    MTNAlarm HandlingGuidelineUsing Moshell CommandsMaria Riordan7/21/2010

    ContentsINTRODUCTION:................................................................................................................................................................ 4ANTENNA/ASC/RET:.......................................................................................................................................................... 5AuxPlugInUnit_CommunicationLostWithAsc:............................................................................................................... 5AuxPlugInUnit_CommunicationLostWithRet:............................................................................................................... 5TmaDevice_LnaDegraded: .........................................................

    ................................................................................... 5TmaDevice_LnaFailure: ................................................................................................................................................. 6RetDeviceSet_RetFailure: ............................................................................................................................................. 6RetDevice_RetFailure:................................................................................................................................................... 6RetDevice_ElectricalAntennaTiltOutOfRange:.............................................................................................................. 7

    AscDeviceGroup_GeneralHWError:.............................................................................................................................. 7AntennaBranch_AntennaProblemInBranchA: .............................................................................................................. 7AntennaBranch_AntennaProblemInBranchB: .............................................................................................................. 8AntennaBranch_FeederCurrentTooLowInBranchA ...................................................................................................... 9AntennaBranch_FeederCurrentTooLowInBranchB ...................................................................................................... 9AntennaBranch_FeederCurrentTooHighInBranchA ................................................................................................... 10AntennaBranch_FeederCurrentTooHighInBranchB.....................................

    ............................................................... 10PLUG IN UNIT: ................................................................................................................................................................. 12FcuDeviceGroup_NumberOfHwEntitiesMismatch: .................................................................................................... 12FanDeviceGroup_LeftFanSpeedTooLow:.................................................................................................................... 12AuxPlugInUnit_PiuConnectionLost: ............................................................................................................................ 13

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    2/36

    TpaDevice_AmplificationError .................................................................................................................................... 13RuDeviceGroup_GammaUplinkFailure: ...................................................................................................................... 13Plug-In Unit General Problem..................................................................................................................................... 14RaxDeviceGroup_GeneralSwError: ............................................................................................................................. 14TxDeviceGroup_GeneralSwError: ............................................................................................................................... 14RaxDeviceGroup_GeneralHwError: ............................................................................................................................ 15LICENSE ISSUES: .............................................................................................................................................................. 16License Key File Fault: ................................................................................................................................................. 16NodeBFunction_16QamLicenseNotValid:................................................................................................................... 16

    Password File Fault: .................................................................................................................................................... 16UpLinkBaseBandPool_ULHWLessThanULCapacity: .................................................................................................... 17DownLinkBaseBandPool_DLHWLessThanDLCapacity:................................................................................................ 17NodeBFunction_DlHwUsageExceedsDlLicenseLevel: ................................................................................................. 17NodeBFunction_UlHwUsageExceedsUlLicenseLevel: ................................................................................................. 18TRANSMISSION: ..................................................................................................................................................

    ............ 20Loss of Tracking:...............................................................

    ................................................................................

    ........... 20Loss of Synch Reference Redundancy:........................................................................................................................ 20PDH Loss of Signal: ...................................................................................................................................................... 20PDH Loss of Frame: ..................................................................................................................................................... 21Loss of Cell Delineation on IMA Link:...........................................

    ...............................................................................21Remote Defect Indication on IMA Link: ...................................................................................................................... 22IMA Link Reception Unusable at Far End:................................................................................................................... 22IMA Link Reception Misconnected: ............................................................................................................................ 23IMA Group Insufficient Links:...................................................

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    3/36

    ................................................................................

    ... 23IMA Group Insufficient Links at Far End: .................................................................................................................... 24Heartbeat Failure: ....................................................................................................................................................... 25MISCELLANEOUS: ............................................................................................................................................................ 27Carrier_RejectSignalFromHardware ........................................................................................................................... 27NbapCommon_Layer3SetupFailure:........................................................................................................................... 27RNC:................................................................................................................................................................................. 29UtranCell_NbapReconfigurationFailure:..................................................................................................................... 29NbapDedicated_RncRbsControlLinkDown: ................................................................................................................ 29UtranCell_ServiceUnavailable:...................................................................................................................................

    . 30UtranCell_ExternalResourceUnavailable: .........................................

    .......................................................................... 30UtranCell_NbapMessageFailure: ................................................................................................................................ 31EXTRA NOTES: ................................................................................................................................................................. 32MTN Configuration Types ........................................................................................................................................... 32RBS 3202 .......................................................................

    .............................................................................................. 32SMOKE Text Analysis................................................................................................................................................... 32Node B Restart Procedure .......................................................................................................................................... 32License Issues on Node B............................................................................................................................................ 32USEFUL Commands: ...............................................................................................................................................

    ......... 33Checking Performance: ............................................................................................................................................... 33Locking and Unlocking site on RNC:............................................................................................................................ 33Miscellaneous: ............................................................................................................................................................ 33

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    4/36

    INTRODUCTION:

    This alarm guide is to help assist in clearing alarms on the RNC and RBS using MOSHELL commands.Not all cases will be the same. A few things to note for all alarms are as follows:

    1) Ensure that there are no existing REFS open for the site either with SMC orBSS.

    2) Refer to the ALEX Documentation. This will give you a full and clear understanding of the alarmyou are dealing with.

    3) Acknowledge the alarm in the OSS Alarm List Viewer.

    4) Check all associated alarms on RNC and RBS. Check the history of the alarm taking note if it is are-occurring alarm. (lga | grep )

    5) Use the guidelines below to clear the alarm.

    6) Once alarm has been cleared confirm the site is carrying traffic as normal.

    ANTENNA/ASC/RET:AuxPlugInUnit_CommunicationLostWithAsc:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->CommunicationLostWithAsc

    This alarm will generally require an RE to go to site. Communication with the ASC/RET is lost. The consequence of thisalarm is that planning/optimisation will be unable to make a tilt change to theaffected sector. Connection with the ASCwill need to be restored on site or a replacement ASC will be needed.

    If the alarm is inter-failing or re-occurring, the best solution is to swap outthe ASC.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmslga | grep AuxPlugInUnit_CommunicationLostWithAsc *show history of current alarmget radio no *confirm if node is carrying trafficst plug *print state of all plug in unitsget xxx *do a get on the disabled proxy numberacl xxx *check what action you can perform on the proxy number

    acc xxx restartAuxUnit *try restart the ASC/RET using the proxy number

    RNC:moshell XXRNCX *log onto the RNClt all *load all Managed Objectsalt *show current alarmslst .xxxx *show status of channels

    AuxPlugInUnit_CommunicationLostWithRet:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    5/36

    CommunicationLostWithRet

    This alarm will generally require an RE to go to site. Communication with the ASC/RET is lost. The consequence of thisalarm is that planning/optimisation will be unable to make a tilt change to theaffected sector. Connection with the RETwill need to be restored on site or a replacement ASC will be needed.

    If the alarm is inter-failing or re-occurring, the best solution is to swap outthe RET.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmslga | grep AuxPlugInUnit_CommunicationLostWithRet *show history of current alarmget radio no *confirm if node is carrying trafficst plug *print state of all plug in unitsget xxx *do a get on the disabled proxy numberacl xxx *check what action you can perform on the proxy numberacc xxx restartAuxUnit *try restart the ASC/RET using the proxy number

    RNC:

    moshell XXRNCX *log onto the RNClt all *load all Managed Objectsalt *show current alarmslst .xxxx *show status of channelsTmaDevice_LnaDegraded:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->LnaDegraded

    This alarm is issued by the TmaDevice Managed Object (MO) when one of the two transistors amplifying the RF signals inthe Antenna System Controller (ASC) or the AISG/3GPP Tower Mounted Amplifier (ATMA) fails. It indicates that the LNAgain in one of the branches on the ASC has degraded. The UL signal will pass, bu

    t with decreased level.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms and confirm what sector is affectedst plug *print state of all plug in unitslpr SectorAntenna=x,AuxPlugInUnit=x *shows associated equipment with the ASCacl xxx *check what action you can perform on the ASCacc xxx restartAuxUnit *try restart the ASC/RET using the proxy number

    If the alarm does not clear after restarting the ASC an RE will be required to v

    isit the site and replace the ASC.TmaDevice_LnaFailure:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->LnaFailure

    The fault is located in the Low Noise Amplifier (LNA), which amplifies the RF signals in the receiver (RX) chain. When thetransistors in one branch have failed, the cell is able to carry traffic as longas the other branch works, but the RX chainperformance is degraded. The LNA gain in one of the branches in the ASC is lost.

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    6/36

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms and confirm what sector is affectedst plug *print state of all plug in unitslpr SectorAntenna=x,AuxPlugInUnit=x *shows associated equipment with the ASCget xxx *use this to show more information about the plug in unitacl xxx *check what action you can perform on the ASCacc xxx restartAuxUnit *try restart the ASC/RET using the proxy number

    If the alarm does not clear after restarting the ASC an RE will be required to visit the site and replace the ASC.

    RetDeviceSet_RetFailure:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->RetFailureThis alarm is issued by the RetDevice or RetDeviceSet Managed Objects (MO) whenthe Remote Electrical Tilt Unit (RETU)malfunctions. The RETU is used to tilt the antenna according to the specified antenna tilt configuration parameters in theRET profile.The causes of the alarm are:

    A faulty RETUThe RETU arm is unable to move for environmental reasons, for example, antennaicingAntenna and RETU not installed

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms and confirm what sector is affectedlpr SectorAntenna=x,AuxPlugInUnit=2get xxx *using the proxy number from the above command will show the state of the RetDeviceSetacl xxx *check what action you can perform on the proxy number

    acc xxx restartAuxUnit *try restart the RET using the proxy number

    If a restart does not clear the alarm an RE will need to go to site and check/replace the RET unit.

    RetDevice_RetFailure:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->RetFailureThis alarm is issued by the RetDevice or RetDeviceSet Managed Objects (MO) whenthe Remote Electrical Tilt Unit (RETU)malfunctions. The RETU is used to tilt the antenna according to the specified antenna tilt configuration parameters in theRET profile.

    The causes of the alarm are:A faulty RETUThe RETU arm is unable to move for environmental reasons, for example, antenna

    icingAntenna and RETU not installed

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms and confirm what sector is affected

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    7/36

    lpr SectorAntenna=x,AuxPlugInUnit=2get xxx *using the proxy number from the above command will show the state of the RetDeviceSetacl xxx *check what action you can perform on the proxy numberacc xxx restartAuxUnit *try restart the RET using the proxy number

    If a restart does not clear the alarm an RE will need to go to site and check/replace the RET unit.RetDevice_ElectricalAntennaTiltOutOfRange:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->ElectricalAntennaTiltOutOfRangeThis alarm is issued by the RetDevice Managed Object when the electrical antennatilt is out of range. The electrical tilt onthe site is set to a value that the RET and antenna does not support.RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms and confirm what sector is affectedget ret elec *shows the current electrical tilt settings on the sectorsget retdevice tilt *shows the max and min tilt supported by the ret devicelpr SectorAntenna=x,AuxPlugInUnit=2get xxx *using the proxy number from the above command will show the state of the RetDeviceSetacl xxx *check what action you can perform on the proxy number

    acc xxx restartAuxUnit *try restart the RET using the proxy number

    If restarting the RET does not clear the alarm confirm with Planning/Optimisation that the Antenna Type is correct:get sector antennatype *shows the antenna type for each sectorIf the alarm still persists an RE will need to go to site and check/replace theRET Unit.AscDeviceGroup_GeneralHWError:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->GeneralHWError

    This alarm is issued by the ASC. It indicates that the ASC is faulty and needs to be restarted or replaced.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms and confirm what sector is affectedlpr SectorAntenna=x,AuxPlugInUnit=1acl xxx *check what action you can perform on the proxy numberacc xxx restartAuxUnit *try restart the ASC using the proxy number

    If the alarm does not clear after restarting the ASC an RE will need to go to site and investigate/replace the ASC.AntennaBranch_AntennaProblemInBranchA:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->

    AntennaProblemInBranchA

    This alarm is issued by the AntennaBranch Managed Object (MO) when one of the following units is faulty or a cable isfaulty or disconnected:- ASC- Antenna Jumper Cable

    RBS:moshell Uxxxx *log onto the node

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    8/36

    lt all *load all Managed Objectsalt *show current alarms and confirm what sector is affectedlga | grep AntennaBranch_AntennaProblemInBranchA *shows history of alarmst plug *check the current status of the ASC/RETlst ret *check the current status of the ASC/RETlst asc *check the current status of the ASC/RETacl xxx *check what action you can perform on the ASC using the proxy numberacc xxx restartAuxUnit *try restart the ASC/RET

    NOTE:Equipment=1,SectorAntenna=x,AuxPlugInUnit=1 *ASCEquipment=1,SectorAntenna=x,AuxPlugInUnit=2 *RET

    cabx *get the port number of the ASC for the affected sector

    ===============================================================================================SMN APN PORT BOARD GREEN YELLOW RED PRODUCT NR===============================================================================================0 12 port_0_dev_4 RU21 steady 16hz off K

    RC 118 16/10 12 port_0_dev_4 FU12 ON 16Hz OFF K

    RC 118 17/10 12 port_1_dev_10 ASC steady 16hz off KRY 112 42/30 12 port_4_dev_5 RU21 steady 16hz off K

    RC 118 16/10 12 port_4_dev_5 FU12 ON 16Hz OFF K

    RC 118 17/10 12 port_5_dev_12 ASC steady 16hz off K

    RY 112 42/30 12 port_8_dev_6 RU21 steady 16hz off K

    RC 118 16/10 12 port_8_dev_6 FU12 ON 16Hz OFF K

    RC 118 17/1

    0 12 port_9_dev_14 ASC steady 16hz off KRY 112 42/3-----------------------------------------------------------------------------------------------

    lhsh 001200/port_1_dev_10 asc vswr *prints the VSWR value for the Antenna Branchlh asc asc vswr *command to show VSWR for all sectors

    If the above commands don't work try:lh asc dbg vswr 0 get -k

    This command gives you the return loss value which can be converted to the desir

    ed VSWR value using the following link:http://www.soontai.com/cal_rtvswr.html

    Acceptable value for VSWR should be < 1.5. If the value is higher than this an RE will need to go to site andinvestigate/sweep the affected Antenna Branch.AntennaBranch_AntennaProblemInBranchB:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->AntennaProblemInBranchB

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    9/36

    This alarm is issued by the AntennaBranch Managed Object (MO) when one of the following units is faulty or a cable isfaulty or disconnected:- ASC- Antenna Jumper Cable

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms and confirm what sector is affectedlga | grep AntennaBranch_AntennaProblemInBranchA *shows history of alarmst plug *check the current status of the ASC/RETlst ret *check the current status of the ASC/RETlst asc *check the current status of the ASC/RETacl xxx *check what action you can perform on the ASC using the proxy numberacc xxx restartAuxUnit *try restart the ASC/RET

    NOTE:Equipment=1,SectorAntenna=x,AuxPlugInUnit=1 *ASCEquipment=1,SectorAntenna=x,AuxPlugInUnit=2 *RET

    cabx *get the port number of the ASC for the affected sector

    ===============================================================================================SMN APN PORT BOARD GREEN YELLOW RED PRODUCT NR===============================================================================================0 12 port_0_dev_4 RU21 steady 16hz off K

    RC 118 16/10 12 port_0_dev_4 FU12 ON 16Hz OFF K

    RC 118 17/10 12 port_1_dev_10 ASC steady 16hz off K

    RY 112 42/30 12 port_4_dev_5 RU21 steady 16hz off K

    RC 118 16/10 12 port_4_dev_5 FU12 ON 16Hz OFF KRC 118 17/10 12 port_5_dev_12 ASC steady 16hz off K

    RY 112 42/30 12 port_8_dev_6 RU21 steady 16hz off K

    RC 118 16/10 12 port_8_dev_6 FU12 ON 16Hz OFF K

    RC 118 17/10 12 port_9_dev_14 ASC steady 16hz off K

    RY 112 42/3-----------------------------------------------------------------------------------------------

    lhsh 001200/port_1_dev_10 asc vswr *prints the VSWR value for the Antenna Branchlh asc asc vswr *command to show VSWR for all sectors

    If the above commands don't work try:lh asc dbg vswr 0 get -k

    This command gives you the return loss value which can be converted to the desired VSWR value using the following link:

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    10/36

    http://www.soontai.com/cal_rtvswr.html

    Acceptable value for VSWR should be < 1.5. If the value is higher than this an RE will need to go to site andinvestigate/sweep the affected Antenna Branch.AntennaBranch_FeederCurrentTooLowInBranchARBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->FeederCurrentTooLowInBranchAThis alarm is issued by the AntennaBranch Managed Object (MO) when one of the following units is faulty or a cable isfaulty or disconnected:- ASC- RET- Antenna Jumper Cable

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms and confirm what sector is affectedlga | grep AntennaBranch_FeederCurrentTooLowInBranchA *shows history of alarmst plug *check the current status of the ASClst ret *check the current status of the ASC/RETlst asc *check the current status of the ASC/RET if disabled RE will need to attend

    acl xxx *check what action you can perform on the ASC using the proxy numberacc xxx restartAuxUnit *try restart the ASC

    If no issues are seen with the ASC and the alarm still persists an RE will needto go to site and investigate any loose feederconnections.

    NOTE:Some other parameters to checkget antennabranch supervision *Value of 0 implies no Antenna Supervision.mom . antennaSupervisionThreshold *description of parameterAntennaBranch_FeederCurrentTooLowInBranchBRBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->

    FeederCurrentTooLowInBranchBThis alarm is issued by the AntennaBranch Managed Object (MO) when one of the following units is faulty or a cable isfaulty or disconnected:- ASC- RET- Antenna Jumper Cable

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms and confirm what sector is affectedlga | grep AntennaBranch_FeederCurrentTooLowInBranchA *shows history of alarm

    st plug *check the current status of the ASClst ret *check the current status of the ASC/RETlst asc *check the current status of the ASC/RET if disabled RE will need to attendacl xxx *check what action you can perform on the ASC using the proxy numberacc xxx restartAuxUnit *try restart the ASC

    If no issues are seen with the ASC and the alarm still persists an RE will needto go to site and investigate any loose feederconnections.

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    11/36

    NOTE:Some other parameters to checkget antennabranch supervision *Value of 0 implies no Antenna Supervision.mom . antennaSupervisionThreshold *description of parameterAntennaBranch_FeederCurrentTooHighInBranchARBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->FeederCurrentTooHighInBranchAThis alarm is issued by the AntennaBranch Managed Object (MO) when one of the following units is faulty or a cable isfaulty or disconnected:- ASC- RET- Antenna Jumper Cable

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms and confirm what sector is affectedlga | grep AntennaBranch_FeederCurrentTooLowInBranchA *shows history of alarmst plug *check the current status of the ASClst ret *check the current status of the ASC/RETlst asc *check the current status of the ASC/RET if disabled RE will need to attend

    acl xxx *check what action you can perform on the ASC using the proxy numberacc xxx restartAuxUnit *try restart the ASC

    If no issues are seen with the ASC and the alarm still persists an RE will needto go to site and investigate any loose feederconnections.

    NOTE:Some other parameters to checkget antennabranch supervision *Value of 0 implies no Antenna Supervision.mom . antennaSupervisionThreshold *description of parameterAntennaBranch_FeederCurrentTooHighInBranchBRBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->

    FeederCurrentTooHighInBranchBThis alarm is issued by the AntennaBranch Managed Object (MO) when one of the following units is faulty or a cable isfaulty or disconnected:- ASC- RET- Antenna Jumper Cable

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms and confirm what sector is affectedlga | grep AntennaBranch_FeederCurrentTooLowInBranchA *shows history of alarm

    st plug *check the current status of the ASClst ret *check the current status of the ASC/RETlst asc *check the current status of the ASC/RET if disabled RE will need to attendacl xxx *check what action you can perform on the ASC using the proxy numberacc xxx restartAuxUnit *try restart the ASC

    If no issues are seen with the ASC and the alarm still persists an RE will needto go to site and investigate any loose feederconnections.

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    12/36

    NOTE:Some other parameters to checkget antennabranch supervision *Value of 0 implies no Antenna Supervision.mom . antennaSupervisionThreshold *description of parameter

    PLUG IN UNIT:FcuDeviceGroup_NumberOfHwEntitiesMismatch:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->NumberOfHwEntitiesMismatch

    This alarm is issued by the FcuDeciceGroup MO when there are too few fans in operation. It could be the cause of a faultyor disconnected fan unit cable or too few fans installed on site.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmslpr AuxPlugInUnit=2,FcuDeviceGroup=1get xxx *using proxy number from above command will show the number of Fans defined on the siteget . numberoffangroups

    An RE will need to go to site and confirm that the number of Fans installed on site matches what is configured. Fan unitcables will also need to be checked.

    FcuDeviceGroup_FanFailure:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->FanFailure

    This alarm is issued by the FcuDevice Managed Object when there is a problem with one or more of the fanscontrolled by the Fan Control Unit

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmspr AuxPlugInUnit=2

    acl xxx *shows what action you can perform on the Fan Control Unit (FCU)acc xxx restartAuxUnit *restarts the FCUalt *confirm the alarm has cleared

    If the alarm does not clear after restarting the FCU and RE will need to attendon site.FanDeviceGroup_LeftFanSpeedTooLow:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->LeftFanSpeedTooLowThe LeftFanSpeedTooLow alarm indicates that there are faults in one or more of f

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    13/36

    ollowing units:BaseBand (BB) Subrack Fan UnitRadio Frequency (RF) Subrack Fan UnitMulti-Carrier Power Assembly (MCPA) Subrack Fan UnitPower Subrack (PS) Fan Unit

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmslga | grep FanDeviceGroup_LeftFanSpeedTooLow *show history of current alarmlpr Subrack=2,AuxPlugInUnit=1st plug *print state of all plug in unitsget xxx *using proxy number from above command will show the status of the FANcabx *shows the led status of the fan unitmom AuxPlugInUnit led *description of LED statusacl xxx *check what action you can perform on the proxy numberacc xxx restartAuxUnit *try restart the plug in unit

    A red LED showing a steady light indicates a faulty FAN. If the alarm does not clear after restarting the unit an RE isrequired to attend the site and replace the Fan UnitAuxPlugInUnit_PiuConnectionLost:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->PiuConnectionLost

    This alarm is issued by the AuxPlugInUnit Managed Object (MO) when communicationbetween one of the Auxiliary Units(AU) and its device is lost.Use ALEX to check what actions to perform on the various types of Plug In Units.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmslga | grep AuxPlugInUnit_PiuConnectionLost *show the history of the current alarm

    st plug *print state of all plug in unitslpr AuxPlugInUnit=x *shows associated equipment with plug in unitget xxx *use this to show more information about the plug in unitacl xxx *check what action you can perform on the proxy numberacc xxx restartAuxUnit *try restart the plug in unit

    If the alarm does not clear an RE will be required to visit the site.TpaDevice_AmplificationErrorRBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->AmplificationError

    This alarm is issued by the TpaDevice Managed Object (MO) when there is a faultaffecting the Transmit Power Amplifier

    (TPA) in a Multicarrier Power Amplifier (MCPA) or a Radio Unit (RU).RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms and confirm what sector is affectedcabx *will show you what MCPA is faulty if you check the LED statusget cell maxDlPowerCapability *the sector with the faulty MCPA will have a lowervaluest plug *get the proxy number of the MCPA to be restartedlpr McpaSubrack=x,RbsSlot=x,AuxPlugInUnit=1 *also used to get the proxy number o

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    14/36

    r the MCPAacl xxx *check what action you can perform on the proxy numberacc xxx restartAuxUnit *try restart the MCPAget cell maxDlPowerCapability *confirm the value has changed this value is calculated by the RBS

    RNC:moshell XXRNCX *log onto the RNClt all *load all Managed Objectsalt *show current alarmslst .xxxx *show status of channelsget cell=xxxx maximumTransmissionPower *this is a set value on the RNCThis alarm is also associated with the following alarm on the RNC:UtranCell_NbapReconfigurationFailure

    If the alarm does not clear the RE will need to go to site and change the faultyMCPA.RuDeviceGroup_GammaUplinkFailure:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->GammaUplinkFailure

    This alarm is issued by the Managed Object RuDeviceGroup. The alarm indicates afailure in one or more of the units in thegamma uplink path. Cables carry the gamma link between the following: the Baseba

    nd Interface (BBIF) and RadioFrequency Interface (RFIF) boards; the Optical Baseband Interface (OBIF) board and the RRU; the Radio Unit Interface(RUIF) and the Radio Unit (RU). Between all other boards, the physical connections are made through the backplane of theboards.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmslga | grep RbsSubrack=RU1,RbsSlot=x *see if the RU has been inter-failing

    cabx *LED status will indicate what board is faultymom AuxPlugInUnit led *description of LED statusst plug *get the proxy number of the faulty unitacl xxx *check what action you can perform on the proxy numberacc xxx restartAuxUnit *try restart the RU

    If the alarm is still present after restarting the unit lock the sector on the RNC until the RE can attend and replace the RU.

    NOTE: Identifying the affected sector:RbsSubrack=RU1/FU1,RbsSlot=2 A sectorRbsSubrack=RU1/FU1,RbsSlot=4 B sectorRbsSubrack=RU1/FU1,RbsSlot=6 C sector

    If the Radio Unit is faulty the following alarm will be present on the RNC for the disabled sectorUtranCell_NbapMessageFailure call_establishment_error UtranCell=xxxx

    RNC:moshell XXRNCX *log onto the RNClt all *load all Managed Objectsalt *show current alarmslst .xxxx *show status of channels

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    15/36

    lbl cell=xxxxA1 *lock the sector affected by the faulty RUldeb cell=xxxxA1 *once the RU has been replaced unlock the sectorPlug-In Unit General ProblemRBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->Plug-In Unit General Problem

    The alarm is issued when all defined recovery attempts are performed for the PIUor contact with the PIU is lost for at leastfive minutes.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmslga | grep Subrack=1,Slot=8,PlugInUnit=1 *check the history of the alarmcab *confirm if there is contact or not with the PIUst plug *check the state of PIUacl xxx *check what action you can perform on the PIU using the proxy numberacc xxx manualRestart *try restart the PIU

    If there's no contact with the board and the alarm does not clear an RE will be required to go to site and do a hard reset orreplace the board.RaxDeviceGroup_GeneralSwError:

    RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->GeneralSwErrorThis alarm can be sent from all Device Groups, all Device Sets, and all Devices.The RBS EM identifies which ManagedObject (MO) is issuing the alarm. The likely causes of this alarm are the following:A software faultAn incorrect version of the softwareA faulty configuration, depending on a software error (only when RruDeviceGrou

    p issues the alarm)In this case it is the RAX board that has the problem.RBS:moshell Uxxxx *log onto the node

    lt all *load all Managed Objectsalt *show current alarmscab *confirm the RAX boards on the sitest plug *check the state of the RAX boardsacl xxx *check what action you can perform on the board using the proxy numberacc xxx manualRestart *try restart the board

    Check that the alarm has cleared. If the alarm is still present an RE will needto go to site and do a hardreset or change the RAX board. Confirm the site is carrying traffic.TxDeviceGroup_GeneralSwError:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->GeneralSwError

    This alarm can be sent from all Device Groups, all Device Sets, and all Devices.The RBS EM identifies which ManagedObject (MO) is issuing the alarm. The likely causes of this alarm are the following:A software faultAn incorrect version of the softwareA faulty configuration, depending on a software error (only when RruDeviceGrou

    p issues the alarm)In this case it is the TX board that has the problem. As a consequence the capacity of the site is decreased.

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    16/36

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmscab *confirm the TX boards on the sitest plug *check the state of the TX boardsacl xxx *check what action you can perform on the board using the proxy numberacc xxx manualRestart *try restart the board

    Check that the alarm has cleared. If the alarm is still present an RE will needto go to site and do a hard reset or change theTX board. Confirm the site is carrying traffic.RaxDeviceGroup_GeneralHwError:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->GeneralHwErrorThis alarm can be sent from all Device Groups, all Device Sets, and all Devices.The RBS EM identifies which ManagedObject (MO) is issuing the alarm. This alarm indicates that the component is faulty and my need to be replaced. Thefollowing alarm `UplinkBaseBandPool_UlHwLessThanUlCapacity' will also be present onthe RBS. This indicates that thereis less hardware on the site than is licensed for as a result of the faulty RAXboard.In this case it is the RAX board that has the problem.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmscab *confirm the RAX boards on the sitest plug *check the state of the RAX boardsacl xxx *check what action you can perform on the board using the proxy numberacc xxx manualRestart *try restart the board

    Check that the alarm has cleared. If the alarm is still present an RE will needto go to site and do a hard reset or change theRAX board. Confirm the site is carrying traffic.

    LICENSE ISSUES:License Key File Fault:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->License Key file Fault

    This alarm is triggered when no valid License Key file (LKF) is found on the node. The LKF may be corrupt or have beendeleted.

    When investigating this alarm please ensure that there are no open refs (with BSS) for the site. The site could be inintegration and the license may not be loaded yet.

    CASE 1:BSS are working on the site and license has not been loaded yet.

    CASE 2:No contact with the Node. Check for alarms on transmission. If alarms are present escalate to either Transmissiondepartment or Telkom as necessary.CASE 3:Escalate to BSS to install License Key File.NOTE: For extra notes on installing a LKF see document License Issues on Node B

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    17/36

    .NodeBFunction_16QamLicenseNotValid:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->16QamLicenseNotValidThis alarm is triggered either when the 16QAM modulation license has expired orthe 16QAM modulation license has beenremoved.RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmsget . license *confirm the license installed on the nodeget . 16qam *shows the feature and license state on the nodemom . featureState16Qam *gives an explanation of the featurest pp *checks the number of E1s on the site

    NOTE: Check the MTN Configuration document to confirm what license should be installed on the site based on thenumber of E1s/Hardware. Also confirm with Optimisation what license should be installed on the Node.

    If the featurestate16Qam is ACTIVATED and the license state is DISABLED it willresult in the alarm. To clear the alarm setthe featurestate16Qam to DEACTIVATED.

    set NodeBFunction featureState16Qam 0 *Sets the feature to DISABLED since no license is installed on the sitePassword File Fault:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->Password File Fault

    The alarm indicates that the password required at Security Level 1 and 2, for user access via Telnet, SSH, FTP, SFTP or aserial port, was never set or that the locally stored passwd file has been foundto be corrupt.

    RBS:

    moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmspasswd; rbs ; rbs *resets the password on the Node Balt *confirm the alarm has clearedUpLinkBaseBandPool_ULHWLessThanULCapacity:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->ULHWLessThanULCapacityThis alarm is triggered when the installed license key file defines a capacity that is greater than the available capacity forDCH given by the installed Random Access and Receiver (RAX) boards. It can alsobe triggered due to a HW failure on oneof the RAX boards which decreases the available capacity below the capacity defi

    ned by the license key.A faulty RAX board (see alarm: RaxDeviceGroup_GeneralSwError/ RaxDeviceGroup_GeneralHwError) is the general causeof this alarm however if all RAX boards are operational and showing no errors this alarm will need to be escalated toPlanning/Optimisation to consider increasing the UL capacity on the site.RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    18/36

    get . license *shows the licensed capacity for Channel Elements in the Uplinkget nodebfunction ava *shows the available Channel Elements in the Uplink basedon the available RAX boardscab *confirm the RAX boards on the sitest plug *check the state of the RAX boards

    NOTE:Use the Product Number (from the `cab' printout) to search the ALEX document (Product Overview -> Compatibilities forHardware and Software) to confirm the number of Channel Elements supported by the RAX board.

    acl xxx *check what action you can perform on the board using the proxy numberacc xxx manualRestart *try restart the board

    If the RAX board restarts without any more alarms confirm that the ULHWLessThanULCapacity alarm has also cleared.

    alt *confirm alarm has clearedget nodebfunction ava *the available Channel Elements should now match the licensed capacity

    If the fault on the RAX board does not clear after a restart an RE will need togo to site and do a hard reset or replace the

    RAX board.DownLinkBaseBandPool_DLHWLessThanDLCapacity:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->DLHWLessThanDLCapacityThis alarm is triggered when the installed license key file defines a capacity that is greater than the available capacity forDCH given by the installed Transmitter (TX) boards. It can also be triggered dueto a HW failure on one of the TX boardswhich decreases the available capacity below the capacity defined by the licensekey.If all TX boards are operational and showing no errors this will need to be escalated to Planning/Optimisation to considerincreasing the DL capacity on the site.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmsget . license *shows the licensed capacity for Channel Elements in the Downlinkget nodebfunction ava *shows the available Channel Elements in the downlink based on the available TX boardscab *confirm the TX boards on the sitest plug *check the state of the TX boards

    NOTE:Use the Product Number (from the `cab' printout) to search the ALEX document (Product Overview -> Compatibilities for

    Hardware and Software) to confirm the number of Channel Elements supported by the TX board.NodeBFunction_DlHwUsageExceedsDlLicenseLevel:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->DlHwUsageExceedsDlLicenseLevelThis alarm is issued by the NodeBFunction Managed Object (MO) when the licensedlimit has been reached in the RBS.The cause of the alarm is that the licensed Channel Element (CE) level is reached in the RBS.

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    19/36

    NOTE:When a site uses more Channel Element capacity than is licensed a grace period will be triggered along with this alarm.Once this grace period expires the site will be limited to the licensed capacityand the alarm will be cleared

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmsget . license *shows the licensed capacity for Channel Elementsget nodeb ava *shows the available Channel Elements in the uplink/downlink basedon the installed HWget . grace *shows the grace period left for UL and DLget . limited *shows if the site is limited to the licensed capacity

    Example 1:In the example below there are 4 days grace period left. Once dlGraceTimeLeft reaches 0 the parameterdlLimitedByLicenseLevel will be set to True. A value of -1 for ulGraceTimeLeftindicates that the grace period has notyet been triggered for the UL.

    U2575-Ooseinde_VC> get . grace

    100723-12:37:46 10.205.75.161 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/10008==========================================================================================MO Attribute Value==========================================================================================NodeBFunction=1 dlGraceTimeLeft 4NodeBFunction=1 ulGraceTimeLeft -1==========================================================================================

    U2575-Ooseinde_VC> get . limited

    100723-12:37:55 10.205.75.161 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/10008======================================================================================MO Attribute Value======================================================================================NodeBFunction=1 dlLimitedByLicenseLevelfalseNodeBFunction=1 ulLimitedByLicenseLevelfalse================================================================================

    ======

    Example 2:In this example the UL and DL grace time has expired (showing a value of 0) andthe parameter ulLimitedByLicenseLeveland dlLimitedByLicenseLevel are set to True.

    U0595-Umgeni_Heights> get . grace100723-10:50:26 10.209.84.1 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/25336================================================================================

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    20/36

    =======MO Attribute Value=======================================================================================NodeBFunction=1 dlGraceTimeLeft 0NodeBFunction=1 ulGraceTimeLeft 0=======================================================================================

    U0595-Umgeni_Heights> get . limited

    100723-10:50:34 10.209.84.1 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/25336========================================================================================MO Attribute Value========================================================================================NodeBFunction=1 dlLimitedByLicenseLeveltrueNodeBFunction=1 ulLimitedByLicenseLeveltrue========================================================================================

    In order for this alarm to clear you must wait for the grace period to expire. One other way of clearing the alarm is toupgrade the license file to match the available Channel Elements. However this will be up to the planner/optimisationengineer to decide.

    In most cases this alarm can be as a result of a spike in CE usage after a siteis brought on air. All users will attempt to do alocation update and use up all resources causing this spike.

    NodeBFunction_UlHwUsageExceedsUlLicenseLevel:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->UlHwUsageExceedsUlLicenseLevel

    This alarm is issued by the NodeBFunction Managed Object (MO) when the licensedlimit has been reached in the RBS.The cause of the alarm is that the licensed Channel Element (CE) level is reached in the RBS.

    NOTE:When a site uses more Channel Element capacity than is licensed a grace period will be triggered along with this alarm.Once this grace period expires the site will be limited to the licensed capacityand the alarm will be cleared

    RBS:moshell Uxxxx *log onto the node

    lt all *load all Managed Objectsalt *show current alarmsget . license *shows the licensed capacity for Channel Elementsget nodeb ava *shows the available Channel Elements in the uplink/downlink basedon the installed HWget . grace *shows the grace period left for UL and DLget . limited *shows if the site is limited to the licensed capacity

    Example 1:In the example below there are 2 days grace period left. Once ulGraceTimeLeft r

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    21/36

    eaches 0 the parameterulLimitedByLicenseLevel will be set to True. A value of -1 for dlGraceTimeLeftindicates that the grace period has notyet been triggered for the DL.

    U4574-Elukhanyisweni_High_School> get . grace

    100723-11:02:03 10.201.89.97 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/25511===============================================================================================MO Attribute Value===============================================================================================NodeBFunction=1 dlGraceTimeLeft -1NodeBFunction=1 ulGraceTimeLeft 2===========================================================================================

    U4574-Elukhanyisweni_High_School> get . limited

    100723-11:02:42 10.201.89.97 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/25511============================================================================================

    MO Attribute Value============================================================================================NodeBFunction=1 dlLimitedByLicenseLevelfalseNodeBFunction=1 ulLimitedByLicenseLevelfalse============================================================================================

    Example 2:In this example the UL and DL grace time has expired (showing a value of 0) andthe parameter ulLimitedByLicenseLevel

    and dlLimitedByLicenseLevel are set to True.

    U0595-Umgeni_Heights> get . grace100723-10:50:26 10.209.84.1 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/25336=======================================================================================MO Attribute Value=======================================================================================NodeBFunction=1 dlGraceTimeLeft 0NodeBFunction=1 ulGraceTimeLeft 0=======================================================================================

    U0595-Umgeni_Heights> get . limited

    100723-10:50:34 10.209.84.1 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/25336========================================================================================MO Attribute Value========================================================================================NodeBFunction=1 dlLimitedByLicenseLevel

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    22/36

    trueNodeBFunction=1 ulLimitedByLicenseLeveltrue========================================================================================

    In order for this alarm to clear you must wait for the grace period to expire. One other way of clearing the alarm is toupgrade the license file to match the available Channel Elements. However this will be up to the planner/optimisationengineer to decide.In most cases this alarm can be as a result of a spike in CE usage after a siteis brought on air. All users will attempt to do alocation update and use up all resources causing this spike.

    TRANSMISSION:Loss of Tracking:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->Loss of Tracking

    The alarm is issued when the system clock enters "loss of tracking" mode. The value of the attribute, syncRefStatus is

    changed to LOSS_OF_TRACKING.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmsget 10 *prints the synchronization Managed Objectacl 10 *shows what action you can perform on the MOacc 10 resetLossOfTracking *resets loss of tracking

    When prompted to Enter mo LDN:Equipment=1,Subrack=1,Slot=2,PlugInUnit=1,ExchangeTerminal=1,E1PhysPathTerm=pp1

    NOTE: To see the values for syncRefStatus and syncRefActivity use the below commands:mom refstatemom refactivityLoss of Synch Reference Redundancy:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->Loss of Synch Reference Redundancy

    This alarm can be triggered as a consequence of the primary alarm Loss of Tracking. As a consequence of the fault, thenumber of available synchronization references is reduced and there is only oneleft. Clearing the Loss of Tracking alarmshould clear this alarm.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarmsget 10 *prints the synchronization Managed Objectacl 10 *shows what action you can perform on the MOacc 10 resetLossOfTracking *resets loss of trackingWhen prompted to Enter mo LDN:Equipment=1,Subrack=1,Slot=2,PlugInUnit=1,ExchangeTerminal=1,E1PhysPathTerm=pp1

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    23/36

    NOTE: To see the values for syncRefStatus and syncRefActivity use the below commands:mom refstatemom refactivity

    PDH Loss of Signal:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->PDH Loss of SignalThis alarm is issued by an E1 on the site when the Exchange Terminal (ET) boardcannot detect any signal at the inputport.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms this will indicate what E1/IMA Link the alarm has beentriggered forst pp *shows the status of the E1s on the sitest ima *shows the status of the IMA linksget ima *shows what IMA Link is associated with a particular E1

    E1s that are LOCKED and DISABLED they will most likely not be defined in the IMAGroup and are waiting to be integrated.

    Check on the HS 3G Site planning page to confirm number of links that are actually completed on site.http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning

    If any E1/IMA Links are UNLOCKED and DISABLED use the DXX Web Reporter to checkfor any active alarms.http://10.200.31.30/dll/w3rt.dllLogin: ESAPassword: ESA

    NOTE:To check for any errors on the E1 links use the following command:pmx e1 pm m 1

    Consult with Transmission department as for the next steps to take.

    PDH Loss of Frame:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->PDH Loss of FrameThis alarm is issued by an E1 on the site when the Exchange Terminal (ET) boardcannot detect any signal at the inputport.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objects

    alt *show current alarms this will indicate what E1/IMA Link the alarm has beentriggered forst pp *shows the status of the E1s on the sitest ima *shows the status of the IMA linksget ima *shows what IMA Link is associated with a particular E1

    E1s that are LOCKED and DISABLED they will most likely not be defined in the IMAGroup and are waiting to be integrated.Check on the HS 3G Site planning page to confirm number of links that are actually completed on site.

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    24/36

    http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning

    If any E1/IMA Links are UNLOCKED and DISABLED use the DXX Web Reporter to checkfor any active alarms.http://10.200.31.30/dll/w3rt.dllLogin: ESAPassword: ESA

    NOTE:To check for any errors on the E1 links use the following command:pmx e1 pm m 1

    Consult with Transmission department as for the next steps to take.

    Loss of Cell Delineation on IMA Link:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->Loss of Cell Delineation on IMA LinkThis alarm is triggered when the node cannot extract the ATM cells from the PDHframe. If there are many similar alarms itis likely that common hardware is at fault. However if there is just one alarm,the fault is probably with one IMA link.

    RBS:moshell Uxxxx *log onto the node

    lt all *load all Managed Objectsalt *show current alarms this will indicate what E1/IMA Link the alarm has beentriggered forst pp *shows the status of the E1s on the sitest ima *shows the status of the IMA linksget ima *shows what IMA Link is associated with a particular E1

    E1s that are LOCKED and DISABLED they will most likely not be defined in the IMAGroup and are waiting to be integrated.Check on the HS 3G Site planning page to confirm number of links that are actually completed on site.http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning

    If any E1/IMA Links are UNLOCKED and DISABLED use the DXX Web Reporter to checkfor any active alarms.http://10.200.31.30/dll/w3rt.dllLogin: ESAPassword: ESA

    NOTE:To check for any errors on the E1 links use the following command:pmx e1 pm m 1Consult with Transmission department as for the next steps to take.Remote Defect Indication on IMA Link:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->Remote Defect Indication on IMA Link

    This alarm is triggered when the remote (far end) node has detected a transmission fault on the IMA link. This will alsotrigger the alarm `IMA Link Reception Unusable at Far End' indicating that the linkat the far end has become unusable.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms this will indicate what E1/IMA Link the alarm has been

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    25/36

    triggered forst pp *shows the status of the E1s on the sitest ima *shows the status of the IMA linksget ima *shows what IMA Link is associated with a particular E1

    E1s that are LOCKED and DISABLED they will most likely not be defined in the IMAGroup and are waiting to be integrated.Check on the HS 3G Site planning page to confirm number of links that are actually completed on site.http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning

    If any E1/IMA Links are UNLOCKED and DISABLED use the DXX Web Reporter to checkfor any active alarms.http://10.200.31.30/dll/w3rt.dllLogin: ESAPassword: ESA

    NOTE:To check for any errors on the E1 links use the following command:pmx e1 pm m 1

    Consult with Transmission department as for the next steps to take. However in most cases this will need to be escalatedto Telkom.

    IMA Link Reception Unusable at Far End:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->IMA Link Reception Unusable at FarEnd

    This alarm is triggered when the IMA link at the far end becomes unusable. It islikely that you will also see the alarm`Remote Defect Indication on IMA Link' for the same link indicating that the IMA link is faulty.

    RBS:moshell Uxxxx *log onto the node

    lt all *load all Managed Objectsalt *show current alarms this will indicate what E1/IMA Link the alarm has beentriggered forst pp *shows the status of the E1s on the sitest ima *shows the status of the IMA linksget ima *shows what IMA Link is associated with a particular E1

    E1s that are LOCKED and DISABLED they will most likely not be defined in the IMAGroup and are waiting to be integrated.Check on the HS 3G Site planning page to confirm number of links that are actually completed on site.http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning

    If any E1/IMA Links are UNLOCKED and DISABLED use the DXX Web Reporter to checkfor any active alarms.http://10.200.31.30/dll/w3rt.dllLogin: ESAPassword: ESA

    NOTE:To check for any errors on the E1 links use the following command:pmx e1 pm m 1

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    26/36

    Consult with Transmission department as for the next steps to take. However in most cases this will need to be escalatedto Telkom.IMA Link Reception Misconnected:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->IMA Link Reception Misconnected

    This alarm is triggered when there is a configuration mismatch between two nodes. The IMA link in the receive direction isnot connected to the same remote (far end) IMA unit as the other reception linksin the IMA group. It is likely that you willsee one or both of the following alarms: `Remote Defect Indication on IMA Link', `IMALink Reception Unusable at Far End'.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms this will indicate what E1/IMA Link the alarm has beentriggered forst pp *shows the status of the E1s on the sitest ima *shows the status of the IMA linksget ima *shows what IMA Link is associated with a particular E1

    E1s that are LOCKED and DISABLED they will most likely not be defined in the IMA

    Group and are waiting to be integrated.Check on the HS 3G Site planning page to confirm number of links that are actually completed on site.http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning

    If any E1/IMA Links are UNLOCKED and DISABLED use the DXX Web Reporter to checkfor any active alarms.http://10.200.31.30/dll/w3rt.dllLogin: ESAPassword: ESA

    NOTE:To check for any errors on the E1 links use the following command:

    pmx e1 pm m 1

    Consult with Transmission department as for the next steps to take. However in most cases this will need to be escalatedto Telkom.

    IMA Group Insufficient Links:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->IMA Link Insufficient LinksThis alarm is triggered when one or more of the IMA links have failed. This reduces the number of IMA Links in the IMAgroup and the required number of links is less than defined.RBS:

    moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms this will indicate what E1/IMA Link the alarm has beentriggered forst pp *shows the status of the E1s on the sitest ima *shows the status of the IMA linksget ima *shows what IMA Link is associated with a particular E1get ima required *shows the required number of links needed in the IMA group

    CASE 1:

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    27/36

    In the below example there are two UNLOCKED and ENABLED E1 links. However thereis only 1 E1 link defined in the IMAgroup.

    U4784-Vredenburg_WPK_Silo> st pp

    100730-12:08:56 10.202.83.113 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/29260===================================================================================Proxy Adm State Op. State MO===================================================================================110 1 (UNLOCKED) 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu

    =1,ExchangeTerminal=1,E1PhysPathTerm=pp1111 0 (LOCKED) 0 (DISABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu

    =1,ExchangeTerminal=1,E1PhysPathTerm=pp2114 1 (UNLOCKED) 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu

    =1,ExchangeTerminal=1,E1PhysPathTerm=pp3===================================================================================

    U4784-Vredenburg_WPK_Silo> st ima

    100730-12:09:02 10.202.83.113 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/29260

    ===================================================================================Proxy Adm State Op. State MO===================================================================================

    17 0 (DISABLED) TransportNetwork=1,AtmPort=1-1-ima149 0 (DISABLED) TransportNetwork=1,ImaGroup=1-1-ima150 1 (ENABLED) TransportNetwork=1,ImaGroup=1-1-ima1,ImaLink=

    1===================================================================================

    U4784-Vredenburg_WPK_Silo> get ima required

    100730-12:22:21 10.202.83.113 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/29260===================================================================================MO Attribute Value===================================================================================ImaGroup=1-1-ima1 requiredNumberOfLinks 1===================================================================================

    Check on the HS 3G Site planning page to confirm the number of links that are actually completed on site.

    http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning

    In the above example BSS will be required to do an IMA upgrade and add the 2ndworking link to the IMA group. You mightalso need to contact Transmission and confirm what the correct configuration ison the DXX.

    IMA Group Insufficient Links at Far End:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->I

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    28/36

    MA Group Insufficient Links at FarEnd

    This alarm is triggered when one or more of the IMA links have failed. This reduces the number of IMA Links in the IMAgroup and the required number of links is less than defined.RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms this will indicate what E1/IMA Link the alarm has beentriggered forst pp *shows the status of the E1s on the sitest ima *shows the status of the IMA linksget ima *shows what IMA Link is associated with a particular E1get ima required *shows the required number of links needed in the IMA group

    CASE 1:In the below example there are two UNLOCKED and ENABLED E1 links. However thereis only 1 E1 link defined in the IMAgroup.

    U4784-Vredenburg_WPK_Silo> st pp

    100730-12:08:56 10.202.83.113 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/29260

    ===================================================================================Proxy Adm State Op. State MO===================================================================================110 1 (UNLOCKED) 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu

    =1,ExchangeTerminal=1,E1PhysPathTerm=pp1111 0 (LOCKED) 0 (DISABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu

    =1,ExchangeTerminal=1,E1PhysPathTerm=pp2114 1 (UNLOCKED) 1 (ENABLED) Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu

    =1,ExchangeTerminal=1,E1PhysPathTerm=pp3===================================================================================

    U4784-Vredenburg_WPK_Silo> st ima

    100730-12:09:02 10.202.83.113 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/29260===================================================================================Proxy Adm State Op. State MO===================================================================================

    17 0 (DISABLED) TransportNetwork=1,AtmPort=1-1-ima149 0 (DISABLED) TransportNetwork=1,ImaGroup=1-1-ima150 1 (ENABLED) TransportNetwork=1,ImaGroup=1-1-ima1,ImaLink=

    1

    ===================================================================================

    U4784-Vredenburg_WPK_Silo> get ima required

    100730-12:22:21 10.202.83.113 8.0c RBS_NODE_MODEL_M_1_8 stopfile=/tmp/29260===================================================================================MO Attribute Value================================================================================

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    29/36

    ===ImaGroup=1-1-ima1 requiredNumberOfLinks 1===================================================================================

    Check on the HS 3G Site planning page to confirm the number of links that are actually completed on site.http://10.217.201.232/facts/report/Tx/DXX/8600/Planning/3G+HS+Site+Planning

    In the above example BSS will be required to do an IMA upgrade and add the 2ndworking link to the IMA group. You mightalso need to contact Transmission and confirm what the correct configuration ison the DXX.Heartbeat Failure:OSS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarm Handling Operational Instruction ->Heartbeat Failure

    This alarm can be triggered when connectivity to the OSS is lost or the site hasgone down due to transmission.

    RBS:moshell Uxxxx *log onto the node

    If you cannot MOSHELL to the node check for alarms on the RNC

    riorda_m@uas3g3> moshell u2652

    __ __ ____ _____/\ | \/ |/ __ \ / ____|

    / \ | \ / | | | | (___/ /\ \ | |\/| | | | |\___ \

    / ____ \| | | | |__| |____) |/_/ \_\_| |_|\____/|_____/OSS Framework for MoShell-8.0c

    Checking ip contact...Not OK

    Unable to connect to 10.209.89.241:23Cannot connect to MO service, exiting...

    RNC:moshell XXRNCX *log onto the RNClt all *load all Managed Objectsalt *show current alarmslst .xxxx *show status of channelspmx cell=xxxx pmTotNoRrcC|pmNoSystemRabRe|pmNoRabEstablish|pmNoNormalRabRel|pmNoFailedAfterAdm -m 1 *confirmif the site is carrying traffic

    CASE 1 Site is operational and carrying traffic but no connection to the node:

    If all channels are unlocked and enabled, the site is carrying traffic and no alarms are present on the RNC escalate this faultto Transmission/IP Routing. In this case VC32 and VC33 (used for O&M connectivity) will need to be checked byTransmission. Transmission will possibly need to recreate these VCs as they arehanging.

    Use the command `traceroute ' to confirm where the problem is beforeescalating to Transmission. Thetraceroute command shows where the IP packet stops in the network, either at the

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    30/36

    DXX or IP router.

    riorda_m@uas3g3> traceroute 10.204.78.145traceroute: Warning: Multiple interfaces found; using 10.217.12.16 @ ce1traceroute to 10.204.78.145 (10.204.78.145), 30 hops max, 40 byte packets1 10.217.12.252 (10.217.12.252) 0.614 ms 0.349 ms 0.279 ms2 10.195.17.165 (10.195.17.165) 1.043 ms 0.878 ms 0.901 ms3 10.195.17.13 (10.195.17.13) 0.952 ms 0.816 ms 0.844 ms4 10.90.217.5 (10.90.217.5) 1.418 ms 0.991 ms 90.119 ms5 10.90.250.14 (10.90.250.14) 1.840 ms 6.803 ms 1.097 ms6 10.90.204.6 (10.90.204.6) 1.317 ms 1.131 ms 0.938 ms7 10.204.47.252 (10.204.47.252) 0.855 ms 0.859 ms 0.729 ms8 10.204.47.230 (10.204.47.230) 1.505 ms 1.504 ms 1.940 ms9 10.204.78.145 (10.204.78.145) 7.887 ms 7.250 ms 8.814 msriorda_m@uas3g3>

    CASE 2 Site is DISABLED and there are alarms present on the RNC:If the channels on the RNC are UNLOCKED and DISABLED and there are alarms present on the RNC it is more than likely aproblem on the Transmission side and will need to be escalated to TX or Telkom based on the alarms present on the DXX.

    Possible RNC Alarms:NbapDedicated_RncRbsControlLinkDown transmission_error IubLink=Iub_U2652-Bay

    _View_Estates,NbapDedicated=1UtranCell_ServiceUnavailable unavailable UtranCell=2652A1

    UtranCell_ServiceUnavailable unavailable UtranCell=2652B1

    UtranCell_ServiceUnavailable unavailable UtranCell=2652C1

    CASE 3 New SiteCheck in REMEDY if this is a new site. Generally a new site that is not yet fully integrated will display the Heartbeat Failurealarm as it is not yet connected on the OSS.

    MISCELLANEOUS:

    Carrier_RejectSignalFromHardwareRBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->RejectSignalFromHardware

    This alarm is triggered by the Carrier Managed Object. This alarm can be issuedfor the AIU/sAIU, FU, MCPA, RFIF board,RRU, RU, TRX board or the TX board. If none of the boards are faulty it could berelated to a frequency configuration issue.

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms

    cabx *check the equipment on the site (particularly the RU and FU)get . fqband *check the highedge and lowedge of the Antenna Branch

    Contact optimisation/planning to confirm that the UARFCNs and high and low edgesare set correctly. If they are setcorrectly restart the RU relevant to the affected sector.

    st plug *shows the plug in units.acl xxx *check what action you can perform on the PIU using the proxy numberacc xxx manualRestart *try restart the PIU

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    31/36

    NOTE: Identifying the affected sector:RbsSubrack=RU/FU, RbsSlot=2 A sectorRbsSubrack=RU/FU, RbsSlot=4 B sectorRbsSubrack=RU/FU, RbsSlot=6 C sector

    RNC:moshell XXRNCX *log onto the RNClt all *load all Managed Objectsalt *show current alarmslst .xxxx *show status of channels some carriers may be disabledget cell=xxxx uarfcn *displays the DL and UL frequencies set for each carrier

    The following alarm may be present on the RNC:UtranCell_NbapMessageFailureNbapCommon_Layer3SetupFailure:RBS Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->Layer3SetupFailureThis alarm is issued by the NbapCommon Managed Object. It is issued for the NodeB Application Protocol (NBAP)Common. The likely cause is a communication failure between the RBS and RNC. Thefollowing alarm,`UtranCell_ExternalResourceUnavailable' could also be present on the RNC for the aff

    ected cells.RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms

    RNC:moshell XXRNCX *log onto the RNClt all *load all Managed Objectsalt *show current alarmslst .xxxx *show status of channels all cells will be DISABLED and also NbapCommom on the IubLink================================================================================

    ========14622 1 (UNLOCKED) 1 (ENABLED) RncFunction=1,IubLink=Iub_U2141-Adgam_Place14624 0 (DISABLED) RncFunction=1,IubLink=Iub_U2141-Adgam_Place,NodeSynch=114625 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,IubLink=Iub_U2141-Adgam_Place,NbapCommon=114626 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,IubLink=Iub_U2141-Adgam_Place,NbapDedicated=122656 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,UtranCell=2141A122669 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,UtranCell=2141A1,Hsdsch=122670 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,UtranCell=2141A1,Hsdsch=1,Eul=122684 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,UtranCell=2141A1,Rach=RACH

    22685 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,UtranCell=2141A1,Pch=PCH22695 1 (UNLOCKED) 0 (DISABLED) RncFunction=1,UtranCell=2141A1,Fach=1========================================================================================

    lbl Iublink_Iub_Uxxxx *block the IubLink

    GERNC1> lbl Iublink=Iub_U2141===================================================================================

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    32/36

    14622 RncFunction=1,IubLink=Iub_U2141-Adgam_Place14625 RncFunction=1,IubLink=Iub_U2141-Adgam_Place,NbapCommon=114626 RncFunction=1,IubLink=Iub_U2141-Adgam_Place,NbapDedicated=1===================================================================================

    ldeb Iublink_Iub_Uxxxx *deblock the IubLinklst .xxxx confirm the channels are UNLOCKED and ENABLED

    Confirm the alarm has cleared on the RBS. If the alarm is still present escalateto Transmission.

    RNC:UtranCell_NbapReconfigurationFailure:RNC Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->UtranCell_NbapReconfigurationFailure

    RBS does not provide the configured output power due to some internal hardware problems. Check the RBS for any HWfaults, generally with the MCPA units.

    RNC:moshell XXRNCX *log onto the RNC

    lt all *load all Managed Objectsalt *show current alarmslst .xxxx *show status of channelsget cell=xxxx maximumTransmissionPower *this is a set value on the RNCRNC will internally set a reference value representing the previously configuredmaximumTransmissionPower in the cell.An alarm will be issued if the RBS reports a degradation of its maxPowerCapDl below 2dB.

    This alarm can be associated with the following alarm on the RBS:TpaDevice_AmplificationError

    RBS:

    moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms and confirm what sector is affectedcabx *will show you what MCPA is faulty if you check the LED statusget cell maxDlPowerCapability *the sector with the faulty MCPA will have a lowervaluest plug *get the proxy number of the MCPA to be restartedlpr McpaSubrack=x,RbsSlot=x,AuxPlugInUnit=1 *also used to get the proxy number or the MCPAacl xxx *check what action you can perform on the proxy numberacc xxx restartAuxUnit *try restart the MCPAget cell maxDlPowerCapability *confirm the value has changed this value is calculated by the RBS

    If the alarm does not clear the RE will need to go to site and change the faultyMCPA.

    NbapDedicated_RncRbsControlLinkDown:RNC Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->NbapDedicated_RncRbsControlLinkDown

    This alarm is triggered when there is a temporary disturbance or interruption inthe Iub link . It is also generally

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    33/36

    associated with the alarm UtranCell_ServiceUnavailable as all Utrancells will beDISABLED.

    RNC:moshell XXRNCX *log onto the RNClt all *load all Managed Objectsalt *show current alarmslst .xxxx *show status of channels cells will be UNLOCKED and DISABLED

    This alarms indicates a problem with Transmission. It will need to be either escalated to the Transmission department orTelkom. When this alarm is present you will be unable to Moshell onto the RBS.

    Check the DXX web reporter for any current alarms.http://10.200.31.30/dll/w3rt.dllLogin: ESAPassword: ESA

    Once the Transmission issue has been cleared, confirm that all cells and channels are UNLOCKED and ENABLED and thesite is carrying traffic.

    UtranCell_ServiceUnavailable:

    RNC Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->UtranCell_ServiceUnavailableThis is a secondary alarm and is triggered when there is a problem with the NBAPsignalling on the Transmission link. It isassociated with the alarm NbapDedicated_RncRbsControlLinkDown

    RNC:moshell XXRNCX *log onto the RNClt all *load all Managed Objectsalt *show current alarmslst .xxxx *show status of channels cells will be UNLOCKED and DISABLED

    This alarm could indicate a problem with Transmission. It will need to be either

    escalated to the Transmission departmentor Telkom.

    Check the DXX web reporter for any current alarms.http://10.200.31.30/dll/w3rt.dllLogin: ESAPassword: ESA

    UtranCell_ExternalResourceUnavailable:RNC Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->UtranCell_ExternalResourceUnavailableThis alarm is triggered by the Utrancell Managed Object. It is issued for the Node B Application Protocol (NBAP) Common.

    The likely cause is a communication failure between the RBS and RNC. The following alarm, `NbapCommon_Layer3SetupFailure' could also be present on the RBS.RNC:moshell XXRNCX *log onto the RNClt all *load all Managed Objectsalt *show current alarmslst .xxxx *show status of channels all cells will be DISABLED

    Check the RBS for any alarms.

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    34/36

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms

    This alarm could point to a problem with Transmission. It will need to be eitherescalated to the Transmission departmentor Telkom.

    Check the DXX web reporter for any current alarms.http://10.200.31.30/dll/w3rt.dllLogin: ESAPassword: ESA

    UtranCell_RBSLocalCellNotAdded:RNC Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->UtranCell_RBSLocalCellNotAdded

    This alarm is triggered when the RNC is trying to activate the UTRANCELL but isunable to as there is a mis-configurationwith the RBS Local Cell on the RBS. The alarm UtranCell_NbapMessageFailure couldalso be present for the affectedsectors.

    RNC:moshell XXRNCX *log onto the RNClt all *load all Managed Objectsalt *show current alarmslst .xxxx *show status of channels cells will be UNLOCKED and DISABLEDget cell=xxxx cid *check the Cell ID on the RNC

    RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms and confirm what sector is affectedget rbslocalcell cellid *check the Cell ID on the RBS and confirm the mismatchCheck the FACTs page to confirm the correct Cell ID to be used CI Allocation Look

    uphttp://10.217.201.232/facts/report/CI_TRANSLATION/CI_TRANSLATION_LOGIf the RBS that has the incorrect values use the following command to correct it:set rbslocalcell=SXCX localCellId=xxxxx *corrects the Cell ID on the RBSNOTE:S1C1 Sector 1,Carrier1S1C2 Sector1,Carrier2 etc.....

    If the RNC has the incorrect value use the following command to correct it:set cell=xxxxA1 cid=xxxxx *corrects the Cell ID on the RNC

    Confirm alarm has cleared and the cells are UNLOCKED and ENABLED.

    Finally be sure to save a CV see Node B Restart Procedure for help on creating aCV.cvlscvms [cvname_date_time][ursername][comment]

    UtranCell_NbapMessageFailure:RNC Library in ALEX: Operation and Maintenance -> Fault Management -> Alarms ->UtranCell_NbapMessageFailureThis alarm can be triggered when the RBS cannot fulfil the request to set up a UTRAN Cell issued by the RNC. The RBS will

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    35/36

    need to be checked for any alarms.RNC:moshell XXRNCX *log onto the RNClt all *load all Managed Objectsalt *show current alarmslst .xxxx *show status of channels all cells will be DISABLED

    Check the RBS for any alarms.RBS:moshell Uxxxx *log onto the nodelt all *load all Managed Objectsalt *show current alarms

    CASE 1 Hardware Failure on RBS:A faulty TX board on the RBS can cause the untrancells on the RNC to be DISABLED. See alarm `Plug-In Unit GeneralProblem'.

    EXTRA NOTES:MTN Configuration Types

    MTNCONFIG V1.7B.xlsRBS 3202RBS3202 -Snapshot.docx

    SMOKE Text AnalysisSMOKE TEXTInvestigation.docx

    Node B Restart Procedure

    Node B RestartProcedure.pptLicense Issues on Node BLicense Issues onNode B.ppt

    USEFUL Commands:

    Checking Performance:

    RNC:pmx cell=xxxx pmtotnoutranrejrrcconnreq|pmNoFailedAfterAdm -m 1 *shows rejections and failures for the lasthourpmx cell=xx pmTotNoRrcC|pmNoSystemRabRe|pmNoSysRelSpeech|pmNoRabEstablish|pmNoNormalRabRel|pmNoFailedAfterAdm-m 1pmx utrancell=xxxx pmCellDowntime -m 4 *shows downtime for last 4 hourspmr *displays all the predefined performance reports on the RNC

  • 7/24/2019 237310160 Alarm Handling Guide Moshell Commands

    36/36

    pmom . *gives a description of a specific counterpmom . pmCellDowntimeAutomom . *gives a description of a particular parameterpmx plug processorload -m 1 *shows processor load on individual boards

    RBS:pmx e1 pm m 1 *shows the errored seconds and severely errored seconds for the E1links over the last hourpgets e1 *shows the current errors on the E1 linkspmx aal2ap pmunsuc -m 2 *show all unsuccessful attempts across the aal2 paths for all classespmx edch pmnoallowedeulpgets *shows all active counters on the RBSpmr *displays all the predefined performance reports on the RBSget radio no *shows the current number of active radio links

    Locking and Unlocking site on RNC:

    RNC:moshell XXRNCX *log onto the RNClt all *load all Managed Objectsalt *show current alarmslst .xxxx *show status of channels confirm if site has one or two carriers

    bls cell=xxxx *soft blocks the cells takes 5 minuteslbl cell=xxxx *blocks all the channelslst .xxxx *confirm the channels are LOCKED and DISABLEDldeb cell=xxxx *unlock cells and channels one sector at a timelst .xxxx *confirm the channels are UNLOCKED and ENABLED

    Miscellaneous:ala *shows current alarms WITH detailsaltk *shows current alarms UNACKNOWLEDGED and ACKNOWLEDGEDget 0 *shows equipment typelicense key *shows licenses installed on the nodecvls *prints configuration version on the node