    SR.NO

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    DATA SHEET DATA SHEET NO SHEET

    EID/130/DS/02

    327, TTC industrial area,MERCURY CALIBRATOR

    ITEM CODE

    Pawane, Navi Mumbai 81I-BNNNCA

    roducedorexhibitedtothirdpartieswithoutanywrittenpermissionofTFS

    DESCRIPTION SPECIFICATION

    MANUFACTURER THERMO FISHER SCIENTIFIC, USA

    MODEL NO 81i-BNNNCA

    DISPLAY LCD

    MASS FLOW MEASUREMENT ACCURACY +/- 2% SET POINT OR +/- 1% FS, WHICHEVER IS LESS FROM

    -20 TO 100% FS

    REPEATABILITY OF MASS FLOW CONTROL +/- 2% OF READING OR 1% OF FULL SCALE, WHICHEVER IS LESS

    -20 TO 100% FS

    LINEARITY OF MASS FLOW MEASUREMENTS +/- 0.5% FS

    ZERO AIR FLOW CONTROLLER 20 SLM

    SPAN GAS FLOW CONTROLLER 50 SCCM

    HG SOURCE CONTROLLER 0- 15C

    HG CONCENTRATION STD OUTPUT 3 - 50 g/dscm

    LINEARITY +/- 2% FS

    OPERATING TEMPERATURE 5- 40C

    POWER REQUIREMENT 220 VAC 50HZ 250W

    SIGNAL OUTPUT ANALOG OUT (4-20mA)

    15

    16

    17

    18

    NOTE :

    10/20/2011 0 SS MNS SIEMENS

    ThisdocumentisthepropertyofThermoFisherScientificIndiaPvtLtd.andnottobecopiedorrepr

    MOUNTING TYPE ON 19 RACK

    16.75(W) X 8.62(H) X 23(D)PHYSICAL DIMENSIONS

    APPROXIMATE WEIGHT 21.8 KG

    MODEL DE-CODIFICATION

    81I MERCURY CALIBRATOR

    B = 220 VAC 50/60 Hz

    N = HYDRATOR (STANDARD)

    N = NOT AVAILABLE YET (FUTURE OPTION)

    N = NOT AVAILABLE YET (FUTURE OPTION)

    C = 6 CHANNEL 4-20mA CURRENT OUTPUT, (STANDARD)

    A = BENCH MOUNTING (STANDARD)

    ISSUED FOR APPROVAL

    DATE REV PREPARED CHECKED APPROVEDDESCRIPTION

  • 8/10/2019 27.Hg Calibrator 81i Spec

    2/3

    The Thermo Scientific Mercury Calibrator,

    Model 81iMercury Calibrator is one of

    the four major components of the Mercury

    Freedom System. The Model 81iutilizes

    a vapor generator that allows standard

    calibration and dynamic spiking into the

    extraction probe. A wide calibration range

    lets you directly calibrate the analyzer at

    post-dilution concentrations. The calibrator

    is ideally suited for daily zero/span checks

    and routine converter efficiency and

    linearity testing.

    Designed to meet the provisions of 40CFR

    Parts 60 and 75, the Mercury Freedom

    System provides a complete mercury

    monitoring solution that reports elemental,

    ionic, and total mercury in exhaust stacks

    from both coal-fired boilers and waste

    incinerators.

    The Model 81ialso offers the benefit

    the iSeries platform features flexible

    communications, increased serviceab

    and an easier to use interface.

    Ethernet connectivity provides efficien

    remote access, allowing the user to

    download measurement information d

    from the instrument without having to

    on site. Captive hardware and slide-a

    modules allows easy access for servic

    periodic maintenance.

    You can easily program short-cut keys

    allow you to jump directly to frequent

    accessed functions, menus or screens

    The larger interface screen can displa

    to five lines of measurement informat

    while the primary reporting screen rem

    visible.

    Key Features

    Performs standard calibration upstream of the

    inertial filter

    Capability to perform diagnostic calibrations

    directly to analyzer and critical orifice

    Long lasting Hg source

    Uses Peltier cooler vapor pressure control

    and mass flow control

    Wide concentration range for post-dilution

    calibration

    Ideal for periodic converter efficiency and

    linearity testing

    p

    Mercury Calibrator, Model 81iPrecision source of mercury for automated calibrations and checks

  • 8/10/2019 27.Hg Calibrator 81i Spec

    3/3

    Gas Dilution:

    Accuracy of each mass flow measurement +2% of reading or 1% of full scale, whichever is less - 20 to 100% full scaleLinearity of mass flow measurement 0.5% of full scale

    Repeatability of mass flow measurement +2% of reading or 1% of full scale, whichever is less - 20 to 100% full scaleMass Flow Controller:

    Zero Air Flow Controller 20 slmSpan Gas Flow Controller 50 sccmHg Source Control 0O- 15OCHg Concentration Standard Output 3 - 50 g/dscmLinearity +/- 2 % full scale

    Operating Temperature 5O- 40OC

    Power Requirements 250 wattsSize and Weight 16.75"(W) x 8.62"(H) x 23"(D), 48 lbs. 425 mm (W) x 219 mm (H) x 584 mm (D), 21.8 kg

    Outputs Selectable Voltage, RS232/RS485, TCP/IP, 10 Status Relays, and Power FailIndication (standard). 0-20 or 4-20 mA Isolated Current Output (optional)

    Inputs 16 Digital Inputs (standard), 8 0-10 VAC, Analog Inputs (optional)

    CDA(20-40 psig)

    Bypasssolenoid

    Hg source

    Hg scrubberExhaust

    MFC 10-50 sccm

    MFC 20-20 lpm Zero airto analyzer

    Calibration gas

    to analyzer

    Cal gas to probeZero air to probe

    RegulatorSet to 25 psig

    NO

    NC

    C V5

    NO

    NCCNCC

    Tempcontrol

    V1

    V2

    V3

    V4

    C

    C

    NC

    NCNO

    NO

    Model 81i Hg Calibrator

    Hg Calibrator, Model 81i

    To maintain optimal product performance, you need immediate access to experts worldwide, as well as priority status when your air quality equipme

    needs repair or replacement. We offer comprehensive, flexible support solutions for all phases of the product life cycle. Through predictable, fixed-co

    pricing, our services help protect the return on investment and total cost of ownership of your Thermo Scientific air quality products.

    Product Specifications

    Environmental

    Instruments Division

    Air Quality Instruments

    This specification sheet is for informational purposes only and is subject to change without notice. Thermo Fisher Scientific makes no warranties, expressed or implied, in this product summary.

    2009 Thermo Fisher Scientific, Inc. All rights reserved Thermo Fisher Scientific, Inc.

    This product is manufactured in a plant whose quality management system is ISO 9001 certified.

    Lit_Model#AQI_01/09