2120xl - teledyne analytical instruments and humidity control module plasma emission detector module...
TRANSCRIPT
2120XLTrace Nitrogen AnalyzerPlasma Ionization Technology
Model
FEATURES:
• ForuseinArgonorHeliumbackground
• 5ppbdetectablelimit
• Maintenance-free
• Noswitchingvalves,columnorcarriergasrequired
• Integraldigitalsampleflowcontrol
• Microprocessor-basedelectronicswith menu-drivenfunctionalityanddiagnostics
• Large,luminescentLCDdisplayand2x20 vacuumfluorescentdisplaytoshowmenufunctions
andparameters
• ProfibusDPreadywithTeledyneValveBox
FlowandHumidityControlModule
PlasmaEmissionDetectorModule
MicroprocessorPCB
PowerSupplyPCB
PreamplifierPCB
MODEL 2120XL - Trace Nitrogen Analyzer
Inmanyargonorheliumgassupplysystems,thedetectionof trace nitrogen (N2) is essential in determining systemintegrity.TeledyneAnalyticalInstrumentsModel2120XListhenewstandardinthiscriticalmeasurement. Itprovidescontinuous and accurate nitrogen analysis using field-provenemissionspectroscopictechnologyinaspace-saving19”rack-mount3Upackage.
The 2120XL’s unique design raises the bar for reliabilityavailableonthemarket.The2120XLusesamenu-adjustable,digitallycontrolledsampleflowforallapplications.Duringoperations,the2120XLallowsforawiderangeofpressureswithout affecting readings with a low overall sample flowrequirement.ItsplasmaemissiondetectordesignisbasedonauniqueDutyCycleControlledSystemwhichdramaticallyreducescontaminationandcoatinginsidetheplasmacell,offering a more efficient, reliable, and accurate analyzerthananyothersystemavailable.
Its non-consuming sensing technology requires no regularmaintenance or replacement intervals, providing ultra-lowdetectability without themaintenance overhead of similarhigh-performance systems. Even when maintenance isrequired, the 2120XL offers ease of access to all internalcomponentswhichminimizesdowntime.Anewdesignandspecialized components alsominimizes necessary volumeforpurge-downtime.
The2120XLoperateswithmicroprocessor-basedelectronicsutilizing menu-driven functionality. Users are provided alarge,luminescentLCDdisplayand2x20vacuumfluorescentdisplays to show all menu functions and parameters. Apreamplifier with multiple stage gains supports a widedynamic operating range. The 2120XL also offers a fulldiagnosticssuite includingadisplayof rawmillivoltsignalfortroubleshooting.
2
• Airseparationunit • Cryogenictruckloadingstation • Specialtygaslaboratories • Processcontrol • Argonpurificationplant • SteelIndustries
• Chemicalplants • Weldinggascontrol • Heliumliquefactionplants • Gasmanagementsystem • Semiconductormanufacturing • Qualitycontrolfortruckfillsandgascylinders
APPLICATIONS:
MODEL 2120XL - Trace Nitrogen Analyzer
3
Range 0-1,0-10,0-100ppm,user-settable,fixedorauto-ranging.Higherrangesoptional
Resolution PPMReadout:0.01ppmbelow10.0ppm,0.1ppmatorabove10.0ppmPPBReadout:0.1ppb
Accuracy 1%offullscale
Drift 1%offullscale
GasConnections 1/8inchtubefitting
CalibrationGas Zero:purifiedargon/helium”and“Span:PPMnitrogeninargon/helium
SampleFlow 20-200sccm,programmable
OperatingPressure 4-30psig
OperatingTemperature 10-35°C(50-95°F)
Power 110-240VAC50/60Hz,60wattsmax
Dimensions(HxWxD) 5.22x19.00x18.40in(132.6x482.6x467.4mm)(3Uformfactor)
Weight Approximately35pounds
SPECIFICATIONS:
• Moisturetrap(TAIpartnumberS1766)
• Scrubberforpurificationofzerogas(TAIpartnumberS1748)
OPTIONAL EQUIPMENT:
• Microprocessorbasedelectronics
• User-settableranges
• 4-20mAisolatedanalogoutput
• Self-diagnosticswithForm-Csystemalarmcontact
• Two(2)fully-programmableconcentrationalarmswithForm-Ccontact
• RangeIdentification:Form-Acontactsand0-1VDC
• RS-232bi-directionalserialoutput
• Digitally-settableflowrate
• Optionalintegralauto-calibrationvalvemanifold
• ProfibusDPcommunicationsoptionwhenusedinconjunctionwithTAIValveBox
ELECTRONICS/INTERFACE:
4
Teledyne Analytical Instruments (TAI) - Factory16830 Chestnut StreetCity of Industry, CA 91748, USATOLL FREE (888) 789-8168TEL: 626.934.1500FAX: 626.934.1651www.teledyne-ai.com
TAI - Houston & Gulf Coast Region USAShana KiserSales EngineerTEL: 281.557.8740MOB: 281.685.3758FAX: 281.557.8741E-mail: [email protected]
TAI - Southeast USADave SolomonSales ManagerTEL: 281.471.2935MOB: 281.414.8236FAX: 281.471.3091E-mail: [email protected]
TAI - Middle East and IndiaManoj KumarPO Box 8976Y2-113 SAIF ZoneSharjahUNITED ARAB EMIRATES (UAE)TEL: 971.6.5575.704MOB: 971.5.0634.5537E-mail: [email protected]
TAI - So. East AsiaSoo Keong LimNo. J-03-2, Dataran GlomacJalan SS6/18, Pusat Bandar Kelana Jaya47301 Kelana JayaSelangorMALAYSIATEL: 603.7805.7712FAX: 603.7805.7710MOB: 6012.2010.610E-mail: [email protected]
TAI - South AmericaAngel Luhia (consultant)Av. Dellepiane 4208(C1407H2W) Buenos AiresARGENTINATEL & FAX: 54.11.4601-0050MOB: 54.911.5388-3664E-mail: [email protected]: [email protected]
WarrantyInstrument is warranted for one year against defects inmaterial or workmanship
NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice.