contentmesure.optoprim.com/.../uploads/2016/04/hyspex_brochure.pdf · 2019-10-10 · 0.05 sample...

28

Upload: others

Post on 05-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

1

Page 2: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

2

Content

4 About

5 Data Quality

6 HySpex Classic

14 HySpex Mjolnir

20 HySpex Baldur

24 Technical Specs

27 Contact

Page 3: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

3

Page 4: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

4

NEO - playing a leading role in applied researchNorsk Elektro Optikk was established in 1985 as a privately owned research company within the field of electro optics. The founders had their scientific and technical background from the Norwegian Defence Research Establishment, at that time the leading research organization in electro optics in Norway. The company’s objective is to play a leading role in applied research within its area of expertise to develop and manufacture advanced industrial products for an international market.

The company has grown to be the largest independent research and development organization in electro optics in Norway and has established itself as a reputed manufacturer of advanced electro optical products. NEO is certified to the ISO 9001:2015 International quality standards.

HySpex – the industry leading brandThe hyperspectral imaging activities at NEO started in 1995 with the HISS (Hyperspectral Imager for Small Satellites) project for ESA. The R&D activities in hyperspectral imaging have been internally funded through commercialization of the technology together with participation in several EU projects, as well asprojects funded by the Ministry of Defense, the Norwegian Research Council etc.

Today, HySpex is established as an industry leading brand for both airborne and ground based hyperspectral imaging. HySpex sensors are renowned for their stability, flexibility and superior data quality.

www.hyspex.no | Norsk Elektro Optikk AS | Prost Stabels Vei 22 | 2019 Skedsmokorset | Norway | [email protected]

Norsk Elektro Optikk AS (NEO) was established in 1985 as a privately owned research company within the field of electro optics. The founders had their scientific and technical background from the Norwegian Defense Research Establishment, which for the last 30-40 years have been the leading research organization in electro optics in Norway. The company has grown to be the largest independent research and development organization in electro optics in Norway, and has

established itself as a reputed manufacturer of advanced electro optical products. NEO is certified to the ISO 9001:2008 international quality standards.

The hyperspectral imaging activities at NEO started in 1995 with the HISS (Hyperspectral Imager for Small Satellites) project for ESA. The R&D activities in hyperspectral imaging have been internally funded through commercialization of the technology together with participation in several EU projects, as well as projects funded by the Ministry of Defense, the Norwegian Research Council etc.

Over the years, HySpex has established itself as one of the world’s leading brands for both airborne and ground based hyperspectral imaging. HySpex sensors are renowned for their stability, flexibility and superior data quality.

NEO and NEO Monitors are collocated at Prost Stabels Vei 22.

HySpex false color RGB data preview (selected bands R:550nm, G:1620nm, B:1250nm).

2500 nm

Tree

Sample radiance spectra from the image below.

Tennis court

Lawn

1000 nm400 nm

0.10

0.05

Sample radiance spectra from the image above.

HySpex false color RGB data preview (selected bands R:550nm, G:1620nm, B:1250nm).

About

Page 5: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

5

All HySpex cameras undergo rigorous testing and characterization during production. The tests are documented in an elaborate test report for each camera, identifying both the test procedures and results.

Transparency in the calibration and testing procedures is key to provide the end-user with an overview of performance parameters that are crucial to the quality of the system, but not necessarily communicable on a top-level datasheet.

Pushbroom imagers All HySpex cameras are pushbroom hyperspectral imagers. When acquiring data, the camera captures all spectral information simultaneously from a narrow line of the spatial scene. As the camera is scanned across the scene or vice versa, the spatial scene is captured and added to the hyperspectral cube. The output data product thus contains both a spatial scene together with the contiguous spectral information from each pixel in the spatial scene. HySpex cameras can be supplied as turn-key acquisition solutions, allowing the user to acquire scientific-grade quality data immediately after delivery. Key quality parametersAll HySpex cameras provide scientific-grade data quality. To be classified as a scientific-grade imager, the camera should as a minimum document having:

- Good SNR for all specified wavelengths - Low spectral and spatial distortions per pixel and band - Sharp optic relative to a pixel - Low F# optics - Low noise floor and high full well detector - Traceable calibration- Robust, stable and repeatable system

HySpex cameras used for mineface scanning from UAV(left), field operations (middle), and close range phenotyping lab (right).

Data Quality

Page 6: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

6

HySpex Classic

HySpex Classic cameras are designed to be application-generic and can be used at a wide range of platforms. The optics are made for specific high-end detectors and are very sharp per pixel and band, and are designed to minimize optical distortions such as smile and keystone down to 10% of a pixel over the full spectral and spatial range covered by the camera. Also, the spatial and spectral resolution is optimized to be as similar as possible for all points in the FOV and all spectral bands. HySpex classic cameras are the most flexible cameras, offering exceptional spectral integrity per pixel for all applications. All HySpex cameras are delivered with calibration traceable to NIST and PTB standards. Nyquist camerasIn contrast to a camera designed to be as sharp as possible, cameras can be designed to sample the point spread function (PSF) with more than one pixel.

To distinguish the camera designs, HySpex has added an “N” to the model name when approaching 2 bands Full-Width-Half-Max (FWHM) of the PSF in the spectral direction. The N indicates that the system has close to Nyquist sampled PSF spectrally. A Nyquist camera will be able to reproduce the actual spectrum, avoiding spectral aliasing.

Page 7: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

7

Standard configurations for HySpex Classic

Airborne ApplicationsHigh resolution and high speed, combined with low weight and power consumption, make HySpex cameras very well suited for airborne data acquisition.A typical airborne installation consists of the HySpex cameras coupled with an airborne data acquisition unit, a navigation system (IMU/GPS) and a mount-ing platform. Both actively stabilized and passive-ly damped mounting platforms can be supplied, as well as standard mounting plates with no damping. IMU/GPS solutions from leading manufacturers can be supplied and integrated with the cameras.Alternatively, HySpex systems can be interfaced with the customer’s existing navigational hardware.

Laboratory SetupFor lab and field use, a scanning stage is needed to scan the cameras and build the hyperspectral data cube of the scene. A user-friendly table-top lab setup with translation stage, VNIR-SWIR light sources, and close-up lenses can also be supplied for scanning of samples of varying sizes. The scan-ning speed is automatically controlled by the data acquisition unit, based on the selected lens option. The lab rack includes a camera adjustment platform, to facilitate camera focus adjustment when using different close-up lenses.

Field SetupFor field operations, NEO supplies a range of high precision rotation stages tailored to fit the number of cameras and the operational scheme is supplied. Long-life Li-ion battery powered solutions are available for increased portability. To ensure stable and reliable acquisitions in challenging field conditions, rugged and portable tripods are supplied. NEO supplies a variety of tripods with pan/tilt heads that will accommodate the payload of the cameras and rotation stage used.

Page 8: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

8

HySpex VNIR-1024

The HySpex VNIR-1024 hyperspectral camera is developed for field, laboratory, and airborne applications. HySpex VNIR-1024 combines extreme acquisition speeds with no compromise on the data quality. The high frame rate makes VNIR-1024 an ideal camera for low altitude flights or other applications where high frame rates and high radiometric accuracy is required. Like all HySpex cameras, HySpex VNIR-1024 is rigorously tested and calibrated to traceable standards during production. A wide range of close-up lenses allows the use of the camera at working distances ranging from a few centimeters with a spatial resolution of 42 μm, to infinity e.g. airborne remote sensing.

MAIN SPECIFICATIONS

Spectral range 400-1000 nm

Spatial pixels 1024

Spectral channels 108

Spectral sampling 5.4 nm

FOV* 16.1°

Pixel FOV across/along* 0.28/.0.56 mrad

Bit resolution 14 bit

Noise floor 11 e-

Dynamic range 3400

Peak SNR (at full resolution) > 330

Max speed (at full resolution) 690 fps

Power consumption 6 W

Dimensions (l-w-h) 30.5-9.9-15 cm

Weight 4.2 kg

Camera Interface CameraLink

*Can be doubled with FOV expander

Page 9: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

9

HySpex VNIR-1800

The HySpex VNIR-1800 hyperspectral camera is developed for field, laboratory, and airborne appli-cations. HySpex VNIR-1800 utilizes a cutting edge actively cooled and stabilized scientific CMOS detector. This makes VNIR-1800 the ideal camera for high-end data acquisitions where high radiometric accuracy is required. The dynamic range of 20 000 ensures outstanding SNR levels even in darker areas of an image of highly dynamic scenes. With a max frame rate of 260 fps, combined with aberration- corrected optics and high optical throughput (f/2.5), HySpex VNIR-1800 offers a unique combination of data quality, high speed, and sensitivity. A wide range of close-up lenses allows the use of the camera at working distances ranging from a few centimeters with a spatial resolution of 24 μm, to infinity e.g. airborne remote sensing.

MAIN SPECIFICATIONS

Spectral range 400 – 1000 nm

Spatial pixels 1800

Spectral channels 186

Spectral sampling 3.26 nm

FOV* 17°

Pixel FOV across/along* 0.16/0.32 mrad

Bit resolution 16 bit

Noise floor 2.4 e -

Dynamic range 20000

Peak SNR (at full resolution) > 255

Max speed (at full resolution) 260 fps

Power consumption 30 W

Dimensions (l–w–h) 39 – 9.9 – 15 cm

Weight 5.0 kg

Camera Interface CameraLink

*Can be doubled with FOV expander

Page 10: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

10

HySpex VNIR-3000N

HySpex VNIR-3000N is developed for field, laboratory, and airborne applications. HySpex VNIR-3000N utilizes the same spectrograph as the other classical HySpex VNIR models. With a pixel size of 3.45µm, compared to 6. 5µm for VNIR-1800, HySpex VNIR-3000N will have less than 1.6 pixels per FWHM of the PSF spatially and less than 1.8 bands spectrally, ensuring that narrow band features will be resolved equally for all cameras. With 3000 spatial pixels, 300 bands and a noise floor of 2.4e-, HySpex VNIR-3000N will provide outstanding SNR levels in dark environments. The camera is offered with a USB connection, allowing you to operate the camera from any computer and reducing the cost of supplementing equipment. To visualize that the camera has a wider PSF per pixel and band relative to our normal extremely sharp cameras, we have added an N for Nyquist to the model name.

MAIN SPECIFICATIONS

Spectral range 400-1000 nm

Spatial pixels 3000

Spectral channels 300

Spectral sampling 2.0 nm

FOV* 16°

Pixel FOV across/along* 0.096/0.32 mrad

Bit resolution 12 bit

Noise floor 2.37 e-

Dynamic range 11000

Peak SNR (at full resolution) > 170

Max speed (at full resolution) 117 fps

Power consumption 30 W

Dimensions (l–w–h) 39 – 9.9– 15 cm

Weight 5.0 kg

Camera Interface USB3

*Can be doubled with FOV expander

Page 11: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

11

HySpex SWIR-384

The HySpex SWIR-384 hyperspectral camera is developed for field, laboratory, and airborne applications. The state of the art MCT sensor with cooling down to 150K yields low background noise, high dynamic range, and exceptional SNR levels. With a max frame rate of 400 fps, combined with an aberration-corrected optical system with high optical throughput (f/2), the data quality, speed and sensitivi-ty is truly state of the art.

A wide range of close-up lenses allows the use of the camera at working distances ranging from a few centimeters with a spatial resolution of 53 μm to infinity e.g. airborne remote sensing.

MAIN SPECIFICATIONS

Spectral range 930-2500 nm

Spatial pixels 384

Spectral channels 288

Spectral sampling 5.45 nm

FOV* 16°

Pixel FOV across/along* 0.73/0.73 mrad

Bit resolution 16 bit

Noise floor 150 e-

Dynamic range 7500

Peak SNR (at full resolution) > 1100

Max speed (at full resolution) 400 fps

Power consumption 30 W

Dimensions (l–w–h) 38 – 12– 17.5 cm

Weight 5.7 kg

Camera Interface CameraLink

*Can be doubled with FOV expander

Page 12: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

12

Page 13: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

13

Page 14: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

14

The Viking Era: Mjolnir

Contracted by the Norwegian and French Ministry of Defense, NEO designed a high-end airborne hyperspectral sensor, with an optical architecture different from the classic cameras. Upon completion of the project, NEO used the optical architecture to develop Mjolnir – a very compact camera designed specifically for UAV use.

The HySpex Mjolnir hyperspectral imaging system for UAVs provides a unique combination of small form factor and low mass, combined with high-performance specifications and scientific grade data quality. The UAV bundle offered by NEO integrates a hyperspectral camera with an onboard computer and an integrated navigation system, all fitted into a self-contained module. Being operationally fully independent of the UAV, HySpex Mjolnir cameras are designed to be compatible with a wide range of UAVs. APX-15 and APX-20 support dual IMU which is especially important when operating with the gimbal to compensate for the dynamic lever arm.

Page 15: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

15

UAV Configuration

UAV - BFD XQ-1400S

HySpex can be mounted on any UAV platform capable of lifting the total payload.• BFD XQ-1400S provides ~30 min. flight

endurance with Mjolnir payload• Ground control software for advanced flight plans• High stability in wind

GIMBAL

The advanced 3-axis digital stabilizer, gStabi H16, weighs only 2.2 kg (4.85 lbs). NEO delivers the gStabi H16 with a circular quick release, allowing it to be seamlessly fit on a wide range of multi-rotors. Capable of handling payloads up to 7 kg (15.43 lbs), the gimbal can support all HySpex Mjolnir models.• Gimbal and Mjolnir powered by same battery• Encoder with resolution up to 0.005°• Ultra accurate IMU sensor with temperature

compensation

APPLANIX APX-15/20 UAV

• Advanced Applanix IN-FusionTM GNSS-Inertial integration technology

• 100 Hz real-time position, roll, pitch and heading output for direct georeferencing of sensor data

• IMU data rate 200 Hz• 336 Channels (GPS, GLONASS, BeiDou,

Galileo, QZSS, SBAS)• Solid-state MEMS inertial sensors w/Applanix

SmartCalTM compensation technology• Unfiltered, unsmoothed pseudo-range

measurements data for low noise, low multipath error, low time domain correlation and high dynamic response

Ground ConfigurationAll Mjolnir systems can easily be deployed for fieldwork by mounting it on a tripod with a rotation stage.• Lightweight, robust, compact and

self-contained design• Working distances: 20 m – • Can be fully battery powered• Quick mounting and easy operation with scan

speed fully synchronized with camera frame rate• Easy wireless operation from tablet or laptopA 1m close-up lens is also available for closer range ground measurements.

Page 16: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

16

HySpex Mjolnir V-1240

The HySpex Mjolnir V-1240 hyperspectral imaging system for UAVs provides a unique combination of small form factor and low mass, combined with high-performance specifications and scientific grade data quality.

With a weight of less than 4 kg and less than 50 W power consumption, HySpex Mjolnir V-1240 is very well suited for a wide range of UAVs.

The system is also compatible with several off-the-shelf gimbals. NEO offers high-performance unmanned aerial vehicles, fully integrated with the HySpex Mjolnir V-1240. The UAV is fitted with a standard battery package allowing up to 30 minutes of flight time. All HySpex Mjolnir systems can also be mounted on a tripod and rotation stage for ground use.

MAIN SPECIFICATIONS

Spectral range 400 – 1000 nm

Spatial pixels 1240

Spectral channels and sampling 200 bands @ 3 nm

F-number F1.8

FOV 20°

Pixel FOV across/along 0.27/0.27 mrad

Bit resolution 12 bit

Noise floor 2.3 e -

Dynamic range 4400

Peak SNR (at full resolution) > 180

Max speed (at full resolution) 285 fps

Power consumption 50 W

Dimensions (l–w–h) 250 – 175 – 170 mm

Weight < 4 kg

*Includes IMU/GPS and DAU – <6.5 kg including standard battery

Page 17: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

17

HySpex Mjolnir S-620

The HySpex Mjolnir S-620 hyperspectral imaging system for UAVs is the SWIR version of the Mjolnir camera series. Similar to the VNIR version, it provides a unique combination of small form factor and low mass, combined with high-performance specifications and scientific grade data quality.

With a weight of less than 4.5 kg and less than 50 W power consumption, HySpex Mjolnir S-620 is very well suited for a wide range of UAVs.

NEO offers high-performance unmanned aerial vehicles, fully integrated with the HySpex Mjolnir S-620. The UAV is fitted with a standard battery package allowing up to 30 minutes of flight time. All HySpex Mjolnir systems can also be mounted on a tripod and rotation stage for ground use.

MAIN SPECIFICATIONS

Spectral range 970 – 2500 nm

Spatial pixels 620

Spectral channels and sampling 300 bands @ 5.1 nm

F-number F1.9

FOV 20°

Pixel FOV across/along 0.54/0.54 mrad

Bit resolution 16 bit

Noise floor 80 e -

Dynamic range 10000

Peak SNR (at full resolution) > 900

Max speed (at full resolution) 100 fps

Power consumption* 50 W

Dimensions (l–w–h)* 254 – 175 – 170 mm

Weight* < 4.5 kg

*Includes IMU/GPS and DAU – <5 kg including standard battery

Page 18: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

18

HySpex Mjolnir VS-620

For applications requiring low mass, combined with high-performance specifications and scientific grade data quality on the full VNIR-SWIR range, HySpex Mjolnir VS-620 is an ideal solution. Sharing the on-board data acquisition unit and navigation system, HySpex Mjolnir VS-620 is both space-efficient and cost-effective.

The VNIR and SWIR optical axis are coaligned in the along track direction, assuring perfect coregistration in the flight direction. In addition to the high-quality hyperspectral data cube, covering the spectral range from 400 - 2500 nm, with 490 bands, double resolution data in the VNIR range is always readily available. With smile and keystone less than 0.1 pixels for each spectral range, the merged Mjolnir VS-620 data product will have coregistration/keystone better than 0.2 pixels for the full VNIR-SWIR range.

MAIN SPECIFICATIONS V-1240 S-620

Spectral range 400 – 1000 nm 970 – 2500 nm

Combined spectral range 400 – 2500

Spatial pixels 1240 620

Combined spatial pixels 620

Spectral channels and sampling 200 bands @ 3.0 nm 300 bands @ 5.1 nm

Combined spectral channels 490

F-number F1.8 F1.9

FOV 20° 20°

Combined FOV 20°

Pixel FOV across/along 0.27/0.54 mrad 0.54/0.54 mrad

Combined Pixel FOV across/along 0.54/0.54 mrad

Bit resolution (raw data) 12 bit 16 bit

Noise floor 2.3 e - 80 e -

Dynamic range 4400 10000

Peak SNR (at full resolution) > 180 > 900

Max speed (at full resolution) 285 fps 100 fps

Power consumption* 50 W

Dimensions (l–w–h)* 374 – 202 – 178 mm

Weight* ~ 6 kg

*Includes IMU/GPS and DAU – <6.5 kg including standard battery

Page 19: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

Baldur V-1024 N at the Lerøy fillet facility in Båtsfjord, Norway

Page 20: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

20

Industrial Baldur

Designed to be fast, flexible, robust and repeatable, HySpex offers the Baldur line of industrial cameras. Baldur utilizes the same optical design as the classic systems, with some modifications. All Baldur cam-eras are Nyquist cameras giving a spectral resolution of 2 spectral bands while capturing 4 times as much light as the classic systems. To ensure that the most information per framerate is provided, the spectral resolution is kept very close to 2 bands. Additionally, the spatial resolution is better than 1.7 pixels for all Baldur models, yielding very sharp cameras, albeit not to the extremes of the classic and Mjolnir cameras.

Baldur benefits• Flexibility: All Baldur cameras support multiple regions of interest (MOI). • Trigger: All camera can be triggered internally, and all cameras support several kinds external triggering.

All cameras are operating in Integrate While Read (IWR) mode.• Speed: Maximized information per data rate of any hyperspectral camera. Speed scalable with reducing

the number of spectral channel read-out. • Reliability and traceability:

All cameras delivered with traceable calibration to NIST and PTB standards. All cameras within the same wavelength range have the same center wavelengths. Well-proven and robust design.

• Light sensitivity: High speed acquisitions with light sensitivity 4 times higher than HySpex classic. • SDK: All HySpex cameras (Baldur, Classic and Mjolnir) are delivered with a high-end SDK and library

that makes it simple to integrate the HySpex HW into any third-party software and hardware solution. • Fully integrated hardware and software solution

Third-party software Through being a shareholder in Prediktera, HySpex can offer seamless integration of HW and data processing SW, providing their users with unparalleled capability not only to collect high quality data, but also bridge the gap between hyperspectral data and end-user results. This will prove to be especially effective for industrial applications that require real-time detection. Together we can offer: • Turnkey HW and SW solution for easy and quick test and development of operational algorithms/models. • High-end hyperspectral cameras for R&D with toolbox to resize data and spectrally optimize

for an industrial application. • Runtime engine for real time processing with CPU and GPU computing support, allowing real-time

processing of data from all cameras at max acquisition speed. • Easy export from offline SW package to the runtime engine. • Connector Software to interface with the customer’s graders, sorters or similar. HySpex is compatible and open to collaborating with all third-party processing software suppliers on the market.

Page 21: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

21

HySpex Baldur V-1024 N

Designed to be fast, flexible, robust and repeatable, HySpex offers the Baldur line of industrial cameras.

Baldur V-1024 N covers the full VNIR spectral range from 400-1000nm and is configurable within one octave in the same range.

All Baldur cameras are Nyquist cameras giving a spectral resolution of 2 spectral bands while capturing 4 times as much light as the classic systems. To ensure that the most information per framerate is provided, the spectral resolution is kept very close to 2 bands. Additionally, the spatial resolution of Baldur V-1024 N is better than 1.7 pixels, yielding a very sharp camera.

MAIN SPECIFICATIONS

Spectral Range 400-800/430-820/485-960/400-1000 nm

Spectral bands 72/72/88

Max speed* 1000/1000/800

Spectral sampling 5.5 nm

Spectral FWHM <2 bands

Spatial FWHM < 1.7 pixels

Spatial pixels 1024

Keystone <15% of a pixel

Smile <15% of band

FOV 16° / 40°

Bit resolution 12

Noise floor 11e

Peak SNR >286

Dynamic range 2560

ROI* 8 independent ROIs

Dimensions (l-w-h) 316 – 105 – 153 mm

On-scene scan speed for various aperture options V-1024N

Working distance

Field of View Pixel size Max speed (91 bands*)

Max speed (45 bands*)

1.0 m 16°/293 mm 0.286 mm 0.22 m/s 0.44 m/s

1.0 m 40°/748 mm 0.730 mm 0.56 m/s 1.12 m/s

1.9 m 40°/1331 mm 1.300 mm 1.00 m/s 2.00 m/s

* Reducing the number of spectral channels with ROI will proportionally increase the max framerate

* With square pixels. Reducing the number of spectral channels with ROI will proportionally increase the max framerate.

Page 22: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

22

HySpex Baldur S-640i N

Designed to be fast, flexible, robust and repeatable, HySpex offers the Baldur line of industrial cameras.

Baldur S-640i N covers the spectral range from 950-1730nm.

All Baldur cameras are Nyquist cameras giving a spectral resolution of 2 spectral bands while capturing 4 times as much light as the classic systems. To ensure that the most information per framerate is provided, the spectral resolution is kept very close to 2 bands. Additionally, the spatial resolution of Baldur S-640i N is better than 1.5 pixels, yielding a very sharp camera.

MAIN SPECIFICATIONS

Spectral Range 950-1730 nm

Spectral bands 232

Max speed* 500 fps

Spectral sampling 3.36 nm

Spectral FWHM <2 bands

Spatial FWHM <1.5 pixels

Spatial pixels 640

Keystone <20% of a pixel

Smile <20% of band

FOV 16° / 40°

Bit resolution 12 bit

Noise floor HG:8.5/MG:32/LG:270 e-

Peak SNR HG:150/MG:275/LG:800

Dynamic range HG:2650/MG:2360/LG:2360

ROI* All bands can be selected/deselected individually

External trigger options LVDS, 5V/12V/24V TTL

Dimensions (l-w-h) 364 – 105 – 153 mm

On scene scan speed for various aperture options

Working distance

Field of View Pixel size Max speed (232 bands*)

Max speed(116 bands*)

1.0 m 16°/282 mm 0.44 mm 0.22 m/s 0.40 m/s

1.0 m 40°/704 mm 1.10 mm 0.55 m/s 1.10 m/s

1.9 m 40°/1344 mm 2.10 mm 1.05 m/s 4.20 m/s

* Reducing the number of spectral channels with ROI will proportionally increase the max framerate

* With square pixels. Reducing the number of spectral channels with ROI will proportionally increase the max framerate.

Page 23: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

23

HySpex Baldur S-384 N

Designed to be fast, flexible, robust and repeatable, HySpex offers the Baldur line of industrial cameras.

Baldur S-384 N is configurable within one octave in the SWIR spectral range from 950-2500nm.

All Baldur cameras are Nyquist cameras giving a spectral resolution of 2 spectral bands while capturing 4 times as much light as the classic systems. To ensure that the most information per framerate is provided, the spectral resolution is kept very close to 2 bands. Additionally, the spatial resolution of Baldur S-384 N is better than 1.3 pixels, yielding a very sharp camera.

MAIN SPECIFICATIONS

Spectral Range 960-1920/1100-2200/1250-2500nm

Spectral bands 178/204/231

Max speed* 650/564/500 fps

Spectral sampling 5.45nm

Spectral FWHM <2 bands

Spatial FWHM < 1.3 pixels

Spatial pixels 384

Keystone <15% of a pixel

Smile <15% of band

FOV 16° / 40°

Bit resolution 16

Noise floor 150 e

Peak SNR 7500

Dynamic range 2560

ROI* All bands can be selected/deselected individually

External trigger options LVDS, 5V/12V/24V TTL

Dimensions (l-w-h) 368 – 131 – 175 mm

On scene scan speed for various aperture options S-384N

Working distance

Field of View Pixel size Max speed (200 bands*)

Max speed (100 bands*)

1.0 m 16°/280 mm 0.73 mm 0.42 m/s 0.84 m/s

1.0 m 40°/699 mm 1.82 mm 1.05 m/s 2.10 m/s

1.9 m 40°/1344 mm 3.50 mm 2.02 m/s 4.03 m/s

* Reducing the number of spectral channels with ROI will proportionally increase the max framerate

* With square pixels. Reducing the number of spectral channels with ROI will proportionally increase the max framerate.

Page 24: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

24

VNIR-1024 VNIR-1800 VNIR-3000N SWIR-384

Spectral range [nm] 400-1000 400 – 1000 400-1000 930-2500

Spatial pixels 1024 1800 3000 384

Spectral channels 108 186 300 288

Spectral sampling [nm] 5.4 3.26 2.0 5.45

FOV* 16.1° 17° 16° 16°

Pixel FOV across/along [mrad]* 0.28/.0.56 0.16/0.32 0.096/0.32 0.73/0.73

Bit resolution 14 bit 16 bit 12 bit 16 bit

Noise floor 11 e- 2.4 e - 2.37 e- 150 e-

Dynamic range 3400 20000 11000 7500

Peak SNR (at full resolution)

> 330 > 255 > 170 > 1100

Max speed (at full resolution)

690 fps 260 fps 117 fps 400 fps

Power consumption 6 W 30 W 30 W 30 W

Dimensions (l-w-h) [mm] 305 - 99 - 150 390 - 99 - 150 390 - 99 - 150 380 - 120 - 175

Weight 4.2 kg 5.0 kg 5.0 kg 5.7 kg

Camera Interface CameraLink CameraLink USB3 CameraLink

HySpex Classic

HySpex Classic cameras are designed to be application-generic and will be used at a wide range of platforms. The optics are made for specific high-end detectors and are extremely sharp per pixel and band, and are designed to minimize optical distortions such as smile and keystone down to 10% of a pixel over the full spectral and spatial range covered by the camera. Also, the spatial and spectral resolution remove is optimized to be as similar as possible for all points in the FOV and all spectral bands. HySpex classic cameras are the most flexible cameras, offering exceptional spectral integrity per pixel for all applications.

All HySpex cameras are delivered with calibration traceable to NIST and PTB standards.

*Can be double with FOV expander

Page 25: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

25

V-1240 S-620 VS-620

Spectral range [nm] 400-1000 970-2500 400-2500

Spatial pixels 1240 620 620

Spectral channels 200 300 490

Spectral sampling [nm] 3.0 5.1 3.0 5.1

Field of View 20° 20° 20°

Pixel FOV across/along [mrad] 0.27/0.27 0.54/0.54 0.54/0.54

Bit resolution 12 bit 16 bit 16 bit

Noise floor 2.3 e- 80 e- 2.3 e- 80 e-

Dynamic range 4400 10000 4400 10000

Peak SNR (at full resolution) > 180 > 900 > 180 > 900

Max speed (at full resolution) 285 fps 100 fps 100 fps

Power consumption* 50 W 50 W 50 W

Dimensions (l-w-h) [mm]* 250-175-170 365-175-170 374-202-178

Weight* < 4 kg < 4.5 kg < 6.0

HySpex Mjolnir

Contracted by the Norwegian and French Minis-try of Defense, NEO designed a high-end airborne hyperspectral sensor, with an optical architecture different from the classic cameras. Upon completion of the project, NEO used the optical architecture to develop Mjolnir – a very compact camera designed specifically for UAV use.

The HySpex Mjolnir hyperspectral imaging system for UAVs provides a unique combination of small form factor and low mass, combined with high- performance specifications and scientific grade data quality. The UAV bundle offered by NEO integrates a hyperspectral camera with an onboard computer and an integrated navigation system, all fitted into a self-contained module.

*Includes IMU/GPS and DAU

Page 26: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

26

V-1024 N S-640i N S-384 N

Spectral Range [nm] 400-800/430-820/485-960/400-1000

950-1730 960-1920/1100-2200/1250-2500

Spectral bands 72/72/88 232 178/204/231

Max speed* 1000/1000/800 500 650/564/500 fps

Spectral sampling [nm] 5.5 3.36 5.45

Spectral FWHM <2 bands <2 bands <2 bands

Spatial FWHM < 1.7 pixels <1.5 pixels < 1.3 pixels

Spatial pixels 1024 640 384

Keystone <15% of a pixel <20% of a pixel <15% of a pixel

Smile <15% of band <20% of band <15% of band

FOV 16° / 40° 16° / 40° 16° / 40°

Bit resolution 12 12 16

Noise floor [e-] 11 HG:8.5/MG:32/LG:270 150

Peak SNR >286 HG:150/MG:275/LG:800 7500

Dynamic range 2560 HG:2650/MG:2360/LG:2360

2560

ROI* 8 independent ROIs All bands can be selected/deselected

individually

All bands can be selected/deselected

individually

External trigger options LVDS, 5V/12V/24V TTL LVDS, 5V/12V/24V TTL

Dimensions (l-w-h) [mm] 316 – 105 – 153 364 – 105 – 153 368 – 131 – 175

Camera Interface CameraLink GigE CameraLink

HySpex Baldur

Designed to be fast, flexible, robust and repeatable, HySpex offers the Baldur line of industrial cameras.

All Baldur cameras are Nyquist cameras giving a spectral resolution of 2 spectral bands while capturing 4 times as much light as the classic systems. To ensure that the most information per framerate is provided, the spectral resolution is kept very close to 2 bands. Additionally, the spatial resolution better than 1.7 pixels for all Baldur cameras, yielding very sharp cameras.

* Reducing the number of spectral channels with ROI will proportionally increase the max framerate

Page 27: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

27

Contact us

HeadquartersNorsk Elektro Optikk AS

Prost Stabels vei 22

2019 Skedsmokorset, Norway

Phone: + 47 40 00 18 58

www.hyspex.com

HySpex Inc.HySpex Inc.

65 Plain Street

Clinton, MA 01510, U.S.A.

Phone: +1 (954) 270-0132

https://www.linkedin.com/company/neo-hyspex

https://www.instagram.com/hyspex

Page 28: Contentmesure.optoprim.com/.../uploads/2016/04/Hyspex_brochure.pdf · 2019-10-10 · 0.05 Sample radiance spectra from the image above. ... delivered with calibration traceable to

28

Norsk Elektro Optikk AS ⁄ Prost Stabels vei 22, 2019 Skedsmokorset, Norway ⁄ www.hyspex.com