· 2019-04-14 · for inquires or orders : safety warnings : please read the "safety...
TRANSCRIPT
For inquires or orders :
Safety Warnings :Please read the "Safety Warnings" in the instruction manual supplied with the instrument thoroughly and completely for correct use. Failure to follow the safety rules can cause fire, trouble, electrical shock, etc. Therefore, make sure to operate the instrument on a correct power supply and voltage rating marked on each instrument.
The contents of this leaflet are subject to change without notice.In consideration of the environment, soy ink and recycled paper were used in this publication. GeneCata13-14_1E May 13 AD
China
Japan
Thailand
Headquarters
Affiliates
U.K. Italy
KYORITSU GLOBAL NETWORK
Kew (Thailand) Ltd.
Navanakorn Industrial Estate60/48, Moo 19,Klongluang,Pathumthani, 12120 ThailandPhone: +66-2-529-0542~4 FAX: +66-2-529-0541
Kewtech Corporation Ltd.
Midas House, Unit 2b Stones Courtyard, High Street, Chesham, Buckinghamshire, HP5 1DE, EnglandPhone: +44-1494-792212 FAX: +44-1494-791826
Kew Europe Office
Viale Rimembranze 93/18, 20099 Sesto S. Giovanni (MI) ItalyPhone: +39-02-38238685
KYORITSU SHANGHAI TRADING COMPANY LIMITED
Room1303, No.58 Yan'an East Road,Huangpu District, Shanghai 200002, ChinaPhone: +86-21-6321-8899 FAX: +86-21-5015-2015URL: http://www.kew-ltd.com.cnE-mail: [email protected]
KYORITSU ELECTRICAL INSTRUMENTS WORKS, LTD.
No.5-20, Nakane 2-chome, Meguro-ku, Tokyo, 152-0031 JapanPhone: +81-3-3723-0131FAX: +81-3-3723-0152URL: http://www.kew-ltd.co.jpE-mail: [email protected]: Ehime
Test and Measuring Instruments Catalogue 2013~14
Cat
alo
gu
e 2013~14
KEW2500
KEW4202
KEW6305
P24
P56
P41
DC MILLIAMP CLAMP METER
POWER METER
EARTH CLAMP METER
Measures DC 4-20mA signalswithout breaking the loop
Compact Power meter forcost saving through Energymonitoring
Easy Earth /ground resistancemeasurement just clamp-on conductorWireless communication withAndroid application
NEW
NEW
NEW
Please read the “Safety Warnings” in the instruction manual supplied with the instrument thoroughly and completely for safety use. Failure to follow the safety rules can cause fire, trouble, electrical shock, etc. Therefore, make sure to operate the instrument on a correct power supply and voltage rating marked on each instrument.
Safety Warnings
CONTENTS1109S, 1110 ............................................................ 101009, 1011, 1012 ................................................... 111018, 1018H, 1030 ................................................ 122000, 2001, 2012R ................................................ 131051, 1052, 1061, 1062 ........................................ 14
6201A, 6202 .........................................................55
Test Leads ................................................................68
Instrument Glossary ................................................73Symbols List .............................................................75Product Index .......................................................... 76Kyoritsu Quality Control Concept ............................79
Line Up ...................................................................... 4Application ................................................................ 6
KT200, KT203 ........................................................66KT170, KT171 .........................................................67
5201, 5202, 5510 ..................................................648030, 8031,8031F, 8035 ......................................65
8309, 8325F ..........................................................608124, 8125, 8126, 8127, 8128, 8129 .................... 618121, 8122, 8123, 8146, 8147, 8148 ....................628115, 8141, 8142, 8143 .........................................63
6305 .......................................................................566310 .......................................................................58
6010B .....................................................................506010A, 6011A ........................................................ 516016........................................................................526018, 6050.............................................................54
5001 .......................................................................465010, 5020 ............................................................48
4118A .....................................................................424140 .......................................................................435402D, 5406A .......................................................445410........................................................................45
4102A, 4105A ........................................................394106, 4300 ............................................................404200, 4202 ............................................................ 41
3001B, 3005A, 3007A ..........................................303021, 3022, 3023 ................................................. 313131A, 3132A ........................................................32
3161A, 3165, 3166, 3321A ...................................333121A, 3122A, 3123A, 3124 ................................343125, 3126 .............................................................353128........................................................................36
2608A, 2805 ......................................................... 192007A .................................................................... 192002PA, 2002R, 2017, 2027 .................................202031, 2040, 2200 .................................................. 212003A, 2009R, 2010 .............................................222033, 2046R, 2055, 2056R ..................................232500 .......................................................................24
2300R .....................................................................242431, 2432, 2433, 2433R.....................................252412, 2413F, 2413R, 2434 ....................................268115, 8112, 8112BNC .............................................27
8008 .......................................................................27
PORTABLE APPLIANCE TESTERS
ACCESSORIES
KEWTECH
OTHERS
SENSORS
POWER METERS
MULTI FUNCTION TESTERS
LOGGERS
MULTIMETERS ANALOGUE MULTIMETERS
DIGITAL MULTIMETERS
LOOP/PSC/RCDTESTERS LOOP/PSC TESTERS
RCD TESTERS
EARTH TESTERS EARTH TESTERS
EARTH CLAMP TESTERS
INSULATION TESTERS DIGITAL INSULATION/CONTINUITY TESTERS
ANALOGUE INSULATION/CONTINUITY TESTERSANALOGUE INSULATION TESTERS
HIGH VOLTAGE INSULATION TESTERS
CLAMP METERS ANALOGUE CLAMP METERS
DIGITAL CLAMP METERS
DC MILLIAMP CLAMP METERFORK CURRENT TESTER
LEAKAGE CLAMP METERS
CLAMP SENSOR/CLAMP ADAPTORMULTI-TRAN
φ24 MAXAC 200Aφ33 MAX
AC 600ARMS
φ33 MAXAC 600Aφ33 MAX
AC 600A
•2002R
φ55 MAXAC2000A
KYORITSU LINE UP
NEW
NEW
NEW
4
ANALOGUE MULTIMETERS
ANALOGUE INSULATION/CONTINUITY TESTERS
EARTH TESTERS LOOP/PSC TESTERS RCD
OTHERS
DIGITAL CLAMP METERS
LEAKAGE
DIGITAL MULTIMETERS
DIGITAL CLAMP METERS
EARTH CLAMP TESTER
ANALOGUE INSULATION DIGITAL INSULATION/CONTINUITY TESTERS
PORTABLE APPLIANCE TESTERSMULTI FUNCTION TESTERS POWER METERS
DIGITAL MULTIMETERS
P23
P30
P39
P52 P54 P54 P55P55 P58 P64P56
P39 P40 P41P40 P42 P43 P44
P31 P32 P32 P33 P33
P23 P26P24P24 P26
P19 P20 P20 P21
P10 P11 P12 P12P11P10
P20
KEW 1109S MODEL 1110 MODEL 1009 KEW 1018/1018H
MODEL 2007A MODEL 2017 MODEL 2027 MODEL 2031
MODEL 2412MODEL 2300RKEW 2500 KEW 2413F
MODEL 4102A MODEL 4105A MODEL 4200 KEW 4202
KEW 4300 MODEL 4118A KEW 4140 MODEL 5402D
KEW 6016 MODEL 6018 MODEL 6050 (LOOP+RCD) MODEL6202KEW 6201A KEW 6310KEW 6305 MODEL 5201
KEW 1030
KEW 2046R KEW 2055/2056R
KEW 1011/1012
KEW 2413R
KEW 4106
MODEL 2002PAMODEL 2002R
MODEL 3007A MODEL 3131A MODEL 3132A MODEL 3161A MODEL 3165/3166
3131A(250V/500V/1000V) 3132A(250V/500V/1000V) 3161A(15V/500V)3165(500V) 3166(1000V)3007A(250V/500V/1000V)
KEW 3021~3023
3021(125V/250V/500V/1000V)3022(50V/100V/250V/500V)3023(100V/250V/500V/1000V)
φ68 MAXAC1000A
• 2413R
φ40 MAXAC 500Aφ10 MAX
AC/DC 100ARMS
φ40 MAXAC/DC 1000A
• 2056R
φ33RMS
MAXAC/DC 600A
• 1012
φ6
RMS
RMS
RMS
RMS
www.kew-ltd.co.jp
φ40 MAXAC 100Aφ24 MAX
AC 200A
φ33 MAXAC1000A
φ30
MAXAC 400A
KYORITSU LINE UP
NEW
5
ANALOGUE CLAMP METERS
DIGITAL CLAMP METERS
DIGITAL INSULATION/CONTINUITY TESTERS
TESTERS
CLAMP METERS
HIGH VOLTAGE INSULATION TESTERS
MULTI FUNCTION TESTERS
OTHERS KEWTECH
LOGGERSTESTERS
DIGITAL MULTIMETERS
P64 P64 P65 P65 P67 P66P65P65
P44 P45 P46 P48 P51 P50 P51
P33 P34 P34 P35 P35 P36
P25 P25 P25 P26 P30 P30
P13 P19P13 P19
P21 P21 P22 P22 P22 P23
P14 P14
MODEL 2608A MODEL 2805
KEW 2009R MODEL 2010 MODEL 2033
MODEL 2431 MODEL 2432 MODEL 2433MODEL 2433R
MODEL 2434
MODEL 5001
MODEL 3001B MODEL 3005A
MODEL 3321A KEW 3121A~3123A MODEL 3124 MODEL 3125 KEW 3126
KEW 5410 KEW 6010B MODEL 6011A
MODEL 5202 MODEL 8030KEW 8035 MODEL 8031
MODEL 2000MODEL 2001
KEW 2040
MODEL 6010AKEW 5010KEW 5020
MODEL 5510
KEW 1051/1052
MODEL 5406A
KEW 2003AKEW 2200
KEW 8031F KT 170/171 KT 200/203
KEW 1061/1062 KEW MATE 2012R
KEW 3128
3121A(2500V) 3122A(5000V)3123A(5000V/10000V)3321A(250V/500V/1000V)
3005A(250V/500V/1000V)3001B(500V/1000V)
3125(500/1000/2500/5000V) 3126(500/1000/2500/5000V)3124(1k~10kV Variable) 3128(500/1000/2500/5000/10000/12000V)
φ24 MAXAC/DC 300A
φ28 MAXAC 100Aφ40 MAX
AC 400A
•2433R
φ55 MAXAC/DC 2000A φ55 MAX
AC/DC 2000ARMS
φ7.5 MAXAC/DC 20Aφ33 MAX
AC 600A
MAXAC/DC 60Aφ6
φ10 MAXAC/DC 100A
φ12 MAXAC/DC 120A
RMS
φ33 MAXAC 300A φ30 MAX
AC 600A
RMS RMS
RMSRMS
DC
AC
–+
H2O
L1
L2L3
PE
BATT
N
Gas
Charger
INDUSTRIAL
APPLICATIONS
6
RCD measurement
Loop measurement
Continuty Insulation LoopRCD Earth measurementsphase rotation
Appliance Safety testing
DC current measurement
Earth electrodemeasurement by Earth clamp
High Voltageinsulation resistance &Diagnostic (PI, DD,DAR, SV)
Solar PhotovoltaicPanels
Phase rotation check(on insulated wires)
Voltage check
DC currentmeasurement
Lightingmeasurement
SolarInverter
EarthMeasurement(large installation)
Earth Leakagemeasurement
Power Quality &Energy Measurement
P44
P42
P52
P58
P36
P40
P55P23
P41
P23
P65
P67
P26
P64MODEL 5406A
MODEL 4118A
KEW 4106
KEW 3128
KEW 6016
KEW 6310
MODEL 6202
KEW 2056R
KEW 8035
KEW 2413R
KT171
KEW 4202
KEW 2056R
MODEL 5202
L
N
H2O
Gas
DC
AC
RESIDENTIAL
www.kew-ltd.co.jp 7
Lightingmeasurement
DC currentmeasurement
Solar Photovoltaicpanels
Solar Inverter
AC current measurement
Voltage measurement
Power &Energymeasurement
Insulation resistancemeasurement
Voltage and Phase Neutral check
ApplianceSafety Testing
Continuity InsulationLoop RCD Earth measurements
Earth Leakage measurements
Earth measurement
Loop measurement
P64
P13
P24
P11
P56
P32
P67
P55
P38
P52
P26
P42
MODEL 5202
KEW MATE 2012R
MODEL 2300R
MODEL 1009
KEW 6305
KT170
MODEL 3132A
MODEL 6202 KEW 6016
MODEL 2434
MODEL 4105A
MODEL 4118A
MULTIMETERS
MULTIMETERS
MU
LTIMETER
S
8
Selection Guide of Multimeters
Analogue Multimeters Digital Multimeters
1109S 1110 10181018H 1030 1009 1011
101210511052
10611062
20002001 2012R
Appearance
Detection method − − − − −
(1012) −
Maximumcount display − − 4000 4000 4000 6040 6000 50000 3400 6039
DC Basic accuracy ±3% of FS ±3% of FS 0.8% 0.8% 0.6% 0.5% 0.09% 0.02% 1.5% 1.0%
Frequencyresponse 30~20kHz 50~5kHz 50~400Hz 50~400Hz 50~400Hz 40~1kHz 40~1kHz
10~20kHz(1061)10~100kHz(1062)
50~400Hz 45~400Hz
Measurement
DC VMax 1000V 600V 600V 600V 600V 600V 1000V 1000V 600V 600V
Resolution 0.002V 0.005V 0.1mV 0.1mV 0.1mV 0.1mV 0.1mV 0.001mV 0.1mV 0.1mV
AC VMax 1000V 600V 600V 600V 600V 600V 1000V 1000V 600V 600V
Resolution 0.2V 0.2V 0.001V 0.001V 0.1mV 0.001V 0.1mV 0.01mV(1061)0.001mV(1062) 0.001V 0.001V
DCA DC A 250mA 300mA − − 10A 10A 10A 10A 60A(2000)100A(2001) 120A
ACA AC A − − − − 10A 10A 10A 10A 60A(2000)100A(2001) 120A
DC+AC DC+AC − − − − − − − − −
Resistance Ω 20MΩ 300KΩ 40MΩ 40MΩ 40MΩ 60MΩ 60MΩ 50MΩ 34MΩ 60MΩ
Continuity buzzer −
Battery test − − − − − − − − −
Diode test − − −
Capacitance − − 200µF 100µF 100µF 4000µF 1000µF 50mF − 40µF
Frequency Hz − − 10kHz 200kHz 10MHz 10MHz 99.99kHz 99.99kHz (ACA 10kHz)(ACV 300kHz)
(ACA 400Hz)(ACV 300kHz)
Duty cycle ratio DUTY − − − − −
Temperature °C − − − − (1011) − −
Decibel dB − − − − − − − −
Low power-Ω LP-Ω − − − − − − − (1062) − −
Function
Dual display − − − − − − − −
Bar graph − − − − −
Back light − − − − − − −
Data hold DATAHOLD − −
Auto hold − − − − − − − −
Peak hold PEAKHOLD − − − − − − −
(1062) − −
Max/Min/Ave Max/MinAve − − − − −
(No Ave)
(1052) − −
REL REL − − − −
Manual memory − − − − − − (1052) − −
Logging memory − − − − − − (1052) − −
Communication USB − − − − − − (1052) − −
Other
Operatingtemperature
0~40°C 0~40°C 0~40°C 0~40°C 0~40°C 0~40°C -10~55°C -20~55°C 0~40°C 0~40°C
Measurement categories
− CAT.Ⅲ 300VCAT.Ⅱ 600V CAT.Ⅲ 300V CAT.Ⅲ 600V CAT.Ⅲ 300V CAT.Ⅲ 300V
CAT.Ⅱ 600VCAT.Ⅳ 600VCAT.Ⅲ 1000V
CAT.Ⅳ 600VCAT.Ⅲ 1000V
CAT.Ⅲ 300VCAT.Ⅱ 600V
CAT.Ⅲ 300VCAT.Ⅱ 600V
Power source R6Px2,6F22x1 R6P x 2 LR-44 x 2 LR-44 x 2 R6P x 2 R6P x 2 R6P x 4 R6P x 4 R03 x 2 R03 x 2
Dimensions(L)x(W)x(D)mm
150x100x47 140x94x39 107x54x10 190x39x31 155x75x33 161x82x50 192x90x49 192x90x49 128x84x24(2000)128x92x27(2001) 128x92x27
Weight(Approx.) 330g 280g 70g 100g 260g 280g 560g 560g 210g(2000)220g(2001) 220g
Accessories
Test leads 7210A 7066A − − 7066A 7066A8216(1011) 7220A 7220A − −
Fuse 8901x2 8923x2 − − 8923x18919x1
8918x18919x1
8926x18927x1
8926x18927x1 − −
Case − 9013 9115(1018)9114(1018H) 9130 − − − − − −
MULTIMETERS
www.kew-ltd.co.jp
MU
LTIM
ETER
S
9
ANALOGUE MULTIMETERS
MODEL 1110
KEW 1109S 1109SDC V 0.1/0.5/2.5/10/50/250/1000V(20kΩ/V)
±3% of FS AC V 10/50/250/1000V(9kΩ/V)
±3% of FSDC A 50µA/2.5/25/250mA
±3% of FS
Ω 2/20kΩ/2/20MΩ ±3% of scale length
Decibel -10~+62dBhFE 0~1000(Ω × 10)
±3% of scale lengthPower source R6P(AA)(1.5V) × 2 6F22(9V) × 1Dimensions 150(L) × 100(W) × 47(D)mmWeight 330g approx.Accessories 7210A(Test leads) 8901(Fuse[0.5A/250V]) × 2
R6P(AA) × 2 6F22 × 1Instruction manual
Optional 9168(Carrying case)
1110DC V 0.3V(16.7kΩ/V) ±3% of FS
3/12/30/120/300/600V(20kΩ/V)±3% of FS
AC V 12V(9kΩ/V) ±4% of FS30/120/300/600V(9kΩ/V)±3% of FS
DC A 60µA/30/300mA±3% of FS
Ω 3/30/300kΩ±3% of scale length
Continuity buzzer Buzzer sounds below 100ΩBattery Test 1.5V(0.7~2V)
±3% of FS (10Ω load) Temperature -20°C~+150°C
±3% of scale length(0°C~+100°C)±4% of scale length(other ranges)(with the use of Temperature probe 7060)
LED 10mA approx. at 0Ω(at 3V of battery voltage)
Maximumcircuit voltage
600V AC/DC (between line/neutral)300V AC/DC (against earth)
Applicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2 CAT.Ⅱ 600V Pollution degree 2IEC 61010-031, IEC 61326-1
Power source R6P(AA)(1.5V) × 2Dimensions 140(L) × 94(W) × 39(D)mmWeight 280g approx.Accessories 7066A(Test leads) 8923(Fuse[F500mA/600V]) × 2
R6P(AA) × 2 9103(Carrying case) Instruction manualOptional 7060(Temperature probe)
AN
ALO
GU
E MU
LTIMETER
S
10
• Mirroredscaleforeasyandaccuratereading.
• OutputterminaltocutoffDCcompo-nentwhenmeasuringACvoltage.
• Safetydesignedinputterminalsandtestleads.
• HighsensitivityDC20kΩ/V.
• 1mdrop-proofheavydutydesignedtaut-bandmovement.
• Canmeasure linevoltageup toAC600V.(VoltagetogroundMAXAC300V)
(Protectedby600Vceramicfuse againstaccidentaloverload)
• Continuitybuzzer,batterycheck,LEDcheck, temperaturemeasurementfunction.
• Skeletontyperobustandclearcasewithcarryinghandle furnishedasstandardaccessory.
DCAC V
DCAC V
DC A
DC A
Ω
Ω °C
dB
1012
1011
Accessories
MODEL 7066ATest leads
MODEL 8216Temperature probe
Range:-50~300°C (-58~572°F)Note : KEW1011 can measure max. 700ºCIn order to measure over 300°C, please use a K-type temperature probe available in the market.
MAX/MIN
DIGITAL MULTIMETERS
www.kew-ltd.co.jp
KEW 1011/1012
MODEL 1009 1009DC V 400mV/4/40/400/600V(Input impedance 10MΩ)
±0.6%rdg±4dgt(400mV/4/40/400V) ±1.0%rdg±4dgt(600V)AC V 400mV/4/40/400/600V(Input impedance 10MΩ)
±1.6%rdg±4dgt(20~400mV) ±1.3%rdg±4dgt(4/40V)±1.6%rdg±4dgt(400/600V)
DC A 400/4000µA/40/400mA/4/10A±2.0%rdg±4dgt(400/4000µA) ±1.0%rdg±4dgt(40/400mA)±1.6%rdg±4dgt(4/10A)
AC A 400/4000µA/40/400mA/4/10A±2.6%rdg±4dgt(400/4000µA)±2.0%rdg±4dgt(40/400mA/4/10A)
Ω 400Ω/4/40/400kΩ/4/40MΩ±1.0%rdg±4dgt(400Ω/4/40/400kΩ/4MΩ)±2.0%rdg±4dgt(40MΩ)
Continuity buzzer 400Ω(Buzzer sounds below 70Ω)Diode test 1.5V Release Voltage : Approx. 0.4mA test currentCapacitance test 40/400nF/4/40/100µFFrequency 5.12/51.2/512Hz/5.12/51.2/512kHz/5.12/10MHzDUTY 0.1~99.9%(Pulse width/Pulse period) ±2.5%±5dgtApplicable standards IEC 61010-1 CAT.Ⅲ 300V IEC 61010-031 IEC 61326-1Power source R6P(1.5V) × 2 (Auto power off : approx. 30 minutes)
Dimensions 155(L) × 75(W) × 33(D)mmWeight 260g approx.Accessories 7066A(Test leads) 8919(Ceramic fuse[10A/600V] ) × 1
8923(Ceramic fuse [0.5A/600V] ) × 1 R6P × 2 Instruction manual
1011 1012DC V 600.0mV/6.000/60.00/600.0/600V
(Input impedance :10MΩ, 100MΩ only 600mV)±0.5%±2dgt(600.0mV/6.000/60.00/600.0V) ±0.8%±3dgt(600V)
AC V 6.000/60.00/600.0/600V(Input impedance :10MΩ)±1.0%±3dgt(6.000/60.00/600.0V)±1.5%±3dgt(600V)
6.000/60.00/600.0/600V(Input impedance :10MΩ)±1.5%±5dgt(6.000V)±1.2%±3dgt(60.00/600.0V)±1.5%±5dgt(600V)
DC A 600/6000µA/60/600mA/6/10A±1.2%±3dgt(600/6000µA/60/600mA) ±2.0%±5dgt(6/10A)
AC A 600/6000µA/60/600mA/6/10A±1.5%±4dgt(600/6000µA/60/600mA) ±2.2%±5dgt(6/10A)
Ω 600Ω/6/60/600kΩ/6/60MΩ±1.0%±2dgt(600Ω/6/60/600kΩ/6MΩ) ±2.0%±3dgt(60MΩ)
Continuity buzzer 0~600Ω(Buzzer sounds below 100Ω)Diode test 2.8V release voltage : Approx. 0.4mA test currentCapacitance test 40/400nF/4/40/400/4000µFFrequency 10/100/1000Hz/10/100/1000kHz/10MHzDUTY 0.1~99.9%(Pulse width/Pulse period) ±2.0%±2dgt(~10kHz)Temperature -50~300°C(-58~572°F)
(with the use of Temperatureprobe 8216)
—
Applicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2 CAT.Ⅱ 600V Pollution degree 2IEC 61010-031 IEC 61326
Power source R6P(1.5V) × 2 (Auto power off : approx. 15 minutes)
Dimensions 161(L) × 82(W) × 50(D)mmWeight Approx. 280gAccessories 7066A(Test leads)
8216(K-type temperature probe)(1011 Only)8918(Ceramic fuse[0.8A/600V]) × 1 built-in8919(Ceramic fuse[10A/600V]) × 1 built-inR6P × 2 Instruction manual
DIG
ITA
L M
ULT
IMET
ERS
11
• Display:4000counts.
• Autorangeandmanualrangeselec-torprovided. (with rangehold fea-ture)
• Resistance rangeprovidesaudiblecontinuitytest.
• Automatically turns power of f inabout30minutes toconservebat-terylife.
• Directcurrentmeasurementup to10AACandDC.
• WithHolster.
• 6040countswithBarGraphdisplay
• MIN/MAXfunctionenablestorecordmin&maxvalue
• REL(relativevalue)function Saving the initial value at the start of mea-
surement as a reference value (= zero) The difference between the later measured
values and the reference value is indicated on the display
• Temperaturemeasurement,select-ablefor°Cand°F(KEW1011)
supplied with K-type temperature probe (8216):
-50~300°C (-58~572°F)
• TrueRMScanmeasureandindicatedistortedwaveforms(KEW1012)
•DUTYfunction (It is possible to measure Pulse width / Pulse
period)
photo : 1012
DCAC V DC
AC A
DCAC V DC
AC A
Ω
Ω
Hz
Hz
DATAHOLD
DATAHOLD
AUTO POWEROFF
AUTO POWEROFF
REL
REL
DUTY
DUTY °C
Protection cover prevents unforeseen accident Wrapping mechanism for test lead in rear side compartment
DIGITAL MULTIMETERS
KEW 1030
KEW 1018 (Soft case type)/1018H (Hard case type)1018/1018H
DC V 400mV/4/40/400/600V(Input impedance 10MΩ)±0.8%rdg±5dgt(400mV/4/40/400V)±1.0%rdg±5dgt(600V)
AC V 4/40/400/600V(Input impedance 10MΩ)±1.3%rdg±5dgt(4/40V)±1.6%rdg±5dgt(400/600V)
Ω 400Ω/4/40/400kΩ/4/40MΩ±1.0%rdg±5dgt(400Ω/4/40/400kΩ/4MΩ)±2.5%rdg±5dgt(40MΩ)
Continuity buzzer 400Ω(Buzzer sounds below 120Ω)Diode test 4V release voltage : Approx. 0.4mA test currentCapacitance test 4nF/40nF/400nF/4µF/40µF/200µFFrequency 10/100Hz/1/10kHz (Input sensitivity Voltage:more than 1.5V)
Duty 0.1~99.9% ±2.5%rdg±5dgt(Pulse width/Pulse cycle)Applicable standards IEC 61010-1 CAT.Ⅲ 300V IEC 61010-031 IEC 61326-1Power source LR44(1.5V) × 2 (Auto power off : approx. 15 minutes)
Dimensions 107(L) × 54(W) × 10(D)mmWeight 70g approx.Accessories LR44× 2 Instruction manual
9115(Carrying case[Soft]) 9114(Carrying case[Hard])
1030DC V 400m/4/40/400/600V(5 range auto)
±0.8%rdg±5dgt(400mV~400V) ±1.0%rdg±5dgt(600V)
AC V 4/40/400/600V(4 range auto)±1.3%rdg±5dgt(4/40V)(50/60Hz) ±1.6%rdg±5dgt(400/600V) (50/60Hz)
Ω 400/4k/40k/400k/4M/40MΩ(6 range auto)±1.0%rdg±5dgt(400Ω~4MΩ) ±2.5%rdg±5dgt(40MΩ)
Continuity buzzer Buzzer sounds when resistance is 120Ω or less.Diode test Test voltage approx. 0.3~1.5VCapacitance test 50n/500n/5µ /50µ /100µF(5 range auto)
±3.5%rdg±10dgt(50nF) ±3.5%rdg±5dgt(500n~50µF)±4.5%rdg±5dgt(100µF)
Frequency 5/50/500/5k/50k/200kHz ±0.1%rdg±5dgt(Input sensitivity Voltage : more than 1.5V[~50kHz] Voltage:more than 10V[>200kHz])
Duty 0.1~99.9% ±2.5%rdg±5dgt (Pulse width / Pulse cycle)Data hold The measured value can be hold by pressing Data hold buttonBattery voltage warning When the battery voltage drops to 2.4V±0.2V or lessApplicable standards IEC 61010-1 CAT.Ⅲ 600V
IEC 61010-031 IEC 61326-1(EMC)Power source Button type battery LR44(SR44)(1.5V) × 2
(Auto power off : approx. 30 minutes)
Dimensions 190(L) × 39(W) × 31(D)mmWeight Approx. 100g (including batteries)Accessories 9130(Carrying case) LR44(1.5V) × 2 Instruction manual
DIG
ITAL M
ULTIM
ETERS
• Display:4000counts.
• Autorange.
• Diodetestfeature.
• Capacitancetestfeature.
• Continuitytest.
• Compact inSize, Light inWeight andSimpleinUse
• Doublemouldingprovidescomfortableandgoodfeelinginhand
• Penlightilluminatesbrightlythepointtobemeasured,evenindarkplace
• BacklightLCD ishighlyvisible,even indarkness
• Uniquewrappingmechanismfortestleadintherearsidecompartment
• Uniqueprotectionmechanismforthetestprodforsafety
• AllrangesincludingOhmrangearepro-tectedagainstoverloadvoltageof600V
12
Soft case type Hard case type
Release test lead from holder.Close the lid after taking out the test lead through upper right hand side hole.
Pull up and turn.then, cover
DCAC V
DCAC V
Ω
Ω
Hz
Hz
DATAHOLD
DATAHOLD
AUTO POWEROFF
AUTO POWEROFF
REL
REL
DUTY
DUTY
KEW MATE
DIGITAL MULTIMETERS
www.kew-ltd.co.jp
KEWMATE 2012R
/2001MODEL 2000 2000 2001DC V 340mV/3.4/34/340/600V (Input impedance : 10MΩ)
±1.5%rdg±4dgtAC V 3.4/34/340/600V (Input impedance : 10MΩ)
±1.5%rdg±5dgt[50~400Hz]DC A 60A ±2%rdg±5dgt 100A ±2%rdg±5dgtAC A 60A ±2%rdg±5dgt(50/60Hz) 100A ±2%rdg±5dgt(50/60Hz)
Ω 340Ω/3.4/34/340kΩ/3.4/34MΩ±1%rdg±3dgt(0~340kΩ)±5%rdg±5dgt(3.4MΩ)±15%rdg±5dgt (34MΩ)
Continuity buzzer Buzzer sounds below 30±10Ω(Continuity buzzer works on 340Ω range only)
Frequency (AC A)3.4/10kHz ±0.1%rdg±1dgt(AC V)3.4/34/300kHz ±0.1%rdg±1dgt(Input sensitivityCurrent:more than 15AVoltage:more than 30V)
(Input sensitivityCurrent:more than 25AVoltage:more than 30V)
Conductor size φ6mm max. φ10mm max.Applicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1Power source R03(DC1.5V) x 2
*Continuous measuring time : approx. 45 hours (Auto power save : approx. 10 minutes)
Dimensions 128(L) × 87(W) × 24(D)mm 128(L) × 92(W) × 27(D)mmWeight 210g approx. 220g approx.Accessories R03(1.5V) × 2
Instruction manualOptional 9107(Carrying case[Soft])
2012RDC V 600.0mV/6.000/60.00/600.0V
(Input impedance: approx. 10MΩ) ±1.0%rdg±3dgtAC V 6.000/60.00/600.0V (Input impedance: approx.10MΩ)
±1.5%rdg±5dgt (45~400Hz)DC A 60.00/120.0A ±2.0%rdg±8dgt (60A)
±2.0%rdg±5dgt (120A)AC A 60.00/120.0A ±2.0%rdg±5dgt (45~65Hz)
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ±1.0%rdg±5dgt (600Ω/6/60/600kΩ)±2.0%rdg±5dgt (6MΩ) ±3.0%rdg±5dgt (60MΩ)
Continuity buzzer Buzzer sounds below 35±25ΩDiode test 2V ±3.0%rdg±5dgt Open-loop voltage: approx. 2.7VCapacitance 400.0nF/4.000/40.00µF ±2.5%rdg±10dgtFrequency AC A: 100/400Hz
±0.2%rdg±2dgt (100Hz) ±0.1%rdg±1dgt (100~400Hz)AC V: 100/1000Hz/10/100/300.0kHz ±0.2%rdg±2dgt (100Hz) ±0.1%rdg±1dgt (1000Hz/10/100/300.0kHz)(Input sensitivity Current: more than 6A Voltage: more than 6V [~10kHz]/more than 20V [10k~300kHz])
Conductor size φ12mm max.Applicable Standards IEC 61010-1 CAT.Ⅲ 300V, CAT.Ⅱ 600V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326Power source R03 (1.5V) × 2
*Continuous measuring time:DCV: approx. 150hours, ACA: approx. 25hours(Auto power save: approx. 15 minutes)
Dimensions 128 (L) × 92 (W) × 27 (D) mmWeight 220g approx. (including batteries)Accessories R03 (1.5V) × 2, Instruction manualOptional 9107 (Carrying case [Soft])
DIG
ITA
L M
ULT
IMET
ERS
• CapableofmeasuringACandDCcurrentsupto60A(MODEL2000)/100A(MODEL2001)withOPENCLAMPSENSOR.
• 3400countswithbargraphdisplay.
• Pocketsizeandheavydutydesign.
• Sleepfunctiontosavebatteryconsumption.
• DesignedtointernationalsafetystandardIEC61010-1CAT.Ⅲ300V
• InnovativeMulthimeterswithcurrentmeasurementsupto120AAC/DC
• UniqueOpenJawtechnologyforAC/DCcurrentmeasurements
• Verycompactandasreliableasatraditionalfullsizemultimeter
13
Measuring current in a Switchboard Servicing a Forklift Servicing a car
photo : 2001
DCAC ADC
AC V Ω Hz DATAHOLD
AUTO POWERSAVE
DCAC V DC
AC AØ12 Ω HzMAX120A
DATAHOLD
AUTO POWERSAVE
Ø6 Ø10MAX60A
MAX100A
1061,1062 1062
1062 Except for 1051
Except for 1051
1061,1062 1061,1062
DIGITAL MULTIMETERS
KEW 1051/1052KEW 1061/1062
1051 1052 1061 1062Detection mode RMS MEAN/RMS (switch) RMS MEAN/RMS (switch)DC V 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V]) ±0.09%rdg±2dgt (Basic accuracy)
50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V (Input impedance: Approx. 100MΩ [50/500/2400mV], 10MΩ [5/50/500/1000V]) ±0.02%rdg±2dgt (Basic accuracy)
AC V[RMS]
600.0mV/6.000/60.00/600.0/1000V(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V], 10MΩ<50pF [60/600/1000V]) ±0.5%rdg±5dgt (Basic accuracy)
50.000/500.00mV/5.0000/50.000/500.00/1000.0V(Input impedance: 11MΩ<50pF [50/500mV/5V],10MΩ<50pF [50/500/1000V])±0.7%rdg±30dgt (Basic accuracy) ±0.4%rdg±30dgt (Basic accuracy)
AC V[MEAN] *
− − −
50.000/500.00mV/5.0000/50.000/500.00/1000.0V(Input impedance: 11MΩ<50pF [50/500mV/5V], 10MΩ<50pF[50/500/1000V])±1%rdg±30dgt (Basic accuracy)
DCV+ACV− −
5.0000/50.000/500.00/1000.0V(Input impedance: 11MΩ<50pF [5V], 10MΩ<50pF [50/500/1000V])±1%rdg±10dgt (Basic accuracy) ±0.5%rdg±10dgt (Basic accuracy)
DC A 600.0/6000µA/60.00/440.0mA/6.000/10.00A ±0.2%rdg±2dgt (Basic accuracy) 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A ±0.2%rdg±5dgt (Basic accuracy)
AC A[RMS] 600.0/6000µA/60.00/440.0mA/6.000/10.00A ±0.75%rdg±5dgt (Basic accuracy)
500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A±1%rdg±20dgt (Basic accuracy) ±0.75%rdg±20dgt (Basic accuracy)
AC A[MEAN] * − − −
500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A ±1.5%rdg±20dgt (Basic accuracy)
DCA+ACA− −
500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A±1.5%rdg±10dgt (Basic accuracy) ±1%rdg±10dgt (Basic accuracy)
Ω600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ ±0.4%rdg±1dgt (Basic accuracy)
500.00Ω/5.0000/50.000/500.00kΩ/5.0000/50.000MΩ±0.1%rdg±2dgt (Basic accuracy) ±0.05%rdg±2dgt (Basic accuracy)
LowPower-Ω *− − −
5.000/50.00/500.0kΩ/5.000MΩ±0.2%rdg±3dgt (Basic accuracy)
Continuity buzzer 600.0Ω (The buzzer turns on for resistances lower than 50±30Ω) 500.0Ω (The buzzer turns on for resistances lower than 100±50Ω)Diode test 2.000V ±1%rdg±2dgt Open circuit voltage:
<3.5V (Approx. 0.5mA Measuring Current)2.4000V ±1%rdg±2dgt Open circuit voltage: <5V (Approx. 0.5mA Measuring Current)
Capacitance 10.00/100.0nF/1.000/10.00/100.0/1000µF ±2%rdg±5dgt (Basic accuracy) 5.000/50.00/500.0nF/5.000/50.00/500.0µF/5.000/50.00mF ±1%rdg±5dgt (Basic accuracy) Frequency 10.00~99.99/90.0~999.9Hz/0.900~9.999/9.00~99.99kHz
±0.02%rdg±1dgt (Basic accuracy)
2.000~9.999/9.00~99.99/90.0~999.9Hz/0.900~9.999/9.00~99.99kHz±0.02% rdg±1dgt (Basic accuracy)
DUTY − − 10~90% ±1%rdgTemperature -50~600ºC ±2%rdg±2ºC (with the use of K-type Temperature probe) -200~1372ºC ±1%rdg±1.5ºC (with the use of K-type Temperature probe)Application standards IEC 61010-1 CAT.Ⅳ 600V, CAT.Ⅲ 1000V Pollution degree 2, IEC 61010-031, IEC 61326-1 (EMC)Power source R6 (1.5V)×4 (Auto power off: approx. 20 minutes)
Dimensions 192(L)×90(W)×49(D) mmWeight Approx. 560g (including batteries)Accessories 7220A (Test Leads), R6×4, 8926 (Fuse [440mA/1000V])×1 (included), 8927 (Fuse [10A/1000V])×1 (included) Instruction manual
DIG
ITAL M
ULTIM
ETERS
High Accuracy, High Performance and Reliable Measurements •Topaccuracy0.02%basicDCaccuracyfor1061/1062.0.09%basicDCaccuracyfor1051/1052.
•Dualdisplay1061/1062:50,000counts,Bargraphwith51segments.Whitebacklightdisplay.1051/1052:6,000counts,Bargraphwith31segments.Orangebacklightdisplay.
• True-RMSMeasurements
• WideACFrequencybandwidthfrom10Hzto100kHz*onlyfor1062
• True-RMSorMEANvaluedetectionmodecanbeselected*onlyfor1052,1062
• DC+ACTRMSMeasurement*onlyfor1061,1062 ACandDCvaluesaredisplayedsimultaneouslyviadualdisplay.
• FastPeakHoldresponsetimeof250µs*onlyfor1062
• Low-passfilter*exceptfor1061
• LowPower-Ωmeasurements*onlyfor1062
• Usercalibrationfunction
Safety design for industrial use•ComplieswithIEC61010-1CAT.Ⅲ1000V,CAT. Ⅳ600V
•Terminalshuttertopreventincorrecttestleads’insertionincurrentterminals
•VerywideoperatingtemperaturerangeFrom-20to+55°Cfor1061/1062From-10to+55°Cfor1051/1052
Reliable support for data management
*except for 1051• Largedatainternalmemory
• DownloaddataandLiveMonitoringonaPCviatheUSBinterface (OptionforUSBCommunicationset)*onlyfor1062
14
photo : 1062photo : 1052
Hz
CAT.Ⅳ600V
DUTY
DC+AC LP-ΩDCAC V DC
AC A ΩDATAHOLD
PEAKHOLD
MAX/MINAVG
AUTO POWEROFF
REL Filter
USB
°C dB
Alligator clip (7234)
Carrying case (9154) Banana f4mm adjuster plug (7146)
USB Communication set (8241)
DIGITAL MULTIMETERS
www.kew-ltd.co.jp
DIG
ITA
L M
ULT
IMET
ERS
15
Large internal memory to store test data• KEW1062:10,000datainLoggingmode,100datamanuallysaved.• KEW1061:1,000datainLoggingmode,100datamanuallysaved.• KEW1052:1,600datainLoggingmode,100datamanuallysaved.• Loggingintervalcansetfrom1sec.to30min.
Test data can be transferred to a PC or directly to a Printer*• Real-timedatacanbetransferredandshownonaPC.• Real-timetransferringpermitsthesavingofaconsiderableamountofdataonaPC.• StoreddataofinternalmemorycanbemonitoredbyPC.
Data management with the software DMM Application*• StoreddataofinternalmemorycanbemonitoredbyPC.• ListofmeasureddatacanbeconvertedintoGraph.• DatacanbetransferredtoExcel**andsavedasCSVfile.
*Optional accessories are required, refer to last page.**Excel is a registered trademark of Microsoft in the USA.
Data analysis with Excel
DMM Application software
Printed items (from the left)
・L: Logging memory ・4 digit numbers: Data number ・N: Normal measurement (O: at "OL" display) (B: at "Battery warning" display) ・5 digit numbers: Measurement ・VDC: Unit (VDC is DC Voltage)
Printer output
L0000 N,+12.539 VDCL0001 N,+12.532 VDCL0002 N,+12.532 VDCL0003 N,+12.529 VDCL0004 N,+12.532 VDCL0005 N,+12.538 VDCL0006 N,+12.541 VDCL0007 N,+12.546 VDCL0008 N,+12.552 VDCL0009 N,+12.557 VDCL0010 N,+12.555 VDCL0011 N,+12.554 VDCL0012 N,+12.553 VDCL0013 N,+12.553 VDC
Reliable support for data management※ except for 1051
Clamp sensor Specification
Thermocouple Type K Specification
Optional AccessoriesDescription MODEL Contents
Alligator Clip 7234 CAT.Ⅳ 600V、CAT.Ⅲ 1000V 1set USB Communication set 8241 USB adaptor+USB cable+DMM SoftwareDMM Printer full set 8249 8243+8246+8248
Printer Communication set 8243 Printer Adapter+RS232 cablePrinter 8246 Printer (paper width 112mm)+paper×1 rollAC adapter for printer [EU] 8248 AC230V±10%
Thermal paper for printer 8247 10 rolls
Thermocouple Type K
8405 Max. 500ºC (Surface type, Point material: Ceramic) 8406 Max. 500ºC (Surface type) 8407 Max. 700ºC (Liquid, Semi-solid) 8408 Max. 600ºC (Air, Gas)
Clamp sensor
8121 AC 100A8122 AC 500A8123 AC 1000A8146 AC 30A8147 AC 70A8148 AC 100A
Banana φ4mm Adjuster Plug 7146 length :190mmCarrying case 9154 Soft case(for the main unit with test leads and communication cable)
<DMM Printer full set (8249)>
AC/DC current sensor AC current sensor Leakage & AC current sensor
8115 8121 8122 8123 8146 8147 8148
Conductor size f12 f24 f40 f55 f24 f40 f68Rated current Surface type AC 100A AC 500A AC 1000A AC 30A AC 70A AC 100AOutput voltage (Liquid, Semi-solid) AC 500mV/100A AC 500mV/500A AC 500mV/1000A AC 1500mV/30A AC 3500mV/70A AC 5000mV/100A
Accuracy(50/60Hz)
AC ±1.0%rdg±0.4mVDC ±1.0%rdg±0.4mV(This accuracy is defined after a zero-adjustment)
±2.0%rdg±0.3mV0~15A ±1.0%rdg±0.1mV15~30A ±5.0%rdg
0~40A ±1.0%rdg±0.1mV40~70A ±5.0%rdg
0~80A ±1.0%rdg±0.1mV80~100A ±5.0%rdg
Frequency range 40Hz~1kHzDimensions 127(L)×42(W)×22(D)mm 97(L)×59(W)×26(D)mm 128(L)×81(W)×36(D)mm 170(L)×105(W)×48(D)mm 100(L)×60(W)×26(D)mm 128(L)×81(W)×36(D)mm 186(L)×129(W)×53(D)mmWeight approx. 160g approx. 150g approx. 260g approx. 360g approx. 150g approx. 240g approx. 510g
MODEL UsageMeasurement temperature
Tolerance (t: measurement temperature)
Response speed
8405(Surface type, Point material: Ceramic) Max. 500ºC
±2.5ºC/t=-40ºC~333ºC, ±0.0075×|t|ºC/t=333ºC~500ºC
approx. 1.8 Sec.
8406 Surface type approx. 1.0 Sec.
8407 (Liquid, Semi-solid) Max. 700ºC±2.5ºC/t=-40ºC~333ºC, ±0.0075×|t|ºC/t=333ºC~700ºC
1 Sec. or less
8408 (Air, Gas) Max. 600ºC±2.5ºC/t=-40ºC~333ºC, ±0.0075×|t|ºC/t=333ºC~600ºC
0.4 Sec.
MODEL 8406
MODEL 8408
MODEL 8405
MODEL 8407
8243
82468248
System requirements
OS: Windows®7(32/64bit)/Vista/XPDisplay: XGA (Resolution 1024 x 768 dots) or moreHard-disk: Space required 10Mbyte or moreOthers: With CD-ROM drive and USB port
* Windows® is a registered trademark of Microsoft in the United States.
CLAMP METERS
CLAMP METERS
CLA
MP
METER
S
16
Selection Guide of Clamp Meters
AC Clamp Meters Fork Current Tester
DC Milliamp Clamp Meter
2608A 2805 2007A 2017 2031 2027 2040 2200 2002PA 2002R 2300R 2500
Appearance
Conductor Фsizef33mm f30mm f33mm f33mm f24mm f33mm f33mm f33mm f55mm f55mm f10mm f6 mm
Display Analogue Analogue Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital
Detection method − − − − − − − − −
Frequencyresponse 50/60Hz 50~400Hz 40~400Hz 45~1kHz 40~1kHz 40~1kHz 40~400Hz
45~65Hz(ACA)45~500Hz(ACV)
40~1kHz 40~1kHzDC
50/60HzDC
Measurement
AC AMax 300A 600A 600A 600A 200A 600A 600A 1000A 2000A 2000A 100A −
Resolution 0.2A 0.2A 0.1A 0.1A 0.01A 0.1A 0.1A 0.01A 0.1A 0.1A 0.1A −
Accracy ±3% of FS ±3% of FS ±1.5%R±4D ±1.5%R±4D ±2%R±5D ±1.5%R±4D ±1.5%R±5D ±1.4%R±6D ±1%R±3D ±1.5%R±3D ±2%R±5D −
DC AMax − − − − − − − − − − 100A 120mA
Resolution − − − − − − − − − − 0.1A 0.01mA
Accracy − − − − − − − − − − ±2%R±5D ±0.2%R±5D
AC Voltage AC V 600V 600V 750V 600V − 600V 600V 600V 750V 750V − −
DC Voltage DC V 60V − − − − − 600V 600V 1000V 1000V − −
Resistance Ω 10KΩ 20KΩ 4000Ω 200Ω − 200Ω 60MΩ 40MΩ 400KΩ 400KΩ − −
Continuity buzzer − − − − −
Frequency Hz − − − − − − 10kHz − − − − −
Duty cycle ratio DUTY − − − − − − − − − − −
Diode test − − − − − − − − − − −
Capacitance − − − − − − − − − − − −
Temperature °C − − − − − − − − − − −
Function
Non contactvoltage NCV − − − − − − − − − −
Back light − − − − − − − − − − −
Data hold DATAHOLD
Peak hold PEAKHOLD − − − − − − − − − −
Max/Min MAX/MIN − − − − − − − − − − −
Relative REL − − − − − − − − − − −
Output OUT PUT − − − − − − − − −
Other
Operatingtemperature
0~40°C -10~50°C 0~40°C -10~50°C 0~40°C -10~50°C 0~40°C 0~40°C 0~40°C 0~40°C 0~40°C -10~50°C
Measurementcategories
CAT.Ⅲ 300VCAT.Ⅱ 600V −
CAT.Ⅲ 300VCAT.Ⅱ 600VCAT.Ⅰ 1000V
CAT.Ⅲ 600V CAT.Ⅲ 300V CAT.Ⅲ 600V CAT.Ⅳ 600VCAT.Ⅲ600V(ACA)
CAT.Ⅲ300V(AC/DCV)CAT.Ⅱ600V(AC/DCV)
CAT.Ⅲ 600VCAT.Ⅱ 1000V
CAT.Ⅲ 600VCAT.Ⅱ 1000V CAT.Ⅲ 300V CAT.Ⅱ 300V
Power source R6P x 1 R6P x 1 R03 x 2 6F22 x 1 LR-44 x 2 6F22 x 1 R03 x 2 R03/LR03 x 2 R6P x 2 R6P x 2 R03 x 2 LR6 x 4
Dimensions(L)x(W)x(D)mm
193x78x39 220x83x40 195x78x36 208x91x40 147x58.5x26 208x91x40 243x77x36 190x68x20 247x105x49 247x105x49 161x40x30
111x61x40(Display unit)104x34x20
(Sensor)
Weight(Approx.) 275g 390g 260g 400g 100g 400g 300g 120g 470g 470g 110g 290g
Accessories
Test leads 7066A 7067 7066A 7066A − 7066A 7066A 7107A 7107A 7107A − −
Fuse 8923x2 8901x2 − − − − − − − − − −
Case 9097 9144 9097 9079 9090 9079 9094 9160 9094 9094 9113 9096
CLAMP METERS
www.kew-ltd.co.jp
CLA
MP
MET
ERS
17
Selection Guide of Clamp Meters
AC/DC Clamp Meters Leakage Clamp Meters
2010 2033 2046R 20552056R 2003A 2009R 2431 2432 2433
2433R 2412 2434 2413F2413R
Appearance
Conductor Фsizef7.5mm f24mm f33mm f40mm f55mm f55mm f24mm f40mm f40mm f40mm f28mm f68mm
Detection method − −
(2056R) − − − (2433R) − −
(2413R)Frequencyresponse
DC40~2kHz
DC20~1kHz
DC40~400Hz
DC40~400Hz
DC40~1kHz
DC20~1kHz
40~400Hz 20~1kHz 20~1kHz 40~400Hz 40~400Hz 40~1kHz
Measurement
AC A
Max 20A 300A 600A 1000A 2000A 2000A 200A 100A 400A 500A 100A 1000A
Resolution 0.1mA 0.01A 0.1A 0.1A 0.1A 0.1A 0.01mA 0.001mA 0.01mA 0.01mA 0.1mA 0.1mA
Accracy ±1%R±2D ±1%R±4D ±2%R±5D ±2%R±5D ±1.5%R±2D ±1.3%R±3D ±2%R±4D ±1%R±5D ±1%R±5D ±1%R±3D ±2%R±4D±1%R±2D(2413R)
±1.8%R±5D(2413F)
DC AMax 20A 300A 600A 1000A 2000A 2000A
− − − − − −Resolution 0.001A 0.01A 0.1A 0.1A 0.1A 0.1A
Accracy ±1%R±2D ±1%R±4D ±1.5%R±5D ±1.5%R±5D ±1.5%R±2D ±1.3%R±2D
AC Voltage AC V − − 600V 600V 750V 750V − − − 600V − −
DC Voltage DC V − − 600V 600V 1000V 1000V − − − − − −
Resistance Ω − − 60MΩ 60MΩ 4000Ω 4000Ω − − − 200Ω − −
Continuity buzzer − − − − − − − −
Frequency Hz − − 10kHz 10kHz − 10kHz − − − − − −
Duty cycle ratio DUTY − − − − − − − − − −
Diode test − − − − − − − − − −
Capacitance − − − − − − − − − −
Temperature °C − − (2056R) − − − − − − − −
Function
Non contactvoltage NCV − − − − − − − − − −
Back light − − − − − − − − − (2413R)
Data hold DATAHOLD −
Peak hold PEAKHOLD − −
(2056R)
(Max) * − − −
Max/Min MAX/MIN − − − − − − − − − −
Relative REL − − − − − − − − − −
Output OUT PUT − − − − − − −
Filter Filter − − − − − −
Other
Operatingtemperature
0~50°C 0~40°C 0~40°C 0~40°C 0~40°C 0~40°C 0~40°C 0~40°C 0~40°C 0~40°C 0~40°C 0~40°C
MeasurementCategories
− CAT.Ⅲ 300V CAT.Ⅳ 600V CAT.Ⅳ 600VCAT.Ⅳ 600VCAT.Ⅲ 1000V
CAT.Ⅳ 600VCAT.Ⅲ 1000V
CAT.Ⅲ 300V CAT.Ⅲ 300V CAT.Ⅲ 300V − CAT.Ⅲ 300V CAT.Ⅲ 300V
Power source 6LR61 x 1 LR-44 x 2 R03 x 2 R03 x 2 R6P x 2 R6P x 2 LR-44 x 2 R03 x 2 R03 x 2 6F22 x 1 R03 x 2 6F22 x 1
Dimensions(L)x(W)x(D)mm
142x64x26(Display unit)153x23x18
(Sensor)
147x59x25 243x77x36 254x82x36 250x105x49 250x105x49 149x60x26 185x81x32 185x81x32 209x96x45 169x75x40 250x130x50
Weight(Approx.) 220g 100g 300g 310g 530g 540g 120g 290g 270g 450g 220g 570g
AccessoriesTest leads − − 7066A 7066A 7107A 7107A − − − 7066A − −
Case 9071 9090 9094 9094 9094 9094 9090 9097 9097 9072 9097 9094
* In the PEAK mode, the auto-ranging feature is disabled and measuring ranges are fixed as follows. DC/ ACA :0-400.0A DC/ ACV :0-400.0V
CLAMP METERS
CLA
MP
METER
S
18
ANALOGUE/DIGITAL CLAMP METERS
www.kew-ltd.co.jp
MODEL 2805
MODEL 2007A
MODEL 2608A 2608AAC A 6/15/60/150/300A ±3% of FSAC V 150/300/600V ±3% of FSDC V 60V ±3% of FS
Ω 1/10kΩ(25/250Ω mid-scale)±2% of scale length
Temperature -20°C~+150°C(with the use of Temperature probe 7060)±5°C(0°C~+100°C) ±10°C(other ranges)
Conductor size φ33mm max.Frequency response 50/60HzApplicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2
IEC 61010-031 IEC 61010-2-032Power source R6P(AA)(1.5V) × 1Dimensions 193(L) × 78(W) × 39(D)mmWeight 275g approx. Accessories 7066A(Test leads) 8923(Fuse [0.5A/600V]) × 2
9097(Carrying case) R6P(AA) × 1Instruction manual
Optional 7060(Temperature probe)8008(Multi-tran)
2805AC A 6/20/60/200/600A ±3% of FSAC V 150/300/600V ±3% of FS
Ω 2kΩ(25Ω mid-scale)±3% of scale length
Conductor size φ30mm max.Frequency response 50/400HzPower source R6P(AA)(1.5V) × 1Dimensions 220(L) × 83(W) × 40(D)mm Weight 390g approx.Accessories 7067(Test leads) 8901(Fuse [0.5A/250V]) × 2
9144(Carrying case) R6P(AA) × 1Instruction manual
Optional 8008(Multi-tran)
2007AAC A 400/600A
±1.5%rdg±4dgt[50/60Hz] ±2%rdg±5dgt[40~400Hz]AC V 400/750V
±1.2%rdg±3dgt[50/60Hz] ±1.5%rdg±4dgt[40~400Hz]
Ω 400/4000Ω±1.5%rdg±2dgt
Continuity buzzer buzzer sounds below 50±35ΩConductor size φ33mm max.Frequency response 40Hz~400HzApplicable standards IEC 61010-1 CAT.Ⅲ 300V, CAT.Ⅱ 600V, CAT.Ⅰ 1000V
IEC 61010-031 IEC 61010-2-032 IEC 61326(EMC)Power source R03(AAA)(1.5V) × 2
*Continuous measuring time : approx. 200 hours (Auto sleep function : approx. 10 minutes)
Dimensions 195(L) × 78(W) × 36(D)mmWeight 260g approx.Accessories 7066A(Test leads) 9097(Carrying case)
R03(1.5V) × 2 Instruction manualOptional 8008(Multi-tran)
AN
ALO
GU
E/D
IGIT
AL
CLA
MP
MET
ERS
• DCvoltage range is also availableespecially forcheckingemergencybatteryoperatedpowersupply.
• Canmeasuretemperatureusingop-tionalprobe.
• Teardropshaped transformer jawsforeaseofuse.
• Rangeswitchselectsonlyonerotaryscaleatatime,makingiteasytotakereadingscorrectly.
• Alongtimesellerwithprovenreputa-tionworldwide for itseasy-to-usefunctions.
• Sleepfunctiontosavebattery.
• Dataholdfunction.
• Digitaldisplaywithmaximum4000counts.
19
AC A
AC A
AC A
AC V
AC V
Ω
Ω
°CØ33
Ø30
Ø33
DATAHOLD
DATAHOLD
MAX 300A
MAX 600A
MAX 600A
DCAC V
Ω
2002R
10ms
DIGITAL CLAMP METERS AC
MODEL 2017
MODEL 2027
MODEL 2002PA/2002R 2002PA 2002RAC A 400A(0~400A)
±1%rdg±3dgt[50/60Hz]±2%rdg±3dgt[40Hz~1kHz]2000A(0~1500A) ±1%rdg±3dgt[50/60Hz]±3%rdg±3dgt[40Hz~1kHz]2000A(1500~2000A) ±3.0%rdg[50/60Hz]
400A(0~400A)±1.5%rdg±3dgt[45~65Hz]±2.5%rdg±3dgt[40Hz~1kHz]2000A(0~1500A) ±2%rdg±5dgt[45~65Hz]±3%rdg±5dgt[40Hz~1kHz]2000A(1501~2000A) ±4%rdg[50/60Hz]
AC V 40/400/750V ±1%rdg±2dgt[50/60Hz]±1.5%rdg±3dgt[40Hz~1kHz]
40/400/750V ±1%rdg±2dgt[45~65Hz]±1.5%rdg±3dgt[40Hz~1kHz]
DC V 40/400/1000V ±1%rdg±2dgtContinuity buzzer buzzer sounds below 50±35ΩΩ 400Ω/4k/40k/400kΩ ±1.5%rdg±2dgtConductor size φ55mm max.Frequency response 40Hz~1kHzOutput Recorder:DC400mV against AC400A DC200mV against AC2000AApplicable standards IEC 61010-1 CAT.Ⅲ 600V CAT.Ⅱ 1000V
IEC 61010-031 IEC 61010-2-032 IEC 61326-1Power source R6P(AA)(1.5V) × 2 *Continuous measuring time : approx. 150 hours (2002PA)
*Continuous measuring time : approx. 80 hours (2002R) (Auto power save : approx. 10 minutes)
Dimensions 247(L) × 105(W) × 49(D)mmWeight 470g approx.Accessories 7107A(Test leads) 8201(Output plug) 9094(Carrying case)
R6P(AA) × 2 Instruction manualOptional 8008(Multi-tran) 7014(Output cord)
2017AC A 200/600A
±1.5%rdg±4dgt[50/60Hz](200A)±1%rdg±3dgt[50/60Hz](600A)±2%rdg±5dgt[45Hz~1kHz]
AC V 200/600V±1%rdg±2dgt[50/60Hz] ±1.5%rdg±4dgt[45Hz~1kHz]
Ω 200Ω ±1.2%rdg±2dgt
Continuity buzzer buzzer sounds below 30±20ΩConductor size φ33mm max.Frequency response 45Hz~1kHzApplicable standards IEC 61010-1 CAT.Ⅲ 600V Pollution degree 2
IEC 61010-031Power source 6F22(9V) × 1 *Continuous measuring time : approx. 200 hours
Dimensions 208(L) × 91(W) × 40(D)mm Weight 400g approx.Accessories 7066A(Test leads) 9079(Carrying case)
6F22 × 1 Instruction manualOptional 8008(Multi-tran)
2027AC A 200/600A(True RMS)
±1.5%rdg±4dgt[50/60Hz] (CF<3)±2%rdg±5dgt[40Hz~1kHz](Sine wave)
AC V 200/600V(True RMS) (CF<3)±1.5%rdg±4dgt[50/60Hz] ±2%rdg±5dgt[40Hz~1kHz]
Ω 200Ω ±1.2%rdg±4dgt
Continuity buzzer buzzer sounds below 30±20ΩConductor size φ33mm max.Frequency response 40Hz~1kHzApplicable standards IEC 61010-1 CAT.Ⅲ 600V Pollution degree 2
IEC 61010-031Power source 6F22(9V) × 1 *Continuous measuring time : approx. 200 hours)
Dimensions 208(L) × 91(W) × 40(D)mmWeight 400g approx.Accessories 7066A(Test leads) 9079(Carrying case)
6F22 × 1 Instruction manualOptional 8008(Multi-tran)
DIG
ITAL C
LAM
P M
ETERS A
C
• CanmeasurelargeACcurrent upto2000A.
• Peakholdfunction.
• 55mm-dialargeteardropshaped jaws.
• Teardropshaped jaws foreaseofuseintightplacesandcrowdedcableareas.
• Threefunctionsinoneunit;ACcur-rent,ACvoltageandresistance.
• Resistance rangeprovidesaudiblecontinuitytest.
• Frequency response f rom 40Hzto1kHzonACcurrentandvoltageranges.
• TrueRMS reading instrument thatpermitsprecisemeasurementsofnon-sinusoidalwaveformACcurrentandvoltage.
• Threefunctionsinoneunit;ACcur-rent,ACvoltageandresistance.
photo : 2002R
20
AC A DCAC V Ω
DATAHOLD
PEAKHOLD
OUTPUT
MAX 2000A
AUTO POWERSAVE
AC A AC VØ33
Ø55
Ø33
MAX 600A
DATAHOLD
DATAHOLD
AC A AC V ΩMAX 600A
Ω
DIGITAL CLAMP METERS AC
www.kew-ltd.co.jp
KEW 2200
KEW 2040
MODEL 2031
2200AC A 40.00/400.0/1000A (Auto-ranging)
±1.4%rdg±6dgt(50/60Hz)±1.6%rdg±6dgt(45~65Hz)
AC V 4.000/40.00/400.0/600V (Auto-ranging) ±1.8%rdg±7dgt(45~65Hz) ±2.3%rdg±8dgt(65~500Hz)
DC V 400.0mV/4.000/40.00/400.0/600V (Auto-ranging) ±1.0%rdg±3dgt
Ω 400.0Ω/4.000/40.00/400.0kΩ/4.000/40.00MΩ (Auto-ranging) ±2.0%rdg±4dgt(0~400kΩ) ±4.0%rdg±4dgt(4MΩ) ±8.0%rdg±4dgt(40MΩ)
Continuity buzzer buzzer sounds below 50±30ΩConductor size φ33mm max.Applicable standards IEC 61010-1 CAT.Ⅲ 600V (AC A),
CAT.Ⅲ 300V/CAT.Ⅱ 600V(AC/DC V), Pollution degree 2IEC 61010-031, IEC 61010-2-032IEC 61326(EMC)
Power source R03/LR03(AAA)(1.5V) × 2Dimensions 190(L) × 68(W) × 20(D)mmWeight Approx. 120g(including batteries)Accessories 7107A(Test leads), 9160(Carrying case),
R03(AAA)× 2, Instruction manualOptional 8008(Multi-tran)
2031AC A 20A
±2%rdg±5dgt[50Hz~1kHz]200A ±2%rdg±5dgt[50/60Hz]±3%rdg±10dgt[40Hz~1kHz]
Conductor size φ24mm max.Frequency response 40Hz~1kHzApplicable standards IEC 61010-1 CAT.Ⅲ 300VPower source LR-44(1.5V) × 2
*Continuous measuring time : approx. 100 hours (Auto power off : approx. 10 minutes)
Dimensions 147(L) × 58.5(W) × 26(D)mm Weight 100g approx.Accessories 9090 (Carrying case)
LR-44 × 2Instruction manual
Optional 8008(Multi-tran)
2040AC A 0~600.0A
±1.5%rdg±5dgt(50/60Hz) ±3.5%rdg±8dgt(40~400Hz)AC V 6/60/600V (Auto Ranging)
±1.3%rdg±4dgt(50/60Hz) ±3.0%rdg±5dgt(40~400Hz)DC V 600m/6/60/600V (Auto Ranging) ±1.0%rdg±3dgt
Ω 600/6k/60k/600k/6M/60MΩ (Auto Ranging)±1%rdg±5dgt(600~6M) / ±5%rdg±8dgt(60M)
Continuity buzzer Buzzer Sounds at 100ΩHz 10/100/1k/10kHz(Auto Ranging)
(Input sensitivity Current:more than 50A[~1kHz] Voltage:more than 1V[~10kHz])
DUTY 0.1~99.9% (Pulse width / Pulse cycle) ±2.5%rdg±5dgt
Conductor size φ33Applicable standards IEC 61010-1 CAT.Ⅳ 600V IEC 61010-031
IEC 61010-2-032 IEC 61326Power source R03 (1.5V)(AAA) × 2
*Continuous measuring time : approx. 30 hours (Auto power save : approx. 15 minutes)
Dimensions 243(L) × 77(W) × 36(D) mmWeight 300g Accessories 7066A(Test leads) 9094(Carrying case) R03 × 2
Instruction manualOptional 8008(Multi-tran)(AC only)
DIG
ITA
L C
LAM
P M
ETER
S A
C
• CanmeasurelargeACcurrentupto200A.
• 24mm-diateardropshapedjaws.
• UltraSlimandlightweightHandyde-sign
• 1000AACClampMeter AC40/400/1000AAutoRange.
• φ33mmTearDropJaweasytouseintightplaces.
• DMMfunctionACV,DCV,Ω,ContinuityBuzzer.
• Fuselesselectronicprotectiononupto600V
• CAT. ⅣClampMeterscanmeasuretheVoltageandCurrent inbothverylowandhighpowercircuits.
• Thus,veryusefulforpowerdistribu-tioncompanies,powerutilitiesandmaintenancefields.
• RedLED,as“NonContactVoltage”function,giveswarningtotheuseronthepresenceofACvoltage.
• Doublemoldinggives comfortablefeelinginpalm.
• 6039countswithBarGraphdisplay.
• MIN./MAX. functionenables tokeepeasilymin.&max.valueduringmea-surement.
21
AC AØ24 MAX 200A
DATAHOLD
AUTO POWEROFF
AC A
AC A
DCAC V
DCAC V
Ω
ΩHz
Ø33
Ø33
REL
DUTY
MAX 1000A
MAX 600A
CAT.Ⅳ600V
DATAHOLD
DATAHOLD MAX/MIN
AUTO POWEROFF
AUTO POWERSAVE
400ms
10ms
DIGITAL CLAMP METERS AC/DC
KEW 2009R
MODEL 2010
KEW 2003A
2009RAC A 400.0/2000A
±1.3%rdg±3dgt (0~400A,150~1700A)(45~66Hz)±2.0%rdg±5dgt (0~400A,150~1700A)(20Hz~1kHz)±2.3%rdg±3dgt (1701~2000A)(45~66Hz)
DC A 400.0/2000A ±1.3%rdg±2dgtAC V 40.00/400.0/750V
±1.0%rdg±3dgt (45~66Hz) ±1.5%rdg±5dgt (20Hz~1kHz)DC V 40.00/400.0/1000V ±1.0%rdg±2dgt
Ω 400.0/4000Ω ±1.5%rdg±2dgtContinuity buzzer Buzzer sounds below 20ΩHz 10~4000Hz ±1.5%rdg±5dgt
(Input sensitivity Current:more than 40A Voltage:more than 10V)
Output Recorder: DC400mV against AC/DC400A DC200mV against AC/DC2000A
Conductor size φ55mm max.Applicable standards IEC 61010-1 CAT.Ⅳ 600V, CAT.Ⅲ 1000V
IEC 61010-031, IEC 61010-2-032, IEC 61326-1, IEC 61326-2-1Power source R6P (1.5V) × 2
*Continuous measuring time: approx. 15 hours (Auto power off: approx. 10 minutes)
Dimensions 250 (L) × 105 (W) × 49 (D) mmWeight Approx. 540g(including batteries)Accessories 7107A(Test leads) 8201(Output plug) 9094(Carrying case)
R6P(AA)(1.5V)x2, Instruction manualOptional 7014(Output cord) 8008(Multi-tran)(AC only)
2003AAC A 400A/2000A(0~1000A)
±1.5%rdg±2dgt[50/60Hz] ±3%rdg±4dgt[40~500Hz] ±5%rdg±4dgt[500Hz~1kHz] 2000A(1001~2000A)±3%rdg±2dgt[50/60Hz]
DC A 400/2000A ±1.5%rdg±2dgtAC V 400/750V
±1.5%rdg±2dgt[50/60Hz] ±1.5%rdg±4dgt[40Hz~1kHz]DC V 400/1000V ±1%rdg±2dgt
Ω 400/4000Ω ±1.5%rdg±2dgtContinuity buzzer buzzer sounds below 50±35ΩConductor size φ55mm max.Frequency response 40Hz~1kHzOutput Recorder: DC400mV against AC/DC400A
DC200mV against AC/DC2000AApplicable standards IEC 61010-1 CAT.Ⅳ 600V, CAT.Ⅲ 1000V
IEC 61010-031 IEC 61010-2-032Power source R6P(AA)(1.5V) ×2
*Continuous measuring time : approx. 100 hours(Auto power save : approx. 10 minutes)
Dimensions 250(L) × 105(W) × 49(D)mm Weight 530g approx.Accessories 7107A(Test leads) 8201(Output plug)
9094(Carrying case) R6P(AA) × 2 Instruction manualOptional 8008(Multi-tran)(AC only) 7256(Output cord)
2010AC A 200mA/2/20A
±1%rdg±2dgt[50/60Hz](200mA)±1.5%rdg±4dgt[40Hz~2kHz](200mA)±1%rdg±2dgt[50/60Hz](2A)±2.5%rdg±5dgt[40Hz~2kHz](2/20A)
DC A 2/20A ±1%rdg±2dgt(2A) ±1.5%rdg±4dgt(20A)
Conductor size φ7.5mm max.Frequency response DC 40Hz~2kHzOutput Recorder: DC200mV against AC200mA/2/20A
DC200mV against DC2/20APower source 6LR61(9V Alkaline battery) × 1 or AC adaptor
*Continuous measuring time : approx. 20 hours (DC)/approx. 40 hours (AC)
Dimensions 142(L) × 64(W) × 26(D)mm : Display unit153(L) × 23(W) × 18(D)mm : Sensor
Weight 220g approx.Accessories 9071(Carrying Case) 6LR61 × 1 Instruction manualOptional 8022(AC adaptor)(110V) 8023(AC adaptor)(220V)
7256(Output cord)
DIG
ITAL C
LAM
P M
ETERS A
C/D
C
• EquippedtomeasurebothACandDCcurrentwithtransformerjawsoflargediameter.
• CanmeasureACandDCcurrentsupto2000A.
• Outputterminalforconnectiontorecord-ers.
• AC/DCvoltage,resistancemeasure-mentandcontinuity functionsalsoavailable.
• TrueRMSreadinginstrumentidealforaccuratemeasurementofdistortedwaveformsandnon-sinusoidalwave-formsarisingfromthyristors.
• CanmeasureACandDCcurrentsupto2000A.
• Outputterminalforconnectiontorecorders.
• Highsensitivity,miniatureAC/DCclampmeter.
• 0.1mAminimum resolution for ACcurrentand1mAminimumresolutionforDCcurrent.
• Outputterminalforrecorderconnec-tion.
22
DCAC A DC
AC V Ω
Hz
Ø55 MAX 2000A
CAT.Ⅳ600V
CAT.Ⅳ600V
DATAHOLD
PEAKHOLD
OUT PUT
AUTO POWERSAVE
Ø55
Ø7.5
DATAHOLD
PEAKHOLD
OUTPUT
OUTPUT
AUTO POWEROFF
ExternalPower Supply
DCAC A
DCAC A
DCAC V
Ω
MAX 2000A
MAX 20A
2056R/10ms
2056R2055
2056R
2056R
2056R
10ms
DIGITAL CLAMP METERS AC/DC
www.kew-ltd.co.jp
KEW 2046R
KEW 2055/2056R
MODEL 2033
2046RAC A 0~600.0A ±2.0%rdg±5dgt(50/60Hz) ±3.5%rdg±5dgt(40~500Hz)DC A 0~600.0A ±1.5%rdg±5dgtAC V 6/60/600V(Auto Ranging)
±1.5%rdg±4dgt(50/60Hz) ±3.5%rdg±5dgt(40~400Hz)DC V 600m/6/60/600V(Auto Ranging) ±1.0%rdg±3dgt
Ω 600/6k/60k/600k/6M/60MΩ(Auto Ranging)±1%rdg±5dgt(600~6M) / ±5%rdg±8dgt(60M)
Continuity buzzer Buzzer Sounds at 100ΩHz 10/100/1k/10kHz(Auto Ranging)
(Input sensitivity Current:more than 50A[~1kHz] Voltage:more than 1V[~10kHz])
DUTY 0.1~99.9% ±2.5%rdg ±5dgt (Pulse width/Pulse cycle)
Capacitance test 400n/4µ/40µF(Auto Ranging)Temperature -50°C~+300°C(with the use of Temperature probe 8216)Conductor size φ33Applicable standards IEC 61010-1 CAT.Ⅳ 600V
IEC 61010-031, IEC 61010-2-032, IEC 61326Power source R03 (1.5V)(AAA) × 2
*Continuous measuring time : approx. 10 hours (Auto power off : approx. 15 minutes)
Dimensions 243(L) × 77(W) × 36(D) mmWeight 300gAccessories 7066A(Test leads) 9094(Carrying case) R03 × 2 Instruction manualOptional 8008(Multi-tran)(AC only) 8216(Temperature probe)
2033AC A 40/300A
±1%rdg±4dgt[50/60Hz](0~40A)±2.5%rdg±4dgt[20Hz~1kHz](0~40A)±1.5%rdg±4dgt[50/60Hz](20~200A)±2.5%rdg±4dgt[20Hz~1kHz](20~200A)±3.5%rdg[50/60Hz](200~300A)±4%rdg[20Hz~1kHz](200~300A)
DC A 40/300A ±1%rdg±4dgt(0~±40A)±1.5%rdg±4dgt(±20~±200A) ±3%rdg(±200~±300A)
Conductor size φ24mm max.Frequency response DC 20Hz~1kHzApplicable standards IEC 61010-1 CAT.Ⅲ 300V
IEC 61010-2-032Power source LR-44(1.5V) × 2
*Continuous measuring time : approx. 10 hours (Auto power save : approx. 5 minutes)
Dimensions 147(L) × 59(W) × 25(D)mmWeight 100g approx.Accessories 9090 (Carrying case)
LR-44 × 2Instruction manual
Optional 8008(Multi-tran)(AC only)
2055 2056RAC A 0~600.0/1000A
±1.5%rdg±5dgt(50/60Hz)±3.0%rdg±5dgt(40~400Hz)
0~600.0/1000A±2.0%rdg±5dgt(50/60Hz)±3.5%rdg±5dgt(40~500Hz)
DC A 0~600.0/1000A ±1.5%rdg±5dgtAC V 6/60/600V(Auto Ranging)
±1.3%rdg±4dgt(50/60Hz)±3.0%rdg±5dgt(40~400Hz)
6/60/600V(Auto Ranging)±1.5%rdg±4dgt(50/60Hz)±3.5%rdg±5dgt(40~400Hz)
DC V 600m/6/60/600V(Auto Ranging) ±1.0%rdg±3dgt
Ω 600/6k/60k/600k/6M/60MΩ (Auto Ranging)±1%rdg±5dgt(600~6M) / ±5%rdg±8dgt(60M)
Continuity buzzer Buzzer Sounds at 100ΩCapacitance test − 400n/4µ/40µF(Auto Ranging)Temperature − -50°C~+300°C
(with the use of Temperature probe 8216)
Hz 10/100/1k/10kHz(Auto Ranging)(Input sensitivity Current:more than 50A[~1kHz] Voltage:more than 1V[~10kHz])
DUTY 0.1~99.9% ±2.5%rdg ±5dgt (Pulse width/Pulse cycle)
Conductor size φ40Applicable standards IEC 61010-1 CAT.Ⅳ 600V IEC 61010-031, IEC 61010-2-032, IEC 61326Power source R03 (1.5V)(AAA) × 2
*Continuous measuring time : approx. 35 hours (Auto power save : approx. 15 minutes) (2055) *Continuous measuring time : approx. 10 hours (Auto power off : approx. 15 minutes) (2056R)
Dimensions 254(L) × 82(W) × 36(D) mmWeight 310g Accessories 7066A(Test leads) 9094(Carrying case) R03 × 2 Instruction manualOptional 8008(Multi-tran)(AC only) 8008(Multi-tran)(AC only)
8216(Temperature probe)
DIG
ITA
L C
LAM
P M
ETER
S A
C/D
C
• SmallestclampmetercapableofACandDCcurrentmeasurements.
• 300A auto ranging hasminimumresolutionof0.01AAC/DC.
• Auto-zerofunctiontoallowonetouchzeroadjustment.
• Thus,veryusefulforpowerdistribu-tioncompanies,powerutilitiesandmaintenancefields.
• RedLED,as“NonContactVoltage”function,giveswarningtotheuseronthepresenceofACvoltage.
• Doublemoldinggives comfortablefeelinginpalm.
• 6039countswithBarGraphdisplay.
• Thus,veryusefulforpowerdistribu-tioncompanies,powerutilitiesandmaintenancefields.
• RedLED,as“NonContactVoltage”function,giveswarningtotheuseronthepresenceofACvoltage.
• Doublemoldinggives comfortablefeelinginpalm.
• 6039countswithBarGraphdisplay.
23
photo : 2056R
DCAC AØ24
Ø33
MAX 300A
DATAHOLD
AUTO POWERSAVE
DCAC V DC
AC AΩ Hz
DATAHOLD
PEAKHOLD
AUTO POWEROFF
AUTO POWERSAVE
AUTO POWEROFF
MAX/MIN REL
DUTY
°C
CAT.Ⅳ600V
MAX 600A
Ø40 DCAC V DC
AC A
Ω Hz
DATAHOLD
PEAKHOLD MAX/MIN REL
DUTY
°C
CAT.Ⅳ600V
MAX 1000A
KEW FORK CURRENT TESTER
DC MILLIAMP CLAMP METER
DC MILLIAMP CLAMP METER/FORK CURRENT TESTER
MODEL 2300R
KEW 2500
2300RCurrentmeasurement
AC A 0~100.0A ±2.0%rdg±5dgt (50/60Hz) DC A 0~±100.0A ±2.0%rdg±5dgt
Crest factor 2.5Non contactvoltage
Detect AC voltage without contacting with socket wireDuring voltage detection, “Hi” flashes and a buzzer sounds
Maximum digit 1,049Conductor size Max φ10mm Applicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2Power source R03 (AAA) × 2 (Auto power off : approx. 10 minutes)
*Continuous measuring time : AC A approx. 46 hours DC A approx. 52 hours
Dimensions 161.3(L) × 40.2(W) × 30.3(D)mmWeight 110g (including batteries)Accessories 9113(Carrying case) R03 (AAA) × 2 Instruction manual
DC
MILLIA
MP
CLA
MP
METER
/FOR
K C
UR
REN
T TESTER
• 0.01mAresolutionforDCcurrent
• Topclassmeasurement0.2%accuracy
• Ø6mmclampjaweasytouseintightplaces
• Measurementfrom0.01mAto120.0mA
• DualdisplaywithbacklightshowsbothmAmeasurementandpercentof4-20mAspan
• Spotlightforilluminatingmeasurementpoint
• Analogoutputterminalforrecorderconnection
• ComplieswithIEC61010-1CAT.Ⅱ 300V
• TrueRMSreading isanessential featureforaccuratemeasurement.
• "NonContact"voltage function indicatesthepresenceofACvoltagebywarningtheuserwithanaudiblesignal.
• Set theDCcurrent range to zero inonetouchwiththeZeroAdjustfunction.
• AutoPowerOff.
KEWFORK2300Rcanbeusedincrowdedconnectionboxes,wherecablesareveryshort,andspaceistoolimitedtoclampcablesusingwithatraditionalclampmeter.
Recorder or Logger
MODEL7256Output cord(Optional)
DC10mV/DC1mA
φ6mm
NEW
24
Digital Multimeter
Analog output terminal for recorder connection
Dual display gives simultaneous readout of % values and measured values(mA)
measured values (mA) % values
Note: The Auto-power OFF can be disabled for long recording
Diameter of measurable conductor : φ6mm max
2500DC A 20/100mA(Auto ranging)
±0.2%rdg±5dgt(0.00mA~21.49mA)±1.0%rdg±5dgt(21.0mA~120.0mA)
Conductor size φ6mm max.Analog output Recorder: DC1000mV against DC100mAWithstand voltage 2210V AC for 5 secondsApplicable standards IEC 61010-1, 61010-2-030 CAT.Ⅱ 300V
IEC 61010-2-032IEC 61326-1, 61326-2-2IEC 60529 IP40
Operating temperature &humidity -10~+50°C < 85%Storage temperature & humidity -20~+60°C < 85%Power source R6/LR6(AA) (1.5V) × 4Dimensions 111(L) × 61(W) × 40(D)mm : Display unit
104(L) × 34(W) × 20(D)mm : Sensor700mm : Sensor cable
Weight Approx. 290g (including batteries)Accessories 9096(Carrying case) LR6(AA) × 4
Instruction manual, Calibration certificateOptional 7256(Output cord)
DC AØ6 DATAHOLD
DATAHOLD
OUT PUT
AUTO POWEROFF
Ø10 AUTO POWEROFF
DCAC AMAX
100A
High Sensitive Model
2433R
10ms
10ms
LEAKAGE CLAMP METERS
www.kew-ltd.co.jp
MODEL 2432
MODEL 2433/2433R
MODEL 2431
2432AC A (50/60Hz)
4/40mA/100A ±1%rdg±5dgt(4/40mA) ±1%rdg±5dgt(0~80A)±5%rdg(80.1~100A)
AC A (WIDE)
4/40mA/100A±1%rdg±5dgt[50/60Hz] ±2.5%rdg±10dgt[20Hz~1kHz](4/40mA)±1%rdg±5dgt[50/60Hz] ±2.5%rdg±10dgt[40Hz~1kHz](0~80A)±5%rdg[50/60Hz] ±10%rdg[40Hz~1kHz](80.1~100A)
Maximumcircuit voltage
600V AC/DC (between line/neutral)300V AC/DC (against earth)
Conductor size φ40mm max.Frequency response 20Hz~1kHz(40Hz~1kHz:100A)Effect of externalstray magnetic field
2mA AC approx. in proximity to a 15mm-diaconductor carrying 100A AC
Applicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2IEC 61010-2-032
Power source R03(DC1.5V) × 2 *Continuous measuring time : approx. 40 hours (Auto power off : approx. 10 minutes)
Dimensions 185(L) × 81(W) × 32(D)mmWeight 290g approx.Accessories 9097(Carrying case) R03(1.5V) × 2 Instruction manualOptional 8008(Multi-tran) *
*These Multi-trans can not be used for leakage current measurement.
2431AC A(50/60Hz)
20/200mA/200A±3%rdg±5dgt(20/200mA/100A)±5%rdg±5dgt(200A)
AC A (WIDE)
20/200mA/200A±2%rdg±4dgt[50/60Hz](20/200mA/0~100A)±5%rdg±6dgt[40~400Hz](20/200mA/0~100A)±5%rdg±4dgt[50/60Hz](100.1~200A)
Conductor size φ24mm max.Frequency response 40~400HzEffect of external stray magnetic field φ15mm 100A
10mA AC max.
Applicable standards IEC 61010-1 CAT.Ⅲ 300V IEC 61010-2-032Power source LR-44(1.5V) × 2
*Continuous measuring time : approx. 15 hours (Auto power off : approx. 10 minutes)
Dimensions 149(L)× 60(W) × 26(D)mmWeight 120g approx.Accessories 9090 (Carrying case)
LR-44 × 2Instruction manual
Optional 8008(Multi-tran)*
*These Multi-trans can not be used for leakage current measurement.
2433/2433RAC A(50/60Hz)
40/400mA/400A±1%rdg±5dgt(40/400mA)±1%rdg±5dgt(0~350A:2433, 0~300A:2433R)±2%rdg(350.1~399.9A:2433, 300.1~399.9A:2433R)
AC A(WIDE)
40/400mA/400A±1%rdg±5dgt[50/60Hz] ±2.5%rdg±10dgt[20Hz~1kHz](40/400mA)±1%rdg±5dgt[50/60Hz] ±2.5%rdg±10dgt[40Hz~1kHz](0~350A:2433, 0~300A:2433R)±2%rdg[50/60Hz] ±5%rdg[40Hz~1kHz](350.1~399.9A:2433, 300.1~399.9A:2433R)
Maximum circuit voltage 600V AC/DC (between line/neutral) 300V AC/DC (against earth)Conductor size φ40mm max.Frequency response 20Hz~1kHz(40Hz~1kHz:400A)Effect of externalstray magnetic field
10mA AC approx. in proximity to a 15mm-diaconductor carrying 100A AC
Applicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2 IEC 61010-2-032Power source R03 (DC1.5V) × 2
*Continuous measuring time : approx. 40 hours (2433) *Continuous measuring time : approx. 24 hours (2433R) (Auto power off : approx 10 minutes)
Dimensions 185(L) × 81(W) × 32(D)mmWeight 270g approx. Accessories 9097 (Carrying case) R03(1.5V) × 2 Instruction manualOptional 8008 (Multi-tran)*
*These Multi-trans can not be used for leakage current measurement.
LEA
KA
GE
CLA
MP
MET
ERS
• FrequencySelectorSwitch toelimi-natetheeffectofharmonics.
• Autopower-offfunction
• Rotary switch for easy one fingerpower-onandrangeselection.
• FrequencySelectorSwitch toelimi-natetheeffectofharmonics.
• Threeranges:4mA/40mA/100A.
• FrequencySelectorSwitch toelimi-natetheeffectofharmonics.
• Threeranges:40mA/400mA/400A.
25
photo : 2433R
AC AØ24AUTO POWER
OFF
AUTO POWEROFF
Ø40
MAX 200A
Resolution0.01mA
DATAHOLD Filter
FilterAC A DATA
HOLDPEAKHOLD
MAX 100A
Ø40 AC AAUTO POWER
OFF
DATAHOLD
PEAKHOLD Filter
MAX 400A
Resolution0.001mA
Resolution0.01mA
2413R
2413R
10/100ms
LEAKAGE CLAMP METERS
MODEL 2412
MODEL 2434
KEW 2413F/2413R 2413F 2413RAC A(50/60Hz)
200mA/2/20/200A/1000A ±1.5%rdg±2dgt(200mA/2/20A)±2%rdg±2dgt(200A/0~500A) ±5.5%rdg(501~1000A)
200mA/2/20/200/1000A±2.5%rdg±5dgt(200mA/2/20A)±3.0%rdg±5dgt(200A/0~500A)±5.5%rdg(501~1000A)
AC A(WIDE)
200mA/2/20/200A/1000A ±1%rdg±2dgt[50/60Hz] ±3%rdg±2dgt[40Hz~1kHz](200mA/2/20A)±1.5%rdg±2dgt[50/60Hz] ±3.5%rdg±2dgt[40Hz~1kHz](200A/0~500A)±5%rdg[50/60Hz] ±10%rdg[40Hz~1kHz](501~1000A)
200mA/2/20/200/1000A±1.8%rdg±5dgt[50/60Hz]±3.0%rdg±5dgt[40Hz~1kHz](200mA/2/20A)±2.0%rdg±5dgt[50/60Hz]±3.5%rdg±5dgt[40Hz~1kHz](200A/0~500A)±5.0%rdg[50/60Hz](501~1000A)
Conductor size φ68mm max.Frequency response 40Hz~1kHzEffect of external straymagnetic field φ15mm 100A
10mA AC max.
Output Waveform:AC200mV against the maximum value of each range (1000A range is 100mV)Recorder:DC200mV against the maximum value of each range (1000A range is 100mV)
Crest factor — 3.0 or LessApplicable standards IEC 61010-1 CAT.Ⅲ 300V IEC 61010-2-032Power source 6F22(9V) × 1 *Continuous measuring time : approx. 60 hours
Dimensions 250(L) × 130(W) × 50(D)mmWeight 570g approx. 600g approx.Accessories 9094(Carrying case) 6F22 × 1 Instruction manualOptional 7073(2WAY Output cord)
2412AC A(50/60Hz)
20/200mA/2/20/200/500A ±1.5%rdg±5dgt(20/200mA/2A) ±2%rdg±5dgt(20/200A) ±2.5%rdg±5dgt(500A)
AC A(WIDE)
20/200mA/2/20/200/500A ±1%rdg±3dgt[50/60Hz] ±5%rdg±5dgt[40~400Hz](20/200mA/2A)±1.5%rdg±3dgt[50/60Hz] ±5%rdg±5dgt[40~400Hz](20/200A)±2%rdg±3dgt[50/60Hz] ±5%rdg±5dgt[40~400Hz](500A)
AC V 600V ±2%rdg±5dgt[50/60Hz] ±5%rdg±5dgt[40~400Hz]
Ω 200Ω ±1.5%rdg±5dgtConductor size φ40mm max. Frequency response 40~400HzEffect of external straymagnetic field φ15mm 100A
10mA AC max.
Output Recorder:DC200mV against the maximum value of each range (500A range is 50mV)
Power source 6F22(9V) × 1 or AC adaptor*Continuous measuring time : approx. 100 hours (Auto power off : approx. 60 minutes)
Dimensions 209(L) × 96(W) × 45(D)mmWeight 450g approx.Accessories 7066A(Test leads) 9072(Carrying case)
8025(Output plug) 6F22 × 1 Instruction manual Optional 8008(Multi-tran)* 8022(AC adaptor)(110V)
8023(AC adaptor)(220V) 7256(Output cord)
*These Multi-trans can not be used for leakage current measurement.
2434AC A(50/60Hz)
400mA/4/100A±2%rdg±4dgt
AC A(WIDE)
400mA/4/100A±2%rdg±4dgt[50/60Hz] ±3%rdg±5dgt[40~400Hz]
Conductor size φ28mm max. Frequency response 40~400Hz Effect of external straymagnetic field φ15mm 100A
20mA AC max.
Applicable standards IEC 61010-1 CAT.Ⅲ 300V IEC 61010-2-032Power source R03(AAA) (1.5V) × 2
*Continuous measuring time : approx. 150 hours(Auto power save : approx. 10 minutes)
Dimensions 169(L) × 75(W) × 40(D)mmWeight 220g approx.Accessories 9097(Carrying case) R03 × 2 Instruction manualOptional 8008(Multi-tran)*
*These Multi-trans can not be used for leakage current measurement.
LEAK
AG
E CLA
MP
METER
S
• Large tranceformer jawsof68mmdiametermakesitpossibletoclamponall threeorfourwires(3phases)together for leakagecurrent mea-surement.
• Frequencyfilterswitchtoeliminatetheeffectoftheharmonics.
• 2wayanalogueoutputterminal.
• Digital clampmeterwith teardropshaped,medium size transformerjawsspeciallydesigned for leakagecurrentmeasurement.
• Frequency filterswitch toeliminatetheeffectofharmonics.
• Leastaffectedbyexternalstraymag-neticfield.
• 20mA ACmax. in proximit y to a15mm-diaconductorcarrying100AAC.
• FrequencySelectorSwitch toelimi-natetheeffectofharmonics.
26
photo : 2413R
AC AØ68 MAX 1000A
DATAHOLD
PEAKHOLD
OUT PUT
Ø40
Ø28AUTO POWER
SAVE
DATAHOLD
OUTPUT
DATAHOLD
AUTO POWEROFF
Filter
AC A
AC A
AC V ΩMAX 500A
Resolution0.01mA
MAX 100A
Resolution0.1mA
Resolution0.1mA
ExternalPower Supply
Filter
Filter
CLAMP SENSORAC DC
MULTI-TRAN
CLAMP SENSOR/CLAMP ADAPTOR/MULTI-TRAN
www.kew-ltd.co.jp
MODEL 8112/8112BNC
MODEL 8008
KEW 8115
8112/8112BNCRange Measuring ranges Output voltage Accuracy Frequency response200mA AC 0~500mA AC1V/A
(1000mA1V)±1.5%rdg±0.2mA 50Hz~1kHz
AC 0~1000mA ±3%rdg±0.4mA 40Hz~10kHz2A AC 0~20A AC100mV/A
(20A2V)±1%rdg±1mA 40Hz~1kHz±1.5%rdg±2mA 1k~10kHz
20A AC 0~20AAC10mV/A (120A1.2V)
±1%rdg±0.01A 40Hz~1kHzAC 20~60A ±2.5%rdg 50Hz~10kHzAC 60~120A ±2.5%rdg 100Hz~10kHz
Conductor size φ8mm max. Frequency response 30Hz~100kHz(-3dB) Applicable standard IEC 61010-1 CAT.Ⅱ
100V Pollution degree 2(8112 Only).Dimensions 153(L) × 18(W) × 23(D)mmWeight 100g approx.Accessories 9057(Carrying case)
Instruction manual
8115Measuring range AC 0.1~130Arms DC 0~±180AOutput voltage AC 10mV/A DC 10mV/AAccuracy ±1.2%rdg±0.4mV (50/60Hz)
±2.5%rdg±0.4mV (40Hz~1kHz)±1.2%rdg±0.4mV (*)
Low battery warning 2.2V±0.2V or less - Red LED flash(1.9V±0.2V - Automatically power off)
Conductor size φ12mm max. Operating tempera-ture & humidity range
-10 to 55ºC, relative humidity 85% or less (no condensation)
Output impedance Approx. 10Ω or lessApplicable standards
IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2,IEC 61010-2-032, IEC 61326-1
Power source DC3V (size AAA alkaline battery LR03×2pcs)Continuous use: approx. 40 hours(Auto power off: approx. 20 minutes)
Cord length Approx. 1,200mmOutput connector φ4mm banana plugDimensions 127(L)×42(W)×22(D) mmWeight Approx. 140gAccessories Soft case, LR03×2, Instruction manual
*This accuracy is defined after the completion of the KEW 8115 zero-adjustment whilst connected to a DMM.
8008Measuring range 0~3000A ACRatio/Range 10 : 1 (input to output)Accuracy ±2% of input±0.5AAllowablemeasurement time
0~1000A(continuous) 1000~1500A(10 minutes max.)3000A(30 seconds max.)
Conductor size φ100mm max.(100 × 150mm)Frequency response 50Hz/60HzSafety standard IEC 61010-1 CAT.Ⅲ300V
Pollution degree 2Dimensions 317(L) × 150(W) × 30(D)mm
45(L) × 40(W) × 10(D)mm Output coilWeight 750g approx.Accessories 9056(Carrying case)
*These Multi-trans can not be used for leakage current measurement.
CLA
MP
SEN
SOR
/CLA
MP
AD
AP
TOR
/MU
LTI-
TRA
N
Model8112clampadaptor isdesignedtobeanACcurrent/voltageconversionprobeca-pableofmeasuringACcurrentfrom0.1mAto120Ainconjunctionwithdigitalmultimeters.
Model8112BNCisanACclampadaptordesignedforusewithoscilloscopes.OutputcordhasaBNCconnectorwhichenablesdirectobservationofcurrentwaveformonoscillo-scope.SpecificationsaresameasthoseforModel8112.
Adaptordesignedto increasethemea-suringcapabilityofyourclampmeters.With theuseof themulti-tranyoucannotonlyextendcurrentrangesbutalsoclamponaconductorof largerdiam-eter.
• Permitsextensionof theACandDCcurrentrangesofalmostanyDigitalMultimeters(DMMs)withoutbreakingthecircuitundertest.
• UsingKEW8115withKEW1051/1052(DMM)thedisplaycanbesetfordirectreadinginA.
8112 8112BNC
27
photo : 8112
Ø8
Ø100
MAX 120A
MAX 3000A
Ø12 DCAC A AUTO POWER
OFFMAX 130A
MAX 180A
AC A
AC A
INSULATION TESTERS
INSULATION TESTERS
INSU
LATIO
N TESTER
S
28
Selection Guide of Insulation Testers
Analogue Insulation Testers Analogue Insulation/Continuity Testers
3165 3166 3161A 3321A 3131A 3132A
Appearance
Test voltage 1 range 2 ranges 3 ranges
Rated voltage(Max.effective scale value) 500V(1000MΩ) 1000V(2000MΩ) 15V(20MΩ)
500V(100MΩ)
250V(50MΩ) 500V(100MΩ)
1000V(2000MΩ)
250V(100MΩ) 500V(200MΩ)1000V(400MΩ)
250V(100MΩ) 500V(200MΩ)1000V(400MΩ)
Continuity Ω − − − − 2/20Ω 3/500Ω
AC Voltage AC V 600V 600V 600V 600V − 600V
Back light − − −
Power source R6P x 4 R6P x 4 R6P x 4 R6P x 6 R6P x 6 R6P x 6
Dimensions(L)x(W)x(D)mm
90x137x40 90x137x40 90x137x40 105x158x70 185x167x89 106x160x72
Weight(Approx.) 330g 330g 340g 520g 860g 560g
Digital Insulation/Continuity Testers
3001B 3005A 3007A 3021 3022 3023
Appearance
Test voltage 2 ranges 3 ranges 4 ranges
Rated voltage(Max.effective scale value)
500V(200MΩ)1000V(200MΩ)
250V(20MΩ)500V(200MΩ)
1000V(2000MΩ)
250V(20MΩ)500V(200MΩ)
1000V(2000MΩ)
125V(200MΩ) 250V(2000MΩ)500V(2000MΩ) 1000V(2000MΩ)
50V(200MΩ) 100V(200MΩ)
250V(2000MΩ) 500V(2000MΩ)
100V(200MΩ) 250V(2000MΩ)500V(2000MΩ) 1000V(2000MΩ)
Continuity Ω 200Ω 20/200/2000Ω 20/200/2000Ω 40/400Ω 40/400Ω 40/400Ω
Continuity buzzer −
AC Voltage AC V − 600V 600V 20~600V 20~600V 20~600V
DC Voltage DC V − − −-20~-600V20~600V
-20~-600V20~600V
-20~-600V20~600V
Back light − −
Power source R6P x 8 R6P x 8 R6P x 8 R6P x 6 R6P x 6 R6P x 6
Dimensions(L)x(W)x(D)mm 144x93x61 185x167x89 185x167x89 105x158x70 105x158x70 105x158x70
Weight(Approx.) 460g 970g 990g 600g 600g 600g
Analogue High Voltage Insulation Testers Digital High Voltage Insulation Testers
3121A 3122A 3123A 3124 3125 3126 3128
Appearance
Test voltage 1 range 2 ranges Variable 4 ranges 6 ranges (Variable)
Rated voltage(Max.effective scale value) 2500V(100GΩ) 5000V(200GΩ) 5000V(200GΩ)
10000V(400GΩ)1000V(100MΩ)
1k~10kV(100GΩ)
500V(999MΩ) 1000V(1.99GΩ)2500V(99.9GΩ)
5000V(1TΩ)
500V(999MΩ) 1000V(1.99GΩ)2500V(99.9GΩ)
5000V(1TΩ)
500V(500GΩ) 1000V(1TΩ)
2500V(2.5TΩ) 5000V(5TΩ)
10000V(35TΩ) 12000V(35TΩ)
AC/DC Voltage DCAC V − − − − 30~600V AC/DC 30~600V AC/DC 30~600V AC/DC
Back light − − − −
Current − − − − − − 0.00nA~2.40mA
Capacitance − − − − − − 5.0nF~50.0µF
Power source R6P x 8 R6P x 8 R6P x 8 Ni-Cd rechargeable battery(1.2V) x 8 LR14 x 8 LR14 x 8 Rechargeable lead
storage battery (12V)Dimensions(L)x(W)x(D)mm 200x140x80 200x140x80 200x140x80 200x140x80 205x152x94 205x152x94 330x410x180
*Instrument and Hard case
Weight(Approx.) 1000g 1000g 1000g 1500g 1800g 1800g 9000g
INSULATION TESTERS
www.kew-ltd.co.jp
INSU
LATI
ON
TES
TER
S
29
photo:3165
photo:3021
photo:3123A
Features (3005A/3007A)
Accessory
MODEL 7122BTest leads
Selection Guide
DIGITAL INSULATION/CONTINUITY TESTERS
MODEL 3005A
MODEL 3007A
MODEL 3001B 3001BInsulation resistance
Test voltage 500V/1000VMeasuring ranges 200MΩ(2/20/200MΩ) autorangingOutput voltage on open circuit Rated test voltage +12%Rated current 1~1.1mA DC approx.Output short circuit current 1.5mA DC approx.Accuracy ±2%rdg±1dgt
Continuity testMeasuring ranges 200Ω(20/200Ω) autorangingOutput voltage on open circuit 600mV DC approx.Output short circuit current 6mA approx.Accuracy ±2%rdg±0.1Ω±1dgt
GeneralPower source R6P(AA)(1.5V) × 8Dimensions 144(L) × 93(W) × 61(D)mmWeight 460g approx.Accessories 7025(Test leads) 9050(Carrying case) R6P(AA) × 8
Instruction manual
3005A/3007AInsulation resistance
Test voltage 250V/500V/1000VMeasuring ranges 20MΩ/200MΩ/2000MΩOutput voltage on open circuit Rated test voltage +20%, -0%Nominal current 1mA DC min.Output short circuit current 1.5 mA DC approx.Accuracy ±1.5%rdg±5dgt(20MΩ/200MΩ) ±10%rdg±3dgt(2000MΩ)
Continuity testMeasuring ranges 20Ω/200Ω/2000ΩOutput voltage on open circuit 7~12V DCMeasuring current 200mA DC min.Accuracy ±1.5%rdg±5dgt(20Ω) ±1.5%rdg±3dgt(200Ω/2000Ω)
AC voltageAC voltage range 0~600V ACAccuracy ±5%rdg±3dgt
GeneralApplicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2
IEC 61010-031 IEC 61557-1/2/4IEC 60529(IP54) IEC 61326-1(EMC)
Power source R6P(AA)(1.5V) × 8Dimensions 185(L) × 167(W) × 89(D)mmWeight 990g approx.(3007A)
970g approx.(3005A)Accessories 7122B(Test leads) 9074(Cord case)
8923(Fuse[F500mA/600V] ) × 2R6P(AA) × 8 9121(Shoulder strap)Instruction manual
3005A 3007A250V test voltage
500V test voltage
1000V test voltage
200mA continuity range
Live circuit warning
Illuminated scale
Automatic discharge
Trac-lok for extended battery life
DIG
ITAL IN
SULA
TION
/CO
NTIN
UIT
Y TESTER
S
30
• Bargraphtodisplayinsulationresistance.
• DisplaysthevalueofexternalACvoltagealongwithflashingsymbol.
• Autonullfunctiontoautomaticallysubtractthetest leadresistancebeforedisplayingtherealcontinuityresistancevalue.
• Trac-Lokmodetoconservebatterylifeoninsulationandcontinuitytests(Model3007Aonly).
• Livecircuitwarningbeeper.
• Releasingthetestbuttonautomaticallydischargesthechargesstored inthecircuitundertest.
• Backlightfunctiontoviewthetestresultsindimlylitareas(Model3007Aonly).
• 200mAcontinuitymeasuringcurrenttoIEC61557.
• Minimum1mAcurrentoninsulationteststoIEC61557.
Ω
Ω
Ω
AC V
AC V
AUTO POWEROFF
AUTO POWEROFF
Optional Accessories
MODEL 8016Hook type prod
Accessories
MODEL 7115/7116Extension probe
7149A(7139A)
7150A(7103A)
7115
7116
MODEL 3161A
MODEL3321AKEW 3021, 3022, 3023
MODEL 9089Carrying case
MODEL 7149A/7150A Test leads with remote control switch set(7103A or 7139A, 7161A, 7131B, 8017, 9120 or 9041)
DIGITAL INSULATION/CONTINUITY TESTERS
www.kew-ltd.co.jp
KEW 3021/3022/3023
3021 3022 3023Insulation resistance
Test voltage 125V 250V 500V 1000V 50V 100V 250V 500V 100V 250V 500V 1000VMeasuring range(Auto range)
4.000/40.00/200.0MΩ
4.000/40.00/400.0/2000MΩ 4.000/40.00/200.0MΩ 4.000/40.00/400.0/2000MΩ 4.000/40.00/200.0MΩ
4.000/40.00/400.0/2000MΩ
First effective measuring range 0.1~20MΩ 0.1~40MΩ 0.1~200MΩ 0.1~1000MΩ 0.1~20MΩ 0.1~40MΩ 0.1~200MΩ 0.1~20MΩ 0.1~40MΩ 0.1~200MΩ 0.1~1000MΩMid-scale value 5MΩ 50MΩ 5MΩ 50MΩ 5MΩ 50MΩAccuracy ±2%rdg±6dgtSecond effectivemeasuring range lower
0~0.099MΩ
Second effectivemeasuring range upper
20.01~200.0MΩ
40.01~2000MΩ
200.1~2000MΩ
1001~2000MΩ
20.01~200.0MΩ
40.01~2000MΩ
200.1~2000MΩ
20.01~200.0MΩ
40.01~2000MΩ
200.1~2000MΩ
1001~2000MΩ
Accuracy ±5%rdg±6dgRated current DC 1~1.2mAOutput short circuit current 1.5mA max
Ω/ContinuityAuto range 40.00/400.0ΩAccuracy ±2%rdg±8dgtOutput voltage on open circuit 5V±20%Output short circuit current DC 220±20mAFuse Quick acting ceramic fuse 0.5A/600V(φ6.35×32mm)
AC voltageRange AC 20~600V(50/60Hz) DC −20~−600V/+20~+600VAccuracy ±3%rdg±6dgt
GeneralApplicable standards IEC 61010-1 CAT.Ⅲ 600V IEC 61557-1,2,4 IEC 61326-1(EMC) IEC 60529(IP40)Dimensions / Weight 105(L) × 158(W) × 70(D)mm / 600g approx.Power source R6P×6 or LR6×6Accessories 7150A(Test Lead with remote control switch set) 9121(Shoulder strap) R6P(AA) × 6 Instruction manualOptional 7115(Extension probe) 8016(Hook type prod) 8923(Fuse[0.5A/600V]) 9089(Carrying case)
DIG
ITA
L IN
SULA
TIO
N/C
ON
TIN
UIT
Y T
ESTE
RS
31
• 3functionsinoneunit,insulationtestwith4voltageranges,continuitytest, ACvoltagemeasurement.
• 200mAmeasuringcurrentoncontinuitytesting.
• ComparatorfunctionwithPASS/FAILandbuzzer.
• 0Ωadjustmentatcontinuitymeasuringrange.
• Memoryfunctionupto99data.
• BacklightLCDprovideseasyreadingindarklocations.
• Safetylocksystempreventsanerroneousoperation
photo : 3021
ΩDCAC V AUTO POWER
OFF
Accessory
MODEL 7122BTest leads
Selection Guide
ANALOGUE INSULATION/CONTINUITY TESTERS
MODEL 3132A
MODEL 3131A 3131A Insulation resistance
Test voltage 250V/500V/1000VMeasuring ranges (Mid-scale value)
100MΩ/200MΩ/400MΩ (1MΩ) (2MΩ) (4MΩ)
Output voltage on open circuit Rated test voltage +20%, -0%Nominal current 1mA DC min.Output short circuit current 1.3 mA DC approx.Accuracy 0.1~10MΩ/0.2~20MΩ/0.4~40MΩ
(Accuracy guaranteed ranges) ±5% of indicated valueContinuity
Measuring ranges (Mid-scale value)
2Ω/20Ω(1Ω)(10Ω)
Output voltage on open circuit 4~9V DCMeasuring current 200mA DC min.Accuracy ±3% of scale length
General Applicable standards
IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2IEC 61010-031 IEC 61557-1/2/4 IEC 60529(IP54) IEC 61326-1(EMC)
Power source R6P(AA)(1.5V) × 6Dimensions 185(L) × 167(W) × 89(D)mmWeight 860g approx.Accessories 7122B(Test leads) 9074(Cord case)
8923(Fuse[0.5A/600V]) × 2R6P(AA) × 6 9121(Shoulder strap) Instruction manual
3132A Insulation resistance
Test voltage 250V/500V/1000VMeasuring ranges (Mid-scale value)
100MΩ/200MΩ/400MΩ (1MΩ) (2MΩ) (4MΩ)
Output voltage on open circuit
Rated test voltage +20%, -0%
Nominal current 1mA DC min.
Output short circuit current 1~2mA DCAccuracy 0.1~10MΩ/0.2~20MΩ/0.4~40MΩ
(Accuracy guaranteed ranges) ±5% of indicated valueContinuity
Measuring ranges(Mid-scale value)
3Ω/500Ω(1.5Ω/20Ω)
Output voltage on open circuit 4.1V DC approx.Measuring current 210mA DC min.Accuracy ±1.5% of scale length
AC voltageAC voltage range 0~600V ACAccuracy ±5% of scale length
GeneralApplicable standards
IEC 61010-1 CAT.Ⅲ 600V Pollution degree 2IEC 61010-031 IEC 61557-1/2/4IEC 60529(IP54) IEC 61326-1(EMC)
Power source R6P(AA)(1.5V) × 6Dimensions 106(L) × 160(W) × 72(D)mmWeight 560g approx.Accessories 7122B(Test leads) 9074(Cord case)
8923(Fuse[0.5A/600V]) × 2R6P(AA) × 6 9121(Shoulder strap) Instruction manual
3131A 3132A3 range insulation test voltage
200mA continuity
Live circuit warning
AC voltage range
Illuminated scale
Automatic discharge
IP54 rate
AN
ALO
GU
E INSU
LATIO
N/C
ON
TINU
ITY
TESTERS
32
• Testinsulationupto100MΩat250V,200MΩat500V,400MΩat1000Vandcontinuityupto20Ω.
• LIVEcircuitwarninglampplusaudiblewarning.
• AutomaticdischargeofcircuitcapacitancewhenTESTbuttonisreleased.
• Fuseprotected(continuityrangeonly).
• BatterycheckLED.
• Frontpanelzeroadjust.
• Backlightfunctiontofacilitateworkingatdimlylitsituations.
• PRESSTOTESTbuttonwithlockdownfeature.
• Dustanddripproofconstruction.(designedtoIEC60529IP54)
• DesignedtomeetIEC61010-1andIEC61557safetystandard.
• 1mAratedtestcurrentattheminimumresistance.
• 200mAmeasuringcurrentoncontinuitytesting.
• Automaticdischargeofcircuitcapacitance. (Anychargestoredinthecircuitundertestwillbeautomaticallydischargedaftertesting.)
• Livecircuitwarningbuzzerandneonlamp.
• Smallandlightweight.Shockresistantnewcasematerial.
• ACvoltmeterwithlinear,easy-to-readscale.
• OperatesonAA,R6P×6drybatteries.
Ω
ΩAC V
ANALOGUE INSULATION TESTERS
www.kew-ltd.co.jp
MODEL 3161A
MODEL 3165/3166
MODEL 3321A
3161AInsulation resistance
Test Voltage 15V/500VMax. effective scale value 20MΩ/100MΩMid-scale value 0.05MΩ/2MΩFirst effective measuring ranges
0.005~2MΩ/0.1~50MΩ
Accuracy ±5% of indicated valueSecond effectivemeasuring ranges
Measuring ranges other than above, O and ∽
Accuracy ±10% of indicated valueAC voltage
AC voltage range 600VAccuracy ±3% of full scale value
Applicable standards IEC 61010-1 CAT.Ⅲ 300V, CAT.Ⅱ600VPower source R6P(AA)(1.5V) × 4Dimensions 90(L) × 137(W) × 40(D)mmWeight 340g approx.Accessories 7149A(Test leads with remote control switch set)
9123(Shoulder strap)R6P(AA) × 4 Instruction manual
Optional 7116(Extension probe) 8016(Hook type prod)
3321AInsulation resistance
Test Voltage 250V/500V/1000VMax. effective scalevalue
50MΩ/100MΩ/2000MΩ
Mid-scale value 1MΩ/2MΩ/50MΩFirst effective measuring ranges
0.05~20MΩ(250V) 0.1~50MΩ(500V) 2~1000MΩ(1000V)
Accuracy ±5% of indicated valueSecond effectivemeasuring ranges
20~50MΩ(250V) 50~100MΩ(500V) 1000~2000MΩ(1000V)
Accuracy ±10% of indicated valueAC voltage
AC voltage range 600VAccuracy ±3% of full scale value
Applicable standards IEC 61010-1 CAT.Ⅲ600V, CAT.Ⅱ1000VPower source R6P(AA)(1.5V) × 6Dimensions 105(L) × 158(W) × 70(D)mmWeight 520g approxAccessories 7150A(Test lead with remote control switch set)
9121(Shoulder strap) 7081B(Guard cord): 3321A onlyR6P(AA) × 6 Instruction manual7115(Extension probe) 8016(Hook type prod)
Optional 9089(Carrying case)
3165 3166Insulation resistance
Test voltage 500V 1000VMax. effective scale value 1000MΩ 2000MΩMid-scale value 20MΩ 50MΩFirst effective measuring range
1~500MΩ 2~1000MΩ
Accuracy ±5% rdgSecond effectivemeasuring range
0.5/1000MΩ 1/2000MΩ
Accuracy ±10% rdgAC voltage
AC voltage range 600VAccuracy ±3% of full scale value
Power source R6P(AA)(1.5V) × 4Dimensions 90(L) × 137(W) × 40(D)mmWeight 330g approx.Accessories 7025(Test leads) 9074(Cord case) 9123(Shoulder strap)
R6P(AA) × 4 Instruction manual
AN
ALO
GU
E IN
SULA
TIO
N T
ESTE
RS
33
• Miniaturelightweightinsulationtester.Itweighsonly340g(batteryincluded),butcar-riesfullmeasurementfunctions.
• Automaticdischargeofcircuitcapacitance.
• Testleadswithremotecontrolswitch.
• Newrobusthousingcase.
• Backlightfunction.
• 500V/1000MΩ(Model3165)
• 1000V/2000MΩ(Model3166)
• Expandedmegohmscaleforeasyreading.
• Newrobusthousingcasetopreventdamage.
• ACvoltmeterscaleforeasyreading.
• Autodischargefunction;anychargestoredinthecircuitundertestwillbeautomati-callydischargedaftertesting.
• DesignedtomeetIEC61010-1CAT.Ⅲ600V,CAT.Ⅱ1000V
• Color-codedscalesforeasyreading.
• Backlightfunctiontofacilitateworkingatdimlyilluminatedlocations.
• Testleadsetwithremotecontrolswitch.
• Shoulderstrapforhandsfree.
photo : 3165
AC V
AC V
AC V
Optional Accessories
MODEL 8019Hook type prod
MODEL 8324Adaptor for recorder(Output 10mV/1µA)
Cable length:200mm connector side
1100mm alligator clip side
MODEL 7253Longer line probe
with alligator clip:15m
Selection Guide
HIGH VOLTAGE INSULATION TESTERS
MODEL 3124
KEW 3121A/3122A/3123A 3121A 3122A 3123ATest voltage 2500V 5000V 5000V 10000VMeasuring ranges(automatic change)
2GΩ/100GΩ(autoranging)
5GΩ/200GΩ(autoranging)
5GΩ/200GΩ (autoranging)
10GΩ/400GΩ (autoranging)
First effectivemeasuring ranges
0.1~50GΩ 0.2~100GΩ 0.2~100GΩ 0.4~200GΩ
accuracy ±5% rdgOther ranges accuracy ±10% rdg or 0.5% of scale lengthPower source R6P(AA)(1.5V) × 8Dimensions 200(L) × 140(W) × 80(D)mmWeight 1kg approx.Accessories 7165A(Line probe)(3m)
7224A(Earth cord)(1.5m)7225A(Guard cord)(1.5m)9158(Hard case)R6(AA) × 8Instruction manual
7165A(Line probe)(3m)7224A(Earth cord)(1.5m)7225A(Guard cord)(1.5m)8019(Hook type prod)9158(Hard case)R6(AA) x 8Instruction manual
Optional 8019(Hook type prod)8324(Adaptor for recorder)7253(Longer line probe with alligator clip)(15m)
8324(Adaptor for recorder)7253(Longer line probe with alligator clip)(15m)
3124 Test voltage 1k~10kV variable 1000VMeasuring ranges(automatic change)
1.6GΩ/100GΩ (autoranging)
100MΩ
First effectivemeasuring ranges
0.05~50GΩ 1~100MΩ
accuracy ±10% rdgOther ranges accuracy ±1% of scale lengthOutput voltage andset voltage indicate
DC 0~10kV±2%rdg±2dgt
Power source Ni-Cd rechargeable battery(1.2V) × 8Dimensions 200(L) × 140(W) × 80(D)mmWeight 1.5kg approx.Accessories 7082(Lead for recorder) 7083(Lead for battery charging)
7084(Earth and guard leads) 8075(Battery charger[120V]) or 8080(Battery charger[220V]) 9112(Carrying case[Hard])Ni-Cd rechargeable battery × 8 Instruction manual
3121A 3122A 3123A 31242500V test voltage
5000V test voltage
10000V test voltage
1k-10kV variable test voltage
Dual resistance scales
Recorder output
Guard terminal
HIG
H V
OLTA
GE IN
SULA
TION
TESTERS
34
• Ruggeddesignwithahardcarryingcaseforfielduse.
• DetachableHighVoltageLineprobe.
• Automaticranges,highandlowscales,indicatedbydifferentLEDs.
• Dripproof(IP41).
• Auto-dischargefunction.
• Permitsawiderangeofinsulationtestingupto100GΩatvariabletestvoltage from1kVto10kV.
• DCvoltageoutputforrecorders.
• Outputvoltageisshownonthedigitaldisplay.
• Aftertests,automaticallydischargesthechargesstoredinthecircuitundertest.
• OperatedbyrechargeableNickel-Cadmiumbatteries.
photo : 3123A
HIGH VOLTAGE INSULATION TESTER
Optional AccessoriesAccessory
HIGH VOLTAGE INSULATION TESTERS
www.kew-ltd.co.jp
MODEL 3125/KEW 3126
3125/3126Range Insulation resistance Voltage measurementTest voltage 500V 1000V 2500V 5000V —Measuring range 0.0~99.9MΩ
100~999MΩ0.0~99.9MΩ100~999MΩ1.00~1.99GΩ
0.0~99.9MΩ100~999MΩ1.00~9.99GΩ10.0~99.9GΩ
0.0~99.9MΩ100~999MΩ1.00~9.99GΩ10.0~99.9GΩ100~1000GΩ(1TΩ)
30~600VAC/DC(50/60Hz)
Accuracy ±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt ±5%rdg±3dgt±20%(100GΩ or more)
±2%rdg±3dgt
Short circuit current 1.3mA : 3125 5.0mA : 3126 —Rated test current 1mA~1.2mA at 0.5MΩ load 1mA~1.2mA at 1MΩ load 1mA~1.2mA at 2.5MΩ load 1mA~1.2mA at 5MΩ load —Open circuit voltage 500VDC+30%, -0% 1000VDC+20%, -0% 2500VDC+20%, -0% 5000VDC+20%, -0% —Maximum display 999 Counts(1000 counts only at 1000GΩ) 630 CountsCurrent consumption 1000mA approx. (During measurement) 110mA approx.Applicable standards IEC 61010-1 CAT.Ⅲ 600V Pollution degree 2, IEC 61010-031, IEC 61326Power supply DC12V : LR14 x 8 pcsDimensions 205(L) x 152(W) x 94(D)mm
Weight 1.8kg approx.Accessories 7165A(Line probe), 7224A(Earth cord), 7225A(Guard cord) , 8019(Hook type prod), 9159(Carrying case[Hard]) ,
LR14(Alkaline battery size C) x 8, Instruction manual, Calibration certificateOptional 7168A(Line probe with alligator clip), 7253(Longer line probe with alligator clip), 8302(Adaptor for recorder)
HIG
H V
OLT
AG
E IN
SULA
TIO
N T
ESTE
RS
35
• Short-CircuitCurrentupto5mAtoSpeeduptests.(KEW3126)
• Widerangemeasurementsfrom500Vto5000Vandupto1TΩ
• LargedigitaldisplaywithBarGraphindicationandLEDbacklight.
• PolarizationIndexmeasurement(PI)
• DielectricAbsorptionRatio(DAR).(KEW3126)
• Filter function reducesnoise interference forobtaningstablemeasurement.
(KEW3126)
• IndicationofOutputvoltageandDischargevoltage.
• AutopoweroffandBatteryIndicator.
• SafetystandardIEC61010-1CAT.Ⅲ600V
photo : 3125
photo : 3126
MODEL 7253Longer line probe with alligator clip:15m
MODEL 8302Adaptor for recorder (Output 1mV/1µA)Connector side : 200mmAlligator clip side : 1100mm
MODEL 7168ALine probe with alligator clip : 3000mm
MODEL 9159Carrying case[Hard]
DCAC V AUTO POWER
OFF
HIGH VOLTAGE INSULATION TESTER
HIGH VOLTAGE INSULATION TESTERS
KEW 3128
HIG
H V
OLTA
GE IN
SULA
TION
TESTERS
36
• TestVoltage12kV(max),Resistance35TΩ(max),Short-CircuitCurrent5mA
(max).
• Graphicrepresentationoftheinsulationresistanceandleakagecurrentver-
sustimeonlargedisplaywithbargraphandbacklight.
• PrintScreenFunctionenablestorecordupto32displayscreens.
• InternalMemorycanstoreabout43,000data(max).
• Automaticdischargeaftertestanddisplayofdischargevoltage.
• Fineadjustmentofvoltagesettingateachrangeisalsopossible.
• CanbeoperatedfrominternalrechargeablebatteryorfromACline.
• RobustdesignforfieldusewithIP64rating(withlidclosed).
Function
• InsulationResistance(IR)&Leakagecurrent.
• PolarizationIndex(PI).
• DielectricAbsorptionRatio(DAR).
• DielectricDischargeIndex(DD).
• StepVoltage(SV).
• Capacitanceoftheobjectundertest.
3128Insulation resistance
Test voltage 500V 1000V 2500V 5000V 10000V 12000VMax measurement value 500GΩ 1TΩ 2.5TΩ 5TΩ 35TΩ
Accuracy
400kΩ~50GΩ±5%rdg±3dgt
800kΩ~100GΩ±5%rdg±3dgt
2MΩ~250GΩ±5%rdg±3dgt
4MΩ~500GΩ±5%rdg±3dgt
8MΩ~1TΩ±5%rdg±3dgt
50G~500GΩ±20%rdg
100G~1TΩ±20%rdg
250G~2.5TΩ±20%rdg
500G~5TΩ±20%rdg
1T~10TΩ±20%rdg10T~35TΩValues are displayed, but accuracy isn’t guaranteed
Short circuit current Max 5.0mALoad resistor to output rated voltage
0.5MΩ or more 1MΩ or more 2.5MΩ or more 5MΩ or more 20MΩ or more 24MΩ or more
Output voltageRated voltage 500V 1000V 2500V 5000V 10000V 12000VMonitor accuracy ±10%±20VOutput accuracy 0~+20% 0~+10% 0~+10% 0~+10% -5~+5% -5~+5%
Selectable range50~600V(in steps of 5V)
610~1200V(in steps of 10V)
1225~3000V(in steps of 25V)
3050~6000V(in steps of 50V)
6100~10000V(in steps of 100V)
10100~12000V(in steps of 100V)
Voltage measurementMeasuring range DCV : ±30~±600V, ACV : 30~600V(50/60Hz)Accuracy ±2%rdg±3dgt
Current measurementMeasuring range 5.0nA~2.40mA(Depending on the insulation resistance)Accuracy ±5%rdg±5dgt
Capacitance measurementMeasuring range 5.0nF~50.0µF 5.0nF~1.0µF (Display range : 5.0nF~50.0μF)Accuracy ±5%rdg±5dgt
GeneralApplicable standards IEC 61010-1 CAT.Ⅳ 600V Pollution degree 2, IEC 61010-031, IEC 61326, IEC 60529(IP64): with the lid closed.
Power sourceRechargeable Lead storage battery (12 *Charging time : approx. 8 hours) / AC Power supply (100V~240V, 50/60Hz)※Continuous measuring time: approx. 4 hours a load of 100MΩ at the Insulation resistance 12000V Range.
Dimensions 330(L) × 410(W) × 180(D)mm *Instrument and Hard caseWeight 9kg approx. (including battery) *Instrument and Hard case
Accessories7170(Power cord), 7224A(Earth cord), 7225A(Guard cord), 7226A(Line probe), 7227A(Line probe with alligator clip), 8029(Extension prod), 8255( CAT.Ⅳ Standard prod), 8212-USB-W(USB adaptor with KEW Windows(Software)), Instruction manual, Calibration Certificate
Optional 7254(Longer line plobe with alligator clip)(15m)
CAT.Ⅳ600V
DCAC V AUTO POWER
OFFUSB
PI Measurement (Polarization Index)Thisdiagnostictestrecognisesthefactthat"good"insulationwillshowagrad-ually increasingof InsulationResistanceafter thetestvoltage isapplied.TheInsulationResistanceismeasuredattwodifferenttimes:normallyat1minand10min(othertimesettingsarepossible).Thentheinstrumentdivideslaterread-ingbytheearlierreading,obtainingtheresultsocalledthePolarizationIndex(PI).PI isdependentontheshapeof insulation, influencedbymoistureanditdoesnotneedtobetemperaturecorrected. PI 4.0 or more 4.0~2.0 2.0~1.0 1.0 or more
Criteria Best Good Warning Bad
SV Measurement (Step Voltage)Thisisatestbasedontheprinciplethatanidealinsulationwillproduceidenticalreadingsatallvoltages,whileaninsulationwhichisbeingoverstressed,willshowlowerinsulationvaluesathighervoltages.Duringthetest,theappliedvoltageincrementallystepsbyacertainvoltagetakingsuccessive5-timemeasurement.Degradationofin-sulationmaybedoubtwheninsulationresistancesbecomelowerathigherappliedvoltages.
DD Measurement (Dielectric Discharge)
Thismeasurementmethodisusuallyusedtodiagnosismulti-layer insulations,whichrequires the instrument tomeasure thedischargecurrentandcapaci-tanceofthemeasuredobject1minaftertheremovalofthetestvoltage.Thisisverygoodinsulationdiagnosistesttodeteriorationsandotherprobleminthemultipleinsulationtobeassessed.
*Thiscriteriaisaguideandcouldbeslightlychangedandbeadaptedtoparticularobjectsundertestbasedonpracticalexperienceoftheusers.
*Thismethodhasbeenestablishedtotesthighvoltagegenerators installedinelectricpowerplantsintheEuropecountries.
DD 2.0 or less 2.0~4.0 4.0~7.0 7.0 or moreCriteria Good Warning Poor Very Poor
Dielectric Discharge=
Current value 1 min after completing measurement (mA)
Voltage value when a measure-ment complete x Capacitance (F)
DAR Measurement (Dielectric Absorption Ratio)DARmeasurementisaTime/ResistancetestmethodsimilartothePolarizationIndex(PI),butDARtakestheratiooftheinsulationusuallymeasuredat1minuteand30secondsinsteadof10minutesand1minutetypicallyofthePI.DARandPImeasurementsareusefulbecausetheycanbeusedtoeliminatetheinfluenceoftemperature,humidityandleakagecurrentslikelytoinvalidatethe“absolute”insulationresistancemeasurement.
DAR 1.4 or less 1.25~1.0 1.0 or lessCriteria Best Good Bad
Dielectric Absorption Ratio
=
TIME2Insulation resistance value 30 sec or 1 min after starting measurement
TIME1Insulation resistance value 15 or 30 sec after starting measurement
Accessories
Measuring data can be transferred to a PC in real-time.IR Measurement PC screen
PI Measurement PC screen
SV Measurement PC screen
Graphic representation of the leakage current versus time on display
Optional Accessory
System requirements
OS: Windows®7(32/64bit)/Vista/XPDisplay: XGA (Resolution 1024 x 768 dots) or moreHard-disk: Space required 100Mbyte or moreOthers: With CD-ROM drive and USB port
* Windows® is a registered trademark of Microsoft in the United States.
"KEW Windows" Software for reportThestoreddatacanbetransferredtoPCviaMODEL8212-USB.
MODEL 7254Longer line probe with alligator clip : 15m
HIGH VOLTAGE INSULATION TESTERS
www.kew-ltd.co.jp
HIG
H V
OLT
AG
E IN
SULA
TIO
N T
ESTE
RS
37
Please refer to P49 for the specification of USB adaptor (Model 8212-USB).
USB adaptor with “KEW Windows (Software)”MODEL 8212-USB-W
Polarizationindex
=
TIME 2Insulation resistance value 3 -10 min.
after starting measurement
TIME 1Insulation resistance value 30 sec. - 1 min.
after starting measurement
Voltage V is applied to the object (Resistance Rx) measured from the voltage injection transformer CT1, and the current I corresponding to the earth resistance is flowed.The current I is detected with detection transformer CT2, and object (Resistance Rx) measured can be put out by the calculation. (refer to the right diagram)
Rx, is defined as earth resistance under test, and R1, R2…Rn are defined as earth resistance of other measuring objects.
These earth resistances, R1, R2,… Rn can be considered that they are connected in parallel.And They can be regarded as a combined resistance Rs. The Rs can be regarded small enough against Rx since a combined resistance consists of several resistances. Following is an equivalent circuit diagram of this circuit.
Rx
Rx
Rx
R1 Rn
Rx
CT1
CT2
Rs
Rx Rx RsR1 R2 Rn
I
Rs
Ri
=Σn
i=1
11
Rs
Ri
=Σn
i=1
11
Rx 〉〉
RsRxRIV= = +
RxIV=
V
The international standard IEC 60364-6 provides informa-tion regarding the measurement of the resistance of an earth electrode for TT, TN and IT systems. This measurement shall be made by the Volt-Amperometric method using two auxiliary earth electrodes.The instrument that covers this requirement is the Earth Tester.
EARTH TESTERS
EAR
TH TESTER
S
38
Be sure to check earthed side of a commercial power supply.
Indicated Value
Simplified Measurement (with Test lead M-7127A)
LL
Precise Measurement (with Test lead M-7095A)
Measuring the earth resistance of load Measuring the earth resistance of wall socket
Measurementofthesimplifiedearthresistance.(2-Polemethod)
[KEW 4300/MODEL 4102A/4105A]
[MODEL 4200/KEW 4202]MeasurementoftheearthresistancewithEarthClamp(Why earth measurements can be found by only clamping it?)
Measurementoftheearthelectroderesistance(3-Polemethod)
[MODEL 4102A/4105A]
Features (4102A/4105A)
Optional Accessories
MODEL 8200-03Cord reels[3 pcs]
MODEL 8032Auxiliary earth spikes
[2 spikes/1set]
MODEL 9091Carrying case for cord reels
MODEL 7100APrecision measurement cord set(7095A, 8032, 8200-03, 9091)
MODEL 7095ATest leads for earth resistance
EARTH TESTERS
www.kew-ltd.co.jp
MODEL 4102A
MODEL 4105A
4102A/4102A-HMeasurement ranges
Earth resistance : 0~12Ω /0~120Ω /0~1200Ω Earth voltage[50,60Hz] : 0~30V AC
Accuracy Earth resistance: ±3% of full scaleEarth voltage: ±3% of full scale
Overload protection Earth resistance : 276V AC for 10 secondsacross 2 of the 3 terminalsEarth voltage : 276V AC for 1 minute
Applicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2 IEC 61557-1,5IEC 61010-031 IEC 60529(IP54)
Power source R6P(AA)(1.5V) × 6Dimensions 105(L) × 158(W) × 70(D)mmWeight 600g approx.Accessories 7095A(Earth resistance test leads) × 1set(red-20m, yellow-10m,
green-5m) 8032(Auxiliary earth spikes[2 spikes/set]) × 1set7127A(Simplified measurement probe) × 1setR6P(AA) × 6, 9121(Shoulder strap), Instruction manualCarrying case : 9084(Carrying case[Soft]) : 9164(Carrying case[Hard])
Optional 7100A(Precision measurement cord set)
4105A/4105A-HMeasurement ranges
Earth resistance : 0~20Ω /0~200Ω /0~2000Ω Earth voltage[50,60Hz] : 0~200V AC
Accuracy Earth resistance : ±2%rdg±0.1(20Ω range)±2%rdg±3dgt(200/2000Ω range)Earth voltage : ±1%rdg±4dgt
Overload protection Earth resistance : 280V AC for 10 secondsacross 2 of the 3 terminalsEarth voltage : 300V AC for 1 minute
Applicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2 IEC 61557-1,5IEC 61010-031 IEC 60529(IP54)
Power source R6P(AA)(1.5V) × 6Dimensions 105(L) × 158(W) × 70(D)mmWeight 550g approx.Accessories 7095A(Earth resistance test leads) × 1set(red-20m, yellow-10m,
green-5m) 8032(Auxiliary earth spikes[2 spikes/set]) × 1set7127A(Simplified measurement probe) × 1setR6P(AA) × 6, 9121(Shoulder strap), Instruction manualCarrying case : 9084(Carrying case[Soft]) : 9165(Carrying case[Hard])
Optional 7100A(Precision measurement cord set)
EAR
TH T
ESTE
RS
• Inadditiontothefacility forprecisionmeasurement, test leadsforsimplifiedtwowiremeasuringsystemalsosuppliedasstandardaccessories.
(unitcanbehungfromtheneckforsimplifiedmeasurement)
• Thelatestcircuitdesignpermitstheinstrumenttooperatewiththeminimumofinfluencefromearthvoltageandearthresistanceofauxiliaryearthspikes.
• Dustanddripproof.(designedtoIEC529IP54)
• Earthresistancevaluecanbereaddirectlyfromthescale.
• DesignedtomeetIEC61010-1safetystandard.
• Capableofmeasuringearthvoltage.
• Smallandlightweight.Shockresistantnewcasematerial.
• 2mAmeasuringcurrentpermitsearthresistancetestswithouttrippingearthleakagecur-
rentbreakersinthecircuitundertest.
• LeadwireconnectiontoCandPterminalsandproperauxiliaryearthresistancecanbecheckedby“OK” lamp.LeadwireconnectiontoCandEterminals isgoodwhen“OK”lampisilluminated.(4102A)
39
MODEL 4102A Soft case model
MODEL 4102A-H Hard case model
Soft case model Hard case model
MODEL 4105A Soft case model
MODEL 4105A-H Hard case model
AUTO
SIMPLIFIED EARTH TESTER
EARTH TESTERS
KEW 4106
KEW 4300
EAR
TH TESTER
S
40
• Earthresistancemeasurementwithsixrangescoveringmeasurementsfrom0.001Ωto200kΩ.
• Earth resistivity (ρ)measurement isautomaticallycalculatedafterhavingset thedis-tancebetweenAuxiliaryEarthSpikes(Wennermethod).
• Automatic andManual selection of theTest Current Frequency in four bands of94/105/111/128Hz. InAutomaticmodeKEW4106will select themost suitableFre-quency.
• AdvancedFilteringmethod(basedonFFTFastFourierTransform)reducesnoise inter-ferenceforobtainingstablemeasurements.
• Up to800measurement resultscanbesaved in thememoryand recalledon thedis-play.
• ThestoredresultscanbetransferredtoaPCviaUSBadaptor(Model8212-USB)byus-ingsoftware“KEWReport”whichareincluded.
• RobustdesignwithIP54protection.
• 200/2000Ω(2ranges):auto-ranging.
• Warningbuzzertriggeredat100Ωorless.
• LEDlightsupwhenalargeearthvoltageisdetected.
• Livecircuitwarningwhen30Vorhighervoltageisdetected. (KEW4300detectsvoltageevenwhenmeasuringresistances.)
• LEDlightforilluminatingmeasurementpoints. (Itturnson/offautomaticallyinrelationtotheambientbrightness.)
• Smalltestcurrent(max2mA)nottriggeringRCD.
KEW4300 issimplifiedearth resistance tester (basedon2-polemethod) thatcanbeusedforvariousdistributionlinesandelectricalappliancesanditalsocanmea-sureAC/DCvoltage.(AsforACvoltages,truermsvaluescanbeobtained.)
4106Function Range Resolution Measuring range Accuracy
Earth resistanceRe(Rg at ρ measurement)
2Ω 0.001Ω 0.03~20.99Ω ±2%rdg.±0.03Ω20Ω 0.01Ω 0.03~20.99Ω
±2%rdg.±5dgt200Ω 0.1Ω 0.3~209.9Ω
2000Ω 1Ω 3~2099Ω20kΩ 10Ω 0.03~20.99Ω
200kΩ 100Ω 3~2099ΩAuxiliary earth resistance Rh, Rs
8% of Re+Rh+Rs
Earth resistivity ρ
2Ω
0.1Ω·m~1Ω·mAutoranging
0.2~395.6Ω·m
ρ=2×π×a×Rg
20Ω 0.2~3956Ω·m200Ω 20~39.56kΩ·m
2000Ω 0.2~395.6kΩ·m20kΩ
2.0~1999kΩ·m200kΩ
Series interference voltage Ust (A.C only)
50V 0.1V 0~50.9Vrms ±2%±2dgt
Frequency Fst Autoranging 0.1Hz, 1Hz 40Hz~500Hz ±1%±2dgtTest Current 80mA(max) Memory capacity 800 dataCommunication interface Model 8212-USB Optical AdaptorLCD Dot-matrix 192 × 64, monochromeOver-range indication “OL”Overload protection between E-S(P) and between E-H(C) terminals AC280V / 10 sec
Applicable standards IEC 61010-1 CAT.Ⅲ 300V, CAT.Ⅳ 150V Pollution degree 2IEC 61010-031, IEC 61557-1,5, IEC 61326-1(EMC), IEC 60529(IP54)
Power sourceDC12V : sizeAA manganese dry battery (R6P) x 8 (Auto power off: approx. 5 minutes)
Dimensions 167(L) × 185(W) × 89(D)mmWeight approx. 900g (including batteries)
Accessories
7229A(Earth resistance test leads), 7238A(Simplified measurement test leads)8032(Auxiliary earth spikes[2spikes/set])×2, 8200-04(Cord reels [4pcs]), 8212-USB(USB adaptor with “KEW Report(Software)”)9121(Shoulder strap), 9125(Carrying case)R6P×8, Instruction manual
Optional 8212-RS232C(RS232C adaptor with “KEW Report(Software)”)
4300Earth resistanceranges
200.0/2000Ω(Auto ranging)±3%rdg±5dgt
Voltage ranges AC:5.0~300.0V(45~65Hz) ±1%rdg±4dgtDC:±5.0~300.0V ±1%rdg±8dgt
Applicable standards IEC 61010-1 CAT.Ⅲ 300V pollution degree 2IEC 61010-031,61557-1,-5IEC 61326-1,2-2,IEC 60529(IP40)
Power source Size AA alkaline battery x 2 pcsDimensions 232(L) x 51(W) x 42(D)mmWeight 220g approx(including battery)Accessories 7248(Test lead with Alligator clip and Flat test probe)
8072(CAT.Ⅱ Standard prod)8253(CAT.Ⅳ Standard prod)8017(Extension prod long)9161(Carrying case)Instruction manual, LR6(AA)×2
AUTO POWEROFF
EARTH CLAMP TESTER4202
Accessories
MODEL 8304 MODEL 9167Resistor for operation check Carrying case[Hard]
Earth Clamp Line up
EARTH CLAMP TESTERS
www.kew-ltd.co.jp
MODEL 4200/KEW 4202 4200 4202Earth resistance Auto range
20.00/200.0/1200Ω*±1.5%±0.05Ω(0.00~20.99Ω)±2%±0.5Ω(16.0~99.9Ω)±3%±2Ω(100.0~209.9Ω)±5%±5Ω(160~399Ω)±10%±10Ω(400~599Ω)
AC current(50Hz/60Hz)Auto range
Values are displayed, but accuracy isn't guaranteed(600~1260Ω)100.0/1000mA/10.00/30.0A±2%±0.7mA(0.0~104.9mA)±2%(80mA~31.5A)
Operating indication Earth resistance function : Constant voltage injectionCurrent detection(Frequency : Approx.2400Hz)Dual Integration
AC current function : Successive approximationOver-range indication "OL"is displayed when input exceeds the upper limit of a measur-
ing rangeResponse time Approx. 7 seconds (Earth resistance)
Approx. 2 seconds (AC current)Sample rate Approx. 1 times per secondCommunicationInterface
—Bluetooth Ver2.1 + EDR Class2
Power source DC6V : R6P(sizeAA manganese battery) x 4 or LR6 (sizeAA alkaline battery) x 4
Current consumption Approx. 50mA (max.100mA) Approx. 50mA (max.100mA)Measurement time Approx.12 hours (when R6P is used)
Approx.24 hours (when LR6 is used)Approx.5 hours (when R6P is used) Approx.21 hours (when LR6 is used)
Auto power-off Turns power off about 10 minutes after the last button operation.Applicable standards IEC 61010-1 CAT.Ⅳ 300V Pollution degree2
IEC 61010-2-032, IEC 61326 (EMC)Conductor size Approx. φ32mmDimension 246(L)×120(W)×54(D)mmWeight Approx. 780g (including batteries)Accessories R6P x 4, Instruction manual
8304 (Resister for operation check) 9166 (Carrying case[Hard])
LR6 x 4, Instruction manual8304 (Resister for operation check)9167 (Carrying case[Hard])
•Crest factor ≦ 3 (50Hz/60Hz, peak value shall not exceed 60A)
*4 counts or less are corrected to 0.
4200 4202
Common functionsEarth resistance, AC current, Back light function, Data hold function, Auto power off, Memory function
Individual functions — Bluetooth communication
EAR
TH C
LAM
P T
ESTE
RS
photo : 4202
1Ω loop 10Ω loop
NEW
41
• Theearthresistancefrom0.05to1200Ωcanbemeasuredwithouttheauxiliaryearthspikesinmulti-earthingsystems
• TrueRMSleakageorphasecurrentreadingsfrom0.1mAto30.0Aprovidesvitaladdi-tionalinformationinearthingnetworks
• FilterfunctionoffersincreasedimmunitytoelectricalnoiseandaNoisemarkappearsinexcessivelyhighnoisyenvironments
• Memoryfunctionupto100data
• Bluetoothcommunication(4202only)
Note:Asingleearthingcannotbemeasured.(OnlyforMultipleEarthingsystem)
※Communication charges may be incurred separately to download application
DownloadKEW Smart 4202
Free Android software "KEW Smart 4202" is available on download site
Various useful functions are available on Android devices using Bluetooth communication(4202 only)
Comparator function informs when the mea-sured value is lower/higher than the preset value
Measured data with time and location info can be sent by E-mail
Recorded data can be transferred (up to 100 measurements)
Measurementresults
GPS data collection may be lost since the GPS signal differs depending on the location of satellites.To access GPS data and send emails, an Internet connection is required. Communication charges may be incurred separately for using these functions.
Beep! Beep!
※Available on the Android devices equipped with Bluetooth/ GPS/ Data communica-tion function Supporting Android ver. 2.2 - 4.0Max communication distance :10mExternal communication method : Bluetooth ver. 2.1+EDR Class 2Bluetooth is a registered trademark of the Bluetooth SIG, Inc.Android is a registered trademark of the Google Inc.
Bluetooth
Accessories
MODEL 7121B(Distribution board test leads)
MODEL 7123 (AU)Australian plug
MODEL 7124 (UK)British plug(13A)
MODEL 7125 (EU)European SHUKO plug
MODEL 7126 (SA)South African plug
Molded plug test leads
Loop Testing Methods
LOOP/PSC TESTERS
MODEL 4118A 4118ALoop impedance ranges 20/200/2000ΩLoop impedance accuracy ±2%rdg±4dgtAC test current 20Ω 25A
200Ω 2.3A2000Ω 15mA
AC test period 20Ω (20ms)200Ω (40ms)2000Ω (280ms)
PSC ranges 200A(2.3A 40ms)2000A(25A 20ms)20kA(25A 20ms)
PSC ranges accuracy Consider accuracy of loop impedanceVoltage 110V~260V ±2%rdg±4dgtOperating voltage 230V +10%, -15%(195V~253V)50HzApplicable standards IEC 61010-1 CAT.Ⅲ 300V IEC 61557-1,3
IEC 61010-031 Pollution degree 2 IEC 60529(IP54)Dimensions 185(L) × 167(W) × 89(D)mmWeight 750g approx.Accessories Molded plug test leads*
7121B(Distribution board test leads)9147(Cord case)9121(Shoulder strap)Instruction manual
* 7123(AU): Australian plug 7124(UK): British plug(13A) 7125(EU): European SHUKO plug 7126(SA): South African plugLO
OP/P
SC TESTER
S
42
• Custommicroprocessorcontrolledforhighestaccuracyandreliability.
• 3LEDsforcheckingcorrectwiringstatus.
• 15mALOOPmeasurement:LOOPimpedance2000Ω rangemeasurement iscarriedoutwithlowtestcurrent(15mA).ThecurrentwillnotcausetrippingoutinvolvedRCDeventheonewiththelowestnominaldifferentialcurrent(30mA).
• DirectreadingofProspectiveShortCircuitCurrent(PSC).
• Measurelowloopresistances(resolutionof0.01Ω)
• Automaticlock-outiftestresisteroverheats.
• Largecustomdigitaldisplayreadout.
• Visualindicationofreversedphaseandneutralwiringatsocket.
• DesignedtoIP54Rating
In the buildings mainly used for private residence where low voltage power is supplied from electric utilities the funda-mental protection against electric shock hazards is provided by appropriately coordinating the function of an earthing circuit with automatic switches placed at the latter stage of indoor wiring circuits. This is intended to quickly cut off the supply to an earthing circuit where a fault occurs following touch voltage exceeding an acceptable limit. Proper protection against electric shock hazards is given when the TT wiring system satisfies the requirement as expressed by the following formula:Ra × la ≤ 50where Ra is the sum of the resistances of earth bars and protective conductors and Ia is the maximum current of a pro-tection system provided for installations, indicating that the value obtained by multiplying Ra with Ia is not more than 50V. This means a maximum voltage one can touch shall not exceed 50V in the event of an earth fault.
Method of earth fault loop impedance testing at socket outlet. As shown in Fig.1, total earth fault loop impedance can be measured by plugging a loop tester into socket . The value of earth fault loop impedance measured represents the sum of transformer coil winding resistance, phase conductor (L3) resistance and protective conductor (PE) resistance as well as source earth resistance and installation earth resistance. With the loop tester set to any one of the PSC (prospective short circuit current) range, it is also possible to measure earth fault current.
Fig.1 Earth fault loop impedance testing at socket outlet.
Optional AccessoriesAccessories
Accessories
MODEL 7246MODEL 7247
MODEL 9156Soft case
MODEL 7187A (UK)British plug
Blue, Green, Red
Black, Green, Red
MODEL 7218A (EU)European SHUKO plug
MODEL 7221A (SA)South African plug
MODEL 7222A (AU)Australian plug
Main test lead
Distribution board test lead
LOOP/PSC TESTERS
www.kew-ltd.co.jp
KEW 4140
LOO
P/P
SC T
ESTE
RS
43
• Anti-TripTechnologyforcompletetripfreeLooptestingonallRCDsrated 30mAandabove.
• DualDisplayallowssimultaneousmeasurementslikeLoop&PFC/PSC.
• TwowireconnectionforLoopL-L,L-NandPSCtestingispossible.
• Phaserotation,VoltageandFrequencymeasurements.
• Lock-downtestbuttonfor'handsfree'testingwithauto-startoperation.
• DisplayandfrontpanelkeyboardswithBacklighttobevisibleindarkplaces.
• WaterandDustproof(IP54)
4140Loop Impedance
Function L-PE ATT OFF L-PE ATT ON L-N/L-L
Rated voltage 230V (50/60Hz)L-N: 230V (50/60Hz)L-L: 400V (50/60Hz)
Operating Voltage 100~280V (45~65Hz) 100~500V (45~65Hz)Range (Auto-Ranging) 20/200/2000Ω 20/200/2000Ω (L-N<20Ω) 20Ω
Nominal Test Current at 0Ω External Loop: Magnitude/Duration at 230V
20Ω:6A/40ms200Ω:2A/20ms2000Ω:15mA/500ms
L-N:6A/60msN-PE:10mA/approx. 5s
20Ω:6A/20ms
Accuracy ±3%rdg±4dgt (*1) ±3%rdg±6dgt (*1)L-N: ±3%rdg±4dgtL-L: ±3%rdg±8dgt
PFC(L-PE)/PSC(L-N/L-L) (*2)Function PSC PFC (ATT) PSC
Rated voltage 230V (50/60Hz)L-N: 230V (50/60Hz)L-L: 400V (50/60Hz)
Operating Voltage 100~280V(45~65Hz) 100~500V(45~65Hz)Range (Auto-Ranging) 2000A/20kA 2000A/20kA(L-N<20Ω) 2000A/20kA
Nominal Test Current at 0Ω External Loop: Magnitude/Duration at 230V
20Ω:6A/40ms200Ω:2A/20ms2000Ω:15mA/500ms
L-N:6A/60ms N-PE:10mA/approx. 5s
20Ω: 6A/20ms
Phase RotationOperating Voltage 50~500V, 45~65Hz
RemarksCorrect phase sequence : displayed “1.2.3” and markReversed phase sequence : displayed “3.2.1” and mark
VoltsFunction Volts FrequencyMeasuring range 0~500V 45~65HzAccuracy ±2%rdg±4dgt ±0.5%rdg±2dgt
Applicable standardsIEC 61010-1 CAT.Ⅲ300V (500V L to L) IEC 61010-031, IEC 61557-1,3,7,10, IEC 60529 (IP54), IEC 61326(EMC)
Power source 1.5V AA batteries × 6 *Use of alkaline batteries (LR6) is recommended.Dimensions 84(L) × 184(W) × 133(D)mmWeight 860g (including batteries.)
Accessories includedMain test lead (*3), Distribution board test lead (*4), 9155 (shoulder strap), 9156 (Soft case)LR6 (Battery) × 6, Instruction manual, Calibration certificate
*1: Accuracy of L-N LOOP displayed on the Sub Display is synchronized with the one at L-N/L-L function. *2: PSC/PFC Accuracy is derived from measured loop impedance specification and measured voltage specification.*3: 7187A:(UK)British plug, 7218A:(EU)European SHUKO plug, 7221A:(SA)South African plug, 7222A: (AU)Australian plug*4: 7246 : Blue, Green, Red, 7247 : Black, Green, Red
Accessories
MODEL 7121B(Distribution board test leads)
MODEL 7123 (AU)Australian plug
MODEL 7124 (UK)British plug(13A)
MODEL 7125 (EU)European SHUKO plug
MODEL 7126 (SA)South African plug
Molded plug test leads
RCD TESTERS
MODEL 5406A
MODEL 5402D 5402DRated tripping current 5/10/30/100/300/500mAFault condition settings × 1/2 × 1 Fast (250mA)Trip current duration 2000ms 40ms (Fast trip)Lowest resolution 1msTrip time accuracy ±2%rdg±3dgtOperating voltage 220/230/240V [50Hz/60Hz]Dimensions 140(L) × 90(W) × 20(D)mmWeight 350g approx.Accessories 7019(Test leads)
9045(Carrying case)Instruction manual
5406ARated tripping current 10/20/30/200/300/500mAFault condition settings × 1/2 × 1 × 5 × DC
Auto RampTrip current duration 1000ms 200ms(× 5)
Lowest resolution 1msTrip time accuracy ±0.6%rdg±4dgtOperating voltage 230V+10%-15%
(195V~253V)[50Hz]Applicable standards IEC 61557-1,6
IEC 61010-1 CAT.Ⅲ 300V IEC 61010-031 Pollution degree 2IEC 60529(IP54)
Dimensions 186(L) × 167(W) × 89(D)mmWeight 800g approx.Accessories Molded plug test leads* 9147(Cord case)
9121(Shoulder strap) Instruction manualOptional 7121B(Distribution board test leads)
* 7123(AU) : Australian plug 7124(UK) : British plug(13A) 7125(EU) : European SHUKO plug 7126(SA) : South African plug
RC
D TESTER
S
44
• Accuratedigitalreadoutoftrippingtime.
• Twoneonlampsgivequickcheckforcorrectwiring.
• Compact,lightweightandsimpletooperate.
• Zerocrosscircuitrypermitstestingat0and180degreeportionofsinewave. Atthesetwotestsminimum(best)andmaximum(worst)triptimeswillbedisplayed.
• Custommicroprocessorcontrolledforhighestaccuracyandreliability.
• 3LEDsforcheckingcorrectwiringstatus.
• 0and180degreephaseangleswitchpermitsquicktestsandconsistentreadings.
• Digitalread-outoftrippingtime.
• TestofalargekindofRCDs:Standard,Selective,ACandA(DCsensitivebreakers).
• Constantcurrentsourcecircuitryensuresthatafluctuatingmainsvoltagedoesnotaffecttheaccuracyofreadings.
• Largecustomdigitaldisplayreadout.
• Visualindicationofreversedphaseandneutralwiringatsocket.
• DesignedtoIP54Rating.
• ComplieswithIEC61557
Accessories
MODEL 7128ATest leads
Neutral - Line
400V
230V230V
230V400V
400VL1
L2
L3
RED BLACK
LOAD
LINENEUTRAL
POWER
N
400V
230V230V
230V400V
400VL1
L2
L3
RED BLACK
LOAD
L2 L1
POWER
N Connection using Earth
POWER
RED
LOAD
Test lead withalligator clip
Connect the“PRIMARY”of theConnectorBlocktotheNeutralofthepowerofRCD,andthe“SEC-ONDARY”oftheConnectorBlocktotheLineoftheloadofRCD.
Line - Line Connectthe“PRIMARY”oftheConnectorBlocktoL2ofthepowerofRCD,andthe“SECONDARY”oftheConnectorBlocktoL1oftheloadofRCD.
Earth - Line Connect the“PRIMARY”of theConnectorBlocktoEarth,andthe“SECONDARY”oftheConnectorBlocktoLineoftheloadofRCD.
RCD TESTERS
www.kew-ltd.co.jp
KEW 5410 5410Measurement of RCD trip time Measurement of trip out current
Range ×5 ×1 ×1/2 Auto Ramp (mA)Rated voltage 100V±10%
200V+32%/-10%400V±10%(50/60Hz)
Test current 15/30/50/100mA 15/30/50/100/200/500mA 15/30/50/100/200/500mAMeasuring range Testing time
200msTesting time2000ms
Testing time2000ms
40%~110% of IΔn(goes up by 5%)Testing time300ms x 15 steps
Accuracy Trip time ±1%rdg±3dgt ±1%rdg±3dgt ±1%rdg±3dgt Test current at each step-4%~+4%Test current +2%~+8%dgt +2%~+8%dgt -8%~-2%dgt
Voltage measurementMeasuring range 80V~450V(50/60Hz)Accuracy ±2%rdg±4dgt
Applicable standards
IEC 61010-1 Pollution degree 2 CAT.Ⅲ 300V/ CAT.Ⅱ 400VIEC 61010-031IEC 61557-1,6IEC 60529(IP54)
Display 1999 counts(3 1/2digits), Large LCDOperating temperature & humidity
0ºC ~ 40ºC, relative humidity 85%(no condensation)
Storage temperature & humidity
-20ºC ~ 60ºC, relative humidity 85%(no condensation)
Insulation resistance 50MΩ or more / 1000V(between electrical circuit and enclosure)Power source DC12V / Size AA battery R6P(SUM-3)×8pcsDimension 186(L)×167(W)×89(D)mmWeight Approx. 965g (including batteries)Accessories 7128A(Test leads) 7129A(Test lead with alligator clip)
8017(Extension prod)×2 9147(Cord case), 9121(Shoulder strap), Instruction manual, R6P(SUM-3)(AA)×8
*Only the RCD type G (without trip out time-delay) can be tested at Auto Ramp Test ; type S (time-delay) cannot be tested.
RC
D T
ESTE
RS
45
• Measurement of RCD trip time Conductingtestingofratedresidualnon-operatingcurrentsatx1/2Range,measuringRCDtriptimeatx1andx5Ranges.
• Measurement of trip out current Measuringtripoutcurrentbyvaryingcurrentautomatically.
• Remote Test EnablingausertoholdtheTestLeadswithhisbothhandsbylockingtheTestButton. Measurementwillautomaticallystartwhenthemainvoltageisdetected.
• Voltage Measurement Carryingoutaconstantmeasurementofvoltageinthestand-bymodeateachRange.
• Auto-detection of Contact voltage DetectingthevoltagetoearthofEarthelectrodesorProtectiveconductorsduringRCDtest-whenapplyingtestcurrents-atmeasurementusingEARTHinordertopreventelectricalshockscausedbythedamagedearth.MeasurementwillbeceasedatAC50Vormore.
• Dust- and Water-proof Dust-andWater-proofconstruction.(designedtoIEC60529IP54)
• Backlight Facilitatingworkingatdimlyilluminatedlocations.
MODEL 7129ATest lead with alligator clip
MODEL 8017Extension prod
The leakage current is recorded by 3ch input60,000 data is recorded
The leakage current clamp sensor can be connected up to three channels
•Continuous recording mode
•Event recording mode / The maximum value recording mode
•Capture recording mode *Accuracy of electric current adjudication is different. For details, refer to the operation manual
LEAK LOGGER
LOGGERS
MODEL 5001
5001Operation system Successive approximationInput AC voltage(AC 100mV/A)Maximum circuit voltage AC 170mVrms, 250mV peak valueNumber of input channel 3 ChannelsMeasurement method True RMSMeasurement interval 1,2,5,10,15,20,30 sec. / 1,2,5,10,15,20,30,60 min.Over range indication "OL" mark appears when exceeding measuring rangeWarning of voltage of battery Battery mark display of 4 stagesContinuous available time battery life About 40 days on the event record mode (Normal temp.) Dimensions 111(L) × 60(W) × 42(D)mmWeight About 315g (Include batteries)The maximum display 1049 countsApplicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution degree2 IEC 61326 (EMC)Power source Alkaline battery LR6 × 6Accessories Manual, Alkaline battery LR6, KEW LOG Soft 2 (PC software), 7148(USB cable), 9118(Carrying case[Soft])Optional 8141/8142/8143(Leakage current clamp sensor) 7185(Extension cable) 9135(Carrying case)
Range Measurement range Accuracy Accuracy of sensor combination100mA 0 to 100.0mA
±1.0%rdg±5dgt±2.0%rdg±10dgt
1000mA 0 to 1000mA ±2.0%rdg±6dgt
Range Measurement range Accuracy Accuracy of sensor combination100mA 0 to 100.0mA
±1.5%rdg±7dgt±2.5%rdg±12dgt
1000mA 0 to 1000mA ±2.5%rdg±8dgt
Range Measurement range Accuracy Accuracy of sensor combination100mA 0 to 100.0mA
±3.0%rdg±2%fs±4.0%rdg±2.5%fs
1000mA 0 to 1000mA ±4.0%rdg±2%fs
LOG
GER
S
46
60,000dataisrecordedwhen1chisusedandwhenthreeallchannelsareused,20,000dataisrecordedforeachchannel
Continuous measurement time•About40days
Data where it doesn’t disappear even if battery is consumedDatadoesn’tdisappearbyusingthenonvolatilememorywhenthebatteryisconsumedandthebatteryisex-changed.(warrantyfor10years)
Battery residual displayThebatterystateisdisplayedby4stages.(Whenblinkingindicatorisdisplayed,itispossibletomeasureforaboutoneday)
The present time, recording intervals, the start of recording, the recording method, the name of monitoring site and the comment can be set by using supplied software
Selection of one time mode and endless mode•Onetimeon Stoprecordingwhenthememoryisfilled.•Onetimeoff(endless)Overwritefromolddataandleavethelatestdata.
Recall function•Thelatest10datacanbechecked.•Therecalldatais Displaymonthanddate Displayhourandminute Displaycurrentvalue
Asfortheleakageclampsensor,anarbitrarycombinationispossibleIt can be attached to the metallic plate with magnet
The user friendly PC software “KEW LOG Soft 2” is supplied.
Software isEnhanced !
Easy to set up with a PC
System requirements
OS: Windows®7(32/64bit)/VistaDisplay: XGA (Resolution 1024 x 768 dots) or moreHard-disk: Space required 100Mbyte or moreOthers: With CD-ROM drive and USB port
* Windows® is a registered trademark of Microsoft in the United States.
•Thetypeofthesensorconnectedtothe loggerwillbe automatically recognized.
•Justclickappropriatedialogboxesforsetupifitisnotrequired to input any comments.
•ByusingcommerciallyavailableUSBhub,multipleloggers can be connected to a PC and can set the syn-chronized time.
Large data can be easily processed A graph can be made by just one click Capable of registering the names of 1,000 sites
Recorded data can be directly transferred to PC via USB cable
OptionalLeakage current type
MODEL 8141MODEL 9135
φ24mm AC1000mA
MODEL 8142 MODEL 8143φ40mm AC1000mA φ68mm AC1000mA
Clamp sensor Clamp sensor Clamp sensor
8datas(about 0.8 sec)interval
ofrecording
intervalof
measurement
start recoding
recordingvalue
stop recording
presetvalue
presetvalue50%
10 secondinterval
•To record the current change of a long term, and to measure and record at constant intervals, the state of leak that changes along with time is confirmed.
•The memory number is 60,000. ( 1ch only is used. )
•There are 15 kinds of settings at recording intervals from 1 second to 60 minutes.
1Continuous recording mode
•Frequency is confirmed at a momentary current value of the leak occurrence and time.
•The operation of ELCB is obtained by sam-pling for 1.6 milliseconds.
• When the current set t ing va lue is exceeded, eight data (a true effective value of about 0.8 seconds) and peak values are recorded before and behind that.
•LED blinks when the current setting value is exceeded.
2Event recording mode
•Easy finding of intermittent leak.•The operation of ELCB is obtained by sampling for 1.6 milliseconds.
•When exceeding set current value, it records the max. value every 10 seconds. The leak occurrence period of intermittent leak can be checked when the set current value becomes 50% or less, or 10 minutes will be recorded.
•LED blinks when the current setting value is exceeded.
3The maximum value recording mode
•The observation of the shape of waves is simply possible by sampling one millisec-ond.
•When the current setting value is exceeded, the instantaneous value of 200 milliseconds ( For 10 to 12 shape of waves ) is recorded before and behind that.
•LED blinks when the current setting value is exceeded.
4Capture recording mode
4 recording modes are available for insulation monitoring
Direct data transmission to PCby USB connection
Carrying case
LOGGERS
www.kew-ltd.co.jp
LOG
GER
S
47
Ø24 Ø40 Ø68MAX 1000mA
MAX 1000mA
MAX 1000mA
Normal Recording Mode Trigger Recording Mode Capture/ Power Quality Analysis Recording Mode
3 channel inputs for the simultaneous recording of Leakage Current, Load Current and Voltage
Power Quality analysis. (only on KEW 5020)(PowerQuality:Referencevoltage,Swell,Dip,ShortpowerInterruptions)
Large capacity for storing 60,000 data points60,000datapointscanberecordedwhen1chisused,andwhenallthethreechannelsareused,20,000datapointsperchannelcanberecorded.
Lowpass Filter will filter out the harmonics.(CutoffFrequency=Approx.160Hz)
LED flickers when the preset current / voltage value is exceeded.(AvailableforTrigger/CaptureRecording,PowerQualityAnalysismodes)
CALL : Confirmation of recorded data•Thefollowingcanbedisplayed:numberofrecordeddatapoints,(max+min+peak)valueforeachchannel
completewithtime/dateinformationintheNormalrecordingmode.(Detectedvalues(i.e.whenvaluesareoutsidepresetlimits)canbedisplayedinotherrecordingmodes)
•RECALL:Thelast10recordeddatapointsincludingtime/datecanberecalledontheloggerdisplay.
Selection of One-time mode or Endless modeOne-time on : Recordingwillstopwhenmemoryisusedup.
One-time off : Overwritetheolddata,andstorethelatestdata.
Non Volatile MemoryRecordeddatawillberetainedevenifthebatteriesareexhaustedorreplacedduetothepresenceofanonvolatilememory(guaranteedfor10years)
Battery power indicatorIndicatesbatteryvoltagein4-levels.(It ispossibletousetheloggerforafurtherapprox24hoursevenafterthewarningsymbolisflashing.)
(AC50/60Hz,Sinewave,Input:10%ormoreoftherangeatCH1) (AC50/60Hzsinewave)
The user friendly PC software ” KEW LOG Soft ”is supplied.•Suppliedwiththeuserfriendlysoftware”KEWLOGSoft2”.•Thispermitsediting,analysisandgraphicaldisplayofdata.•TherecordeddataisdownloadableontoaPCviaUSBcable.•Variationofthemeasuredvoltageandcurrentdatacanbeconfirmedsimultaneously
onthePCdisplaymonitor.(onlyonKEW5020)•SimplifiedPowerIntegration (The“KEWLOGSoft2”usescurrentandvoltagerecordedtocalculatetheintegral
powerconsumption)•Continuousmeasuringtime:Approx.10days(AlkalineBattery)
LOGGERS
KEW 5010/5020
5010 5020Recording mode Normal, Trigger, Capture Normal, Trigger, Capture, Power quality analysisOperating system Successive approximation(CH1 single synchronized sampling)Rated max. working voltage AC9.9Vrms, 14V peak valueNumber of input channel 3chMeasuring method True RMSRMS measuring interval approx. 100ms.Sampling interval : Normal / Trigger mode approx. 1.65ms/CH
: Capture mode approx. 0.55ms (waveform: at every 1.1ms): P.Q.A mode — approx. 0.55ms
Low battery warning Battery mark display (in 4 levels)Over-range indication "OL" mark is displayed when exceeding the measuring rangeAuto power off Power-off function operates automatically after a switch remains for 3min. (when recording is stopped)Location for use Indoor use, Altitude up to 2000mOperating temperature & humidity range -10°C~50°C / Relative humidity 85% or less (no condensation)Battery DC6V : Alkaline battery(LR6) × 4pcs / External supply DC9V(Special AC Adaptor)Possible measurement time Approx.10days (with alkaline LR6 batteries)Applicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution degree2 IEC 61326 (EMC)Dimensions 111(L) × 60(W) × 42(D)mmWeight Approx. 265gAccessories Alkaline battery LR6×4 9118(Carrying case[Soft]) KEW LOG Soft 2(PC software) 7148(USB cable)
Instruction manual Quick manual Install manual USB Notice sheetOptional 8146/8147/8148(Leakage & Load current clamp sensor) 8121/8122/8123(Load current clamp sensor) 8129(Flexible clamp sensor)
8309(Voltage sensor : only KEW5020) 8320(AC adaptor) 9135(Carrying case) 7185(Extension cable)
Range RMS Accuracy100.0mA ±2.0%rdg±0.9%f.s. + Accuracy of sensorOther ranges ±1.5%rdg±0.7%f.s. + Accuracy of sensorCrest factor 2.5 or less :RMS accuracy(sine)+ 2%rdg+1%f.s.
*Max, Min and Instant Peak values in Normal Recording mode are just reference values; their accuracies aren't guaranteed.
Range Accuracy100.0mA ±3.5%rdg±2.2%f.s. + Accuracy of sensorOther ranges ±3.0%rdg±2.0%f.s. + Accuracy of sensor
Range Accuracy100.0mA ±3.0%rdg±1.7%f.s. + Accuracy of sensorOther ranges ±2.5%rdg±1.5%f.s. + Accuracy of sensor
LOG
GER
S
48
•Detects the referencevolt-age, Swell, Dip and Shor tInterruption.Recordstheval-uesdetectedwith thestarttimeandendtime.
•Samples the inputs every0.55msanddetectsthevolt-agefluctuationevery10ms.
•LEDflickerswhenthevoltagefluctuationisdetected.
4 recording modes make various measurements possible
Dip
Swell
ShortInterruption
SystemPower
Start End
•Records thevariationof thecurrent / voltage inagiveninterval (Formonitoring thevariationofthecurrent/volt-ageagainsttime.)
•Achoiceof15recordinginter-valsareavailable:1sec.to60min.
(1,2,5,10,15,20,30sec,1,2,5,10,15,20,30,60min.)
•Theaverageof themeasuredvalue inevery recording interval isrecorded.TheMax.,Min.andPeakvalues(sampledcrestvaluecon-vertedtosineRMSvalue)arerecordedevery10readings.
Normal recording mode
Capture recording mode
Trigger recording mode
Power Quality Analysis Mode
Formonitoringpowerlinestatusoranintermittentleakage. For observing an irregular operation of an ELCB/RCD, an irregularcurrent/voltage.
Forobservingwaveformseasily. Formonitoringandobservingvoltagefluctuations.
•Detects thevalue, timeandf requency of the current/ voltagewhen the presetvalueisexceeded.
•Whenthedetectionlevel(i.e.presetvalue) isexceeded,8datapoints(TrueRMSvaluesforapprox.0.8sec)andpeakvaluearerecordedbeforeandafterthepresetvalueisexceeded.
•Inrushcurrentoranabnormalcurrent/voltagecanbedetectedbysamplingtheinputsatevery1.6ms.
•LEDflickerswhenthemeasuredvaluesexceedthepresetcurrent/voltagevalue.
•Waveformdisplay via a PCbysamplingtheinputsevery0.55ms.
•When the preset current /voltage value is exceeded,instantaneous values arerecorded for 200ms (from10(50Hz) to12 (60Hz)waveforms)beforeandafterpresetvalue isexceeded.
•LEDflickerswhenthemeasuredvaluesexceedthepresetcurrent/voltagevalue.
8 data(for approx. 0.8sec)
Analyzing and processing the recorded data with a PCTheuserfriendlyPCsoftware“KEWLOGSoft2”issupplied.
Software isEnhanced !
(Normal and Trigger recording modes can be set up through the logger itself.)
Easy to set up with a PC
System requirements
OS: Windows® 7(32/64bit) /Vista/XPDisplay: XGA(Resolution 1024 x 768 dots) or more
Hard-disk: Space required 100Mbyte or moreOthers: With CD-ROM drive and USB port * Windows® is a registered trademark of Microsoft in the United States.
•Thetypeofthesensorconnectedtotheloggerwillbeautomaticallyrecognized.
•Justclickappropriatedialogboxesforsetupifitisnotrequiredtoinputanycomments.
•ByusingcommerciallyavailableUSBhub,multipleloggerscanbeconnectedtoaPCandcansetthesynchronizedtime.
Large data can be easily processed
A graph can be made by just one click Display of Power Quality Capable of registering the names of 1,000 sites
LOGGERS
www.kew-ltd.co.jp
LOG
GER
S
49
Optional AccessoriesMODEL 7133B Distribution board
test leadsMODEL 8212-RS232C
USB adaptor with “KEW Report (Software)”
Specifications
"KEW Report" Software for report
“KEWReport”transfersmeasurementdatafromtheKEW6010BtoaPCviaMODEL8212-USBorMODEL8212-RS232C.
MODEL 8212-USB
Accessories
MODEL 7122BTest leads KAMP10 Test lead with IEC connector
UKAU SAEU
MULTI FUNCTION TESTERS
KEW 6010B 6010BContinuity testing
Measuring range 20/200Ω (Auto-ranging)Open circuit voltage >6VShort circuit current >200mAAccuracy ±(3%rdg+3dgt)
Insulation resistance testingMeasuring range 20/200MΩ(Auto-ranging)Test voltage 500/1000VOpen circuit voltage +20%, -0%Rated current >1mAAccuracy ±(3%rdg+3dgt)
LOOP Impedance testingImpedance range 20Ω/2000ΩRated voltage 230V +10%, -15% [50Hz]Normal test current 20Ω: 25A/10ms
2000Ω: 15mA/350ms max.Accuracy ±(3%rdg+8dgt)
RCD testingTest current(Test current duration)
×1/2, ×1 10, 30, 100, 300, 500mA (2000ms)FAST 150mA(50ms)DC 10,30,100,300mA (2000ms), 500mA(200ms)Auto ramp Goes up by 10% from 20% to 110% of IΔn. 300ms × 10
Rated voltage 230V+10%, -15% 50HzAccuracy Test current × 1/2 : -8%, -2% × 1, Fast : +2%, +8%
DC : ±10% Auto ramp: ±4% Trip time ±(1%rdg+3dgt)
Uc testingMeasuring range 100VRated voltage 230V +10%, -15% [50Hz]Test current 5mA at IΔn=10mA
15mA at IΔn=30/100mA150mA at IΔn=300/500mA
Accuracy +5%, +15%rdg ±8dgtGeneral
Applicable standards EC 61010-1 CAT.Ⅲ 300V Pollution degree 2IEC 61557-1,2,3,4,6,10, IEC 60529 (IP40)
Power source R6 or LR6 × 8Dimensions 175(L) × 115(W) × 86(D) mmWeight 840g approx.Accessories 7122B (Test leads) KAMP10 (Test lead with IEC connector)*
9092 (Cord case) 9148 (Shoulder strap) Shoulder padInstruction manual R6P(AA)× 8
Optional 7133B (Distribution board test leads)8212-RS232C (RS232C adaptor with "KEW Report (Software)")8212-USB (USB adaptor with "KEW Report (Software)")
* KAMP10(EU):European SHUKO plug KAMP10(UK):British plug(13A) KAMP10 (AU):Australian plug KAMP10(SA):South African plug
MODEL 8212-USB MODEL 8212-RS232CCommunication method USB Ver1.1 -Driver type Virtual COM port -Communication speed 19200bps max. 9600bps max.
DimensionsAdaptor : 53(L)×36(W)×19(D)mmCable : 2m approx.
Adaptor : 61(L)×36(W)×19(D)mmCable : 1.6m approx.
Operating temperature and humidity -10~+50°C 85%RH or less with no condensation 0~+40°C 85%RH or less with no condensationStorage temperature and humidity -20~+60°C 85%RH or less with no condensation
MU
LTI FUN
CTIO
N TESTER
S
50
• DesignedtoIEC61010-1,IEC61557
• DataMemory:300measuredresults
• DownloadResultstoPCbyUsing8212DataCommunicationAdaptorthroughOpticalRS-232CPort.
RS232C adaptor with “KEW Report (Software)”
System RequirementsOS: Windows®7(32/64bit)/VistaDisplay: XGA(Resolution1024x768dots)ormore
Hard-disk: Spacerequired20MbyteormoreOthers: WithCD-ROMdriveandUSBport
*Windows® is a registered trade mark of Microsoft in the United States.
5 in 1
20/200Ω 500/1000V
20/2000Ω 10/30/100/300/500mA
100V
Continuity Insulation
Loop RCD
Uc
Optional Accessory
MODEL 7133B (OMA DIEC)Distribution board test leads
Accessories
MODEL 7132A (KSLP5)
MODEL 7122B
Test lead with IEC connector KAMP 10
Test leads
External earth probe (6011A only)
Plug
UKAU
SAEU
MULTI FUNCTION TESTERS
www.kew-ltd.co.jp
MODEL 6010A/6011A
6010A 6011AContinuity testing
Measuring ranges 20/200Ω(Autoranging) 20/200/2000Ω(Autoranging)Open circuit voltage >4V >6VShort circuit current >200mA DCAccuracy ±(3%rdg+3dgt) ±(1.5%rdg+3dgt)
Insulation testingMeasuring ranges 20/200MΩ(Autoranging)Test voltage 500V DC 250/500/1000V DCOutput voltage onopen circuit
570V±6% 250V+40%, -0%500+30%, -0% 1000V+20%, -0%
Rated current > 1mAAccuracy ±(3%rdg+3dgt) ±(1.5%rdg+3dgt)
Loop impedance testingRated voltage 230V AC +10%, -15%[50Hz]Voltage measuring range 100~250V AC[50Hz]Impedance ranges 20/2000Ω 20/200/2000ΩNominal test current 25A(20Ω range) 15mA(2000Ω range) 25A(20Ω range) 15mA(200Ω range) 15mA(2000Ω range)Accuracy 20Ω range ±(3%rdg+8dgt)
2000Ω range ±(3%rdg+8dgt)20Ω range ±(3%rdg+4dgt) 200Ω range ±(3%rdg+8dgt) 2000Ω range ±(3%rdg+4dgt)
PSC testingRated voltage – 230V AC +10%, -15%[50Hz]PSC ranges
–200A(15mA Test current) 2000A(25A Test current)20kA(25A Test current)
Accuracy–
PSC accuracy derived from measured loop impedance specification and measured voltage specification
RCD testingRated voltage 230V AC +10%, -15%[50Hz]Trip current settings RCD x 1/2 : 5,15,50,150,250mA
RCD x 1 : 10,30,100,300,500mAFAST : 150mA
RCD x 1/2 :10,30,100,300,500,1000mARCD x 1 : 10,30,100,300,500,1000mARCD x 5 : 10,30,100,300mA (on x 5 range max current 1A)
Trip current duration RCD x 1/2 x 1 : 2000ms RCD fast : 50ms RCD x 1/2 x 1 : 2000ms RCD fast : 50msAccuracy Trip current +3% of test current at 230V
Trip time ±(3%rdg + 3dgt)Trip current +10% -0% of test current at 230VTrip time ±(1%rdg + 3dgt)
GeneralApplicable standards IEC 61010-1 CAT.Ⅲ 300V pollution degree 2
IEC 61010-031 IEC 61557 IEC 61010-1 CAT.Ⅲ 300V pollution degree 2IEC 61010-031 IEC 61557 IEC60529(IP54)
Power source R6P or LR6 x 8Dimensions 115(L) x 175(W) x 86(D)mm 130(L) x 183(W) x 100(D)mmWeight 780g approx. 1100g approx.Accessories KAMP10(Test lead with IEC connector)*
7122B(Test leads), 9092(Cord case), 9148(Shoulder strap), Shoulder pad, P6P(AA) x 8, Instruction manual
KAMP10(Test lead with IEC connector)*7122B(Test leads), 7132A(KSLP5)(External earth probe) 9092(Cord case), 9121(Shoulder strap) P6P(AA) x 8, Instruction manual
Optional 7133B(Distribution board test leads)
※ KAMP10(EU):European SHUKO plug KAMP10(UK):British plug(13A) KAMP10(AU):Australian plug KAMP10(UK):South African plug
MU
LTI F
UN
CTI
ON
TES
TER
S
51
photo : 6010A photo :6011A5 in 14 in 1
20/200Ω 500V
20/2000Ω 10/30/100/300/500mA
Continuity Insulation
Loop RCD
20/200/2000Ω 250/500/1000V
20/200/2000Ω 10/30/100/300/500/1000mA
200/2000/20kA
Continuity Insulation
Loop RCD
PSC
Slim remote probe with test button as well as a lockdown option on the instrument for the most convenient hands free testing.
A single rotary dial to make your selection.
The instrument features a test button in the probe and a lockdown test but-ton for ‘hands free’ operation.
Auto test enables complete test ing of RCD (6 tests ) while the operator simply stands by and resets the RCD. All the results are displayed on one screen – no need to scroll.
MULTI FUNCTION TESTERS
KEW 6016
MU
LTI FUN
CTIO
N TESTER
S
52
Continuity MeasurementContinuous testingcanbecarriedoutbyuseof the testbutton lockdownfeature.Aselectablebuzzergives instantaneous indicationofcontinuity.Nullfacilityeliminatesthetest leadresistancefromtheresults,thenulledvalueisretainedeveniftheinstrumentisswitchedoff.LivecircuitwarningsaregivenbyaflashingLED,buzzerandindicationonthedisplay.
Insulation MeasurementThreeselectabletestvoltages250V,500Vand1000V.Anauto-dischargefunc-tionensuresthatcircuitsarenothazardousaftertesting.AredLEDgiveswarn-ingofhighvoltageoutputduringtestinganddischargingofthecircuit.Incaseofconnectingtoa livecircuit,a livecircuitwarning isgivenbyflashingLED,buzzerandindicationonthedisplay.
Loop Impedance MeasurementApatented(ATT)lowcurrentloopimpedancetestenableshighaccuracyloopmeasurements(upto0.01ohm)andquicktestingwithouttrippingRCDs.Ahighcurrentalternativeisselectableforevenhigheraccuracyandinstantaneousresults.Thesubsequenttestwilldefaulttothelowcurrenttest,thissavesanyinadvertenttrip-pingoftheRCD.TheKEW6016allowsalsoforphasetophaselooptests.
PSC / PFC MeasurementTheProspectiveShortCircuitCurrent(PSC)andProspectiveFaultCurrent(PFC)areautomaticallycalculatedandshownonthedisplay.Aslooptesting,thefunctionhaslowandhightestcurrentoptionswiththedefaulttolowcurrenttoavoidinadvertenttrippingofRCDs.
RCD MeasurementTheKEW6016hasacomprehensiveRCDtestfeatureforRCDtypeAC(AlternativeCurrents),RCDtypeA(PulsatingDirectCurrents),GeneralandSelective(delayed).Measuresat1⁄2x,1x,5xofnominalRCDcurrent.ItalsohasRampTestandAutotestwhereallresultsareshownononescreen.Touchvoltagelimitcanbeselectedfor25Vor50Vdependingonapplication.
Earth MeasurementUsingtheclassicalVolt-Amperemethodwithtwoauxiliaryearthspikesandwithoutexternalpowersource.Alltestleadsandspikesaresuppliedasstandardaccessories.
Phase rotationKEW6016cancheckthephaserotationofthreephaselineswithclearindicationofthesequenceonthedisplay.
Voltage MeasurementInaddictiontothevoltagemeasurement,thisfunctiongivesalsotheFrequencyofthevoltageundertest.
Memory FunctionSaveanddisplayupto1000data.
Hands Free Testing RCD (ELCB)-Auto Test
10 in 1
20/200/2000Ω 20/200/2000Ω250/500V
2000A/20kA 10/30/100/300/500/1000mA2000A/20kA
20/200/2000Ω 500V
Continuity LoopInsulation
PSC RCDPFC
Earth
Phase rotation
ACV
Frequency
Optional Accessories
MODEL 8212-RS232CUSB adaptor with “KEW Report (Software)”MODEL 8212-USB RS232C adaptor with “KEW Report (Software)”
Accessories
MODEL 7188ADistribution board fused test leads
MODEL 7196ATest leads with remote control switch
MODEL 7228AEarth resistance test leads
MODEL 8032Auxiliary earth spikes
[2 spikes/set]
MODEL 9142CarryingCase
"KEW Report" Software for report“KEWReport”transfersmeasurementdatafromtheKEW6016toaPCviaMODEL8212-USBorMODEL8212-RS232C.
Plug
7222A
7218A
7187A
7221A
Main test lead
MULTI FUNCTION TESTERS
www.kew-ltd.co.jp
RCD
Trip current Duration
X1/2: 2000msX1: G:550ms / S: 1000msX5: 410ms
Ramp: Goes up by 10% from 20% to 110%G:300ms/S:500msX10 times
Rated voltage
X1/2, X1, X5, Ramp, Uc: 230V+10%-15% 50/60Hz
Auto:
Depending on the accuracy at each function. Measurement sequence: X1/2 0°→X1/2 180°→X1 0°→X1 180°→X5 0°→X5 180° Measurements with x5 are not carried out for RCDs with nominal current of 100mA or more.
Accuracy Trip currentAC Type X1/2: -8%~-2%, X1, X5: +2%~+8%, Ramp: ±4%
A Type X1/2: -10%~0%, X1, X5: 0%~+10%, Ramp: ±10%Uc: +5%~+15%rdg±8dgt
EarthRange 20/200/2000Ω Auto-Ranging
Accuracy 20Ω: ±3%rdg+0.1Ω200/2000Ω: ±3%rdg+3dgt (Auxiliary earth resistance 100±5%)
Phase RotationRated Voltage 50-500V 50/60Hz
Remarks Correct phase sequence: are displayed “1.2.3” and markReversed phase sequence: are displayed “3.2.1” and mark
VoltsFunction Volts FrequencyRated voltage 25~500V, 45~65HzMeasuring range 25~500V 45~65HzAccuracy ±2%rdg+4dgt ±0.5%rdg+2dgt
General
Applicable standardsIEC 61010-1 CAT.Ⅲ 300V(500V L to L) Pollution degree 2IEC 61010-031, IEC 61557-1,2,3,4,5,6,7,10IEC 60529(IP40), IEC 61326(EMC)
Power source LR6 × 8Dimensions 136(L) × 235(W) × 114(D)mmWeight 1350g (including batteries.)
Accessories
Main test lead*4 7196A(Test leads with remote control switch)7188A(Distribution board fused test leads)7228A(Earth resistance test leads) 8032(Auxiliary earth spikes[2 spikes/set]) 8212-USB(USB adaptor with KEW Report(Software))9014(Cord case), 9142(Carrying Case), 9121(Shoulder strap), Buckle, Battery, Instruction manual
Optional 8212-RS232C(RS232C adaptor with KEW Report(Software))
ContinuityRange 20/200/2000Ω (Auto-ranging)Open circuit voltage (DC) 5V±20%(*1)
Short circuit current >200mA
Accuracy ±0.1Ω (0~0.19Ω )±2%rdg+8dgt (0.2~2000Ω)
Insulation resistanceRange 20/200/2000MΩ (Auto-ranging)
Open circuit voltage (DC) 20/200MΩ 250V+25% -0%20/200/2000MΩ 500V+25% -0%, 1000V+20% -0%
Rated current 20/200MΩ 1mA or > @ 250kΩ20/200/2000MΩ 1mA or > @ 500kΩ, @ 1MΩ
Accuracy20/200MΩ ±2%rdg+6dgt (0~19.99MΩ)
±5%rdg+6dgt (20~200MΩ)
20/200/2000MΩ ±2%rdg+6dgt (0~199.9MΩ)±5%rdg+6dgt (200~2000MΩ)
Loop impedanceFunction L-PE, L-PE (ATT), L-N / L-L
Rated voltageL-PE, L-PE (ATT): 100~260V (50/60Hz)L-N: 100~300V (50/60Hz)L-L: 300~500V (50/60Hz)
Nominal test current at 0Ω external loop: Magnitude/Duration at 230V
20Ω: 6A/20ms200Ω: 2A/20ms2000Ω: 15mA/500msL-N: 6A/60msN-PE: 10mA/approx. 5s
Range 20/200/2000Ω Auto-Ranging (L-N < 20Ω)
Accuracy L-PE, L-N / L-L: ±3%rdg+4dgt*2 ±3%rdg+8dgt*3
L-PE (ATT): ±3%rdg+6dgt*2 ±3%rdg+8dgt*3
PSC (L-N/L-L) / PFC (L-PE)Function PSC, PFC, PFC (ATT)
Rated voltage PSC: 100~500V 50/60HzPFC, PFC (ATT): 100~260V 50/60Hz
Nominal test current at 0Ω external loop: Magnitude/Duration at 230V
PSC: 6A/20msPFC: 6A/20ms, 2A/20ms, 15mA/500msPFC (ATT): L-N: 6A/60ms, N-PE: 10mA/approx. 5s
Range 2000A/20kA Auto-Ranging
AccuracyPSC/PFC accuracy is derived from measured loop impedance specification and measured voltage specification
RCDFunction X1/2, X1, X5, Ramp, Auto,Uc
Trip current settingX1/2, X1,Uc: 10/30/100/300/500/1000mAX5: 10/30/100mARamp: 10/30/100/300/500mA
6016
MU
LTI F
UN
CTI
ON
TES
TER
S
53
System requirements
OS: Windows®7(32/64bit)/Vista/XPDisplay: XGA (Resolution 1024 x 768 dots) or moreHard-disk: Space required 20Mbyte or moreOthers: With CD-ROM drive and USB port* Windows® is a registered trademark of Microsoft in the United States.
*1: Voltages are output when measurement resistance is under 2100 ohm.*2: 230V+10%-15%*3: Other voltages except for *2 *4: 7187A:British plug, 7218A:(EU)European SHUKO plug, 7221A(SA) South African plug, 7222A:(AU)Australian plug
"KEW Report" Software for report“KEWReport”transfersmeasurementdatafromtheKEW6050toaPCviaMODEL8212-USBorMODEL8212-RS232C.
MULTI FUNCTION TESTERS
MODEL 6018
MODEL 6050(LOOP+RCD)
6018Insulation testing
Test voltage 250V/50MΩ500V/100MΩ1000V/2000MΩ
Accuracy ±5%rdgEarth resistance
Simplified precision measurement
12Ω/120Ω/1200Ω
Accuracy ±3% of full scale valueAC voltage
0~600V AC ±3% of full scale valueEarth voltage
0~60V AC ±3% of full scale valueGeneral
Applicable standards IEC 61010-1 CAT.Ⅲ 600V pollution degree 2IEC 61010-031 IEC 61557
Power source R6P(AA)× 8Dimensions 130(L) × 183(W) × 100(D)mmWeight 1000g approx.(including batteries)Accessories 7103A(Test leads with remote control switch)
7161A(Flat test prod)7131B(Safety crocodile clips [black])8017(Extension prod)9092(Cord case)9121(Shoulder strap) R6P(AA)× 8Instruction manual
Optional 7100A(Precision measurement cord set)8016(Hook type prod)
6050(LOOP+RCD)Loop impedance ranges 20/200/2000ΩLoop impedance rangeswithout tripping RCDs
200 and 2000Ω with 15mA of test current
Max test current on loop ranges 3A (20Ω) / 15mA (200 and 2000Ω)PSC / earth fault current ranges 200/2000A/20kARCD test AC type(Standard and selective)
× 1/2× 1× 5Auto Ramp
10, 30, 100, 300, 500, 1000mA10, 30, 100, 300, 500, 1000mA10, 30, 100mA10, 30, 100, 300, 500mA
RCD test A type(Standard and selective)
10, 30, 100, 300, 500mA
RCD test currents multipliers × 1/2 × 1 × 5(max 1000mA type AC), (max 500mA type A)
RCD test time duration 1000ms: × 1/2 × 1 DC200ms: × 5 DC (500mA) and × 1(1000mA)
RCD ramp test From 20% to 110% of IΔn (AC type)Contact voltage block (RCD) 50V and 25VContact voltage reading (RCD) 100.0VPhase and earth(2 wires only) measurements
RCD (without DC)LOOP
Working voltage for loop tests 20Ω : 230V+10%, -15%200/2000Ω : 230V+10%, -15% and 400V+10%, -15%
Working voltage for RCD tests 230V+10%, -15%Voltage test 100~260V
(LOOP 200/2000Ω, PSC 200A:100~440V)Memory 300 memory locationsPC software, connection cable Optional with MODEL 8212Applicable standards IEC 61010-1 CAT.Ⅲ 300V IEC 61557
IEC 61010-031, IEC 60529(IP54) Power source R6P(1.5V)(AA)×8Dimensions 186(L) × 167(W) × 89(D)mmWeight 980g approx.(including batteries)Accessories Molded plug test lead*
9147(Cord case)Instruction manual 9121(Shoulder strap) R6P×8
Optional 7121B(Distribution board test leads)8212-RS232C (RS232C adaptor with "KEW Report (Software)")8212-USB (USB adaptor with "KEW Report (Software)")
* 7123:(AU)Australian plug 7124:(UK)British plug(13A) 7125:(EU)European SHUKO plug 7126:(SA)South African plug
MU
LTI FUN
CTIO
N TESTER
S
54
System Requirements
OS: Windows®7(32/64bit)/VistaDisplay: XGA(Resolution1024x768dots) ormoreHard-disk: Spacerequired20MbyteormoreOthers: WithCD-ROMdriveandUSBport
*Windows® is a registered trade mark of Microsoft in the United States.
3 in 1
3 in 1
250/500/1000V 2/3 POLE 12/1201200Ω
600V
Insulation Earth
ACV
20/200/2000Ω 10/30/100/300/500/1000mA
20/200A/20kA
Loop RCD
PSC
PORTABLE APPLIANCE TESTERS
www.kew-ltd.co.jp
KEW 6201A
MODEL 6202
PO
RTA
BLE
AP
PLI
AN
CE
TEST
ERS
55
TheKEW6201Aisaportableappliancetester,performingfourfunctionstoensuretheSafetyofClass!andClass@appliances.Andalsocanmeasurethemainsvoltage.Readingsaredisplayedonalargeliquidcrystaldisplay(LCD)belowwhicharefourLEDswhichunambiguouslydisplayapassorfailindicationforthresholdvaluesdictatedbyAS/NZS3760.This instrument is suitable for performing tests as required by the following standards. AS/NZS 3760 : 2010 In-service safety inspection and testing of electrical equipment.
TheModel6202isahand-heldportableappliancetester,performingfourfunctionstoensure
theSafetyofClass!,Class@andClass#230Vappliances.Andalsocanmeasurethemains
voltage.
Readingsaredisplayedona large liquidcrystaldisplay (LCD)belowwhichareeightLEDs
whichunambiguouslydisplayapassorfailindicationforthresholdvaluesdictatedbyDINVDE
0701/0702 This instrument is suitable for performing tests as required by the following standards. DIN VDE 0701-1 (240):2000 Repairing, modification and testing of electrical equipment DIN VDE 0702 : 2004 Periodic inspection for electrical equipment
6201ARPE 20Ω Protective Conductor Resistance Test
Measuring range 0~15.00ΩOpen circuit voltage < AC 12VMeasuring current 10A AC nominal valueAccuracy ±3%rdg±5dgt
RINS 200MΩ Insulation ResistanceRating 250V/20MΩ 500V/20MΩMeasuring range 0~19.99MΩOutput Voltage 250V DC (+20%/-10%) @1MΩ 500V DC (+20%/-10%) @1MΩShort circuit current 2.5mA DC or lessAccuracy ±2%rdg±3dgt
Leakage Current TestMeasuring range AC 0.1~19.99mAExamination time Max 15 secondsAccuracy ±3%rdg±5dgt
AC VOLT Mains Voltage CheckMeasuring range 207~264VAccuracy ±2%rdg±3dgt
Supply Voltage 240V±10%Frequency 50Hz±1%Applicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution Degree2,
IEC 61326-1(EMC)Dimensions 185 (L)× 167 (W) × 89 (D) mmWeight 1.2kg (only the instrument body)Accessories 7123 (Power cord [AU]), 7129A (Test leads with Alligator clip)
7161A (Flat test prod) , 7140 (Adapter for Extension Cord)9147 (Cord case), 9121 (Shoulder strap) Instruction manual
Optional 7121B (Distribution board test leads)
6202RPE 20Ω+ / 20Ω- Protective Conductor Resistance Test
Measuring range 0~19.99ΩShort circuit current 200~250mA DC Open circuit voltage ±5.0±0.4V DCAccuracy ±2%rdg±3dgt
RINS 200MΩ Insulation ResistanceMeasuring range 0~19.99/199.9MΩ (2ranges auto)Rated voltage >500V DC (+50%/-0%)Rated current >1mAShort circuit current 14mA(max.)Accuracy ±2%rdg±3dgt
IEL 20mA Equivalent Leakage CurrentMeasuring range 0~19.99mAMeasuring voltage 30V ACInternal resistance (RA Meter) 2kΩAccuracy ±2%rdg±3dgt
IL 2mA Contact CurrentMeasuring range 0~1.999mAInternal resistance (RA Meter) 2kΩAccuracy ±2%rdg±3dgt
VOLT AC VoltmeterMeasuring range 180~260V (50/60Hz)Accuracy ±2%rdg±3dgt
I LINE Current Consumption (6202 only)Measuring range 0~15.99A ACAccuracy ±2%rdg±3dgt
Supply Voltage 230V±10%Frequency 50/60Hz±1%Applicable standards IEC 61010-1 CAT.Ⅲ 300V Pollution Degree2,
IEC 60950, IEC 61326-1(EMC)Dimensions 185 (L)× 167 (W) × 89 (D) mmWeight 1kgAccessories 7125 (Power cord [EU]), 7129A (Test leads with Alligator clip)
7161A (Flat test prod) 9147 (Cord case), 9121 (Shoulder strap) Instruction manual
Optional 7121B (Distribution board test leads)
POWER METER
POWER METERS
KEW 6305
PO
WER
METER
S
• Comprehensivereal-timemonitoring,recordingandanalysisofsingleand3-phase systems
• Voltage,Current,PowerFactorandFrequencymeasurements
• Poweranalysis(Active,ApparentandReactivepower)
• Energyanalysis(Active,ApparentandReactiveenergy)
• Activepoweraccuracy:±0.3%rdg±0.2%f.s.
• Automaticwiringcheckfunctiontopreventincorrectconnections
• Largememorycapability(2GB)usingbuilt-inSDcardInterface
• Recordingintervalcanbesetbetween1secondand1hour.
• Realtime&remotemeasurementsusingAndroidapplication
• WindowssoftwarefordataanalysisandsettingviaUSBportorBluetooth
• SynchronousmeasurementsbetweentwounitsofKEW6305
• Wideselectionofclampsensorsallowmeasurementsfrom0.1Ato3000A
• Theinstrumentautomaticallyrecognizeswhatkindofclampsensorisconnectedtoit
• DoublepowersupplysystemviaAClineandbatteries
6305Wiring connections 1P2W, 1P3W, 3P3W, 3P3W3A, 3P4WMeasurements Voltage, Current, Frequency, Active powerParameters Apparent power, Reactive power, Active energy, Apparent energy,
Reactive energy, Power factor (cos θ), Neutral currentVoltage range[RMS] 150.0/300.0/600.0VVoltage accuracy ±0.2%rdg±0.2%f.s. (sine wave, 45~65Hz)Current range[RMS] 10.00/50.00/100.0/250.0/500.0A/Auto (with clamp sensor MODEL8125)Current accuracy ±0.2%rdg±0.2%f.s.+ Accuracy of Clamp sensor (sine wave, 45~65Hz)
*+1%f.s. at the lowest range.Effective input range 10~110% of rating range Display range 5~130% of each range (Voltage)
1~130% of each range (Current)Crest factor Voltage : up to 2.5, Current : up to 3.0 (with 90% f.s. or less)Active power accuracy ±0.3%rdg±0.2%f.s.+ Accuracy of Clamp sensor
*+1%f.s. when the lowest current ranges is selected.Effect of power factor Active power: ±1.0%rdg cos θ=±0.5 (PF=1)Frequency meter range 40.0~70.0HzFrequency meter accuracy ±3dgtAccuracy precondition PF=1, Sine wave, 45~65Hz, 23°C±5°CDisplay update period 1 secondOperating temperatureand humidity range
0~+50°C, less than 85% RH (without condensation)
Storage temperatureand humidity range
-20~+60°C, less than 85% RH (without condensation)
PC communication interface USB, BluetoothPC card interface SD card (2GB)Safety standard IEC61010-1 CAT.Ⅲ 600VPower supply (AC Line) AC100~240V±10% (50/60Hz)Power supply (DC battery)
LR6 or Ni-MH(HR-15-51)×6 (Battery charger not included), Battery life approx. 15h (LR6)
Power consumption 10VA (max.)Dimension 175(L)×120(W)×65(D)mmWeight Approx. 800g (including batteries)Accessories 7141B (Voltage test lead set: 4pcs), 7148 (USB cable),
7170(Power cord), 9125(Carrying case), 8326-02 (SD card 2GB), KEW WINDOWS (PC Software),Battery(LR6)×6, Quick manual, Calibration certificate
Optionals 8124, 8125, 8126, 8127, 8128 (Clamp sensor),8129 (Flexible clamp sensor),8312 (Power supply adaptor), 9132 (Magnetic carrying case)
NEW
56
Rotate the Rotary switch to SET UP. All the instrument settings can be easily selected by using instrument buttons. All the settings can also be selected by connecting KEW6305 to a PC via USB or Bluetooth.
1. SET UP
Rotate the Rotary switch to WIRING CHECK. The Automatic Wiring check function will prevent incorrect connections, check the connections and display the results on the LCD.Error messages appear on display to indicate wrong orientation of Clamp sensors or in-correct connections.
Everything is OK Error is found
Rotate the Rotary switch to W/Wh/DEMAND. The instrument can perform Instantaneous, Integration and DEMAND measurements.START / STOP button to start / stop recording
2. WIRING CHECK
3. W/Wh/DEMAND Measurements
Shows “Good” Shows “Err” (Error) e.g.: Err PH ACurrent phase (orientation of sensor) may be
incorrect.
Starting from OFF position and rotating the Rotary switch clockwise, KEW6305 is ready to use in 3 simple steps
As easy as 1 2 3 !
Set Model
Optional
POWER METERS
www.kew-ltd.co.jp
PO
WER
MET
ERS
KEW 6305-01
MODEL 8128 MODEL 8127 MODEL 8126 MODEL 8125 MODEL 8124 KEW 8129
MODEL 9132MODEL 8312
57
Download
Free Android software "KEW Smart 6305" is available on download site
Real time & remote measurements using Android application
Measurement can be displayed in graphic or numeric forms on Android devices in real-time via Bluetooth communication.Remote checking of measurements is possible without accessing KEW6305.
Max communication distance: 10m Supporting Android ver. 2.2 - 4.0
Bluetooth is a registered trademark of the Bluetooth SIG, Inc.Android is a registered trademark of the Google Inc.
*communication charges may be incurred separately to download application
Real-time display
Android device
Bluetooth communication with Android application
Automatic creation of graph and list from recorded data.Uniform management of setting and recorded data acquired from multiple devices.Data can be expressed in crude oil and CO2 equivalent val-ues in the report.
Windows software
【System requirements】OS: Windows® 7(32/64bit)/Vista/XPDisplay: XGA(Resolution 1024×768 dots) or moreHard-disk: space required 1Gbyte or moreOther: With CD-ROM drive and USB port .NET Framework (3.5 or more)* Windows® is a registered trademark of Microsoft in the United States.
KEW6305x1MODEL8125x37141B(Voltagetestleadset:4pcs)×17148(USBcable)×17170(Powercord)×18326-02(SDcard[2GB])×19125(Carryingcase)×1PCSoftware×1Battery×6Quickmanual×1Calibrationcertificate
Max amount of data (reference)
SD cards up to 2GB can be used.
*in case the SD card is empty
Data saved on: SD card Internal memoryCapacity 2GB 3MBInstantaneous measurement 6,670,000 10,000
Integration / demandmeasurement interval
1 sec. 17 days 33 minutes1 min. 992 days 33 hours30 min. 3 years or more 42 days
Max number of file 511 4
Load current clamp sensors Load current flexible clamp sensors
8129-01(for1ch)8129-02(for2ch)8129-03(for3ch)FLEXIBLECLAMPSENSORWITH3RANGESAC300,1000,3000A
Power supply adaptor Magnetic carrying case
For taking singlephase supply(100-240V)fromthetestleadstopowertheinstrument
Formountinginsidemetaldistributionboards
SD card Interface
Ø24 Ø24 Ø40 Ø40 Ø68 Ø150AC 5A(MAX 50A)
MAXAC 100A
MAXAC 200A
MAXAC 500A
MAXAC 1000A
MAXAC 3000A
POWER QUALITY ANALYZER
To monitor the Quality of Power and cut-ting Energy costs through consumption measurements!
POWER METERS
KEW 6310
6310
PO
WER
METER
S
58
• 12kindsofPowerMeasurementsforPowerControlandApplicabletoPowerQual-ityControlincludingHarmonicsAnalysis.
• Oneclickeasy-to-useoperationhelpscomplicatedsettingandprocessingoflargedatathroughthesetting/analyzingsoftwareprovidedasaccessory.
• DirectcommunicationwithPCviaUSBcable.
• Built-inInput/OutputFunctionofexternalsignalenablesthesignaltransmissiontoalarms.
• 2-waypowersupplybyACandBattery,andNickelhydrogenbatteryusablewithrechargeablefunction.
• Pull / InsertofCFcardpossiblewheneveronrecordingunder the functionofmemorybackupdevice.
• Canmonitorinsulationatleakagecurrentbyusingoptionalleakclampsensors.
• Built-inPrintScreenFunctionenables to recorddisplayscreen (Records512screensbyusingCFcard:1screen40KB).
• CandisplayWaveformandVector,andcanconfirmthewiringconnection,too.
• CompliesfullywithInternationalSafetyStandardsIEC61010-1CAT.Ⅲ 600V.
Wiring connections 1P 2W, 1P 3W, 3P 3W, 3P 4WMeasurements and parameters
Voltage, Current, Frequency, Active power, Reactive power,Apparent power, Active energy, Reactive energy, Apparent energy,Power factor (cos θ), Neutral current, Demand, Harmonics,Quality (Swell/Dip/Instantaneous stop, Transients/Over voltage,Inrush Current, Unbalance Rate), Phase advance condenserIEC Flicker [Pst (1 min)*, Pst, Plt] * Pst can be shown in details for 1 minute intervals.
Other functions Digital output function, External communication function,Scaling function
Voltage [RMS]Range 150 / 300 / 600 / 1000VAllowable input 10~110% of each rangeDisplay range 5~120% of each rangeCrest factor 2.5 or less (100% or less of each range)Accuracy ±0.3%rdg ±0.2%f.s. (sine wave, 45~65Hz)
Current [RMS]Range 8128 ( 50A type ): 1 / 5 / 10 / 20 / 50A
8127 ( 100A type ) : 10 / 20 / 50 / 100A 8126 ( 200A type ) : 20 / 50 / 100 / 200A 8125 ( 500A type ) : 50 / 100 / 200 / 500A8124 ( 1000A type ) : 100 / 200 / 500 / 1000A8129 ( 3000A type ) : 300 / 1000 / 3000A
Allowable input 10~110% of each rangeDisplay range 1~120% of each rangeCrest factor 3.0 or less (90% or less of each range)Accuracy ±0.3%rdg ±0.2%f.s. + Accuracy of Clamp sensor (sine wave, 45~65Hz)
Active powerRange Depending on combinations of (V Range) x (A Range)Accuracy ±0.3%rdg ±0.2%fs + Accuracy of Clamp sensor
(Power factor 1, Sine wave 45~65 Hz)Influence of power factor ±1.0% rdg (reading at power factor 0.5 against power factor 1)
Frequency meter range 40~70HzInternal memory 1.8MB (Measurement file [CSV] ×6 blocks,
Screen file [BMP] ×7 blocks, Configuration file [KAS] ×20 blocks)Display 320×240 (RGB) Pixel, 3.5-inch color STN displayTemperature & humidity range
23˚C±5˚C, Relative humidity 85% or less (no condensation)
Storage temperature & humidity range
-20˚C±60˚C, Relative humidity 85% or less(no condensation)
Operating temperature & humidity range
0˚C±40˚C, Relative humidity 85% or less(no condensation)
PC Card type Compact flash card (Capacity: 32 / 64 / 128 / 256 / 512MB / 1 / 2 / 4 / 8GB)*The CF card larger than 2GB is usable, however, the possible stored size will be
limited to 2GB. For example, when the CF card of 4GB or 8GB is used, the maxi-mum stored size will be 2GB.
Applicable standards IEC 61010-1 CAT.Ⅲ 600V Pollution degree 2IEC 61010-031, IEC 61326
Power supply AC 100V~240V±10% (45~65Hz)Alkaline size AA battery LR6 (9V 1.5V × 6) or Ni-MH (HR15-51)
Dimensions 175(L)×120(W)×68(D) mmWeight approx. 900g (including batteries)Accessories 7141B(Voltage test lead set), 7148 (USB Cable),
7170 (Power Cord)8307 (Compact flash card [128MB]), 8319 (CF Card reader)9125 (Carrying case), Input terminal plate (6-kind)Alkaline size AA battery (LR6) × 6, Cable marker × 32KEW PQA MASTER (PC Software), Quick manual
Optional 8124, 8125, 8126, 8127, 8128 (Load current clamp sensor)8129 (Flexible clamp sensor)8146, 8147, 8148 (Leakage & Load current clamp sensor)8141, 8142, 8143 (Leakage clamp sensor) 8322 (Compact flash card [256MB]), 8323 (Compact flash card [1GB]) 8325F (Flicker sensor), 8312 (Power supply adaptor) 9132 (Carrying case with magnet)
Equipped with the Flicker measurement functionFlicker can be measured by using flicker sensor KEW8325F of the option.
Recordable Number of Data Point / Approx. Time
CF Card Interface LoadedExternalMemoryupto1GBAvailable.*1
Analysis SoftSupplied !
Easy-to- use setting- up and analyzing with KEW PQA MASTER supplied.
Direct Data Transmission to PC via USB
【System requirements】OS: Windows® 7(32/64bit)/Vista/XPDisplay: XGA(Resolution 1024×768 dots)or moreHard-disk: Space required 100Mbyte or moreOthers: With CD-ROM drive and USB Port* Windows® is a registered trademark of Microsoft in the United States.
KEW 8325FFlicker sensor
V measurementPst(1min) measurement
Plt measurement
Set ModelConsistsof:6310×17141B(Voltagetestleadset)7148(USBcable)7170(Powercord)8307(CompactFlashcard[128MB])8319(CFcardreader)9125(Carryingcase)KEWPQAMASTER(PCsoftware)Inputterminalplate(6-kind)QuickmanualAlkalinesizeAAbattery(LR6)×6Cablemarker×32
Model ClampsensorKEW 6310-00 —KEW 6310-01 8125(500A) × 3KEW 6310-02 8125(500A) × 2KEW 6310-03 8124(1000A) × 3KEW 6310-04 8124(1000A) × 2KEW 6310-05 8126(200A) × 3KEW 6310-06 8126(200A) × 2KEW 6310-07 8127(100A) × 3KEW 6310-08 8127(100A) × 2KEW 6310-09 8128(5A) × 3KEW 6310-10 8128(5A) × 2KEW 6310-11 8129-03 × 1KEW 6310-12 8129-02 × 1
POWER METERS
www.kew-ltd.co.jp
PO
WER
MET
ERS
59
Power Consumption (Energy) Control
Instantaneous value measurement / saving
Integration value measurement / saving
Demand value measurement / saving
Measures Current / Voltage / Instantaneous averaged value of Power etc. / Maximum value / Minimum value.
Measures Active power energy / Apparent power energy / Reactive power energy.
Sets Demand target value and measures De-mand value from start to stop of measurement. Can warn with digital output terminal when the set value exceeds the target value.
Wave Range Measurement / Saving
Harmonics Measurement / Saving
Quality
Displays vector / waveform corresponding to voltage and current of each channel.
Measures and analyzes harmonics contents of current and voltage of each phase.
Can measure Swells / Dips / Interruptions, Tran-sients, Inrush current, Unbalanced, and can simulate power factor correction with capacitor banks.
Power Quality Control
Destination to save data CF Card Internal Memory
Capacity 32MB 64MB 128MB 256MB 512MB 1GB 1.8MB
Instantaneous value measurement1sec 15H 1D 2D 5D 10D 20D 7min1min 10D 20D 1M 2M 5M 10M 2H
30min 10M 1Y Over 1Y Over 1Y Over 1Y Over 1Y 2D
Integration value measurement1sec 6H 13H 1D 2D 4D 8D 3min1min 7D 15D 1M 2M 4M 8M 1H
30min 7M 1Y Over 1Y Over 1Y Over 1Y Over 1Y 1D
DEMAND measurement 1sec 4H 8H 17H 1D 2D 5D 2min1min 6D 12D 24D 1M 3M 6M 1H
30min 6M 1Y Over 1Y Over 1Y Over 1Y Over 1Y 1D
WAVE range 10sec 1D 3D 7D 14D 28D 1M 20min1min 10D 21D 1M 2M 5M 11M 2H
30min 10M 1Y Over 1Y Over 1Y Over 1Y Over 1Y 2D
Harmonic analysis 15sec 3D 7D 15D 1M 2M 4M 44min1min 15D 1M 2M 4M 8M 1Y 2H
30min 1Y Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y 3D
Swell / Dip / Int measurement *2 1sec 2D 5D 11D 22D 1M 2M 32min1min 5M 11M 1Y Over 1Y Over 1Y Over 1Y 1D
30min Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y 1M
Transient measurement *2 1sec 3D 6D 12D 24D 1M 3M 35min1min 6M 1Y Over 1Y Over 1Y Over 1Y Over 1Y 1D
30min Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y 1M
Inrush current measurement *2 1sec 2D 5D 11D 22D 1M 2M 32min1min 5M 11M 1Y Over 1Y Over 1Y Over 1Y 1D
30min Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y 1M
Unbalance rate 1sec 21H 1D 3D 7D 14D 27D 10min1min 14D 29D 1M 3M 7M 1Y 2H
30min 1Y Over 1Y Over 1Y Over 1Y Over 1Y Over 1Y 3DFlicker *3 1min 7M 1Y Over 1Y Over 1Y Over 1Y Over 1Y 1D
Capacitance calculation 1sec 15H 1D 2D 5D 10D 19D 7min1min 10D 20D 1M 2M 5M 10M 1H
30min 10M 1Y Over 1Y Over 1Y Over 1Y Over 1Y 2D
Max number of file
Measurement data file (CSV)
512
6
Graphics file (BMP) 7
Configuration file (KAS) 20
* In case that no file exist in the CF card or the Internal memory.where: H= hour(s), D=day(s), M=month(s), Y=year(s)
*1 Downloading data from CF cards needs the optional card reader (8319) or card readers being on sale.*2 Assumed one event occur per minute and calculated.*3 Flicker measurement function is only available with ver.2.00 or later.
Can measure Flicker in accordance to IEC61000-4-15 and EN 50160 stan-dards. Using our Flicker sensor, avail-able as optional accessory, Pst value (short term severity in 10 minutes val-ue) and the Plt value (long term severity in 2 hours value) can be measured.
photo : 6310-01
Optional Accessories of Loggers, Power Meter and Power Quality Analyzer
Applicable model table
Power supply adaptorMODEL 8312Power source can be taken through the measured line (100~240v)
MODEL 8320
• Appropriateforalongerperiodofrecording.• Compliesto 90~264V(45~66Hz).
Dimensions :250(L) × 270(W) × 216(D)mm
AC adaptor (External power supply)
MODEL 9135Carrying case
Carrying case with magnetMODEL 9132
Easy-to-use setting with magnet on the steel plate etc. of switch board
KEW 8309
KEW 8325F
Floating Voltagecan be measured*Floating voltage :
phase to phase voltage not grounded
* KEW 5020-01 : KEW 5020 logger with KEW 8309 (1pce.)
Voltage sensor
Flicker sensor
CanmeasureFlickerincombinationwithKEW6310
SENSORS
SENSO
RS
60
5001 5010 5020 6305 6310
Sensor Load current 8121
8122
8123
8124
8125 *1 *1
8126 *2 *2
8127 *3 *3
8128
8129 *4 *5
Leakage current 8141*6
8142*6
8143*6
Leakage & Load current
8146*6
8147*6
8148*6
Voltage sensor 8309
Flicker sensor 8325F
Adaptor 8312
8320
Case 9132
9135 *1~5: Can use with after the following serial numbers.
*1: No.02637~ *2: No.00151~*3: No.00181~*4: No.8029792~*5: No.8031560~*6: Cannot be used for power measurement.
Load current Clamp sensors
MODEL 8127 MODEL 8126 MODEL 8125 MODEL 8124
MODEL 8128KEW 8129
8129-01 (for 1ch) 8129-02 (for 2ch)8129-03 (for 3ch)
FLEXIBLE CLAMP SENSOR CAN MEASURE UP TOAC3000A HIGH CURRENT
SENSORS
www.kew-ltd.co.jp
8129-01 (for 1ch) 8129-02 (for 2ch) 8129-03 (for 3ch) 8128Conductor size max. φ150mm φ24Rated current 300/1000/3000A AC 5A (Max.50A)Output voltage 300A Range :AC500mV/AC300A (1.67mV/A)
1000A Range :AC500mV/AC1000A (0.5mV/A)3000A Range :AC500mV/AC3000A (0.167mV/A)
AC 50mV/5A[Max. 500mV/50A](AC 10mV/A)
Accuracy ±1.0%rdg (45~65Hz) ±0.5%rdg±0.1mV (50/60Hz) ±1.0%rdg±0.2mV (40Hz~1kHz)Phase shift within ±1° within ±2.0° (45~65Hz)Cable length Output connector Sensor part : approx. 2m Output cable : approx. 1m MINI DIN 6PIN Approx. 3m : MINI DIN 6pinOperating temperature &humidity ranges
0~50˚C, relative humidity 85% or less (no condensation) -0~50˚C, less than 85% RH (without condensation)
Output impedance 100Ω or less Approx. 20ΩApplicable standards IEC 61010-1, IEC 61010-2-032 CAT.Ⅲ 600V Pollution degree2, IEC 61326 IEC 61010-1, IEC 61010-2-032
CAT.Ⅲ 300V pollution degree 2, IEC 61326Dimensions 111(L) × 61(W) × 43(D) mm (except for protrusions) 100(L) × 60(W) × 26(D)mmWeight Approx. 410g Approx. 680g Approx. 950g Approx. 160gAccessories Instruction manual
7199 (Output cable) × 19137 (Carrying case)
Instruction manual7199 (Output cable) × 29137 (Carrying case)
Instruction manual7199 (Output cable) × 39137 (Carrying case)
9095(Carrying case) Instruction manual Cable marker
Optional − 7146(Banana φ4 adjuster plug) 7185(Extension cable)Applicable models 5010, 5020, 6305, 6310 6305, 6310
8127 8126 8125 8124Conductor size φ24 φ40 φ40 φ68Rated current AC 100A AC 200A AC 500A AC 1000AOutput voltage AC 500mV/100A (AC 5mV/A) AC 500mV/200A (AC 2.5mV/A) AC 500mV/500A (AC 1mV/A) AC 500mV/1000A (AC 0.5mV/A)Accuracy ±0.5%rdg±0.1mV (50/60Hz)
±1.0%rdg±0.2mV (40Hz~1kHz)±0.5%rdg±0.1mV (50/60Hz)±1.5%rdg±0.4mV (40Hz~1kHz)
Phase shift within ±2.0° (45~65Hz) within ±1.0° (45~65Hz)Cable length : Output connector Approx. 3m : MINI DIN 6pinOperating temperature ranges -0~50˚C, less than 85% RH ( without condensation)Output impedance Approx. 10Ω Approx. 5Ω Approx. 2Ω Approx. 1ΩApplicable standards IEC 61010-1, IEC 61010-2-032
CAT.Ⅲ 300V pollution degree 2IEC 61326
IEC 61010-1, IEC 61010-2-032 CAT.Ⅲ 600V pollution degree 2 IEC 61326
Dimensions 100(L) × 60(W) × 26(D)mm 128(L) × 81(W) × 36(D)mm 186(L) × 129(W) × 53(D)mmWeight Approx. 160g Approx. 260g Approx. 510gAccessories 9095 (Carrying case) Instruction manual Cable marker 9094 (Carrying case) Instruction
manual cable markerOptional 7146 (Banana φ4 adjuster plug) 7185 (Extension cable)Applicable models 6305, 6310
SEN
SOR
S
61
Ø150 Ø24MAX 3000A
MAX 50A
Ø68Ø40Ø40Ø24 MAX 1000A
MAX 500A
MAX 200A
MAX 100A
Leakage & Load current Clamp sensors
Load current Clamp sensors
KEW 8146
KEW 8121
KEW 8147
KEW 8122
KEW 8148
KEW 8123
SENSORS
8146 8147 8148Conductor size φ24 φ40 φ68Rated current AC 30A AC 70A AC 100AOutput voltage AC 1500mV/30A (AC 50mV/A) AC 3500mV/70A (AC 50mV/A) AC 5000mV/100A (AC 50mV/A)Accuracy 0~15A
±1.0%rdg±0.1mV (50/60Hz)±2.0%rdg±0.2mV (40Hz~1kHz)15~30A±5.0%rdg (50/60Hz)±10.0%rdg (45Hz~1kHz)
0~40A±1.0%rdg±0.1mV (50/60Hz)±2.0%rdg±0.2mV (40Hz~1kHz)40~70A±5.0%rdg (50/60Hz)±10.0%rdg (45Hz~1kHz)
0~80A±1.0%rdg±0.1mV (50/60Hz)±2.0%rdg±0.2mV (40Hz~1kHz)80~100A±5.0%rdg (50/60Hz)±10.0%rdg (45Hz~1kHz)
Cable length : Output connector Approx. 2m : MINI DIN 6pinOperating temperature ranges -0~50˚C, less than 85% RH (without condensation)Output impedance Approx. 90Ω Approx. 100Ω Approx. 60ΩApplicable standards IEC 61010-1, IEC 61010-2-032
CAT.Ⅲ 300V pollution degree 2, IEC 61326Dimensions 100(L) × 60(W) × 26(D)mm 128(L) × 81(W) × 36(D)mm 186(L) × 129(W) × 53(D)mmWeight Approx. 150g Approx. 240g Approx. 510gAccessories 9095(Carrying case) Instruction manual Cable marker 9094 (Carrying case) Instruction manual Cable markerOptional 7146(Banana φ4 adjuster plug) 7185(Extension cable)Applicable models 5010, 5020, 6310*
*Cannot be used for power measurements.
8121 8122 8123Conductor size φ24 φ40 φ55Rated current AC 100A AC 500A AC 1000AOutput voltage AC 500mV/100A (AC 5mV/A) AC 500mV/500A (AC 1mV/A) AC 500mV/1000A (AC 0.5mV/A)Accuracy ±2.0%rdg±0.3mV (50/60Hz)
±3.0%rdg±0.5mV (40Hz~1kHz)Cable length : Output connector Approx. 2m : MINI DIN 6pinOperating temperature ranges -0~40˚C, less than 85% RH (without condensation)Output impedance Approx. 9.5Ω Approx. 1.9Ω Approx. 1.5ΩApplicable standards IEC 61010-1,
IEC 61010-2-032CAT.Ⅲ 300V pollution degree 2, IEC 61326
IEC 61010-1, IEC 61010-2-032CAT.Ⅲ 600V pollution degree 2, IEC 61326
Dimensions 97(L) × 59(W) × 26(D)mm 128(L) × 81(W) × 36(D)mm 170(L) × 105(W) × 48(D)mmWeight Approx. 150g Approx. 260g Approx. 360gAccessories 9095(Carrying case) Instruction manual Cable marker 9094(Carrying case) Instruction manual Cable markerOptional 7146(Banana φ4 adjuster plug) 7185(Extension cable)Applicable models 5010, 5020
SENSO
RS
62
Ø24
Ø24
Ø40
Ø40
Ø68
Ø55
MAX 30A
MAX 100A
MAX 70A
MAX 500A
MAX 100A
MAX 1000A
AC DC
Leakage current Clamp sensors
AC/DC clamp sensor
MODEL 8141 MODEL 8142 MODEL 8143
SENSORS
www.kew-ltd.co.jp
KEW 8115 8115Measuring range AC 0.1~130Arms DC 0~±180AOutput voltage AC 10mV/A DC 10mV/AAccuracy ±1.2%rdg±0.4mV (50/60Hz)
±2.5%rdg±0.4mV (40Hz~1kHz)±1.2%rdg±0.4mV (*)
Low battery warning 2.2V±0.2V or less - Red LED flash(1.9V±0.2V - Automatically power off)
Conductor size φ12mm max. Operating temperature & humidity range
-10 to 55ºC, relative humidity 85% or less (no condensation)
Output impedance Approx. 10Ω or lessApplicable standards
IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2,IEC 61010-2-032, IEC 61326-1
Power source DC3V (size AAA alkaline battery LR03×2pcs)*Continuous use: approx. 40 hours(Auto power off: approx. 20 minutes)
Cord length Approx. 1,200mmOutput connector φ4mm banana plugDimensions 127(L)×42(W)×22(D) mmWeight Approx. 140gAccessories Soft case, LR03×2, Instruction manualApplicable model 1009,1011,1012,1051,1052,1061,1062
8141 8142 8143Conductor size φ24 φ40 φ68Rated current AC 1000mA AC 1000mA AC 1000mAOutput voltage AC 100mV/1000mA(AC 100mV/A)Accuracy ±1.0%rdg±0.1mV(50/60Hz)
±2.0%rdg±0.1mV(40Hz~1kHz)Cable length : Output connector Approx. 2m : MINI DIN 6pinOperating temperature ranges -0~50˚C, less than 85% RH (without condensation)Output impedance Approx. 180Ω Approx. 200Ω Approx. 120ΩApplicable standards IEC 61010-1, IEC 61010-2-032
CAT.Ⅲ 300V pollution degree 2, IEC 61326Dimensions 100(L) × 60(W) × 26(D) mm 128(L) × 81(W) × 36(D) mm 186(L) × 129(W) × 53(D) mmWeight Approx. 150g Approx. 240g Approx. 490gAccessories 9095(Carrying case) Instruction manual 9094(Carrying case) Instruction manualOptional 7146(Banana φ4 adjuster plug) 7185(Extension cable)Applicable models 5001, 5010, 5020, 6310
*Cannot be used for power measurements.
SEN
SOR
S
63
Ø12 DCAC A AUTO POWER
OFFMAX 130A
MAX 180A
Ø24 Ø40 Ø68MAX 1000mA
MAX 1000mA
MAX 1000mA
DIGITAL ILLUMINOMETER
DIGITAL LIGHT METER
Waterproof handheldInfrared Thermometer
Relation of Distance and Measuring Diameter
500
1000
90 45 17
OTHERS
MODEL 5201
MODEL 5202
MODEL 5510
5201Ranges 0.1~19990Lux(automatic 3 range switching)Accuracy ±5%rdg±1dgtMeasuring time 2 times per secondTemperature humiditycharacteristics
±3%(at 20°C)
Angular incidentlight characteristics
10° Less than ±1.5%30° Less than ±3%60° Less than ±10%80° Less than ±30%
Spectral responsecharacteristics
Closely related to the spectralluminous efficiency (of a standard observer).
Power source 6F22(9V) × 1Dimensions 166(L) × 68(W) × 32(D)mmWeight 180g approx.Accessories Photocell cover
6F22 × 1Soft carrying case Instruction manual
5202Ranges 0.1~19990LuxAccuracy(23°C±5°C)
Lux Accuracy200 ±(4% rdg+5 dgt)2000 ±(4% rdg+5 dgt)20000 ±(5% rdg+4 dgt)
Current consumption 2mA approxResponse time 2.5 times / sec.Operating temperature range 0~50°C Below 80% RHStorage temperature range -10°C~60°CAngular incidentlight characteristics
30°Less than ±3% 60°Less than ±10% 80°Less than ±30%
Power source 6F22(9V) × 1Dimensions Meter:148(L) × 71(W) × 36(H)mm
Light receiving sensor:85(L) × 67(W) × 32(H)mmWeight 270g approx.Accessories Carrying case
6F22(9V) × 1Photocell coverInstruction manual
5510Measuring range -40°C~300°CDetecting element ThermopileSpectral range 6.5µm or moreDisplay resolution 0.5°C 1°C for below -20°C and over 100°CMeasuring accuracy When the ambient temperature is 25±2°C and the emissivity (e) is 1,
0~300°C : bigger value of either of ±1% of the mea-sured value ±1dgt or ±2°C ±1dgt.
0~-30°C : ±3°C ±1dgtbelow -30°C : ±5°C ±1dgt
Repeatability within 1°C ±1dgtResponse 1 sec(90% response)Measuring diameter φ45mm/500mm(Optical sensitivity: 90%)Collimation Before shipment: 0.95. The value can be altered between 0.8
and 1.0 (by 0.05 steps).Laser beam(650nm 1mW JIS class2)specifies the center.
Auto power off If no key is pressed for 30 seconds, the power is shut off automatically.Operating temperature 0~50°COperating humidity 90% rH and below(no condensation)Storage temperature -20~55°C(no condensation)Battery 2 AAA alkaline cell batteriesBattery life Approximately 10 hours for continuous useDimensions 120 × 60 × 54mm(Maximum value for each direction)Weight Approx. 123gAccessories 2 AAA alkaline cell batteries, instruction manual, strapApproved standard CE marking:EMI EN61326 Class B EMS EN61326 Annex C
Stability:±5°C under EMC test environment at 25°C
OTH
ERS
• Model5201isahighlyportableandcompactdigital illuminometer formeasuring illuminance from0.1 to19,990Lux,withautorangeswitch-ing.
• Thedigitaldisplayisheldforapresettime(about20seconds)and,there-fore,facilitatesreading,recordingandmeasuringinanydirection.
• 3rangeschangeablefromlowtohighilluminance.
(200/2000/20000Lux)
• Dataholdfunction.
• Digitallightmeterwithseparatelightreceivingsensorandmeter.
• Safeevenifgettingwet. DustproofandwaterproofstructureofIP67.
• Possibletowash
• Pleasefeelsecuretousetheproductonthespot,madefromABSresinofantibacterialspecification.
• Shock-proofstructure:Nodamageevenifdroppedfromtheheightof1m.
• Withauto-power-off function,pre-ventingconsumptionofthebattery
• WideTemperatureRangeof-40°Cto300°C
• Smallandlight:Possibletomeasureeasilybyonehand.
• Portabletype:Convenienttocarry
64
Non-Contact Safety Phase Indicator
DIGITAL PHASE INDICATOR with open phase checker
PHASE INDICATOR withfused test leads
PHASE INDICATOR with open phase checker
8035Functions Phase rotation (Clockwise or Counter Clockwise),
Presence of open phaseDetection method Electrostatic inductionMeasuring voltage range From 70~1000V AC phase to phase
(sine wave, continuous input)Clamp diameter range From φ2.4 to 30mm insulated cablesMeasuring frequency range
45 to 66Hz
Phase rotation Clockwise: Green arrow LEDs “rotate” in clockwise, Green symbol “CW” lits, Intermittent buzzerCounter Clockwise: Red arrow LEDs “rotate” in counter clockwise, Red symbol “CCW” lits, continuous buzzer
Visual indication Via LEDs with Super brightness functionBattery voltage warning Power LED blinks if battery voltage is too low.Operating temperature& humidity range
-10 to 50ºC, relative humidity 80% or less(no condensation)
Storage temperature& humidity range
-20 to 60ºC, relative humidity 80% or less(no condensation)
Applicable standards IEC 61010-1 CAT. Ⅳ 600V, CAT. Ⅲ 1000V Pollution degree2Power supply Alkaline battery (LR6) × 4
* Continuous use: Approx. 100 hours (Auto power off in about 10 min.)
Dimensions 112(L) × 61(W) × 36(D) mmWeight Approx. 380gTest leads Double insulated cables, length approx. 70cmColours code L1(U): RedL2(V): WhiteL3(W): BlueAccessories included 9096 (Carrying case), Alkaline battery (LR6) × 4,
Instruction manual
8030CE Type Standard Type
Operational voltage 200~480V ACTime limit forcontinuous
200V : within 60 minutes480V : within 4 minutes
Frequency response 20~400HzApplicable standards IEC 61010-1 CAT.Ⅲ 300V
Pollution degree 2—
Dimensions 82(L) × 59(W) × 23(D)mmcontinuous 200g approx.Cord 1m(R: red S : white T : blue)Accessories 9070(Carrying case) Pins for test leads
Instruction manual
8031 8031FCE Type Standard Type
Operational voltage 110~600V ACFuse — 0.5A/600V (F)Time limit for continuous >500V : within 5 minutesFrequency response 50/60HzApplicable standards IEC 61010-1 CAT. Ⅲ 600V
Pollution degree 2—
IEC 61010-1 CAT.Ⅲ 600VPollution degree 2
Dimensions 106(L) × 75(W) × 40(D)mmWeight 350g approx.Cord 1.5m(R : red S : white T : blue)Accessories 9029(Carrying case)
Instruction manual9094(Carrying case) Instruction manual
OTHERS
www.kew-ltd.co.jp
KEW 8035
MODEL 8030
MODEL 8031/KEW 8031FO
THER
S
• Newtechnologypermitssafetesting,withouttheneedofdirectcontactbetweenprobesandlivewires.
• Theinsulatedcrocodileclipscanclipinsulatedcablesfromφ2.4to30mm.
• PhaserotationisindicatedbytherotaryilluminationofLEDsandlogicalaudibletones.
• Theinstrumentcanbefixedtoametalpanelviathemagnetonthebackside.
• Widemeasuringrangefor3phaseinstallationsfrom70Vto1000VAC.
• SuperbrightnessfunctionpermitsclearLEDsindicationalsoinsunshine.
• PhaseindicatordesignedtocheckthepresenceofopenphaseandalsothephasesequencebyLEDandbuzzeratthesametime.
• Small,lightweight,andportable.
• Phaseindicatordesignedtocheckthepresenceofopenphaseandalsothephasesequence byrotatingdiskandlamps.
• Cancheckawiderangeof3-phasepowersourcefrom110Vto600V. Sealedagainstdust,theunitensurestrouble-freeperformance.
• Small,Lightweightandportable.Designedformaximumeaseofoperationandruggedness.
• Noexposedmetalparts,Safetyfeaturesareincorporatedincludingthe instantpushbuttonswitchoperation.(8031FOnly)
65
CE type
Standard type
MODEL 8031Standard type
MODEL 8031CE type
photo : 8031F
AC CLAMP METER
AC/DC CLAMP METER
KEWTECH
KT 200
KT 203
KT 200AC A 40.00/400.0A
±2.0%rdg±6dgt(50/60Hz)AC V 400.0/600V(Auto-ranging)
±2.0%rdg±5dgt(50/60Hz)DC V 400.0/600V(Auto-ranging)
±1.5%rdg±5dgt
Ω 400.0/4000Ω(Auto-ranging)±2.0%rdg±5dgt
Continuity buzzer buzzer sounds below 50±35ΩConductor size φ30mm max.Applicable standards IEC 61010-1 CAT.Ⅲ 300V(ACA), CAT.Ⅱ 600V Pollution degree 2
IEC 61010-031, IEC61010-2-032, IEC61326-1Power source R03(1.5V)(AAA) x 2
*Continuous measuring time:approx.200 hours(Auto power save: approx.10 minutes)
Dimensions 184(L) x 68.6(W) x 38.5(D)mmWeight Approx. 190g(including batteries)Accessories 7066A(Test leads), R03(AAA) x 2, Instruction manual Optional 9105(Carrying case)
KT 203AC A 40.00/400.0A (Auto-ranging)
±3.0%rdg±8dgt[50/60Hz](0~40.00A)±3.5%rdg±6dgt[50/60Hz](15.0~299.9A)±4.0%rdg±6dgt[50/60Hz](300.0~400.0A)
DC A 40.00/400.0A (Auto-ranging)±3.0%rdg±8dgt (0~40.00A)±3.5%rdg±6dgt (15.0~299.9A)±4.0%rdg±6dgt (300.0~400.0A)
AC V 400.0/600V(Auto-ranging)±2.0%rdg±5dgt(50/60Hz)
DC V 400.0/600V(Auto-ranging)±1.5%rdg±5dgt
Ω 400.0/4000Ω(Auto-ranging)±2.0%rdg±5dgt
Continuity buzzer buzzer sounds below 50±35ΩConductor size φ30mm max.Applicable standards IEC 61010-1 CAT.Ⅲ 300V(ACA), CAT.Ⅱ 600V Pollution degree 2
IEC 61010-031, IEC61010-2-032, IEC61326-1Power source R03(1.5V)(AAA) x 2
*Continuous measuring time:approx.35 hours(Auto power save: approx.10 minutes)
Dimensions 187(L) x 68.5(W) x 38.5(D)mmWeight Approx. 200g(including batteries)Accessories 7066A(Test leads), R03(AAA) x 2, Instruction manualOptional 9105(Carrying case)
KEW
TECH
• Smallandhandyclampmeter
• IEC61010-1SafetyStandardCAT. Ⅲ300V,CAT.Ⅱ600V
• 400AACClampmeter
• DMMfunctionACV,DCV, ΩContinuityBuzzer.
• Smallandhandyclampmeter
• IEC61010-1SafetyStandardCAT. Ⅲ300V,CAT.Ⅱ600V
• 400AAC/DCClampmeter
• DMMfunctionACV,DCV, ΩContinuityBuzzer.
66
AC A
DCAC A
DCAC V
DCAC V
Ω
Ω
Ø30
Ø30
MAX 400A
MAX 400A
DATAHOLD
DATAHOLD
AUTO POWERSAVE
AUTO POWERSAVE
VOLTAGE TESTER
KEWTECH
www.kew-ltd.co.jp
KT 170/171
KEW
TEC
H
• ComplywiththelateststandardsIEC61243andIEC61010
• Noveldesign LargeandbrightLEDs:Valuesarevisibleinthedarkplace. Ergonomicdesignfitsinthehand.
• Twofunctionsareavailableinonemodel. “Measurementwithoutbattery”and“SelfTest(allLEDon)”
• Testleadswithstandharshenvironmentsatlowtemperature.
• Penlight(whiteLED)
• Auto-powerON/OFF
• Audibleindication
• Variabletesttips,φ2mmorφ4mm
• Probeprotectioncovercanstoretheattachmentofcaps.
• IP65(IEC60529)
• ThevoltageisindicatedbyLEDs.
Buzzer soundsandLivecircuitLEDlightsupwhenathresholdvoltageof50Visexceeded.
• Voltagepolarityisindicatedinfollowingmanner.
KT170/171Voltage test
Voltage range 12~690V AC/DCLED
Nominal voltage 12/24/50/120/230/400/690VAC(16~400Hz), DC(±)
Tolerance(Threshold voltage)
Light on at more than:7±3V (12V LED)18±3V (24V LED)37.5±4V (50V LED)75%±5% of nominal voltage (120/230/400/690V LED)
Response time < 0.6s at 100% of each nominal voltageLCD (KT171 only )
Range / Resolution(Auto-range)
300V AC/DC (6.0~299.9) / 0.1V690V AC (270~759) / 1V690V DC (270~710) / 1V
Accuracy (23±5°C) ±1.5V (7~100V)±1%±5dgt (100~690V)AC(16~400Hz), DC(±)
Over limit indication “OL”Response time < 2s at 90% of each voltage
Peak current Is<3.5mA (at 690V)Measurement Duty 30s ON (operation time)
240s OFF (recovery time)Single-pole phase test
Voltage range 100~690V AC (50/60Hz)Phase rotation test
System Three-phase 4-wire system 200~690V phase-to-phase AC (50/60Hz)
Phase range 120±5 degreeContinuity test
Detection range 0~400kΩ + 50%Test current Approx. 1.5µA (battery 3V, 0Ω)
Operating temperature and humidity ranges
-15~55°C, max 85% RH (No condensation)
S torage temperature and humidity ranges
-20~70°C, max 85% RH (No condensation)
Applicable standards IEC61243-3, IEC61010-1, IEC61010-031, IEC61557-7CAT.# 690V / CAT.$ 600V Pollution degree 2, IEC60529 (IP65)
Power source LR03(AAA) 1.5V x 2Dimensions 246 x 64 x 26mmWeight 195g (including batteries) Accessories LR03(AAA) 1.5V x 2, KTA01(4mm metal tips[2pcs/set]),
KTA02(4mm rubber caps[2pcs/set]), Instruction manualKT170AUisavailableforAustraliaandNewZealandmarket.
NEW
67
AC +DC -DC
Probe ProtectionCover
Bright LEDs and PenlightVoltage Test (Double-pole Test) Single-pole Phase Test
Variable top tips Store the attachment of caps
KTA02(4mmrubbercaps)
KTA01(4mmmetaltips)
photo : KT170 photo : KT171
Plug φ4 Plug φ4
Plug φ4
Plug φ4
Plug φ4Plug φ4
Plug φ4
Plug φ4
Guard cord
Earth and guard leads
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Temperatureprobe
2WAY Output cord
Lead for recorder Lead for battery charging
Plug φ4 Plug φ4
Earth resistance test leads
Plugphoto : 7103A
7139A7103A
7103A 7139A
Testleadswithremotecontrolswitch
Plug φ4
ACCESSORIES
AC
CESSO
RIES
68
7019 1,500mm
5402D
7025 1,500mm
3001B31653166
7066A 706710091011101211102007A20172027
20402046R20552056R24122608A
2805
1,100mm1,100mm
7081B3321A
1,500mm
70843124
5,000mm
4102A4105A60186018F
7100A
Green 5mYellow 10mRed 20m
Consists of :7095A(Earthresistancetestleads)8032(Auxiliaryearthspikes)8200-03(Cordreels[3pcs])9091(Carryingcaseforcordreels)
706011102608A
1,200mm
2413F2413R
2,120mm7073
70823124
1,100mm
3124
5,200mm7083
7095A4102A4102A-H4105A4105A-H60186018F
Green 5mYellow 10mRed 20m
3021302230233321A60186018F
Line 1,000mm
3161A
Earth 1,550mm7103A/7139A2002PA2002R2003A2009R2200
1,100mm7107A
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Plug
71167115
7115 7116
Extension probe
Plug
Plug φ4
Voltage test lead set
Bananaφ4 adjuster plug Testleadswithremote control switch set(7103Aor7139A,7161A,7131B,8017,9120 or 9041)
photo : 7115
photo : 7123
Plug φ4
Plug φ4
Plug φ4Plug φ4
Plug φ4
Plug φ4photo : 7149A
ACCESSORIES
www.kew-ltd.co.jp
AC
CES
SOR
IES
69
7115/7116 1,000mm
3021302230233321A60186018F
3161A
7121B4118A5406A60506201A6202
1,500mm
7122B 1,220mm
3005A3007A3131A3132A
6010A6010B6011A
Distribution board test leads
Plug
71247123 71267125
7123:(AU)Australianplug7124 : (UK)Britishplug(13A)
7125 (EU)
7123 (AU)
7123/7124/7125/7126 1,500mm
6202
6201A
4118A5406A6050
Molded plug test lead
7127A4102A4102A-H4105A4105A-H
1,570mm 7129A
7132A(KSLP5)
54106201A6202
6011A 6010A6010B6011A
1,450mm
1,500mm7133B(OMA DIEC)
7141B6310
3,000mm1,200mm
Simplified measurement probe7128A
5410
1,390mm
7146 190mm 7149A/7150A8121812281238124812581268127
8128814181428143814681478148
Line 1,000mm
7149A 7150A
3021302230233321A60186018F
3161A
Earth 1,550mm
7149A
Plug φ4
7150A
7125 : (EU)EuropeanSHUKOplug7126 : (SA) South African plug
Plugφ4
Plugφ4
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Plug φ4
Plug φ4
Plug φ4
ACCESSORIES
AC
CESSO
RIES
70
7153B 7154B 7155B
7158B7157B
1,220mm1,220mmSafety test leadsSafety test leads
1009101110121110201720272040
2046R20552056R24122608A2805
10091011101211102017202720402046R2055
2056R24122608A2805316531666010A6010B6016
7153B7154B
7155B7156B
7153B7154B
Plugφ4
7156B 1,220mmSafety test leads with fuse
10091011101211102017202720402046R2055
2056R24122608A2805316531666010A6010B6016
Line probe with alligator clip
3,000mm7168A3121A3122A3123A31253126
7165A 3,000mm
3121A3122A3123A31253126
Line probe
7159B 1,220mmSafety test leads with fuse
100910111112111020172027203720402046R2055
2056R24122608A2805316531666010A6010B6016
Distribution board fused test leads
7188A 1,520mm
6016
Extension cable
7185 3,000mm
8121812281238124812581268127
8128814181428143814681478148
Power cord
7170312863056310
2,000mm
7210A 1,040mm
1109S
Output cable
71998129
1,000mmTestleadswithremote control switch
7196A6016
1,550mm
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Plug
7222A
7218A7187A
7221A
Main test lead
31283121A3122A3123A312531263128
41066016
Guard cord Line probe
Line probe with alligator clip
Applicable model
Applicable model
Plug φ4photo : 7218A
Plug φ4
Plug φ4Plug φ4
Plug φ4
photo : 7253Plug φ4
Plug φ4
Plug φ4
photo : 7246
ACCESSORIES
www.kew-ltd.co.jp
AC
CES
SOR
IES
71
7187A/7218A/7221A/7222A 1,230mm
41406016
7187A : UKplug7218A : EUplug7221A : SA plug7222A : AUplug
7220A1051105210611062
7225A 1,500mm 7226A 3,000mm
7227A 7228A 7229A3,000mm
7246/7247
3128
4140
Earth resistance test leads Earth resistance test leads
Green : 20mYellow : 20mBlack : 20mRed : 40m
Black, Green,Red
Blue, Green, Red
Green : 5mYellow : 10mRed : 20m
Distribution board test lead
Earth cord
7224A 1,500mm
3121A3122A3123A312531263128
7238A723441061009
10111012
1051105210611062
Simplified measurement test leads
Alligator clip
1,570mm 1,400mm1,080mm
1,080mm
7246
7247
4300
2,000mm 7253/72547248Longer line probe with alligator clip
15m
7253 7254
31283121A3122A3123A31253126
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Applicable model
Temperatureprobe
Temperatureprobe
Fuse [0.5A/250V]
Ceramic fuse [0.8A/600V] Fuse [0.5A/600V]
Plug φ4
Plug φ4 Plug φ4 Plug φ4
Plug φ4
ACCESSORIES
AC
CESSO
RIES
Testleadwith IEC connector
Plug
UKAU
SAEU
AU : Australian plugUK : Britishplug(13A)EU : EuropeanSHUKOplugSA : South African plug
72
7256
8406
KAMP10
8918
8926
1,200mm
1,380mm
1,500mm
2500
1051105210611062
10111012
1051105210611062
8216
8407
8919
8927
1,000mm
1,540mm
1011 2046R2056R
1051105210611062
6010A6010B6011A
100910111012
1051105210611062
8405
8408
8901
8923
1051105210611062
1051105210611062
2805
100911102608A3005A3007A3021302230233131A3132A
1,400mm
1,540mm
TemperatureprobeOut put cord
TemperatureprobeTemperatureprobe
Ceramic fuse [10A/600V]
Fuse [10A/1000V]Fuse [440mA/1000V]
•Max. 500°C,Surfacetype,Point material: Ceramic
•Max. 600°C,Air,Gas•Max. 500°C,Surfacetype •Max. 700°C,Liquid,Semi-solid
INSTRUMENT GLOSSARY
www.kew-ltd.co.jp
INST
RU
MEN
T G
LOSS
AR
Y
73
Accuracy
The accuracy of a digital tester is defined as the difference between the reading and the true value for a quantity measured in reference conditions. Accuracy is specified in the format: (±xx% rdg ±xx dgt)
The first portion identifies a percentage error relative to the reading, which means it is proportional to the input. The second portion is an error, in digits, that is constant regardless of the input. "Rdg"is for reading and "dgt"is for digits. Dgt indicates the counts on the last significant digit of the digital display and is typically used to represent an error factor of a digital tester.
Auto-discharge Function
A function used immediately after an insulation test to automatically release charges stored within the circuit under test during measurement. Voltage remaining in the circuit under test can be monitored during auto-discharging process as the scale reading.
Auto-ranging
A function of a tester to automatically select the appropriate measuring range based on the input signal.
Average Value
The average of an AC waveform's instantaneous values taken over a half cycle. Ordinary testers respond to the average value.
For sinusoidal wave :Average value = Maximum value×2/π= Maximum value×0.637
When the true RMS value is 100V ;Average value= Maximum value×2/π=141×0.637 = 90(V)The reading of ordinary testers is calibrated in terms of the effective value of a sinusoidal wave even though they are responding to the average value. They are called average-responding-RMS-calibrated type of testers. As opposed to these, true-RMS type testers respond and show the true RMS value.
Crest Factor
The ratio of the maximum value to the effective value.It represents the range of input in which a tester maintains linear operation, expressed by a multiple of the full scale value of the range being used. Crest factor = Maximum value/True RMS valueFor sinusoidal wave;Crest factor = 141/100 = 1.41
Data Hold
A function to freeze the reading on a digital display for ease of checking or recording even in a difficult-to-read situation for a tester.
Decibel: dB
A unit used to express the magnitude of change in level of electric signal or sound intensity. A voltage ratio of 1 to 10 is equal to -20dB, 10 to 1 to 20dB, 100 to 1 to 40dB and 1000 to 1 to 60dB. A power ratio of 10 to 1 is not 20dB, but 10dB, since power(P) is proportional to the square of voltage(V).
Diode Test
A function to apply a diode or a transistor a constant current having a value needed to turn it on in order to check the diode's or the transistor's forward voltage drop and identifying the connection direction of the device.
Distortion Factor
A degree of distortion of a waveform, typically expressed as the ratio of the effective value of harmonic components to the effective value of the fundamental component.
Dual Integration Method
A technique to convert voltage into time. The first integration time (Ts) and the second integration time (Tx) are used. First, the input voltage (Vx) is integrated on a certain time interval (Ts) and then, the resulting voltage is "reverse-integrated" using a reference voltage (Vr) until it becomes 0 (zero).
The "reverse-integration time" (Tx) is proportional to input voltage (Vx). Therefore, the input voltage (Vx) can be determined by measuring Tx.
With this technique, stable measurements can be taken with high accuracy, resolution and noise rejection ratio. One particular advantage is high noise rejection ratio at 50 or 60Hz power line frequency. All of Kyoritsu digital clamp meters and testers utilize this method.
Effective Measuring Range of Insulation Tester
The measuring range for which the accuracy of an insulation tester is guaranteed. There are two kinds of effective measuring ranges: the first and second effective measuring ranges.
First effective measuring rangeFrom 1/1000 to 1/2 the maximum effective scale value(When there is no major scale division for 1/2 the maximum effective scale value, the nearest major scale division is used.)
Second effective measuring rangeScales divisions not included in the first effective measuring rangeFor example for a 500V/100MΩ insulation tester; First effective measuring range: 0.1-50MΩ(±5% of indicated value)Second effective measuring range: 50-100MΩ(±10% of indicated value)
Form Factor
The ratio of the effective value to the average value. Form factor = Effective value/Average value
Frequency Response
The manner in which a device changes its output quantity it, its indication for a measured quantity or its response over a range of frequencies. AC signals to measure with a tester can be of one frequency or from a wide frequency band ranging from low to high frequencies. To measure these frequencies, it is better to use a tester having a wide frequency response range.
Hall Element
When a current-carrying conductor is placed in a magnetic field so that the direction of the magnetic field is perpendicular
Incoming wire
Interior wiring
Transformer
Socket
Measurement categories(Over-voltage categories)
To ensure safe operation of measuring instruments, IEC61010-1 establishes safety standards for various electrical environments, categorized as CAT.1 to CAT.4, and called measurement cate-gories.Higher-numbered categories correspond to electrical environments with greater transient ener-gy (that can be very dangerous), so a measuring instrument designed for CAT.4 environments can endure greater transient energy than one designed for CAT.3 or lower.
CAT.1 : Secondary electrical circuits connected to an outlet through a transformer or similar device. Sec-ondary electrical circuit parts inside equipments like TVs, PCs, Copiers, etc.
CAT.2 : Primary electrical circuits or equipments connected to an outlet by a power cord. Outlets at more than 10 meters from CAT.3source, or at more than 20 meters from CAT.4 source.
CAT.3 : Primary electrical circuits of the equipment connected directly to the distribution panel. Switch-boards, busbars and feeders from the distribution panel to outlets.
CAT.4 : The circuit from the service drop to the service entrance, and to the power meter and primary over current protection device (distribution panel). Circuits close to the secondary side of low voltage power transformer.
INSTRUMENT GLOSSARY
INSTR
UM
ENT G
LOSSA
RY
74
to the direction of the current flow, voltage is developed in the direction perpendicular to both the magnetic field and the cur-rent flow. This is called the Hall effect and the Hall element is a device that utilizes the effect. Kyoritsu AC/DC clamp meters and clamp sensors employ the Hall element.
Harmonics
Power line AC voltage from a utility company has near sinu-soidal waveform of fundamental frequency with little distor-tion. When only a load consisting of resisters, capacitors and coils, called a linear load (its constant is fixed regardless of the amount of current flowing through it), is connected to mains supply, no distortion is introduced into the load current wave-form. However, when a non-linear load, such as a semiconduc-tor and a saturable reactor, is connected, distortion appears in the load current waveform. The current with a waveform containing distortion, or harmonic current, flows in the direction toward the low impedance side and in the process, produces voltage drop over the impedance of the current path, causing the load voltage also to contain harmonics.
Indicated Value
The value indicated by a tester for a measured quantity
Peak Hold
A function to memorize the peak value over a certain period of time.*Response time is selectable from approx. 10ms and 100ms. Reading in the peak hold mode is the peak current value multi-plies by 1/ 2. (When the input is sinusoidal, the reading is equal to the true RMS value.)
Peak Value
The value at a point where a waveform has the maximum amplitude.
Resolution
The minimum increments in which a tester can take measurements.
Sample Rate
Frequency at which an A/D converter circuit senses the quantity to measure: typically, twice or three times per second.
Sensitivity
The ability of a tester to respond to the quantity to measure, expressed as the ratio of a change induced in the reading to a change in the input:
Sensitivity = Change in reading Change in quantity to measure
Shock Hazard
Also referred to as electric shock. When a person touches a motor that has a "leak", a path can be created from the motor frame to the hand, body and feet of the person to the floor he is standing on to allow a current to flow through it, sometimes resulting in a fatal accident.The seriousness of a shock hazard widely varies depending on the amount and duration of the current that flows through the person' s body. His constitution, age and medical condition are also variation factors, but in general, at a frequency of 50 or 60Hz, stimulus to the skin is felt at 1mA, considerable pain occurs at 5mA, pain is unbearable at 10mA, there is difficulty in releasing the "leaking" object because of intense muscle contraction at 20mA, it is considerably dangerous at 50mA and fatality is likely at 100mA. For the safety limit for a fatal current, which causes ventricular fibrillation, Professor Dalziel proposed the following equation from numbers of experiments on animals. I = 165 t Where, I = current (mA) and t = time (sec). From this theory, the maximum duration for a current of 165mA is 1 second.
Thermocouple
A device that uses the voltage developed by the junction of two dissimilar metals to measure temperature. One junction, called the measuring junction, is placed at the point where tempera-ture is to be measured. The other junction, called the reference junction, is maintained at a reference temperature. The voltage developed between the two junctions varies depending on the difference between the temperatures of the two junctions and the type of thermocouple.
True RMS Value
The square root of the average of the square of a periodic wave-form's instantaneous values taken over one cycle. It is also called the rms value and the most closely relates to such form of energy as force and heat. (The effective value of an alternating current is expressed as the value of the direct current which produces the same amount of heat as the alternation current does.)
For sinusoidal wave : True RMS = Maximum value×1/ 2= Maximum value×0.707
WhenaTrueRMSis100V;Maximum value = True RMS× 2= 100×1.41 = 141(V)
TRUE RMS CAT. $600V DC/AC V DC/AC A
Measurement of AC voltage and current in True RMS value.
Measurement category part of the International safety standard IEC 61010-1
DC and AC voltage measurements DC and AC current measurements
DC Voltage AC Voltage DC+AC measurement MAX MIN AVG
DC voltage measurement AC voltage measurement AC measurement also in the pres-ence of superimposed DC compo-nent.
Function to read the maximum, minimum and average values un-der testing.
MAX MIN Resistance Continuity buzzer Diode
Function to read the maximum and minimum values under test-ing.
Resistance measurement Continuity buzzer Diode and semiconductor test measuring the forward voltage.
Capacitance Temperature Frequency Decibel
Capacitance measurement Temperature measurement by a temperature probe.
Frequency measurement Function to perform logarithmic calculations on AC voltage. The most frequent use of dB is for ex-pressing the gain of an amplifier.
Duty cycle ratio Back light Water proof Peak hold
Duty cycle is the proportion of time during which a component, device or system is operated. Duty cycle ratio is displayed in percentage (%).
Back light display for easy reading in the dark.
Water proof structure which allows use in wet places.
Function to measure the peak value like inrush current.
Data hold Auto power off Auto power save Output
Function to hold measurements on the display.
Automatic function to switch pow-er off after a period of time.
Automatic function to switch the display off after a period of time.
Output terminal for a recorder.
Filter Relative External power supply USB
Function to select the measure-ments with or without harmonics.
Function to zero the reading and to display the relative value.
Power supply from an external power source is possible.
USB connection for data commu-nication with a PC.
Low power Ω Bluetooth
Function to test resistors on a circuit board without unsoldering them using low test voltage.
Bluetooth connection for data communication with the Android devices.
DC+AC MAX/MINAVG
MAX/MIN Ω
°C Hz dB
DUTY WP PEAKHOLD
DATAHOLD
SYMBOLS
www.kew-ltd.co.jp
SYM
BO
LS
75
CAT.$600V
DCAC V DC
AC A
DC V AC V
AUTO POWEROFF
AUTO POWERSAVE
OUTPUT
Filter REL ExternalPower Supply USB
LP-Ω Bluetooth
7000
6000
3000
5000
4000
1000
2000
PRODUCT INDEX
PR
OD
UC
T IND
EX
76
1009 Digital Multimeter 11
1011 Digital Multimeter 11
1012 Digital Multimeter 11
1018 Digital Multimeter (Soft case type) 12
1018H Digital Multimeter (Hard case type) 12
1030 Digital Multimeter (Pen type) 12
1051 Digital Multimeter 14
1052 Digital Multimeter 14
1061 Digital Multimeter 14
1062 Digital Multimeter 14
1109S Analogue Multimeter 10
1110 Analogue Multimeter 10
2000 Digital Multimeter 13
2001 Digital Multimeter 13
2002PA Digital Clamp Meter 20
2002R Digital Clamp Meter 20
2003A Digital Clamp Meter 22
2007A Digital Clamp Meter 19
2009R Digital Clamp Meter 22
2010 Digital Clamp Meter 22
2012R Digital Multimeter 13
2017 Digital Clamp Meter 20
2027 Digital Clamp Meter 20
2031 Digital Clamp Meter 21
2033 Digital Clamp Meter 23
2040 Digital Clamp Meter 21
2046R Digital Clamp Meter 23
2055 Digital Clamp Meter 23
2056R Digital Clamp Meter 23
2200 Digital Clamp Meter 21
2300R Fork Current Tester 24
2412 Leakage Clamp Meter 26
2413F Leakage Clamp Meter 26
2413R Leakage Clamp Meter 26
2431 Leakage Clamp Meter 25
2432 Leakage Clamp Meter 25
2433 Leakage Clamp Meter 25
2433R Leakage Clamp Meter 25
2434 Leakage Clamp Meter 26
2500 DC Milliamp Clamp Meter 24
2608A Analogue Clamp Meter 19
2805 Analogue Clamp Meter 19
3001B Digital Insulation/Continuity Tester 30
3005A Digital Insulation/Continuity Tester 30
3007A Digital Insulation/Continuity Tester 30
3021 Digital Insulation/Continuity Tester 31
3022 Digital Insulation/Continuity Tester 31
3023 Digital Insulation/Continuity Tester 31
3131A Analogue Insulation/Continuity Tester 32
3132A Analogue Insulation/Continuity Tester 32
3161A Analogue Insulation/Continuity Tester 33
3165 Analogue Insulation Tester 33
3166 Analogue Insulation Tester 33
3321A Analogue Insulation Tester 33
3121A High Voltage Insulation Tester 34
3122A High Voltage Insulation Tester 34
3123A High Voltage Insulation Tester 34
3124 High Voltage Insulation Tester 34
3125 High Voltage Insulation Tester 35
3126 High Voltage Insulation Tester 35
3128 High Voltage Insulation Tester 36
4102A Earth Tester (Soft case model) 39
4102A-H Earth Tester (Hard case model) 39
4105A Earth Tester (Soft case model) 39
4105A-H Earth Tester (Hard case model) 39
4106 Earth Tester 40
4200 Earth Clamp Tester 41
4202 Earth Clamp Tester 41
4300 Simplified Earth Tester 40
4118A LOOP/PSC Tester 42
4140 LOOP/PFC/PSC Tester 43
5001 Leak Logger (Long life type) 46
5010 AC Current Logger 48
5020 AC Current/Voltage Logger 48
5201 Digital Illuminometer 64
5202 Digital Light Meter 64
5402D RCD Tester 44
5406A RCD Tester 44
5410 RCD Tester 45
5510 Infrared Thermometer 64
6010A Multi Function Tester 51
6010B Multi Function Tester 50
6011A Multi Function Tester 51
6016 Multi Function Tester 52
6018 Multi Function Tester 54
6050 Multi Function Tester 54
6201A Portable Appliance Tester 55
6202 Portable Appliance Tester 55
6305 Power Meter 56
6305-01 6305+8125×3 57
6310 Power Quality Analyzer 58
6310-00 6310 59
6310-01 6310+8125×3 59
6310-02 6310+8125×2 59
6310-03 6310+8124×3 59
6310-04 6310+8124×2 59
6310-05 6310+8126×3 59
6310-06 6310+8126×2 59
6310-07 6310+8127×3 59
6310-08 6310+8127×2 59
6310-09 6310+8128×3 59
6310-10 6310+8128×2 59
6310-11 6310+8129-03×1 59
6310-12 6310+8129-02×1 59
7019 Test leads 44,68
7025 Test leads 30,33,68
7060 Temperature probe 10,19,68
7066A Test leads 10,11,19~21,23,26,66,68
7067 Test leads 19,68
7073 2WAY Output cord 26,68
7081B Guard cord 33,68
7082 Leads for recorder 34,68
7083 Leads for battery charging 34,68
7084 Earth and guard leads 34,68
7095A Earth resistance test leads 39,68
7100A Precision measurement cord set 39,54,68
7103A Test leads with remote control switch 31,54,68
8000
PRODUCT INDEX
www.kew-ltd.co.jp
PR
OD
UC
T IN
DEX
77
7107A Test leads 20~22,68
7115 Extension probe 31,33,69
7116 Extension probe 31,33,69
7121B Distribution board test leads 42,44,54,55,69
7122B Test leads 30,32,50,51,69
7123 Molded plug test lead [AU] 42,44,54,55,69
7124 Molded plug test lead [UK] 42,44,54,69
7125 Molded plug test lead [EU] 42,44,54,55,69
7126 Molded plug test lead [SA] 42,44,54,69
7127A Simplified measurement probe 39,69
7128A Test leads 45,69
7129A Test lead with alligator clip 45,55,69
7131B Safety crocodile clip [black] 31,54
7132A(KSLP5) External earth probe 51,69
7133B(OMA DIEC) Distribution board test leads 50,51,69
7139A Test leads with remote control switch 31,68
7140 Adaptor for extension cord 55
7141B Voltage test lead set 56~59,69
7146 Banana φ4 adjuster plug 15,61~63,69
7148 USB cable 46,48,56~59
7149A Test leads with remote control switch set 31,33,69
7150A Test leads with remote control switch set 31,33,69
7153B Safety test leads 70
7154B Safety test leads 70
7155B Safety test leads with fuse 70
7156B Safety test leads with fuse 70
7157B Safety crocodile clips 70
7158B Safety crocodile clips for fuse 70
7159B Safety test leads with fuse 70
7161A Flat test prod [black] 31,54,55
7165A Line probe 34,35,70
7168A Line probe with alligator clip 35,70
7170 Power cord 36,56~59,70
7185 Extension cable 46,48,61~63,70
7187A Main test lead [UK] 43,53,71
7188A Distribution board fused test leads 53,70
7196A Test leads with remote control switch 53,70
7199 Output cable 61,70
7210A Test leads 10,70
7218A Main test lead [EU] 43,53,71
7220A Test leads 14,71
7221A Main test lead [SA] 43,53,71
7222A Main test lead [AU] 43,53,71
7224A Earth cord 34~36,71
7225A Guard cord 34~36,71
7226A Line probe 36,71
7227A Line probe with alligator clip 36,71
7228A Earth resistance test leads 53,71
7229A Earth resistance test leads 40,71
7234 Alligator clip 15,71
7238A Simplified measurement test leads 40,71
7246 Distribution board test lead 43,71
7247 Distribution board test lead 43,71
7248 Test leads 40,71
7253 Longer line probe with alligator clip 34,35,71
7254 Longer line probe with alligator clip 36,37,71
7256 Output cord 22,24,26,72
8008 Multi-Tran 19~23,25~27
8016 Hook type prod 31,33,54
8017 Extension prod 31,40,45,54
8019 Hook type prod 34,35
8022 AC adaptor [110V] 22,26
8023 AC adaptor [220V] 22,26
8025 Output plug 26
8029 Extension prod 36
8030 Phase indicator 65
8031 Phase indicator 65
8031F Phase indicator 65
8032 Auxiliary earth spikes [2 spikes/set] × 1set 39,40,53,68
8035 Non-contact Phase Indicator 65
8072 CAT. Ⅱ Standard prod 40
8075 Battery charger [120V] 34
8080 Battery charger [220V] 34
8112 AC Clamp Adaptor 27
8112BNC AC Clamp Adaptor 27
8115 Clamp Sensor 15,27,63
8121 Load current Clamp Sensor 15,48,60,62
8122 Load current Clamp Sensor 15,48,60,62
8123 Load current Clamp Sensor 15,48,60,62
8124 Load current Clamp Sensor 56~61
8125 Load current Clamp Sensor 56~61
8126 Load current Clamp Sensor 56~61
8127 Load current Clamp Sensor 56~61
8128 Load current Clamp Sensor 56~61
8129 Flexible Clamp Sensor 48,56~61
8141 Leakage current Clamp Sensor 46,47,58,60,63
8142 Leakage current Clamp Sensor 46,47,58,60,63
8143 Leakage current Clamp Sensor 46,47,58,60,63
8146 Leakage & Load current Clamp Sensor 15,48,58,60,62
8147 Leakage & Load current Clamp Sensor 15,48,58,60,62
8148 Leakage & Load current Clamp Sensor 15,48,58,60,62
8200-03 Cord reel [3pcs] 39
8200-04 Cord reel [4pcs] 40
8201 Output plug 20,22
8212-RS232C RS232C adaptor with “KEW Report(Software)” 40,50,53,54
8212-USB USB adaptor with “KEW Report(Software)” 37,40,50,53,54
8212-USB-W USB adaptor with “KEW Windows(Software)” 36,37
8216 Temperature probe 11,23,72
8241 USB Communication set 15
8243 Printer Communication set 15
8246 Printer 15
8247 Thermal paper for printer 15
8248 AC adapter for printer [EU] 15
8249 DMM printer full set 15
8253 CAT. Ⅲ Standard prod 40
8255 CAT. Ⅳ Standard prod 36
8302 Adaptor for recorder 35
8304 Resister for operation check 41
8307 Compact flash card [128MB] 58,59
8309 Voltage sensor 48,60
8312 Power supply adaptor 56~58,60
8319 CF card reader 58,59
8320 AC adaptor 48,60
8322 Compact flash card [256MB] 58
8323 Compact flash card [1GB] 58
8324 Adaptor for recorder 34
8325F Flicker sensor 58,59,60
8326-02 SD card [2GB] 56,57
8405 Temperature probe 15,72
8406 Temperature probe 15,72
8407 Temperature probe 15,72
8408 Temperature probe 15,72
8901 Fuse [0.5A/250V] 10,19,72
8918 Ceramic fuse [0.8A/600V] 11,72
8919 Ceramic fuse [10A/600V] 11,72
8923 Fuse [F500mA/600V] 10,11,19,30~32,72
8926 Fuse [440mA/1000V] 14,72
8927 Fuse [10A/1000V] 14,72
9000
PRODUCT INDEX
PR
OD
UC
T IND
EX
78
9029 Carrying case 65
9041 Cord case 31
9045 Cord case 44
9050 Carrying case 30
9056 Carrying case 27
9057 Carrying case 27
9070 Carrying case 65
9071 Carrying case 22
9072 Carrying case 26
9074 Cord case 30,32,33
9079 Carrying case 20
9084 Soft case 39
9089 Carrying case 31,33
9090 Carrying case 21,23,25
9091 Carrying case for cord reels 39
9092 Cord case 50,51,54
9094 Carrying case 20~23,26,61~63,65
9095 Carrying case 61~63
9096 Carrying case 24,65
9097 Carrying case 19,25,26
9103 Carrying case 10
9107 Soft case 13
9112 Carrying case [Hard] 34
9113 Carrying case 24
9114 Carrying case [Hard] 12
9115 Carrying case [Soft] 12
9118 Carrying case [Soft] 46,48
9120 Cord case 31
9121 Shoulder strap 30~33,39,40,42,44,45,51,53~55
9123 Shoulder strap 33
9125 Carrying case 40,56~59
9130 Carrying case 12
9132 Carrying case with magnet 56~58,60
9135 Carrying case 46~48,60
9137 Carrying case 61
9142 Carrying case 53
9144 Carrying case 19
9147 Cord case 42,44,45,54,55
9148 Shoulder strap 50,51
9154 Carrying case 15
9155 Shoulder strap 43
9156 Soft case 43
9158 Carrying case [Hard] 34
9159 Carrying case [Hard] 35
9160 Carrying case 21
9161 Carrying case 40
9164 Carrying case [Hard] 39
9165 Carrying case [Hard] 39
9166 Carrying case [Hard] 41
9167 Carrying case [Hard] 41
9168 Carrying case 10
KAMP10 Test lead with IEC connector 50,51,72
KT170 Voltage Tester 67
KT171 Voltage Tester 67
KT200 Digital Clamp Meter 66
KT203 Digital Clamp Meter 66
Ni-Cd rechargeable battery 34
CE Marking:signifies conformance to EMC directive(89/336/EEC,92/31/EEC,93/68/EEC or 2004/108/EC)and Low Voltage directive(2006/95/EC)
Calibration System for Electrical Measuring Instruments
National Institute of Standardsand Technology (NIST)
National Institute of Advanced Industrial Scienceand Technology (AIST)
Japan Electric MetersInspection Corporation (JEMIC)
Precision Calibrator
AC standard voltageand current generator
Instruments used in design & development,production, inspection and service departments.
DC standard voltageand current generator
Precision multimeters
Precision Calibrator
Calibration resisters
Standard resisters
QUALITY CONTROL CONCEPT
www.kew-ltd.co.jp
QU
ALI
TY
CO
NTR
OL
CO
NC
EPT
79
Kyoritsu started early an effort to establish system that ensures traceability to the national standards in order to produce reliable instruments as well as instruments that can assure reliability of other equipment and installations.
When traceability is in place, measurements taken with an in-strument any time and anywhere in any situation can be related to the appropriate national measurement standards through a clear and unbroken chain of comparisons.
For example, in terms on measurement defined by JIS (Japa-nese Industrial Standards), traceability is specified as a condi-tion in which a calibration path is established from instruments produced or in-house standards to higher level standards to the national standards. Kyoritsu currently has a system in place as shown in the figure below.
Our calibrator (standard) is calibrated at Japan Electric Meters Inspection Corporation (JEMIC), Japan Quality Assurance Orga-nization (JQA) and Fluke Japan who perform calibration based on the units established and maintained by National Institute of Advanced Industrial Science and Technology (AIST). The stan-dard is used as the in-house standard to calibrate all the test and measuring equipments which are used in-house.
Voltage : Precision calibrators are used as in-house DC and AC voltage standards.
Current : DC or AC current is converted to a voltage by a standard resistor, and the voltage is calibrated with a precision digital multimeter.
Resistance : Calibration resisters are calibrated with a DC stan-dard current generator and the precision digital multimeter.
For inquires or orders :
Safety Warnings :Please read the "Safety Warnings" in the instruction manual supplied with the instrument thoroughly and completely for correct use. Failure to follow the safety rules can cause fire, trouble, electrical shock, etc. Therefore, make sure to operate the instrument on a correct power supply and voltage rating marked on each instrument.
The contents of this leaflet are subject to change without notice.In consideration of the environment, soy ink and recycled paper were used in this publication. GeneCata13-14_1E May 13 AD
China
Japan
Thailand
Headquarters
Affiliates
U.K. Italy
KYORITSU GLOBAL NETWORK
Kew (Thailand) Ltd.
Navanakorn Industrial Estate60/48, Moo 19,Klongluang,Pathumthani, 12120 ThailandPhone: +66-2-529-0542~4 FAX: +66-2-529-0541
Kewtech Corporation Ltd.
Midas House, Unit 2b Stones Courtyard, High Street, Chesham, Buckinghamshire, HP5 1DE, EnglandPhone: +44-1494-792212 FAX: +44-1494-791826
Kew Europe Office
Viale Rimembranze 93/18, 20099 Sesto S. Giovanni (MI) ItalyPhone: +39-02-38238685
KYORITSU SHANGHAI TRADING COMPANY LIMITED
Room1303, No.58 Yan'an East Road,Huangpu District, Shanghai 200002, ChinaPhone: +86-21-6321-8899 FAX: +86-21-5015-2015URL: http://www.kew-ltd.com.cnE-mail: [email protected]
KYORITSU ELECTRICAL INSTRUMENTS WORKS, LTD.
No.5-20, Nakane 2-chome, Meguro-ku, Tokyo, 152-0031 JapanPhone: +81-3-3723-0131FAX: +81-3-3723-0152URL: http://www.kew-ltd.co.jpE-mail: [email protected]: Ehime
Test and Measuring Instruments Catalogue 2013~14
Cat
alo
gu
e 2013~14