Studs 90x35 at 450mm crs.
Jamb studs 2/90x35 to max 2400mm opening
(sheet roof) 3/30x35 to max 3600mm opening
Jamb studs 90x35 to max 1500mm opening
(tile roof) 2/90x45 to max 2400mm opening
3/90x45 to max 3600mm opening
Bottom plate 90x35 ! concrete slab
90x35 ! timber floor where studs
positioned over or within 50mm of
floor joists. Refer AS1684.4 for
other than above.
Top plate 2/90x35 where trusses/rafters
over or within 100mm of same.
Refer AS1684.4 for other than
above.
Nogging 90x35 at 1350 crs. max
ARTICULATION JOINTSARTICULATE MASONRY GENERALLY AT 6000 ℄ (max), IN ACCORDANCE
WITH BCA Vol 2 3.3.1.8
PROVIDE ARTICULATION AT JUNCTION OF TIMBER AND CONCRETE
FLOORS & WALLS.
WALL & CEILING LININGS10mm plasterboard on furring channel to ceilings except where
otherwise noted.
10mm plasterboard to wall areas except where otherwise noted.
WET AREA FINISHES TO AS3740Villaboard or wet area plasterboard to all walls and ceilings.
Ceramic tiles or similar to 1800mm above shower base.
Ceramic tiles or similar to 150mm above vanity/laundry basins.
Ceramic tiles or similar to 300mm above kitchen benches.
Ceramic tiles or similar to all floors with approved cement sheet
underlay to timber floors fixed as per manufacturers instructions.
Provide approved waterproofing as required in strict accordance with
Part 3.8.1 of BCA (REF: WET AREA SPECIFICATIONS SHEET)
FIRE SAFETYDenotes position of
wired!in smoke detectors
(refer floor plan).
All smoke detectors to be
interconnected on same circuit.
ENERGY EFFICIENCYProvide 55mm R1.3 Anticon roof blanket under roofing
Provide R3.0 high density fibreglass batts or similar to
ceiling areas.
Provide (VPM) vapor permeable membrane to all external
walls fixed to external face of wall frame. Afix 20 thick
vertical batten to stud over top of VPM
Provide R2.0 high density fibreglass batts or similar
between studs and all external walls.
Provide anti infiltration seal to all edges of external doors
and windows.
Provide 75 Extruded Polystyrene (XPS) on 12 thick
battens over existing slab. Slab to be watersealed.
GLAZINGAll Glazing to AS1288, AS2047 and parts 3.6.5,
3.6.6 and 3.6.9 of BCA. Certification to be provided
to Local Authority.
It is the responsibility of the glazing manufacturer
to determine compliance with the above.
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092UDATE: October 2018
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
B1 B2
STRUCTURAL STEELCorrosion protection to be provided as per Table 3.4.4.2 of BCA
[ MODERATE > 1km FROM BREAKING SURF OR > 100m FROM SALT WATER NOT SUBJECT
TO BREAKING SURF OR NON �HEAVY INDUSTRIAL AREAS ]
ALL STRUCTURAL STEEL TO BE HOT DIP GALVANISED AND ALL CUT SURFACES OR
WELDED JOINTS TO BE TREATED WITH MIN 2 COATS ALKYD PRIMER
J1
19 HARDWOOD
STRIP FLOORING
EXISTING
CONCRETE
PATIO SLAB
75 EXTRUDED
POLYSTYRENE ON
12 BATTEN
RAFTER (R2)RAFTER (R1)
EXISTING FLOOR
EXISTING FLOOR
WINDOW REMOVED
AND RELOCATED
OPENING FILLED AND
MADE GOOD
RELCATED
WINDOW
LINTEL (L1)
FASCIA & GUTTER TO MATCH EXISTING
A
10
Received 22/10/2018
DRAINAGE DETAILS15/19
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092U
DATE: October 2018
450 trench
arch
20mm gravel
Trench geotextile lined
600mm
100mm topsoil
300mm
MIN. 9 x S.D.
TRENCH MESHCONTINUOUS
LOCALLY
DEEPENED
FOOTING
SLEEVE OR LAGGING
PIPE
SERVICE PIPESPIPES THROUGH FOOTINGS AND SLAB BEAMS SHOULD BE LAGGED.SLAB BEAM DEPTHS AND FOOTING DEPTHS SHOULD ALSO BEINCREASED AS INDICATED BELOW.
SLEEVE DIAMETER (S.D) TOPROVIDE MIN 30mm RADIALCLEARANCE TO SERVICE PIPE.
NOTE: DEPTH OF THICKENING = S.D.
PIPE THROUGH FOOTING DETAILS INCLASS M, H1, H2, E soils (Refer details right)
AG DRAIN
ABSORPTION TRENCH(Roofwater)
SILT PIT
NOTES:
* All pipework = eg DN100 etc denotes Ø100 etc
* Location of existing sewer and stormwater lines INDICATIVE only.
* All new sewer lines suspended under new floor
* Sewer falls min 1:60min. cover
= 300mm under soil
= 75mm under paving (driveway=light)
= 100mm under concrete (driveway = heavy)
= 50mm under paving (non=trafficable)
= under building = 25mm cover to u/s slab
* Stormwater falls min 1:100min. cover
= 100mm under soil
= 50mm under paving
= driveway = 75mm under concrete
= 100mm under paving
Trench construction in M,H1,H2 and E soil classifications as per AS 3500
For soil classifications H1,H2 and E
Provide 20mm closed cell polyethylene lagging around pipes for Class H1
Provide 40mm " " " " " " " " Class H2 & E
Provide articulated joints,expansion joints, swivel joints etc to manufacturers directions
Penetrations through the middle third only of the footing
* Ag drains falls min 1:300
* Provide IO"s to SL at approx. 8m crs
To be used where notconnected to reticulated
stormwater system
Received 22/10/2018
CLADDING
EXTERIOR WALL SHEETING
(OPTIONAL)
RBM
6mm GAP DO NOT
CAULK, EXTEND
25mm
"Z" FLASHING, EXTENDING 25mm
EACH SIDE. 50mm VERTICAL LEG
RECOMMENDED.
HARDITRIM OR SIMILAR
WINDOW FRAME.
FLASH PER WINDOW
MANUFACTURER
10mm PLASTER
BOARD LINING
R2.5
INSULATION
WINDOW HEAD
RBM
R2.5
INSULATION
EXTERIOR WALL
SHEATHING
FASTENERS
FASTENERS
SEE FASTENING SCHEDULE
SEALANT
SEALANT
RBM
R2.5 INSULATION
FASTENERS
WINDOW FRAME
HARDITRIM OR SIMILAR
3mm GAP BETWEEN
SIDING AND TRIM, AND
SEALANT AT GAP
200mm DPC fLASHING
BETWEEN WEATHER
BARRIER AND FRAME
6mm HARDIFLEX
CEMENT SHEET
10mm PLASTER
BOARD LINING
10mm PLASTER
BOARD LINING
HARDITRIM OR SIMILAR
3mm GAP BETWEEN
SIDING AND TRIM, AND
SEALANT AT GAP
EXTERIOR WALL
SHEETING (OPTIONAL)
CLADDING
ROOF OVERHANG, SEE PLAN
RBM
200mm DPC
FLASHING BETWEEN
WEATHER BARRIER
AND FRAME
R2.5 INSULATION
3mm GAP BETWEEN SIDING AND
TRIM, AND SEALANT AT GAP
FASTENERS
WINDOW FRAME.
FLASH PER
WINDOW
MANUFACTURER
FLASHING WITH
END DAMS
END DAM BEYOND
SEALANT
3mm GAP BETWEEN
SIDING AND TRIM, AND
SEALANT AT GAP
RBM
FASTENERSHARDITRIM OR SIMILAR
EXTERIOR WALL
SHEETING (OPTIONAL)
10mm PLASTER
BOARD LINING
CLADDING
HARDITRIM OR SIMILAR
90x35 MGP10
FRAME
10mm PLASTER
BOARD LINING
R2.5 INSULATION
EXTERIOR WALL
SHEETING (OPTIONAL)
CLADDING
Scale: 1:5
WINDOW FLASHING DETAILS16/19
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092U
DATE: October 2018
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
WEATHERBOARD
DETAILS FOR
WEATHERBOARD AND
SIMILAR LIGHT WEIGHT
CLADDINGS
Received 22/10/2018
flashing required when’A’ < 3 x ’B’
opening
A
B
weepholemax 1200 crs
flashing
openingweepholemax 1200 crs
cut standardbrick sill
45° sill brick
sill nosing
sill nosing
flashing
flashing
frame frame
plasterboard plasterboard
standardbrick leaf
weepholes at1200 crs max
standardbrick leaf
weepholes at1200 crs max
WINDOW FLASHING DETAILS
FLASHING
3mm GAP BETWEEN
SIDING AND TRIM, AND
SEALANT AT GAP
RBM
90x35 MGP10
FRAME
R2.5 INSULATION
WALL PENETRATION
CLADDING
6mm GAP DO NOT
CAULK, EXTEND 25mm
"Z" FLASHING, EXTENDING
25mm EACH SIDE. 50mm
VERTICAL LEG RECOMMENDED.
FASTENERS
10mm PLASTER
BOARD LINING
90x35 MGP10
FRAME
HARDITRIM OR SIMILAR
ROOF OVERHANG, SEE PLAN
2x NAILING
RBMR2.5
INSULATIONFASTENERS
SEALANTSEALANT
4.5mm HARDIFLEX CEMENT
SHEET SOFFIT LINING
HARDITRIM OR SIMILAR
3mm GAP BETWEEN SIDING AND
TRIM, AND SEALANT AT GAP
6mm HARDIFLEX
CEMENT SHEET
EXTERIOR WALL SHEETING
(OPTIONAL)
10mm PLASTER
BOARD LINING
90x35 MGP10FRAME
Scale: 1:5, 1:20
WINDOW FLASHING DETAILS17/19
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092U
DATE: October 2018
PROPOSED EXTENSION
31 TILANBI STREET
HOWRAH
M. DUNKLEYJOB: 80901
BRICK
Received 22/10/2018
WINDOW FLASHING DETAILS18/19
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092U
DATE: October 2018
Received 22/10/2018
SPECIFICATIONS TO BCA19/19
DRAFTED BY: MATTHEW RICHARD PETTIT
ACCREDITATION No. CC5092U
DATE: October 2018
SPECIFICATIONS TO BCA " To be read in conjunction with notations as shown on "Section" sheet
" It is expected that the builder or project supervisor have access on site to a copy of the current National Construction Code
Volume 2 Building Code of Australia for their own reference.
3.1 � SITE PREPARATION
• All filling and excavations to be in accordance with Clause 3.1.1.1/2/3 and Figures 3.1.1.1/2 table 3.1.1.1
• Agricultural drains to be provided where indicated on drawings to SW outfall with silt trap as required. All in accordance
with Clause 3.1.2.2/3/4. installation as per Figure 3.1.2.4
• For slab on ground buildings the finished slab height shall be generally 150mm above the external finished surface levels
or in accordance with Clause 3.1.2.3(b) where applicable
• Grade finished external surfaces around perimeter of building outwards at 50mm over the first 1 meter
• Grade surface levels under timber/suspended floors to obviate ponding
• Stormwater drainage to comply with Clause 3.1.2.5
3.2 � FOOTINGS and SLABS
• Excavations for footings to be in accordance with Clause 3.2.2.1
• Filling and compacting under slabs to be in accordance with Clause 3.2.2.2
• Site classifications as per Engineers report. Drawings certified by the consulting engineer detailing to be used by
Contractor in all construction work
• All stump footings to be in accordance with Clause 3.2.5.6
• Fireplace footings to be in accordance with Clause 3.2.5.5
3.3 � MASONRY
• External walls to be in accordance with AS3700, AS4773 and Clause 3.3.1.2 and as shown on the drawings
• Internal walls as shown on the drawings
• Isolated piers as shown on the drawings
• Vertical articulation joints to be provided in unreinforced masonry walls for all site classifications except A and S. Joint
width to be not less than 10mm and provided at the following positions. ie"
" at 6m crs for straight, continuous walls having no openings
" at change in height of wall where the same is greater than 20%
" at 5m crs where openings occur greater than 900x900 with joint line with opening edge
" change in wall thickness
" at control and construction joints in slabs and footings
" at wall junctions of different masonry materials and at deep chases in walls
NOTE: Vertical articulation joints to be provided also in accordance with cladding manufacturers specifications
• Reinforced masonry to be in accordance with details as shown on the drawings.
• Wall ties to be provided at 600 crs vertically and at 600 crs horizontally for cavity construction and 450 crs for stud walls
• Steel lintels to be provided as noted on drawings
• Cavity width of 25mm minimum to be provided for brick veneer and 35"65mm for cavity masonry; refer to dimensions
shown on drawings
• Provide open perpends (weepholes) at 1200 crs above DPC or flashing
• Flashings to the relevant standard. Weatherproofing to single skin masonry walls in accordance with the relevant
standard
3.4 � FRAMING
• Sub floor ventilation to Clause 3.4.1.2 and Figure 3.4.1 and to be provided at the rate of 6000mm² per meter length of
wall
• Maintain 150mm minimum between surface and lowest framing member. This may be reduced if CCA or equivalent
timber is used and at the discretion of the local authority
• Steel Framing " in accordance with Part 3.4.2. Bearer and floor joist sizes as detailed on drawings
• Steel wall framing in accordance with Part 3.4.2
• All service installation in steel framing to Clause 3.4.2.6 and Figures 3.4.2.7 and 3.4.2.8
• Timber framing " all framing to AS1684.2. Timber types or composite timbers not found in AS1682.2 shall installed to the
manufacturers and/or a structural engineers specification.
• Floor framing " all bearers and joists to dimensions and sizes as shown on the drawings
• Flooring as shown on the drawings
• Wall framing " all studs, plates etc to dimensions and sizes as shown on the drawings and in accordance
• Roof framing " all members to dimensions and sizes as shown on the drawings
• Trussed roofs to be designed and manufactured by an approved supplier. Certification of same to be provided.
Trusses to be installed and braced as per manufacturers directions.
• Tie"downs " all connections to details as shown on the drawings where applicable. Construction details as shown on the
drawings. Constructions details as shown on the drawings.
• Bracing " to be provided as shown on the drawings. Construction details as shown on the drawings.
• Structural steel members " in accordance with Part 3.4.4 and to dimensions and sizes as shown on the drawings.
3.5 � ROOF AND WALL CLADDING
• Roof tiling to be in accordance with Clause 3.5.1.2 and Figures 3.5.1.1 and 3.5.1.2 to a maximum pitch of 35 degrees.
• Metal sheet roofing to be in accordance with Clause 3.5.1.3
• Gutters and downpipes as shown and indicated on the drawings and to be in accordance with Clauses in Part 3.5.2.
Calculations as shown on the drawings.
• Wall cladding as shown on the drawings if applicable and to Clauses in Part 3.5.3. Window flashings as per Figure 3.5.3.4
3.6 � GLAZING
• All glazing to AS1288 and AS2047
• Manufactured windows, doors and panels to the above Australian Standards and certified accordingly and to Clause 3.6.3 and
3.6.4 for human impact safety requirements.
3.7 � FIRE SAFETY
• External walls less than 900mm from the allotment boundary to comply with Clause 3.7.1.5 and as shown on the drawings.
• Class 10a buildings located between a Class 1 building and the allotment boundary to comply with Clause 3.7.1.6 and Figures
3.7.1.4 to 3.7.1.6
• Carports to comply with Clause 3.7.1.6(d) and Figure 3.7.1.8
• Allowable encroachments in accordance with Clause 3.7.1.7
• Separating walls to comply with Clause 3.7.1.8
• Roof sarking in Class 1 building to be of a flammability index not greater than 5 and in accordance with Clause 3.7.1.9
• Roof lights in accordance with Clause 3.7.1.10
• Smoke alarms to be installed and located in accordance with Clauses in Part 3.7.2 and as shown on the drawings.
• Heating appliances to be in accordance with Clauses in Part 3.7.3 in locations as shown on the drawings.
• Bushfire areas " proposals in designated Bushfire areas to be in accordance with Clauses in Part 3.7.4
• Alpine areas " proposals in designated Alpine areas to be in accordance with Clauses in Part 3.7.5
3.8 � HEALTH AND AMENITY
• All wet areas including showers, baths and wall fixtures to be waterproofed to AS3740 and in accordance with Clauses 3.8.1.1
to 3.8.1.6 and Figures 3.8.1.5 to 3.8.1.11.
• All wall substrates to be MR board or similar including cement sheet with water resistant linings of ceramic tile, slate, stone,
lamipanel or similar in accordance with Clause 3.8.1.5
• Wall linings as specified above to be provided to height of 1800 above shower bases, 150 above baths, handbasins and other
fixtures including washing machines.
• Shower recesses to comply with AS3740
• Wall and fixture junctions to comply AS3740.
• Room heights " as shown on the drawings and in accordance with Clause 3.8.2.2 including stairwell clearances.
• Facilities to be provided and installed in accordance with Clause 3.8.3.1 to 3.8.3.3 and as shown on the drawings.
• Doors to sanitary compartments to be in accordance with Clause 3.8.3.3 and as shown on the drawings. Clearance of 1200 to
be maintained between closet pan and nearest part of doorway. Where clearance insufficient door to open outwards or slide.
• Light " natural light to be provided at not less than 10% of the floor area of the room and as shown on the drawings and to
comply with Part 3.8.4
• Artificial light to be provided in accordance with Clause 3.8.4.3.
• Ventilation " to be provided in accordance with Clauses 3.8.5.0 to 3.8.5.2 and not less than 5% of the floor area of the room.
• Sanitary compartments as shown on the drawings and in accordance with Clause 3.8.5.3.
• Sound insulation " separating walls where required to be in accordance with Clauses in Part 3.8.6
3.9 � SAFE MOVEMENT AND ACCESS
• Stair construction as noted on drawings and in accordance with Clauses in Part 3.9.1
• Rises and goings as noted on drawings.
• Spiral stairs in accordance with this part.
• Balustrades as noted on drawings and in accordance with Clauses in Part 3.9.2. All balustrades 1000mm minimum height with
a maximum aperture of 125mm (except wire balustrade where spacing will comply with Table 3.9.2.1)
• Loading forces on balustrades to comply with AS1170.1
• Balustrades to stairs to be 865mm above stair nosing and in accordance with Clause 3.9.2.3 and Figures 3.9.2.1 to 3.9.2.3
3.12 � ENERGY EFFICIENCY
• RBM to be installed and in accordance with Clause 3.12.1.1(b).
• Bulk insulation to AS2464.3, 5 and 6 and in accordance with Clause 3.12.1.1(c).
• Roof insulation to comply with Clause 3.12.1.2 and as noted on the drawings.
• Roof lights to Clause 3.12.1.3.
• External wall insulation to be in accordance with Clause 3.12.1.4 and as noted on the drawings.
• Floor insulation to comply with Clause 3.12.1.5.
• External glazing in accordance with Clause 3.12.2.1 and as shown on the drawings.
Calculation of glazing areas as noted on the drawings.
• Building sealing in accordance with Part 3.12.3 and as noted on the drawings.
Received 22/10/2018