3 ncbz4p 100-315bc-18.5kw
DESCRIPTION
pumpTRANSCRIPT
-
Manf redini, Ezio
SAER Elettropompe spa
Rev ision no
2014-03-27
Company nameRespons. DepartmentPerson in chargePhone numberFax noE-mail address
1
Project Project ID Last updateCreated by Created on
Page:
Receiver From
Product description
Item Quant. Description
1 SERIES NCBZ1 END-SUCTION CENTRIFUGAL ELECTRIC PUMP-1450 1/min
NCBZ 4P-100-315 B (296)USESRecircling plants, heating, air conditioning, heat recov ery , plants of water supply procurement,pressurising units and f ire-f ighting sy stems.CONSTRUCTIVE CHARACTERISTICSNCBZ: complete set with bareshaf t end-suction centrif ugal pumps coupled with electric motor,on a baseThe motor unit and the rotating part of the pump can be taken away without remov ing the pumpbody f rom the sy stem piping.Hy draulics: pump body with dimension and perf ormances according to EN 733 rules, closedimpeller dy namically balanced and with balance holes f or the balancing of the axial thrust. Shaf tcompletely in stainless steel.IMPELLERImpeller material:Bronze G-CuSn10Impeller diameter: 295,99 mm FLANGESTYPE : UNI EN 1092-2- Outlet : DN 100- Inlet : DN 125Flanges (UNI EN 1092-2): up to DN 150: PN16, f rom DN 200: PN10. INPUT DATAQ=46 l/sH=25 m OUTPUT DATA AT 1450 1/minQ=46 l/s - Qmax=69,792 l/sH=25 m Absorbed power - duty point P2=16,1 kWMax absorbed power P2max=18,421 kWTemperature of the pumped liquid: f rom -15C up to +90C (upon request up to +120C)Max operation pressure (max allowed pressure in consideration of the sum of max. suctionpressure and of the head with null f low rate): PN10 (upon request PN16)Max env ironment temperature: 40C (f or higher temperature, please, v erif y ). MOTOR18,5 kW -400 V-50 Hz-3~Insulation class:: F - Protection: IP 55Poles n.: 4 INSTALLATION AND OPERATION CHARACTERISTICSThe NCB pumps can be positioned with horizontal, sloping or v ertical axis alway s with themotor upwards (please, v erif y with our technical dep.). The operating characteristics of thecatalogue and label are to be understood f or continuous serv ice and with clear water (specif icweight = 1000 kg/m3) with a max manometric suction height of approximately 1,5 m. For highermanometric heights and up to a max of approximately 6 m, the characteristics decrease in thev arious deliv ery data. ACCESSORIES ON REQUESTKit counterf langes PERFORMANCE TOLERANCESPumps: UNI EN ISO 9906 Appendix A, lev el 1 on request.Motor: IEC 60034-1 rules.
1 Bearing bracket: Grease bearing1 Shaft seal: BVEG (Gra/AlO/EPDM)1 Material design: BVEG (Graphite/Allumina Oxide/EPDM)1 Seal f ace: Carbon graphite resin impreg.
SAER Elettropompe spa - V.Circonvallazione, 22 - 42016 Guastalla (RE) Italy - tel.+390522830941 - fax +390522826948 - www.saerelettropompe.com - Modification without advise!
NCBZ 4P-100-315 B (296)
-
Manf redini, Ezio
SAER Elettropompe spa
Rev ision no
2014-03-27
Company nameRespons. DepartmentPerson in chargePhone numberFax noE-mail address
2
Project Project ID Last updateCreated by Created on
Page:
Receiver From
Product description
Item Quant. Description
1 Seat: Alumina Oxide1 Rubber elements: EPDM Rubber1 Spring and metal bellows: Stainless steel AISI 316
Subtotal:
Total price excl. VAT VAT in % Total price incl. VAT160,00 Euro 0,00 Euro
SAER Elettropompe spa - V.Circonvallazione, 22 - 42016 Guastalla (RE) Italy - tel.+390522830941 - fax +390522826948 - www.saerelettropompe.com - Modification without advise!
NCBZ 4P-100-315 B (296)
-
Manf redini, Ezio
SAER Elettropompe spa
Receiver
Rev ision no
2014-03-27
From
Company nameRespons. DepartmentPerson in chargePhone numberFax noE-mail address
3
Project Project ID Last updateCreated by Created on
Page:Technical data
FluidOperating temperature t A
Density at t A
Kin. v iscosity at t A
Nominal f low
Nominal head
Static head
Inlet pressure
NPSH - v alue of plant
C
kg/dm
mm/s
Operating data specificationl/s
m
m
bar
m
Impeller ty pe
Pump name
Size
Design
Speed
Max. working pressure
Nominal
Max-
Min-
Flow
No of stages
Nominal
Max-
Min-
Head
Head H(Q=0)
NPSH 3%
Pump
Shaf t power
Ef f iciency
NCBZ 4P-100-315 B (296)
1
69,8
16,7
25
18,5
28,4
46
16,1
69,9
1/min
bar
l/s
l/s
l/s
m
m
m
kW
%
28,5m
2,65
Materials Pump
Shaf t
Impeller
Pump body
Seal disc
Gasket
Seal f ace
Seat
Rubber elements
Spring and metal bellows
Stainless steel AISI 431 (1.4057)
Bronze G-CuSn10
Spheroidal Cast iron EN-GJS-500
Spheroidal Cast iron EN-GJS-500
Natural f iber
Carbon graphite resin impreg.
Alumina Oxide
EPDM Rubber
Stainless steel AISI 316
Remarks:
m
NCBZ 4P-100-315 B (296)
Water, pure
46
25
0
20
0,9983
0
0,09793
1,005
125/100/315
1450
2,89
Motor
Manuf acturer / Ty pe
14501/min
Rated power kW 18,5
Speed
Electric v oltage V 400 V
Electric current A
IP 55Degree of protection
180 M 4 - 18,5
Frame size 180 M
a 140b1 400b2 450b3 500e 137f 470H 330h1 80h2 315l1 1200l2 1100l3 50S M16x 4
Dimensions in mm
Head
Shaft power P2
Efficiency
NPSH-values
B (296)
70,5%
Application range
25 m
16,1 kW
69,9 %
2,65 m
46 l/s
B (296) (P2)
25 m
16,1 kW
69,9 %
2,65 m
46 l/s
B (296)
25 m
16,1 kW
69,9 %
2,65 m
46 l/s
B (296)
25 m
16,1 kW
69,9 %
2,65 m
46 l/s
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
[m]
8
12
[kW]
404550556065[%]
2
2,5
3
3,5
[m]
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 [l/s]
1
Insulation class F
Starting mode Unknown
18,422kWMax absorbed power
Mech. seal EN 12756
SAER
C 158D 220DN 100K 180n 8n 19
C 188D 250DN 125K 210n 8n 19
50Hz3~
UN
I EN
ISO
990
6-A
SAER Elettropompe spa - V.Circonvallazione, 22 - 42016 Guastalla (RE) Italy - tel.+390522830941 - fax +390522826948 - www.saerelettropompe.com - Modification without advise!
Ef f iciency 4/4 0 %
-
Manf redini, Ezio
SAER Elettropompe spa
Rev ision no
2014-03-27
Company nameRespons. DepartmentPerson in chargePhone numberFax noE-mail address
4
Project Project ID Last updateCreated by Created on
Page:
FromReceiver
Perf ormance data based to:
Performance curves
Head
Shaft power P2
Efficiency
NPSH-values
B (296)
70,5%
Application range
25 m
16,1 kW
69,9 %
2,65 m
46 l/s
B (296) (P2)
25 m
16,1 kW
69,9 %
2,65 m
46 l/s
B (296)
25 m
16,1 kW
69,9 %
2,65 m
46 l/s
B (296)
25 m
16,1 kW
69,9 %
2,65 m
46 l/s
12,513
13,514
14,515
15,516
16,517
17,518
18,519
19,520
20,521
21,522
22,523
23,524
24,525
25,526
26,527
27,528
28,529[m]
8
10
12
14
16
[kW]
4044485256606468
[%]
2
2,4
2,8
3,2
3,6
[m]
0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 [l/s]
1
Min.
Flow
Max.
16,7
l/s l/s
69,8
Operating area
hMax.
l/s
53,1
Head
m
H(Q=0)
28,5
h
mMax.
23,4
Shaf t power P2P2(Q=0)
kW
Max.
kW
18,4
hMax.kW
17,2
Impeller ty pe
Frequency 50 HzHz
Speed 14501/min
Impeller construction
Sense of rotation
Outlet width
Closed
Clockwise f rom the driv e end
Flow
Operating data specif ication
Pump data
25
46 25
NCBZ 4P-100-315 B (296)
Water, pure [100%] ; 20C; 0,998kg/dm; 1mm/s
DN 100
Head
46 l/s
l/s
m
m
UNI EN ISO 9906:2012 - Grade 3B
SAER Elettropompe spa - V.Circonvallazione, 22 - 42016 Guastalla (RE) Italy - tel.+390522830941 - fax +390522826948 - www.saerelettropompe.com - Modification without advise!
-
Manf redini, Ezio
SAER Elettropompe spa
Rev ision no
2014-03-27
Company nameRespons. DepartmentPerson in chargePhone numberFax noE-mail address
5
Project Project ID Last updateCreated by Created on
Page:
Spare partsNCBZ 4P-100-315 B (296)
SAER Elettropompe spa - V.Circonvallazione, 22 - 42016 Guastalla (RE) Italy - tel.+390522830941 - fax +390522826948 - www.saerelettropompe.com - Modification without advise!