31 a60 aluminium deck and bulkhead profile wrap …...a60 aluminium deck and bulkhead profile wrap...
TRANSCRIPT
A6
0
alum
iniu
m d
eck
and b
ulk
head
Profile wrap system
FIR
E P
RO
TEC
TIO
N 31
A60 aluminium deck
FireMaster®Marine Plus blanket is applied using
bi-m
etallic anchors welded to the structure at a
uniform
anchor spacing of 200mm, meaning that
joints between blankets can be placed at any
point, leading to simpler installation.
Marine & O
ffshore Fire Divisions - bulkhead, deck & floor systems
32
Typical A60 system weight - 3.5kg/m
2
Marine & O
ffshore Fire Divisions - bulkhead, deck & floor systems
33
A60 aluminium deck
Profile wrap system
a
b
200mm
max 350mm
Ref. a
Product
FireMaster Marine Plus blanket
70kg/m³.
Weight
(kg/m
2)
50
Thickness
(mm)
3.5
bFireMaster Marine Plus blanket
70kg/m³.
50
3.5
FireMaster Marine Plus blanket 70kg/m
³
Marine & O
ffshore Fire Divisions - bulkhead, deck & floor systems
34
Detail of uniform
deck anchor pattern
Anchors spaced at 200mm uniform
centres across blanket width.
Joints betw
een adjacent blankets can be up to 100mm from anchor.
NB: All illustrations shown with un-taped joints
Detail of stiffener and flat layer system (main illustration right)
a
Ref. a
Product
FireMaster Marine Plus blanket
70kg/m³.
Weight
(kg/m
2)
50
Thickness
(mm)
3.5
FireMaster Marine Plus blanket 70kg/m
³
200mm
max 350mm
A60 aluminium bulkhead
Fire towards either side
Profile wrap system
Marine & O
ffshore Fire Divisions - bulkhead, deck & floor systems
35
Detail of uniform
bulkhead anchor pattern (main illustration right)
Anchors spaced at 200mm uniform
centres across blanket width.
Joints betw
een adjacent blankets can be up to 100mm from anchor.
NB: All illustrations shown with un-taped joints
Detail of stiffener and flat layer system
a
200mm
cb
Ref. a
Product
FireMaster Marine Plus blanket
70kg/m³.
Weight
(kg/m
2)
50
Thickness
(mm)
3.5
bAluminium bulkhead.
6-
FireMaster Marine Plus blanket 70kg/m
³max 350mm
200mm
cFireMaster Marine Plus blanket
70kg/m³.
50
3.5
max 350mm
A60 aluminium bulkhead
Fire towards either side
Profile wrap system
Marine & O
ffshore Fire Divisions - bulkhead, deck & floor systems
36
Detail of non-stiffened side blanket layout
Detail of FireMaster Marine Plus blanket applied
on each side of the bulkhead in one single layer
Detail of stiffened side blanket layout
Vertical anchor spacing depends on stiffener spacing
Maxim
um spacing 300mm to 350mm
NB: All illustrations shown with un-taped joints