3000 apex the a prime 2500 experiment 4000 at jefferson...

25
DHF — Messina, Italy — 25 September 2014 (Me - e + e m 0 190 200 210 220 230 240 ? A 0 e - e + nucleus e - γ 1 James Beacham The Ohio State University for the APEX Collaboration APEX The A Prime EXperiment at Jefferson Lab Work done while at New York University

Upload: doanthien

Post on 08-Jun-2019

213 views

Category:

Documents


0 download

TRANSCRIPT

DHF — Messina, Italy — 25 September 2014

)2 (MeV/c- e+em180 190 200 210 220 230 240 250

Even

ts /

(0.2

)

0

500

1000

1500

2000

2500

3000

3500

4000

APEX Test Run Data, ~770K eventsAPEX Test Run Data, ~770K events

?A0

e�e+

nucleus

e�

1

James Beacham The Ohio State Universityfor the APEX Collaboration

APEXThe A Prime

EXperimentat Jefferson Lab

Work done while atNew York University

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 2

Outline

Motivations !

Existing constraints !

APEX test run setup !

Test run results !

Full run plans

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 3

U(1) extension of the Standard Model

• Common feature of many theories • “Hidden gauge boson” (“dark photon”, ) mixes kinetically with photon

hidden sector coupled to SM • Equivalent to assigning small EM charge

✏Y = ✏ cos ✓W

✏ = g0/e

✏ ⇠ 10�6 � 10�2

A0

↵0/↵ = ✏2

mA0 ⇠ MeV�GeV

Note:

�L =✏

2FY,µ⌫F 0

µ⌫

A0�⇤

✏A0�⇤

e+

e�

e

Kinetic mixing Holdom, Phys.Lett. B166 (1986) 196

• Lagrangian contains a term

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 4

Additional motivations

A sub-GeV mass for the could explain dark matter anomalies...

A0

arXiv:0906.0580

...and the anomalous magnetic moment of the muon

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014

10-3 10-2 10-1 110-11

10-10

10-9

10-8

10-7

10-6

10-5

10-4

mA' HGeVL

e2APEXTest

A1

U70

E141

E774

am

ae

BaBar

KLOE

KLOEHADES

WASA

Orsay

HPS

HPS

APEX

DarkLight

VEPP-3

5

Existing constraints

ae 2008

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 6

Existing constraints

Now

10-3 10-2 10-1 110-11

10-10

10-9

10-8

10-7

10-6

10-5

10-4

mA' [GeV]

�2APEXTest

A1PHENIX

U70

E141

E774

a�, 5�

a�,±2� favored

ae

BaBar

KLOEKLOEHADES

Orsay

HPS2015

HPS2015

APEXDarkLight

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 7

APEX: Dark photon search in fixed target experiment at Jefferson Lab

Cou

plin

g st

reng

th APEX proposal

Jefferson Lab, Newport News, VA

Hall A

Bjorken, Essig, Schuster, Toro, Wojtsekhowski, et al. proposed a fixed target experiment to be conducted at Thomas Jefferson National Accelerator Facility,

in Virginia; test run for experiment in June/July 2010

• Full run: = 65 to 525 MeV

• Test run: = 178 to 250 MeV

↵0/↵ & 10�7

mA0

mA0

↵0/↵ & 10�6

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 8

l+

l−

e−

Z

γ∗

γ

l+

l−

e−

Z

e+

e−

e−

Z

A′

γ

Signal

QED backgrounds

?

Looking for a small, narrow bump on top of a smooth histogram of QED processes; excellent mass resolution required

Direct production of at JLab • Produced via high energy e- beam incident on fixed high-Z (Ta) target

• Decays to pair with opening angle ~ mA0/Ebe+e�

⇥0 ⇡ 5�

Dipole septum magnets allow for detection of produced at

small anglese+e�

A0

Experimental signature

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 9

Top view

Jefferson Lab’s Hall A experimental apparatus

J. Huang

APEX test run: Beam current up to 150µA Target: Ta foil, 22 mg/cm2

HRS Central momenta: 1.13 GeV Momentum acc: ± 4.5% Electron beam energy: 2.26 GeV Solid angle acceptance: Left HRS: 2.8 msr Right HRS: 2.9 msr

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 10

Target enclosure (behind)

Incoming electron beam: 2.26 GeV

Outgoing electro

n

(behind)

Outgoing positron

JLab Hall A

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 11

Outgoing electr

on

Detector hut for HRS

Pipe leading to beam dump

JLab Hall A

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 12

Hall A High Resolution Spectrometers (HRSs)

Offline PID

Online PID and triggering

Timing (to ID coincident pairs)

Tracking

E. Jensen

e+e�

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014

Argon-CO2 mixture

13

Two parallel VDCs provide accurate reconstruction of full 3D track of particle as it enters the HRS

• APEX: Electron singles rate from 0.7 to 5.8 MHz

• Rates are higher than ever used in Hall A -- 5 MHz (75 kHz/wire, 368 wires)

S. Riordan

Determining mass resolution

Optics calibration • A mapping from measured coord.

at VDC to 3-momentum at target • Sieve slit method

Septum Entrance

Beam

Vertex

e’

Sieve PlateJ. Huang

Test run mass resolution: σ ~ 0.85 - 1.11 MeV(varies over mass range)

mrad Optics Tracking MS in targetσ(horiz) 0.11 ~0.4 0.37σ(vert) 0.22 ~1.8 0.37

Mass resolution depends on angular and momentum resolution

• HRS momentum resolution excellent, ; negligible

• Angular resolution and multiple scattering in target dominate

10�4

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 14

Background rejection and final dataset

Reducible backgrounds • Electron singles from inelastic or

electron-nucleon scattering • Pions from virtual photon decays • Proton singles • Accidental coincidences • pairs from real photon conversions

e+e�

e+e�

Final event sample trigger: • Double coincidence gas Cherenkov signal within 12.5 ns window in each arm

Final data sample consisted of 770500 true e+e- coincident events with 0.9% (7.4%) meson (accidental e+e- coincidence) contamination

e+/⇡+

Pion rejection: • Production ratio in right HRS:

> 1/100 • Online pion rejection: factor of 30 • Offline rejection > 1/100 using both

gas Cherenkov and calorimeters

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014

]2 [MeV/c-e+em0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9

)2Ev

ents

/ (0

.5 M

eV/c

0

1000

2000

3000

4000

5000

6000

7000

8000

9000

Signal + Bkgd

7th order polynomialBkgd only

Signal

209.5 212.5 215.5 218.5 221.5 224.5 227.5 230.5 233.5 236.5 239.5

Test mass: m = 224.5 MeVA0

]2 [MeV/c-e+em0.4 0.42 0.44 0.46 0.48 0.5 0.52 0.54 0.56 0.58 0.6

)2Ev

ents

/ (0

.5 M

eV/c

3500

4000

4500

5000

5500

6000

6500

Signal + Bkgd

7th order polynomial (zoom)Bkgd only

221.5 222.1 222.7 223.3 223.9 224.5 225.1 225.7 226.3 226.9 227.5

15

Final invariant mass spectrum QED radiative trident / Bethe-Heitler eventsBump hunt / resonance search

P (me+e� | mA0 , �, S, B, ai) =

S · N(me+e� | mA0 , �) + B · Polynomial(me+e� , ai)

S + B

�(S) =L(S, ˆB, ˆai)L(S, B, ai)

Probability model and profile

likelihood ratio

Test run mass resolution: ~ 0.85 - 1.11 MeV�

Bump hunt for small, narrow resonanceAPEX Test Run Data, ~770K events

Scanning window (raster scan)

approach, with sidebands symmetric

around mass hypothesis

Even

ts /

(0.2

MeV

/c2 )

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 16

Results from scan of test run data:Number of signal events, S, and p-values

For ~1000 pseudoexperiments based on the test run data, 40% yielded a p-value lower than 0.006

�1

�2

�3

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 17

✓↵0

max

=

✓Smax

/mA

0

f ·�B/�m

◆⇥

✓2Ne↵↵

3⇡

Upper limit on S upper limit on coupling

(See APEX proposal)

d⌃(A0)d⌃(⇥⇤)

=✓

3⇧⌅2

2Ne��

◆mA0

⇤m=

S⇥m

B�⇤

⇥m

Normalize all backgrounds to background • Ratio f of radiative-only cross section to full trident

cross section determined via Monte Carlo to vary linearly from 0.21 to 0.25 across APEX mass range

�⇤

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 18

Test run results and full run status

Test run results in PRL • prl.aps.org/abstract/PRL/v107/i19/e191804 • arXiv:1108.2750

APEX is approved; JLab currently commissioning beam after shutdown for upgrade to 12 GeV • Physics in 2015 • Both APEX and HPS selected by JLab PAC 41 for priority running (next few years)

• Equipment fully funded

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 19

Dataset now public

As of 2 October 2013

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 20

Full run at JLab will take data for ~34 days at several energy and spectrometer settings

• Possible modifications to original run plan could take advantage of higher beam energies and wider angles (with adjustment of septum magnets) to access higher mA’ region

Cover a larger mass range using a 50-cm long multifoil target

Plan for full run

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 21

Work in progress for full run

New septum magnets • Magnet parts produced • Contractor, Buckley Systems, has

finished testing coils • Magnet is currently on a ship;

further testing upon its arrival at JLab

• Sensitivity projections currently being updated with new acceptance

New optics method • Scintillating fiber (SciFi) hodoscope

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014

10-3 10-2 10-1 110-11

10-10

10-9

10-8

10-7

10-6

10-5

10-4

mA' [GeV]

�2

APEXTest

A1PHENIX

U70

E141

E774

a�, 5�

a�,±2� favored

ae

BaBar

KLOEKLOEHADES

Orsay

HPS2015

HPS2015

APEXDarkLight

Full run statistics of pairs will be ~200x larger than test run, allowing sensitivity to 1-2 orders of magnitude below current limits↵0/↵ = ✏2

e+e�

22

APEX Test Run Results

Full Run Projected Sensitivity

?

Plan for full run

JLab commissioning 12 GeV beam now — physics in 2015 (possibly Nov. 2014) • Hall A schedule still being finalized; APEX ready to run in the first or second year • New SciFi optics calibration method and septum magnets • Data acquisition rate improvements (up to 5 kHz)

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 23

APEX spokespeople • Rouven Essig (Stony Brook) • Philip Schuster (Perimeter) • Natalia Toro (Perimeter) • Bogdan Wojtsekhowski (Jefferson Lab)

Core test run analysis team • Sergey Abrahamyan (Jefferson Lab) • Eric Jensen (William & Mary) • Jin Huang (MIT) • Kyle Cranmer (NYU), J.B. (NYU/OSU)

!The Hall A Collaboration !Jefferson Lab staff

Acknowledgments

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 24

Backups

James Beacham (Ohio State) APEX DHF — Messina, Italy — 25 September 2014 25

Hall A High Resolution Spectrometers (HRSs)