Series SYJ300/500/700 3 Port Solenoid Valve Improved pilot valve Pilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M2. Flow Characteristics SYJ300 SYJ500 SYJ700 0.36 1.2 2.7 0.31 0.41 0.38 0.089 0.32 0.72 Series Flow characteristics C [dm 3 /(s·bar)] b Cv Cover (stainless steel) Rubber Seal 1369 SYJ VQZ VP VG VP3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Upload: others

Post on 10-Feb-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

  • Series SYJ300/500/7003 Port Solenoid Valve

    Improved pilot valvePilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M2.

    �Flow Characteristics

    SYJ300SYJ500SYJ700

    0.361.2 2.7

    0.310.410.38

    0.0890.32 0.72

    SeriesFlow characteristics

    C [dm3/(s·bar)] b Cv

    Cover (stainless steel)

    Rubber Seal

    1369

    SYJ

    VQZ

    VP

    VG

    VP3�

    P1369-P1430-E.qxd 08.9.2 3:26 PM Page 1369

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • SYJ300

    SYJ500

    SYJ700

    SYJ300

    SYJ500

    SYJ700

    M3 x 0.5

    M5 x 0.8

    1/8

    M5 x 0.8

    1/8

    1/8, 1/4

    Series Port sizeSonic

    conductanceC [dm3/(s·bar)]

    Type ofactuation Voltage Electrical entry

    Option

    Light/surge voltage suppressor

    Manualoverride

    Variations

    Note) All AC voltage models have built-in surge voltage suppressor.

    Bo

    dy

    po

    rted

    Bas

    e m

    ou

    nte

    d

    –+

    –+

    –+

    P.1372

    P.1386

    P.1404

    P.1404

    P.1372

    P.1386

    1370

    Series SYJ300/500/700

    Rubber Seal3 Port Solenoid Valve

    �N.C.�N.O.

    Effective area0.9 mm2

    2→3(A→R)

    0.662→3

    (A→R)

    2.52→3

    (A→R)

    1.22→3

    (A→R)

    2.72→3

    (A→R)

    � Non-locking push type

    � Push-turn locking slotted type

    � Push-turn locking lever type

    For DC

    � With surge voltage suppressor

    � With light/surge voltage suppressor

    For DC

    � 24 VDC12 VDC6 VDC5 VDC3 VDC

    For ACFor AC

    � With light/surge voltage suppressor

    �100 VAC Hz110 VAC Hz200 VAC Hz220 VAC Hz

    Note)

    Grommet

    L plugconnector

    M plugconnector

    DIN terminal

    M8 connector

    (SYJ500, 700 only)

    0.362→3

    (A→R) 506050

    6050

    6050

    60

    P1369-P1430-E.qxd 08.9.2 3:26 PM Page 1370

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • Body ported

    Base mounted

    Body ported

    Base mounted

    Body ported

    Base mounted

    1371

    Series SYJ300/500/700

    SYJ300

    SYJ500

    SYJ700

    SYJ300

    SYJ500

    SYJ700

    ø8

    Manifold Variations

    Valve series A portlocation

    Top

    Top

    Top

    Side

    Side

    Side

    Bottom

    Bottom

    M5 x 0.8

    1/8

    1/8

    1/8

    1/4

    M5 x 0.8

    1/8

    1/8

    1/8

    1/4

    1/4

    P, R portssize

    A port size

    With one-touch fitting

    Applicable tubing O.D.

    ø6ø4 N3 N7 N9

    Note 1) Only for internal pilotNote 2) Only for external pilot

    Note 1)

    Note 1)

    Note 1)

    Note 2)

    Note 1)

    M3 M5 1/8

    Bo

    dy

    po

    rted

    Bas

    e m

    ou

    nte

    d

    P.1378

    P.1392

    P.1410

    P.1378

    P.1392

    P.1410

    Series SYJ300 Series SYJ500 Series SYJ700

    SYJ

    VQZ

    VP

    VG

    VP3�

    P1369-P1430-E.qxd 08.9.2 3:26 PM Page 1371

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • SYJ71 24 SYJ7224

    SYJ71 R24 SYJ72 R24

    X X

    (A)2

    1(P)

    3(R)

    (A)2

    1(P)

    3(R)

    (A)2

    1(P)

    3(R)

    (A)2

    1(P)

    3(R)

    1404

    Series SYJ700Rubber Seal3 Port Pilot Solenoid Valve

    Body ported

    Base mounted

    Specifications

    Fluid

    Operating pressure range (MPa)

    Ambient and fluid temperature (°C)Response time ms (at 0.5 MPa) Note 1)

    Max. operating frequency (Hz)

    Manual override (Manual operation)

    Pilot exhaust method

    LubricationMounting orientationShock/Vibration resistance (m/s2) Note 2)

    Enclosure

    Internal pilot

    –10 to 50 (No freezing.)

    30 or less

    5

    Non-locking push type, push-turn locking slottedtype, push-turn locking lever type

    Air

    0.15 to 0.7

    Not required

    Unrestricted

    150/30

    Dust proof (∗ DIN terminal, M8 connector: IP65)

    Individual exhaust for the pilot valve,common exhaust for the pilot and main valve

    ∗ Based on IEC60529Note 1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20°C, at rated

    voltage, without surge voltage suppressor.)Note 2) Impact resistance: No malfunction occurred when it is tested in the axial direction and

    at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.(Value in the initial state)

    Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz.Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Value in the initial state)

    Solenoid Specifications

    Electrical entry

    Coil rated voltage (V)

    DCAC 50/60 Hz

    Standard With powersaving circuit

    Surge voltage suppressorIndicator light

    Power consumption (W) DC

    Apparent power(VA) ∗

    AC

    100 V

    110 V[115 V]

    200 V

    220 V[230 V]

    100, 110, 200, 220

    ±10% of rated voltage ∗

    0.35 (With light: 0.4 (DIN terminal with light: 0.45))

    0.1 (With light only)

    0.78 (With light: 0.81)

    1.18 (With light: 1.22)

    0.86 (With light: 0.89)[0.94 (With light: 0.97)]

    1.30 (With light: 1.34)[1.42 (With light: 1.46)]

    0.78 (With light: 0.87)

    1.15 (With light: 1.30)

    0.86 (With light: 0.97)[0.94 (With light: 1.07)]

    1.27 (With light: 1.46)[1.39 (With light: 1.60)]

    Diode (DIN terminal, varistor when non-polar types)

    LED (Neon light when AC with DIN terminal)

    Grommet (G), (H), L plug connector (L),M plug connector (M), DIN terminal (D), (Y),

    M8 connector (W)

    ∗ In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.∗ For 115 VAC and 230 VAC, the allowable voltage is –15% to +5% of rated voltage.∗ S, Z and T type (with power saving circuit) should be used within the following allowable

    voltage fluctuation range due to a voltage drop caused by the internal circuit.S and Z type: 24 VDC: –7% to +10%

    12 VDC: –4% to +10%T type: 24 VDC: –8% to +10%

    12 VDC: –6% to +10%

    Allowable voltage fluctuation

    G, H, L, M, W

    24, 12, 6, 5, 3

    D, Y

    24, 12

    JIS Symbol

    Internal pilot

    External pilot

    Made to Order(For details, refer to pages 1422 to 1423.)

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1404

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 1405

    Rubber Seal3 Port Pilot Solenoid Valve Series SYJ700

    Flow Characteristics/Mass

    Note) Value for DC. Add 3 g for AC. ( ): Without sub-plate.

    SYJ712SYJ722SYJ714SYJ724SYJ714SYJ724

    C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv1→2 (P→A) 2→3 (A→R) Valve model

    Flow characteristics Mass (g) Note)

    Grommet L/M plugconnector

    DINterminal

    Type ofactuation

    Portsize

    1/8 75

    135 (75)

    76

    136 (76)

    97

    157 (97)

    M8connector

    80

    140 (80)1/8

    1/4

    N.C. 2.82.72.92.83.02.7

    0.430.380.320.210.310.31

    0.770.720.710.700.740.68

    2.52.42.72.32.62.3

    0.510.420.340.450.330.48

    0.760.690.690.630.660.64

    N.O.N.C.N.O.N.C.N.O.

    Bodyported

    Base mounted(with sub-plate)

    External Pilot

    SYJ700RPilot valve pressure is supplied separately from the main valve pressure through the use of a separate supply port.It can be used in the vacuum (up to –100 kPa) or low pressure line with 0.15 MPa or less.

    External pilot pressure

    Main pressure

    SpecificationsApplicable model

    Operating pressure rangeMPa

    Base mounted (SYJ714R, SYJ724R)

    Note 1) For manifold base, refer to page 1410.Note 2) External pilot type body ported valves (SYJ7�2R)

    can only be used on the manifold.For body ported models with the external pilot option, please refer to page 1423.

    –100 kPa to 0.7

    0.15 to 0.7

    P, R port1/8, 1/4

    A port1/8, 1/4

    X port (External pilot)M5 x 0.8

    SYJ

    VQZ

    VP

    VG

    VP3�

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1405

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • W�: With connector cable Note 1)

    SYJ7 2 5 M 01

    SYJ7 4 5 M 01

    1

    1

    56VSR

    24 VDC12 VDC6 VDC5 VDC3 VDC

    Rated voltageDC

    1234

    100 VAC200 VAC110 VAC [115 VAC]220 VAC [230 VAC]

    AC (50/60 Hz)

    Body option

    ∗ SYJ7�2R is only for manifold use.

    Bracket

    Port size

    Nil: Without sub-plate

    (With gasket and screws)

    Manual overrideNil: Non-locking push

    type

    D: Push-turn locking slotted type

    E: Push-turn locking lever type

    Body ported

    Base mounted

    Electrical entry for G, H, L, M and W

    Nil Without light/surge voltage suppressor With surge voltage suppressor

    With light/surge voltage suppressor With surge voltage suppressor (Non-polar type)With light/surge voltage suppressor (Non-polar type)

    SZRU

    Electrical entry for D, Y

    Nil Without light/surge voltage suppressor With surge voltage suppressor (Non-polar type)With light/surge voltage suppressor (Non-polar type)

    SZ

    ∗ For AC voltage valves there is no “S” option. It is already built-in to the rectifier circuit.

    ∗ For type “R” and “U”, DC voltage is only available.∗ Power saving circuit is only available in the "Z" type.

    ∗ DOZ and YOZ are not available.

    ∗ For AC voltage valves there is no “S” option. It is already built-in to the rectifier circuit.

    Light/surge voltage suppressor

    Rc

    NPTNPTF

    G

    Thread type

    NT

    FNil

    Rc

    NPTNPTF

    G

    Thread type

    NT

    FNil

    G: Lead wire length 300 mm

    L: With lead wire (Length 300 mm)

    M: With lead wire (Length 300 mm)

    MN: Without lead wire

    D: With connector

    H: Lead wire length 600 mm

    LN: Without lead wire

    LO: Without connector

    MO: Without connector

    DO: Without connector

    Grommet L plug connector

    24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 12 VDC/100, 110, 200, 220 VACM plug connector DIN terminal

    WO: Without connector cable

    24, 12, 6, 5, 3 VDC

    M8 connector

    Electrical entry

    -+

    –+–+

    –+

    +–

    +–

    Y: With connector

    YO: Without connector

    ∗ DC specifications of type D, Y, DO and YO is only available with 12 and 24 VDC.

    ∗ For type W�, DC voltage is only available.

    ∗ Bracket is not mounted.∗ External pilot type is

    compatible with the Made-to-Order specifications (-X20).

    1406

    Series SYJ700

    How to Order

    12

    Normally closedNormally open

    Type of actuation

    3 port

    (For manifold type 20, 21R)

    Nil: Without bracketF : With bracket

    NilX20

    —Body ported external pilot

    Made to Order

    (Refer to page 1423.)

    ∗ CE-compliant: For DC only.

    NilQ

    —CE-complaint

    CE-complaint

    3 port

    For sub-plate style, mainfold type 40, 41,41R, 42, 42R

    ∗ Power saving circuit is not available in the case ofD, Y, DO, YO or W� type.

    Nil

    T

    Standard With power saving circuit

    (24, 12 VDC only)

    Coil specifications

    02: 1/4 portWith sub-plate

    01: 1/8 portWith sub-plate

    Nil: Individual pilot exhaust type

    M: Common exhaust for the pilot and main valve

    R: External pilot type∗

    R port P, E port

    R port P, E port

    Note) When placing an order for body ported solenoid valve as a single unit, mounting screws for manifold and gasket are not attached. Order them separately, if necessary. (For details, refer to page 1411.)

    ∗ LN, MN type: with 2 sockets.∗ Refer to page 1425 for the lead wire length of L and M plug connectors.∗ Refer to page 1428 for the connector assembly with cover for L and M

    plug connectors.

    ∗ DIN terminal type "Y" which conforms to EN-175301-803C (former DIN4365C) is also available. For details, refer to page 1427.

    ∗ For connector cable of M8 connector, refer to page 1429.∗ A M8 connector conforming to IEC60947-5-2 is also available.

    Refer to page 1422 for details.Note 1) Enter the cable length symbols in �. Please be sure to fill

    in the blank referring to page 1429.

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1406

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • V111 5 G

    (A)2

    N.C.

    1(P)

    3(R)

    (A)2

    1(P)

    3(R)

    N.O.

    NilSZRU

    Light/surge voltage suppressorWithout light/surge voltage suppressorWith surge voltage suppressorWith light/surge voltage suppressorWith surge voltage suppressor (Non-polar type)With light/surge voltage suppressor (Non-polar type)

    rtqye

    i

    wrtqye w

    i

    u

    5 D

    Nil Without light/surge voltage suppressor

    With surge voltage suppressor (Non-polar type)

    With light/surge voltage suppressor (Non-polar type)

    S

    Z

    ∗ DOZ and YOZ are not available.∗ For AC voltage valves there is no “S”

    option. It is already built-in to the rectifier circuit.

    ∗ Do not replace V111 (G, H, L, M, W) to V115 (DIN terminal) and vice versa when replacing pilot valve assembly only.

    Rated voltage

    Electrical entry

    Light/surge voltage suppressor

    (A)2

    3(R)

    1(P)

    (A)2

    3(R)

    1(P)

    u

    Note) Add suffix “-Q” for the CE-compliant product.

    DIN terminal(Type D)

    D With connectorDO Without connector

    With connectorWithout connector

    DIN terminal(Type Y)

    YYO

    V115

    1407

    Rubber Seal3 Port Pilot Solenoid Valve Series SYJ700

    Construction

    Component Parts Replacement PartsNo.123456

    DescriptionBodyPiston plateEnd coverPistonSpool valve assemblySpool spring

    MaterialAluminum die-casted

    ResinAluminum die-casted

    Resin–

    Stainless steel

    NoteWhiteWhiteWhite

    –––

    No.

    8—

    Description

    Pilot valveBracket assembly

    NotePart no.SYJ700-9-1(-Q)SYJ700-9-2(-Q)V111(T)-����SYJ700-19-1A

    7 Sub-plate Note)1/81/4

    Aluminumdie-casted

    How to Order Pilot Valve Assembly

    56VSR12

    3

    4

    24 VDC12 VDC6 VDC5 VDC3 VDC

    100 VAC 50/60 Hz200 VAC 50/60 Hz110 VAC 50/60 Hz[115 VAC 50/60 Hz]

    220 VAC 50/60 Hz[230 VAC 50/60 Hz]

    Rated voltage

    Nil

    T

    StandardWith power saving circuit

    (24, 12 VDC only)

    Coil specifications

    ∗ Power saving circuit is not available in the case of W� type.

    ∗ For type W�, DC voltage is only available.

    ∗ CE-compliant: For DC only.

    ∗ For AC voltage valves there is no “S” option. It is already built-in to the rectifier circuit.

    ∗ For “R” and “U”, DC voltage is only available.

    ∗ Power saving circuit is only available in the "Z" type.

    ∗ For connector cable of M8 connector, refer to page 1429.

    Note 1) Enter the cable length symbols in �. Please be sure to fill in the blank referring to page 1429.

    Note) Since V111 and V115 are CE-compliant as standard, the suffix "-Q” is not necessary.

    Electrical entryGHL

    LNLOM

    MNMOWOW�

    Grommet, 300 mm lead wireGrommet, 600 mm lead wire

    With lead wireWithout lead wireWithout connectorWith lead wireWithout lead wireWithout connectorWithout connector cableWith connector cable Note 1)

    L plug connector

    M plug connector

    M8 connector

    5 24 VDC6 12 VDC1 100 VAC 50/60 Hz2 200 VAC 50/60 Hz

    3

    4 220 VAC 50/60 Hz[230 VAC 50/60 Hz]

    110 VAC 50/60 Hz[115 VAC 50/60 Hz]

    ∗ DC specifications of type D and DO is only available with 12 and 24 VDC.

    ∗ Power saving circuit is not available in the case of D, Y, DO and YO type.

    SYJ

    VQZ

    VP

    VG

    VP3�

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1407

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 0.8

    1.5

    14.516

    23.510.9

    48.4

    25.4

    13

    23.510.9

    16.1

    18

    10

    28 25 21

    - +

    RP

    A

    28

    26

    16.1

    8

    3.6

    4

    34

    44

    36

    +-

    79.6

    72.2

    18.5

    23.5

    10.9

    31.1

    23.5

    10.9

    Pg7

    ∗ Refer to page 1429 for dimensions with connector cable.

    36

    65

    46.2

    57.5

    89.6

    90.5

    49.7

    28

    25

    21

    28

    25

    21

    23.5

    10.9

    16.1

    23.5

    10.9

    65.7

    28

    25

    21

    28

    25

    21

    1408

    Series SYJ700

    Body Ported

    Grommet (G), (H): SYJ7�2-�GH ��-01� With bracket: SYJ7�2-�GH ��-01�-F

    ∗ [ ] for AC

    31.5

    [38.

    5]

    70.6 [72.8]

    ø1.6(PE port)

    2 x ø3.2(For mounting)

    G: Approx. 300H: Approx. 600

    (Lead wire length)

    1/8(A port)

    (Light/surge voltage suppressor)

    1/8(P, R port)

    Manual override

    2 x ø3.2(For manifold mounting)

    74.2

    [76.

    4]

    31.5 [38.5]

    (Bracket)

    2 x ø4.5(For mounting)

    L plug connector (L):SYJ7�2-�L��-01� (-F)

    M plug connector (M):SYJ7�2-�M��-01� (-F)

    DIN terminal (D, Y):SYJ7�2-�DY��-01� (-F)

    M8 connector (WO):SYJ7�2-�WO��-01� (-F)

    Approx. 300(Lead wire length)

    42.6 [49.6]

    Applicable cable O.D. ø3.5 to ø7

    2 x ø3.2(For mounting)

    2 x ø3.2(For mounting)

    M8 x 1Max

    . 10

    31.5 [38.5]

    App

    rox.

    300

    (Lea

    d w

    ire le

    ngth

    )80

    .5 [8

    2.7]

    70.7

    [72.

    9]

    2 x ø3.2(For mounting)

    2 x ø3.2(For mounting)

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1408

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 20

    48.5

    40 4

    54.5

    42.6

    26 X

    A

    R P

    18

    20

    25

    1212

    48

    23 15

    3427+-

    54.520

    12

    54.520

    12

    ∗ Refer to page 1429 for dimensions with connector cable.

    Pg7

    62.545

    79.7

    72.38

    9.6

    91.584

    72.7

    90.6

    57.654.5

    2012

    48 23

    15

    54.520

    12

    48 23

    15

    65.8

    48 23

    15

    42.6

    48 23

    15

    M8 x 1

    Applicable cable O.D.ø3.5 to ø7

    Max

    . 10

    69.1 [76.1]

    70.8

    [73]

    Approx. 300 (Lead wire length)

    58 [65]

    App

    rox.

    300

    (L

    ead

    wire

    leng

    th)

    80.6

    [82.

    8]

    1409

    Rubber Seal3 Port Pilot Solenoid Valve Series SYJ700

    Grommet (G), (H): SYJ7�4-�GH ��- �

    Base Mounted (With Sub-plate)

    0102

    ∗ [ ] for AC

    70.7 [72.9]G: Approx. 300H: Approx. 600

    (Lead wire length)

    Manual override

    58 [6

    5]

    (Light/surge voltage suppressor)

    1/4, 1/8 port(A port)

    M5 x 0.8(SYJ714R: X port)

    2 x ø4.5(For mounting)

    1/4, 1/8(P, R port)

    L plug connector (L): SYJ7�4-�L��- �

    M plug connector (M):SYJ7�4-�M��- �0102

    0102

    DIN terminal (D, Y):SYJ7�4-�DY��- �

    0102

    M8 connector (WO):SYJ7�4-�WO��- �0102

    SYJ

    VQZ

    VP

    VG

    VP3�

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1409

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 1410

    Manifold Specifications

    Model

    Manifold type

    P (SUP), R (EXH)

    Valve stationsA portPorting specifications

    Port size

    For internal pilot

    For external pilot

    Type 20 Type 21

    Type 21R

    Type 40

    Location

    Direction

    P, R port

    A port

    X port Note)

    Valve

    Top

    M3 x 0.8

    Single base/B mount

    Common SUP, common EXH

    2 to 20 stations

    Base

    Bottom1/8

    Note) Only for external pilot

    Type 41

    Type 41R

    Type 42

    Type 42R

    Base

    Bottom

    Base

    Side1/4

    M5 x 0.8

    1/4

    M5 x 0.8

    1/41/8

    Valve

    Top

    1/8 1/8

    1/8

    C6

    C8

    1/81/8 ø6 one-touchfittingø8 one-touchfitting

    Manifold SpecificationsSeries SYJ700

    Flow Characteristics

    Note) Value at manifold base mounted, 2 position single operating

    Type SS3YJ7-20Type SS3YJ7-21Type SS3YJ7-40Type SS3YJ7-41

    Type SS3YJ7-42-01Type SS3YJ7-42-C6

    Type SS3YJ7-42-C8

    Type SS3YJ7-21R

    Type SS3YJ7-41RType SS3YJ7-42R-01Type SS3YJ7-42R-C6Type SS3YJ7-42R-C8

    C[dm3/(s•bar)]

    1(P), 3(R)port

    2(A)port b Cv

    C[dm3/(s•bar)] b Cv

    1→2 (P→A) 2→3 (A→R)Manifold

    Flow characteristicsPort size

    1/8 2.22.22.12.22.01.62.1

    2.2

    2.22.01.62.1

    0.340.390.350.350.270.320.24

    0.34

    0.350.270.320.24

    0.550.590.590.590.470.390.51

    0.55

    0.590.470.390.51

    2.32.42.32.42.22.22.3

    2.4

    2.42.22.22.3

    0.270.320.270.360.320.270.31

    0.32

    0.360.320.270.31

    0.590.620.540.660.560.540.59

    0.62

    0.660.560.540.59

    1/81/81/81/8C6C8

    1/8

    1/81/8C6

    1/81/41/81/4

    1/41/4

    1/4

    1/4

    1/41/41/4

    C81/4

    SYJ7�2

    SYJ7�4

    SYJ7�2R

    SYJ7�4R

    Body portedfor internal pilot

    Base mountedfor internal pilot

    Body portedfor external pilot

    Base mountedfor external pilot

    How to Order Manifold (Example)

    Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no.

    (Example)SS3YJ7-20-03 ............. 1 set (manifold base)SYJ712-5LZ-01 ......... 2 sets (valve)SYJ700-10-1A ............. 1 set (blanking plate assembly)

    SS3YJ7-42R-03-01 .... 1 set (manifold base)SYJ714R-5G ............... 2 sets (valve)SYJ700-10-2A ............. 1 set (blanking plate

    assembly)The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

    ∗∗

    ∗∗

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1410

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • Base mounted (Type SYJ7�4(-Q))

    Applicable baseType SS3YJ7-20(-Q)Type SS3YJ7-21(-Q)Type SS3YJ7-21R(-Q)

    Applicable base Sub-plate Type SS3YJ7-40(-Q)Type SS3YJ7-41(-Q)Type SS3YJ7-42(-Q)Type SS3YJ7-41R(-Q)Type SS3YJ7-42R(-Q)

    ManifoldbaseManifold

    base

    Gasket Gasket

    SYJ700-5-3 SYJ700-5-4

    Part no.: SYJ700-10-2A(In common for body ported type and base mounted type)

    Gasket

    Blanking plate

    Round head combination screwRound head combination screwM3 x 31, Matt nickel plated

    Round head combination screwM3 x 31, Matt nickel plated

    Applicable base

    Type SS3YJ7-40-QType SS3YJ7-41-QType SS3YJ7-42-QType SS3YJ7-41R-QType SS3YJ7-42R-Q

    Manifoldbase

    Part no.: SYJ700-10-2A-1-Q

    Part no.: SYJ700-10-2A-2-Q

    Gasket

    Manifold gasket

    Applicable base Type SS3YJ7-20-QType SS3YJ7-21-QType SS3YJ7-21R-Q

    Manifoldbase

    CautionMounting screw tightening torques

    M3: 0.8 N·m

    Use caution to the assembly orientation for solenoid valves, gasket and optional parts.

    Blanking Plate Assembly

    1411

    Body ported (Type SYJ7�2(-Q))

    Rubber Seal3 Port Pilot Solenoid Valve Series SYJ700

    Combinations of Solenoid Valve, Manifold Gasket and Manifold Base

    SYJ

    VQZ

    VP

    VG

    VP3�

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1411

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • SS3YJ7 20 05

    How to Order

    SS3YJ7 40 05 01

    SS3YJ7 41R 05 01

    01 1/8A port size

    SS3YJ7 21R 05

    SS3YJ7 42 05 C6

    01C6C8N7N9

    1/8ø6 one-touch fittingø8 one-touch fitting

    ø1/4" one-touch fittingø5/16" one-touch fitting

    A port size

    SS3YJ7 42R 05 01

    01C6C8N7N9

    1/8ø6 one-touch fittingø8 one-touch fitting

    ø1/4" one-touch fittingø5/16" one-touch fitting

    A port size

    01 1/8A port size

    02:

    20

    2 staitions:

    20 staitions

    Stations

    02:

    20

    2 stations:

    20 stations

    Stations

    RcG

    NPTNPTF

    P, R port thread type

    00F00N00T

    Nil

    RcG

    NPTNPTF

    P, R port thread type

    FNT

    Nil

    RcG

    NPTNPTF

    P, R port thread type

    FNT

    Nil

    RcG

    NPTNPTF

    P, R port thread type

    00F00N00T

    Nil

    RcG

    NPTNPTF

    P, R port thread type

    FNT

    Nil

    RcG

    NPTNPTF

    P, R port thread type

    FNT

    Nil

    Nil

    Q

    CE-complaint

    CE-complaint

    Nil

    Q

    CE-complaint

    CE-complaint

    Nil

    Q

    CE-complaint

    CE-complaint

    Nil

    Q

    CE-complaint

    CE-complaint

    Nil

    Q

    CE-complaint

    CE-complaint

    Nil

    Q

    CE-complaint

    CE-complaint

    Applicable solenoid valveSYJ712-����-01(-Q)SYJ712M-����-01(-Q)SYJ722-����-01(-Q)SYJ722M-����-01(-Q)Applicable blankingplate assemblyRefer to page 1411.

    Applicable solenoid valveSYJ714-����(-Q)SYJ714M-����(-Q)SYJ724-����(-Q)SYJ724M-����(-Q)

    Applicable blankingplate assemblyRefer to page 1411.

    Applicable solenoid valveSYJ714-����(-Q)SYJ714M-����(-Q)SYJ724-����(-Q)SYJ724M-����(-Q)

    Applicable blankingplate assemblyRefer to page 1411.

    Applicable solenoid valveSYJ712R-����-01(-Q)SYJ722R-����-01(-Q)

    Applicable blankingplate assemblyRefer to page 1411.

    Applicable solenoid valveSYJ714R-����(-Q)SYJ724R-����(-Q)

    Applicable blankingplate assemblyRefer to page 1411.

    Applicable solenoid valveSYJ714R-����(-Q)SYJ724R-����(-Q)

    Applicable blankingplate assemblyRefer to page 1411.

    Type 40/Type 41

    How to Order

    -+

    -+

    -+

    -+

    RP

    -+

    -+

    -+

    -+

    RP

    Type 20/Type 21

    Note) If there are more than 6 stations for type 20, or more than 9 stations for type 21, supply air to both sides of P port and exhaust air from both sides of R port.

    How to Order

    Note) If there are more than 6 stations for type 40, or more than 9 stations for 41 type, supply air to both sides of P port and exhaust air from both sides of R port.

    Type 21R How to Order

    Note) For more than 9 stations, supply air to both sides of P port and exhaust air from both sides of R port.

    Pilot valve pressure is supplied separately from the main valve pressure through the use of a separate supply port.It can be used in the vacuum (up to –100 kPa) or low pressure line with 0.15 MPa or less.

    How to Order

    Note) For more than 9 stations, supply/exhaust air to/from both sides of P and R port.

    How to Order

    Note) For more than 9 stations, supply/exhaust air to/from both sides of P and R port.

    Note) For more than 9 stations, supply/exhaust air to/from both sides of P and R port.

    Type 42R

    -+

    -+

    -+

    -+

    PR

    X

    Type 41R

    A

    A

    R

    PX

    -+

    -+

    -+

    -+

    PR

    X

    Type 42

    A

    A

    A

    A

    -+

    -+

    -+

    -+A

    A

    PR

    X

    1412

    Series SYJ700

    Manifold for Internal Pilot Type

    P port 1/8

    R port 1/8

    A port1/8

    P port 1/4

    R port 1/4

    A port1/8

    2021

    Type 20Type 21

    Manifold type

    A port 1/8

    P port 1/4

    R port 1/4

    A port 1/8

    P port 1/8

    R port 1/8

    4041

    Type 40Type 41

    Manifold type

    A port1/8

    P port 1/4

    R port 1/4 02

    :20

    2 stations:

    20 stations

    Stations

    Manifold for External Pilot Type

    A port 1/8

    R port 1/4

    X port(External pilot)

    M5 x 0.8

    P port

    02:

    20

    2 stations:

    20 stations

    Stations

    A port 1/8

    P port 1/4

    X port(External pilot)M5 x 0.8

    R port 1/4

    02:

    20

    2 stations:

    20 stations

    Stations

    P port 1/4

    X port(External pilot)M5 x 0.8

    R port 1/4

    A port1/8

    02:

    20

    2 stations:

    20 stations

    Stations

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1412

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • RP

    RP

    25

    5

    10.5

    39238

    L2L1

    19.5

    3.4

    25.4

    53.5

    41.6

    20

    1.5

    AAAA+-+-+-+-

    Pg7

    76.7 69

    .3

    61.5

    44

    89.6

    71.7

    90.5

    83

    3.453.5 53.5

    3.4

    3.4

    41.6

    53.5

    65.7

    53.53.

    4

    1413

    Rubber Seal3 Port Pilot Solenoid Valve Series SYJ700

    Grommet (G)

    Type 20 Manifold: Top Ported/SS3YJ7-20- Stations (-00�) ∗ [ ] for AC

    70.6

    [72.

    8]

    48.4

    (DIN

    49.

    7)

    App

    rox.

    300

    (L

    ead

    wire

    le

    ngth

    )57

    [64]

    (Pitch)P=19

    (Light/surge voltage suppressor)

    1/8(P, R port)

    Manual override

    1/8(A port)

    2 x ø5.5(For mounting)

    (Station n) (Station 1)

    L plug connector (L) M plug connector (M) DIN terminal (D, Y) M8 connector (WO)

    ∗ Refer to page 1429 for dimensions with connector cable.

    68.1 [75.1]

    M8 x 1

    Applicable cable O.D.ø3.5 to ø7

    Approx. 300 (Lead wire length)

    57 [64]

    App

    rox.

    300

    (L

    ead

    wire

    leng

    th)

    80.5

    [82.

    7]

    70.7

    [72.

    9]

    Max

    . 10

    Station nL1L2

    Station 25949

    37868

    49787

    5116106

    6135125

    7154144

    8173163

    9192182

    10211201

    11230220

    12249239

    13268258

    14287277

    15306296

    16325315

    17344334

    18363353

    19382372

    Station 20401391

    SYJ

    VQZ

    VP

    VG

    VP3�

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1413

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 21.5

    14

    4322.5

    9.5

    6L2L1

    21.5

    35

    63.5

    51.6

    1.5

    21

    26

    RP

    RP

    AAAA

    +-+-+-+-

    Pg7

    71.5

    54

    80.2 72.8

    90.2

    81.7

    100.5

    93

    63.5 63.5

    91.1

    51.6

    63.563.5

    66.3

    1414

    Series SYJ700

    Grommet (G)

    Type 21 Manifold: Top Ported/SS3YJ7-21- Stations (-00�) ∗ [ ] for AC

    71.2

    [73.

    4]A

    ppro

    x. 3

    00

    (Lea

    d w

    ire

    leng

    th)

    49(D

    IN 5

    0.3)

    67 [7

    4]

    Manual override

    1/8(A port)

    2 x ø5.5(For mounting)

    (Pitch)P=19

    (Station 1)(Station n)

    (Light/surge voltage suppressor)

    1/4(P, R port)

    L plug connector (L) M plug connector (M) DIN terminal (D, Y) M8 connector (WO)

    78.1 [85.1]

    ∗ Refer to page 1429 for dimensions with connector cable.

    M8 x 1

    Applicable cable O.D.ø3.5 to ø7

    Max

    . 10

    Approx. 300 (Lead wire

    length)

    67 [74]

    App

    rox.

    300

    (L

    ead

    wire

    leng

    th)

    81.1

    [83.

    3]

    71.3

    [73.

    5]

    Station nL1L2

    Station 26149

    38068

    49987

    5118106

    6137125

    7156144

    8175163

    9194182

    10213201

    11232220

    12251239

    13270258

    14289277

    15308296

    16327315

    17346334

    18365353

    19384372

    Station 20403391

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1414

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 5L2L1

    39238

    20

    19.5

    238

    2519

    .53.

    4

    10.553.5

    PR

    RP

    41.6

    20

    +-+-+-+-

    Pg7

    61.544

    79.6

    72.2

    89.6

    90.58371.7

    3.4

    87.1

    3.453.5 53.5

    3.4

    3.4

    41.6

    65.7

    53.553.5

    1415

    Rubber Seal3 Port Pilot Solenoid Valve Series SYJ700

    Grommet (G)

    Type 40 Manifold: Top Ported/SS3YJ7-40- Stations -01� ∗ [ ] for AC

    70.6

    [72.

    8]

    48.4

    (DIN

    49.

    7)

    Appr

    ox. 3

    00

    (Lea

    d w

    ire

    leng

    th)

    1/8(A port)

    57 [6

    4]

    (Pitch)P=19

    (Pitch)P=19

    Manual override

    2 x ø5.5(For mounting)

    (Light/surge voltage suppressor)

    (Station n) (Station 1)

    1/8(P, R port)

    L plug connector (L) M plug connector (M) DIN terminal (D, Y) M8 connector (WO)

    68.1 [75.1]

    ∗ Refer to page 1429 for dimensions with connector cable.

    M8 x 1

    Applicable cable O.D.ø3.5 to ø7

    Max

    . 10

    Approx. 300 (Lead wire length)

    App

    rox.

    300

    (L

    ead

    wire

    leng

    th)

    80.5

    [82.

    7]

    70.7

    [72.

    9]

    57 [64]

    Station nL1L2

    Station 25949

    37868

    49787

    5116106

    6135125

    7154144

    8173163

    9192182

    10211201

    11230220

    12249239

    13268258

    14287277

    15306296

    16325315

    17344334

    18363353

    19382372

    Station 20401391

    SYJ

    VQZ

    VP

    VG

    VP3�

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1415

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 35

    35

    42.9

    22.5

    9.5

    21.5

    146L2L1

    21.5

    8.5

    21

    51.6

    AA

    21

    51.6

    9.5

    (4.9

    )

    63.5

    21

    AA

    R

    R

    P

    P

    +-+-+-+-

    +-+-+-+-

    Pg7

    54

    71.5

    80.2 72.8

    90.2

    100.5

    93

    81.7

    63.5 63.5

    91.1

    63.563.5

    66.3

    71.3

    [73.

    5]

    1416

    Series SYJ700

    Type 42 Manifold: Top Ported/SS3YJ7-42- Stations -01, , �N7N9C6C8 ∗ [ ] for AC

    Grommet (G)For � (Built-in one-touch fitting)N7N9C6,C8,

    For 1/8

    71.2

    [73.

    4]A

    ppro

    x. 3

    00

    (Lea

    d w

    ire

    leng

    th)

    49(D

    IN 5

    0.3)

    (Pitch)P=19

    1/8(A port)

    67 [7

    4]

    (Light/surge voltage suppressor)

    (Pitch)P=19

    67 [7

    4]

    (Pitch)P=19 Manual override

    (Station 1)

    2 x ø5.5(For mounting)

    (Station n)

    (Light/surge voltage suppressor)

    One-touch fitting(A port)

    Applicable tubing O.D.:ø6, ø1/4", ø8, ø5/16"

    1/4(P, R port)

    L plug connector (L) M plug connector (M) DIN terminal (D, Y) M8 connector (WO)

    78.1 [85.1]

    ∗ Refer to page 1429 for dimensions with connector cable.

    M8 x 1

    Applicable cable O.D.ø3.5 to ø7

    Max

    . 10

    Approx. 300 (Lead wire length)

    67 [74]

    51.6

    App

    rox.

    300

    (L

    ead

    wire

    leng

    th)

    81.1

    [83.

    3]

    Station nL1L2

    Station 26149

    38068

    49987

    5118106

    6137125

    7156144

    8175163

    9194182

    10213201

    11232220

    12251239

    13270258

    14289277

    15308296

    16327315

    17346334

    18365353

    19384372

    Station 20403391

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1416

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 21

    24

    278

    35

    AA

    51.6

    +-+-+-+-

    (Pitch)P=191/8

    (A port)

    (Light/surge voltage suppressor)

    67 [7

    4]

    1417

    Rubber Seal3 Port Pilot Solenoid Valve Series SYJ700

    ∗ [ ] for ACType 41 Manifold: Top Ported/SS3YJ7-41- Stations -01�

    Grommet (G)

    SYJ

    VQZ

    VP

    VG

    VP3�

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1417

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 35

    6

    21.5

    L2L1 30.5

    21.5

    14

    4322.5

    9.5

    6

    63.5

    26

    21

    1.5

    51.6

    X

    P

    R

    AAA

    +-+-+-+-

    A

    Pg7

    X

    P

    R

    X

    P

    R

    80.2 72.8

    71.5

    54

    100.5

    93

    81.7

    90.2

    91.1

    63.5 63.5

    51.6

    63.5

    66.3

    63.5

    X

    P

    R

    X

    P

    RGrommet (G)

    Type 21R Manifold: Top Ported (External Pilot Type)/SS3YJ7-21R- Stations (-00�) ∗ [ ] for AC

    1418

    Series SYJ700

    71.2

    [73.

    4] 49(D

    IN 5

    0.3)

    App

    rox.

    300

    (L

    ead

    wire

    le

    ngth

    )

    1/8(A port)

    (Pitch)P=19

    67 [7

    4]

    M5 x 0.8(X port)

    1/4(P, R port)

    Manual override

    (Station 1)

    2 x ø5.5(For mounting)

    (Station n)

    (Light/surge voltage suppressor)

    L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO)

    78.1 [85.1]

    ∗ Refer to page 1429 for dimensions with connector cable.

    M8 x 1

    Applicable cable O.D.ø3.5 to ø7

    Max

    . 10

    67 [74]

    App

    rox.

    300

    (L

    ead

    wire

    leng

    th)

    Approx. 300 (Lead wire

    length)

    71.3

    [73.

    5]

    81.1

    [83.

    3]

    Station nL1L2

    Station 26149

    38068

    49987

    5118106

    6137125

    7156144

    8175163

    9194182

    10213201

    11232220

    12251239

    13270258

    14289277

    15308296

    16327315

    17346334

    18365353

    19384372

    Station 20403391

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1418

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 35

    6

    6L2L1

    21.5

    30.5

    21.5

    14

    42.9

    22.5

    9.5

    21

    63.5

    AA

    9.5

    21

    51.6

    RP

    X+- +- +- +-

    21

    358.

    5

    AA51

    .6

    +-+-+-+-

    Pg7

    X

    PR

    X

    PR

    80.2

    72.8

    71.554

    100.59381.7

    90.2

    91.1

    63.5 63.5

    51.6

    66.3

    63.563.5

    RP

    X

    RP

    X

    1419

    Rubber Seal3 Port Pilot Solenoid Valve Series SYJ700

    Grommet (G)

    Type 42R Manifold: Side Ported/SS3YJ7-42R- Stations -01, , �N7N9C6C8 ∗ [ ] for AC

    For 1/8

    71.2

    [73.

    4]

    (Pitch)P=19

    Appr

    ox. 3

    00

    (Lea

    d wi

    re

    lengt

    h)49

    (DIN

    50.

    3)

    M5 x 0.8(X port)

    (Pitch)P=19

    67 [7

    4]

    One-touch fitting(A port)

    Applicable tubing O.D.:ø6, ø1/4", ø8, ø5/16"

    Manualoverride

    2 x ø5.5(For mounting)

    (Light/surge voltage suppressor)

    (Station n) (Station 1)

    1/4(P, R port)

    (Pitch)P=19

    67 [7

    4]

    1/8(A port)

    (Light/surge voltage suppressor)

    L plug connector (L) M plug connector (M) M8 connector (WO)DIN terminal (D)

    M8 x 1

    78.1 [85.1]

    ∗ Refer to page 1429 for dimensions with connector cable.

    Applicable cable O.D.ø3.5 to ø7

    Max

    . 10

    Approx. 300 (Lead wire length)

    67 [74]

    App

    rox.

    300

    (L

    ead

    wire

    leng

    th)

    81.1

    [83.

    3]

    71.3

    [73.

    5]

    Station nL1L2

    Station 26149

    38068

    49987

    5118106

    6137125

    7156144

    8175163

    9194182

    10213201

    11232220

    12251239

    13270258

    14289277

    15308296

    16327315

    17346334

    18365353

    19384372

    Station 20403391

    SYJ

    VQZ

    VP

    VG

    VP3�

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1419

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 35

    21

    24

    278

    51.6

    +-+-+-+-

    1420

    Series SYJ700

    Type 41R Manifold: Bottom Ported (External Pilot Type)/SS3YJ7-41R- Stations -01� ∗ [ ] for AC

    Grommet (G)

    (Pitch)P=19

    67 [7

    4]

    1/8(A port)

    (Light/surge voltage suppressor)

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1420

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • SYJ 2 5 WAO M5

    SYJ 4 5 WAO 01

    15

    5 1

    12

    Normally closedNormally open

    Type of actuation

    357

    SYJ300SYJ500SYJ700

    Series M501

    M5 x 0.8 1/8 (SYJ700 only)

    Port size

    56VSR

    24 VDC12 VDC6 VDC5 VDC3 VDC

    Rated voltageDC

    3 port(Manifold types 20, 20R, 21R)

    3 port Body option

    Nil

    Bracket

    Port size

    Light/surge voltage suppressor

    Body ported

    Base mounted

    Rc

    NPTNPTF

    G

    Thread type

    NT

    FNil

    Electrical entry

    5 WAOV111

    M8 connectorWAO Without connectorWA� With connector Note)

    Note) Enter the cable length symbols in �. Please be sure to fill in the blank referring to page 1429.

    Light/surge voltage suppressor

    Electrical entry

    Rated voltage

    Nil Non-locking push typeD Push-turn locking slotted typeE Push-turn locking lever type

    Manual override

    Pilot valve individual exhaust

    MCommon exhaust type for main and pilot valve

    R External pilot∗ Nil Without sub-plate

    SYJ500SYJ700

    SYJ700

    SYJ300

    011/8 port

    With sub-plate

    M5M5 port

    With sub-plate

    021/4 port

    With sub-plate

    Nil Without bracketF With bracket

    NilX20

    —Body ported external pilot(Refer to page 1423.)

    Made to Order

    ∗ X20 for Series SYJ300 is not available.

    NilQ

    —CE-complaint

    CE-complaint

    ∗ SYJ3�2R, SYJ5�2R, SYJ7�2R are only for manifold use.

    5 24 VDC6 12 VDCV 6 VDCS 5 VDCR 3 VDC

    DC

    Nil Without light/surge voltage suppressor With surge voltage suppressor

    With light/surge voltage suppressor With surge voltage suppressor (Non-polar type)With light/surge voltage suppressor (Non-polar type)

    SZRU

    Nil Without light/surge voltage suppressor With surge voltage suppressor

    With light/surge voltage suppressor With surge voltage suppressor (Non-polar type)With light/surge voltage suppressor (Non-polar type)

    SZRU

    WAO: Without connector

    WA�: With connector Note)

    Note) Enter the cable length symbols in �. Please be sure to fill in the blank referring to page 1429.

    Since V111 is CE-compliant as standard, the suffix "-Q” is not necessary.

    1422

    M8 Connector Conforming to IEC60947-5-2Series SYJ300/500/700Made to Order

    How to Order Valve

    Sub-plate type, manifold types 40, 40R, 41, 41R, S41, 42, S42, 42R, S42R

    How to Order Pilot Valve Assembly

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1422

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • How to Order Applicable solenoid valve series/SYJ5�2R, SYJ7�2R

    SYJ 57 2R X20

    Entry is the same as standard products.

    X X(A)2

    1(P)

    3(R)

    (A)2

    1(P)

    3(R)

    Operating Pressure Range MPaOperating pressure range

    Pilot pressure range

    –100 kPa to 0.7

    0.15 to 0.7

    External Pilot Port

    DimensionsSYJ500: 8 mm longer in total lengthSYJ700: 8 mm longer in total length

    JIS Symbol

    Body portedN.C. N.O.

    Series

    SYJ500, SYJ700

    Port size

    M5 x 0.8

    1423

    For detailed specifications, delivery and pricing, please contact SMC.

    Series SYJ500/700Made to Order

    Body Ported External Pilot

    SYJ

    VQZ

    VP

    VG

    VP3�

    007-SYJ.qxd 10.5.28 1:54 PM Page 1

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 1424

    Series SYJ300/500/700Specific Product Precautions 1Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.

    � Non-locking push type [Standard]Press in the direction of the arrow

    � Push-turn slotted locking type [Type D]

    Locked position

    � Push-turn locking lever type [Type E]

    Locked position

    PU

    SH

    LOC

    K

    Caution

    Manual Override Operation

    Warning

    While pressing, turn in the direction of the arrow.If it is not turned, it can be operated the same way as the non-locking type.

    When operating the locking type D with a screw driver, turn it gently using a watchmakers screw driver.[Torque: Less than 0.1 N.m]

    While pressing, turn in the direction of the arrow.If it is not turned, it can be operated the same way as the non-locking type.

    When the manual override is operated, connected equipment will be actuated. Confirm safety before operating.

    Caution

    When locking the manual override on the push-turn locking types (D, E), be sure to push it down before turning.Turning without first pushing it down can cause damage to the manual override and trouble such as air leakage, etc.

    PU

    SH

    LOC

    K

    Solenoid valves with grommet and L/M type plug connector AC specifications have a built-in rectifier circuit in the pilot section to operate the DC coil.With 200, 220 VAC specification pilot valves, this built-in rectifier generates heat when energized. The surface may become hot depending on the energized condition; therefore, do not touch the solenoid valves.

    Solenoid Valve for 200, 220 VAC Specifications

    Warning

    Pilot air is exhausted through the main valve body rather than directly to atmosphere.• Suitable for applications where exhausting the pilot valve to

    atmosphere would be detrimental to the surrounding working environment.

    • For use in extremely dirty environments where there is the possibility that dust could enter the pilot exhaust and damage the valve.

    Ensure that the piping of exhaust air is not too restrictive.

    Common Exhaust Type for Main and Pilot Valve

    Caution

    Bracket

    For bracket attached styles of SYJ300, do not use it without bracket.

    Caution

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1424

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 1425

    3. Attaching and detaching sockets with lead wires• Attaching Insert the sockets into the square holes of the connector (+, – indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector. (When they are pushed in, their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the lead wires.• DetachingTo detach a socket from a connector, pull out the lead wire while pressing the socket’s hook with a stick having a thin tip (approx. 1 mm). If the socket will be used again, first spread the hook outward.

    How to Order Connector Assembly

    For DC: SY100 30 4A

    For 100 VAC: SY100 30 1A

    Without lead wire: SY100 30 A

    For other voltages of AC: SY100 30 3A

    Lead wire lengthNil 6101520253050

    300 mm600 mm

    1000 mm1500 mm2000 mm2500 mm3000 mm5000 mm

    For DCSYJ312-5LO-M3SY100-30-4A-20

    For ACSYJ312-1LO-M3SY100-30-1A-20

    For 200 VAC: SY100 30 2A

    (with connector and 2 of sockets only)

    How to Order Include the connector assembly part number together with the part number for the plug connector’s solenoid valve without connector.

    EX.) In case of 2000 mm of lead wire

    Connector

    Lead wire

    Socket

    Hook

    Lead wire Socket

    Crimping areaCore wire crimping area

    Hook Insulation

    0.2 to 0.33 mm2 Max. cover diameter: ø1.7 mm

    Core wire

    2. Crimping of lead wires and sockets Strip 3.2 to 3.7 mm at the end of the lead wires, insert the ends of the core wires evenly into the sockets, and then crimp with a crimping tool. When this is done, take care that the coverings of the lead wires do not enter the core wire crimping area.Use an exclusive crimping tool for crimping.(Contact SMC for special crimping tools.)

    Socket

    Hook

    Lead wire

    DC Polarity displayLever

    Connector

    Pin

    GrooveCover

    Pin

    Groove

    Cover

    -+

    1. Attaching and detaching connectors• To attach a connector, hold the lever and connector unit

    between your fingers and insert straight onto the pins of the solenoid valve so that the lever’s pawl is pushed into the groove and locks.

    • To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out.

    CautionHow to Use Plug Connector

    Standard length is 300 mm, but the following lengths are also available.

    CautionPlug Connector Lead Wire Length

    Series SYJ300/500/700Specific Product Precautions 2Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.

    SYJ

    VQZ

    VP

    VG

    VP3�

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1425

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • DIN terminal has no polarity.

    • Connect the standard type in accordance with the +, – polarity indication. (The non-polar type can be used with the connections made either way.)

    • Since voltage specifications other than standard 24 and 12 VDC do not have diodes for polarity protection, be careful not to make errors in the polarity.

    • Please use caution regarding the allowable voltage fluctu-ation because there is about a 1 volt drop for a valve with polarity protection. (For details, refer to the solenoid specifi-cations for the individual valve.)

    • When wiring is done at the factory, positive (+) is red and negative (–) is black.

    Operating Principle

    (In the case of SYJ ��T, the electric wave form of energy saving type)

    357

    Applied voltage

    StandardWith power

    saving circuit

    62 ms

    24 V

    0 V

    0.4 W

    0.1 W

    0 W

    � With power saving circuit Electric circuit (with power saving circuit)

    1: Starting current 2: Holding current

    2

    Red (+)

    Black (–)

    LED

    1

    Power consumption is de-creased by 1/4 by reducing the wattage required to hold the valve in an energized state. (Effective energizing time is over 62 ms at 24 VDC.)

    With the above circuit, the current consumption when holding is re-duced to save energy. Please refer to the electric wave data to the right.• Please be careful not to reverse the

    polarity, since a diode to prevent the reversed current is not provided for the power saving circuit.

    • Please use caution regarding the allowable voltage fluctuation be-cause there is about a 0.5 volt drop due to the transistor. (For de-tails, refer to the solenoid specifications for the individual valve.)

    Coil

    Dio

    de

    Tim

    er c

    ircui

    t

    1 3

    (Ground)

    Type W

    With light/surge voltage suppressor (�U)� Non-polar type

    With surge voltage suppressor (�R)

    With light/surge voltage suppressor (�Z)� Standard type (with polarity)

    With light/surge voltage suppressor (�S)

    4

    3 1

    Type WA

    4

    1(+)

    3(-)

    Diode to prevent reverse current

    Diode to prevent reverse current

    4 (Type WA)

    3 (Type WA)

    4 (Type WA)

    3 (Type WA)

    4 (Type WA)

    3 (Type WA)

    4 (Type WA)

    3 (Type WA)

    1(+)

    3(-)

    1(-)(+)

    3(+)(-)

    Varistor

    1(-)(+)

    3(+)(-)

    Varistor

    Solenoid valve side pin wiring diagram

    1426

    Surge Voltage Suppressor

    Grommet, L/M Plug Connector

    � Standard type (with polarity)Surge voltage suppressor (�S)

    Caution

    Red (+)

    Black (–)

    Diode to prevent reverse current

    With light/surge voltage suppressor (�Z)

    Red (+)

    Black (–)

    Diode to prevent reverse current

    � Non-polar typeWith surge voltage suppressor (�R)

    With light/surge voltage suppressor (�U)

    (–) (+)

    (+) (–)

    Varistor

    (–) (+)

    (+) (–)

    Varistor

    Coil

    Coil

    Coil

    Coil

    With surge voltage suppressor (DS)

    With light/surge voltage suppressor (DZ)

    Var

    isto

    rV

    aris

    tor

    Coil

    Coil

    DIN Terminal

    Coil

    Coil Coil

    Coil

    • For the standard type, connect + to 1 and – to 3 for Type W according to polarity, while + to 4 and – to 3 for Type WA.

    • Please be careful not to reverse the polarity, since a diode to prevent the reversed current is not provided for DC voltages other than 24 and 12 VDC.

    • Please use caution regarding the allowable voltage fluctuation because there is about a 1 volt drop for a valve with polarity protection. (For details, refer to the solenoid specifications for the individual valve.)

    • The WA-type valve cannot be grounded.

    M8 Connector

    Series SYJ300/500/700Specific Product Precautions 3Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1426

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • Grommet, L/M Plug Connector

    With light (�Z)

    DIN Terminal

    With light (DZ)

    (There is no “S” type because the generation of surge voltage is prevented by a rectifier.)

    Note) Surge voltage suppressor of varistor has residual voltage corresponding to the protective element and rated voltage; therefore, protect the controller side from the surge. The residual voltage of the diode is approximately 1 V.

    Surge Voltage Suppressor

    A type Y DIN connector is a DIN connector conforming to the 8-mm standard pitch between DIN terminals.

    DIN Terminal Type Y

    Solenoid Valve Mounting

    · Since a type D DIN connector has a 9.4-mm pitch between DIN terminals, it is not interchangeable.

    · Type D DIN connectors have the “N” indication at the end of rated voltage symbol. (For DIN connectors without lights, “N” is not indicated. Please refer to the name plate to distinguish.)

    · Dimensions are the same as type D DIN connector.· When replacing only the pilot valve assembly, V115-�D is

    interchangeable with V115-�Y. Do not replace V111 (G, H, L, M, W) to V115-�Y (DIN terminal), or vice versa.

    4. Secure the cord by fastening the ground nut.

    Changing the entry directionAfter separating the terminal block and housing, the cord entry can be changed by attaching the housing in the desired direction (4 directions at 90° intervals).∗ When equipped with a light, be careful not to damage the light

    with the cord’s lead wires.

    Compatible cable

    Precautions Plug in and pull out the connector vertically without tilting to one side.

    Cord O.D.: ø3.5 to ø7(Reference) 0.5 mm2, 2-core or 3-core, equivalent to JIS C 3306

    Ground nuttightening torque1.65 to 2.5 N �m

    Washer

    Grommet (Rubber)

    (Rating symbol)Refer to front matter 7.

    Terminal screw(3 locations)Tightening torque0.2 to 0.25 N �m

    Set screwTightening torque0.4 N �m

    Housing

    (Light mountinglocation)Terminal block

    Notch

    Mount it so that there is no slippage or deformation in gaskets, and tighten with the tightening torque as shown below.

    Caution

    ModelSYJ300SYJ500SYJ700

    Thread sizeM1.7M2.5M3

    Tightening torque0.12 N �m0.45 N �m0.8 N �m

    1427

    Caution

    Caution

    Coil

    Var

    isto

    r

    Var

    isto

    r

    Coil

    NL: Neon light

    Connection 1. Loosen the holding screw and pull the connector out of the

    solenoid valve terminal block.2. After removing the holding screw, insert a flat head screwdriv-

    er, etc. into the notch on the bottom of the terminal block and pry it open, separating the terminal block and the housing.

    3. Loosen the terminal screws (slotted screws) on the terminal block, insert the cores of the lead wires into the terminals ac-cording to the connection method, and fasten them securely with the terminal screws.

    Caution

    Caution

    How to Use DIN Terminal

    How to Use DIN Terminal

    When making connections, take note that using other than the supported size (ø3.5 to ø7) heavy duty cord will not satisfy IP65 (enclosure) standards. Also, be sure to tighten the ground nut and holding screw within their specified torque ranges.

    Caution

    Series SYJ300/500/700Specific Product Precautions 4Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.

    SYJ

    VQZ

    VP

    VG

    VP3�

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1427

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • Circuit Diagram with Light

    Rated voltage24 VDC12 VDC100 VAC200 VAC110 VAC220 VAC

    Voltage symbol24 V12 V

    100 V200 V110 V220 V

    Part no.SY100-61-3-05SY100-61-3-06SY100-61-2-01SY100-61-2-02SY100-61-2-03SY100-61-2-04

    Without light SY100-61-1With light

    Rated voltageDC24 VDC12 V100 VAC200 VAC

    110 VAC(115 VAC)220 VAC(230 VAC)

    Voltage symbol24 VN12 VN

    100 VN200 VN110 VN220 VN

    Part no.SY100-82-3-05SY100-82-3-06SY100-82-2-01SY100-82-2-02SY100-82-2-03SY100-82-2-04

    Without light SY100-82-1With light

    AC circuit

    NL : Neon lightR : Resister

    LED : Light emitting diodeR : Resister

    DC circuit

    Connector assembly with dust proof protective cover.• Effective to prevention of short circuit failure due to the entry of

    foreign matter into the connector.• Chloroprene rubber for electrical use, which provides outstand-

    ing weather resistance and electrical insulation, is used for the cover material. However, do not allow contact with cutting oil, etc.

    • Simple and unencumbered appearance by adopting round-shaped cord.

    CautionConnector Assembly with Cover

    Nil

    101520253050

    300 mm

    1000 mm6 600 mm

    1500 mm2000 mm2500 mm3000 mm5000 mm

    Lead wire length

    SY100-68-AHow to Order

    Connector Assembly with Cover: Dimensions

    Red Black

    Gray

    (14.5) L

    (40)

    (10)(8)

    (8)

    (6.9

    )

    (ø4.

    1)

    Symbol for connector assembly with cover

    How to Order Enter the part number for a plug connector solenoid valve without connector together with the part number for a connector assem-bly with cover.Ex. 1) Lead wire length of 2000 mm

    SYJ312-5LOZ-M3 SY100-68-A-20

    Ex. 2) Lead wire length of 300 mm (standard) SYJ312-5LPZ-M3

    ∗ In this case, the part number for the connector assembly with cover is not required.

    1428

    CautionDIN Connector Part No.

    Series SYJ300/500/700Specific Product Precautions 5Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1428

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • 22 33.9

    14

    2. To order connector cable only

    357

    Electrical entry W1, WA1: Cable length 300 mm W2, WA2: Cable length 500 mmW3, WA3: Cable length 1000 mmW4, WA4: Cable length 2000 mm W7, WA7: Cable length 5000 mm

    SYJ

    13

    4

    33.9

    ø9

    L 35 10

    Note) Connector cable should be mounted in the correct direction. Make sure that the arrow symbol on the connector is facing the triangle symbol on the valve when using SMC connector cable (V100-49-1-�). Be careful not to squeeze it in the wrong direction, as problems such as pin damage may occur.

    M8 Connector

    1. M8 connector types have an IP65 (enclosure) rating, offering protection from dust and water. However please note: these products are not intended for use in water.Select a SMC connector cable (V100-49-1-�) or a FA sensor type connector, with M8 threaded 3 pin specifications conforming to Nippon Electric Control Equipment Association Standard, NECA4202 (IEC60947-5-2). Make sure the connector O.D. is 10.5 mm or less when used with the Series SYJ300 manifold. If more than 10.5 mm, it cannot be mounted due to the size.

    2. Do not use a tool to mount the connector, as this may cause damage. Only tighten by hand. (0.4 to 0.6 N�m)

    3. The excessive stress on the cable connector will not be able to satisfy the IP65 rating. Please use caution and do not apply a stress of 30 N or greater.

    Failure to meet IP65 performance may result if using alternative connectors than those shown above, or when insufficiently tight-ened.

    Caution

    Caution

    • Connector cable mounting

    Arrow mark

    Triangle mark

    � Connector cable� Connector cable for M8 can be ordered as follows:

    1. To order solenoid valve and connector cable at the same time. (Connector cable will be included in the shipment of the solenoid valve.)

    How to Order

    Ex. 1) Cable length: 300 mmSYJ312-5W1ZE-M3

    Symbol for electrical entry

    Connector dimensions

    Brown: 1 Blue: 3

    Black: 4

    Cable length (L)

    500 mm1000 mm2000 mm5000 mm

    Part no.

    V100-49-1-2300 mm V100-49-1-1

    V100-49-1-3V100-49-1-4V100-49-1-7

    1429

    Series SYJ300/500/700Specific Product Precautions 6Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.

    SYJ

    VQZ

    VP

    VG

    VP3�

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1429

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

  • A B+-

    A B+-

    1430

    Pilot valves in this series are improved to provide excellent energy saving results. However following this improvement, these new valves are no longer compatible with the conventional pilot valve used at the interface. Consult with SMC when you need to exchange these pilot valves, in the case of manual override (marked in orange) of the adapter plate.

    Replacement of Pilot Valve

    Caution

    New type

    Conventional type

    (Orange)

    Manual override

    (Blue)Manual override

    Interface

    Pilot valve (V111) Adapter plate

    Interface

    Pilot valve (SY114) Adapter plate

    Series SYJ300/500/700Specific Product Precautions 7Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.

    P1369-P1430-E.qxd 08.9.2 3:27 PM Page 1430

    Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

    3 Port Solenoid Valve (Rubber Seal)Series VariationsManifold VariationsSeries SYJ700 3 Port Pilot Solenoid ValveManifold Specifications

    Series SYJ300/500/700 Made to OrderSeries SYJ500/700 Made to OrderSpecific Product Precautions