2120xl - teledyne analytical instruments and humidity control module plasma emission detector module...

4
2120XL Trace Nitrogen Analyzer Plasma Ionization Technology Model FEATURES: • For use in Argon or Helium background • 5 ppb detectable limit • Maintenance-free • No switching valves, column or carrier gas required • Integral digital sample flow control • Microprocessor-based electronics with menu-driven functionality and diagnostics • Large, luminescent LCD display and 2x20 vacuum fluorescent display to show menu functions and parameters • Profibus DP ready with Teledyne Valve Box

Upload: vuonglien

Post on 14-May-2018

236 views

Category:

Documents


1 download

TRANSCRIPT

2120XLTrace Nitrogen AnalyzerPlasma Ionization Technology

Model

FEATURES:

• ForuseinArgonorHeliumbackground

• 5ppbdetectablelimit

• Maintenance-free

• Noswitchingvalves,columnorcarriergasrequired

• Integraldigitalsampleflowcontrol

• Microprocessor-basedelectronicswith menu-drivenfunctionalityanddiagnostics

• Large,luminescentLCDdisplayand2x20 vacuumfluorescentdisplaytoshowmenufunctions

andparameters

• ProfibusDPreadywithTeledyneValveBox

FlowandHumidityControlModule

PlasmaEmissionDetectorModule

MicroprocessorPCB

PowerSupplyPCB

PreamplifierPCB

MODEL 2120XL - Trace Nitrogen Analyzer

Inmanyargonorheliumgassupplysystems,thedetectionof trace nitrogen (N2) is essential in determining systemintegrity.TeledyneAnalyticalInstrumentsModel2120XListhenewstandardinthiscriticalmeasurement. Itprovidescontinuous and accurate nitrogen analysis using field-provenemissionspectroscopictechnologyinaspace-saving19”rack-mount3Upackage.

The 2120XL’s unique design raises the bar for reliabilityavailableonthemarket.The2120XLusesamenu-adjustable,digitallycontrolledsampleflowforallapplications.Duringoperations,the2120XLallowsforawiderangeofpressureswithout affecting readings with a low overall sample flowrequirement.ItsplasmaemissiondetectordesignisbasedonauniqueDutyCycleControlledSystemwhichdramaticallyreducescontaminationandcoatinginsidetheplasmacell,offering a more efficient, reliable, and accurate analyzerthananyothersystemavailable.

Its non-consuming sensing technology requires no regularmaintenance or replacement intervals, providing ultra-lowdetectability without themaintenance overhead of similarhigh-performance systems. Even when maintenance isrequired, the 2120XL offers ease of access to all internalcomponentswhichminimizesdowntime.Anewdesignandspecialized components alsominimizes necessary volumeforpurge-downtime.

The2120XLoperateswithmicroprocessor-basedelectronicsutilizing menu-driven functionality. Users are provided alarge,luminescentLCDdisplayand2x20vacuumfluorescentdisplays to show all menu functions and parameters. Apreamplifier with multiple stage gains supports a widedynamic operating range. The 2120XL also offers a fulldiagnosticssuite includingadisplayof rawmillivoltsignalfortroubleshooting.

2

• Airseparationunit • Cryogenictruckloadingstation • Specialtygaslaboratories • Processcontrol • Argonpurificationplant • SteelIndustries

• Chemicalplants • Weldinggascontrol • Heliumliquefactionplants • Gasmanagementsystem • Semiconductormanufacturing • Qualitycontrolfortruckfillsandgascylinders

APPLICATIONS:

MODEL 2120XL - Trace Nitrogen Analyzer

3

Range 0-1,0-10,0-100ppm,user-settable,fixedorauto-ranging.Higherrangesoptional

Resolution PPMReadout:0.01ppmbelow10.0ppm,0.1ppmatorabove10.0ppmPPBReadout:0.1ppb

Accuracy 1%offullscale

Drift 1%offullscale

GasConnections 1/8inchtubefitting

CalibrationGas Zero:purifiedargon/helium”and“Span:PPMnitrogeninargon/helium

SampleFlow 20-200sccm,programmable

OperatingPressure 4-30psig

OperatingTemperature 10-35°C(50-95°F)

Power 110-240VAC50/60Hz,60wattsmax

Dimensions(HxWxD) 5.22x19.00x18.40in(132.6x482.6x467.4mm)(3Uformfactor)

Weight Approximately35pounds

SPECIFICATIONS:

• Moisturetrap(TAIpartnumberS1766)

• Scrubberforpurificationofzerogas(TAIpartnumberS1748)

OPTIONAL EQUIPMENT:

• Microprocessorbasedelectronics

• User-settableranges

• 4-20mAisolatedanalogoutput

• Self-diagnosticswithForm-Csystemalarmcontact

• Two(2)fully-programmableconcentrationalarmswithForm-Ccontact

• RangeIdentification:Form-Acontactsand0-1VDC

• RS-232bi-directionalserialoutput

• Digitally-settableflowrate

• Optionalintegralauto-calibrationvalvemanifold

• ProfibusDPcommunicationsoptionwhenusedinconjunctionwithTAIValveBox

ELECTRONICS/INTERFACE:

4

Teledyne Analytical Instruments (TAI) - Factory16830 Chestnut StreetCity of Industry, CA 91748, USATOLL FREE (888) 789-8168TEL: 626.934.1500FAX: 626.934.1651www.teledyne-ai.com

TAI - Houston & Gulf Coast Region USAShana KiserSales EngineerTEL: 281.557.8740MOB: 281.685.3758FAX: 281.557.8741E-mail: [email protected]

TAI - Southeast USADave SolomonSales ManagerTEL: 281.471.2935MOB: 281.414.8236FAX: 281.471.3091E-mail: [email protected]

TAI - Middle East and IndiaManoj KumarPO Box 8976Y2-113 SAIF ZoneSharjahUNITED ARAB EMIRATES (UAE)TEL: 971.6.5575.704MOB: 971.5.0634.5537E-mail: [email protected]

TAI - So. East AsiaSoo Keong LimNo. J-03-2, Dataran GlomacJalan SS6/18, Pusat Bandar Kelana Jaya47301 Kelana JayaSelangorMALAYSIATEL: 603.7805.7712FAX: 603.7805.7710MOB: 6012.2010.610E-mail: [email protected]

TAI - South AmericaAngel Luhia (consultant)Av. Dellepiane 4208(C1407H2W) Buenos AiresARGENTINATEL & FAX: 54.11.4601-0050MOB: 54.911.5388-3664E-mail: [email protected]: [email protected]

WarrantyInstrument is warranted for one year against defects inmaterial or workmanship

NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice.