3
Please Note:
This product should only be installed by a qualified electrician or competent heating installer, and should be in accordance with the current edition of the IEEE wiring regulations.
Specification
Power supply 230±15%Vac,50/60Hz
Switchaction 2xSPST,type1B
Switchrating Max264Vac,50/60Hz,3(1)A
Timingaccuracy ±1min/month
Enclosurerating IP30
Max.ambienttemperature 55°C
Dimensions,mm(W,H,D) 102 x 210 x 60
Designstandard EN60730-2-7
Construction Class1
ControlPollutionSituation Degree 2
RatedImpulseVoltage 2.5kV
BallPressureTest 75°C
Product specification
Installation Instructions
Specificatio
n
4
3060
Inst
alla
tion
Installation
1. Removelowersettingdial.Setallfourtappetstotopofupperdial.Unscrew4BAscrewandremoveoutercase.
2. Slackentwoscrewssecuringplug-inmoduletobackplateandseparatemodulefrombackplatebypullingupwards.
3. Fixbackplatetowall(3holefixing).
4. Referringtowiringdiagramsbelowandoppositemakeelectricalconnectionsasshown(asapplicable).Thediagramsindicatethatterminals3and5arenotinternallyconnectedtotheprogrammerandmaythereforebeusedassparewiringterminalsifrequired.
5. EaseofinstallationcanbeachievedbytheuseoftheDanfossRandallWiringCentrewhichisobtainablefrommostBuildersMerchantsandDistributors.
NOTE: If a Wiring Centre is used follow the installation instructions included with that unit and not the following wiring diagrams.
6. Securecablecoresundercableclamp.
5
Wiri
ng
Wiring
1 2 3 4 5 6 7 8 9 10S/L L N
Bro
wn
Ora
nge
Gre
yB
lue
Danfoss RandallHP22 or HP28
SRZV (Hot Water)
Bro
wn
Ora
nge
Gre
y
Blu
e
Danfoss RandallHP22 or HP28
SRZV (Heating)
Flying lead Flying lead
2
41
(N)
1 2 3 4 5 6 7
Danfoss RandallATC Cylinder Stat
2 3
1
3 core2 core3 core
Danfoss RandallRMT230 Room Stat
3060 Terminals
Mains SupplyN
L
2 core +
3 or 4 core
N N
L L
Boiler Pump
Permanent line supply for boiler if required
1 2 3 4 5 6 7
24
1
N L
Boiler
1
23 Danfoss Randall ATC Cylinder Stat
Danfoss Randall RMT230 Room Stat
N L
Pump
3060 Terminals
Mains SupplyN
L
WIRING - FULLY PUMPED SYSTEM
WIRING - GRAVITY HOT WATER SYSTEM
NOTE: This unit is NOT suitable for use with fully motorised zone valves requiring both ON and OFF electrical signals when used in the heating circuit
1 2 3 4 5 6 7 8 9 10S/L L N
Bro
wn
Ora
nge
Gre
yB
lue
Danfoss RandallHP22 or HP28
SRZV (Hot Water)
Bro
wn
Ora
nge
Gre
y
Blu
e
Danfoss RandallHP22 or HP28
SRZV (Heating)
Flying lead Flying lead
2
41
(N)
1 2 3 4 5 6 7
Danfoss RandallATC Cylinder Stat
2 3
1
3 core2 core3 core
Danfoss RandallRMT230 Room Stat
3060 Terminals
Mains SupplyN
L
2 core +
3 or 4 core
N N
L L
Boiler Pump
Permanent line supply for boiler if required
1 2 3 4 5 6 7
24
1
N L
Boiler
1
23 Danfoss Randall ATC Cylinder Stat
Danfoss Randall RMT230 Room Stat
N L
Pump
3060 Terminals
Mains SupplyN
L
WIRING - FULLY PUMPED SYSTEM
WIRING - GRAVITY HOT WATER SYSTEM
NOTE: This unit is NOT suitable for use with fully motorised zone valves requiring both ON and OFF electrical signals when used in the heating circuit
6
User Instructions
Your programmer
The3060programmerallowsyoutoswitchyourhotwaterandheatingonandoffattimesthatsuityou.
Fourtappetsonthetimingdialletyoudecidewhenyouwantyourhotwaterandheatingtocomeonandgooffeachday.Theprogrammerprovides2ONtimesand2OFFtimesperday.
UsingthelowerdialyoucanchoosehowyoucontrolyourHeatingandHotWater,eitheratthesettimes,constantlyON,constantlyOFF(eachindifferentcombinations).Duringthesummerthecentralheatingcanbeturnedoff,whilststillcontrollingthehotwateratthesettimes.
Your
Pro
gram
mer
& P
rogr
amm
ing
the
unit
Programming the unit
TherearefourTAPPETSonyourtimingdial,tworedandtwoblue: o the redtappetsaretheON switches
o the bluetappetsaretheOFF switches
1. Holdthecentralblack&silverknobwithonehandandmovetheredtappetmarked‘A’clockwise to thetimeyouwantyourHEATING/HOTWATERtoswitch oninthemorning.
NB.youmayfindthetappetsquitestiff,soyoumay
havetopushthemquitefirmlytomovethem.
7
Setti
ng th
e cl
ock
2 Stillholdingthecentralknob,movethebluetappet marked‘B’tothetimeyouwantyourHEATING/HOT WATERtoswitchoffinthemorning.
3 Youcansetyourothertwotappetsinthesameway tosetyourHEATING/HOTWATERfortheafternoon orevening.
EXAMPLE (NB.Clockisin24hourmode) IfyouwantyourheatingandhotwaterONbetween 7amand10amandONagainbetween5pmand 11pm,settappetsasfollows:
Aat1stONtime=7 Bat1stOFFtime=10 Cat2ndONtime=17 Dat2ndOFFtime=23
Setting the Clock
o Turnthedialclockwise until the correct time is lined up with the dot labelledTIME
NB.clockisin24hour mode
REMEMBER You will have to reset the time after a power cut and also when the clocks change in Spring and Autumn!
8
Using the Programmer
Theselectorswitchisusedtoselecthowthe3060controlsyourhotwaterandheating.Theheatingandhotwatercanbeoperatedtogetherinvariouscombinations,orthewatercanbecontrolledonitsown(i.e.duringthesummerwhenonlyhotwaterisrequired).
Therearesixpositionsintowhichtheselectorswitchmaybeset.
1 - H OFF / W OFF BothHeatingandHotWaterwillremainOFFuntilyou
changethesetting.
2 - H TWICE / W TWICE InthispositiontheHeatingandHotWaterwillboth
comeonandgooffaccordingtothetimesyouhaveprogrammed(ONatA,OFFatB,ONatC,OFFatD).
3-H ONCE / W ONCE ThissettingoverridestappetsBandC,soboth
HeatingandHotWaterwillswitchONatthetimemarkedbytappetAandwillstayonuntilthetimemarkedbytappetD.BothserviceswillthenswitchOFFuntil‘A’thenextday.
Usi
ng th
e pr
ogra
mm
er
H+W ON
H+W OFF
H - TWICEW - ONCE
H - ONCEW - ONCE
H - TWICEW - TWICE
H - OFFW - TWICE
9
Usi
ng th
e pr
ogra
mm
er
4 - H ON / W ON Thisisthe‘CONSTANT’positionandtheprogrammer
willremainpermanentlyONforbothHeatingandHotWater,irrespectiveofthepositionofthetappets.
5 - H TWICE / W ONCE Inthispositiontheheatingwillcomeonandgooff
accordingtothetimesyouhaveprogrammed(ONatA,OFFatB,ONatC,OFFatD).
TheHotWaterwillcomeonatAandstayonuntilD.
6 - H OFF / W TWICE InthispositiontheHeatingwillbepermanentlyOFF
andtheHotWaterwillcomeonandgooffaccordingtothetimesyouhaveprogrammed(ONatA,OFFatB,ONatC,OFFatD).
Note:
If hot water is required all day with the heating shut off (i.e. heat off, water once)
o Turntheselectorswitchto‘Htwice/Wonce’and turndowntheroomthermostattoitslowest setting.
If constant hot water is required with heating off (i.e. heat off, water on)
o Turntheselectorswitchto‘Hon/Won’andturn theroomthermostattoitslowestsetting.
10
11
Danfoss LtdAmpthillRoadBedfordMK42 9ERTel:01234364621Fax:01234219705
Still having problems?
Callyourlocalheatingengineer:
Name:
Tel:
Visitourwebsite:
www.heating.danfoss.co.uk
Emailourtechnicaldepartment:
Callourtechnicaldepartment
0845 121 7505(8.45-5.00Mon-Thurs,8.45-4.30Fri)
For a large print version of these instructions please contact the Marketing Services Department on 0845 121 7400.
PartNo.7485v0306/08